  coinlight-ostar? - co06a data sheet www.osram.com/led-systems picture for datasheet is missing !!! benefits powered by ostar? - lighting ? 38 optics for wide flood ? available in white, 3 colour temperatures ? low energy consumption ? applications downlight ? shop lighting ? orientation and accent lighting ? color voltage [v dc]* power [w]* radiance angle []* wavelength [nm] color temp [k]* lum. intensity [cd]* current [a]* product number of leds technical operating data white 24 12,0 38 5400 k 450 0,5 co06a-w4-854 1 white 24 12,0 38 5400 k 310 0,5 co06a-w3-854 1 white 24 12,0 38 4700 k 450 0,5 co06a-w4-847 1 white 24 12,0 38 4700 k 310 0,5 co06a-w3-847 1 white 24 12,0 38 3000 k 330 0,5 co06a-w4-730 1 white 24 12,0 38 3000 k 240 0,5 CO06A-W3-730 1 all data are related to the entire module due to the special conditions of the manufacturing processes of led the typical data of technical parameters can only reflect s tatistical figures and do not necessarily correspond to the actual parameters of each single product which could differ from the typical data. preliminary data **) discontinued *) +) technical features powered by one high perfomance osram ostar? - lighting ? diameter of led module: ? 50 mm ? dimension of coinlight-ostar? similar to decostar? ? 38 viewing angle for wide flood ? operation only with optotronic? power supplies: ot20, ot20s, ot75, ot75e ? only parallel connection allowed ? parallel connection of up to 6 modules with the power feed in the center to one ot75 ? dimmable by pulse width modulation (pwm) ? cable length 500 mm, cable ? 1.6 mm/awg 22 ? cable length 500 mm, cable ? 0,2 mm2/awg 24 ? up to 20,000 h lifetime for tc<85c ? page 1 of 4 co06a - 08.02.2010
drawings drawin g is missin g !!! operating temperature at tc-point [ c ] * storage temperature [ c ] * product voltage range [ v dc ] * reverse voltage [ v dc ] * minimum and maximum ratings co06a-w4-854 23 25 25 ... -30 105 -30 105 ... ... co06a-w3-854 23 25 25 ... -30 105 -30 105 ... ... co06a-w4-847 23 25 25 ... -30 105 -30 105 ... ... co06a-w3-847 23 25 25 ... -30 105 -30 105 ... ... co06a-w4-730 23 25 25 ... -30 105 -30 105 ... ... CO06A-W3-730 23 25 25 ... -30 105 -30 105 ... ... exceeding maximum ratings for operating and storage temperature will reduce expected life time or destroy the led module. exceeding maximum ratings for operating voltage will cause hazardous overload and will likely destroy the led module. the temperature of the led module must be measured at the tc-point according to en60598-1 in a thermally constant status with a temperature sensor or a temperature sensitive label. for exact location of the tc-point see drawing below. *) page 2 of 4 co06a - 08.02.2010
safety information the led module itself and all its components must not be mechanically stressed. ? assembly must not damage or destroy conducting paths on the circuit board. ? ? to avoid mechanical damage to the connecting cables, the module should be attached securely to the intended substrate. heavy vibration should be avoided. parallel connection is highly recommended as safe electrical operation mode. serial connection is not recommended. unbalanced voltage drop can cause hazar dous overload and damage the led module. observe correct polarity! depending on the product incorrect polarity will lead to emission of red or no light. the module can be destroyed! correct pola rity immediatelly! (see "reverse voltage", page 2) ? ? ? pay attention to standard esd prec autions when installing the module. ? please ensure that the power supply is of adequate power to operate the total load. ? in case of thermal overload in the applic ation coinlight-ostar? intelligent protection system would switch over into reversible blinking mode. the led module will not be damaged. improving heat dissipation by extending the size of the heat sink or reducin g the ambient temperature would provide regular operation mode. ? electrical contact is achieved with the contact cables. one coinlight-ostar? can be operated on one ot20 or ot20s. a maximum of 6 modules can be installed parallel on one optotronic 75w. coinlight-ostar? cannot be operated with ot dali 25/220-240/24 rgb as the intelligent protection system of the module is not supported. ? coinlight-ostar? works as a three wire system: red cable (plu spole), black cable (minuspole) and a white cable for dimming. ? a schematic drawing with wiring diagrams for dimming purpose is shown in the separate application note: "dimming coinlight- ostar?". ? the module, as manufactured, has no conformal coating and therefore offers no inherent protection against corrosion. ? damage by corrosion will not be honored as a materials defect clai m. it is the user's responsibility to provide suitable protec tion against corrosive agents such as moisture and condensation and other harmful elements. ? if the ip rating of the fixture should be higher than ip20, the design of the housing should be according to the ip standards i n the application. to also ease the luminaire/installation approv al, electronic control gear for led or le d modules should carry the ce mark and b e enec certified. in europe the declarations of conformity must include the following standards: ce: ec 61347-2-13, en 55015, iec 61547 and iec 61000-3-2 - enec: 61347-2-13 and iec/en 62384. also check for the mark of an independent authorized certification institute. please see the relevant brochure for more detailed information (see "related and further information") installation of led modules (with power supplies) needs to be made with regard to all applicable electrical and safety standard s. only qualified personnel should be allowed to perform installations. ? in order to drive osram led-modules safely, it is absolu tely necessary to operate them with an electronically stabilised power supply protecting against s hort circuits, overload and overheating. osram optotronic? electronic control gear complies to al l relevant standards and guarantees safe operation. page 3 of 4 co06a - 08.02.2010
assembly information ? the mounting of the module has to be done on a metal heat sink! ? in order to optimise the thermal management the metal surface needs to be clean (free from dirt and oil) and planar for the bes t contact with the led module. ? the housing of the coinlight-ostar? is a primary heat sink. the metal surface increases the cooling effect, prolongs the servic e life time and increase luminous intensity. ? heat sink cohs-50 as accessory part ava ilable for optimized cooling of the module. productgroup productname ean * s-unit * ordering guide coinlight-ostar? co06a-w4-854 4008321231697 20 coinlight-ostar? co06a-w3-854 4008321231451 20 coinlight-ostar? co06a-w4-847 4008321231758 20 coinlight-ostar? co06a-w3-847 4008321231512 20 coinlight-ostar? co06a-w4-730 4008321231819 20 coinlight-ostar? CO06A-W3-730 4008321231574 20 ean: ordering number per single module s-unit: modules per shipping unit *) note: typical performance data are subject to change without any further notice, particularly as led technology evolves. related and further information optotronic? data sheets ? http://catalog.myosram.com the new dimension of light ? 153 s006 gb www.osram.com/led-systems-downloads optotronic? technical guide ? 130 t008 gb www.osram.com/ecg-downloads application note: dimming coinlight-ostar? ? new standards for led control gear ? 130 w011 gb www.osram.com/ecg-download data sheet heat sink cohs-50 ? www.osram.com/led-systems-downloads sales and technical support sales and technical support is given by the local osram subsidiaries. on our world wide homepage all osram subsidiaries are listed with complete address and phone numbers. osram gmbh hellabrunner strasse 1 d - 81536 mnchen germany www.osram.com +49 (0)89 6213-0 page 4 of 4 co06a - 08.02.2010
application note dimming coinlight-ostar ? 0. products coinlight-ostar? ot rgb dim without illustration oti dali dim c ot dim ot dmx rgb dim ot dmx 3x1 rgb dim b ot 60 easy a ot 75e/24 a ot 75/24 a ot 20s/24 a ot 20/24 configuration osram optotronic power supply ot rgb dim without illustration oti dali dim c ot dim ot dmx rgb dim ot dmx 3x1 rgb dim b ot 60 easy a ot 75e/24 a ot 75/24 a ot 20s/24 a ot 20/24 configuration osram optotronic power supply combination chart coinlight-ostar? is a high end led module, that can be easily used in various combinations with osram powe r supplies and control systems. dimming coinlight-ostar? benefits: - wide dimming range from 0 C 100% - linear dimming characteristic - no noise generation 1. operation with power supply (no dimming)
page 2 of 2 application note C dimming coinlight-ostar 2. operation with ot easy 60 (dimmable) use of coinlight-ostar? in basic light management s ystems with ot easy 60 which consists power supply and control in one device. 3. operation with ot dim (dimmable) operation of coinlight-ostar? with a power supply i n combination with 1-channel dimming device.


▲Up To Search▲   

 
Price & Availability of CO06A-W3-730

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X