  temperature standards stable uniform heat sources kaye temperature references are designed for easy operation while delivering the highest level of temperature stability possible. these stable uniform heat sources combine rapid heat-up and cool- down with large sensor capacity to minimize overall calibration time. multiple calibration set points are programmed via the easy-to-use operator panel and displayed (set point or well temperature) to 0.01 degree accuracy. these references provide fully automated sensor calibration when used with kayes validator and traceable irtd temperature standard. ctr -80 cryo temperature bath ? 120 minute cool-down from ambient to =80c ? stability of 0.01c ? very low noise ? operates on standard line voltage ? mounted on casters for portability ? positions for two irtd standards a mphenol advanced sensors features htr and ltr series dry wells ? rapid response time with no oils or fuids ? stability of 0.02c (0.05c for temperatures exceeding 300c) ? lightweight yet rugged design for portability ? operates on standard line voltage ? dry well inserts minimize thermocouple tip cooling ? temperature range -95 to +140c
specifcations ctr-40 ctr-80 htr 400 ltr -25/140 ltr-40/140 ltr-90 temperature range C40c to 150c -80 to 100c (C112f to 212f) 25c above ambient to 400c C25c to 140c C40c to 140c C95c to 140c ambient operating range 5C40c (41C104f) 15 to 25c (59 to 77f) 5c to 50c 5c to 50c 5c to 50c 5c to 50c set-point accuracy 0.5c 0.006c at C80c (ethanol) 0.010c at 0c (ethanol) 0.010c at 100c (oil) 0.2c to 300c 0.3c to 400c 0.2c 0.2c 0.2c temperature stability 0.005c at C40c (ethanol) 0.005c at 25c (water) 0.007c at 150c (5012 oil) 0.006c at C80c (ethanol) 0.010c at 0c (ethanol) 0.010c at 100c (oil) 0.02c to 300c 0.05c to 400c 0.02c 0.02c 0.02c temperature uniformity 0.006c at C40c (ethanol) 0.005c at 25c (water) 0.010c at 150c (5012 oil) 0.008c at C80c (ethanol) 0.012c at 0c (ethanol) 0.012c at 100c (oil) transfer calibration accuracy* irtd standard to thermocouples 50c to 150c: 0.1c 150c to 250c: 0.2c 250c to 350c: 0.3c 350c to 400c: 0.4c C25c to 80c: 0.1c 80c to 130c: 0.15c 130c to 140c: 0.18c C40c to C25c: 0.15c C25c to 80c: 0.1c 80c to 130c: 0.15c 130c to 140c: 0.18c C40c to C25c: 0.15c C25c to 80c: 0.1c 80c to 130c: 0.15c typical heat-up time 60 minutes, from 25c to 150c (5012 oil@115v) ambient to 90c: 5 minutes 90c to 125c: 3 minutes 350c: 25 minutes ambient to 80c: 6 minutes ambient to 140c: 14 minutes ambient to 80c: 6 minutes ambient to 140c: 14 minutes ambient to 80c: 6 minutes ambient to 140c: 14 minutes typical cool-down time 110 minutes, from 25c to C40c (ethanol) 25 to -80c 120 min access opening 172mm x 94mm (6.8 x 3.7 ) 86 mm x 114 mm (3.25 x 4.5) w/positions for (2) irtds and (3) 11 mm (7/16) dia. x 203 mm (8) deep calibration wells well confguration reference wells (2): 6.7 mm diameter x 127 mm deep calibration wells (8): 9 mm diameter x 155 mm) deep reference wells (2): 6.7 mm diameter x 155 mm deep calibration wells (6): 9 mm diameter x 155 mm) deep reference wells (2): 6.7 mm diameter x 155 mm deep calibration wells (6): 9 mm diameter x 155 mm) deep reference wells (2): 6.7 mm diameter x 155 mm deep calibration wells (6): 9 mm diameter x 155 mm) deep display digital with push-button entry led w/0.01 (c or f resolution) led w/0.01c resolution led w/0.01c resolution led w/0.01c resolution led w/0.01c resolution computer interface rs-232 rs232 rs232 rs232 rs232 rs232 dimensions 305 mm x 622 mm x 584 mm (12 x 24.5 x 23) 762 x 305 x 610 mm (30 h x 12w x 24 d) 343 mm x 198 mm x 317.5 mm 343 mm x 198 mm x 317.5 mm 343 mm x 198 mm x 317.5 mm 343 mm x 198 mm x 317.5 mm weight 35.4 kg (78 lb) 57 kg (125 lbs) 8.2 kg 13.6 kg 13.6 kg 13.6 kg power 115 vac (10%), 60 hz, 15 amps [230 vac (10%), 50 hz, 8 amps optional] 115 vac 60 hz, 16a or 230 vac 50 hz, 8a 1700 watts 115 vac 60 hz, 6 a or 230 vac 50 hz, 3 a 700 watts 115 vac 60 hz, 3 a or 230 vac 50 hz, 1.5 a 350 watts 115 vac 60 hz, 3 a or 230 vac 50 hz, 1.5 a 350 watts 115 vac 60 hz, 3 a or 230 vac 50 hz, 1.5 a 350 watts fault protection over temp limits(user settable), low voltage cutout, automatic refrigeration turn off, electrical fuse sensor burnout protection, over temperature thermal cutout, electrical fuse sensor burnout protection, over temperature thermal cutout, electrical fuse sensor burnout protection, over temperature thermal cutout, electrical fuse sensor burnout protection, over temperature thermal cutout, electrical fuse * transfer calibration accuracy is the difference between the thermocouple tip and the sensor of the irtd temperature standard. this accuracy includes well to well uniformity. aas-920-630a-03/2014 www.amphenol-sensors.com ? 2014 amphenol corporation. all rights reserved. specifcations are subject to change without notice. other company names and product names used in this document are the registered trademarks or trademarks of their respective owners. a mphenol advanced sensors ctr-80 cryo temperature bath operating from -80 to 30c, the ctr delivers fast response, high stability, and automated sensor calibration for the most severe cold-temperature applications. a generous one-gallon tank is heated and cooled quickly and quietly by a two-stage refrigeration (r507 and r508b). the ctr-80 is the ideal unit for calibrating temperature sensors used in freeze dryer, freezer, and cryo unit validation. htr and ltr series dry wells the htr and ltr series dry wells are specifcally designed for calibrating sensors used for process validation. these are the most advanced reference units on the market, featuring fast heat-up and cool-down, large well capacity to accommodate 18 to wr thermocouples, and use no messy oils or fuids. the htr 400 is ideal for high-temperature applications such as autoclaves, dry heat ovens and sterilizer tunnels. the ltr models offer ultra low-temperature performance to -95c for applications including freezers, cold rooms, incubators and autoclaves. the ltr model selection should be based on the applications low-temperature point.


▲Up To Search▲   

 
Price & Availability of HTR400

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X