120 1-800-526-2324 ? www.us.tdk-lambda.com/lp/ disclaimer: us.tdk-lambda.com/lp/legal.htm z+ series features u 2u high u built-in usb, rs-232 & rs-485 interface u optional lan, gpib & isolated analog programming u bench or rack mount u constant current or voltage modes u five year warranty 200 to 800w programmable power supplies key market segments & applications voltage current max ripple noise ripple ef? ciency front panel adjust adjust power 5hz-1mhz 20mhz bw 5hz-1mhz % output jacks model range range (w) (mv) (mv) (ma) (100-200vac) (option) Z10-20-U 0 - 10 0 - 20 200 5 50 50 80 / 82 yes z10-40-u 0 - 10 0 - 40 400 5 50 50 80 / 82 yes z10-60-u 0 - 10 0 - 60 600 6.25 75 75 80 / 82 yes z10-72-u 0 - 10 0 - 72 720 6.25 75 75 80 / 82 yes z20-10-u 0 - 20 0 - 10 200 5 50 30 82 / 84 yes z20-20-u 0 - 20 0 - 20 400 5 50 30 81 / 83 yes z20-30-u 0 - 20 0 - 30 600 6.25 75 45 82 / 84 yes z20-40-u 0 - 20 0 - 40 800 6.25 75 45 82 / 84 yes z36-6-u 0 - 36 0 - 6 216 5 50 15 83 / 85 yes z36-12-u 0 - 36 0 - 12 432 5 50 15 83 / 85 yes z36-18-u 0 - 36 0 - 18 648 6.25 75 22 84 / 85 yes z36-24-u 0 - 36 0 - 24 864 6.25 75 22 84 / 85 yes z60-3.5-u 0 - 60 0 - 3.5 210 5 50 8 83 / 85 yes z60-7-u 0 - 60 0 - 7 420 5 50 8 83 / 85 yes z60-10-u 0 - 60 0 - 10 600 6.25 75 12 83 / 85 yes z60-14-u 0 - 60 0 - 14 840 6.25 75 12 83 / 85 yes z100-2-u 0 - 100 0 - 2 200 8 80 3 83 / 85 no z100-4-u 0 - 100 0 - 4 400 8 80 3 84 / 86 no z100-6-u 0 - 100 0 - 6 600 10 100 4.5 84 / 86 no z100-8-u 0 - 100 0 - 8 800 10 100 4.5 84 / 86 no model selector part number 19 rack housing (accepts four 105mm width units or six 70mm width units) z-nl100 blanking panel for 19 rack (70mm) z-bp blanking panel for 19 rack (105mm) z-wbp dual/triple housing (accepts two 105mm case units or three 70mm case u nits) z-nl200 serial link cable (one is included with each power supply) z-rj45 communication cable rs485 z-485-9 communication cable rs232 z-232-9 north american line cord (one included with -u suf ? x) z-u accessories option code front panel terminals (60v or 24a max)* -l only one of the options below can be included: gpib interface* -ieee voltage programming isolated analog interface* -is510 current programming isolated analog interface* -is420 lan interface (complies with lxi class c) -lan *requires wide body (105mm) case style factory installed options z10-20-lan-l-u part number example
121 1-800-526-2324 ? www.us.tdk-lambda.com/lp/ revision a6: sep 2012 z+ series model z10 z20 z36 z60 z100 load regulation cv 2mv + 0.01% of rated voltage over 0 - 100% load change line regulation cv 2mv + 0.01% of rated voltage over a 85 - 132 or 170 - 265vac line change recovery time (1) cv 1ms temperature coef? cient cv 30ppm/c following 30 minute warm up temperature stability cv 0.02% of rated voltage over 8 hours following 30 minute warm up time warm up drift (2) cv <0.05% of rated voltage + 2mv of rated output voltage up programming response time (10-90% or 90-10% of vmax) cv 15ms 30ms 30ms 50ms 50ms down programming resp time (cv) (10-90% or 90-10% of vmax) full load 10ms 30ms 30ms 50ms 50ms down programming resp time (cv) (90-10% of vmax) zero load 190ms 200ms 250ms 310ms 900ms load regulation cc 5ma + 0.01% of rated current over 0 - 100% vout change load regulation thermal drift cc < 0.05% of rated current over 30 minutes after load change line regulation cc 2ma + 0.01% of rated current over a 85 - 132 or 170 - 265vac line change temperature coef? cient cc 100ppm/c of rated current after 30 minute warm up time temperature stability cc 0.05% of rated current over 8 hours following 30 minute warm up time warm up drift (2) cc <0.1% of rated current vout & iout programming & readback resolution digitally < 0.012% of rated voltage/current vout & iout programming & readback accuracy digitally < 0.05% of rated voltage, < 0.1% of rated current voltage & current programming analog by either voltage (0-5v or 0-10v) or resistance (0-5k or 0-10k) voltage & current monitoring analog 0-5v or 0-10v voltage (user selectable), 1% accuracy overvoltage shutdown (user programmable) v 0.5 - 12 1 - 24 2 - 40 5 - 66 5 - 110 overtemperature protection - user selectable - latched or non-latching display - voltage - 4 digits. accuracy 0.5% of rated voltage or current 1 count remote on/off - by applied voltage or dry contact relay (user selectable logic) output good - open collector, low on fail remote sense compensation (per wire) v 1 1 2 3 5 communication interface - rs232, rs485 & usb standard, ieee488 (gpib) & lan optional series operation - up to two identical units (with external diodes) parallel operation - up to six units in master-slave con? guration input voltage / frequency (3) - 85-265vac, 47-63hz inrush current - < 25a hold up time (typical) ms 16ms power factor correction - complies with en61000-3-2 class a (0.99 typ) operating temperature c 0 - 50c storage temperature c -20 to +85c humidity (non condensing) %rh operating: 10 - 90%rh, storage 10 - 95%rh cooling - internal temperature controlled fan withstand voltage - i/p to gnd 2kvac, i/p to o/p 3kvac, o/p to gnd 1380vdc 1 min insulation resistance - >100m at 25c & 70%rh vibration (non operating) - iec60068-2-64 shock - <20g, half sine, 11ms. iec60068-2-27 safety agency certi? cations - ul61010-1, en61010-1, iec61010 (designed to meet ul/en60950-1) immunity - iec61326 (designed to meet en55022 / en55024) conducted & radiated emi - en55022-b, fcc part 15-b, vcci-b size (h x w x d) (excluding handles and busbars) mm standard body 83 x 70 x 350mm; wide body 83 x 105 x 350mm weight kg standard body 1.9kg; wide body 2.4kg warranty yrs five years speci? cations (see website for detailed speci? cations) notes: (1) recovery to within 0.5% of rated voltage after a load change of 10-90% (output current 10-100% of imax) (2) over 30 minute warm up time after power on (3) derate for 85-100 vac; z10-72-u (66a), z20-40-u (36a), z36-24-u (20a), z60-14-u (12.5a), z100-8-u (7.5a) for additional information, please visit us.tdk-lambda.com/lp/products/zplus-series.htm
|