product information applications: features: tgs 2442 - for the detection of carbon monoxide the figure below represents typical sensitivity characteristics, all data having been gathered at standard test conditions (see reverse side of this sheet). the y-axis is indicated as sensor resistance ratio (rs/ro) which is defined as follows: rs = sensor resistance of displayed gases at various concentrations ro = sensor resistance in 100ppm co the figure below represents typical temperature and humidity dependency characteristics. again, the y-axis is indicated as sensor resistance ratio (rs/ro), defined as follows: rs = sensor resistance at 30ppm, 100ppm and 300ppm of co at various temperatures and 50%r.h. ro = sensor resistance at 300ppm of co at 25 c and 50% r.h. * co detectors * air quality controllers * indoor parking lot ventilation tgs 2442 utilizes a multilayer sensor structure. a glass layer for thermal insulation is printed between a ruthenium oxide (ruo 2) heater and an alumina substrate. a pair of au electrodes for the heater are formed on a thermal insulator. the gas sensing layer, which is formed of tin dioxide (sno 2 ), is printed on an electrical insulation layer which covers the heater. a pair of au electrodes for measuring sensor resistance are formed on the electrical insulator. activated charcoal is filled between the internal cover and the outer cover for the purpose of reducing the influence of noise gases. tgs 2442 displays good selectivity to carbon monoxide, making it ideal for co monitors. in the presence of co, the sensor's conductivity increases depending on the gas concentration in the air. a simple pulsed electrical circuit operating on a one second circuit voltage cycle can convert the change in conductivity to an output signal which corresponds to gas concentration. * low power consumption * high sensitivity/selectivity to carbon monoxide (co) * miniature size * low sensitivity to alcohol vapor * long life and low cost * low humidity dependency temperature/humidity dependency: sensitivity characteristics: 0.01 0.1 1 10 100 1 1 0 100 1000 10000 rs/ro gas concentration (ppm) air co ethanol h2 0.1 1 10 100 1000 -20-10 0 102030405060 rs/ro temperature (?c) air co 30ppm co 100ppm co 300ppm 50%rh important note: operating conditions in which figaro sensors are used will vary with each customers specific applications. figaro strongly recommends consulting our technical staff before deploying figaro sensors in your application and, in particular, when customers target gases are not listed herein. figaro cannot assume any responsibility for any use of its sensors in a product or application for which sensor has not been specifically tested by figaro.
basic measuring circuit: the value of sensitivity ( b ) is calculated with two measured values of rs as follows: sensor resistance (rs) is calculated with a measured value of vout as follows: rs = - rl preliminary specifications: vout rebmunledo m2442sgt epyttnemelegnisne s1m egakcapdradnat snaclatem5-ot sesagtegra tedixonomnobrac egnarnoitcetedlacipy tmpp0001~03 tiucricdradnats snoitidnoc elcycegatlovretaeh v h v hh v8.4= sm41,cdv2.0 v lh sm689,v0= elcycegatlovtiucric v c v c ,sm599rofv0= v c v0.5= sm5rofcdv2.0 ecnatsiserdaol r l (elbairav 3 k01 w ) scitsiretcarahclacirtcele tsetdradnatsrednu snoitidnoc ecnatsiserretaeh r h 71 5.2 w .pmetmoorta tnerrucretaeh i h vfoesacni(am302.xorppa hh ) rewopretaeh noitpmusnoc p h ).eva(wm41.xorppa ecnatsiserrosnes sr k18.6 w k1.86~ w fompp001ni edixonomnobrac ytivitisnes )srfooitaregnahc( b 94.0~32.0 snoitidnoctsetdradnats snoitidnocsagtset rianiedixonomnobrac 02ta 56,c?2 hr%5 snoitidnoctiucric noitidnoctiucric.dtssaemas )evoba( erofebdoirepgninoitidnoc tset )weiverrednu(syad2> rs (co,300ppm) rs (co,100ppm) b = structure and dimensions: cycle of 1 second. each v h cycle is comprised by 4.8v being applied to the heater for the first 14ms, followed by 0v pulse for the remaining 986ms. the vc cycle consists of 0v applied for 995ms, followed by 5.0v for 5ms. for achieving optimal sensing characteristics, the sensor's signal should be measured after the midpoint of the 5ms vc pulse of 5.0v ( for reference, see timing chart below ). note: application of a vc pulse condition is required to prevent possible migration of heater materials into the sensing element material. under extreme conditions of high humidity and temperature, a constant vc condition could result in such migration and cause long term drift of rs to higher values. a 5ms vc pulse results in significantly less driving force for migration than a constant vc condition, rendering the possibility of migration negligibly small. circuit voltage (v c ) is applied across the sensing element which has a resistance (rs) between the sensors two electrodes (pins no. 2 and no. 3) and a load resistor (r l ) connected in series. the sensing element is heated by the heater which is connected to pins no. 1 and no. 4. heating cycle --the sensor requires application of a 1 second heating cycle which is used in connection with a circuit voltage to facilitate usage of this sensor, TGS2442 is shipped in presorted groupings which have a more narrowly defined range of b: code: a: 0.23 ~ 0.34 d: 0.32 ~ 0.43 b: 0.26 ~ 0.37 e: 0.35 ~ 0.46 c: 0.29 ~ 0.40 f: 0.38 ~ 0.49 the above six classification will be further subdivided into the following rankings of rs values in 100ppm of co: code: 1: 6.81 ~ 21.5k w 3: 14.7 ~ 46.6k w 2: 10.0 ~ 31.6k w 4: 21.5 ~ 68.1k w bottom view ?9.2 0.2 ?8.1 0.2 ?0.3 5.9 0.2 1.5 top view ?6.0+0,-0.3 12.7 0.5 10.0 1.0 ?0.55 0.05 ?5.1 0.1 45? 1 4 32 unit: mm revised 03/00 1 technical information for TGS2442 technical information for carbon monoxide sensors the figaro TGS2442 sensor is a new type thick film metal oxide semiconductor, screen printed sensor which offers miniaturization and utilizes pulse heating for achieving low power consumption. the TGS2442 displays high selectivity to carbon monoxide together with improved humidity dependency and durability. specifications page features..................................................................................................2 applications...............................................................................................2 structure...........................................................................................2 basic measuring circuit...........................................................................2 circuit & operating conditions...............................................................3 mechanical strength..............................................................................3 dimensions...................................................................................................3 operation principle .........................................................................................................4 basic sensitivity characteristics sensitivity to various gases............................................................5 temperature and humidity dependency.............................................5 gas response pattern.................................................................................6 heater voltage dependency...........................................................................6 initial action.........................................................................................7 influence of unenergized storage...............................................................7 reliability interference gas test......................................................................................8 long-term stability................................................................................9 corrosion test...........................................................................................9 variable ambient temperature test...............................................................9 humidity test.............................................................................................10 stability tests...................................................................................................10 circuit examples basic circuit including trouble detection...............................................11 calibration and temperature compensation.............................................11 marking and packaging ..................................................................................................13 see also technical brochure technical information on usage of tgs gas sensors for explosive/toxic gas alarming. an iso9001 company impor t ant note: operating conditions in which figaro sensors are used will vary with each customers specific applications. figaro strongly recommends consulting our technical staff before deploying figaro sensors in your application and, in particular, when customers target gases are not listed herein. figaro cannot assume any responsibility for any use of its sensors in a product or application for which sensor has not been specifically tested by figaro. revised 03/00 2 technical information for TGS2442 1. specifications 1-1 features * miniature size and low power consumption * high sensitivity/selectivity to carbon monoxide (co) * low sensitivity to alcohol vapor * reduced influence by various interference gases * long life and low cost 1-2 applications * residential and commercial co detectors * air quality controllers * ventilation control for indoor parking garages 1-3 structure figure 1 shows the structure of TGS2442. the sensor utilizes a multilayer structure. a glass layer for thermal insulation is printed between a ruthenium oxide (ruo2) heater and an alumina substrate. a pair of au electrodes for the heater are formed on a thermal insulator. the gas sensing layer, which is formed of tin dioxide (sno2), is printed on an electrical insulation layer which covers the heater. a pair of pt electrodes for measuring sensor resistance is formed on the electrical insulator. an activated charcoal filter is used for the purpose of reducing the influence of noise gases. 1-4 basic measuring circuit figure 2 shows the basic measuring circuit of the TGS2442. circuit voltage (vc) is applied across the sensing element which has a resistance (rs) between the sensors two electrodes (pins no. 2 and no. 3) and a load resistor (r l ) connected in series. the sensing element is heated by the heater which is connected to pins no. 1 and no. 4. the sensor requires application of a 1 second heating cycle which is used in connection with a circuit voltage cycle of 1 second. each v h cycle is comprised by 4.8v being applied to the heater for the first 14ms, followed by 0v for the remaining 986ms. the vc cycle consists of 0v applied for 995ms, followed by 5.0v for 5ms. for achieving optimal sensing characteristics, the sensor's signal should be measured after the midpoint of the 5ms vc pulse of 5.0v ( for illustration, see the timing chart in fig. 3 ). note: application of a vc pulse condition is required to prevent possible migration of heater materials into the sensing element material. under extreme conditions of high humidity and temperature, a constant vc condition could result in such migration and cause long term drift of rs to higher values. a 5ms vc pulse results in significantly less driving force for migration than a constant vc condition, rendering the possibility of migration negligibly small. figure 1 - sensor structure figure 2 - basic measuring circuit (including equivalent circuit) metal base substrate lead wire charcoal filter metal cap top view of the sensor without cap 2 1 3 4 non woven fabric metal gauze (double layer) lead pin noble metal electrode revised 03/00 3 technical information for TGS2442 1-5 circuit & operating conditions the following conditions should be maintained to ensure stable sensor performance: figure 4 - dimensions withstand force > 5kg in each direction frequency--10-500hz (equiv. to 10g), duration-6 hours, x-y-z direction acceleration-100g, repeat 5 times figure 3 - circuit voltage and heater voltage cycles rs = vc x r l v out - r l rs (co,300ppm) rs (co,100ppm) formula for calculation of sensor resistance: sensitivity (change ratio of rs) is calculated with two measured values of rs as follows: r e b m u n l e d o m2 4 4 2 s g t e p y t t n e m e l e g n i s n e s1 m e g a k c a p d r a d n a t sn a c l a t e m 5 - o t s e s a g t e g r a te d i x o n o m n o b r a c e g n a r n o i t c e t e d l a c i p y tm p p 0 0 0 1 ~ 0 3 t i u c r i c d r a d n a t s s n o i t i d n o c e l c y c e g a t l o v r e t a e h v h v h h v 8 . 4 = s m 4 1 , c d v 2 . 0 v l h s m 6 8 9 , v 0 = e l c y c e g a t l o v t i u c r i c v c v c , s m 5 9 9 r o f v 0 = v c v 0 . 5 = s m 5 r o f c d v 2 . 0 e c n a t s i s e r d a o l r l ( e l b a i r a v k 0 1 w ) s c i t s i r e t c a r a h c l a c i r t c e l e t s e t d r a d n a t s r e d n u s n o i t i d n o c e c n a t s i s e r r e t a e h r h 7 1 5 . 2 w . p m e t m o o r t a t n e r r u c r e t a e h i h v f o e s a c n i ( a m 3 0 2 . x o r p p a h h ) r e w o p r e t a e h n o i t p m u s n o c p h ) . e v a ( w m 4 1 . x o r p p a e c n a t s i s e r r o s n e s s r k 1 8 . 6 w k 1 . 8 6 ~ w f o m p p 0 0 1 n i e d i x o n o m n o b r a c y t i v i t i s n e s ) s r f o o i t a r e g n a h c ( b 9 4 . 0 ~ 3 2 . 0 s n o i t i d n o c t s e t d r a d n a t s s n o i t i d n o c s a g t s e t r i a n i e d i x o n o m n o b r a c 0 2 t a 5 6 , c ? 2 h r % 5 s n o i t i d n o c t i u c r i c n o i t i d n o c t i u c r i c . d t s s a e m a s ) e v o b a ( e r o f e b d o i r e p g n i n o i t i d n o c t s e t ) w e i v e r r e d n u ( s y a d 2 > to facilitate usage of this sensor, TGS2442 is shipped in presorted groupings which have a more narrowly defined range of b : code: a: 0.23~ 0.34 d: 0.32 ~ 0.43 b: 0.26 ~ 0.37 e: 0.35 ~ 0.46 c: 0.29 ~ 0.40 f: 0.38 ~ 0.49 the above six classification will be further subdivided into the following rankings of rs values in 100ppm of co: code: 1: 6.81 ~ 21.5k w 3: 14.7 ~ 46.6k w 2: 10.0 ~ 31.6k w 4: 21.5 ~ 68.1k w 1-6 mechanical strength the sensor shall have no abnormal findings in its structure and shall satisfy the above electrical specifications after the following performance tests: withstand force - (pin from base) vibration - shock - 1-7 dimensions (see fig. 4) b = bottom view ?9.2 0.2 ?8.1 0.2 ?0.3 5.9 0.2 1.5 top view ?6.0+0,-0.3 12.7 0.5 10.0 1.0 ?0.55 0.05 ?5.1 0.1 45? 1 4 32 revised 03/00 4 technical information for TGS2442 2. operation principle the optimum conditions of sensitivity and selectivity to co of the TGS2442 occurs at sensor temperatures less than 100?c. however, at these lower temp- eratures, the sensing element may be influenced by humidity and other contaminants, so the sensing element requires periodic heat cleaning at more than 300?c. as a result, the TGS2442 is pulse heated to achieve optimal sensing characteristics at low temperatures. figure 6a shows the pattern of resistance change ratio (rs/ro) for various co concentrations which occurs during the 1 second heater pulse cycle, starting with application of the 14ms v h pulse. during the v h pulse, initially sensor resistance drops quickly and then returns to a higher value. after the v h pulse concludes and the sensing elements surface temperature begins to decrease (fig. 6b), sensor resistance reaches to its maximum value and then begins to decline. note that the shape of the response pattern varies according to the concentration of co- -higher co concentrations result in a minimum rs/ ro value which occurs more quickly and has a lower value. in addition, shortly after the v h pulse, the rs/ro value also trends downwards at a greater rate for higher co concentrations after reaching its maximum value. a signal detection point of 997.5ms into the v h pulse cycle ( ref. timing chart in fig. 3 ) is used to obtain the optimum combination of gas sensitivity performance and minimized ambient humidity effect. figure 5 - relationship of sensor temperature and v h pulse width (v h =4.8v, r h =17 w ) figure 6a - sensitivity characteristics during the v h pulse cycle (ro = rs in 100ppm co at 997.5ms of v h cycle) 0 50 100 150 200 250 300 350 400 0 5 10 15 20 temperature (?c) vh pulse width (msec) figure 6b - surface temperature of sensing element during v h pulse cycle (0msec = start of v h pulse cycle) 0.1 1 10 100 0 200 400 600 800 1000 rs/ro time (msec) air co 30ppm co 300ppm co 100ppm detection point (997.5 msec) 14ms vh pulse 10 100 1000 0 200 400 600 800 1000 temp (?c) time (msec) 14ms vh pulse detection point (997.5 msec.) revised 03/00 5 technical information for TGS2442 3. basic sensitivity characteristics 3-1 sensitivity to various gases figure 7 shows the sensors relative sensitivity to various gases. the y-axis shows the ratio of sensor resistance in various gases (rs) to the sensor resistance in 100ppm of co (ro). as shown by figure 7, TGS2442 shows very good sensitivity to co since the sensitivity curve to co shows a sharp drop in sensor resistance as co concentration increases. in comparison, sensitivity to ethanol (c 2 h 5 oh) is very low as evidenced by the relatively flat slope of its sensitivity curve and high resistance values. the amount of co generated by cigarette smoke is roughly equivalent to 20ppm of co when 10 cigarettes are smoked in a room of roughly 24 cubic meters in size. as a result, the influence of cigarette smoke itself would not be sufficient to cause the sensor to generate an alarm for residential detectors using TGS2442 which are normally calibrated to alarm at 100ppm of co. 3-2 temperature and humidity dependency figure 8a shows the temperature dependency of TGS2442. the y-axis shows the ratio of sensor resistance for various co concentrations under various temperature conditions (rs) to the sensor resistance in 100ppm of co at 50%rh (ro). figure 8b shows the humidity dependency of TGS2442. the y-axis shows the ratio of sensor resistance for various co concentrations under various relative humidity conditions (rs) to the sensor resistance in 100ppm of co at 20?c. an inexpensive way to compensate for temperature dependency to a certain extent would be to incorporate a thermistor in the detection circuit (please refer to section 5-2) . figure 7 - sensitivity to various gases (ro = rs in 100ppm of co) 0.01 0.1 1 10 100 1 10 100 1000 10000 rs/ro gas concentration (ppm) air co ethanol h2 0.1 1 10 100 1000 -20-10 0 102030405060 rs/ro temperature (?c) air co 30ppm co 100ppm co 300ppm 50%rh 0.1 1 10 100 0 20406080100 rs/ro humidity (%rh) air co 30ppm co 100ppm co 300ppm 20?c figure 8a - temperature dependency at 50%rh (ro = rs in 100ppm of co at 20?c) figure 8b - humidity dependency at 20?c (ro = rs in 100ppm of co at 50%rh) revised 03/00 6 technical information for TGS2442 3-3 gas response pattern the response pattern of the TGS2442 sensor is similar to that of a constant v h sensor since data acquisition is carried out once every second during operation. figure 9 shows the pattern of the output signal when the sensor is placed into 70, 150, and 400ppm of co and then returned to normal air. the response time to 90% of the saturated signal level is roughly 3.3 minutes and the recovery of the sensor to 90% of the base level is within 10 minutes. this data demonstrates that TGS2442 possesses sufficient response speed for meeting ul requirements for co detectors. 3-4 heater voltage dependency the TGS2442 should be used with a heater voltage of 4.8 0.2v. although at the detection point the sensors temperature is close to room temperature, its gas sensing characteristics are affected by heater voltage as can be seen in figure 10. at lower heater voltage, the rs/ro decreases and the difference in sensitivity between co concentrations narrows. if heater voltages is higher, sensor resistance increases. figure 9 - TGS2442 response pattern in 70, 150, and 400ppm co figure 10 - heater voltage dependency (ro = rs at 100ppm of co and v h =4.8v) 0.1 1 10 4.2 4.4 4.6 4.8 5.0 5.2 5.4 co 30ppm co 100ppm co 300ppm rs/ro heater voltage (v) 10 100 1000 0 20 40 60 80 100 120 140 160 rs (k w ) time (min) 150ppm co 70ppm co 400ppm co air air air revised 03/00 7 technical information for TGS2442 3-5 initial action figure 11 shows the initial action of the sensors resistance. for purposes of this test, the sensor was stored unenergized in normal air for 40 days after which it was energized in clean air. after energizing, the sensors resistance reaches to 90% of its final value in less than one minute, an alarm delay circuit should be incorporated into detectors using TGS2442 to prevent activation of an alarm during this period. 3-6 influence of unenergized storage figure 12 shows the influence of unenergized storage on sensor resistance. sensors were stored unenergized in normal air for 30 days after which they were energized. the y-axis represents the ratio of sensor resistance in various concentrations of co after the unenergized period (rs) to the resistance in 100ppm of co after energizing at the rated voltage for 4 days (ro). this chart shows that after energizing, unlike the sensor resistance in clean air (as shown in fig. 11), resistance in co first decreases slightly and then returns to a stable level, demonstrating the need for adhering to the recommended preheating period prior to calibration. figure 11 - initial action (ro = rs after 20 minutes of energizing) figure 12 - time dependency (ro = rs in 100ppm of co after 4 days, n=20) 0.1 1 10 02468101214 co 30ppm co 100ppm co 300ppm rs/ro time (days) 0.1 1 10 0 5 10 15 20 25 30 rs/ro time (min.) revised 03/00 8 technical information for TGS2442 4. reliability tests conducted in this section demonstrate that TGS2442 can meet the requirements of various testing standards without incurring adverse long term effects from such tests. 4-1 interference gas test figure 13 shows the results of testing the TGS2442 sensor for durability against various interference gases specified by gri test protocol 1. the test was conducted by exposing the sensor to each gas shown in fig. 13 (starting with co 100ppm) for two hours, then removing the sensor to fresh air for just under one hour, and followed by inserting the sensor into the next test gas. this procedure was repeated for the full range of gases shown in fig. 13. because the sensor is exposed to each of the test gases consecutively, to some small extent the effect of the previous test gas may affect subsequent tests for a short period. however, despite the short-term effects of such gases remaining after exposure, the sensor still shows significantly less sensitivity to each test gas when compared to 100ppm of co, and co sensitivity remains unaffected. figures 14 and 15 show data from tests conducted using interference gases listed in the ul2034 standard for selectivity test (sec. 38) which are deemed to represent air contaminants likely to be found in the vicinity of an installed co detector. data for figure 14 was collected by exposing samples in each of the test gases for a period of two hours as required by the ul standard. sensor resistance at both the initial point and at the conclusion of test gas exposure was recorded. when compared to the sensors measured resistance in 100ppm of co (ro), in all cases the resistance in test gas remained at more than 40 times that of resistance in 100ppm of co, showing the sensor to have negligible influence by these gases. figure 15 demonstrates that sensor subjected to the interference gas tests do not change their characteristics after exposure to these gases. samples subjected to the interference gas test were compared to reference samples (not subjected to the interference gas tests). over a two week period, when not undergoing gas test, all samples were energized in fresh air under standard circuit conditions. this data suggests that TGS2442 shows good durability against every gas used in gri test protocol 1 and meets the requirements of ul2034. fig. 13 - effects of interference gases (gri test protocol 1) (ro = rs in co 100ppm) 0 20 40 60 80 100 rs/ro co 100ppm co 100ppm ethylene 200ppm nitrous oxide 200ppm nitric oxide 50ppm trichloroethane 200ppm toluene 200ppm ethanol 200ppm acetone 200ppm ammonia 100ppm co2 5000ppm isopropanol 200ppm ethyl acetate 200ppm heptane 500ppm butane 300ppm methane 500ppm acrylic cement 10g 0 10 20 30 40 50 60 70 80 initial value after 2 hrs. rs/ro 0. 1 10 100 02468101214 co 30ppm (ref) co 100ppm (ref) co 300ppm (ref) co 30ppm (test) co 100ppm (test) co 300ppm (test) rs/ro time (days) test figure 14 - selectivity test (ul2034, sec. 38) (ro = rs in co 100ppm) figure 15 - stability of sensors subjected to selectivity test (ro = rs in co 100ppm on day 6) methane isobutane heptane co2 ethyl acetate isopropanol 500ppm 300ppm 500ppm 5000ppm 200ppm 200ppm revised 03/00 9 technical information for TGS2442 4-2 long-term stability figure 16 shows long-term stability data for TGS2442. test samples were energized in normal air and under standard circuit conditions. measurement for confirming sensor characteristics was conducted under standard test conditions (20?c, 65%rh). the initial value was measured after four days of energizing in normal air at the rated voltage. the y- axis shows the ratio between measured sensor resistance and the initial (day 4) resistance value, each in 100ppm of co. additional data will be published as it becomes available. 4-3 corrosion test to demonstrate the durability of TGS2442 against corrosion, samples were subjected to test conditions called for by ul2034, sec. 57-corrosion test. over a three week period, a mixture of 100ppb of h 2 s, 20ppb of cl 2 , and 200ppb of no 2 was supplied to the sensor at a rate sufficient to achieve an air exchange of 5 times per hour. when compared to reference samples not subjected to these corrosive gases, no significant difference can be noticed. 4-4 variable ambient temperature test to show the ability of TGS2442 to withstand the effects of high and low temperatures representative of shipping and storage, the sensor was subjected to the test conditions of ul2034 sec. 44.2-effect of shipping and storage. unenergized test samples were subjected to 70?c for 24 hours, allowed to cool to room temperature for 1 hour, subjected to -40?c for 3 hours, and then allowed to warm up to room temperature for 3 hours. when compared to reference samples not subjected to these temperature extremes, no significant difference can be noticed. figure 16 - long term stability (ro = rs in 100ppm of co at day 4) 0.1 1 10 100 1000 0 50 100 150 200 250 300 350 air co 30ppm co 100ppm co 300ppm h2 1000ppm etoh 1000ppm rs/ro time (days) figure 17 - durability against corrosion (ro = rs in 100ppm of co at day 2) figure 18 - variable ambient temperature test (ro = rs in 100ppm of co at day 0) 0. 1 10 0 5 10 15 20 25 30 co 30ppm (ref) co 100ppm (ref) co 300ppm (ref) co 30ppm (test) co 100ppm (test) co 300ppm (test) rs/ro time (days) test 3 hrs. after test 0.1 1 10 0 5 10 15 20 25 30 35 40 co 30ppm (ref) co 100ppm (ref) co 300ppm (ref) co 30ppm (test) co 100ppm (test) co 300ppm (test) rs/ro time (days) test revised 03/00 10 technical information for TGS2442 4-5 humidity test figure 19 shows the comparison of reference sensors to those energized and exposed in an atmosphere of 52?c and 95% rh for a period of 168 hours, returned to normal air for 2 days, then followed by 168 hours in 20?c/15%rh as required by ul2034 sec. 46a.1- humidity test. as the test measurements taken after the conclusion of the humidity test demonstrate, sensors subjected to the test show influence by humidity, but the sensor quickly returns to its normal value. 4-6 stability test (1) false alarm test to show the sensors behavior under continuous low level exposure to co, samples were tested against the procedure detailed in ul2034, sec. 41.1(c)- stability test. test samples were exposed to 30ppm continuously for a period of 30 days under standard circuit conditions. as this data demonstrates, false alarming does not occur as a result of continuous low level co exposure. (2) temperature cycle test in accordance with ul2034, sec. 41.1(e)-stability test, test samples were exposed to ten cycles (< 1 hr. and > 15 min.) of temperature from 0?c and 100%rh to 49?c and 40%rh. as the three test measurements taken after the conclusion of the test period demonstrate, sensors subjected to the test show negligible influence by temperature extremes. 1 10 100 012345678 co 30ppm (ref) co 100ppm (ref) co 300ppm (ref) co 30ppm (test) co 100ppm (test) co 300ppm (test) rs/ro time (days) test after 8 hrs. 0.1 1 10 100 0 5 10 15 20 25 co 30ppm (ref) co 100ppm (ref) co 300ppm (ref) co 30ppm (test) co 100ppm (test) co 300ppm (test) rs/ro time (days) 52?c/95%rh 20?c/15%rh 0.1 1 10 0 1020 3040 5060 co 30ppm (ref) co 100ppm (ref) co 300ppm (ref) co 30ppm (test) co 100ppm (test) co 300ppm (test) rs/ro time (days) start test end test figure 19 - humidity test (ro = rs in 100ppm of co at day 0) figure 20 - false alarm test (ro = rs in 100ppm of co prior to test) figure 21 - temperature cycle test (ro = rs in 100ppm of co prior to test) revised 03/00 11 technical information for TGS2442 5. circuit examples 5-1 basic circuit including trouble detection figure 22 - basic circuit ( including trouble detection ) figure 23 - calibration & temperature compensation s-in 8-bit a/d input port h-in 8-bit a/d input port r-in 8-bit a/d input port (each of these ports acquires data at preset timing.) r l1 ,r l2 open drain output port pulse open drain output port temp open drain output port calb open drain output port circuit voltage (vc) across the sensor is applied when rl1 or rl2 ports give the low (l) output signal at preset timing. v1 sampling voltage for gas detection v2 sampling voltage for sensor element trouble detection v3 sampling voltage for reference voltage v4 sampling voltage for temperature compensation v5,v6 sampling voltage for detecting heater circuit breakage v1 and v2 are acquired during the last half of the 5msec v c pulse (the first half of the v c pulse is considered as the transient period). v5 is acquired during heater off, and v6 is acquired during heater on pulse. r a = 50% of vc at the targeted gas concentration r b = 200-300k w r c = 10k w r d = 20k w r e = 10k w v radj = 100k w thermistor: r (25?c) = 10k w , b constant = 3400 5-2 calibration and temperature/humidity compensation rs = r calb = k temp = 5 - v1 v1 5 - v3 v3 5 - v4 v4 e t a t s s n o i t i d n o c l a m r o nk x s r p m e t r > b l a c d n a 2 v v 5 . 0 m r a l ak x s r p m e t r b l a c d n a 2 v v 5 . 0 n o i t c n u f l a m r o s n e sv 5 . 0 < 2 v n o i t c n u f l a m r e t a e h5 v v 1 . 0r o 6 v v 5 . 4 operation state: sensor resistance (rs): calibration resistance (r calb ): coefficient for temp. compensation (k temp ): revised 03/00 12 technical information for TGS2442 example of application circuit for TGS2442 revised 03/00 13 technical information for TGS2442 6. marking and packaging 6-1 batch number rank and lot. no. are indicated on the shrink wrap on the side of the sensor cap as shown in figure 24. 6-2 packaging method (fig. 25) fifty (50) pieces of sensor are packed in a plastic container, and five (5) containers are sealed inside a moistureproof aluminum coated bag. several bags are then packed in a carton box ( see fig. 26 ). 6-3 label a label showing product name, rank and lot no., quantity, and inspection date is affixed to the aluminum coated bag. 6-4 handling instructions it is recommended to begin sensor preheating within 24 hours after opening a sealed bag. please keep unused sensors in a tightly sealed moistureproof bag. rank lot no. a1 001512 trace no. week (01-52) gas testing year (00-99) based on rs 100ppm co (1-4) based on b value (a-f) plastic container for 50pcs. (188 x 188mm) aluminum coated bag - holds 250pcs. (265 x 300mm) label x 5 figure 24 - batch number coding figure 25 - packing methodology figure 26 - carton box 2000pcs. (250 pcs. x 8 bags) bag (250 pcs.) revised 04/01 1 calibration of TGS2442 page basic circuit structure..................................................................2 method of signal processing basic flow.............................................................................2 detection of sensor-related trouble conditions............................2 calculation of co concentration sensor resistance (rs) calculation..................................4 temperature compensation of ?(rs)..................................4 compensation for variation in rs grades......................5 compensation for variation within b grades......................5 converting ?(rs ) to co concentration output...............5 calibration using classified sensors preheating...................................................................................6 pre-calibration select a load resistor............................................6 compensation according to b grade.................................6 main calibration....................................................................7 appendix-calibration at two or more concentrations...................8 ability of sensor to meet performance standards requirements of performance standard.......................................8 estimation of calibration accuracy.................................9 conclusion........................................................................9 signal processing and calibration techniques for co detectors using TGS2442 this brochure offers users important technical advice for handling and calibration of the TGS2442 co sensor, including calibration techniques using a microprocessor. detector circuit and calibration facility design should be carried out with these points in mind. impor t ant note: operating conditions in which figaro sensors are used will vary with each customers specific applications. figaro strongly recommends consulting our technical staff before deploying figaro sensors in your application and, in particular, when customers target gases are not listed herein. figaro cannot assume any responsibility for any use of its sensors in a product or application for which sensor has not been specifically tested by figaro. revised 04/01 2 calibration of TGS2442 in order to meet the various regulations to which co detectors are subject, circuit design and method of calibration should be based on the performance of the gas sensor. recommended procedures for usage of the TGS2442 co sensor are set forth in this document. 1. basic circuit structure circuit structure needed to satisfy performance standards should provide for complex signal process- ing, necessitating usage of a microcomputer with features such as those shown in table 1. this microcomputer will process multiple signals from the sensor, a thermistor (for temperature compensation), and a potentiometer (for calibration). the microcom- puter will output a control signal for alarm operation. the following six types of output signals should be monitored ( refer to the sample circuit diagrams and timing charts in figs. 1 and 2 on the facing page ): v1: sampling voltage for gas detection v2: sampling voltage for sensor element trouble detection v3: sampling voltage for reference voltage v4: sampling voltage for temperature compensation v5,v6: sampling voltage for detecting heater trouble e r o c u p c r e t u p m o c o r c i m t i b 8 r o 4 ) k c o l c z h m 8 ~ 2 h t i w ( e z i s y r o m e m m o r e t y b k 4 ~ 2 m a r e t y b r o e l b b i n 6 5 2 ~ 8 2 1 e z i s n i ps n i p 2 3 ~ 8 2 n o i t p o r e t r e v n o c d / a t i b - 8 ) s l e n n a h c 3 n a h t e r o m ( e v i r d t c e r i d t n e r r u c h g i h ) s t r o p 6 n a h t e r o m ( e d o m t r o p n o i t c e l e s l a m r o n r o n o i t a r b i l a c t c e l e s s e d o m n o i t a r e p o table 1 - recommended microcomputer features power on alarm delay for initial action v1~v6 sampling sensor trouble detection co calculation display co concentration convert to cohb concentration alarm determination suppress alarm generate alarm generate trouble signal main routine (1 sec. cycle) yes no yes no figure 3 - basic flow of detector operation * * if applicable 2. method of signal processing 2-1. basic flow figure 3 shows the basic flow of detector operation. to avoid potential nuisance alarming during the sensors initial action period, a warm-up period of several minutes (alarm delay) should be utilized upon initial powering of the detector. after this period, the program in the microcomputer starts the main gas detection routine. during the gas detection routine, the above mentioned six output signals are acquired during each one second interval. v2, v5 and v6 are used for detecting sensor-related trouble and heater driving circuit malfunction while v1, v3 and v4 are used to calculate co gas concentration. this concentration is subsequently converted by time- weighting into a cohb concentration ( the key measurement used in performance standards for determining the generation of alarm signals ). 2-2. detection of sensor-related trouble conditions the sensor trouble mode should indicate that the sensors heater has broken or that the sensor element itself has been damaged. the trouble signal for heater breakage can be detected by an abnormal rise in heater resistance or as a result of lead wire breakage, transistor problems, and/or short of the heater. the sensor element trouble signal is generated by damage to the sensing material or breakage of a lead wire. these phenomena produce an extreme change to the values of v5, v6 and v2; consequently monitoring v5, v6 and v2 enables detection of sensor-related trouble conditions. see table 2 for recommended conditions for monitoring sensor-related trouble. table 2 - conditions under which an trouble signal should be generated e l b u o r t r e t a e h 5 v 3 v 1 . 0 6 v v 5 . 4 e g a m a d t n e m e l e r o s n e s2 v v 5 1 . 0 revised 04/01 3 calibration of TGS2442 figure 1 - basic circuit ( including trouble detection ) figure 2 - calibration & temperature compensation legend of circuit diagrams s-in 8-bit a/d input port h-in 8-bit a/d input port r-in 8-bit a/d input port (each of these ports acquires data at preset timing.) rl1 open drain output port rl2 open drain output port pulse open drain output port temp open drain output port calb open drain output port circuit voltage (vc) across the sensor is applied when rl1 or rl2 ports give the low (l) output signal at preset timing. v1 and v2 are acquired during the last half of the 5msec v c pulse (the first half of the v c pulse is considered as the transient period). v5 is acquired during heater off, and v6 is acquired during heater on pulse. r a = closest value to rs at calibrated co concentration r b = 300k w r c = 10k w r d = 20k w v radj = 100k w thermistor: r (25?c) = 15k w , b constant = 4200 revised 04/01 4 calibration of TGS2442 2-3. calculation of co concentration figure 4 illustrates the process for calculating co concentration from v1, v3 and v4 signals. sample v1, v3, v4 a. calculation of ?(rs) value b. temperature compensation of ?(rs) value c. compensation for rs grade variation d. compensation for b grade e. convert to co concentration output figure 4 - signal processing flow for calculation of co concentration 0.01 0.1 1 10 100 100 1000 rs/ro co concentration (ppm) 40%rh 0?c 15?c 25?c 35?c 40?c 50?c 0.01 0.1 1 10 100 100 1000 rs/ro co concentration (ppm) 40%rh 0~50?c figure 5a - temperature dependency of rs (ro = rs at 100ppm co, 25?c/40%rh) figure 5b - ?(rs) value compensated for temperature [?(rs ? )] (ro = rs at 100ppm co, 25?c/40%rh) ?(rs ? )/?(ro) e u l a v t u p n i 4 v ) c ? ( p m e t k p m e t t n e i c i f f e o c 5 1 . 40 1 -2 7 . 2 2 9 . 35 -4 3 . 2 6 6 . 309 9 . 1 7 3 . 350 7 . 1 6 0 . 30 16 4 . 1 5 7 . 25 17 2 . 1 4 4 . 20 22 1 . 1 4 1 . 25 20 0 . 1 6 8 . 10 39 0 9 . 0 1 6 . 15 39 3 8 . 0 8 3 . 10 46 8 7 . 0 8 1 . 15 44 4 7 . 0 1 0 . 10 52 1 7 . 0 6 8 . 05 57 8 6 . 0 3 7 . 00 68 6 6 . 0 table 3 - table of temperature compensation coefficients a. sensor resistance (rs) calculation: to represent sensor resistance (rs) value in the microcomputer, the expression ?(rs) shall be used: ?(rs) = ( 5 - v1 ) / v1 b. temperature compensation of ?(rs) in order to compensate for the temperature dependency of ?(rs) value, a temperature compen- sation coefficient (k temp ) must be determined. k temp = rs/ro , where rs = actual sensor resistance in various conditions ro = actual sensor resistance under standard conditions using the circuit condition and recommended thermistor in figs. 1 & 2, measure actual rs values at various ambient temperatures and sample thermistor output (v4). the correlation between v4 and k temp can be obtained by this procedure and should be written as a table of coefficients into rom on the microcomputer. then, by monitoring v4 output during normal operations, the proper k temp value can be selected from the table and used to temperature compensate ?(rs) values according to the following formula: ?(rs ? ) = ?(rs) / k temp ?(rs ? ) represents temperature compensated ?(rs). table 3 shows an example coefficient table for temp- erature compensation where measuring 100ppm of co in 25 c/40%rh is used as a standard condition. figures 5a and 5b show typical values of ?(rs) before and after temperature compensation. revised 04/01 5 calibration of TGS2442 c. compensation for variation within rs grades variation in absolute rs values among sensors within any given grade should be normalized by adjusting ?(rref) as part of the calibration process. ?(rref) = ( 5 - v3 ) / v3 ?(rs ) is defined as a variation compensated ?(rs ? ) value: ?(rs ) = ?(rs ? ) / ?(rref) to calibrate the sensor correctly, ?(rs ) should be equal to 1.0 at the desired concentration. to do this, change v3 values by adjusting vradj. figures 6a and 6b show the variation within rs grades and the result of compensating for such rs variation. d. compensation for variation within b grades variation in sensitivity slopes ( a ) among sensors within any b grade should be compensated in the calibration process. this requires that a second ?(rs ) value (at 300ppm of co, for example) be obtained: * measure actual ?(rs) at second co concentration * calculate ?(rs ) for the second concentration * using the ?(rs ) values for the two concentrations, calculate the slope ( a ): log ?(rs ) (300ppm) - log ?(rs ) (100ppm) log 300 - log 100 * store the a value in the microcomputer e. converting ? (rs ) to co concentration output using the sensitivity curve slope ( a ) determined above, actual co concentration (c) can be calculated for usage in conversion to cohb: c = 100 x ? (rs ) 1/ a 0.01 0.1 1 10 10 100 1000 rs/ro co concentration (ppm) max min center 0.01 0.1 1 10 10 100 1000 rs/ro co concentration (ppm) figure 6a - rs variation within rs grades (ro = rs at 100ppm co, 25?c/40%rh) figure 6b - rs variation compensation (ro = rs at 100ppm co, 25?c/40%rh) ?(rs ? )/?(ro) rs 1 /ro a = 0.1 1 10 10 100 1000 rs/ro co concentration (ppm) center max min figure 7 - a variation within b grades (ro = rs at 100ppm co, 25?c/40%rh) rs 1 /ro ?(rs )/?(ro) ?(rs )/?(ro) revised 04/01 6 calibration of TGS2442 3. calibration using classified sensors this section describes the procedure for calibrating at 100ppm of co using sensors classified as shown in tables 4 and 5. figure 8 illustrates the flow of the calibration process, including the method of signal processing which takes place in the microcomputer. 3-1. preheating to stabilize sensor characteristics prior to calibration, it is recommended that sensors be preheated under standard circuit conditions for 2 - 7 days. to shorten preheating time and simplify this process, figaro is currently studying alternative methods and will issue new recommendations shortly. 3-2. pre-calibration (adjustment during assembly) a. select a load resistor (r l ) select the load resistor (r l , same as ra in figure 1) based on the rs grade shown in table 4. for optimal resolution, the r l used should have a value as close as possible to the rs grades center value. the sensor output signal (v1) at the calibration concentration should be near 2.5v which is 1/2 the value of vc. according to the maximum and minimum values of rs values for each rs grade as shown in table 4, v1 would fall in the following range: 1.70 v v1 (at 100ppm) 3.30 v b. compensation according to b grade each rs grade is divided into six b grades as shown in table 5. using data from this table, a values for these grades can be determined as follows and should be stored in the microcomputer (see table 6): a = log b (center) / log (300/100) using the a value calculated above, compensation for b grade can be done by utilizing a circuit such as that shown in figure 9 and connecting the three jumper lines as indicated in table 6. e d a r g b b b b b ) m p p 0 0 1 n i s r / m p p 0 0 3 n i s r ( . n i m r e t n e c . x a m a0 3 2 . 05 8 2 . 00 4 3 . 0 b0 6 2 . 05 1 3 . 00 7 3 . 0 c0 9 2 . 05 4 3 . 00 0 4 . 0 d0 2 3 . 05 7 3 . 00 3 4 . 0 e0 5 3 . 05 0 4 . 00 6 4 . 0 f0 8 3 . 05 3 4 . 00 9 4 . 0 e d a r g k ( m p p 0 0 1 o c n i s r w ) d e d n e m m o c e r r l k ( w ) . n i m r e t n e c . x a m 11 8 . 61 . 2 15 . 1 22 1 20 . 0 18 . 7 16 . 1 38 1 37 . 4 11 . 6 24 . 6 47 2 45 . 1 23 . 8 31 . 8 69 3 table 4 - rs grades of TGS2442 table 5 - b grades of TGS2442 figure 9 - recommended circuit for b grade compensation b b b b b e d a r g a a a a a e u l a v r e p m u j n o i t c e n n o c a4 1 . 1 -1 0 0 b5 0 . 1 -0 1 0 c9 6 9 . 0 -1 1 0 d2 6 8 . 0 -0 0 1 e3 2 8 . 0 -1 0 1 f8 5 7 . 0 -0 1 1 table 6 - recommended jumper connections for b grade compensation circuit revised 04/01 7 calibration of TGS2442 preheat sensor pre-calibration burn-in detector set microcomputer to calibration mode insert into gas chamber expose to 100ppm co power reset on vent gas adjust vradj deactivate calibration mode on microcomputer end calibration begin calibration mode sensor stabilization sample v1 (sensor output) and v4 (thermistor output) calculate ?(rs) determine k temp calculate ?(rs ? ) (100) and store in memory continuous sampling of v3 (reference voltage) calculate ?(rref) continuously adjust ?(rref) to the threshold value step 1 step 4 step 3 step 2 * selection of r l - sec. 3-2(a) b grade compensation - sec. 3-2(b) * calibration signal pr ocessing in the micr ocomputer figure 8 - calibration and signal processing in the microcomputer 3-3. main calibration (using calibration mode in the microcomputer ) using the mode selection port on the microcomputer, select calibration mode. switch the detector on (reset), activating calibration mode. signal processing in the microcomputer during the calibration mode proceeds as shown in figure 8. place the detector in a vessel which is then filled with 100ppm of co. step 1: stabilize sensor output v1 in 100ppm of co for the predetermined period stored in the microcomputer. step 2: obtain v1 and v4 at the conclusion of stabilization. step 3: calculate ?(rs), k temp , ?(rs ? ) according to the procedure in section 2-3(a,b). the value f(rs ? ) is stored temporarily in the microcomputers ram. step 4: after ventilating the calibration gas, v3 is continuously monitored and converted to ?(rref) [ see equation in 2-3(c) ]. using a potentiometer (vradj), adjust ?(rref) to equal ?(rs ? ) in 100ppm of co which was memorized in step 3. this procedure can be simplified by directing the microcomputer to activate an led when ?(rref) is set to the correct level. for example: if ?(rref) = [?(rs ? )(100ppm)] 3%, then led turn on else led turn off main calibration revised 04/01 8 calibration of TGS2442 -1.4 -1.0 -0.6 012345 v7 (v) co concentration (ppm) alarm delay time (min.) 103.0 53.6 23.2 14.9 10.9 7.14 65 100 200 300 400 600 c(min) c(max) 5% cohb 10% cohb center (7.07% cohb) appendix - calibration at two or more concentrations detectors which display co concentration demand more accurate calculation of co concentrations. to obtain sufficient accuracy, calibration should be conducted at two or more co concentrations accord- ing to the signal processing procedures in section 2. for illustration, an example of 300ppm and 100ppm of co as calibration points is used in this section. the procedure of compensation according to b grade in section 3-2(b) may be omitted. instead, ?(rs ? ) of a second co concentration (300ppm in this case) is obtained by following steps 1~ 4 in section 3-3. by this procedure, the sensors b value can be obtained for each detector from the following equation: b = ?(rs ? )(300ppm) / ?(rs ? )(100ppm) in turn, this b value can be converted into an a value by using the equation shown in section 3-2(b). this a value ( a mem ) is temporarily stored in the ram of the microcomputer ( see sec. 2-3(d) ). to compensate for the slope of the sensitivity curve, a slope compensation circuit shown in figure 10a can be used. since the range of values for v7 is from 0 ~ 5v and the range of a values is from -1.4 ~ -0.6, a linear relationship between the v7 and a can be established (see figure 10b). then, in order to compensate for a value, the v7 port is used--adjust the potentiometer (vradj2) so that the a calb value is set as close to a mem as possible. this procedure can be simplified by directing the microcomputer to activate an led when a is set to the correct level: for example: if a calb = a mem 3%, then led turn on else led turn off following these procedures, each sensor can be fully compensated for temperature and sensitivity slope. 4. ability of sensor to meet performance standards this section will show how TGS2442, if used in the manner described in this document, can satisfy co detector performance standards such as ul2034 and the csa 6-96 standard. the following assumptions are made for this purpose: * no error exists in calibration gas concentration * no adjustment error in vradj exists * the gas sensitivity curve is linear on a logarithmic scale between 60-600ppm of co * no error exists in temperature compensation under these conditions, accuracy of calibration will depend upon the accuracy of ?(rs) and b . when calibration is done using two or more co concentrations (section 3-appendix), calibration without error can be done at the targeted gas concentration. however, if calibration is done only at one gas concentration and is based on one of the combinations of rs and b grades supplied for the sensor, since b falls within a range for each grade, verification that such variation in b falls within acceptable limits is required. 4-1 requirements of performance standard the most stringent performance standard (csa 6- 96) requires that an alarm be generated at not less than 5% cohb but less than 10% cohb. the specified co concentration and accumulation times figure 11 - alarm times permitted by performance standard figure 10a - slope compensation circuit vradj2 figure 10b - relationship of slope (a) to v7 a calb = .16(v7)-1.4 a calb revised 04/01 9 calibration of TGS2442 t n i o p t s e t ) m p p ( e g n a r n o i t a r t n e c n o c o c b b b b b e d a r g m p p 5 6 m p p 0 0 1 m p p 0 0 2 m p p 0 0 3 m p p 0 0 4 a0 . 9 6 - 6 . 0 60 0 14 2 2 - 1 8 18 5 3 - 7 5 20 0 5 - 9 2 3 b0 . 9 6 - 6 . 0 60 0 14 2 2 - 2 8 19 5 3 - 7 5 21 0 5 - 0 3 3 c0 . 9 6 - 6 . 0 60 0 14 2 2 - 2 8 19 5 3 - 8 5 22 0 5 - 0 3 3 d0 . 9 6 - 5 . 0 60 0 15 2 2 - 2 8 10 6 3 - 7 5 24 0 5 - 0 3 3 e1 . 9 6 - 4 . 0 60 0 15 2 2 - 1 8 12 6 3 - 7 5 27 0 5 - 9 2 3 f1 . 9 6 - 3 . 0 60 0 15 2 2 - 1 8 15 6 3 - 6 5 21 1 5 - 9 2 3 d r a d n a t s t n e m e r i u q e r 5 9 ~ 8 4 5 4 1 ~ 5 7 0 7 2 ~ 5 4 1 0 0 4 ~ 0 1 2 0 2 5 ~ 0 6 2 e m i t m r a l a t ( . c n o c n i ) s e t u n i m ) m p p ( n o i t a r t n e c n o c o c ) n i m ( c ) r e t n e c ( c ) x a m ( c t 5 6 3 0 1 =8 45 65 9 t 0 0 1 6 . 3 5 =5 70 0 15 4 1 t 0 0 2 2 . 3 2 =5 4 10 0 20 7 2 t 0 0 3 9 . 4 1 =0 1 20 0 30 0 4 t 0 0 4 9 . 0 1 =0 6 20 0 40 2 5 t 0 0 6 4 1 . 7 =0 0 40 0 60 0 8 for each concentration are spelled out by the standard. while the standard lists specific delay times allowed for each co concentration, to facilitate this discussion the permissible range of co concentrations at each specific delay time will be used. the maximum and minimum values of alarming time permitted by the standard for each co concentration are plotted on the chart shown in figure 11. the log center between these two curves (7.07% cohb) is also plotted. from these curves, the values of con- centration width allowed at each delay time can be determinedsee table 7 for a listing of these values. 4-2 estimation of calibration accuracy the variation in each b grade can be illustrated as in figure 12. the center line is based on the b center value which is given to each sensor grade. at the calibration point of 100ppm, the ?(rs ) value of each sensor would be the same (?(rs ) = 1.0). but at 60 and 600ppm, the ?(rs ) could vary as shown in the chart. at each concentration of co, the center ?(rs ) can be identified and the +/- range of ?(rs ) values can also be determined. if the maximum and minimum ?(rs ) values fall within the allowable ranges of the standard (table 7), then sensors calibrated at one co concentration could satisfy the requirements of the performance standards. table 8 shows maximum and minimum co concentrations for each sensor grade compared to the range of co concentrations permitted by performance standards. 4-3 conclusion as table 8 illustrates, properly calibrated TGS2442 sensors can satisfy the requirements of current table 7 - co concentration ranges vs. alarm times as specified by performance standard 0.1 1 10 10 100 1000 rs/ro co concentration (ppm) center min max calibration point c(min) c(max) figure 12 - variation of alarm concentrations in b grades (ro = rs at 100ppm co, 25?c/40%rh) table 8 - TGS2442 alarm concentrations vs. performance standard requirements performance standards even if calibrated with only one co concentration. this verification is based on the aforementioned assumptions. any factors which may influence these assumptions should be taken into consideration when planning actual detector design and when designing the calibration process. ?(rs )/?(ro) revised 04/01 10 calibration of TGS2442 appendix TGS2442 temperature compensation factors supplementary data e u l a v t u p n i 4 v ) c ? ( p m e t k p m e t t n e i c i f f e o c 5 1 . 40 1 -2 7 . 2 1 1 . 49 -4 6 . 2 6 0 . 48 -6 5 . 2 2 0 . 47 -9 4 . 2 7 9 . 36 -1 4 . 2 2 9 . 35 -4 3 . 2 7 8 . 34 -6 2 . 2 2 8 . 33 -9 1 . 2 7 7 . 32 -2 1 . 2 1 7 . 31 -6 0 . 2 6 6 . 309 9 . 1 0 6 . 313 9 . 1 4 5 . 327 8 . 1 9 4 . 331 8 . 1 3 4 . 346 7 . 1 7 3 . 350 7 . 1 1 3 . 365 6 . 1 5 2 . 370 6 . 1 9 1 . 385 5 . 1 3 1 . 391 5 . 1 6 0 . 30 16 4 . 1 0 0 . 31 12 4 . 1 4 9 . 22 18 3 . 1 8 8 . 23 14 3 . 1 1 8 . 24 10 3 . 1 5 7 . 25 17 2 . 1 9 6 . 26 14 2 . 1 3 6 . 27 10 2 . 1 6 5 . 28 17 1 . 1 0 5 . 29 14 1 . 1 4 4 . 20 22 1 . 1 8 3 . 21 29 0 . 1 2 3 . 22 27 0 . 1 6 2 . 23 24 0 . 1 0 2 . 24 22 0 . 1 4 1 . 25 20 0 . 1 e u l a v t u p n i 4 v ) c ? ( p m e t k p m e t t n e i c i f f e o c 9 0 . 26 20 8 9 . 0 3 0 . 27 21 6 9 . 0 7 9 . 18 23 4 9 . 0 2 9 . 19 26 2 9 . 0 6 8 . 10 39 0 9 . 0 1 8 . 11 34 9 8 . 0 6 7 . 12 39 7 8 . 0 1 7 . 13 35 6 8 . 0 6 6 . 14 32 5 8 . 0 1 6 . 15 39 3 8 . 0 6 5 . 16 37 2 8 . 0 2 5 . 17 36 1 8 . 0 7 4 . 18 35 0 8 . 0 3 4 . 19 35 9 7 . 0 8 3 . 10 46 8 7 . 0 4 3 . 11 46 7 7 . 0 0 3 . 12 48 6 7 . 0 6 2 . 13 49 5 7 . 0 2 2 . 14 42 5 7 . 0 8 1 . 15 44 4 7 . 0 4 1 . 16 47 3 7 . 0 1 1 . 17 40 3 7 . 0 7 0 . 18 44 2 7 . 0 4 0 . 19 48 1 7 . 0 1 0 . 10 52 1 7 . 0 5 7 9 . 01 56 0 7 . 0 4 4 9 . 02 51 0 7 . 0 4 1 9 . 03 56 9 6 . 0 5 8 8 . 04 52 9 6 . 0 7 5 8 . 05 57 8 6 . 0 0 3 8 . 06 53 8 6 . 0 3 0 8 . 07 59 7 6 . 0 8 7 7 . 08 55 7 6 . 0 3 5 7 . 09 51 7 6 . 0 9 2 7 . 00 68 6 6 . 0 0.1 1 10 -100 102030405060 ktemp temperature (?c) |
Price & Availability of TGS2442
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |