Part Number Hot Search : 
5224B 13012 VN820SP 2EZ47 FMM50 V16L25JI UM7441 Z0103M
Product Description
Full Text Search
 

To Download OS150-USB22 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  os150 usb 2.2 ir t emperature sensors ? e-mail: info@omega.com for latest product manuals: omegamanual.info shop online at omega.com ? u ser ?s guide ? made in united kingdom www.datasheet.co.kr datasheet pdf - http://www..net/
servicing north america: u.s.a.: one omega drive, box 4047 iso 9001 certified stamford ct 06907-0047 tel: (203) 359-1660 fax: (203) 359-7700 e-mail: info@omega.com canada: 976 bergar laval (quebec) h7l 5a1, canada tel: (514) 856-6928 fax: (514) 856-6886 e-mail: info@omega.ca for immediate technical or application assistance: u.s.a. and canada: sales service: 1-800-826-6342/1-800-tc-omega ? customer service: 1-800-622-2378/1-800-622-best ? engineering service: 1-800-872-9436/1-800-usa-when ? mexico: en espan ? ol: (001) 203-359-7803 fax: (001) 203-359-7807 e-mail: espanol@omega.com info@omega.com.mx servicing europe: benelux : managed by the united kingdom office toll-free: 0800 099 3344t el: +31 20 347 21 21 fax: +31 20 643 46 43 e-mail: sales@omegaeng.nl czech republic: frystatska 184, 733 01 karvina , czech republic tel: +4 20 (0)5 9 6311899 fax: +420 (0)5 9 6311114 toll free: 0800-1-66342 e-mail: info@omegashop.cz germany/austria: daimlerstrasse 26, d-75392 deckenpfronn, germany tel: +49 (0)7056 9398-0 fax: +49 (0)7056 9398-29 toll free in germany: 0800 639 7678 e-mail: info@omega.de united kingdom: one omega drive, river bend technology centre iso 9002 certified northbank, irlam, manchester m44 5bd united kingdom tel: +44 (0)161 777 6611 fax: +44 (0)161 777 6622 toll free in united kingdom: 0800-488-488 e-mail: sales@omega.co.uk omeganet ? online service i nternet e-mail omega.com info@omega.com it is the policy of omega engineering, inc.to comply with all worldwide safety and emc/emi regulations that apply. omega is constantly pursuing certification of its products to the european new approach directives. omega will add the ce mark to every appropriate device upon certification. the information contained in this document is believed to be correct, but omega accepts no liability for any errors it contains, and reserves the right to alter specifications without notice. warning: these products are not designed for use in, and should not be used for, human applications. ? www.datasheet.co.kr datasheet pdf - http://www..net/
3 ? os150 usb 2.2 series non-contact infrared sensors measure temperatures from 45c to 2000c and provide a linear 0 to 20 or 4 to 20 ma output. the signal is compatible with almost any indicator, controller, recorder, data logger etc., without the need for special interfacing or signal conditioning. they are especially suited to low-emissivity targets such as steel rollers and other metal surfaces, even at low temperatures. specification general temperature range lt: 45c * to 300c (os151-2usb-lt only) pt: 100 to 400oc (os151-2usb-pt only) mt: 250c to 1000c ht: 450c to 2000c output 4 to 20 ma, 0 to 20 ma (linear with temperature, adjustable via software) accuracy* 1% of reading or 2c whichever is greater repeatability* 0.5% of reading or 0.5c whichever is greater emissivity 0.1 to 1.0, adjustable via software response time 240 ms (90% response) field-of-view 15:1 (os151-2usb-lt or pt) 25:1 (os251-2usb-mt or ht) 75:1 (os751-2usb-mt or ht) ?7.5mm @ 500mm (os801-2usb-mt or ht) spectral response 2.0 to 2.4 m supply voltage 24 v dc (26 v dc max.) sensor voltage 11 v dc min. maximum loop impedance 900 ohms @ 24 v dc mechanical construction stainless steel dimensions 25 mm diameter x 106.5 mm output cable length 1 m (longer cable available to order) usb cable length 1 m weight with output cable 175 g environm ental environmental rating ip65 ambient temperature range 0c to 70c relative humidity 95% maximum non-condensing electromagnetic compatibility en61326-1:2006 industrial (analogue output only) en61326-1:2006 basic (usb) * object temperature > t min (see graph of minimum measurable temperature on page 9) 3.8 (98.0) 4.2 (106.5) 0.6 (15.0) 1.0 (25.0) m20 x 1mm 36.0 (1000.0) (standar d length) www.datasheet.co.kr datasheet pdf - http://www..net/
4 ? accessories a range of accessories to suit different applications and industrial environments is available. these may be ordered at any time and added on-site. the accessories consist of the following parts . fixed mounting bracket adjustable mounting bracket air purge collar laser sighting tool options the following options are available. options are factory installed and must be ordered with the os150 usb 2.2 sensor. air/water cooled housing certificate of calibration longer cable (30 m max.) optical ch art the optical chart below indicates the nominal target spot diameter at any given distance from the sensing head and assumes 90% energy. distance: sensor to object (inches) distance: sensor to object (mm) 15 60 135 0.6 2.4 5.3 0 59.1 118.1 0 1500 3000 spot dia. (inches) spot dia. (mm) spot dia. (inches) spot dia. (mm) distance: sensor to object (inches) distance: sensor to object (mm) 15 100 215 0.6 3.9 8.5 0 59.1 118.1 59.1 118.1 0 1500 3000 0 1500 3000 d:s 25:1 d:s 15:1 os251-2usb distance: sensor to object (inches) distance: sensor to object (mm) 15 20 55 0.6 0.8 2.2 0 spot dia. (inches) spot dia. (mm) d:s 75:1 os751-2usb os151-2usb spot dia. (inches) spot dia. (mm) distance: sensor to object (inches) distance: sensor to object (mm) 15 7.5 30 0.6 0.3 1.2 0 19.7 39.4 0 500 1000 os801-2usb www.datasheet.co.kr datasheet pdf - http://www..net/
5 ? ins tall ation the installation process consists of the following stages: preparation mechanical installation electrical installation please read the following sections thoroughly before proceeding with the installation. preparation ensure that the sensor is positioned so that it is focused on the target only. sensor best good incorrec t backgr ound t arget gr eater than spot size t arget equal to spot size t arget smaller than spot size distance an d spot size the size of the area (spot size) to be measured determines the distance between the sensor and the target. the spot size must not be larger than the target. the sensor should be mounted so that the measured spot size is smaller than the target. reflections the sensor must be installed in a location where energy from lamps, heaters and sunlight cannot be reflected from the target into the lens. the use of shields may help in this respect. for further information and assistance contact omega. ambient tem perature the sensor is designed to operate in ambient temperatures from 0c to 70c. for ambient temperatures above 70c, an air/water-cooled housing will be required. avoid thermal shock. allow 20 minutes for the unit to adjust to large changes in ambient temperature. a tmospheric quality smoke, fumes or dust can contaminate the lens and cause errors in temperature measurement. in these types of environment the air purge collar should be used to help keep the lens clean. www.datasheet.co.kr datasheet pdf - http://www..net/
6 ? electrical interference to minimise electromagnetic interference or noise, the sensor should be mounted away from motors, generators and such like. wiring check the distance between the sensor and the indicating/controlling device. if necessary, the os150 usb 2.2 sensor can be ordered with a longer output cable attached. mechanical ins tall ation all sensors come with a 1 m cable and a mounting nut. the sensor can be mounted on brackets or cut outs of your own design, or you can use the fixed and adjustable mounting bracket accessories which are shown below. 12.0 45.0 50.0 50.0 40.0 9.0 15.0 25.0 25.0 ?20.0 60 rotation 60 rotation 60 rotation 9.0 48.0 fixed bracket (fbl) adjustable bracket (abl) 2 x mounting holes m4 clearance 2 x mounting holes m4 clearance 9.0 24.0 24.0 26.0 34.0 47.0 58.5 81.0 1/8 bsp w ater/air connections air purge collar w ater/air cooling jacket air/w ater coole d housing the air/water cooled housing shown below allows the sensor to withstand high ambient temperatures. it is equipped with two 1/8 bsp fittings. water temperature should be 10c to 27c for efficient cooling. chilled water below 10c is not recommended. to avoid condensation, the air purge collar, supplied with the cooled housing, should be used. www.datasheet.co.kr datasheet pdf - http://www..net/
7 ? electrical ins tall ation the sensor to electronics cable is a 1 m ptfe cable. one end is attached, at the factory, to the sensor head. the other end has two pairs of wires and a shield (ground) wire. wiring the os150 usb 2.2 sensor can be used in three different ways as shown below. to use the analogue output, connect the os150 usb 2.2 sensor to the controller/indica - tor with the 24 v dc power supply using the following table and connection diagram as a guide. the maximum loop impedance is 900 ohms. note: the os150 usb 2.2 sensor must be grounded at only one point, either the cable shield or the sensor housing. wire no. wire colour function t ag 1 red power supply + pwr + 2 blue power supply - pwr C 3 yellow signal + op + 4 green signal C op C 5 bare shield ground alternatively, to use the usb output, connect the os150 usb 2.2 sensor to a pc using the cable provided. no external power supply is required when using the usb output. the os150 usb 2.2 sensor can also be used with both the analogue output and usb connected, provided that the negative terminal of the 24 v dc power supply being used is not grounded. note: the omegas oft software must be installed before connecting the sensor to a pc. 1/8 bsp air connection 27 58.5 26 34 47 air purge collar the air purge collar below is used to keep dust, fumes, moisture, and other contaminants away from the lens. it must be screwed in fully. air flows into the 1/8 bsp fitting and out of the front aperture. air flow should be no more than 5 to 15 litres/ min. clean or instrument air is recommended. www.datasheet.co.kr datasheet pdf - http://www..net/
8 ? o megasoft software system requirements ? omegasoft software is designed to run under windows. suitable versions are windows 2000, windows xp, windows vista and windows 7. ? the recommended minimum computer specification is: intel pentium processor vga display with 640x480 resolution usb 2.0 port i nstallation 1. insert the disk provided 2. installer should run automatically (if not, select the appropriate drive and double click on setup.exe) 3. follow the on-screen instructions note do not connect the os150 usb 2.2 sensor to the pc before the software is installed connecting the os150 usb 2.2 sensor to a pc 1. connect the circular connector on the usb cable provided to the os150 usb 2.2 sensor 2. connect the usb a connector on the usb cable provided to an available usb 2.0 port 3. double click on the omegasoft desktop icon c onfiguration ? setting temperature units temperature units can be set on the main temperature panel by pressing c or f. +- - + display/ contr oller red y ellow gr een blue power supply - + display/ contr oller pc pc n/c usb usb +- red y ellow gr een blue power supply www.datasheet.co.kr datasheet pdf - http://www..net/
9 ? ? setting output processing the temperature range for the analogue output, the averaging period and the peak/ valley hold processing can be set by using the main program menu to select: [setup] [output processing] the temperatures corresponding to the lower and upper limits of the analogue output can then be set as follows: model lower limit upper limit minimum span maximum span lt 45c 300c 100c 255c pt 100c 400c 100c 300c mt 250c 1000c 100c 750c ht 450c 2000c 100c 1550c the output type can be selected as either 0 ma to 20 ma or 4 ma to 20 ma. to minimise the the effects of temperature fluctuations, noise etc on the output signal, the averaging period can be set between 0 and 60 seconds. if required, hold processing can be applied by setting hold mode to peak hold or valley hold and setting a hold period between 0 and 1200 seconds. ? setting target emissivity to set an emissivity value for the os150 usb 2.2 sensor, use the main program menu to select: [setup] [emissivity] emissivity can then be set to a value between 0.1 and 1.0, or selected from a pre- set list of materials by selecting [data]. minimum measurable tempera ture (os151-2usb-lt only) ? setting reflected temperature compensation to enable and set reflected temperature compensation, use the main program menu to select: [setup] [reflection compensation] reflected temperature compensation can be enabled/disabled using [compensate for reflected temperature], and when enabled the temperature value can be set between 45 and 2000c, depending on the model selected. to store the changes in the sensors memory, select [file] [save sensor processing parameters]. graph showing the minimum measuarable object temperature (t min ), determined by surface emissivity () and sensor temperature (t s ). www.datasheet.co.kr datasheet pdf - http://www..net/
operation once the sensor is in position and the appropriate power, air, water, and cable con - nections are secure, the system is ready for continuous operation by completing the following simple steps: 1. turn on the power supply 2. turn on the instrument or pc 3. read / monitor the temperature im portant be aware of the following when using the sensor: ? if the sensor is exposed to significant changes in ambient temperature (hot to cold, or cold to hot), allow 20 minutes for the temperature to stabilise before taking or recording measurements. ? do not operate the sensor near large electromagnetic fields (e.g. around arc welders or induction heaters) or where energy from lamps, heaters and sunlight could be reflected into the lens. electromagnetic interference can cause measurement errors. ? wire must be connected only to the appropriate terminals. maintenance our customer service representatives are available for application assistance, calibra - tion, repair, and solutions to specific problems. contact our service department before returning any equipment. in many cases, problems can be solved over the telephone. if the sensor is not performing as it should, try to match the symptom below to the problem. if the table does not help, call omega for further advice. troubleshooting symptom p robable cause solution no output no power to sensor check power supply erroneous temperature incorrect wire connection check wire colour codes erroneous temperature faulty sensor cable verify cable continuity erroneous temperature field of view obstruction remove obstruction lens cleaning keep the lens clean at all times. any foreign matter on the lens would affect measure - ment accuracy. blow off loose particles (if not using the air purge accessory) with an air puffer. www.datasheet.co.kr datasheet pdf - http://www..net/
warranty/ disclaimer o mega engineering, inc. warrants this unit to be free of defects in materials an d workmanship for a period of 37 months from date of purchase. omega?s warranty adds an a dditional one (1) month g race period to the normal three (3) year product warranty to cover handling and shipping time. this e nsures that omega?s customers receive maximum coverage on each product. if the u nit malfunctions, it must be returned to the factory for evaluation. omega?s customer service department will issue an authorized return (ar) number immediately upon phone or written request. upon examination by omega, if the unit is found to be defective, it will be repaired or replaced at no charge. omega?s warranty does not apply to defects resulting from any action of the purchaser, i ncluding but n ot limited to mishandling, improper interfacing, operation outside of design limits, improper repair, or unauthorized modification. this warranty is void if the unit shows evidence of having been tampered with or shows evidence of having been damaged as a result of excessive corrosion; or current, heat, moisture or vibration; improper specification; misapplication; misuse or other operating conditions outside of omega?s control. components in which wear is not warranted, include but are not limited to contact points, fuses, and triacs. omega is pleased to offer suggestions on the use of its various products. however, omega neither assumes responsibility for any omissions or errors nor assumes liability f or any damages that result from t he use of its products in accordance with information provided by omega, either verbal or written. omega warrants only that the parts manufactured by the company will be as specified a nd f ree of d efects. omega m akes no other warranties or representations of any k ind w hatsoever, expressed or implied, except that of title, and a ll implied warranties including any warranty of merchantability and fitness for a particular purpose are hereby disclaimed. limitation of liability: the r emedies of purchaser set forth herein are exclusive, and the total liability of omega with respect to this order, whether b ased on contract, w arranty, negligence, indemnification, strict liability or otherwise, shall not exceed the purchase price of the component upon which liability is based. in no event shall omega be liable for consequential, incidental or special damages. conditions: equipment sold by omega is not intended to be used, nor shall it be used: (1) as a ?basic component? under 10 cfr 21 (nrc), used in or with any nuclear installation or activity; or (2) in medical applications or used on humans. should any product(s) be use d in or with any nuclear i nstallation or activity, m edical application, used on humans, or misused in any way, omega assumes no r esponsibility as set forth in our basic warranty / disclaimer language, and, additionally, purchaser will indemnify omega and hold omega harmless from any liability or damage whatsoever arising out of the use of the product(s) in such a manner. return requests/inquiries d irect all warranty and repair requests/inquiries to the omega customer service department. before returning any product(s) to omega, purchaser must obtain an authorized return (ar) number from omega?s customer service department (in order to avoid processing delays). t he assigned ar number should then be marked on the outside of the return package and on any correspondence. the purchaser is responsible for shipping charges, freight, insurance and proper packaging to prevent breakage in transit. for warranty returns, please have the following information available before contacting omega: 1. purchase order number under which the product was purchased, 2. model and serial number of the product under warranty, and 3. repair instructions and/or specific problems relative to the product. for non-warranty repairs, consult omega for current repair charges. have the following information available before contacting omega: 1. purchase order number to cover the cost of the repair, 2. model and serial number of the product, and 3. repair instructions and/or specific problems relative to the product. omega?s policy is to make running changes, not model changes, whenever an improvement is possible. this affords our customers the latest in technology and engineering. omega is a registered trademark of omega engineering, inc. ? copyright 2011 omega engineering, inc. all rights reserved. this document may not be copied, pho- tocopied, reproduced, translated, or reduced to any electronic medium or machine-readable form, in whole or in part, without the prior written consent of omega engineering, inc. www.datasheet.co.kr datasheet pdf - http://www..net/
where do i find ever y thing i need for pr ocess measurement and contro l? om ega?of course! shop online at omega.com sm temperature thermocouple, rtd & thermistor probes, connectors, panels & assemblies wire: thermocouple, rtd & thermistor calibrators & ice point references recorders, controllers & process monitors infrared pyrometers pressure, strain and force transducers & strain gages load cells & pressure gages displacement transducers instrumentation & accessories flow/level rotameters, gas mass flowmeters & flow computers air velocity indicators turbine/paddlewheel systems totalizers & batch controllers ph/conductivity ph electrodes, testers & accessories benchtop/laboratory meters controllers, calibrators, simulators & pumps industrial ph & conductivity equipmen t data acquisition data acquisition & engineering softwar e communications-based acquisition systems plug-in cards for apple, ibm & compatibles data logging system s recorders, printers & plotters heaters heating cable cartridge & strip heater s immersion & band heaters flexible heaters laboratory heaters e nvironmental monitoring and control metering & control instrumentatio n refractometers pumps & tubing air, soil & water monitors industrial water & wastewater treatmen t ph, conductivity & dissolved oxygen instruments m5069/1211 www.datasheet.co.kr datasheet pdf - http://www..net/


▲Up To Search▲   

 
Price & Availability of OS150-USB22

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X