|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
Bussmann(R) TRON(R) In-Line Fuseholders Single-Pole for Solid Neutral HET Series Catalog and Specification Data - Non-Breakaway Conductor Terminals Stranded No. Per Terminal Terminal Type Conductors Size Catalog Symbol Load & Line (2 & 3) A B Copper Crimp Non-Breakaway Holders Catalog Symbol: HET-AA, HET-AB, HET-BB, HET-JJ, and HET-JK In-Line Fuseholders, Single-Pole Water-Resistant For breakaway holders, see page 2 HET -- A HEB fuseholder with a permanently installed solid neutral. Easily identified by white plastic coupling nut. Example: A single-pole, in-line holder for a neutral is required. One solid copper #8 is on the load side, copper crimp for connection. A solid copper #6 is on the line side, and a copper crimp is required. 1. Choose HET- series. 2. Choose "A" for load side. 3. Choose "B" for line side. Complete Catalog Number: HET-AB. #12 to #8 #12 #10 #6 #4 1 2 2 1 1 Solid * * * * * * * * * * * * Copper Set-Screw #12 to #3 #12 to #2 Aluminum Set-Screw #12 to #2 1 * * L 1 2 * * J K Catalog Data -- Insulating Boots Catalog Numbers 2A0660 2A0661 Type Single Conductor Two Conductor Ordering Information: HET Load Terminal Line Terminal Insulating boots are not included with non-breakaway parts and must be ordered separately. They come standard with the breakaway series. The HET-AW & HET-JW do not have the boots. These catalog items do not have a breakaway receptacle. When boots are utilized, extra heat retention requires that fuses are sized at a minimum of 200% of the RMS load current. Recommended Torque on Coupling Nut: 10-20 in-lb. 7-16-03 N03082 Form No. HET Series Page 1 of 2 Data Sheet: 2125 Bussmann(R) TRON(R) In-Line Fuseholders Single-Pole for Solid Neutral Breakaway Holders Catalog Symbol: HET-AW-RLC-A, HET-AW-RLC-B, HET-AW-RLC-C, HET-AW-RLC-J, HET-AW-RYC, HET-BW-RLC-B, HET-BW-RYC, HET-JW, HET-JW-RLC-J, HET-JW-RYC, and HET-AW In-Line Fuseholders, Single-Pole Example: A single-pole, in-line, breakaway holder for a neutral is requested. A single #10 solid, copper crimp is on the load side. A single #10, solid wire and a copper crimp is needed on the line side. 1. Choose HET- series. 2. Choose "A" from 1st page for load side. 3. Choose "W" for breakaway requirement. 4. Choose "RLC-A" for breakaway receptacle on line side. Complete Catalog Number: HET-AW-RLC-A Catalog and Specification Data Breakaway Receptacles HET Series Copper Crimp #12 to #8 #6 #4 1 1 1 * * * Stranded * * * * * No. Per Terminal Terminal Type Conductor Data Size Catalog Symbol Line Terminal (3) -RLC-A -RLC-B -RLC-C Copper Set-Screw #12 to #3 1 Solid * -RLC-J #12 to #3 2 * -RYC Solid Breakaway (Required with breakaway Receptacle) W Ordering Information: HET Load Terminal W Line Terminal Recommended Torque on Coupling Nut: 10-20 in-lb. The only controlled copy of this Data Sheet is the electronic read-only version located on the Bussmann Network Drive. All other copies of this document are by definition uncontrolled. This bulletin is intended to clearly present comprehensive product data and provide technical information that will help the end user with design applications. Bussmann reserves the right, without notice, to change design or construction of any products and to discontinue or limit distribution of any products. Bussmann also reserves the right to change or update, without notice, any technical information contained in this bulletin. Once a product has been selected, it should be tested by the user in all possible applications. 7-16-03 N03082 Form No. HET Series Page 2 of 2 Data Sheet: 2125 |
Price & Availability of HET-AW-RLC-C |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |