vicor corp. tel: 800-735-6200, 978-470-2900 fax: 978-475-6715 vi-200 dc-dc converters 50 to 200 watts rev. 2.4 page 1 of 5 set your site on vicor at www.vicorpower.com input voltage operating storage e = ? 10 to + 85 e = ? 20 to +100 c = ? 25 to + 85 c = ? 40 to +100 i = ? 40 to + 85 i = ? 55 to +100 m = ? 55 to + 85 m = ? 65 to +100 overtemperature shutdown 95c typical (recycle power to restart) features ? rohs compliant (ve-200) ? up to 50 w/in 3 ? culus, ctvus ? up to 90% efficiency ? size: 4.6" x 2.4" x 0.5" (116,8 x 61,0 x 12,7mm) ? remote sense and current limit ? ovp, thermal shutdown ? logic disable ? wide range output adjust ? compatible power booster modules ? zcs power architecture ? low noise fm control ? ce marked product highlights the vi-200 family, with over 12 million units shipped, is vicors broad series of zero-current-switching component-level dc-dc converters. operating at frequencies up to 2 mhz, vi-200 family converters offer exceptional power density, efficiency, noise performance, reliability and ease of use. booster modules (vi-bxx) provide a simple, cost-effective, off-the-shelf solution for higher power output requirements. one or more boosters may be used to create synchronous arrays capable of supplying several kilowatts of output power. the flexibility of vicors power components is also available in half-size, half-power vi-j00 minimods. packaging options slimmods?, high power density, flangeless devices and finmods?, featuring integral finned heatsinks. slimmod: option suffix: - s example: vi - 2xx - xx - s finmod: option suffix: - f1, - f2, -f3 or -f4 examples: vi - 2xx - xx - f1 , 0.25" fins, longitudinal vi - 2xx - xx - f2 , 0.50" fins, longitudinal vi - 2xx - xx - f3 , 0.25" fins, transverse vi - 2xx - xx - f4 , 0.50" fins, transverse busmod: option suffix: -b1 megamod: vi - lxx - xx 5 v < 5 v y = 50 w y = 10 a x = 75 w x = 15 a w = 100 w w = 20 a v = 150 w v = 30 a u = 200 w u = 40 a for additional output power use ?boosters?. change (vi- 2 xx-xx) to (vi- b xx-xx) z =2.0 v y =3.3 v 0 =5.0 v x =5.2 v w =5.5 v v =5.8 v t =6.5 v r =7.5 v m = 10 v 1 = 12 v p = 13.8 v 2 = 15 v n = 18.5 v 3 = 24 v l = 28 v j = 36 v k = 40 v 4 = 48 v h = 52 v f = 72 v d = 85 v b = 95 v v i -2 [a] converter selection chart [a] e for rohs compliant product grade temperatures ( c) output power/current vout output voltage data sheet vi-200, ve-200 dc-dc converters 50 to 200 watts [c] transient voltage for 1 second. [d] x,v, and t outputs are 50 w max. nominal input range max power [ b ] low line transient [c] full power 75% max power 0 = 12 v 10 ? 20 v (1) n/a 22 v v = 24 v 10 ? 36 v (7) n/a n/a 1 = 24 v 21 ? 32 v (4) 18 36 v w = 24 v 18 ? 36 v (2) n/a n/a 2 = 36 v 21 ? 56 v (3) 18 60 v 3 = 48 v 42 ? 60 v (4) 36 72 v n = 48 v 36 ? 76 v (4) n/a n/a 4 = 72 v 55 ? 100 v (4) 45 110 v t = 110 v 66 ? 160 v (2) n/a n/a 5 = 150 v 100 ? 200 v (5) 85 215 v 6 = 300 v 200 ? 400 v (4) 170 425 v 7 = 150/300 v 100 ? 375 v (6) 90 n/a [ b ] maximum 5 v > 5 v < 5 v power outputs outputs outputs (1) 75 w 75 w 15 a (2) 150 w 150 w 30 a (3) 100 w 100 w 20 a (4) 200 w 200 w 40 a (5) 150 w 200 w 40 a (6) 75 w 100 w 20 a (7) 50 w 75 w [d] 15 a
vicor corp. tel: 800-735-6200, 978-470-2900 fax: 978-475-6715 vi-200 dc-dc converters 50 to 200 watts rev. 2.4 page 2 of 5 set your site on vicor at www.vicorpower.com vi-200 e-grade vi-200 c-, i-, m-grade parameter min typ max min typ max units test conditions inrush charge 120 x 10 -6 120 x 10 -6 200 x 10 -6 coulom b s nominal line input reflected 10% 10% i in nominal line, full load ripple current ? pp input ripple rejection db 120 hz, nominal line db 2400 hz, nominal line no load power dissipation 1.35 2 1.35 2 watts vi-200 e-grade vi-200 c-, i-, m-grade parameter min typ max min typ max units test conditions gate out impedance 50 50 ohms gate in impedance 1000 1000 ohms gate in open circuit voltage 6 6 volts use open collector gate in low threshold 0.65 0.65 volts gate in low current 6 6 ma power sharing accuracy 0.95 1.05 0.95 1.05 vi-200 e-grade vi-200 c-, i-, m-grade parameter min typ max min typ max units test conditions setpoint accuracy 1% 2% 0.5% 1% v nom load/line regulation 0.5% 0.05% 0.2% v nom ll to hl, 10% to full load load/line regulation 1% 0.2% 0.5% v nom ll to hl, no load to 10% output temperature drift 0.02 0.01 0.02 % / c over rated temp. long term drift 0.02 0.02 %/1k hours output ripple ? pp: 2 v, 3.3 v 150 60 100 mv 20 mhz b andwidth 5 v 5% 2% 3% v nom 20 mhz b andwidth 10 ? 48 v 3% 0.75% 1.5% v nom 20 mhz b andwidth trim range [a] 50% 110% 50% 110% v nom total remote 0.5 0.5 volts 0.25 v max. neg. leg sense compensation ovp set point 125% [ b ] 115% 125% [ b ] 135% v nom recycle power current limit 105% 135% 105% 125% i nom automatic restart short circuit current [c] 20% 140% 20% 130% i nom converter specifications (typical at t bp = 25c, nominal line and 75% load, unless otherwise specified) 25 + 20 log ( vin ) vout 30 + 20 log ( vin ) vout 20 + 20 log ( vin ) vout [a] 10 v, 12 v, 15 v outputs, and v input range (10 ? 36 v) standard trim range 10%. consult factory for wider trim range. 3.3 v output trim range 2.20 to 3.63 v, 95 v output ?50 + 0% trim range. [ b ] 131% nominal for b ooster modules. [c] output voltages of 3.3 v or 5 v incorporate fold b ack current limiting; all other outputs provide constant current limiting. input specifications output characteristics control pin specifications
vicor corp. tel: 800-735-6200, 978-470-2900 fax: 978-475-6715 vi-200 dc-dc converters 50 to 200 watts rev. 2.4 page 3 of 5 set your site on vicor at www.vicorpower.com vi-200 e-grade vi-200 c-, i-, m-grade parameter min typ max min typ max units test conditions efficiency 78 ? 88% 80 ? 90% baseplate to sink 0.07 0.07 c/watt with vicor p/n 20266 thermal impedance thermal shutdown [d] 90 95 105 90 95 105 c cool and recycle power (drivers only) to restart converter specifications (cont.) vi-200 e-grade vi-200 c-, i-, m-grade parameter min typ max min typ max units test conditions input to output 3,000 3,000 v rms baseplate earthed output to b aseplate 500 500 v rms input to b aseplate 1,500 1,500 v rms vi-200 e-, c-grade vi-200 i-, m-grade parameter min typ max min typ max units test conditions weight 6.2 6.3 6.4 7.2 7.3 7.4 ounces (176) (178) (181) (205) (208) (210) (grams) dielectric withstand characteristics thermal characteristics mechanical specifications [d] no overtemp protection in b ooster modules.
vicor corp. tel: 800-735-6200, 978-470-2900 fax: 978-475-6715 vi-200 dc-dc converters 50 to 200 watts rev. 2.4 page 4 of 5 set your site on vicor at www.vicorpower.com +.030 (0,76) -.000 (0) product id this surface full r 5 6 7 8 9 4 3 2 1 pin # 1 2 3 4 5 6* 7* 8* 9 function +in gate in gate out -in +out +sense trim -sense -out * do not connect on b ooster modules aluminum base .01 .040 (1,0) dia (7) places solder plate over copper alloy 0.080 (2,0) dia (2) places solder plate over copper alloy .30 .015 (7,6) (0,38) 1.80 (45,7) (106,7) (12,7) (5,6) min (3,0) (116,8) (61,0) (44,5) (7,6) min .15 (3,8) 2.10 (53,3) .40 (10,2) .35 .015 (8,9) (0,38) 1.40 (35,6) 1.00 (25,4) .70 (17,8) (91,4) .50 (12,7) vi-200 4.60 3.60 .15 (3,8) 4.20 .12 .22 .50 .30 2.40 1.75 standard 0.080 (2,0) dia (2) places matte tin over copper alloy rohs standard .040 (1,0) dia (7) places matte tin over copper alloy rohs mechanical drawing
vicor corp. tel: 800-735-6200, 978-470-2900 fax: 978-475-6715 vi-200 dc-dc converters 50 to 200 watts rev. 2.4 7/08 set your site on vicor at www.vicorpower.com vicor corporation 25 frontage road andover, ma, usa 01810 tel: 800-735-6200 fax: 978-475-6715 email customer service: custserv@vicorpower.com technical support: apps@vicorpower.com vicors comprehensive line of power solutions includes high density ac-dc and dc-dc modules and accessory components, fully configurable ac-dc and dc-dc power supplies, and complete custom power systems. information furnished by vicor is believed to be accurate and reliable. however, no responsibility is assumed by vicor for its use. vicor components are not designed to be used in applications, such as life support systems, wherein a failure or malfunc- tion could result in injury or death. all sales are subject to vicors terms and conditions of sale, which are available upon request. specifications are subject to change without notice. intellectual property notice vicor and its subsidiaries own intellectual property (including issued u.s. and foreign patents and pending patent applications) relating to the products described in this data sheet. interested parties should contact vicor's intellectual property department. warranty vicor products are guaranteed for two years from date of shipment against defects in material or workmanship when in normal use and service. this warranty does not extend to products subjected to misuse, accident, or improper application or maintenanc e. vicor shall not be liable for collateral or consequential damage. this warranty is extended to the original purchaser only. except for the foregoing express warranty, vicor makes no warranty, express or implied, including, but not limited to, the warranty of merchantability or fitness for a particular purpose. vicor will repair or replace defective products in accordance with its own best judgement. for service under this warranty, the buyer must contact vicor to obtain a return material authorization (rma) number and shipping instructions. products returned without prior authorization will be returned to the buyer. the buyer will pay all charges incurred in returning the product to the factory. vicor will pay all reshipment charges if the product was defective within the terms of this warranty. information published by vicor has been carefully checked and is believed to be accurate; however, no responsibility is assumed for inaccuracies. vicor reserves the right to make changes to any products without further notice to improve reliability, funct ion, or design. vicor does not assume any liability arising out of the application or use of any product or circuit; neither does it con- vey any license under its patent rights nor the rights of others. vicor general policy does not recommend the use of its compo- nents in life support applications wherein a failure or malfunction may directly threaten life or injury. per vicor terms and conditions of sale, the user of vicor components in life support applications assumes all risks of such use and indemnifies vic or against all damages.
|