Part Number Hot Search : 
CS51220 M5671 UPA1742 A30RCK 325012P PN0315 PN0315 MAX4655
Product Description
Full Text Search
 

To Download 2DU20 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  v-ea-series - ul508 manual motor controller - 2 pole d-trip two pole standard pack: 6 weight: 0.3a - 63a 1.68kg (3.7 lb.) 35 mm (1.38 in.) 70 mm (2.76 in.) 35 mm (1.38 in.) 91.5 mm (3.60 in.) ul508 listed e137938 v - e a - d tr i p 0.3a through 10a rated current 1.13-1.45xi n 1234568 10 20 40 100 multiple of rated current 10 -3 4x10 -3 10 -2 4x10 -2 10 -1 0.4 1 4 10 1 4 10 40 60 seconds minutes tri pping time t 16 thermal overload must tr ip < 1 hr = 145% rc must not t rip > 1 hr = 113% rc 10 -3 4x10 -3 10 -2 4x10 -2 10 -1 0.4 1 4 10 1 4 10 40 60 v - e a - d tr i p 13a through 63a rated current 12345 16 6 8 10 20 40 100 multiple of rated current seconds minutes tri pping time t thermal overload must tr ip < 1 hr = 145% rc must not t rip > 1 hr = 113% rc 1.13-1.45xi n rated type/ current cat. no. approvals 0.3a 2du03 0.5a 2du05 0.75a 2du075 0.8a na 1.0a 2du1 1.6a 2du1.6 2.0a 2du2 2.5a 2du2.5 3.0a 2du3 3.5a 2du3.5 4.0a 2du4 5.0a 2du5 6.0a 2du6 8.0a 2du8 10a 2du10 12a na 12.5a na 13a 2du13 15a 2du15 16a 2du16 20a 2DU20 25a 2du25 30a 2du30 32a 2du32 40a 2du40 50a 2du50 60a 2du60 63a 2du63 u l u l u l u l u l u l u l u l u l u l u l u l u l u l u l u l u l u l u l u l u l u l u l u l u l voltage rating short circuit withstand rating (ul/csa - ratings) group short circuit withstand rating (ul/csa - ratings) interrupting capacity (vde - ratings) calibration temperature terminal size acceptability terminal torque terminal protection degree 480y/277vac 0.3-25a: 1 pole - 42vdc; 2 pole - 80vdc 30-60a: 1 pole - 24vdc; 2 pole - 60vdc 0.3-60a (rc): 10ka with ul-listed rk5 back-up fuse or mccb 0.3-10a (rc): 10ka; 12-60a (rc): 5ka no branch circuit protection required 0.3-63a (rc): 10ka 40c (104f) top: 18-3 awg; bottom: 18-2 awg 20 lb.in. ip20 short circuit withstand ratings for v-ea manual motor controller backup ul-listed ul-listed no bcp trip protection rk5-fuse mccb required curve amp range up to 10ka up to 10ka up to: all 0.3 - 10a 4xrc* 4xrc* 10ka min 15a, max 70a min 15a, max 70a all 12 - 30/32a 4xrc* 4xrc* 5ka max 125a max 125a all 40 - 50a 4xrc* 4xrc* 5ka max 200a max 200a all 60 / 63a 4xrc* 4xrc* 5ka max 250a max 250a *up to nearest rated current for ring tongue terminal version, replace u with r in part number. for example 1br20 instead of 1bu20.
mouser electronics authorized distributor click to view pricing, inventory, delivery & lifecycle information: altech: ? 2du5l? 2du40l? 2du16l? 2du32l? 2du60l? 2du50l? 2du1l? 2du12l? 2DU20l? 2du25l? 2du8l? 2du2l? 2du4l ? 2du63l? 2du15l? 2du02l? 2du10l? 2du30l? 2du3l? 2du05l? 2du13l? 2du6l


▲Up To Search▲   

 
Price & Availability of 2DU20

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X