  for reference only product specifications hsu ? 07 series humidity sensor unit hokuriku electric industry co.,ltd.
contents 1. application 2. type designation 3. outline dimensions 4. absolute maximum rating 5. recommended line voltage range 6. measuring circuit 7. electrical characteristic 8. reliability tests 9. notes for use 10. temperature humidity characteristics (for reference) hokuriku electric industry co.,ltd.
1. application this specification shall be applied to the relative humidity sensor [HSU-07]. 2. type designation hsu 07 a 2 design no. mark of contour mark substrate contour mounted hole 18 30 mm 4mm 1 18 21 mm ---- number of output characteristic mark humidity detection range 0 6 10 ~ 90%rh 0 7 20 ~ 90%rh humidity sensor unit type name 3. outline dimensions mounting of a part is prohibited on the hatched area. connector pin arrangement parts component table no. name mark parts no. name material and specification power source terminal cc humidity sensor his-06 output terminal out printed circuitboard paper phenol u l 9 4 v- 0 t = 1 . 6 m m smd mount surface ground terminal gnd connector ct connector s3b-ph-k-s, 2mm pitch, 3 pin manufactured by jst hokuriku electric industry co.,ltd. 180. 5 ??g??I?? (9 ) 300. 5 4 g mm 5 5 7 m ax 3. 4 m ax 1. 6typ 12m ax 1234 (4 ) (2 ) (2 ) (4 ) 1 2 3 1 2 3
4. absolute maximum ratings no. item rated value 1 rated voltage dc 0 ~ 7 v 2 operating temp. range -20 ~ +60 3 operating humidity range 20 ~ 90 %rh 4 storage temp. range -25 ~ +70 5 storage humidity range 0 ~ 90 %rh (do not let it have dewdrops.) 5. recommended line voltage range dc:5v +/- 0.25v 6. measuring circuit 6. electrical characteristics the condition regarding the table below is 25deg.c in temperature and operating voltage 5v. (the one for the output shift caus ed by the line voltage variation is not included.) item conditions min. typ max. unit 40%rh ------- 1.578 (-5%rh) 1.744 1.888 (+5%rh) v humidity detection output (accuracy) 60%rh ------- 2.120 (-5%rh) 2.220 2.318 (+5%rh) v consumption current cc 60%rh 1.30 ma hysteresis characteristics 30 ~ 90 %rh +/- 1 %rh humidity response characteristics 30%rh ? 90%rh wind speed 1.2 M /sec. (90% arrival) ------- 3.5 minutes hokuriku electric industry co.,ltd. h u mi d i ty se n so r u ni t digital multi-meter stabilized power supply vout humidity detection output vcc dc5v input 100k ohm 47 f
8. reliability tests no. test item test condition criteria 1 drop test d rop the test piece one time from the height of 1m in each of x, y and z directions onto the lauan material of 30 mm thickness. the sample shall not have any abnormality in the appearance and the humidity detection output shall be in the electric characteristics of item 7. 2 heat shock the samples are subjected to 10 cycles of 2 hours? exposure of each of ?25deg.c and +70deg.c (do not let it have dewdrops.) 3 exposure to high temperature the samples are exposed to a temp. of +70deg.c for 1000 hrs. 4 exposure to high humidity the samples are exposed to a temp. of +40deg.c with 95%rh for 1000 hrs. 5 exposure to low temperature the samples are exposed to a temp. of ?25deg.c for 1000 hrs. 6 load life the samples are subjected to a consecutive electric load in the normal temperature and humidity for 1000 hrs. the variation of the humidity detection output shall be within +/- 5% against the initial value. *1)the measurement of the humidity detection ou tput is done after 15 minutes has passed with the advantage way-type precision humi dity producing device after the temperature humidity setting. *2)the measurement of the reliability test parts is done after they are left for more than two hours in the normal temperature and the normal humidity. 9. notes for use (1)do not get the product wet in the water, and do not let it have dewdrops. characteristics may change permanently. (2)do not make foreign materials such as a solvent, oil and fat stick to the humidity sensor. it may stop fulfilling normal features. (3)do not use for medical apparatus (application involving risk of affecting life). hokuriku electric industry co.,ltd.
10. temperature humidity characteri stics of HSU-07 (for reference) h su -07? 0. 0 0. 5 1. 0 1. 5 2. 0 2. 5 3. 0 0 102030405060708090100 vout 5 25 45 temperature humidity characteristics of HSU-07 (for reference) 5deg.c 25deg.c 45deg.c