  agilent U1230 series handheld digital multimeter (dmm) data sheet whether it is dark, noisy or even dangerous, the U1230 series handheld digital multimeter keeps you equipped with features that anticipate worst- case scenarios. the ergonomic shaped handheld allows you to single-handedly illuminate the test area with a built-in flashlight while selecting measurement functions using the rotary dial. vsense performs non-contact voltage detection while continuity detection is made easy with the audible beeper alert and flashing backlight display. with the U1230 series, you work better in the conditions you are in. ? built-in led flashlight to illuminate test area ? flashing backlight as additional visual alert during continuity tests in noisy environments ? vsense to perform non-contact voltage detection ? data logging capability (stores up to 10 readings) ? ir-to-usb connectivity to transfer data to pc for record ergonomically shaped with a built-in flashlight built for handheld users working in a poorly lit environment, the U1230 series allows you to single-handedly illuminate your test area while making measurements with its easily activated built-in flashlight. its ergonomic shape fits your hand, while the easily accessible rotary dial allows selection of measurement functions. flashing backlight and beeping alert for continuity detection the U1230 series is built for con- tinuity detection in dark and noisy environments. its audible beep and flashing backlight display provides increased visual and audio alert to indicate continuity. non-contact voltage detection with vsense the vsense, a unique feature found in the u1233 series performs non-contact voltage detection. it delivers more safety while making measurements in dangerous working environments by avoiding any contact with hot or live wires. upon detection of voltage, it produces a unique combination of beeping alert and blinking led light to make measure- ments more efficiently C especially in a dark or noisy environment. features
2 take a closer look low input impedance to eliminate ghost voltage measurement anti-slip rotary dial for easy measurement function selection flashing light and audible beep during presence of voltage 1 bar graph indication and frequency measurement path vsense performs non-contact voltage detection 1 ease viewing with display backlight or built-in flashlight figure 1. U1230 series front view freezes and stores current measurement value allows flexibility to change measurement range figure 2. the built-in flashlight as illustrated notes: 1. only applicable for the u1233 series
3 electrical specifications dc specifications function range resolution accuracy (% of reading + counts of least significant digit) test current burden voltage/ shunt input impedance u1231a/u1232a/ u1233a where (applicable) where (applicable) where (applicable) voltage 600 mv 1 0.1 mv 0.5% + 2 na na 11.18 m 6 v 0.001 v 0.5% + 2 na na 11.18 m 60 v 0.01 v 0.5% + 2 na na 10.1 m 600 v 0.1 v 0.5% + 2 na na 10 m 600 v (vz low ) 2 0.1 v 2% + 3 na na 3 k resistance 600 4 0.1 0.9% + 3 0.57 ma na na 6 k 4 0.001 k 0.9% + 3 57 a na na 60 k 0.01 k 0.9% + 3 5.7 a na na 600 k 0.1 k 0.9% + 3 570 na na na 6 m 5 0.001 m 0.9% + 3 100 na/10 m na na 60 m 5 0.01 m 1.5% + 3 100 na/10 m na na diode 3 2 v 0.001 v 0.9% + 2 0.57 ma na na current 60 a 1 0.01 a 1.0% + 2 4 na < 2.5 v/1 k na 600 a 1 0.1 a 1.0% + 2 4 na < 2.5 v/1 k na 6 a 2 0.001 a 1.0% + 3 4 na < 0.2 v/0.005 na 10 a 2, 3 0.01 a 1.0% + 3 4 na < 0.4 v/0.005 na notes for dc voltage specifications: 1. the accuracy of the 600 mv range is specified after the null function is used to subtract the thermal effect (by shorting th e test leads). 2. for vz low (low input impedance) measurements, auto-ranging is disabled and the multimeters range is set to 600 v in the manual ranging mode. notes for resistance specifications: 1. overload protection: 600 vrms for short circuits with < 0.3 a current. 2. maximum open voltage is < +3 v. 3. built-in buzzer beeps when the resistance measured is less than 23 10 . the multimeter can capture intermittent measure ments longer than 1?ms. 4. the accuracy of the 600 to 6 k range is specified after the null function is used to subtract the test lead resistance an d thermal effect (by shorting the test leads). 5. for the ranges of 6 m and 60 m, the rh is specified for < 60%. notes for diode specifications: 1. overload protection: 600 vrms for short circuits with < 0.3 a current. 2. built-in buzzer beeps continuously when the voltage measured is less than 50 mv and beeps once for forward-biased diode or s emiconductor junctions measured between 0.3 v and 0.8 v (0.3 v reading 0.8 v). 3. open voltage for diode: < +3 v dc. 4. the maximum display for diode measurements is 2100 counts. notes for dc current specifications: 1. overload protection for 60 a to 600 a range: 600 vrms for short circuits with < 0.3 a current. 2. overload protection for 6 a to 10 a range: 11 a/1000 v; 10 38 mm fast-acting fuse. 3. specification for 10 a range: 10 a continuous. add 0.3% to the specified accuracy when measuring signals > 10 a to 20 a for 30 seconds maximum. after measuring currents > 10 a, cool down the multimeter for twice the duration of the measured time before proceeding with low curr ent measurements. 4. only applicable for the u1232/u1233 series
4 electrical specifications ac specifications true rms ac voltage and ac current specifications function range resolution accuracy (% of reading + counts of least significant digit) burden voltage/ shunt 45 hz to 500 hz 500 hz to 1 khz where (applicable) voltage 600 mv 0.1 mv 1.0% + 3 2.0% + 3 na 6 v 0.001 v 1.0% + 3 2.0% + 3 na 60 v 0.01 v 1.0% + 3 2.0% + 3 na 600 v 0.1 v 1.0% + 3 2.0% + 3 na 600 (vz low ) 3 0.1 v 2.0% + 3 4.0% + 3 na current 1 60 a 2 0.01 a 1.5% + 3 na < 2.5 v/1 k 600 a 2 0.1 a 1.5% + 3 na < 2.5 v/1 k 6 a 3 0.001 a 1.5% + 3 na < 0.2 v/0.005 10 a 3, 4 0.01 a 1.5% + 3 na < 0.4 v/0.005 notes for true rms ac voltage specifications: 1. overload protection: 600 vrms. for millivolt measurements, 600 vrms for short circuits with < 0.3 a current. 2. input impedance: 10 m (nominal) in parallel with < 100 pf. 3. vz low input impedance: 3 k (nominal). notes for ac current specifications: 1. ac current measurement not available for u1231a model. 2. overload protection for 60 a to 600 a range: 600 vrms for short circuits with < 0.3 a current. 3. overload protection for 6 a to 10 a range: 11 a/1000 v; 10 38 mm fast-acting fuse. 4. specification for 10 a range: 10 a continuous. add 0.3% to the specified accuracy when measuring signals > 10 a to 20 a for 30 seconds maximum. after measuring currents > 10 a, cool down the multimeter for twice the duration of the measured time before proceeding with lo w current measurements. capacitance specifications range resolution accuracy (% of reading + counts of least significant digit) measuring rate (at full scale) u1231a/u1232a/u1233a 1000 nf 1 nf 1.9% + 2 4 times/second 10 f 0.01 f 1.9% + 2 4 times/second 100 f 0.1 f 1.9% + 2 4 times/second 1000 f 1 f 1.9% + 2 1 time/second 10 mf 0.01 mf 1.9% + 2 0.1 time/second notes : 1. overload protection: 600 vrms for short circuits with < 0.3 a current. 2. the accuracy of for all ranges is specified based on a film capacitor or better, and after the null function is used to subt ract the test lead resistance and thermal effect (by shorting the test leads). 3. the maximum display is 1200 counts.
5 electrical specifications temperature specifications thermal type range resolution accuracy (% of reading + counts of least significant digit) u1233a k C40 c to 1372 c 0.1 c 1% + 1 c C40 f to 2502 f 0.1 f 1% + 1.8 f notes: 1. the specification above is specified after 60 minutes of warm up time. if the unit is exposed during storage in high humidit y (condensing) environment, 120 minutes of operating time is required instead. 2. the accuracy does not include the tolerance of the thermocouple probe. 3. do not allow the temperature sensor to contact a surface that is energized above 30 vrms or 60 v dc. such voltages poses a s hock hazard. 4. ensure that the ambient temperature is stable within 1 oc and that the null function is used to reduce the test leads ther mal effect and temperature offset. before using null function, set the multimeter to measure temperature without ambient compensation (c) and keep the th ermocouple probe as close as possible to the multimeter (avoid contact with any surface that has a different temperature from the ambient temper ature). 5. when measuring temperature with respect to any temperature calibrator, try to set both the calibrator and multimeter with an external reference (without internal ambient compensation). if both the calibrator and multimeter are set with internal reference (with internal a mbient compensation), some deviations may show between the readings of the calibrator and multimeter, this difference is caused from the calibrator a nd multimeterss ambient compensation. the deviation can be reduced by keeping the multimeter close to the output terminal of calibrator. 6. the temperature calculation is specified according to the safety standards of en/iec-60548-1and nist175. 7. the approximate ambient temperature (cold-junction compensation) is shown on the display when you have an open thermocouple. the open thermocouple message may be due to broken (open) probe or because no probe is installed into the input jacks of the multimeter. frequency specifications range resolution accuracy (% of reading + counts of least significant digit) minimum input frequency u1231a/u1232a/u1233a 99.99 hz 0.01 hz 0.1% + 2 5 hz 999.9 hz 0.1 hz 0.1% + 2 9.999 khz 1 hz 0.1% + 2 99.99 khz 10 hz 0.1% + 2 notes: 1. overload protection: 600 v; input signal is < 20,000,000 v hz (product of voltage and frequency).
6 electrical specifications frequency sensitivity specifications for voltage measurements input range minimum sensitivity (rms sine wave) maximum input for specified accuracy 1 5 hz to 50 khz u1231a u1232a u1233a 600 mv in scale mode 50 mv 50 mv 50 mv 600 mv 120 mv 120 mv 120 mv 6 v 0.6 v 0.6 v 0.6 v 60 v 5.0 v 5.0 v 5.0 v 600 v 50 v 50 v 50 v notes: 1. maximum input for specified accuracy, refer to ac specifications on page 106 of the user guide. for current measurements input range minimum sensitivity (rms sine wave) maximum input for specified accuracy 1 45 hz to 5 khz u1232a u1233a 60 a 30 a 30 a 600 a 30 a 30 a 6 a 0.5 a 0.5 a 10 a 0.5 a 0.5 a notes: 1. maximum input for specified accuracy, refer to ac specifications on page 106 of the user guide. scale transfer (mv) range resolution accuracy (% of reading + counts of least significant digit) u1231a/u1232a/u1233a dc 600 mv 0.1 mv 0.5% + 2 2 ac 600 mv 0.1 mv 1.0 % + 3 @ 45 hz to 500 hz 2.0 % + 3 @ 500 hz to 1 khz notes: 1. overload protection: 600 vrms for short circuits with < 0.3 a current. 2. the accuracy of the dc 600 mv range is specified after the null function is used to subtract the thermal effect (by shorting the test leads). 3. input impedance: 10 m (typical).
7 electrical specifications display update rate (approximate) function times/second u1231a u1232a/u1233a ac v (v or mv) 5 5 dc v (v or mv) 5 5 ac v/dc v (vz low )1 1 scale transfer (mv) 5 5 5 5 diode 5 5 capacitance 4 (< 100 f) 4 (< 100 f) dc a (a, ma, or a) na 5 ac a (a, ma, or a) na 5 frequency 1 (> 10 hz) 1 (> 10 hz)
8 general specifications parameter u1231a/u1232a/u1233a power supply battery type ? 4 1.5 v aaa alkaline battery (ansi/neda 24a or iec lr03), or ? 4 1.5 v aaa zinc chloride battery (ansi/neda 24d or iec r03) battery life ? 500 hours typical (based on new alkaline batteries) with backlight and flashlight disabled low battery indication ? low battery indicator will flash when the battery voltage drops below approximately 4.4 v power consumption 450 mva maximum (with backlight and flashlight enabled) fuse 10 38 mm 11 a/1000 v fast-acting fuse display liquid crystal display (lcd) (with maximum reading of 6600 counts) operating environment ? operating temperature from C10 c to 55 c, 0% to 80% rh ? full accuracy up to 80% rh for temperatures up to 30 c, decreasing linearly to 50% rh at 55 c ? altitude up to 2000 meters ? pollution degree ii storage compliance C40 c to 60 c, 0% to 80% rh without batteries safety compliance en/iec 61010-1:2001, ansi/ul 61010-1:2004, and can/csa-c22.2 no. 61010-1-04 measurement category cat iii 600 v electromagnetic compatibility (emc) commercial limits compliance with en61326-1 temperature coefficient 0.1 (specified accuracy) / c (from C10 c to 18 c, or 28 c to 55 c) common mode rejection ratio (cmrr) > 100 db at dc, 50/60 hz (1 k unbalanced) normal model rejection ration (nmrr) > 60 db at 50/60 hz dimensions (h x w x d) 169 mm 86 mm 52 mm weight u1232a and u1233a: 371 grams (with batteries and holster) u1231a: 365 grams (with batteries and holster) warranty ? three years for product 1 ? three months for products accessories calibration cycle one year notes: 1. please take note that for the product, the warranty does not cover: ? damage from contamination ? normal wear and tear of mechanical components ? manuals, fuses, and batteries specification assumptions ? accuracy is given as (% of reading + counts of least significant digit) at 23 c 5 c, with relative humidity less than 8 0% rh. ? ac v and ac a specifications are ac coupled, true rms and are valid from 5% of range to 100% of range. ? the crest factor may be up to 3.0 at full- scale (4000 counts) ? for non- sinusoidal waveforms, add (2% reading + 2% full scale) typical. ? after vz low (low input impedance) voltage measurements, wait at least 20 minutes for thermal impact to cool before proceeding with any other measurement.
9 ordering information standard shipped items standard u1231a, u1232a and u1233a include: ? quick start guide ? certificate of calibration (coc) ? u1167a 4 mm tips probes test leads ? 4 x 1.5 v batteries recommended accessories u1174a soft carrying case u1168a standard test lead kit u1173a ir-to-usb cable u1171a magnetic hanging kit
www.agilent.com www.agilent.com/find/dmm agilent email updates www.agilent.com/find/emailupdates get the latest information on the products and applications you select. www.lxistandard.org lan extensions for instruments puts the power of ethernet and the web inside your test systems. agilent is a founding member of the lxi consortium. agilent channel partners www. agilent .com/find/ channelpartners get the best of both worlds: agilents measurement expertise and product breadth, combined with channel partner convenience. www.axiestandard.org advancedtca ? extensions for instrumentation and test (axie) is an open standard that extends the advancedtca ? for general purpose and semiconductor test. agilent is a founding member of the axie consortium. http://www.pxisa.org pci extensions for instrumentation (pxi) modular instrumentation delivers a rugged, pc-based high- performance measurement and automation system. agilent advantage services is com- mitted to your success throughout your equipments lifetime. we share measurement and service expertise to help you create the products that change our world. to keep you com- petitive, we continually invest in tools and processes that speed up calibra- tion and repair, reduce your cost of ownership, and move us ahead of your development curve. www.agilent.com/quality www.agilent.com/find/advantageservices for more information on agilent technologies products, applications or services, please contact your local agilent office. the complete list is available at: www.agilent.com/find/contactus americas canada (877) 894 4414 brazil (11) 4197 3500 mexico 01800 5064 800 united states (800) 829 4444 asia pacific australia 1 800 629 485 china 800 810 0189 hong kong 800 938 693 india 1 800 112 929 japan 0120 (421) 345 korea 080 769 0800 malaysia 1 800 888 848 singapore 1 800 375 8100 taiwan 0800 047 866 other ap countries (65) 375 8100 europe & middle east belgium 32 (0) 2 404 93 40 denmark 45 70 13 15 15 finland 358 (0) 10 855 2100 france 0825 010 700* *0.125 /minute germany 49 (0) 7031 464 6333 ireland 1890 924 204 israel 972-3-9288-504/544 italy 39 02 92 60 8484 netherlands 31 (0) 20 547 2111 spain 34 (91) 631 3300 sweden 0200-88 22 55 united kingdom 44 (0) 118 9276201 for other unlisted countries: www.agilent.com/find/contactus revised: october 14, 2010 product specifications and descriptions in this document subject to change without notice. ? agilent technologies, inc. 2011 printed in usa, may 6, 2011 5990-7550en