  specifications data sheet date fhc, fkc ... 3 fcx ?ax series differential pressure transmitter the fcx ax differential pressure transmitter accurately measures differential pressure, liquid level or gauge pressure and transmits a proportional 4 to 20ma signal. the trans- mitter utilizes a unique micromachined capacitance silicon sensor with state-of-the-art microprocessor technology to provide exceptional performance and functionality. EDSX6-100 mar. 15, 1999 1. high accuracy 0.07% accuracy for all calibrated spans is a standard feature for all dp models covering 0.1kpa{1m bar} draft range to 3000kpa{30 bar} high differential. fuji's micro- capacitance silicon sensor assures this accuracy for all elevated or suppressed calibration ranges without additional adjustment. 2. minimum environmental influence the "advanced floating cell" design which protects the pressure sensor against changes in temperature, static pressure, and overpressure substantially reduces total measurement error in actual field applications. 3. replaceable communication module fuji micro-electronics manufacturing technology offers replaceable communication module that makes fcx ax transmitter very unique in design. in case of change in communication protocol, all that needs to be done is just to replace the module and the transmitter gets upgraded to the new version. 4. fuji/hart bilingual communication module the communication module is "bilingual" to speak both fuji proprietary protocol and hart. any hart compatible devices can communicate with fcx ax series trans- mitters. 5. application flexibility various options that render the fcx ax suitable for almost any process applications include. analog indicator at either the electronics side or terminal side full range of hazardous area approvals built-in rfi filter and lightning arrester ? -digits lcd meter stainless steel electronics housing wide selection of materials 6. programmable output linearization function in addition to linear and square root, output signal can be freely programmable. (up to 14 compensated points at approximation.) (available for amplifier unit from version 24 and fxw(hhc) version 5.3.) 7. burnout current flexibility (under scale: 3.2 to 3.8ma, over scale: 20.8 to 21.6ma) burnout signal level is adjustable using model fxw hand held communicator (hhc) to comply with namur ne43. (available for amplifier unit from version 24 and fxw(hhc) version 5.3.) f c 11 f c 22 f c 23 f c 25 f c 26 f c 33 f c 35 f c 36 f c 38 f c 43 f c 44 f c 45 f c 46 f c 48 ?.1 to + 3.2 {? to + 32} ?.1 to + 10 {? to + 100 } ?.1 to + 10 {? to + 100 } ?.1 to + 10 {? to + 100 } ?.1 to + 10 {? to + 100 } ?.1 to + 16 {? to + 160 } ?.1 to + 16 {? to + 160 } ?.1 to + 16 {? to + 160 } ?.1 to + 16 {? to + 160 } ?.1 to + 42 {? to + 420 } ?.1 to + 42 {? to + 420 } ?.1 to + 42 {? to + 420 } ?.1 to + 42 {? to + 420 } ?.1 to + 42 {? to + 420 } +/ 1 { +/ 10 } +/ 6 { +/ 60 } +/ 32 { +/ 320 } +/ 130 { +/ 1300 } +/ 500 { +/ 5000 } +/ 32 { +/ 320 } +/ 130 { +/ 1300 } +/ 500 { +/ 5000 } +/ 3000 { +/ 30000 } +/ 32 { +/ 320 } +/ 64 { +/ 640 } +/ 130 { +/ 1300 } +/ 500 { +/ 5000 } +/ 3000 { +/ 30000 } 0.1 {1} 0.6 {6} 3.2 {32} 13 { 130 } 50 { 500} 3.2 { 32} 13 { 130 } 50 { 500 } 300 { 3000 } 3.2 {32 } 6.4 {64} 13 { 130 } 50 { 500 } 300 { 3000 } 0.1 {1} 0.1 {1} 0.32 { 3.2 } 1.3 {13} 5 {50} 0.32 { 3.2 } 1.3 {13} 5 {50} 30 { 300 } 0.32 { 3.2 } 0.64 { 6.4 } 1.3 {13} 5 {50} 30 { 300 } 1 {10} 6 {60} 32 { 320 } 130 { 1300 } 500 { 5000 } 32 { 320 } 130 { 1300 } 500 { 5000 } 3000 { 30000 } 32 { 320 } 64 { 640 } 130 { 1300 } 500 { 5000 } 3000 { 30000 } max. fhc/fkc min. fhc fkc type range limit [kpa] {m bar} static pressure [mpa] {bar} span limit [kpa] {m bar} 8. dry calibration without reference pressure thanks to the best combination of unique construction of mechanical parts (sensor unit) and high performance electronics circuit (electronics unit), reliability of dry calibration without reference pressure is at equal level as wet calibration. functional specifications type: model fhc: 4 to 20ma model fkc: 4 to 20ma with digital signal service: liquid, gas, or vapour static pressure, span, and range limit: remark : to minimize environmental influence, span should be greater than 1/40 of the max. span in most applications. features 1 2
fhc, fkc ... 3 2 lower limit of static pressure (vacuum limit) ; silicone fill sensor: see fig. 1 f c 38 and f c 48: ?.5kgf/cm 2 fluorinated fill sensor: 66kpa abs (500mmhg abs) at temperature below 80 c the maximum span of each sensor can be converted to different units using below factors. 1mpa= 10 3 kpa=10bar=10.19716kgf/cm 2 = 145.0377psi 1kpa=10mbar=101.9716mmh 2 o=4.01463inh 2 o over range limit: to maximum static pressure limit output signal: model fhc: 4 to 20ma dc 2-wire, linear signal model fkc: 4 to 20ma dc (linear or square root) with digital signal superimposed on the 4 to 20ma signal power supply: transmitter operates on 10.5v to 45v dc at transmitter terminals. 10.5v to 32v dc for the units with optional arrester. load limitations: see figure below zero elevation/suppression: ?00% to +100% of url normal/reverse action: model fhc: selectable by moving a jumper pin located on the electronics unit. model fkc: selectable from hhc indication: analog indicator or 4 -digit lcd meter, as specified. burnout direction: if self-diagnostic detect transmitter fail- ure, the analog signal will be driven to ei- ther ?utput hold? ?utput overscale or ?utput underscale?modes. model fhc: unless otherwise specified in the order, the transmitter will be shipped in ?utput hold?mode. (output signal just before failure happens is maintained.) model fkc: selectable from hhc ?utput hold? output signal is hold as the value just be- fore failure happens. ?utput overscale? approx. 21.6ma (adjustable within the range 20.8ma to 21.6ma from hhc) ?utput underscale? approx. 3.8ma (adjustable within the range 3.2ma to 3.8ma from hhc) 0 3.8 3.2 4 20 20.8 21.6 over scale burnout probable over range probable under range normal operating range under scale burnout loop-check output: model fhc: transmitter can output constant signal of 4ma, 12ma, or 20ma if mode switch is set to the loop check mode. model fkc: transmitter can be configured to provide constant signal 3.8ma through 21.6ma by hhc. temperature limit: ambient: 40 to +85 c (?0 to +80 c for lcd indicator) ( 40 to +60 c for arrester option) (?0 to +60 c for fluorinated oil filled transmitters) 15 to +85 c for 5th digit code ??and 6 digit code ?? for explosionproof units (flameproof or intrinsic safety), ambient temperature must be within the limits specified in each standard. process: 40 to +120 c for silicone fill sensor ?0 to +80 c for fluorinated oil fill sen- sor storage: 40 to +90 c humidity limit: 0 to 100% rh note: for communication with hhc (model: fxw), min. of 250 ? required. hazardous locations: (approval pending) baseefa ex ds iic t5, t6 eex ia iic t4, t5 ex n ii t5 factory class i ii iii class i ii iii class i ii iii mutual div. 1 div. 1 div. 2 groups b thru. g groups a thru. f groups a thru. g csa class i ii iii class i ii iii class i ii iii div. 1 div. 1 div. 2 groups c thru. g groups a thru. g groups a thru. g riis ex ds iib+h 2 t4 saa ex d ii c t5, t6 ex ia ii c t5, t6 ex n ii c t5, t6 ip 66/67 ip 66/67 ip 66/67 type n nonincendive authorities flameproof intrinsic safety zero/span adjustment : model fhc: zero is adjustable from the external ad- justment screw. the adjustment screw can also function to adjust span when mode switch (lo- cated on the electronics unit) is in the span mode. inhibit mode to disable the ad- justment screw is also available. model fkc: zero and span are adjustable from the hhc. zero is also adjustable externally from the adjustment screw. damping: adjustable electrical damping. model fhc: the ti me constant is adjustable to 0, 0.3, 1.2, 4.8, or 19.2 seconds. model fkc: the time constant is adjustable between 0 to 38.4 seconds. (4 steps) 2000 [ ? ] 1500 1000 load resistance 500 250 1533 ? 600 ? operating area 24v 45v 10 16.1 50 [ v ] 10.5v power voltage 1 2
3 double the effects for material code (7th digit in code sym- bols) ?? ?? ?? ?? ??and ?? () () range code (6th digit in code symbols) ??1kpa {10mbar} max. span ??6kpa {60mbar} max. span ??32kpa {320mbar} max. span ??64kpa {640mbar} max. span ??130kpa {1300mbar} max. span ??500kpa {5000mbar} max. span ??3000kpa {30000mbar} max. span url span 0.1+0.025 %/28 c 0.125+0.025 %/28 c url span url span 0.125+0.1 %/28 c () 0.15+0.1 %/28 c () url span total effect zero shift static pressure code (5th digit in code symbols) static pressure effect: ??/1kpa {10m bar} sensor ??/6kpa {60 m bar} sensor ? ? ? double the zero shift for material code (7th digit in code symbols) ?? ?? ?? ?? ??and ?? overrange effect: static pressure code (5th digit in code symbols) ??/ 1kpa {10m bar} sensor ??/ 6kpa {60m bar} sensor ? ? ? 0.3% / 1mpa {10bar } 0.3% / 3.2mpa {32bar } 0.1% /10mpa {100bar } 0.1% /16mpa {160bar } 0.17% /42mpa {420 bar} double the effects for material code (7th digit in code sym- bols) ?? ?? ?? ?? ??and ?? note: (*1) in case of 6th code ?? supply voltage effect: less than 0.05% of calibrated span per 10v rfi effect: less than 0.2% of url for the frequen- cies of 20 to 1000mhz and field strength 30 v/m when electronics covers on. (classification: 2-abc: 0.2% span per sama pmc 33.1) step response: (without electrical damping) span shift (% of calibrated span) zero shift (% of url) 0.05%/10mpa{100bar} ?.2%/10mpa{100bar} 0.1% / 1mpa{10bar} ?.2% /3.2mpa{32bar} 0.1% / 3.2mpa{32bar} ?.2% /3.2mpa{32bar} zero shift (% of url) tag no. model no. serial no. engineering unit range limit measuring range damping output mode burnout direction adjustment output adjust data self diagnoses printer external switch lock transmitter display(*) linearise (**) rerange (**) vv vv v vv v vv vv vv vv vv ? v v vv vv vv vv items display set notes: (*) hhc's version must be more than 5.0 (or fxw 1 2 ), to use this function. (**) hhc's version must be more than 5.3, and amplifier unit version 24. 0.1 url span 0.02+0.05 % of span ( ) ? ? ? (*1) communication: (model fkc only) with hhc (model fxw, consult data sheet no. eds8-47), following informa- tion can be remotely displayed or recon- figured. programmable output linearization function: in smart version, output signal can be characterized with ?4 points linear ap- proximation function?from hhc. performance specifications for linear output accuracy rating: (including linearity, hysteresis, and re- peatability) max span above 32kpa model: for spans greater than 1/10 of url: 0.07% of span for spans below 1/10 of url (model fkc only): max span 1kpa, 6kpa model: for spans greater than 1/10 of url: 0.1% of span for spans below 1/10 of url (model fkc only): linearity: 0.05% of calibrated span stability: 0.1% of upper range limit (url) for 24 months temperature effect: effects per 55 c change between the lim- its of ?40 c and +85 c 0.1 url span 0.05+0.05 % of span () approx. 0.3 s range code time constant dead time 1.25 s 0.85 s 0.45 s 0.2 s ? ? ? ??through ? mounting position effect: zero shift, less than 0.12kpa {1.2m bar} for a 10 tilt in any plane. no effect on span. this error can be corrected by adjusting zero. (double the effect for fluorinated fill sen- sors) dielectric strength: 500v ac, 50/60hz 1 min., between circuit and earth. insulation resistance: more than 100m ? at 500v dc. turn-on time: 4 sec. internal resistance for external field indicator: 12 ? or less
fhc, fkc ... 3 4 process-wetted parts material: v h m t b l u 316 stainless steel hastelloy-c lining monel lining tantalum lining hastelloy-c lining monel lining tantalum lining 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel hastelloy-c monel tantalum 316l stainless steel hastelloy-c monel tantalum hastelloy-c monel tantalum 316 stainless steel(*1) 316 stainless steel(*1) 316 stainless steel(*1) 316 stainless steel(*1) hastelloy-c lining monel lining tantalum lining material code (7th digit in code symbols) process cover diaphragm wetted sensor body vent/drain notes: * (1) scs14 per jis g 5121 remark: sensor o-rings: viton and teflon selectable. availability of above material design depends on ranges and static pressure. refer to ?ode sym- bols? non-wetted parts material: electronics housing: low copper die-cast aluminum alloy (standard), finished with polyester coating, or 316 stainless steel (scs14 per jis g5124), as speci- fied. bolts and nuts: cr-mo alloy (standard), 304 stainless steel (for static pressure code ?? ?? and ??only), or 630 stainless steel (for static pressure code ??and ??only). static pressure rat- ing for code ??with 304 stainless steel bolts is degraded to 10mpa. fill fluid: silicone oil (standard) or fluori- nated oil (daifloil) mounting bracket: carbon steel with ep- oxy coating or 304 stainless steel, as specified environmental protection: iec ip67 and nema 4x mounting: on 60.5mm(jis 50a) pipe using mounting bracket, direct wall mounting, or direct process mounting. mass{weight}: transmitter approximately 4.4kg without options. add; 0.5kg for mounting bracket 0.8kg for indicator option 4.5kg for stainless steel housing option physical specifications electrical connections: g1/2, 1/2-14 npt, pg13.5, or m20 1.5 conduit, as specified. process connections: 1/4-18 npt or rc1/4 on 54mm centers, as specified. meets din 19213. () performance specifications for square root output (model fkc only) accuracy rating: temperature effect: effect per 55 c change between the lim- its of 40 c and +85 c range code shift at 20% output point ??and ? ??through ? 0.3+0.25 %/28 c 0.25+0.0625 %/28 c low flow cut-off: customer configurable for any point be- tween 7 to 20% of output url span url span () max span 1kpa, 6kpa model: 50 to 100% 20 to 50% 10 to 20% 0.07 % 0.175 % 0.35 % span output (0.02+0.05 0.1 url/span)% 2.5 (0.02+0.05 0.1 url/span)% 5 (0.02+0.05 0.1 url/span)% below 0.1 url over 0.1 url output accuracy 50 to 100% 20 to 50% 10 to 20% 0.1 % 0.25% 0.5 %
5 degreasing: process-wetted parts are cleaned, but the fill fluid is standard silicone oil. not for use on oxygen or chlorine measurement. nace specification: metallic materials for all pressure bound- ary parts comply with nace mr-01-75. astm b7m or l7m bolts and 2hm nuts (class ii) are available. static pressure rating for code ??(16 mpa) is degraded to 10mpa. vacuum service: special silicone oil and filling procedure are applied. see below figure. fig. 1 relation between process temperature and operating pressure customer tag: a stainless steel tag with customer tag data is wired to the transmitter. coating of cell: cell's surface is finished with epoxy/poly- urethane double coating. specify if envi- ronment is extremely corrosive. oval flanges: (model ffp, refer to data sheet no. eds6-10) converts process connection to 1/2-14 npt or to rc1/2; in carbon steel or in 316 stainless steel. equalizing valves: (model ffn, refer to data sheet no. eds6-10) available in cs or in 316 stainless steel and in pressure rating 16mpa or 42mpa. hand-held communicator: (model fxw, refer to data sheet no. eds 8-47) communication module: (standard for model fkc) by adding communication module, re- mote setting functions becomes available for model fhc. remark: when the communication module is con- nected, the operation mode of external zero/span adjustable screw is limited to zero adjustment only. accessories ?0 60 ?5 85 120 none-operating area 2.7 {27} 4 {40} 20 operating pressure process temperature[ c ] {200} 101 {1010} [kpa abs] {mbar abs} silicone oil (code:y,g,n) silicone oil (code:r) operating area 1 2 optional features indicator: a plug-in analog indicator (1.5% accuracy) can be housed in the electronics compart- ment or in the terminal box of the housing. an optional 4 digits lcd meter is also available. arrester: a built-in arrester protects the electronics from lightning surges. lightning surge immunity: 4kv (1.2 50 s) oxygen service: special cleaning procedures are followed throughout the process to maintain all pro- cess wetted parts oil-free. the fill fluid is fluorinated oil. chlorine service: the fill fluid is fluorinated oil.
fhc, fkc ... 3 6 code symbols 12345678 910111213 1415 description type 4 to 20ma, output type 4 to 20ma with digital signal, output type connections process connection rc1/4 1/4-18npt 1/4-18npt 1/4-18npt 1/4-18npt oval flange screw 7/16-20unf 7/16-20unf m10 (or m12)(*!) m10 (or m12)(*!) 7/16-20unf conduit connection g 1/2 1/2-14npt pg 13.5 m20 1.5 pg 13.5 span and materials process cover 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel hast. c lining monel lining tantalum lining hast. c lining monel lining tantalum lining hast. c lining monel lining wetted cell body 316 stainless steel hast. c lining 316 stainless steel hast. c lining 316 stainless steel hast. c lining monel lining tantalum lining 316 stainless steel hast. c lining monel lining tantalum lining 316 stainless steel hast. c lining monel lining tantalum lining 316 stainless steel 316 stainless steel hast. c lining monel lining 316 stainless steel hast. c lining monel lining 316 stainless steel hast. c lining monel lining 316 stainless steel hast. c lining monel lining tantalum lining hast. c lining monel lining tantalum lining hast. c lining monel lining diaphragm 316l stainless steel hast. c 316l stainless steel hast. c 316l stainless steel hast. c monel tantalum 316l stainless steel hast. c monel tantalum 316l stainless steel hast. c monel tantalum 316l stainless steel 316l stainless steel hast. c monel 316l stainless steel hast. c monel 316l stainless steel hast. c monel 316l stainless steel hast. c monel tantalum hast. c monel tantalum hast. c monel tantalum 11v 11h 22v 22h 33v 33h 33m 33t 35v 35h 35m 35t 36v 36h 36m 36t 38v 43v 43h 43m 45v 45h 45m 46v 46h 46m 48v 23b 23l 23u 25b 25l 25u 26b 26l 26u 3 fhc fkc s t v w x notes: * (1) the thread is m12, if 42mpa {420bar} static pressure is specified. (2) 100: 1 turn down is possible for model fkc, but should be used at the span greater than 1/40 of the maximum span for better performance. static pressure [mpa] {bar} ?.1 to +3.2 {? to +32} ?.1 to +10 {? to 100} ?.1 to +16 {? to +160} ?.1 to +42 {? to +420} ?.1 to +10 {? to+100} span limit (* 2 ) fhc/fkc [kpa] (m bar) 0.1/0.1?/1 {1/1?0/10} 0.6/0.1?/6 {6/1?0/60} 3.2/0.32?2/32 {32/3.2?20/320} 13/1.3?30/130 {130/13?300/1300} 50/5?00/500 {500/50?000/5000} 300/30?000/3000 {3000/300?0000/30000} 3.2/0.32?2/32 {32/3.2?20/320} 13/1.3?30/130 {130/13?300/1300} 50/5?00/500 {500/50?000/5000} 300/30?000/3000 {3000/300?0000/30000} 3.2/0.32?2/32 {32/3.2?20/320} 13/1.3?30/130 {130/13?300/1300} 50/5?00/500 {500/50?000/5000}
7 description 3 fkc 3 fhc 12345678 910111213 1415 indicator and arrester indicator arrester none available for 4th digit code ?? none analog, 0 to 100% linear scale none analog, 0 to 100% sq. root scale none analog, custom scale none analog, double scale none (* 6 ) none yes analog, 0 to 100% linear scale yes analog, 0 to 100% sq. root scale yes analog, custom scale yes analog, double scale yes (* 6 ) digital, 0 to 100% none digital, custom scale none (model fkc only) (* 7 ) digital 0 to 100% square root none digital, 0 to 100% yes digital, custom scale yes (model fkc only) (* 7 ) digital 0 to 100% square root yes approvals for hazardous locations (approval pending) none (for ordinary locations) jis, flameproof (conduit seal) (available for 4th digit code ?? jis, flameproof (cable gland seal) (available for 4th digit code ?? fm, flameproof (or explosionproof) (available for 4th digit code ?? csa, flameproof (or explosionproof) (available for 4th digit code ?? baseefa, flameproof (conduit seal) baseefa, flameproof (cable gland seal) (conduit connection g 1/2 only) fm, intrinsic safety and nonincendive csa, intrinsic safety and nonincendive cenelec, intrinsic safety cenelec, intrinsic safety and baseefa, type n saa flameproof (conduit seal)(available for 4th digit cord (?,t,w) saa intrinsic safety (available for 4th digit cord (?,t,w) saa type? (non-sparking)(available for 4th digit cord (?,t,w) side vent/ drain and mounting bracket side vent/drain mounting bracket none none none yes, carbon steel none yes, stainless steel yes none yes yes, carbon steel yes yes, stainless steel stainless steel parts stainless steel tag plate stainless steel elec, housing coating of cell none none none yes none none none yes none yes yes none none none yes yes none yes none yes yes yes yes yes special applications and fill fluid treatment fill fluid none (standard) silicone oil none (standard) fluorinated oil degreasing silicone oil oxygen service fluorinated oil (7th digit code "w", "v" only) chlorine service fluorinated oil (7th digit code "h", "t", "b", "u") nace specification silicone oil (not available for 7th digit code "t", "u" and 15th digit code "a", "b") vacuum service silicone oil for vacuum use sensor o-ring viton teflon bolt/nut cr-mo alloy hexagon socket head cap screw/carbon steel nut cr-mo alloy hexagon bolt/nut nace bolt/nut (astm a193 b7m/a194 2hm) nace bolt/nut (astm a320 l7m/a194 2hm) 304 stainless steel/304 stainless steel 630 stainless steel/304 stainless steel } } } } notes: (* 3 ) static pressure should be ?.1 to +10mpa{? to +100bar}. (* 4 ) available for 5th digit code "1", "2", "3". in case of stainless steel bolt with 5th digit code "3", static pressure should be ?.1 to +10mpa {? to + 100bar}. (* 5 ) available for 5th digit code "3", "4". (* 6 ) the scale is selectable "jis and si unit" or "linear and sq. root" or "linear and sq. root by 10". (* 7 ) incase of fkc, specified the output mode linear or sq. root. unless specified, the output mode is linear. in case of 9th digit code "p", "s" with fkc, specified the output indication. unless specified, the indication is output mode. (* 8 ) in case of tropical use, select a stainless bolts and nuts. a b c d e m n h j k p r t q a b c d e f y b c e m n p q y w g a d n r a b c d j e f g h k l p m q s n a b c d e f a b specify "a", "b", or "c" for the 7th digit code "b", "l", or "u" } (* 3 ) (* 4 ) (* 5 ) (* 8 )
fhc, fkc ... 3 8 outline diagram (unit:mm) 104 ?0 43.5 126.5 120 110 50 88 242 38 58 70 37 51 270 71 ?0 (27) l.p. 4-m8 12 h.p. 104 54 41.3 70 17 g 1/2 ?3 e d ?5 f ? ?8.5 h 2.5 8 press. conn. rc1/4 1/4-18npt conduit conn. d g1/2 pg13.5 1/2?4npt 4.5 16 16 17 e f 8 8 5 5 s t x v m20x1.5 w pg13.5 4.5 8 h 1/4-18npt 1/4-18npt 1/4-18npt 7/16?0unf screw depth 13 7/16?0unf screw depth 13 m10 or m12 screw depth 13 m10 or m12 screw depth 13 7/16?0unf screw depth 13 m4 m4 m4 m4 4th digit code ovale frange screw earth terminal no.8?2unc u - bolt m8 vent/drain plug 4 holes 9 dia. see table 1 see table 1 side vent (option) up down detail ? detail ? (conduit conn.) (press conn.) detail ? cable gland (option) see note ? conduit conn. ? conduit conn. fastener (in case of 10th digit code ?,c,m,n? zero/span adj. screw with field ind. (option) oval flange screw see table1 1 mtg. pipe jis 50a (2") ? press. conn. vent/drain plug (when the vent/drain plug attatched on the upper side of the detector) in case of 4th digit code ?,v,w,x + connection diagram + ck+ ck earth terminal (both side ) see table1 note1) : cable gand is supplied in case of flamproof packing type. ?1 cable is suitable. f h k c s t v w x w v h m t 3
9 f h k c s t v w x b l u 3 2 104 80 43.5 120 245 40 58 38 70 41.3 110 50 88 17 g 1/2 13 e f h 15 +0.2 +0.1 16 12 1 4 4 16 1/4-18npt 10 2 0 -0.1 273 70 104 h.p. l.p. 54 4-m8 12 51 71 80 (27) ef t 17 8 m4 m4 x 1/2 -14npt 16 5 7/16?0unf screw depth 13 7/16?0unf screw depth 13 m10 screw depth 13 m10 screw depth 13 7/16?0unf screw depth 13 h s v w g1/2 pg13.5 m20 1.5 pg13.5 8 16 8 4.5 5 4.5 no. 8-32unc m4 m4 table 1 4th digit code conduit conn. oval flange screw earth terminal note) : cable gland is supplied in case of flameproof packing type. 11 cable is suitable. detail ? (press. conn.? 4th digit code ? in case of 4th digit code ?,v,w,x fastener (in case of 10th digit code ?,c,m,n? zero/span adj. screw 4 holes 9 dia. up down mtg.pipe jis 50a (2") u - bolt m8 detail ? (conduit conn.) detail ? 4th digit code ?,v,w,x detail ? cable gland (option) note see ? conduit conn. ? conduit conn. vent/drain plug with field ind (option) ??or ?? press conn. oval fgange screw see table 1 earth terminal (both side) see table 1 see table 1 + ck+ ck + connection diagram the product conforms to the requirements of the electromagnetic compatibility directive 89/336/eec as detailed within the technical construction file number tn510412. the applicable standards used to demonstrate compliance are :- emi (emission) en50081-1 : 1992 "lvd - the transmitter is not covered by the requirements of the lvd standard." ems (immunity) en50082-1 : 1992 test item frequency range basic standard applicable electro- magnetic radiation disturbance 30-1000mhz en55022 class b test item no. test specification basic standard performance criteria 1 2 3 b a b electrostatic discharge fast transients common mode 0.5kv, 5/50 (tr/th) ns 5khz rep. radio-frequency electromagnetic field. 8kv (air) 27-500mhz 3v/m (unmodulated) iec 801-2:1984 iec 801-3:1984 iec 801-4:1988
fhc, fkc ... 3 information in this catalog is subject to change without notice. printed in japan head office 11-2 osaki 1-chome, shinagawa-ku, tokyo, 141-0032 japan phone: 81-3-5435-7111 http://www.fujielectric.co.jp/eng/sg/keisoku/welcome.htm sales div. international sales dept. no.1, fuji-machi, hino-city, tokyo, 191-8502 japan phone: 81-42-585-6201, 6202 fax: 81-42-585-6187, 6189


▲Up To Search▲   

 
Price & Availability of EDSX6-100

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X