Part Number Hot Search : 
SD112 CDP65C51 EMK13G2 060135MA P024F 256710 BU2500FV IRG7PH
Product Description
Full Text Search
 

To Download CPE-813 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  page date description: piezo audio transducer 1 of 5 11/12/2007 20050 sw 112 th ave. tualatin, oregon 97062 p h o n e phone 503.612.2300 f a x fax 503.612.2383 part number: CPE-813 specificatons operating voltage 30 vp-p max. current consumption 6 ma max. at 10 vp-p, sqaure wave, 4.0 khz sound pressure level 84 db min. at 10 cm/10 vp-p, sqaure wave, 4.0 khz electrostatic capacity 12,000 30% at 1 khz/1 v operating tempurature -30 ~ +85 c storage tempurature -40 ~ +95 c dimensions ?22.1 x h6.6 mm weight 2.5 g max. material abs ul-94 1/16? hb high heat (black) terminal pin type (au plating) rohs yes appearance drawing 10.0 0.8 0.2 (2 plcs) 22.1 5.3 6.6 3.0 tolerance: 0.5 units: mm
page date description: piezo audio transducer 2 of 5 11/12/2007 20050 sw 112 th ave. tualatin, oregon 97062 p h o n e phone 503.612.2300 f a x fax 503.612.2383 part number: CPE-813 frequency response curve measurement method s.p.l. measuring circuit input signal: 10 vp-p, 4.0 khz, square wave mic: rion s.p.l. meter uc30 or equivalent s.g.: hewlett packard 33120a function generator or equivalent
page date description: piezo audio transducer 3 of 5 11/12/2007 20050 sw 112 th ave. tualatin, oregon 97062 p h o n e phone 503.612.2300 f a x fax 503.612.2383 part number: CPE-813 environment test item test condition high temp. test after being placed in a chamber at +95c for 240 hours. low temp. test after being placed in a chamber at -40c for 240 hours. humidity test after being placed in a chamber at +40c and 905% relative humidity for 240 hours. temp. cycle test the part shall be subjected to 5 cycles. one cycle will consist of: evaluation standard the buzzer will be measured after being placed at +25c for 4 hours. the value of the oscillation frequency/current consumption should be 10% compared to the initial measurements. the spl should be within 10db compared to the initial measurements. +125 +25 +25 -40 0.5hr 0.5hr 0.25 0.5hr 0.5hr 0.5hr 0.25 3hours mechanical characteristics item test condition solderability lead terminals are immersed in rosin for 5 seconds and then immersed in solder bath of 270 5c for 3 1 seconds. soldering heat resistance lead terminals are immersed up to 1.5mm from buzzer?s body in solder bath of 300 5c for 3 0.5 seconds or 260 5c for 10 1 seconds. terminal mechanical strength for 10 seconds, the force of 9.8n (1.0kg) is applied to each terminal in axial direction. vibration the buzzer shall be measured after applying a vibration amplitude of 1.5 mm with 10 to 55 hz band of vibration frequency to each of the 3 perpendicular directions for 2 hours. drop test the part will be dropped from a height of 75 cm onto a 40 mm thick wooden board 3 times in 3 axes (x, y, z) for a total of 9 drops. evaluation standard 90% min. of the lead terminals will be wet with solder (except the edge of the terminal). no interference in operation. no damage or cutting off. the value of oscillation frequency/current consumption should be 10% of the initial measurements. the spl should be within 10db compared with the initial measurement.
page date description: piezo audio transducer 4 of 5 11/12/2007 20050 sw 112 th ave. tualatin, oregon 97062 p h o n e phone 503.612.2300 f a x fax 503.612.2383 part number: CPE-813 reliability test item test condition operating (life test) 1. continuous life test: the part will be subjected to 48 hours of continuous operation at +70c with rated voltage applied. 2. intermittent life test: a duty cycle of 1 minute on, 1 minutes off, a minimum of 5,000 times at room temp (+25 2c) with rated voltage applied. evaluation standard the buzzer will be measured after being placed at +25c for 4 hours. the value of the oscillation frequency/current consumption should be 10% compared to the initial measurements. the spl should be within 10db compared to the initial measurements. test conditions standard test condition a) tempurature: +5 ~ +35c b) humidity: 45 - 85% c) pressure: 860-1060 mbar judgement test condition a) tempurature: +25 2c b) humidity: 60 - 70% c) pressure: 860-1060 mbar
page date description: piezo audio transducer 5 of 5 11/12/2007 20050 sw 112 th ave. tualatin, oregon 97062 p h o n e phone 503.612.2300 f a x fax 503.612.2383 part number: CPE-813 packaging


▲Up To Search▲   

 
Price & Availability of CPE-813

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X