Part Number Hot Search : 
SY88903V D22012B 10700 LPT25 TDA98 10002 0T3354 30301
Product Description
Full Text Search
 

To Download 95111 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  ausgabedatum26.03.2001 subject to reasonable modifications due to technical advances. copyright pepperl+fuchs, printed in germany pepperl+fuchs group ? tel.: germany (06 21) 7 76-0  usa (330) 4 25 35 55  singapore 7 79 90 91  internet http://www.pepperl- fuchs.com 1 technische daten technical data features electrical connection dimensions general specifications sensing range 100 ... 2000 mm standard target plate 100 mm x 100 mm unusable area 100 mm transducer frequency approx. 175 khz response delay minimum (em; none): 50 ms (2 measuring cycles) factory setting (em, mxn, 5, 2): 150 ms (6 measuring cycles) dynamic (em, dyn): 75 ms (3 measuring cycles) standard conformity en 60947-5-2 indicating/operating means led green continuous: object in the measuring window flashing: object outside the measuring window led red error (e. g. interference level too high) electrical specifications rated operational voltage u e 10 ... 30 v dc without current output function 15 ... 30 v dc with current output function ripple 10 % ss power consumption p 0 2 w (all relays pulled-in, current output 20 ma) no-load power consumption 0.7 w output output type 2 relay outputs, 1 analogue output 4 ... 20 ma contact loading 60 v dc / 1 a (max. 24 w dc), ohmic lifetime electrical: 3 x 10 5 operating cycles at ohm. load (1 a / 24 v dc) mechanical: 10 7 operating cycles range hysteresis h 0 ... 15 % parameterisable repeat accuracy 0.1 % resolution 0.5 mm load impedance current output: 500 ohm deviation of the characteristic curve < 0.2 % of final value temperature influence 2 %, internal temperature compensation interface interface type rs 232, 9600 bit/s, no parity, 8 data bits, 1 stop bit ambient conditions ambient temperature -25 ... +70 c (248 ... 343 k) storage temperature -40 ... +85 c mechanical specifications protection degree ip65 according to en 60529 connection type 8-pin round connector, lumberg type rsf 8 material housing pbt mass 290 g  current output  2 relays  serial interfaces  temperature compensation  watchdog  reverse polarity protection  parameterisable standard symbol/connection: u +u b -u b rxd txd 1 2 4 6 7 3 5 led window bore holes for thread m4 (the delivery includes 4 pcs.) transducer 5 mm countersunk 117 100 5.5 5.5 41 52 22 134 100 30 m4 13 uc2000-f43-2kir2-v17 uc2000-f43-2kir2-v17 single head system
2 subject to reasonable modifications due to technical advances. copyright pepperl+fuchs, printed in germany pepperl+fuchs group  tel.: germany (06 21) 7 76-0  usa (330) 4 25 35 55  singapore 7 79 90 91  internet http://www.pepperl-fuchs.com hinweise note ausgabedatum26.03.2001 model number characteristic curves/ additional information uc2000-f43-2kir2-v17 1.5 1.8 2.1 2.4 2.7 3.0 3.3 0.0 0.3 0.6 0.9 1.2 characteristic response curves distance [m] angle [degrees] curve 1: flat plate 100 mm x 100 mm curve 2: round bar, ? 25 mm 1 20 10 -0 -10 -20 90 80 70 60 50 40 30 2 thanks to its extensive command set, the sensor can be configured to suit the ap- plication via the rs 232 interface. rs 232 command set (overview) command meaning parameter access vs0 v elocity of s ound at 0 c velocity of sound at 0 centigrade vs0 in [cm/s] {10000 ... 60000) read and set vs v elocity of s ound velocity of sound vs in [cm/s] read to t emperature o ffset to in [0.1k] read and set tem tem perature tem in [0.1k] read and adapt to to ref ref erence measurement ref distance in [mm] {100 ... 4000} adaptation of vs0 sd1 s witching d istance 1 switching point, relay 1 sd1 in [mm] {100 ... 4000} read and set sd2 s witching d istance 2 switching point, relay 2 sd1 in [mm] {100 ... 4000} read and set sh1 s witching h ysteresis 1 hysteresis, relay 1 in [%] {0 ... 15} read and set sh2 s witching h ysteresis 2 hysteresis, relay 2 in [%] {0 ... 15} read and set nde n ear d istance of e valua- tion near measuring window limit in [mm] {100 ... 4000} read and set fde f ar d istance of e valuation far measuring window limit in [mm]{100 ... 4000} read and set br b lind r ange unusable area in [mm] {100 ... 4000} read and set cbt c onstant b urst t ime burst length in [s] {0,1, 2, 3} read and set cct c onstant c ycle t ime time in [ms] {0 ... 1000} read and set fto f ilter t ime o ut number of measurements without echo to be filtered {0 ... 255} read and set em e valuation m ethod evaluation method { 0 = none; pt1[,f,p,c]; mxn[,m,n]; dyn[,p] } read and set con con servative filter counter threshold as number {0 ... 255} read and set om o utput m ode om coded [normally-open no = 0, nor- mally-closed nc = 1] read and set fsf f ail s afe f unction failure function type e.g. fsf,11,35 {0,1,2}, [fault current in 0.1 ma] read and set md m aster d evice function as master {0 = none},ad,rd,rt,ss,adb,rdb,rtb } read and set ma m ain a pplication determines whether the green led orients itself according to nde, fde or sd1 and sd2 read and set nef n o e cho f ailure sensor behavior when no echo is present {0,1} read and set ad a bsolute d istance distance in [mm] read rd r elative d istance relative distance as number {0 ... 4095} read rt r un t ime echo run time in machine cycles [1 machine cycle = 1.085 s] read ss1 s witching s tate 1 ss1 binary [0: inactive, 1 active] (independ- ent of om) read ss2 s witching s tate 2 ss2 binary [0: inactive, 1 active] (independ- ent of om) read adb a bsolute d istance b inary distance in [mm] not as ascii read rdb r elative d istance b inary relative distance as number {0 ... 4095} not as ascii read rtb r un t ime b inary echo run time in machine cycles [1 machine cycle = 1.085 s] not as ascii read er e cho r eceived echo detected: no, yes [0/1] read ver ver sion version str ing: xxxx read id id entification id string: p&f uc2000-f43-2kir2-v17... read dat dat e date string: e.g. date: e.g. 04/12/99 time: 11:14:35 read st st atus status as hexadecimal string read rst r e s e t performs a reset command def def ault settings restores defaults command suc s tore u ser c onfiguration stores all settings command ruc r ecall u ser c onfiguration restores stored settings command basic setting om: relay 1: no relay 2: no sd1/sd2: switch point relay 1 = 100 mm switch point relay 2 = 2000 mm nde/fde: analogue output: 4 ma ? 100 mm 20 ma ? 2000 mm fsf: error ? relay 1 and 2: latest state ? analogue output: i out = 3,9 ma nef: no echo ? error message ma,s: switching mode


▲Up To Search▲   

 
Price & Availability of 95111

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X