  modstack tm datasheet: 2b6i 500/800-350w preliminary data 2B6I500-800-350W.doc 1 of 10 2003-11-11 key data 2 x 3 x 350a ac at 500v ac, watercooled general information stack with igbt, heatsinks, capac itors, drivers and sensors for several inverter applications. these are only technical data! please read h eedful the complete documentation and attend the adopted design environment! especially the emc environment and the controller functionality. topology dc link + 2b6i load type resistive, inductive load cooling by water targed application industrial drive extra available in master [m] or slave [s] configuration drivercore scale driver monitors current-, voltage-, temperature-monitoring module (unit1) n.a. module (unit2) igbt 6x ff600r12kl4c interface electrica l, opt. optical standards en50178, ul94, prepared for ul508c product id (eupec) 25535 master 25536 slave drawing no. 38000002_b_mb circuit diagram no. 57000002 unit 1 unit 2 ? ? = = signal conditioner & monitor driver interface b6i dc link ? ? = driver b6i electrical data parameter min typ max assumed linevoltage for isolation- management v line 500 v rms dc link voltage v dc 675 880 v av dc link overvoltage shutdown within 100s v dcmax v dc link current at i unit2, v unit2, cos_ ? unit2 i dclink input 868 a av voltage unit1 v unit1 - v rms continious current unit1 ? = ? air_inlet i unit1 - a rms shorttime current unit1 10s, every 180s, initial load = i unit1 i unit1_10 - a rms pulse current unit1 sinehalfwave 20ms - a peak
modstack tm datasheet: 2b6i 500/800-350w preliminary data 2B6I500-800-350W.doc 2 of 10 2003-11-11 dc current at unit1 no rotating field, ? = ? air_inlet, i unit1_dc - a av overcurrent shutdown unit1 percentage of i unit1. within 15s - % switching freq. unit1 f sw1 - hz power losses unit1 v = v unit1_min, i = i unit1, fsw=fsw1 p loss1 - w voltage unit2 depending on controller v unit2 500 v rms displacement factor cos_ ? unit2 -0,9 +0,9 continious current unit2 ? = ? water_inlet, ? chip <= 125c f unit2>5hz both b6i separated i unit2 2x3x 350 a rms shorttime current unit2 ? water_inlet<=40c, 10s, every 180s, initial load = i unit2 i unit2_10 2x3x 420 a rms pulse current unit2 sinehalfwave 20ms, starting from i unit2. i unit2peak - a peak dc current at unit2 no rotating field, ? = ? air_inlet, i unit2_dc 0,4* i unit2 a dc overcurrent shutdown unit2 percentage of i unit2. within 15s 125 % switching freq. unit2 f sw2 3000 hz power losses unit2 i= i unit2, f sw= f sw2 p loss2 6400 w power losses (pcb and capacitor) p loss_aux 250 w r filter - ohm filterresistors at output unit2 applicable for sinewavefilters (damping, optionally) p rfilter - watt auxiliary voltage v aux 18 24 30 v av auxiliary power demand v aux=24 v av, to feed with b6u p aux 80 w power v burst 2 kv control v burst 1 emc test according en61800-3 at named interfaces aux (24v) v surge 1 kv insulation test voltage according en50178 f=50hz, t=1min v isol 1,8 kv rms important component data dc link capacitor c dc 18,8 mf dc link capacitor type elcap loadcycle for: wind lt d - year capacitor design lifetime loadcycle for: solar lt d - year
modstack tm datasheet: 2b6i 500/800-350w preliminary data 2B6I500-800-350W.doc 3 of 10 2003-11-11 (eupec approximation) loadcycle for: industrial drive ( ? air=35c, i=0,8, duration=24h/day) lt d 6 year requirements to the powersource assumed inductance of feeding powersource (necessary inductance not included, feeded by b6u) l feed 90 h fan data (assumed when excluded) fan type assumed - fan voltage v fan - v rms fan frequency f fan - hz fan current i fan - a rms fan air pressure assumed ? p airfan - pa controller interface data driver see datasheets pcb tr10x master (only first b6i) sad101 slave paralleling interface see datasheet pcb - master (only first b6i) (optionally) oea101 slave optical interface see datasheet pcb - digital input level resistor to gnd (1,8k) high = on min 15ma v in 0 15 v digital output level open collector low = ok max 15ma v out 0 15 v analog current outputs unit1 load max 1ma at i unit1 4 v analog current outputs unit2 load max 1ma at i unit2 4 v analog dc link voltage output load max 1 ma at v dcmax v dcout 9 v analog temperature out load max 1ma at ? j=125c v ? out 9 v optical input level optionally 12 w optical output level optionally 60 w requirements to the controller emc protection according en61800-3 at auxiliary power and controlinterface 1 kv
modstack tm datasheet: 2b6i 500/800-350w preliminary data 2B6I500-800-350W.doc 4 of 10 2003-11-11 emc environment shieldconcept with te (true earth) separated from pe, hf conform installation drive pulse time t on_min 10 s blockout time t pause 10 s overvoltage shut down reaction time after overvoltage message by powerstack interface 50 s overcurrent shut down reaction time after overcurrent message by powerstack interface 10 s mechanical data airvelocity v air - m/s airflow heatsink d v /d tair - m3/h air pressure drop heatsink ? air=20c p air=1013 hpa dry- and dustfree, measured outside of heatsink. according din 41882 ? pair - pa waterflow heatsink d v/ d t water 12 l/min water pressure drop heatsink max. water pressure according coolingwater specification from eupec for copper tubes ? pw ater 200 8 mbar bar water connection (tube diameter) ?? inch dimensions width x depth x hight 1090 596 250 mm mass approximation 101 kg storage temperature range ? stor -40 +65 c operating temperature range (pcb and capacitor) minimal 0 c for optional optical interface ? op -25 (0) +55 c - cooling air inlet temperature (heatsink) heatsink temperature > -25c ? air_inlet - - c cooling water inlet temperature (heatsink) ? water_ inlet -25 +40 c cooling airvelocity (pcb and capacitor) v air_pcb 2 m/s air pressure standard atmosphere p air 900 1100 hpa humidity no condensation rel. h 0 95 % installation height 0 1000 m vibration en60068-2-6, fc 10 m/s2
modstack tm datasheet: 2b6i 500/800-350w preliminary data 2B6I500-800-350W.doc 5 of 10 2003-11-11 10..59hz 0,075mm permanence vibration en60068-2-6, fc 10-150hz, 20 cycles 20 m/s2 shock en60068-2-27, ea halfsine 11ms, 3 pulses 100 m/s2 protection degree ip00 pollution degree 2 overvoltage category iii
modstack tm datasheet: 2b6i 500/800-350w preliminary data 2B6I500-800-350W.doc 6 of 10 2003-11-11 derating curves (igbt part) current derating at low rota ting field frequency (f0). maximal 100% current is allowed. cos(phi) = -0.64, (generator) theta_air = 40c 0 20 40 60 80 100 120 -5 0 5 10 15 20 25 30 35 40 45 50 55 f0 [hz] i/i_nom [%] cos(phi) = 0.64, (motor) theta_air = 40c 0 20 40 60 80 100 120 -5 0 5 10 15 20 25 30 35 40 45 50 55 f0 [hz] i/i_nom [%]
modstack tm datasheet: 2b6i 500/800-350w preliminary data 2B6I500-800-350W.doc 7 of 10 2003-11-11 current derating at different switching freque ncies. see datatable for nominal switching frequency. in this drawing 2500hz ist assumed. maximal 100% current is allowed. igbt, cos(phi) = 0.64 theta_air = 40c 0 20 40 60 80 100 120 140 160 180 0 1000 2000 3000 4000 5000 6000 7000 fsw [hz] i/i_nom [%] ff 400 r12 kl4c ff 800 r17 kf6cb2 ff 1200 r17 ke3 diode, cos(phi) = 0.64 theta_air = 40c 0 20 40 60 80 100 120 140 160 180 200 0 1000 2000 3000 4000 5000 6000 7000 fsw [hz] i/i_nom [%] ff 400 r12 kl4c ff 800 r17 kf6cb2 ff 1200 r17 ke3
modstack tm datasheet: 2b6i 500/800-350w preliminary data 2B6I500-800-350W.doc 8 of 10 2003-11-11 igbt, cos(phi) = - 0.64 theta_air = 40c 0 20 40 60 80 100 120 140 160 180 0 1000 2000 3000 4000 5000 6000 7000 fsw [hz] i/i_nom [%] ff 400 r12 kl4c ff 800 r17 kf6cb2 ff 1200 r17 ke3 diode, cos(phi) = -0.64 theta_air = 40c 0 20 40 60 80 100 120 140 160 180 0 1000 2000 3000 4000 5000 6000 7000 fsw [hz] i/i_nom [%] ff 400 r12 kl4c ff 800 r17 kf6cb2 ff 1200 r17 ke3
modstack tm datasheet: 2b6i 500/800-350w preliminary data 2B6I500-800-350W.doc 9 of 10 2003-11-11 miscellaneous this technical information specifies semiconducto r stacks but promises no characteristics. it is valid in combination with the belonging technical notes. this document may be cha nged without prior notice. warning! prior to installation and commissioning all safety notices and warnings and all warning signs attached to the equipment have to be carefully read. make sure that all warning signs remain in a legible condition and missing or damaged signs are replaced. the safety instructions have to be strictly adhered to. the manual contains detailed information on all technical topics with regard to the eupec powerstack. for further details regarding p ublications of the eupec powerstack and information on other publicati ons in the area of powersta cks please contact your nearest eupec branch or visit our we bsite: http://www.eupec.com. eupec gmbh 2003. all rights reserved prepared by j.schiele 2003-11- 11 date of publication approved h.nbel by 2003-11-11 revision 1
powerstack 2b6i 500/800-350w, drawing, preliminary data 2B6I500-800-350W.doc 10 of 10 2003-03-17


▲Up To Search▲   

 
Price & Availability of 2B6I500-800-350W

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X