  Datasheet File OCR Text:
  csm_cs1w-spu01-v2/02-v2_ds_e_3_1 1 sysmac cs-series high-speed data storage unit (sysmac spu) cs1w-spu01-v2/02-v2 high-speed collection of system data the cpu unit can collect large amounts of process data, operation data, inspection dat a, and other controlled system data quickly and automatically save the data in external storage media as csv files. features ? there is no need to write ladder programming to collect data. ev en with an existing system, just mount a sysmac spu unit and ad d it to the i/o tables to start data collection. ? use specified times or events as trigger s to record the contents of specified words in i/o memory in the cpu unit. ? in data storage mode, up to 65 data collection patterns are poss ible with one basic collection pattern and data collection patt erns 1 to 64. combine the collection patterns with events to simu ltaneously collect many different types of data. ? collected data can be stored in pc cards or in a computer c onnected via ethernet. data management middleware can be used to mak e a few simple settings to store the data in a host computer. ? recipes can be used to batch-write numeric or text string data, such as production parameters, in the memory areas of the cpu u nit. recipe data can be saved in a memory card in the sysmac spu unit to easily enable process switchovers. ? sysmac spu units with a unit version of 2. 1 or later also provide an ftp client. th is enables sending files of collected data t o an ftp server on a host computer, eliminating the need to write programming to store data in the host computer. system configuration cs1w-spu02-v2 lan straight ca b le (commercially a v aila b le) h ub or other net w ork de v ice sysmac spu unit cpu unit lan straight ca b le (commercially a v aila b le) spu-console setting/monitoring soft w are
2 cs1w-spu01-v2/02-v2 ordering information international standards ? the standards are abbreviated as follows: u: ul, u1: ul (class i division 2 products for hazardous locations), c: csa, uc: culu s, uc1: culus (class i division 2 products for hazardous locations), cu: cul, n : n k, l: lloyd, and ce: ec directives. ? contact your omro n representative for further details and ap plicable conditions for these standards. sysmac spu (high-speed data storage unit) support software option industrial switching hubs unit type product name specifications no. of unit numbers allocated current consumption (a) model standards pc card slot ethernet (lan) port 5v 26v cs1 cpu bus unit sysmac spu (high-speed data storage unit) 1 pc card type ii slot insert an omro n hmc-ef @@@ to use the memory card. 1 port (10/100base-tx) 1 0.56 ? cs1w-spu01-v2 uc1, ce 2 ports (10/100base-tx) 0.70 ? cs1w-spu02-v2 product name specifications model standards spu-console support software functions: unit settings, sampling settings, etc., for high-speed data collection units (required for making settings for this unit) os : windows 2000, xp, or vista WS02-SPTC1-V2 ? product name specifications model standards sysmac spu data management middleware function: data files collected by sysmac spu data man- agement middleware are automatically acquired at the personal computer, and can be registered in a database. os :windows 2000, xp, or vista 1 license ws02-edmc1-v2 ? 5 licenses ws02-edmc1-v2l05 memory cards flash memory, 128mb n ote: memory card is required for data collection. hmc-ef183 n , l, ce flash memory, 256mb hmc-ef283 flash memory, 512mb hmc-ef583 memory card adapter (for a computer's pcmcia slot) hmc-ap001 ce product name appearance specifications current consumption (a) model standards functions no. of pors failure detec- tion industrial switching hubs quality of service (qos): ether n et/ip control data priority failure detection: broadcast storm and lsi error detection 10/100base-tx, auto- n egotiation 3 n o0.22 w4s1-03b uc, ce 5 n o0.22 w4s1-05b 5 yes 0.22 w4s1-05c ce
cs1w-spu01-v2/02-v2 3 accessories mountable racks * the number of units that can be mount ed depends on the power supply capacity. c200hw-pa204 @ : 4 units max. c200hw-pa209r: 10 units max. model accessories specifications cs1w-spu01-v2 cs1w-spu02-v2 pf-in connector (premounted) connector for uninterruptible power supply pf-in connection: mc1.5/2-stf- 3.81, manufactured by phoenix contact model cs1 system cs1d system cpu rack expansion backplane (including longdistance expansion rack) sysbus remote i/o slave rack c200hx/ hg/he expansion i/o rack cpu rack expansion backplane cs1w-bc cs1w-bi cs1d-bc cs1d-bi @@ 3 @@ 2 @@ 3 @@ 2 052 042d 082s 092 082d cs1w-spu01-v2 cs1w-spu02-v2 16 units (per cpu unit) ? not supported not supported 16 units (per cpu unit) ?
4 cs1w-spu01-v2/02-v2 functional and performance specifications * memory card: hmc-ef @@@ memory card from omron or commercially available compact flash card. normal operation may not be possible with commercially available compact flash cards depending on the manufacturer and model of the card. general specifications: specifications conform to the general specifications of the sysmac cs-series cpu units. item specifications unit model number cs1w-spu01/02-v2 applicable cpu units cs series unit classification cpu bus unit unit number 0 to f mounting location cpu backplane or cs-series expansion backplane (cannot be mounted to c200h expansion i/o rack or sysmac bus remote i/o slave rack.) no. of units per plc 16 unit max. interfaces pc card slot pc card type ii, 1 slot (conforms to pc card standard release 8.0.) used by mounting memory card and hmc-ap001 memory card adapter. ? comm port for future expansion ethernet (lan) ports cs1w-spu01-v2: one port (10/100base-tx, rj45 modular connector) cs1w-spu02-v2: two ports (10/100base-tx, rj45 modular connectors) ups power failure input 24 vdc (+10%/-15%) input connect the power failure signal output line from the ups. settings and operation unit number switch (unit) rotary switch: sets the unit number of the unit as a cpu bus unit. select switch (select) toggle switch: sets the number of the command to execute. enter button (enter) pushbutton switch: confirms and starts execution of the command number set using the select switch. dip switch (dipsw) dip switch: system settings card button pressed to release the memory card inserted in the pc card slot. the memory card can then be removed. indications led indicators run, erc, erh, comm, lan1, lan2, card, and pf-in 7-segment display  displays error information and operating status of the sysmac spu unit.  displays the command number set on the select switch.  displays the ip address.  display other information. functions  sampling  saving files  network communications  recipe function operating modes data storage mode and sampling mode (either mode can be selected with the change operating mode command.) current consumption cs1w-spu01-v2: 5 vdc, 560 ma max. (sysmac spu unit only) other: memory card (hmc-ef @@@ ): 120 ma max. (supplied from power supply unit.) cs1w-spu02-v2: 5 vdc, 700 ma max. (sysmac spu unit only) other: memory card (hmc-ef @@@ ): 120 ma max. (supplied from power supply unit.) dimensions cs1w-spu01/spu02-v2: 35 130 101 mm (w h d) weight cs1w-spu01-v2: 280 g max. (including enclosed connector) cs1w-spu02-v2: 290 g max. (including enclosed connector)
cs1w-spu01-v2/02-v2 5 detailed specifications item specifications sampling sampling mode sampling patterns realtime sampling: 1 pattern normal sampling : up to 3 patterns starting methods any one of the following methods can be used: ? start automatically when sysmac spu unit is started. ? start with an spu-console operation. ? start with the sysmac spu unit?s front-panel command buttons. (specify the command number.) ? start from the cpu unit?s ladder program. interval user-specified intervals: ? 1 realtime sampling: 5 ms min. normal sampling : 100 ms min. data storage mode (unit ver. 1.2 or later) data collection patterns basic collection pattern : 1 pattern (required) data collection patterns : up to 64 patterns starting methods basic collection pattern (required) any one of the following methods can be used: ? start when a specified event occurs. (use a memory event or scheduled event. for details, see the description of data collection patterns 1 to 64 below.) ? start automatically when s ysmac spu unit is started. ? start with an spu-console operation. ? start with the sysmac spu unit?s front-panel command buttons. (specify the command number.) ? start from the cpu unit?s ladder program. data collection patterns 1 to 64 either of the following methods can be used to start when an event occurs: ? memory events: start when a cpu unit bit or word value matches a spec- ified condition. up to 500 memory events can be specified. ? scheduled events: start at a specified time or time interval. up to 16 sched- uled events can be specified. interval user-specified intervals: ? 2 ? 3 basic collection pattern: 5 ms min. data collection patterns: 100 ms min. data storage mode (unit ver. 2.0 or later) copy option basic collection pattern: cannot be set. data collection patterns: up to 10 patterns. shared sampling mode and data storage mode settings applicable cpu unit i/o memory areas cio area, wr area, hr area, ar area, dm area, and em area banks 0 to c specifying i/o memory areas specify the desired cpu unit i/o memory area (data area) with a variable. the data type can be specified with the variable. the variables can be managed in groups. variable data types bool, int, uint, dint, udin t, real, lreal, string, channel, uint bcd, udi nt bcd, word, dword, channel block record condition setting set whether or not to use a record condition. if a record condition is used, sampling data is stored within the sysmac spu unit only when the record condition is met. for example, sampling data can be recorded only while a specified bit is on or a specified word contains a particular value (comparison). data exchange with the cpu unit cpu bus unit area ? cpu unit to sysmac spu unit: command execution (such as starting/stop- ping sampling, clearing a sampling file, or saving a sampling file). ? sysmac spu unit to cpu unit: sys mac spu unit status information saving files collected data file format csv files indices (record number), time stamps (hh:mm:ss:ms), ns, sampling indices (serial numbers starting at 0 when sam- pling is started), data for each symbol delimited with com- ma, records delimited with carriage returns record contents number of sampling result records stored in one file any one of the following methods can be used. ? the number of records can be specified. ? a time period can be specified. (the nu mber of records is calculated automat- ically from the time period and interval between samples.) ? with a version 1.2 or later sysmac spu unit, the number of records can be left unspecified. (in this case, data is added to the file until data collection is stopped. records are added to one file from the start of data collection until the end.) scaling instead of directly storing the values collected from the cpu unit?s i/o memory, the collected values can be scaled with a linear equation or upper/lower limit range before storage (unit version 1.2 or later). file size 2 gb per file record size specified by user. number of records specified by user or calculated automatically. saving method data can be saved to a single file or multiple files (up to 1,200 files). network communications windows network shared folders files in the memory card inserted in th e pc card slot in the sysmac spu unit can be shared with a windows 2000/xp/vista personal computer. ftp ftp server/client provided.
cs1w-spu01-v2/02-v2 6 s network communications fins communications ? fins server to execute fins command ? routing to transfer fins messages recipe function data storage mode (unit ver. 2.0 or later) number of fields 10,000 recipe files file format: csv the file size is restricted by the size of file that can be stored in the recipe folder. records : specified by the user. number of records no limit, but restricted by the file size that can be stored in the recipe folder. writing method conversion method: each field is written to the specified address in the specified data type. continuous region method: data written to continuos memory addresses. searching for recipe keys searching within files: the text string th at was passed as the key is searched for in the target search columns in the recipe files and the rows for any matches that are found are extracted as recipe data. searching for file names: the text string that was passed as the key is searched for in the recipe file names (i.e., a se arch is made for key.csv), and the files with matching files names are used as recipe files just like previous versions. key list search: a search is made for recipe keys with the method used for unit version 2.0. * 1. in both cases, the sampling cannot be performed faster than the cpu unit?s cycle time. the actual sampling interval will always be longer than the cpu unit?s cycle time even if the sampling interval is set shorter than the cycle time. * 2. the data collection patterns use the data collected by the basic collection pattern, so the data will be collected at the basic collection pattern?s interval even if the data collection pattern?s interv al is set shorter than the basi c collection pattern?s interval. * 3. the actual basic collection pattern interval will always be longer than the cpu unit?s cycle time even if the sampling interval is set shorter than the cycle time. item specifications
cs1w-spu01-v2/02-v2 7 spu-console (setting/monitor ing software) specifications the spu-console is a software product used for omron's storage and processing unit (c alled the sysmac spu unit) to set and oper ate the sysmac spu unit, monitor operating status/errors, display trend graphs, and perform other operations from a personal computer. spu-console specifications software package contents the WS02-SPTC1-V2 contains the following software and data. ? spu-console execution program the program that performs sysmac spu unit settings and operations. ? microsoft .net framework version 1.1 redistribution package microsoft .net framework version 1.1 is r equired to run the spu-console. the microso ft .net framework version 1.1 redistributio n package provided in the package can be used to install microsoft .net framework in the computer. ? sysmac spu unit system data this system data is transferred to the sysmac spu unit. ? finsgateway version 2003 this communications middleware is required to run the spu-console. ? manual data the manual data includes the sysmac spu unit operation manual (cat. no. v236), the sysmac spu-console operation manual (cat. no . v230), the sysmac spu-console version 1.3 operation manual (ca t. no. v231), and the sysmac spu-console version 2.1 operation manual (cat. no. v237) in pdf (portable document format). item specifications model number WS02-SPTC1-V2 (spu-console ver. 2.1) system requirements computer hardware computer that meets the system requirements for microsoft windows xp professional cd-rom drive required for installation. display super vga (800 600) or better high-resolution video adapter and monitor mouse must conform to the models supported by the applicable os. network card a separate ethernet network card is required for computers that do not have a lan port. os microsoft windows 2000 professional microsoft windows xp home edition microsoft windows xp professional microsoft windows vista application platform microsoft.net framework version 1.1 microsoft.net framework version 2.0 communications platform finsgateway version 2003 functions unit information, unit setup, variable settings, collection pattern settings, event settings, recipe set- tings, trend graphs, and reports unit information monitor sysmac spu unit operating status and error information are displayed. operation operations, such as starting sampling unit setup ip network settings fins network settings variable settings setting items to sample (by specifying i/o memory addresses using variables) collection pattern settings collection pattern settings (period, file designations for saving, etc.) recipe settings (data storage mode) recipe settings (recipe file, wr ite destination, key, etc.) event settings (in data storage mode) memory event settings settings for conditions according to chan ges in memory (e.g., bits turning on) scheduler settings settings for schedules (e.g., specific times, time intervals) trend graphs historical trends csv files are read and displayed. realtime trends (sampling mode) current sampling data is read and displayed in trend graphics in real time.
8 cs1w-spu01-v2/02-v2 sysmac spu data management middleware (edms) the sysmac spu data management middleware (hereafter the edms) is software that reads csv-format files from an spu unit and cop ies the files to a specified folder on a computer hard disk over an ethernet network. with version 2.0 or higher, the coll ected data can be stored in a database. edms structure the edms consists of the following programs. ? copy task service the copy task service copies files from an spu unit and saves them to a computer hard disk on the same network. the service ope rates in the background and is used to monitor spu units. ? database storage service the database storage service stores the file s that are copied to the computer into a database. the service operates in the back ground. ? edms-console the edms-console is a user-interfa ce program that provides access to the setti ng windows. it accesses the copy setting window, for example, to allow the user to input copy task service settings, specify operations, and moni tor operating conditions. the program displa ys the files that have been copied to the computer in a li st that can be used for data management. the database storage windows enable setting the database storage serv ice, controlling the storage operation, and monitoring ope rating status. edms specifications item description model ws02-edmc1-v2 system requirements processor intel pentium, celeron, or compatible processor cd-rom drive required for installation display super vga (800 600) or better high-resolution video adaptor and monitor mouse mouse supported by the applicable os. network card computers without a lan port require an ethernet network card (sold separately). comp u ter collected data spu unit cpu unit data b ase storage f u nction the collected data can b e stored in a data b ase either at the press of a bu tton or in the b ackgro u nd after starting the comp u ter. copy f u nction the collected data can b e copied to the comp u ter either at the press of a bu tton or in the b ackgro u nd after starting the comp u ter. sysmac spu data management middle w are (edms) db ethernet cs v files sampling copy setting w indo w copy task ser v ice edms finsgate w ay ser v ice edms-console data b ase storage setting w indo w data b ase storage ser v ice microsoft n et frame w ork1.1 microsoft w indo w s 2000 / xp / v ista
cs1w-spu01-v2/02-v2 9 software package contents the ws02-edmc1-v2 software package contains the following items. ? edms installation program the edms installation program is used to install the copy task service and edms-console on a computer. ? microsoft .net framework version 1.1 redistributable package microsoft .net framework version 1.1 is required to run the spu -console. the redistributable pa ckage provided in the software p ackage can be used to install .net framework on the computer. ? finsgateway version 2003 the finsgateway version 2003 communications midd leware is required to run the spu-console. ? operation manual the sysmac spu data management middleware user?s manual (cat. no. v232) is included in pdf format in the software package. system requirements os microsoft windows 2000 professional microsoft windows xp home edition microsoft windows xp professional microsoft windows 2003 server microsoft windows vista application platform (execution environment) microsoft .net framework version 1.1 microsoft data access component 2.6 or later communications platform finsgateway version 2003 other software requirements spu-console (sold separately) required to input spu unit settings. registration of applicable spu units spu units can be registered by specifying the ip address and name of the unit (same for the spu-console). copy function copies files from the memory card in a registered spu unit to a specified folder on a computer hard disk. the function is enabled only when two or more is set in the number of files field from the spu- console. settable number of copies 256 max. copy start conditions start button or automatically on computer startup. copy timing files will be saved to the computer hard disk over the network automatically when copying is enabled (data collection has stopped or files have been transferred). storage location any specified folder saved file name file names can be created automatically using one or any combination of the following objects: any text string, the name of the copy, the name of the source spu unit, the time or date (month, day, year) the file was copied, consecutive file numbers, the date or time of the start record, and the date or time of the last record. copy monitoring cycle settable cycle for monitoring when copying is enabled. default: 10 s status indicators used to check starting, started (monitoring copying), copying, stopped, and error status conditions. log display press the display of log button to display the operating status or an error log list that shows the month/day/year, time, event id, and description. database storage function data files that are copied to a specified folder on a computer hard disk are stored in a database. the function is enabled only when three or more is set in the number of files field from the spu-console. settable number of data base storage services 65 max. database storage start conditions start button or automatically on computer startup. storage timing files will be automatically stored in the database as soon as storable files are detected. applicable databases microsoft access 2000, 2002, 2003 microsoft sql server 2000, 2005 oracle database 10g2 copy folder mo nitoring cycle settable cycle for monitoring when there are storable files. default: 10 s status indicators used to check whether storage is in progress (monitor- ing for storable files) or stopped. log display press the display of log button to display the operating status or an error log list that shows the month/day/year, time, and description. spu clock synchronization function the spu unit (version 1.2 or later only) and cpu unit clocks are periodically synchronized with the computer clock. item description
10 cs1w-spu01-v2/02-v2 functions supported by sysmac spu units according to unit versions cs1w-spu01/02-v2 spu-console compatibility with un it versions of sysmac spu units cs1w-spu01/02-v2 ? spu-console versions lower than version 2.0 cannot connect to sysmac spu units with unit versions of 2.0 or later. ? spu-console version 2.1 can be connected to sysmac spu units with unit versions earlier than 2.1, but the spu-console?s operati ons will be limited to spu- console operations for the lower unit version. ? microsoft .net framework 1.1 is required to connect to sysmac spu units with unit versions 1.0, 1.2, or 1.3. unit version of sysmac spu unit function unit ver. 1.0 unit ver. 1.2 unit ver. 1.3 unit ver. 2.0 unit ver. 2.1 data storage mode added as a sampling operat- ing mode. not supported supported scaling function for collection data not supported supported recording without specifying the number of records not supported supported terminology changes sampling condition setting record condition setting recipe function not supported supported expanded recipe function not supported not supported supported copy option not supported supported channel_block data type added not supported supported ftp communications not supported not supported supported unit version of sysmac spu unit spu-console version unit ver. 1.0 unit ver. 1.2 unit ver. 1.3 unit ver. 2.0 unit ver. 2.1 spu-console ver. 1.0 can be connected. cannot be connected. cannot be connected. cannot be connected. cannot be connected. spu-console ver. 1.2 can be connected, but operates as the unit version that is the same as the unit version of the unit. (operates as spu- console ver. 1.0.) can be connected. cannot be connected. cannot be connected. cannot be connected. spu-console ver. 1.3 can be connected, but operates as the unit version that is the same as the unit version of the unit. (operates as spu- console ver. 1.2.) can be connected. cannot be connected. cannot be connected. spu-console ver. 2.0 can be connected, but operates as the unit version that is the same as the unit version of the unit. (operates as spu- console ver. 1.3.) can be connected. can be connected. spu-console ver. 2.1 can be connected, but operates as the unit version that is the same as the unit version of the unit. (operates as spu- console ver. 2.0.) can be connected.
cs1w-spu01-v2/02-v2 11 external interface cs1w-spu01/spu02-v2 here, the cs1w-spu02-v2, which has two lan ports, is tak en as an example. the cs1w -spu01-v2 has only one lan port. name function unit number switch (unit no.) sets the unit number of the sysmac spu unit as a one-digit hexadecimal value. do not set the same unit number for more than one cpu bus unit under the same cpu unit. dip switch (dip sw) used for system settings. card button (card sw) press this button to allow the memory card inserted in the pc card slot to be removed. card eject button press to remove the pc card. card holder holds the pc card. select switch sets the command to be executed. the command number will be displayed on the seven-segment display. enter button executes the command set using the select switch. indicators the following indicators show the operating status of the unit: run, erc, erh, and comm. seven-segment display displays error information and the operating status of the sysmac spu unit. displays the command number when the select switch is operated. displays the ip address and other results of command execution. lan indicator indicates the operating status of the lan port. card indicator indicates the operating status of the pc card. pf-in indicator lights when the power failure input is received from a ups or other device. pc card slot a slot used to insert a card conforming to pc card type ii. communications ports lan1/lan2 lan communications ports. connect to 10base-t/100base-tx cables. comm port for future expansion. pf-in terminals connected to the power failure input from a ups or other device. recognition retry switch refer to the sysmac spu units operation manual (cat. no. 236), starting cpu unit operation immediately upon power application. spu02 lan1 lan2 lan1 lan2 card unit no. card sw comm pf-in dipsw select enter cs c s run r u n erc e r c erh e r h comm c o m m 0 unit number switch enter button select switch dip switch 7-segment display card eject button lan ports (cs1w-spu01-v2: one port, cs1w-spu02-v2: two ports) pf-in terminals comm port indicators card button card indicator pc card slot lan indicator card holder pf-in indicator recognition retry switch
cs1w-spu01-v2/02-v2 12 connecting the power failure signal cs1w-spu01/spu02-v2 connect the power failure signal output line from a ups or other dev ice to the power failure input terminals on the sysmac spu unit. note: tighten the cable screws to a torque of 0.3 nm. signal input specifications uninterruptive power supply for checking operation ? bu70xs (omron) operating temperature range: 0 to 40c ? bu606f (omron) operating temperature range: 0 to 55c item specification rated input voltage 24 vdc (+10% / -15%) input impedance 2 k ? input current 10 ma (typical) on voltage 17.4 v min. off voltage 5 v max. signals in com mc1.5/2-stf-3.81 (phoenix contact) internal circuits 2 k ? 510 ? in com 24 vdc input indicator
cs1w-spu01-v2/02-v2 13 dimensions (unit: mm) cs1w-spu01-v2 / cs1w-spu02-v2 note: the appearance varies with the model. related manuals name cat. no. contents cs1w-spu01-v2/spu02-v2 cj1w-spu01-v2 sysmac spu units operation manual v236 describes the installation and operation of the sysmac spu units. WS02-SPTC1-V2 spu-console ver. 2.1 operation manual v237 describes the installation and operation of the sysmac spu-console ver. 2.1. ws02-edmc1-v2 sysmac spu data management middleware user?s manual v232 describes the installation and operation of the sysmac spu data management middleware (edms). 101 35 130 20
r e a d a n d u n d e r s t a n d t h i s c a t a l o g p l e a s e r e a d a n d u n d e r s t a n d t h i s c a t a l o g b e f o r e p u r c h a s i n g t h e p r o d u c t s . p l e a s e c o n s u l t y o u r o m r o n r e p r e s e n t a t i v e i f y o u h a v e a n y q u e s t i o n s o r c o m m e n t s . w a r r a n t y a n d l i m i t a t i o n s o f l i a b i l i t y w a r r a n t y o m r o n ' s e x c l u s i v e w a r r a n t y i s t h a t t h e p r o d u c t s a r e f r e e f r o m d e f e c t s i n m a t e r i a l s a n d w o r k m a n s h i p f o r a p e r i o d o f o n e y e a r ( o r o t h e r p e r i o d i f s p e c i f i e d ) f r o m d a t e o f s a l e b y o m r o n . o m r o n m a k e s n o w a r r a n t y o r r e p r e s e n t a t i o n , e x p r e s s o r i m p l i e d , r e g a r d i n g n o n - i n f r i n g e m e n t , m e r c h a n t a b i l i t y , o r f i t n e s s f o r p a r t i c u l a r p u r p o s e o f t h e p r o d u c t s . a n y b u y e r o r u s e r a c k n o w l e d g e s t h a t t h e b u y e r o r u s e r a l o n e h a s d e t e r m i n e d t h a t t h e p r o d u c t s w i l l s u i t a b l y m e e t t h e r e q u i r e m e n t s o f t h e i r i n t e n d e d u s e . o m r o n d i s c l a i m s a l l o t h e r w a r r a n t i e s , e x p r e s s o r i m p l i e d . l i m i t a t i o n s o f l i a b i l i t y o m r o n s h a l l n o t b e r e s p o n s i b l e f o r s p e c i a l , i n d i r e c t , o r c o n s e q u e n t i a l d a m a g e s , l o s s o f p r o f i t s o r c o m m e r c i a l l o s s i n a n y w a y c o n n e c t e d w i t h t h e p r o d u c t s , w h e t h e r s u c h c l a i m i s b a s e d o n c o n t r a c t , w a r r a n t y , n e g l i g e n c e , o r s t r i c t l i a b i l i t y . i n n o e v e n t s h a l l t h e r e s p o n s i b i l i t y o f o m r o n f o r a n y a c t e x c e e d t h e i n d i v i d u a l p r i c e o f t h e p r o d u c t o n w h i c h l i a b i l i t y i s a s s e r t e d . i n n o e v e n t s h a l l o m r o n b e r e s p o n s i b l e f o r w a r r a n t y , r e p a i r , o r o t h e r c l a i m s r e g a r d i n g t h e p r o d u c t s u n l e s s o m r o n ' s a n a l y s i s c o n f i r m s t h a t t h e p r o d u c t s w e r e p r o p e r l y h a n d l e d , s t o r e d , i n s t a l l e d , a n d m a i n t a i n e d a n d n o t s u b j e c t t o c o n t a m i n a t i o n , a b u s e , m i s u s e , o r i n a p p r o p r i a t e m o d i f i c a t i o n o r r e p a i r . a p p l i c a t i o n c o n s i d e r a t i o n s s u i t a b i l i t y f o r u s e o m r o n s h a l l n o t b e r e s p o n s i b l e f o r c o n f o r m i t y w i t h a n y s t a n d a r d s , c o d e s , o r r e g u l a t i o n s t h a t a p p l y t o t h e c o m b i n a t i o n o f p r o d u c t s i n t h e c u s t o m e r ' s a p p l i c a t i o n o r u s e o f t h e p r o d u c t s . a t t h e c u s t o m e r ' s r e q u e s t , o m r o n w i l l p r o v i d e a p p l i c a b l e t h i r d p a r t y c e r t i f i c a t i o n d o c u m e n t s i d e n t i f y i n g r a t i n g s a n d l i m i t a t i o n s o f u s e t h a t a p p l y t o t h e p r o d u c t s . t h i s i n f o r m a t i o n b y i t s e l f i s n o t s u f f i c i e n t f o r a c o m p l e t e d e t e r m i n a t i o n o f t h e s u i t a b i l i t y o f t h e p r o d u c t s i n c o m b i n a t i o n w i t h t h e e n d p r o d u c t , machin e , s y s t e m , o r o t h e r a p p l i c a t i o n o r u s e . t h e f o l l o w i n g a r e s o m e e x a m p l e s o f a p p l i c a t i o n s f o r w h i c h p a r t i c u l a r a t t e n t i o n m u s t b e g i v e n . t h i s i s n o t i n t e n d e d t o b e a n e x h a u s t i v e l i s t o f a l l p o s s i b l e u s e s o f t h e p r o d u c t s , n o r i s i t i n t e n d e d t o i m p l y t h a t t h e u s e s l i s t e d m a y b e s u i t a b l e f o r t h e p r o d u c t s : o u t d o o r u s e , u s e s i n v o l v i n g p o t e n t i a l c h e m i c a l c o n t a m i n a t i o n o r e l e c t r i c a l i n t e r f e r e n c e , o r c o n d i t i o n s o r u s e s n o t d e s c r i b e d i n t h i s c a t a l o g . n u c l e a r e n e r g y c o n t r o l s y s t e m s , c o m b u s t i o n s y s t e m s , r a i l r o a d s y s t e m s , a v i a t i o n s y s t e m s , m e d i c a l e q u i p m e n t , a m u s e m e n t m a c h i n e s , v e h i c l e s , s a f e t y e q u i p m e n t , a n d i n s t a l l a t i o n s s u b j e c t t o s e p a r a t e i n d u s t r y o r g o v e r n m e n t r e g u l a t i o n s . s y s t e m s , m a c h i n e s , a n d e q u i p m e n t t h a t c o u l d p r e s e n t a r i s k t o l i f e o r p r o p e r t y . p l e a s e k n o w a n d o b s e r v e a l l p r o h i b i t i o n s o f u s e a p p l i c a b l e t o t h e p r o d u c t s . n e v e r u s e t h e p r o d u c t s f o r a n a p p l i c a t i o n i n v o l v i n g s e r i o u s r i s k t o l i f e o r p r o p e r t y w i t h o u t e n s u r i n g t h a t t h e s y s t e m a s a w h o l e h a s b e e n d e s i g n e d t o a d d r e s s t h e r i s k s , a n d t h a t t h e o m r o n p r o d u c t s a r e p r o p e r l y r a t e d a n d i n s t a l l e d f o r t h e i n t e n d e d u s e w i t h i n t h e o v e r a l l e q u i p m e n t o r s y s t e m . p r o g r a m m a b l e p r o d u c t s o m r o n s h a l l n o t b e r e s p o n s i b l e f o r t h e u s e r ' s p r o g r a m m i n g o f a p r o g r a m m a b l e p r o d u c t , o r a n y c o n s e q u e n c e t h e r e o f . d i s c l a i m e r s c h a n g e i n s p e c i f i c a t i o n s p r o d u c t s p e c i f i c a t i o n s a n d a c c e s s o r i e s m a y b e c h a n g e d a t a n y t i m e b a s e d o n i m p r o v e m e n t s a n d o t h e r r e a s o n s . i t i s o u r p r a c t i c e t o c h a n g e m o d e l n u m b e r s w h e n p u b l i s h e d r a t i n g s o r f e a t u r e s a r e c h a n g e d , o r w h e n s i g n i f i c a n t c o n s t r u c t i o n c h a n g e s a r e m a d e . h o w e v e r , s o m e s p e c i f i c a t i o n s o f t h e p r o d u c t s m a y b e c h a n g e d w i t h o u t a n y n o t i c e . w h e n i n d o u b t , s p e c i a l m o d e l n u m b e r s m a y b e a s s i g n e d t o f i x o r e s t a b l i s h k e y s p e c i f i c a t i o n s f o r y o u r a p p l i c a t i o n o n y o u r r e q u e s t . p l e a s e c o n s u l t w i t h y o u r o m r o n r e p r e s e n t a t i v e a t a n y t i m e t o c o n f i r m a c t u a l s p e c i f i c a t i o n s o f p u r c h a s e d p r o d u c t s . d i m e n s i o n s a n d w e i g h t s d i m e n s i o n s a n d w e i g h t s a r e n o m i n a l a n d a r e n o t t o b e u s e d f o r m a n u f a c t u r i n g p u r p o s e s , e v e n w h e n t o l e r a n c e s a r e s h o w n . p e r f o r m a n c e d a t a perfor m a n c e d a t a g i v e n i n t h i s c a t a l o g i s p r o v i d e d a s a g u i d e f o r t h e u s e r i n d e t e r m i n i n g s u i t a b i l i t y a n d d o e s n o t c o n s t i t u t e a w a r r a n t y . i t m a y r e p r e s e n t t h e r e s u l t o f o m r o n ? s t e s t c o n d i t i o n s , a n d t h e u s e r s m u s t c o r r e l a t e i t t o a c t u a l a p p l i c a t i o n r e q u i r e m e n t s . a c t u a l p e r f o r m a n c e i s s u b j e c t t o t h e o m r o n w a r r a n t y a n d l i m i t a t i o n s o f l i a b i l i t y . e r r o r s a n d o m i s s i o n s t h e i n f o r m a t i o n i n t h i s d o c u m e n t h a s b e e n c a r e f u l l y c h e c k e d a n d i s b e l i e v e d t o b e a c c u r a t e ; h o w e v e r , n o r e s p o n s i b i l i t y i s a s s u m e d f o r c l e r i c a l , t y p o g r a p h i c a l , o r p r o o f r e a d i n g e r r o r s , o r o m i s s i o n s . 2010 . 1 i n t h e i n t e r e s t o f p r o d u c t i m p r o v e m e n t , s p e c i f i c a t i o n s a r e s u b j e c t t o c h a n g e w i t h o u t n o t i c e . o m r o n c o r p o r a t i o n i n d u s t r i a l a u t o m a t i o n c o m p a n y h t t p : / / w w w . i a . o m r o n . c o m / ( c ) c o p y r i g h t o m r o n c o r p o r a t i o n 2 0 1 0 a l l r i g h t r e s e r v e d .


▲Up To Search▲   

 
Price & Availability of WS02-SPTC1-V2

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X