thecopyrightandauthorityfortheinterpretationoftheproductsarereservedby mornsun tcxxxpw-ex 2013.11.01-a/0 page1of4 features isolation (input, output and power supply) 12.5mm slim case high accuracy (0.1% f.s.) high linearity (0.1% f.s.) low temperature drift(50ppm/ c) low-power dissipation excellent emc performance miniusb port communication input / output range programmable high reliability(mtbf>500,000 hours) generaldescription tcxxxpw-ex thermocouples isolation safety barrier seriesreceivedfromthehazardousareaofthermocouple signalsormvlevel,andconvertedtothestandardanalog currentorvoltagesignalwhichisisolatedwithapplicationfield, andtransmittedtothecontrolcabinet. whilelimitingthe energyofintrinsicallysafeendstringintohazardousarea,to ensurethatthesystemisintrinsicallysafeexplosion-proof performance.theproducthasaminiusbinterface,itcanbe usedforprogrammingtoconfigurethetypeandrangeofinput andoutputsignals.theproducthastheinternalcoldjunction compensation function. anindependentpower supplyis neededfortheproductlatorwithisolationpoweroutputyou need.andtheportofpowersupply,inputandoutputare isolatedfromeachother.thethicknessis12.5mm. connection of field devices and the regions: thermocouples; zone 0,zone 1,zone 2; iia,iib,iic,t4~t6 hazardousarea.productapplication:widelyusedinchemical, petroleum,pharmaceutical,metallurgy,coalmine,naturalgas, electricity,etcsafetyexplosionprotectionsystem. programmable thermocoupies isolationsafetybarrier tcxxxpw-exseries partnumbersystem tcxxxpw-ex slim case serial number channel configuration thermalcouplesignal transducer type programmable explosion protection certificate symbol selectionguide outputtype 1input1output 1input2output currentoutput tc100pw-ex tc600pw-ex voltagetype TC140PW-EX tc640pw-ex loopoutput tc102pw-ex tc602pw-ex inputsignal: inputsignal range theminimumrange r -40~+1700 600 s -40~+1700 600 k -150~+1370 120 j -80~+900 100 t -160~+390 100 b 320~+1820 780 e -80~+700 500 mv -60~+60mv 10mv outputsignal: outputtype outputsignal currentoutput 4~20ma/0~20ma(programmable) voltageoutput 0~5v/0~10v/1~5v/2~10v(programmable) note: 1.customersneedtochoosethetypeoftheinputsignal,outputsignalandrange.wecouldalsooffercustomerdesignforspecialinputandoutput. 2.youcangettheusbadaptert-01fortheisolatorfrommornsunfreeofchargeifyouneed. 3.factorydefault theinputsignaltypesarethemvsignal,theoutputsignalis4~20maandrangeis-60 +60mv.
thecopyrightandauthorityfortheinterpretationoftheproductsarereservedby mornsun tcxxxpw-ex 2013.11.01-a/0 page2of4 electricalcharacteristics powerinput parameters inputvoltage 18~30vdc typicalvalues 24vdc powerdissipation 1.8w powerprotection reversepolarityprotection safearea inputsignal seeselectionguide coldjunctioncompensation compensationrange:-25~+75 (errorislessthan1 cper20 ) methodofcompensation:internalcompensation hazardousarea faultoutput outputtype 4~20ma 0~20ma 1~5v 0~5v 0~10v 2~10v inputdisconnection 23ma 23ma 5.75v 5.75v 11.5v 11.5v lowerlimitalarm about3ma about21ma about0.75v about5.25v about10.5v about1.5v upperlimitalarm about22ma about22ma about5.5v about5.5v about11v about11v normaloperation a1,a2lightoff upperlimitalarm abovetheupperlimitofrange+5 (temperaturesignal)or+2mv(mvsignal),outputsignal isabout110%ofthemaximum,a1hasbeenbright. lowerlimitalarm belowthelowerlimitofrange-5 (temperaturesignal)or-2mv(mvsignal),outputsignalis about15%ofthemaximum,(outputtypesare4~20ma,2~10v,1~5v)or105%ofthemaximum (outputtypesare0~20ma,0~5v,0~10v) a2hasbeenbright. breakalarm brokenaccidentallyorinputsignal 70mv,outputsignalis115%ofthemaximum,a1anda2 brightatthesametime loadcapacity communicationport 500 (outputcurrentmaximum) 1m (outputvoltagemaximum) (ue-4)/0.02(looppowersupplyoutput) 20v ue 30v communicationinterface miniusbport communicationprotocol see"mornsunmodbusprotocolrules" transmissioncharacteristics zerooffset 0.1%f.s. sin=0,100%load,@25 accuracy 0.1%f.s. full-scalerange,100%load,@25 temperaturedrift 0.0050%f.s./ (-25 ~+71 operatingtemperaturerange) responsetime <0.5s isolationcharacteristics electricalisolation safeareaandhazardousarea2.5kvac1min,leakagecurrent 5ma outputandpowersupply2.5kvdc1min,leakagecurrent 5ma insulationresistance 100m ,500vdc signalinputport,signaloutputport) emccharacteristics emi ce cispr22/en55022classa re cispr22/en55022classa ems esd iec/en61000-4-2 contact 4kv/air 8kv perf.criteriab rs iec/en61000-4-3 10v/m perf.criteriaa eft iec/en61000-4-4 powerport 2kv perf.criteriab iec/en61000-4-4 signalport 1kv perf.criteriab surge iec/en61000-4-5 powerport 1kv/2kv perf.criteriab iec/en61000-4-5 signalport 1kv linetognd perf.criteriab cs iec/en61000-4-6 3vr.m.s perf.criteriaa standards&certificates explosionprotectioncertificatemarkcertificatemark [exiaga]iic explosionprotectioncertificateparameters um=250vrms,uo=10.5v,io=21ma,po=56mw,co=1.7uf,lo=10mh explosionprotectioncertificateagency chinanationalqualitysupervisionandtestcentreforexplosion protectedelectricalproducts explosionqualifiedno. cnex13.3054
thecopyrightandauthorityfortheinterpretationoftheproductsarereservedby mornsun tcxxxpw-ex 2013.11.01-a/0 page3of4 othercharacteristics temperature operatingtemperature:-25~+71 transportandstoragetemperature:-40~+85 package 35mmdin-railpackage:t-railcardpackage(din50022),pluggableconnectionpin,thickness12.5mm safetyclass ip20(iec60529/en60529) weight 1input1output:about100g;1input2output:about135g connection 1.connectionuseddismountableterminals; 2.crosssectionareaofwiring:0.5mm 2 ~2.5mm 2 ; 3.thelengthofbarewireisabout8mm,lockedupbythem3bolt. selectionguidelinesforintrinsicallysafetyexplosionprotectionsystem 1. theexplosionprotectiongradeofthebarriermustbenotlessthanthatofintrinsicallysafetyexplosionprotectiondeviceinspot. 2. takeinconsiderationofhazardousendoutputresistanceandloopresistancemakesurethebarrieroutputvoltagemeetstheminimum operationvoltagerequirementofintrinsicallysafetydeviceinspot. 3. thesafetyparametersaboutintrinsicallysafetyendmeets: uo ui,io iin,po pin co cin, lo lin 4. selectsuitablesafetybarrierwhichmatchestheintrinsicallysafetydeviceinspotaccordingtothepowerpolarity,signaltypeandtransmission modeaboutthedevice. 5. muchmoreprotectionisrequired,whichcanavoidtheinfluenceoftheleakagecurrentgeneratedbysafetybarrieronintrinsicallysafetydevice inspot. operationnotes 1.pleasereadtheusermanualcarefullybeforeusing.ifanyquestionpleasecontactourtechnicalsupportdepartment. 2.pleasedonotusethisproductinhazardousarea. 3.thepowersupplyofthisproductshouldbedcpowersource.itisforbiddentouse220vacpowersupply. 4.toavoidinvalidexplosionprotectionfunction,oranyfailure,usersdisassemblethisproductisforbidden. applicationcircuitdiagram& pindescription bottom power supply port 11 12 9 10 7 8 inside 1 2 3 4 5 6 outside p o w e r + p o w e r - p o w e r + p o w e r - inside outside inside outside inside outside inside outside inside outside note: when use bottom power supply, anyone group or both is ok. pin description(1input2output) 1 nc 2 nc 3 nc 4 nc 5 signal1input- 6 signal1output+ 7 signal1output- 8 signal2output+ 9 signal2output- 10 powerinput+ 11 powerinput- 12 signal1input+ tc100pw-ex TC140PW-EX tc102pw-ex 5 6 + - channel 1 8 7 + - channel 1 12 11 power safe area + - mv hazardous area rl 420ma vo rl current source output voltage source output + - + - rl 420ma + - ue + - loop supply power output output channel output channel
thecopyrightandauthorityfortheinterpretationoftheproductsarereservedby mornsun tcxxxpw-ex 2013.11.01-a/0 page4of4 note: 1.allspecificationsmeasuredatta=25 c,humidity<75%,nominalinputvoltageandratedoutputloadunlessotherwisespecified. 2.inthisdatasheet,allthetestsetupandmethodsarebasedonourcorporatestandards. 3.allcharacteristicsaremeantforlistedmodel,non-standardmodelsmayperformdifferently,youcancontactmornsunfaeformoredetails. 4.contactusforyourspecificrequirement. 5. specificationsaresubjecttochangewithoutpriornotice. mornsunscience&technologyco.,ltd. address:no.5,kehuist.1,kehuidevelopmentcenter,scienceave.,guangzhousciencecity,luogangdistrict,guangzhou,p.r.china. tel:86-20-38601850 fax:86-20-38601272 e-mail: info@mornsun.cn http://www.mornsun-power.com tc600pw-ex tc640pw-ex tc602pw-ex 12 11 power 8 7 + - channel 1 + - 5 6 10 9 + - channel 2 channel 1 safe area hazardous area mv + - rl 420ma rl 420ma vo1 rl vo2 rl rl 420ma ue rl 420ma ue current source output voltage source output loop supply poweroutput output channel 1 output channel 1 output channel 2 output channel 2 + - + - + - + - + - + - + - + - installation&disassembly installation din35mmstandardrailinstallation: 1. insertthetopoftheinstrumentcardintherail; 2. pushthebottomoftheinstrumentintotherail. 1 2 disassembly 1. insertascrewdriverbetweenthebottomofthecardlockandtherail; 2. pullupthescrewdriverandpressthecardlockdownwards; 3. pulltheinstrumentoutoftherail. 1 2 3 packagingdimension&packagingdiagram
|