![]() |
|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
1/5 VSCP-600 Series Switching Power Supply Rev 7-2007 Features *Current Sharing capability *Programmable Output Voltage *Universal AC Input *Short Circuit, overload, over voltage, over temperature protected *Forced air cooling by built-in DC fan *Power Failure Signal *Built-in Remote Sense *Built-in Remote Inhibit *2 year warranty Output Current Model VSCP-600-05 VSCP-600-09 VSCP-600-12 VSCP-600-15 VSCP-600-18 VSCP-600-24 VSCP-600-36 VSCP-600-48 VSCP-600-60 Output 1 5V 9V 12 V 15 V 18 V 24 V 36 V 48 V 60 V Minimum 0A 0A 0A 0A 0A 0A 0A 0A 0A Maximum 2 80/100 A 44/66 A 33/50 A 26/40 A 22/33.3 A 16/25 A 11/16.6 A 8/12 A 6/10 A Max. Power 500 W 600 W 600 W 600 W 600 W 600 W 600 W 600 W 600 W Ripple & Noise 3 Regulation <1% <1% <1% <1% <1% <1% <1% <1% <1% (Vpp) 1% 1% 1% 1% 1% 1% 1% 1% 1% Efficiency 78% 83% 84% 85% 85% 88% 88% 89% 90% Notes: 1 Output voltage is measured at output power connector. 2 Maximum current is measured at 100-120V input / 200-240V input 3 Ripple and noise is measured from 10 KHz to 20 MHz at output terminals with 0.1 F ceramic capacitor and a 22 F electrolytic capacitor in parallel. Input Parameter Input frequency Input voltage Inrush Current Input Current Conditions/Description 100~120 / 200~240 VAC (see derating curve) (130~185 / 260~370) (VDC see derating curve) Peak measured at 230 VAC at full load, cold start at 230 VAC Min 47 100 130 Nom Max 63 240 370 60 Units Hz VAC VDC A A 3.5 V-INFINITY LLC, 20050 SW 112th Ave., Tualatin, OR 97062 1-866-372-1258 www.v-infinity.com 2/5 VSCP-600 Series Switching Power Supply Rev 7-2007 Output Parameter Hold-up time Programming Conditions/Description Full load at 230 VAC Output voltage programmable through external 0~5V control voltage on VCI. Control voltage can also be obtained from VCO via a 470 KOhm pot. See application diagrams. Voltage adjustability Typical adjustment by potentiometer 25%-100% Adjustment by 1-5Vdc external control Temp. coefficient Remote Sense Remote Inhibit Current Sharing -7.5 +7.5 % 25 Min Nom Max 12 100 Units mS % 0.04 %/C Designated as (VS+) and (VS-). Total voltage compensation for cable losses with respect to the main output. Designated as (INH), requires a low signal to inhibit the output. Designated as (PAR), use in parallel for forced current sharing function. Protection Circuit Parameter Overload Overvoltage Conditions/Description Min Nom Max Units Current limiting 3 times (1.5", 3.0", 5.0"), then intelligent auto recovery before shutdown 110 135 % General and Safety Parameter Operating temp. Operating humid. Storage temp. Storage humid. EMC Safety regulation Leakage current Min Nom 0 20% -20 10 EN55022, EN610000-4-2,3,4,5,6,8,11, EN61000-3-2-3 ENV50204 Approved to UL/cUL 1950, TUV EN60950 at 240 VAC Conditions/Description Max 50 90% 85 95% Units C RH C RH 3.5 mA Mechanical Parameter Weight Enclosure Conditions/Description 290(L) x 120(W) x 67.5(H) Min Nom 2.3 Max Units Kg mm Logic Connector Parameter Pin Assignments: Conditions/Description 1. INH - Remote On-Off / Remote Inhibit 2. GND - Return / Output Ground 3. PAR - Current Sharing / Parallel function 4. FAL - AC Fail Detect (must use 2K pull up resistor) 5. 6. 7. 8. VCO - Reference output voltage (5-10 VDC) to be used for output programming VCI - Command input voltage for output programming VS(-) - Remote Sense (-) VS(+) - Remote Sense (+) 1-866-372-1258 www.v-infinity.com V-INFINITY LLC, 20050 SW 112th Ave., Tualatin, OR 97062 3/5 VSCP-600 Series Switching Power Supply Rev 7-2007 Logic Connections V-INFINITY LLC, 20050 SW 112th Ave., Tualatin, OR 97062 1-866-372-1258 www.v-infinity.com 4/5 VSCP-600 Series Switching Power Supply Rev 7-2007 V-INFINITY LLC, 20050 SW 112th Ave., Tualatin, OR 97062 1-866-372-1258 www.v-infinity.com 5/5 VSCP-600 Series Switching Power Supply Rev 7-2007 Mechanical Drawing CONTROL PIN ASSIGMENT VS+ VS VCI FAL Output Voltage Remote Sense+ Output Voltage Remote Sense Command input voltage for output programming Power Failure detect VCO 5-10 VDC reference for output programming PAR INH Current Sharing / Parallel function Inhibit / Remote On-Off GND Return / Output Ground V-INFINITY LLC, 20050 SW 112th Ave., Tualatin, OR 97062 1-866-372-1258 www.v-infinity.com |
Price & Availability of VSCP-600
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |