  management interface the management interface for this pdu model is transitioning to a new technology platform. the new interface can be distinguished by a usb-a port (for envirosense2 modules) in place of the round?envirosense?port. for managing the units containing the round port, tripp lite recommends using the poweralert console launcher rather than a web browser. this application enables local access of the pdu using a self-contained, compatible java runtime environment version. the console launcher can be downloaded for free; click the above link or go to the management solutions / utilities page. units with the new interface work will with most current web browsers. 3.2-3.8kw single-phase ats/switched pdu, lx platform interface, 200-240v outlets (8 c13 & 2 c19), 2 c20, 12ft cord, 1u rack-mount, taa model number: PDUMH20HVATNET description tripp lite switched ats / auto transfer switch provides a redundant power option for single-corded network devices. dual input cords support separate connection to primary and secondary power sources. the ats will normally maintain continuous output to all outlets as derived from the primary input cable. if the primary power source becomes unstable or fails altogether, the ats will switch over to the secondary power source until the primary input is restored and stable. switched pdu features include individually controllable output receptacles and built-in network interface. super-fast switchover between primary and secondary power sources occurs within milliseconds. ats functionality is supported by any two compatible ac power sources, regardless of phase angle, to support a variety of advanced redundant power networking applications. enables fault tolerant hot-swappable ups protection when used with a single ups and fully redundant ups protection when each cord is connected to a separate ups system. in a two-ups environment, the primary input cable must be supported by a full time sine wave ups with zero transfer time. tripp lite smartonline series is highly recommended for use as the primary ups in a two-ups application. ats configurations utilizing separate mains circuits, backup generators and even separate utility power grid feeds are fully supported. on-board ats processor constantly evaluates power quality on both input sources to prevent transfer to the secondary source when unavailable or of lower quality than the primary source. front input led's display primary or secondary power availability. built-in lx platform network management interface card. the java-free lx platform html5-based network interface enables full remote access for pdu status monitoring and?email notifications via secure web browser, snmp, telnet or ssh. it supports 10/100 mbps?auto-sensing for optimum communication with an ethernet network. optional?envirosense2 modules (sold separately) provide a variety of environmental monitoring?capabilities. protocols supported include http, https, smtp, snmpv1, snmpv2, snmpv3,?telnet, ssh, ftp, dhcp and ntp. features 200-240v 16/20a automatic transfer switch (ats) / switched pdu (agency de-rated to 16a l highlights single phase 16/20a 200-240v auto transfer switch / ats pdu l enables redundant a/b power option for non-redundant network devices l built-in lx platform network interface l 1u horizontal rackmount; 10 outlets (8 c13 switched / 2 c19 unswitched) l individually switched outlets, network interface and 2 digit visual current meter l taa compliant l package includes switch, metered pdu with ats support l set of 2 c19 to c20 12 ft. / 3.7m power cables l user manual with warranty information l 1 / 4
specifications continuous) enables redundant a/b power option for single-corded network devices l 2 digit display reports power consumption in amps l 1u horizontal rackmount form factor l 10 outlets (8 c13 switched / 2 c19 unswitched) l two c20 inlets for separate primary and secondary inputs; two 12 ft / 3.7m c20 input cables included l ats circuits normally maintain output sourced from the primary input cable; as primary input power fails, the ats will switch to maintain output sourced from the secondary input cable until power on the primary input is restored and stable l ats configurations enable hot-swappable ups protection when used with a single ups and redundant ups protection when each cord is connected to a separate ups system (in a two-ups environment, the primary input cable must be supported by an online ups with zero transfer time) l advanced ats configurations utilizing separate mains circuits, backup generators and separate out of phase utility power grid feeds are supported l on-board ats processor constantly evaluates power quality on both inputs to prevent transfer to the secondary source when unavailable or of lower quality than the primary source l 2-7 millisecond transfer time l switched outlets and ethernet interface supports individual outlet control on a real-time or programmable basis and user-specified alarm notification thresholds for all reported site power conditions l lx platform interface allows full remote access for power monitoring with email?notifications via secure web browser, snmp, telnet or ssh l optional envirosense2 modules (sold separately) provide a variety of environmental?monitoring capabilities l outlets are factory programmed for sequential turn-on at 250 millisecond intervals when the pdu is first energized l leds confirm power availability on both input lines and for each output receptacle l federal trade agreements act / taa compliant for gsa schedule purchases l overview upc code 037332151506 pdu type auto-transfer switch; switched output output capacity details 3.84kw (240v), 3.68kw (230v), 3.52kw (220v), 3.33kw (208v), 3.2kw (200v) / 16a total capacity; 16a max per c19 outlet; 12a (10a ce) max per c13 outlet 2 / 4
frequency compatibility 50 / 60 hz output receptacles (8) c13; (2) c19 output nominal voltage 200; 208; 220; 230; 240 overload protection n/a customized load management receptacles 8 individually switched c13 output receptacles input pdu input voltage 200; 208; 220; 230; 240 recommended electrical service 20a 208/240v; 16a 230v maximum input amps 20.0 maximum input amps details agency de-rated to 16a continuous pdu plug type (2) iec-320 c20 input cord details set of two inputs connect to separate primary and secondary power sources input cord length (ft.) 12 input cord length (m) 3.66 input phase single-phase user interface, alerts & controls front panel lcd display digital display reports total pdu output current in amps front panel leds 8 leds display power on-off status for each c13 output receptacle, plus 2 additional leds to indicate input power status for primary and secondary inputs switches toggle switch near digital display enables the setting of "hi" for 220, 230 or 240v nominal applications or "lo" for 200 or 208v applications physical minimum required rack depth (inches) 18.3 minimum required rack depth (cm) 46.48 shipping dimensions (hwd / in.) 5.40 x 20.80 x 23.40 shipping dimensions (hwd / cm) 13.72 x 52.83 x 59.44 shipping weight (lbs.) 17.90 shipping weight (kg) 8.12 unit dimensions (hwd / in.) 1.72 x 17.3 x 14.8 unit dimensions (hwd / cm) 4,4 x 43,9 x 37,6 unit weight (lbs.) 10.30 unit weight (kg) 4.67 material of construction metal 3 / 4
? 2019 tripp lite. all rights reserved. all product and company names are trademarks or registered trademarks of their respective holders. use of them does not imply any affiliation with or endorsement by them. tripp lite has a policy of continuous improvement. specifications are subject to change without notice. tripp lite uses primary and third-party agencies to test its products for compliance with standards. see a list of tripp lite's testing agencies: https://www.tripplite.com/products/product-certification-agencies form factors supported 1u rackmount pdu form factor horizontal (1u) environmental storage temperature range 5 to 122f (-15 to 50c) relative humidity 5-95% (non-condensing) operating elevation (ft.) 0-10,000 operating elevation (m) 0-3000 communications snmp compatibility pre-installed lx platform interface provides remote monitoring via java-free html5 web interface, telnet, ssh and snmp management systems certifications certifications tested to ul 60950 (usa, canada), ce (europe), class a (emissions), nom (mexico), rohs complaint, taa compliant warranty product warranty period (worldwide) 2-year limited warranty 4 / 4


▲Up To Search▲   

 
Price & Availability of PDUMH20HVATNET

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X