  cui .com date 03/20/2013 page 1 of 6 date page 1 of 6 features ? 1 w isolated output ? smaller package ? single regulated output ? 3,000 vdc isolation ? continuous short circuit, over current protection ? temperature range (-40~105c) ? high efficiency at light load ? efficiency up to 82% model input voltage output voltage output current output power ripple and noise 1 effciency typ (vdc) range (vdc) (vdc) min (ma) max (ma) max (w) max (mvp-p) typ (%) prmc1-d5-s5-s 5 4.5~9 5 10 200 1 75 72 prmc1-d5-s12-s 5 4.5~9 12 4 83 1 75 77 prmc1-d5-s15-s 5 4.5~9 15 3 67 1 75 77 prmc1-d12-s5-s 12 9~18 5 10 200 1 75 76 prmc1-d12-s12-s 12 9~18 12 4 83 1 75 80 prmc1-d12-s15-s 12 9~18 15 3 67 1 75 81 prmc1-d24-s5-s 24 18~36 5 10 200 1 75 76 prmc1-d24-s12-s 24 18~36 12 4 83 1 75 81 prmc1-d24-s15-s 24 18~36 15 3 67 1 75 81 prmc1-d24-s24-s 24 18~36 24 6 42 1 75 82 prmc1-d48-s5-s 48 36~75 5 10 200 1 75 76 PRMC1-D48-S12-S 48 36~75 12 4 83 1 75 81 prmc1-d48-s15-s 48 36~75 15 3 67 1 75 81 notes: 1. ripple and noise are measured at 20 mhz bw by parallel cable method part number key prmc1 - d xx - s xx -s input voltage output voltage packaging style base number sip series : prmc1-s description: dc-dc converter
cui .com date 03/20/2013 page 2 of 6 input parameter conditions/description min typ max units operating input voltage 5 v input models 12 v input models 24 v input models 48 v input models 4.5 9 18 36 5 12 24 48 9 18 36 75 vdc vdc vdc vdc start-up voltage 5 v input models 12 v input models 24 v input models 48 v input models 3.5 4.5 11 24 4 8 16 33 4.5 9 18 36 vdc vdc vdc vdc surge voltage for maximum of 1 second 5 v input models 12 v input models 24 v input models 48 v input models -0.7 -0.7 -0.7 -0.7 12 25 50 100 vdc vdc vdc vdc flter capacitance flter output parameter conditions/description min typ max units line regulation full load, input voltage from low to high 0.2 0.5 % load regulation 5% to 100% load 0.4 0.75 % voltage accuracy 5% to 100% load 1 3 % no-load output voltage accuracy 5v output models all other models 1.5 1.5 5 3 % % switching frequency 100% load, nominal input voltage 180 khz transient recovery time 25% load step change 0.5 1 ms transient response deviation 25% load step change 3 5 % temperature coeffcient 100% load 0.02 0.03 %/c protections parameter conditions/description min typ max units short circuit protection continuous, automatic recovery over current protection 120 % safety and compliance parameter conditions/description min typ max units isolation voltage for 1 minute at 1 ma max. 3,000 vdc isolation resistance at 500 vdc 1,000 m? conducted emissions cispr22/en55022, class b, (external circuit required, see figure 1-b) radiated emissions cispr22/en55022, class b, (external circuit required, see figure 1-b) esd 1 iec/en61000-4-2, class b, contact 4kv/ air 8kv radiated immunity iec/en61000-4-3, class a, 10v/m eft/burst iec/en61000-4-4, class b, 2kv (external circuit required, see figure 1-a) surge iec/en61000-4-5, class b, 2kv (external circuit required, see figure 1-a) conducted immunity iec/en61000-4-6, class a, 3 vr.m.s voltage dips and interruptions iec/en61000-4-29, class b, 0%-70% mtbf as per mil-hdbk-217f @ 25c 1,000,000 hours rohs compliant yes note: 1. 24v input models can only meet esd contact 2kv with external circuit 1-c hooked up. 24v input models can meet esd contact 4kv with external circuit 1-a, 1-b, and 1-c hooked up. cui inc series : prmc1-s description: dc-dc converter
cui .com date 03/20/2013 page 3 of 6 23 56 78 1 23 56 78 1 front view bottom view top view pcb layou t grid size: 2.54mm x 2.54mm 0.50[0.020 ] 2.54[0.100] 4.10 [0.161 ] 12.0 0 [0.472] 22.00 [0.866] 0.30 [0.012] 0.50[0.020 ] 17.78 [0.700 ] 2.50 [0.098 ] 9.50 [0.374 ] ?1.00 [0.039] mechanical parameter conditions/description min typ max units dimensions 22.00 x 9.50 x 12.00 (0.866 x 0.374 x 0.472 inch) mm case material plastic (ul94-v0) weight 4.92 g pin connections pin function 1 gnd 2 vin 3 ctrl 5 nc 6 +vo 7 0v 8 cs mechanical drawing units: mm[inch] tolerance: 0.25[0.010] pin section tolerance: 0.10[0.004] parameter conditions/description min typ max units hand soldering 1.5 mm from case for 10 seconds 300 c wave soldering see wave soldering profle 260 c parameter conditions/description min typ max units operating temperature see derating curve -40 105 c storage temperature -55 125 c storage humidity non-condensing 95 % temperature rise at full load, ta=25c 25 c solderability environmental cui inc series : prmc1-s description: dc-dc converter
cui .com date 03/20/2013 page 4 of 6 recommended external circuit components vin (vdc) 5 12 24 48 fuse choose according to practical input current mov tbd -- 10d560 10d101 ldm1 tbd -- 56h 56h tvs tbd smcj28a smcj48a smcj90a c0 tbd 680f/25v 120f/50v 120f/100v c1 tbd 4.7f/50v 4.7f/50v 4.7f/100v ldm2 tbd 12h 12h 12h c2 tbd 4.7f/50v 4.7f/50v 4.7f/100v cy tbd 1nf 1nf 1nf d1 tbd rb160m-60/1a rb160m-60/1a rb160m-60/1a r follows: aaaaa aaaaaaaaaaaa cd 47nf/50v 47nf/50v 47nf/50v 47nf/50v emc recommended circuit derating curves 100 80 60 40 20 ambient t emper ature (c) load (% ) -40- 20 02 04 06 0 85 105 120 sa fe operating area cy rl ld m2  c0 tv s ld m1 mo v fu se c1 + vi n gn d +v o 0v eu t c2 ct rl cd d1 r ct vi n gn d load (a) (b) (c) 10 sec. max. wa ve soldering time 4 sec. max. pe ak t emp. 260c max. time (sec.) t emper ature (c) 250 200 150 100 50 0 wave soldering profle temperature derating curve 300 0 . 1 ? ? ? = c d c i v v r figure 1 test configuration dc ci n li n dc load os ci ll os co pe cu rr en t pr ob e li n( 4. 7 h) ci n( 22 0 f, es r< 1. 0 at 100k hz ) note: input refected-ripple current is measured with an inductor lin and capacitor cin to simulate source impedance. external components lin 4.7h cin 220f, esr < 1.0? at 100 khz cui inc series : prmc1-s description: dc-dc converter
cui .com date 03/20/2013 page 5 of 6 1. output load requirement to ensure this module can operate effciently and reliably, the minimum output load may not be less than 5% of the full load during operation. if the actual output power is low, connect a resistor at the output end in parallel to increase the load. 2. recommended circuit this series has been tested according to the following recommended testing circuit before leaving the factory. this series should be tested under load (see figure 2). if you want to further decrease the input/output ripple, you can increase the capacitance accordingly or choose capacitors with low esr. however, the capacitance of the output flter capacitor must be appropriate. if the capacitance is too high, a startup problem might arise. for every channel of the output, to ensure safe and reliable operation, the maximum capaci - tance must be less than the maximum capacitive load (see table 1). 3. ctrl terminal when open or applied high impedance, the converter will turn on. when its pulled high, the converter will shutdown. the input cur - rent should between 5-10ma. exceeding the maximum 20ma will cause permanent damage to the converter. the value for r can be derived as follows: 4. input current when it is used in an unregulated condition, make sure that the input fuctuations and ripple voltage do not exceed the module stan - dard. refer to figure 3 for the startup current of this dc-dc module. application notes figure 2 figure 3 table 1 vin (vdc) cin (f) lin (h) cs (f) cout (f) 5 100 4.7-120 10-22 47 12 100 4.7-120 10-22 47 24 10 4.7-120 10-22 47 48 10 4.7-120 10-22 47 300 0 . 1 ? ? ? = c d c i v v r ra ng e in pu tv olta ge in p ut c ur re nt(a ) in pu tv ol tage (v ) ip vin (vdc) ip (ma) 5 470 12 180 24 110 48 42 9r 9 &rxw    &v &lq 9lq *1'    9f 5 /lq ,f ' &g note: 1. minimum load shouldn't be less than 5%, otherwise ripple may increase dramatically. operation under minimum load will not damage the converter, however, they may not meet all specifcations listed. 2. maximum capacitive load is tested at input voltage range and full load. 3. all specifcations are measured at ta=25c, humidity<75%, nominal input voltage and rated output load unless otherwise specifed. cui inc series : prmc1-s description: dc-dc converter
date 03/20/2013 page 6 of 6 cui offers a two (2) year limited warranty. complete warranty information is listed on our website. cui reserves the right to make changes to the product at any time without notice. information provided by cui is believed to be accurate and reliable. however, no responsibility is assumed by cui for its use, nor for any infringements of patents or other rights of third parties which may result from its use. cui products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. a critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness. headquarters 20050 sw 112th ave. tualatin, or 97062 800.275.4899 fax 503.612.2383 cui .com techsupport@cui.com rev. description date 1.0 initial release 03/20/2013 the revision history provided is for informational purposes only and is believed to be accurate. revision history cui inc series : prmc1-s description: dc-dc converter


▲Up To Search▲   

 
Price & Availability of PRMC1-D48-S12-S

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X