clamp on sensor 9650 < clamp sensors < products clamp sensors (current sensor - for the 3636 - 20 clamp logger, and 8205 - 10/8206 - 10 micro hicorder - ) clamp on sensor 9650 cat iii 300 v clamp logger 3636 - 20 overview ? clamp - on sensors for the clamp logger 3636 - 20, and micro hicorder 8205 - 10/8206 - 10 for input up to ac 500a, select our model 9651, and for smaller currents of up to ac 100a, select model 9650. both sensors are designed with a safety barrier to protect the user from being in direct contact with live conductors and completely meet all ce marking requirements. basic specifications rated input current 100 a ac rated output current 100 ma ac accuracy (at 50/60 hz) amplitude: 1.5 % rdg. 0.03 % f.s. , full scale (f.s.) is the rated input current value frequency characteristics 40 hz to 1 khz ( 8 % or less) max. allowable input continuous 130 a rms (45 to 66 hz) max. circuit voltage 300 v ac rms (insulated wire) core jaw dia. ? 15 mm(0.59 in) dimensions, mass 46 mm(1.81 in)w 135 mm(5.31 in)h 21 mm(0.83 in)d, 200 g (7.1 oz), cord length: 3 m(9.84 ft) overview ? generated by www.pdfonfly.com
clamp on sensor 9651 < clamp sensors < products clamp sensors (current sensor - for the 3636 - 20 clamp logger, and 8205 - 10/8206 - 10 micro hicorder - ) clamp on sensor 9651 cat iii 600 v clamp logger 3636 - 20 overview ? clamp - on sensors for the clamp logger 3636 - 20, and micro hicorder 8205 - 10/8206 - 10 for input up to ac 500a, select our model 9651, and for smaller currents of up to ac 100a, select model 9650. both sensors are designed with a safety barrier to protect the user from being in direct contact with live conductors and completely meet all ce marking requirements. basic specifications rated input current 500 a ac rated output current 500 ma ac accuracy (at 50/60 hz) amplitude: 1.5 % rdg. 0.03 % f.s. , full scale (f.s.) is the rated input current value frequency characteristics 40 hz to 1 khz ( 3 % or less) max. allowable input continuous 600 a rms (45 to 66 hz) max. circuit voltage 600 v ac rms (insulated wire) core jaw dia. ? 46 mm(1.81 in) dimensions, mass 77 mm(3.03 in)w 151 mm(5.94 in)h 42 mm(1.65 in)d, 340 g (12.0 oz), cord length: 3 m(9.84 ft) overview ? generated by www.pdfonfly.com
clamp on sensor 9668 < clamp sensors < products clamp sensors (current sensor - for the 3636 - 20 clamp logger, and 8205 - 10/8206 - 10 micro hicorder - ) clamp on sensor 9668 cat iii 600 v micro hicorder 8205 - 10, 8206 - 10 overview ? clamp - on sensors for micro hicorder 8205 - 10/8206 - 10 for input up to ac 1000a, select our model 9668, this sensor is designed with a safety barrier to protect the user from being in direct contact with live conductors and completely meet all ce marking requirements. basic specifications rated input current 1000 a ac rated output current 1000 ma ac accuracy (at 45 to 66 hz) amplitude: 3.0 % rdg. 0.03 % f.s. , full scale (f.s.) is the rated input current value frequency characteristics 40 hz to 1 khz ( 3 % or less) max. allowable input continuous 1000 a rms (45 to 66 hz) max. circuit voltage 600 v ac rms (insulated wire) core jaw dia. ? 55 mm(2.17 in), 80 mm (3.15 in) 20 mm (0.79 in) busbar dimensions, mass 99.5 mm(3.92 in)w 188 mm(7.40 in)h 42 mm(1.65 in)d, 550 g (19.4 oz), cord length: 3 m(9.84 ft) overview ? generated by www.pdfonfly.com
|