features rating to 1000v prv ideal for printed circuit board reliable low cost construction utilizing molded plastic technique results in inexpensive product lead tin plated copper mechanical data polarity:symbol molded on body mounting position :any maximum ratings and electrical characteristics rating at 25 ambient temperature unless otherwise specified. single phase, half wave ,60hz, resistive or inductive load. for capacitive load, derate current by 20% characteristics symbol bt05s bt1s bt2s BT4S bt6s bt8s bt10s unit maximum recurrent peak reverse voltage v rrm 50 100 200 400 600 800 1000 v maximum rms voltage v rms 35 70 140 280 420 560 700 v maximum dc blocking voltage v dc 50 100 200 400 600 800 1000 v maximum average forward rectified current (note 1) @t a =40 peak forward surge current 8.3ms single half sine-wave super imposed on rated load(jedec method) i 2 t rating for fusing (t<8.3ms) i 2 t a 2 s peak forward voltage at 0.8a dc v f v maximum dc reverse current @t j =25 at rated dc bolcking voltage @t j =125 typical junction capacitance per element (note2) c j pf typical thermal resistance (note3) r ja /w operating temperature range t j storage temperature range t stg 4.the typical data above is for reference only( ?). rev. 8, 16-mar-2016 3.7 notes:1.mounted on p.c. board. 2.measured at1.0mhz and applied reverse voltage of 4.0v dc. 1.05 i r 5 a 500 3.thermal resistance junction to ambient 15 75 -55 to +150 -55 to +150 a i fsm 30 a dimensions in inches and (millimeters) i (av) 0.8 bt05s thru bt10s surface mount glass passivated bridge rectifiers reverse voltage - 50 to 1000 volts forward current - 0.8 ampere bts .008(0.2) .030(0.75) .018(0.45) .106(2.7) .09(2.3) .197(5.0) .181(4.6) .063(1.6) .047(1.2) .157(4.0) .142(3.6) .043(1.1) .027(0.7) .276(7.0) .260(6.6) .014(.35) .006(.15) .071(1.8) .055(1.4)
rating and charactertic curves bt05s thru bt10s the curve graph is for reference only, can't be the basis for judgment( ?)! rev. 8, 16-mar-2016 1 4 10 100 100 10 1.0 reverse voltage volts capacitance( p f) fig.5-typical junction capacitance tj=25c f=1mhz average forward current amperes fig.1-forward current derating curve a mbient temperature, 1.0 0.8 0.6 0.4 0.2 0.1 20 40 60 100 120 140 80 mounted on board single phase half wave 60hz resistive or inductive load fig.2 - maximum non-repetitive surge current peak forward surge current, amperes number of cycles at 60hz 1 2 5 10 20 50 100 10 0 40 30 20 pulse width 8.3ms single half-sine-wave (jedec method) instantaneous reverse current,(a) percent of rated peak reverse voltage (%) fig.3-typical reverse characteristics 0.01 0.1 0 20 40 60 80 100 1.0 10 100 t j =75c t j =25c t j =100c t j =125c 0.01 0.1 1.0 10 0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 instantaneous forward voltage,volts instantaneous forward current,(a) fig.4-typical forward characteristics t j= 25c pulse width:300us 2% duty cycle t j =25c t j =75c t j =125c t j =100c 150
legal disclaimer notice all specifications and data are subject to be changed without notice to improve reliability function or design or other reasons. hy makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or the co- tinuing production of any product. to the maximum extent permitted by applicable law, hy disclaims (i) any and all liability arising out of the application or use of any product, (ii) any and all liability, including without limitation special,consequential or incidental d- amages, and (iii) any and all implied warranties, including warranties of fitness for particular purpose, non-infringement and merch- antability. statements regarding the suitability of products for certain types of applications are based on hy?s knowledge of typical require- ments that are often placed on hy products in generic applications. such statements are not binding statements about the suitabi- lity of products for a particular application. it is the customer?s responsibility to validate that a particular product with the properties described in the product specification is suitable for use in a particular application.parameters provided in datasheets and specific- ations may vary in different applications and performance may vary over time. all operating parameters, including typical paramet- ers, must be validated for each customer application by the customer?s technical experts. product specifications do not expand or otherwise modify hy?s terms and conditions of purchase, including but not limited to the warranty expressed therein. except as expressly indicated in writing, hy products are not designed for use in medical, life-saving, or life-sustaining applicati- ons or for any other applications in which the failure of the hy product could result in personal injury or death. customers using or selling hy products not expressly indicated for use in such applications do so at their own risk.please contact authorized hy pers- onnel to obtain written terms and conditions regarding products designed for such applications. no license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by any conduct of hy. product names and markings noted herein may be trademarks of their respective owners. ?????????? hy ???????????hy (i) ? ??????(ii) ???????(iii) ??? ???????? ????? hy ? hy ???????????? ???????????????? ????? ????????????? ??? hy ???? hy ???? ?hy ????? hy ??????? ?????? hy ????????hy ?? ? ? hy ??????????????????? ??? rev. 2, 16-mar-2017 disclaimer
|