  p series www.cor.com - libertyville, il (847) 680-7400 p 04 the chameleon adaptable module for general or medical applications ul recognized csa certified vde approved p series the p series power entry module offers full flexibility of design in the most compact package. as the first 10 amp module to provide all five power entry functions in one compact design, the p series readily adapts to its environment and the needs of international markets. ? iec power line connector ? both north american and european fusing capabilities ? two voltage selections ? optional dpst on/off switch ? filtering options for general purpose and medical applications. the p series compact design and modular construction will allow you to select all the power entry features you require ? without altering the panel cutout. and the p series, with adapters, will fit any standard panel cutout you currently have designed with either snap-in or flange mounting. the p series is available with a variety of filtering options: o models - this version does not include an rfi filter, but has all other options of the p series. they are rated for applications up to 10 amps. s models - general purpose filter for applications where line-to-ground and line-to-line noise must be controlled. these filters allow compliance with fcc limits for linear power supplies. they are available with current ratings of 3, 6, 10 amps. h models - designed to help medical equipment meet ul544, ul2601 and en60601 for patient care equipment and non-patient care equipment, these filters provide susceptibility protection without leakage current associated with line-to-ground capacitors. they are available with current ratings of 3, 6 and 10 amps. b models - included with these unfiltered models is an interconnection block that reduces external wiring by connecting the switch with the fuse(s) and iec receptacle. they are rated for applications up to 10 amps. z models - high performance filter versions are designed to help bring most digital equipment (including switching power supplies) into compliance with en55022, level b (as well as fcc part 15j, class b) conducted emissions limits. they are available with current ratings of 6 and 10 amps. high performance versions are available with horizontal mounting ears, no extenders, single voltage, complete can shield with options for switch, fuses and current ratings only. l models - high performance medical filter versions that are designed to help bring most digital equipment (including switching power supplies) into compliance with en55022, level b (as well as fcc part 15j, class b) conducted emissions limits while additionally allowing equipment to meet ul544, ul2601 and en60601 for patient care equipment and non-patient care equipment. they are available with current ratings of 6 and 10 amps. high performance versions are available with horizontal mounting ears, single voltage, complete can shield with options for switch, fuses and current ratings only. extenders are not available. pe filtered with ?a? shield ps unfiltered ps filtered
series p www.cor.com - libertyville, il (847) 680-7400 p 105 p mounting style e = mounting ears (horizontal) s = snap-in extender options 1 0 = none c = fn260 j = j series l = l series switch options 0 = no switch s = double pole single throw (dpst) input voltage select 0 = single ac voltage s = dual ac voltage select (smps) x = dual ac voltage select (series/parallel) fuse options d = dual fuse s = single fuse shield options 2, 3 0 = no shield a = filter shield b = complete shield c = complete can (high performance version) filter current 3 0 = no filter or interconnection block 3 = 3 amps 6 = 6 amps x = 10 amps filter type 3, 4 0 = no filter b = interconnection block h = medical l = medical high performance s = general purpose z = high performance p series part number system part numbers are constructed by selecting the alphanumeric character which represents the desired feature. ordering information consult your local corcom sales representative for pricing. most popular part numbers (contact factory for availability of component combinations not listed) notes: 1 extenders cannot be added to units with b or c shields. extenders allow the p series to fit other corcom/competitor panel cutouts. 2 shields can only be used with filtered models. 3 when using interconnection block, the last 3 digits of the part number are bx0. 4 high performance versions are available with horizontal mounting ears, no extenders, single voltage, complete can shield with options for switch, fuses, filter type (l or z) and current ratings only. (e.g pe0 _ s _ _ _c) psj0xss60 no shield 6a current general purpose filter single fusing dual voltage select (series/parallel) no switch j extender snap-in mount p series mounting styles corcom offers both flange mounting as well as snap-in mounting of the popular p series. this allows oem?s to choose the part that best suits their production methods. extender option extenders are available which allow the p series to adapt to corcom?s l or j series cutouts, as well as the panel cutout of schaffner and delta parts (c extender). eg. the ?j? extender will allow the ?p? series to fit the corcom ?j? series cutout series flange mount snap-in mount filtered pe00xds60 pe0s0ss6b pe0ssss60 pe0s0dlxc pe0s0dl6c pe0s0dzxc pe0s0dz6c pe0s0slxc pe0s0sl6c pe0s0szxc pe0s0sz6c ps000d000 ps000s000 ps000sh30 ps000ss3b ps000ss60 ps000ss6b ps000ssxb ps00xd000 ps00xs000 ps0s0d000 ps0s0dbx0 ps0s0dh3b ps0s0dhx0 ps0s0ds60 ps0s0ds6a ps0s0ds6b ps0s0s000 ps0s0sbx0 ps0s0sh60 ps0s0sh6b ps0s0shxa ps0s0ss3a ps0s0ss3b ps0s0ss60 ps0s0ss6a ps0s0ssxb ps0sssh30 ps0sxd000 ps0sxdh30 ps0sxdh3a ps0sxdh60 ps0sxdh6a ps0sxds30 ps0sxds3a ps0sxds60 ps0sxds6b ps0sxs000 ps0sxsh30 ps0sxsh6a ps0sxss30 ps0sxss60 ps0sxss6a ps0sxss6b ps0sxssx0 psjs0dh30 PSJS0S000 psjsxs000 unfiltered pe0sss000 psjsxs000 PSJS0S000 psj0xd000 psj0xs000 ps0ssd000 ps0sss000 ps0sxd000 ps0sxs000 ps0s0d000 ps0s0s000 ps00sd000 ps00ss000 ps00xd000 ps00xs000 ps000d000 ps000s000
www.cor.com - libertyville, il (847) 680-7400 p 06 p series switch option both switched (dpst) and unswitched wiring of the p series are available. input voltage select the p series of power entry modules provides a dual voltage selector which is integrated with the fuseholder. to simplify the wiring in each individual application, corcom provides dedicated voltage selectors for different voltage selection schemes. the two most popular schemes are series/parallel for dual primary transformers and the ?dpst switch? for switching mode power supplies (jumper types.) p series products with an ?s? as the fifth digit are specifically designed for ?jumper? type applications associated with switching mode power supplies. filter type six options are available for the filter type: general purpose, medical applications, high performance, high performance medical as well as an unfiltered and unfiltered with an interconnection block. filtered versions include the s models which are designed for general purpose applications where line-to- ground and line-to-line noise must be controlled. z models are high performance filters designed to help bring most digital equipment (including switching power supplies) into compliance with en55022, level b (as well as fcc part 15j, class b) conducted emissions limits. h models are the medical versions of the s models and are designed to help equipment meet ul544, ul2601 and en60601 for patient and non-patient care equipment in medical applications. l models are the medical version of the z models (high performance) that are designed to additionally allow equipment to meet ul544, ul2601 and en 60601 for patient and non-patient care equipment. 1) dual primary transformer type: 2) jumper type note 1: jumpers are required if a filter or interconnection module is not used. note 2: location of optional filter. jumpers are required if a filter or interconnection module is not used. s model applications. the voltage selector installed will allow proper wiring from these applications. no matter what voltage selection scheme is used, wiring is always made to the same four terminals. fuse / fuseholder options another feature of the p series power entry module is a versatile fusing arrangement. its fuseholder can hold two 1/4? x 1-1/4? or 5 x 20mm fuses. it can also be converted to accept one fuse with a conversion clip that bridges one of the two fuse chambers. the conversion clip is installed on the p series power entry modules set for single fusing (those with part numbers with an ?s? as the sixth digit). units with a ?d? as the sixth digit do not include a conversion clip. extenders cannot be added to units with b or c shields. (voltage selection not available on l or z models) p series products with an ?x? as the fifth digit are specifically designed for dual primary transformer shown is the fuseholder with a fuse held in the proper manner. note that the back end of the fuse slightly protrudes out of the fuseholder in order to make contact with a terminal inside the power entry module.
www.cor.com - libertyville, il (847) 680-7400 p 107 minimum insertion loss in db: line-to-ground in 50 ohm circuit current frequency-mhz rating .03 .1 .15 .5 1 3 5 10 30 s models 3a 7 17 21 27 33 40 44 50 32 6a 8 12 17 23 32 36 44 30 10a 3 5 10 13 23 27 35 27 h models 3a 7 17 21 27 30 29 26 23 15 6a 8 11 15 17 19 18 16 13 10a 3 5 8 10 12 11 11 10 10 line-to-ground in 50 ohm circuit current frequency-mhz rating .01 .05 .1 .15 0.5 1 5 10 30 z models 6a 8 21 27 30 37 43 49 52 42 10a 5 17 22 24 27 32 52 47 40 l models 6a 8 21 27 29 34 35 25 21 16 10a 5 17 22 23 24 25 21 18 14 line-to-line in 50 ohm circuit current frequency-mhz rating .10 .15 .5 1 3 5 10 30 s models 3a 2 4 12 15 30 48 50 45 6a 2 4 12 15 22 42 55 45 10a 2 4 12 15 22 42 55 45 h models 3a 2 4 12 18 31 40 48 41 6a 2 4 12 16 26 35 40 35 10a 2 4 12 16 26 33 40 32 line-to-line in 50 ohm circuit current frequency-mhz rating .01 .05 .1 .15 0.5 1 5 10 30 z models 6a 10 15 34 44 75 75 75 70 60 10a 10 20 20 35 67 75 75 70 60 l models 6a 10 15 34 44 75 75 75 70 60 10a 10 20 20 35 67 75 75 70 60 series p unfiltered versions of the p series includes a standard version 0 models that does not have an rfi filter, but does have all other options of the p series. it also includes an interconnection block version b models which provides wiring of the iec socket to the switch and the switch to the fuseholder. labor can be eliminated by ordering the product with an interconnection block. this feature, designated by a ?bx0? at the end of the part number, prewires the module for easier installation. the wiring is protected with the plastic case to prevent access to the terminals and connections. wiring can be further simplified by ordering a pa100 connector assembly, as shown in the accessories section. the dimensions of this alternative are the same as the filtered versions. filter current the p series is available without a filter (10a rating) or in 3, 6 and 10 ampere filtered versions. shield options a feature available on the p series is an rf shield. the metal shield, available on filtered models, provides shielding from radiated emissions and provides an additional rf ground for the filter to the case. the shield is available in two versions, a shield of the filter components (designated by a as the ninth digit) and a complete shield (designated by b as the ninth digit). the a shield covers the filter portion of the module and increases performance of the filter by protecting the components from magnetic coupling. this shield improves rf ground connection to the case while still specifications ? filtered models h model z model l model a shield b shield allowing the use of the p series extender. the b shield covers the entire power entry module with metal, protecting the equipment from all radiated noise. the c shield is a complete can for the high performance versions used with the filter, the shield provides the most secure protection from rfi noise problems. the c shield cannot be used with any extender.
p series www.cor.com - libertyville, il (847) 680-7400 p 08 case dimensions ? unfiltered models metric shown in italics. part no. a b c d e f (max) (max) (max) pe 1.98 1.93 2.31 1.122 2.201 1.575 50.3 49.0 58.7 28.50 55.91 40.0 ps 1.24 1.93 2.31 1.060 2.201* 31.5 49.0 58.7 26.93 55.91 psc 1.24 1.93 2.81 1.060 2.520 31.5 49.0 63.8 26.92 64.01 psj 1.24 1.93 2.72 1.060 2.600+ 31.5 49.0 69.1 26.92 66.00 psl 1.24 1.93 2.31 1.120 2.201* 31.5 49.0 58.7 28.45 55.91 * panel cutout for thickness of .031 - .079 (0.8 - 2.0) . for panel thickness at .083 - .114 (2.1 - 2.9) use 2.213 (56.21). + panel cutout for thickness of 0.06 - 0.09 (0.76 - 2.29) . case styles - unfiltered models metric shown in italics. pe ps/psl psc/psj specifications ? unfiltered models hipot rating (one minute): line-to-ground 1500 vac line-to-line 1450 vdc operating frequency: 50/60 hz rated voltage: 120/250 vac rated current, all unfiltered models: 10a @ 120 vac 10a @ 250 vac operating voltages: selectable or fixed 115/230 vac fuseholder: accepts one or two fuses* 1/4? x 1-1/4? or 5 x 20 mm switch: double-insulated rated for 10,000 operations at full load. 51 amp inrush capability. terminals: 0.187? x 0.032? terminal tabs *conversion clip provided on fuseholder for single fuse models. * for snap-in applications, the d sides of the cutout must have a .02 ( .508 ) radius on the installation side. note: snap-in models allow front mounting only. ps not recommended for plastic panels. back view typical panel cutout +.008/- .000 +.20/-.00 +.008/- .000 +.20/-.00 mounting holes dia. (2) countersunk holes .125 3.18
series p www.cor.com - libertyville, il (847) 680-7400 p 109 case dimensions ? filtered models metric shown in italics. part no. a b c d e f (max) (max) (max) pe 1.98 2.13 2.31 1.120 2.201 1.575 50.3 54.1 58.7 28.45 55.91 40.0 pe 1.98 4.42 2.39 1.150 2.201 1.575 50.3 112.3 60.7 29.21 55.91 40.0 ps 1.24 2.13 2.31 1.060 2.201 31.5 54.1 58.7 26.93 55.91 psc 1.24 2.13 2.51 1.060 2.520 31.5 54.1 63.8 26.92 64.01 psj 1.24 2.13 2.72 1.060 2.600 31.5 54.1 69.1 26.92 66.00 1.24 2.13 2.31 1.120 2.201 31.5 54.1 58.7 28.45 55.91 * panel cutout for thickness of .031 - .079 (0.8 - 2.0) . for panel thickness at .083 - .114 (2.1 - 2.9) use 2.213 (56.21). + panel cutout for thickness of 0.06 - 0.09 (0.76 - 2.29) . psl specifications ? filtered models maximum leakage current, each line-to-ground: @ 120 vac 60 hz: h, l models 2a s, z models 0.25ma @ 250 vac 50 hz: h, l models 5a s, z models .50ma hipot rating (one minute): line-to-ground 1500 vac line-to-line 1450 vdc operating voltages: selectable or fixed 115/230 vac fuseholder: accepts one or two fuses* 1/4? x 1-1/4? or 5 x 20 mm operating frequency: 50/60 hz rated voltage: 120/250 vac switch: double-insulated rated for 10,000 operations at full load. 51 amp inrush capability. terminals: 0.187? x 0.032? terminal tabs *conversion clip provided on fuseholder for single fuse models. case styles ? filtered models metric shown in italics. pe * for snap-in applications, the d sides of the cutout must have a .02 ( .508 ) radius on the installation side. note: snap-in models allow front mounting only. ps not recommended for plastic panels. back view for shielded models use d = 1.120 . + .008 ? .000 pe (high performance) ps high performance typical panel cutout +.008/- .000 +.20/-.00 +.008/- .000 +.20/-.00 mounting holes dia. (2) countersunk holes .125 3.18 + * * ? ? shields can be used only with filtered models. shields add approximately 0.06? to depth. b and c shields may not be used with extenders. ? ?


▲Up To Search▲   

 
Price & Availability of PSJS0S000

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X