Part Number Hot Search : 
B102S TIC206N XBNXXX 48102SC CDB391A TBYV26C 1N4461US 1N5143A
Product Description
Full Text Search
 

To Download W172DIP-147 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 Magnecraft
Struthers-Dunn
DESCRIPTION
PRODUCT INDEX
PAGE 1 & 2, DOCUMENT 100
PAGE
INSIDE FRONT COVER 3 4-7
DOCUMENT #
340 341 115
CLASS TO CLASS CROSS REFERENCE GUIDE STOCKING DISTRIBUTORS, SALES REPRESENTATIVES & AGENTS
SECTION 1
W78 W67 A314/W250 284 W388/283 W388/283 W389 W389 W97 219 RSX-1800 W21 W88HP
SELECTOR GUIDE
1, 3, 5, 10 & 15 Amp, P.C. and Solder/Plug-in 3, 5 Amp, P.C. and Solder/Plug-in 10 Amp, Octal Plug-in 10 Amp, Solder Plug-in General Specifications 11 to 15 Amp, Solder Plug-in and Flange mount General Specifications & Ratings 30 Amps, Flange Mount 25 Amp, Plug-in and Side Stud mounting 10 Amp, Pin Base Plug-in 5 Amps, Pin Base Plug-in 30 Amps, Plug-in with Polarizing Pin. 10 AMP, Octal Plug-in, Hermetically Sealed
Socket Compatible and General Purpose Relays - 1 to 30 Amperes
8 - 12 13 - 15 16 - 18 19, 20 21, 22 23 - 25 26 - 28 29, 30 31, 32 33, 34 35, 36 37 38 39 - 43 116 117 118 120 119 119 121 121 122 123 124 125 126 342
SECTION 2
276 W90 W91 W9A W92 W7 W60 W178 W49 W76 W1330 & W1335
SELECTOR GUIDE
Printed Circuit Board Relays - 1 to 30 Amperes
7 & 10 Amp, Subminiature 30 Amp Miniature 30 Amp, P.C. and Flange mount 30 Amp, P.C.and Flange mount 30 Amp, P.C.and Flange mount 2 Amp, Subminiature 2 AMP, Miniature 5 & 10 AMP, Miniature 3, 5 & 10 AMP, P.C.and Flange Mount 10 & 16 AMP, Miniature 5 Amp, Miniature 44 45, 46 47, 48 49, 50 51, 52 53, 54 55, 56 57, 58 59, 60 61, 62 63 64 - 67 109 102 103 104 105 106 107 112 113 114 108 127
SECTION 3
REED W117 W107, W171, W172 W171 MRRDL W172 W101, W104, W131,W134,W193 W101, W131 W104 W134 W193 MR-Y MRR & RR RRN W102 W120
SELECTOR GUIDE
Application Data SIP, 0.5 Amp, 4 pin, SPST-NO or NC DIP, 0.5 Amp, 8 pin, SPST-NO Specifications DIP, 0.5 Amp, 8 pin, 1 & 2 pole-NO or NC DIP, 0.5 Amp, Dual Coil Latch, SPST-N.O. DIP. 0.5 - 1.0 Amp, SPDT, DPDT General Specifications Miniature, 0.5 Amp, 1 to 3 pole NO & Latching Miniature, 2 Amp, 1 & 2 pole NO Mercury Miniature, 0.25 Amp,SPDT, DPDT Miniature, 1.0 Amp, SPDT, DPDT Mercury Miniature, 0.5 Amp, up to 6 pole NO or 4PDT. Miniature, 0.5 Amp, with End Terminals Axial Lead, Shielded, 0.5 Amp, Open Style Metal Cover/Shield, Open Style Metal Cover/Shield Coxial R.F. switching
Reed Relays for P.C. Board Applications - 3 VA to 100 VA
68, 69 70 71 72 73 74 74, 75 76 77 78 79 80 81, 82 83, 84 85, 86 87, 88 89 90 91 - 93 343 128 129 130 130 131 131 132 133 133 134 134 135 136 137 139 138 344 140
SECTION 4
Solid State Relays W226, W230, W231 W226 W230 W231 W6 W6 W301T W6
SELECTOR GUIDE
Application Data General Specifications Miniature ,7 Amp, P.C. or Push-on Terminals Miniature, 1.5 or 3 Amp. P.C Terminals Miniature, 4 Amp, Spade Terminals, Flange mount General Specifications 2.5 to 75 Amp. Screw Terminals Opto Isolator, axial Lead Embossed Safety Cover
Solid State Relays - 2 to 75 Amperes
94 - 95 96 97, 98 99, 100 101 102, 103 104 - 107 108 108 345 141 142 143 144 145 146 147 147
PAGE 1
WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
DESCRIPTION
PAGE
109 - 112
DOCUMENT #
148
SECTION 5
Time Delay Relays and Sensors
Time Delay Relays W211 W211PROG W67 W222 W388 286/287 326, 327 236, 237 & 238 246, 247 W235 349 W236
SELECTOR GUIDE
Application Data Octal Style, 10 Amp Octal Style ,Programmable, 10 Amp, Miniature, 5 Amp Repeat Cycle, 10 Amps, Square base, 12Amp,Solder/plug-in or Flange 1 - 3 pole, 10 Amps, Solder/Plug-in, flange panel screw. Octal 1 -3 Pole, 10 Amp, Industrial Plug-in with Locking Clip. 10 Amps, Industrial Plug-in with Locking Clip. 10 Amps, Current Sensor, 10 Amps, Plug-in or Screw panel mount Voltage Sensor, 10 Amps, up to 400 HZ 1-3 Phase Voltage Sensor, 10-13 Amps, Solder/Plug-in or Octal
113, 114 115, 116 117 118 119 120 - 124 125, 126 127, 128 129 - 130 131 132 133 134, 135 136 - 139
149 151 150 152 153 154 346 347 348 157 158 159 160 161
SECTION 6
W199 425 W88UKD 415 275 575 101, 102, 103 214 MDR MDR 102, 103
SELECTOR GUIDE
Open Style, 30 Amp , SPDT Open Style, 30 Amp Power Relay up to 3 pole Miniature Open Style, 30 Amp, SPST-NO DM Open Style, 15 Amp, 1 & 2 Pole. Motor Reversing Contactor, 15 Amp, 3 Pole Motor Reversing Contactor, 30 Amp, 6 Pole Solenoid Style Contactor, SPST-DM, 50 to 200 Amps Ground Fault Interrupt (GFI), 20 Amp, DPDT General Specifications & Application Data Mercury Displacement relays 30 to 100 Amp Solinoid Style Lighting Contactor 100 & 200 Amps
Relays and Contactors - 15 to 200 Amperes
140 - 146 147 148 149, 150 151, 152 153, 154 155, 156 157 158, 159 160 - 164 165 166 - 168 162 163 170 171 166 167 168 169 164 165 349 172
SECTION 7
Sequence & Latching W250ML W388ML/285 308 B255 W88L 311 C85
SELECTOR GUIDE
Latching, Sequence and Stepper Relays
Application Data Octal Base, Magnetic Latching, 10 Amps Latching, 10 Amp, Solder/Plug-in Latching, 10 Amp, 4 Pole. Solder/Plug-in Mechanical Latch, 10 Amps, Pin base Plug-in Open or Enclosed Mechanical Latch,10 Amp Plug-in Sequence (Stepper), 5 Amp Open Style, Sequence (Stepper) 20 Amp 169 170 171, 172 173, 174 175, 176 177, 178 179 180 181, 182 350 177 173 174 175 176 179 180 181
SECTION 8
158 102HV
SELECTOR GUIDE
Open Style, 200 mA, 5000Vdc Encapsulated Reed, 10-30mA, up to 10kv
Hi- Voltage Relays - 2,500 to 10,000 Volts
183 184 185, 186 182 183 184 185 351 186 187 188 189 191 191 192 193 197 196 190 195 195
SECTION 9
Sensitive Relays, Low Input Power
112, 112PGF 67S 392 292
SELECTOR GUIDE
Low Power, 2 Amps, Pin Base Plug-in w/ locking clip Miniature Sensitive, 3 Amps, 2 - 6 Poles. Sensitive, Octal Plug-in, 5 Amps, 1 - 3 Poles Solder/plug-in, 5 Amps, 1 - 3 Poles
187, 188 189 190 191 192 - 194
SECTION 10
Sockets and Accessories
70--464-1, 70-465-1 70-459-1, 70-461-1 70-378-1, 70-401-1, 70-379-1, 70-402-1, 70-463-1 70-124-1 & -2, 70-178-1 & -2 27390, 33377 70-475, 70-478 70-303-1 THRU 70-310-1 70-312 70-276
SELECTOR GUIDE
Series A314/250, 8 & 11 Pin Octal, Panel/DIN mount CLASS 78 Panel/DIN mount Class 78, Chassis, P.C., Class 388/283 Style, Panel/DIN Mount Class 388/283 Style, Chassis Mount or P.C. Series 219 style, Panel mount, screw terminal Class 76 Style, Panel/DIN mount Class 67 chassis mount Class 97 Style, Chassis mount DIP Style, 14 Pin
195 196 197, 198 199 200 201 202 203, 204 205 205
SECTION 11
CE Customer Service Staff
UTILIZATION CATAGORIES
Utilization Categories Staff Directory
206 207 INSIDE BACK COVER
199 198
WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
PAGE 2
Magnecraft
Struthers-Dunn
FAX ON DEMAND DIRECTORY
@ STOCKING DISTRIBUTORS. @ FACTORY DIRECT FIELD SALES PROFESSIONALS. @ U.S. AND INTERNATIONAL AGENTS.
PLEASE DIAL 800-891-2957
FOR AN UP-TO-DATE DIRECTORY FOR YOUR AREA. WHEN PROMPTED, PLEASE ENTER THE APPROPRIATE DOCUMENT NUMBER FROM THE MAP BELOW.
DOCUMENT NUMBER OUTSIDE THE U.S. & CANADA:
352
CANADA DOCUMENT NUMBER:
353
370 354 356 365 355 361 368 364 357 358 362 363 366 367 359 360 369
UNITED STATES DOCUMENT NUMBERS SHOWN INSIDE THE STATES.
PAGE 3
WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
SECTION
1
1
SOCKET COMPATIBLE AND FLANGE MOUNTED GENERAL PURPOSE RELAYS 2 TO 30 AMPERES Page 4
Magnecraft
Struthers-Dunn
SOCKET COMPATIBLE
RELAY SERIES 78 67 A314/250
SEE SECTION 10 FOR MATING SOCKETS
QUALIFIED
ISO 9002 QS 9000
ISO 9002 QS 9000 POLYCARBONATE DUST COVER. POLYCARBONATE DUST COVER
FEATURES
POLYCARBONATE DUST COVER SOLDER/PLUG-IN OR PC BOARD MOUNTING.
SOLDER/PLUG-IN OR PC BOARD 8 OR 11 PIN OCTAL PLUG-IN MOUNTING INDUSTRY STANDARD FOOTINDUSTRY STANDARD FOOTPRINTS. INDUSTRY STANDARD FOOTPRINTS UP TO 4 POLES WITH STANDARD OR PRINTS. INDICATOR LAMP AND PUSH BIFURCATED CONTACTS, INDICATOR UP TO 8 POLES WITH STANDARD BUTTON AVAILABLE. LAMP AND PUSH BUTTON, OR BIFURCATED CONTACTS. TOP FLANGE COVER , PANEL/DIN, PANEL/DIN STYLE SOCKETS CHASSIS OR P.C STYLE SOCKETS CHASSIS OR PC STYLE AVAILABLE. AVAILABLE. SOCKETS AVAILABLE.
CONTACT DATA
CONTACT
CONFIGURATION:
SPDT, DPDT 15 &10 AMPS AT 120/240 VAC
4PDT 1, 3 & 5 AMPS AT 120/240 VAC
SPDT TO 8PDT STANDARD CONTACTS 5 AMP BIFURCATED CONTACTS 3 AMP AT 120VAC/32VDC
SPDT
DPDT
3PDT
MAXIMUM ALLOWABLE CONTACT LOAD:
12 12 10 AMPS AMPS AMPS AT AT AT 120 VAC 120 VAC 240 VAC
CONTACT CONTACT
MATERIAL: RESISTANCE:
SILVER, GOLD PLATED - 1A SILVER, GOLD OVERLAY SILVER, GOLD FLASHED - 3A SILVER CADMIUM OXIDE - 5, 10 & 15A 50 MILLIOHMS (INITIAL) 50 & 100 MILLIOHMS MAX
SILVER CADMIUM OXIDE, ( GOLD FLASHED) 50 MILLIOHMS (INITIAL)
INSULATION CHARACTERISTICS
DIELECTRIC STRENGTH 1500 V rms 6, 12, 24,120 & 240 VAC 6, 12, 24, 48 & 110 VDC 1.2 VA 0.9 WATTS 1500 V rms 120 VAC 5, 12, 24, 48 &115 VDC 2.5 VA 2 WATTS 1500 V rms 24, 120 & 240 VAC 12, & 24 VDC 2.75 VA 1.2 WATTS
COIL DATA
AC - VOLTAGE: DC - VOLTAGE: POWER: VA,: (VAC) WATTS,: (VDC)
GENERAL DATA
AMBIENT TEMPERATURE OPERATIONAL: STORAGE: TIMING VALUES MAX. OPERATE: MAX. RELEASE: LIFE MECHANICAL: ELECTRICAL: - 40 C to + 70 C - 55 C to + 70 C - 55C to + 105C 18 MILLISECONDS 8 MILLISECONDS 10 MILLION OPERATIONS 100,000 OPERATIONS H W L 1.20 X .735 X - 10 C to + 50 C (AC) - 10 C to + 60 C (DC) - 30 C to + 105 C 25 MILLISECONDS 20 MILLISECONDS 10 MILLION OPERATIONS 100,000 OPERATIONS H W L 1.37 X 1.37 X 2.25 C US
25 MILLISECONDS 25 MILLISECONDS AC- 50M, - DC-100M OPER'S. 200,000 OPERATIONS . H W L
DIMENSIONS APPROVALS PAGE NUMBER PAGE 5
C
.858 X 1.10 X 1.40 US
PAGE 8 THRU 12
PAGE 13 THRU 15
PAGE 16 THRU 18
WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
Magnecraft
Struthers-Dunn
SOCKET COMPATIBLE & FLANGE MOUNT
284 388 & 283
QUALIFIED
389
QUALIFIED
97
ISO 9002 QS 9000 POLYCARBONATE DUST COVER. POLYCARBONATE DUST COVER.
ISO 9002 QS 9000 POLYCARBONATE FLANGED DUST COVER. 1/4" Q.C./SOLDER LUG TERMINALS FOR QUICK CONNECT. INDUSTRY STANDARD FOOTPRINTS TOP FLANGE COVER AVAILABLE. SPDT, DPDT SPDT-NO-NC (DM-DB) METAL DUST COVER 1/4" BRASS CONTACT TERMINALS
3/16" SOLDER/PLUG-IN, OR PC BOARD MOUNTING INDUSTRY STANDARD FOOTPRINT. CAPABLE OF SWITCHING UP TO 30 AMPS. WIDE CHOICE OF OPTIONS.
3/16" SOLDER/PLUG-IN, FLANGE OR PC BOARD MOUNTING INDUSTRY STANDARD FOOTPRINTS. WIDE SELECTION OFPANEL/DIN, CHASSIS & P.C. STYLE SOCKETS 15 AMP VERSIONS & TOP FLANGE COVERS AVAILABLE.
DPDT-NO-NC (DM-DB) CONTACTS CHOICE OF MOUNTING MATING SOCKETS
4PDT MAX TOTAL LOAD 30 AMPS @ 120 VAC, 20 AMPS @ 240 VAC 10 AMPS PER POLE NOT TO EXCEED 30 AMPS SILVER CADMIUM OXIDE, SILVER OR GOLD DIFFUSED 50 MILLIOHMS (INITIAL)
SPDT 13 AMPS AT 240 VAC
DPDT 12 AMPS AT 240 VAC
3PDT 11 AMPS AT 240 VAC
DPDT NO-NC (DM-DB) 25 AMPS @ 120 VAC/28VDC TUNG. LAMP 25A, 120VAC
25 AMPS @ 30 AMPS @ 300 VAC 300 VAC 3PDT 20 AMPS @ 150 VAC SILVER CADMIUM OXIDE 50 MILLIOHMS (INITIAL)
388B STYLES RATED UP TO 10 AMPS AT 150 VDC. SILVER CADMIUM OXIDE, ( GOLD FLASHED) 50 MILLIOHMS (INITIAL)
SILVER ALLOY 50 MILLIOHMS, (INITIAL)
1500 V rms 6, 12, 24, 48, 120 & 240 VAC 6, 12, 24, 48, 115-125 VDC 3.4 VA 1.9 WATTS
2000 V rms 24, 120 & 240 VAC 12, 24 & 120 VDC 2.75 VA 1.2 WATTS
2200 V rms 24, 120 & 240 VAC 12, & 24 VDC 3.5 VA 1.44 WATTS
2000 V rms 24, 120 & 240 VAC 12, 24 & 120 VDC 8 VA 3 WATTS
- 45 C to + 45 C (AC, COVR..) - 45 C to + 70 C (DC, COVR) - 45 C to + 85 C (DC, OPEN) 15 MILLISECONDS 10 MILLISECONDS 10 MILLION OPERATIONS 100,000 OPERATIONS H W L
- 30 C to + 50 C (AC) - 30 C to + 65 C (DC) - 30 C to + 100 C 24 MILLISECONDS 30 MILLISECONDS 5 MILLION OPERATIONS 100,000 OPERATIONS H W L
- 30 C to + 50 C (AC) - 30 C to + 65 C (DC) - 30 C to + 100 C 20 MILLISECONDS 20 MILLISECONDS 5 MILLION OPERATIONS 100,000 OPERATIONS H W L
- 20 C to + 50 C
35 MILLISECONDS 35 MILLISECONDS
5 MILLION OPERATIONS 100,000 OPERATIONS H W L
1.50 X 1.93 X 1.87
1.40 X 1.53 X 1.90 C US
1.40 X 1.53 X 1.90 C US
1.56 X 1.56 X 2.06
PAGE 19, 20
PAGE 21 THRU 25
PAGE 26 THRU 30
PAGE 31, 32 PAGE 6
WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
Magnecraft
Struthers-Dunn
SOCKET COMPATIBLE
RELAY SERIES 219 RSX-1800 21 88HP
SEE SECTION 10 FOR MATING SOCKETS
FEATURES
POLYCARBONATE DUST COVER 12 OR 14 PIN STYLES ENCAPSULATED COIL WIDE CHOICE OF CONTACT COMBINATIONS. LARGE CHOICE OF OPTIONS MATING SOCKETS AVAILABLE
POLYCARBONATE DUST COVER 12 PIN STYLES PERFORMS BASIC FUNCTIONS OF AN ALARM POINT OPERATES FROM AN N.O. OR N.C. TROUBLE CONTACT MATING SOCKETS AVAILABLE
POLYCARBONATE DUST COVER MEETS NEMA STD. TS 21992 APPROVED BY D.O.T INDUSTRY STANDARD FOOTPRINT
HERMETICALLY SEALED STEEL ENCLOSURE 10 AMP AND 12 AMP CONTACTS 8 OR 11 PIN OCTAL BASE.
CONTACT DATA
CONTACT CONFIGURATION: MAXIMUM ALLOWABLE CONTACT LOAD:
VARIOUS COMBINATIONS 10 AMPS @ 240 VAC/28 VDC
2 PAIR of DPDT or 3PDT 10 AMPS @ 120VAC, 28 VDC
DPDT 20 AMPS @ 120/240 VAC, 28 VDC 20 AMPS, 120VAC TUNGSTEN
DPDT, 3PDT (2 POLE) 12 AMPS @ 120VAC 8 AMPS @ 240 VAC (3 POLE) 10 AMPS @ 120VAC 6 AMPS @ 240 VAC SILVER CADMIUM OXIDE 50 MILLIOHMS (INITIAL)
Available with Make Before Break contacts CONTACT CONTACT MATERIAL: RESISTANCE: SILVER CADMIUM OXIDE, GOLD DIFFUSED 50 MILLIOHMS (INITIAL) SILVER CADMIUM OXIDE 50 MILLIOHMS (INITIAL) SILVER ALLOY 100 MILLIOHMS (INITIAL)
INSULATION CHARACTERISTICS
DIELECTRIC STRENGTH 1500 V rms 6, 12, 24, 120 & 240 AC 6,12, 24(28),32,115(125)DC 5 VA 1.8 WATTS 1500 V rms 6, 12, 24 & 120 VAC 6, 12, 24 & 110-125 VDC 5 VA 1.8 WATTS 1500 V rms 1500 V rms
COIL DATA
AC - VOLTAGE: DC - VOLTAGE: POWER: VA,: (VAC) WATTS,: (VDC) 120 VAC OPTIONAL VDC 4 & 8 VA 120 VAC 12, 24 VDC 3.0 VA 1.5 WATTS
GENERAL DATA
AMBIENT TEMPERATURE OPERATIONAL: STORAGE: TIMING VALUES MAX. OPERATE: MAX. RELEASE: LIFE MECHANICAL: ELECTRICAL: - 10 C to + 60 C - 10 C to + 70 C - 40 C to + 84 C
- 10C to + 50C (AC), - 10C to + 60C (DC), -30C to + 105C
25 MILLISECONDS 20 MILLISECONDS 20 MILLION OPERATIONS 100,000 OPERATIONS H W L .2.62 X 1.468 X .2.593
25 MILLISECONDS 20 MILLISECONDS 20 MILLION OPERATIONS 500,000 OPERATIONS H W L .2.62 X 1.468 X 2.593
25 MILLISECONDS 25 MILLISECONDS 5 MILLION OPERATIONS 250,000 OPERATIONS H W L .2.47 X 1.85 X 2.84 C US
25 MILLISECONDS 20 MILLISECONDS 5 MILLION OPERATIONS 100,000 OPERATIONS H W L
DIMENSIONS APPROVALS PAGE NUMBER PAGE 7
1.53 X 1.53X 2.03
PAGE 33, 34
PAGE 35, 36
PAGE 37
PAGE 38
WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
ICE CUBE STYLE SOLDER/PLUG-IN OR PC BOARD RELAY
CLASS
78
W78ACSX & CSX 4PDT, SOLDER/PLUG-IN 1, 3 OR 5 AMP
W78APCX & PCX 4PDT, PRINTED CIRCUIT 1, 3 OR 5 AMP
W78ARCSX & RCSX SPDT, DPDT, SOLDER/PLUG-IN 10 OR 15 AMP
Recognized Component mark for Canada and the United States.
W78ARPCX & RPCX SPDT, DPDT, SOLDER/PLUG-IN 10 OR 15 AMP
MANUFACTURED UNDER QUALITY SYSTEM
ISO 9002 & QS 9000
UL Recognized File No. E52197
C
US
*
COMPLIES WITH REQUIREMENTS OF IEC STANDARDS 947-4-1 AND 947-5-1 LOW VOLTAGE DIRECTIVE
COIL Pull-in Voltage: Dropout: Max. Voltage: Coil Resistance: Coil Insulation: Maximum tolerable coil dissipation: Duty: CONTACTS Contact Configurations: Contact Material: Contact Resistance: Contact Rating:
SPECIFICATIONS CLASS 78
75% of Nominal Voltage or less for DC, 80% of nominal or less for AC. DC -10% min., AC - 30% min. 110% 15% AC & DC Class "B" coil insulation system (130C per UL standard 1446) 2.3 Watts DC, 2.55 VA (60Hz) AC, approx. 5 minutes max. @ 40C Continuous SPDT, DPDT, 4PDT. 1 Amp Bifurcated Silver Gold plated. 3 AMP Silver Gold flashed 5 Amp, Silver Cadmium Oxide. 10 & 15 AMP, Silver Cadmium Oxide. 100 Milliohms Max.(3, 5, 10 & 15AMP) @ 6V, 1 AMP 50 Milliohms Max. ( 1 AMP) @ 6V, 0.1 AMP
IEC = INTERNATIONAL * ELECTROTECHNICAL COMMISSION
4PDT- Bifurcated 1Amp @ 120/240 VAC 30VDC. 1/16HP (2.8A FLA), 120VAC. Pilot duty - 5A make, 1/2A break, 1 A continuous, 120 VAC 4PDT- 3 Amps @ 120/240 VAC, 30VDC, 1/10HP 120/240VAC, C300 pilot duty. 4PDT- 5 Amps @ 120/240 VAC, 30VDC, 1/6 HP 120/240VAC, C300 pilot duty DPDT -10 Amps @ 120/240VAC, 30VDC.1/3 HP,120VAC. 1/2HP 240VAC. SPDT -15 Amps @ 120/240VAC, 30VDC.1/3 HP 120VAC, 1/2 HP 240VAC. 25mS Max. @ Nominal Voltage. 25 mS Max. @ Nominal Voltage. 1500 V rms 1000 V rms 1500 V rms 100 Megohms Min. @ 500 VDC. -40C to + 70C @ Rated Operation 10 to 55 Hz; 1mm ( Double Amplitude). Mechanical Durability, 1000 m/s2 (approx.100 G ). Malfunction Durability, 200 m/s2 (approx. 20 G ). 10,000,000 Operations (AC & DC). 200,000 Operations Min. (at rated Resistive load). Clear Polycarbonate Dust Cover, Molded. SPDT & DPDT 1.41 oz, (Approx. 40 g) , 4PDT 2.47 oz. (Approx. 70 g).
TIMING Operate Time: Release Time: DIELECTRIC STRENGTH Coil to Frame: Across Open Contacts: Contact to Frame: Insulation Resistance: TEMPERATURE Ambient Temperature: VIBRATION RESISTANCE Functional: , SHOCK RESISTANCE Mechanical Durability: Malfunction Durability: LIFE EXPECTANCY Mechanical (No Load): Electrical (rated Load): MISCELLANEOUS Enclosure: Weight:
NEW
EPOXY SEALED VERSIONS AVAILABLE. CONSULT FACTORY.
* RELEVANT IEC CONTACT UTILIZATION CATEGORIES
AC-1, AC-3, DC-1, AC-15
(SEE SECTION 11 FOR RELEVANT UTILIZATION CATEGORIES.)
WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
PAGE 8
CLASS
78
ICE CUBE STYLE SOLDER/PLUG-IN OR PC BOARD RELAY
OUTLINE DIMENSIONS Dimensions shown in INCHES and (MILLIMETERS) Optional FLANGED COVER available on special order as Non-Stock.
.138Typ. (.3.51) .020 Typ. (.51) 1 5 1.33 (33.8) 1.10 Max. (27.9) 1.72 Max. (43.7) 9 2 6
WIRING DIAGRAM FOR 4PDT RELAY
3 7 4 8 12
Observe polarity when L.E.D. Indicator is installed across coil. ( DC Styles Typ.) (-) 13 OR (+) 14
10 11
13
14
AC STYLES
DC STYLES
.079 (2.0) 1.40 Max. P.C. Style (35.56)
ALL INDICATOR LAMP STYLE RELAYS HAVE AN ADDITIONAL LAMP CIRCUIT INSTALLED ACROSS COIL. .020 (.51) .140 (3.56) .51 (12.95) .858 Max. (21.8)
P.C. STYLE Q.C. STYLE
.100 (2.54)
.51 (12.95)
.17 (4.32)
.17 (4.32)
.040 Max. (1.02)
.16 (4.06) .50 (12.7) .25 (6.35) .25 (6.35)
1.40 Max. (35.56) 1.65 Max. (41.91)
.250 max (6.35)
ALL 4 POLE RELAYS HAVE OPPOSITE POLARITY ARC BARRIERS AS A STANDARD FEATURE. ARC BARRIERS PROVIDE GREATER VOLTAGE PROTECTION BETWEEN ADJACENT POLES
ARC BARRIE R
.15 (3.81)
.05 dia. (1.27) 14 holes
P.C MOUNTING HOLE LAYOUT
( BOTTOM VIEW )
NEW! 1 AMP
4PDT
CONTACTS BIFURCATED 1 AMP W78ATCSX-2 W78ATCSX-3 W78ATCSX-5 W78ATCSX-6 W78ANTCSX-4 W78ANTCSX-5 W78ANTCSX-7 W78TCSX-1 W78TCSX-2 W78TCSX-3 W78TCSX-5 W78NTCSX-5 Coil measured @ 25C Nominal Nominal Nominal Power Resistance Input (Approx.) (Ohms) Voltage 12 VAC 24VAC 120 VAC 240 VAC 24 VAC 120VAC 240 VAC 6 VDC 12 VDC 24VDC 110 VDC 46 180 4430 15,700 180 4430 15,700 40 160 650 11,000 1.2VA 1.2VA 1.2VA 1.2VA 1.2VA 1.2VA 1.2VA 0.9W 0.9W 0.9W 1.1W
RELAYS
CROSS REFERENCE TO
POTTER & BRUMFIELD
IDEC
RY42S-U-AC12V RY42S-U-AC24V RY42S-U-AC110/120V RY42S-U-AC220/240V RY42S-UL-AC24V RY42S-UL-AC110/120V RY42S-UL-AC220/240V RY42S-U-DC6V RY42S-U-DC12V RY42S-U-DC24V RY42S-U-DC100/110V
OMRON
MY4Z-UA-AC12 MY4Z-UA-AC24 MY4Z-UA-AC120 MY4Z-UA-AC240 MY4ZN-UA-AC12 MY4ZN-UA-AC24 MY4ZN-UA-AC240 MY4Z-UA-DC6 MY4Z-UA-DC12 MY4Z-UA-DC24 MY4Z-UA-DC110 MY4ZN-UA-DC24
AC OPERATED COIL - SOLDER/PLUG-IN STYLE.
KHAU17A96-12 KHAU17A96-24 KHAU17A96-120 KHAU17A96-240
AC OPERATED COIL - SOLDER/PLUG-IN WITH INDICATOR LAMP.
KHAU17A96N-120
DC OPERATED COIL - SOLDER/PLUG-IN STYLE
KHAU17D96-6 KHAU17D96-12 KHAU17D96-24 KHAU17D96-110
DC OPERATED COIL - SOLDER/PLUG-IN WITH INDICATOR LAMP
24 VDC 0.9W KHAU17D96L-24 650 RY42S-UL-DC24V PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIUBUTION. SEE SECTION 10 FOR MATING SOCKETS
PAGE 9
WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
ICE CUBE STYLE SOLDER/PLUG-IN OR PC BOARD RELAY
CLASS
78
4PDT
CONTACTS
RELAYS - 3 AMP
CROSS REFERENCE TO
POTTER & BRUMFIELD
3 AMP
Coil measured @ 25C Nominal Nominal Nominal Power Resistance Input (Approx.) (Ohms) Voltage 12 VAC 24VAC 120 VAC 240 VAC 24 VAC 120VAC 240 VAC 6 VDC 12 VDC 24VDC 110 VDC 24 VDC 24 VAC 12 0 VAC 12 VDC 24 VDC 110 VDC 46 180 4430 15,700 180 4430 15,700 40 160 650 11,000 650 180 4430 160 650 11,000 1.2VA 1.2VA 1.2VA 1.2VA 1.2VA 1.2VA 1.2VA 0.9W 0.9W 0.9W 1.1W 0.9W 1.2VA 1.2VA 0.9W 0.9W 1.1W
IDEC
RY4S-U-AC12V RY4S-U-AC24V RY4S-U-AC110/120V RY4S-U-AC220/240V RY4S-UL-AC24V RY4S-UL-AC110/120V RY4S-UL-AC220/240V RY4S-U-DC6V RY4S-U-DC12V RY4S-U-DC24V RY4S-U-DC100/110V RY4S-UL-DC24V RY4V-U-AC24V RY4V-U-AC110/120V RY4V-U-DC12V RY4V-U-DC24V RY4V-U-DC100/110V
OMRON
MY4-UA-AC12 MY4-UA-AC24 MY4-UA-AC120 MY4-UA-AC240 MY4N-UA-AC12 MY4N-UA-AC24 MY4N-UA-AC240 MY4-UA-DC6 MY4-UA-DC12 MY4-UA-DC24 MY4-UA-DC110 MY4N-UA-DC24 MY4-02-UA-AC24 MY4-02-UA-AC120 MY4-02-UA-DC12 MY4-02-UA-DC24 MY4-02-UA-DC110
AC OPERATED COIL - SOLDER/PLUG-IN STYLE.
W78ACSX-2 W78ACSX-3 W78ACSX-5 W78ACSX-6 W78ANCSX-24 W78ANCSX-25 W78ANCSX-26 W78CSX-1 W78CSX-2 W78CSX-3 W78CSX-6 W78NCSX-23 W78APCX-3 W78APCX-5 W78PCX-2 W78PCX-3 W78PCX-6 KHAU17A91-12 KHAU17A91-24 KHAU17A91-120 KHAU17A91-240
AC OPERATED COIL - SOLDER/PLUG-IN WITH INDICATOR LAMP.
KHAU17A91N-120 KHAU17A91N-240 KHAU17D91-6 KHAU17D91-12 KHAU17D91-24 KHAU17D91-110 KHAU17D91N-24 KHAE17A11-24 KHAE17A11-120 KHAE17D11-12 KHAE17D11-24 KHAE17D11-110
DC OPERATED COIL - SOLDER/PLUG-IN STYLE
DC OPERATED COIL - SOLDER/PLUG-IN WITH INDICATOR LAMP AC OPERATED - PRINTED CIRCUIT STYLE DC OPERATED - PRINTED CIRCUIT STYLE
4PDT
CONTACTS
RELAYS - 5 AMP
CROSS REFERENCE TO
POTTER & BRUMFIELD
5 AMP
Coil measured @ 25C Nominal Nominal Nominal Power Resistance Input (Approx.) (Ohms) Voltage 12 VAC 24VAC 120 VAC 240 VAC 12 VDC 24VDC 46 180 4430 15,700 160 650 1.2VA 1.2VA 1.2VA 1.2VA 0.9W 0.9W
IDEC
RY4S-U-AC12V RY4S-U-AC24V RY4S-U-AC110/120V RY4S-U-AC220/240V RY4S-U-DC12V RY4S-U-DC24V
AC OPERATED COIL - SOLDER/PLUG-IN STYLE.
W78KACSX-15 W78KACSX-17 W78KACSX-18 W78KCSX-12 W78KCSX-13 KHAU17A21-12 KHAU17A21-24 KHAU17A21-120 KHAU17A21-240 KHAU17D21-12 KHAU17D21-24
DC OPERATED COIL - SOLDER/PLUG-IN STYLE
PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIUBUTION. SEE SECTION 10 FOR MATING SOCKETS
WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
PAGE 10
CLASS
78
ICE CUBE STYLE SOLDER/PLUG-IN OR PC BOARD RELAY
OUTLINE DIMENSIONS Dimensions shown in INCHES and (MILLIMETERS) DOUBLE POLE DOUBLE THROW 1 3 5
1.33 (33.8) 1.10 Max. (27.9) 1.72 Max. (43.7)
Optional FLANGED COVER available on special order as Non-Stock.
.138Typ. (.3.51)
2 4 6 8
.020 Typ. (.31)
Observe polarity when L.E.D. Indicator is installed across coil. ( DC Styles Typ.) (-) 7 OR (+) 8
7
AC STYLES
DC STYLES
.079 (2.0)
.080 Typ. (2.03) .040 (1.02) 1.375 Max. P.C. Style (34.92) .18 (4.57) .12 Dia. (3.04 ) Typ.
.187 Typ. (4.75)
ALL INDICATOR LAMP STYLE RELAYS HAVE AN ADDITIONAL LAMP CIRCUIT INSTALLED ACROSS COIL.
.858 Max. (21.8)
.560 (14.2) .39 (9.91) .16 (4.06) .18 (4.57) .52 (13.21) .28 (7.11)
Q.C. STYLE
1.375 Max. (34.92) .291 Max. (7.39)
P.C. STYLE
.13 (3.30)
0.10 dia.(2.54) 8 holes
P.C MOUNTING HOLE LAYOUT ( BOTTOM VIEW )
DPDT
DPDT, 10 AMP
STANDARD COVER
W78ARCSX-7 W78ARCSX-9 W78ARCSX-11 W78ARCSX-12 W78ARNCSX-6 W78ARNCSX-5 W78ARNCSX-7 W78RCSX-6 W78RCSX-7 W78RCSX-8 W78RCSX-9 W78RCSX-10 W78RNCSX-6 W78ARPCX-5 W78ARPCX-6 W78RPCX-1 W78RPCX-2 W78RPCX-3 78RCSX-1 78RCSX-2 78RCSX-3 78RCSX-4 78RCSX-5
RELAYS - 10 AMPS
CROSS REFERENCE TO*
POTTER & BRUMFIELD K10P11A15-6 K10P11A15-24 K10P11A15-120 K10P11A15-240
Coil measured @ 25C Nominal Nominal TOP FLANGE Input Resistance Nominal Power COVER (Approx.) Voltage (Ohms) 78ARCSX-1 78ARCSX-3 78ARCSX-5 78ARCSX-6 6 VAC 24VAC 120 VAC 240 VAC 24 VAC 120VAC 240 VAC 6 VDC 12 VDC 24VDC 48 VDC 110 VDC 24 VDC 120 VAC 240 VAC 6VDC 12 VDC 24 VDC 12.2 180 4430 15,700 180 4430 15,700 40 160 650 2,600 11,000 650 4430 15,700 40 160 650 1. VA 1.2VA 1.2VA 1.2VA 1.2VA 1.2VA 1.2VA 0.9W 0.9W 0.9W 0.9W 1.1W 0.9W 1.2VA 1.2VA 0.9W 0.9W 0.9W
IDEC
OMRON
AC OPERATED COIL - SOLDER/PLUG-IN STYLE.
RH2B-U-AC6V RH2B-U-AC24V RH2B-U-AC110/120V RH2B-U-AC220/240V LY2-UA-AC6 LY2-UA-AC24 LY2-UA-AC120 LY2-UA-AC240
AC OPERATED COIL - SOLDER/PLUG-IN WITH INDICATOR LAMP.
RH2B-UL-AC24V LY2N-UA-AC24 K10L11A15-120 RH2B-UL-AC110/120V LY2N-UA-AC120 RH2B-UL-AC220/240V LY2N-UA-AC240 K10P11D15-6 K10P11D15-12 K10P11D15-24 K10P11D15-48 K10P11D15-110 RH2B-U-DC6V RH2B-U-DC12V RH2B-U-DC24V RH2B-U-DC48V RH2B-UL-DC100/110V RH2B-UL-DC24V K10P11A55-120 RH2V2-U-AC110/120V K10P11A55-240 RH2V2-U-AC220/240V K10P11D55-6 K10P11D55-12 K10P11D55-24 RH2V2-U-DC6V RH2V2-U-DC12V RH2V2-U-DC24V LY2-UA-DC6 LY2-UA-DC12 LY2-UA-DC24 LY2-UA-DC48 LY2-UA-DC110 LY2N-UA-DC24 LY2-0-UA-AC120 LY2-0-UA-AC240 LY2-0-UA-DC6 LY2-0-UA-DC12 LY2-0-UA-DC24
DC OPERATED COIL - SOLDER/PLUG-IN STYLE
DC OPERATED COIL -SOLDER/PLUG-IN WITH INDICATOR LAMP AC OPERATED COIL -P.C. TERMINAL STYLE DC OPERATED COIL -P.C. TERMINAL STYLE
PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIUBUTION.
SEE SECTION 10 FOR MATING SOCKETS
* Applies to Standard Cover
PAGE 11
WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
ICE CUBE STYLE SOLDER/PLUG-IN OR PC BOARD RELAY
OUTLINE DIMENSIONS Dimensions shown in INCHES and (MILLIMETERS) Optional FLANGED COVER available on special order as Non-Stock.
.138Typ. (.3.51)
CLASS
78
Observe polarity when L.E.D. Indicator is installed across coil. (DC Styles Typ.)
SINGLE POLE DOUBLE THROW 1 3 2 4 6 8
.020 Typ. (.31) 1.33 (33.8) 1.10 Max. (27.9) 1.72 Max. (43.7)
5 7
(-) 7 OR
(+) 8
AC STYLES
DC STYLES
ALL INDICATOR LAMP STYLE RELAYS HAVE AN ADDITIONAL LAMP CIRCUIT INSTALLED ACROSS COIL.
.079 (2.0)
.080 Typ. (2.03) .040 (1.02) 1.375 Max. P.C. Style (34.92) .18 (4.57) .12 Dia. (3.04 ) Typ.
.187 Typ. (4.75)
.858 Max. (21.8)
.560 (14.2) .39 (9.91) .16 (4.06) .18 (4.57) .52 (13.21) .28 (7.11)
Q.C. STYLE
1.375 Max. (34.92) .291 Max. (7.39)
P.C. STYLE
.13 (3.30)
0.10 dia.(2.54) 8 holes
P.C MOUNTING HOLE LAYOUT ( BOTTOM VIEW )
SPDT RELAYS - 15 AMPS
SPDT, 15 AMP
STANDARD COVER TOP FLANGE COVER
78ARCSX-33 78ARCSX-34 78ARCSX-36 78ARCSX-37 Nominal Input Voltage 12 VAC 24VAC 120 VAC 240 VAC 24 VAC 120VAC 240 VAC 78RCSX-31 78RCSX-32 78RCSX-33 78RCSX-35 6 VDC 12 VDC 24VDC 110 VDC 24 VDC 12 VAC 24 VAC 120 VAC 12 VDC 24 VDC 110 VDC Coil measured @ 25C Nominal Resistance (Ohms) 46 180 4430 15,700 180 4430 15,700 40 160 650 11,000 650 46 180 4430 160 650 11,000 Nominal Power (Approx.) 1.2VA 1.2VA 1.2VA 1.2VA 1.2VA 1.2VA 1.2VA 0.9W 0.9W 0.9W 1.1W 0.9W 1.2VA 1.2VA 1.2VA 0.9W 0.9W 1.1W
CROSS REFERENCE TO *
OMRON
AC OPERATED COIL - SOLDER/PLUG-IN STYLE.
W78ARCSX-108 W78ARCSX-109 W78ARCSX-111 W78ARCSX-112 W78ARNCSX-8 W78ARNCSX-9 W78ARNCSX-10 W78RCSX-96 W78RCSX-97 W78RCSX-98 W78RCSX-100 W78RNCSX-10 W78ARPCX-81 W78ARPCX-82 W78ARPCX-84 W78RPCX-79 W78RPCX-83 W78RPCX-85 LY1-UA-AC12 LY1-UA-AC24 LY1-UA-AC120 LY1-UA-AC240 LY1N-UA-AC24 LY1N-UA-AC120 LY1N-UA-AC240 LY1-UA-DC6 LY1-UA-DC12 LY1-UA-DC24 LY1-UA-DC110 LY1N-UA-DC24 LY1-0-UA-AC12 LY1-0-UA-AC24 LY1-0-UA-AC120 LY1-0-UA-DC12 LY1-0-UA-DC24 LY1-0-UA-DC110
AC OPERATED COIL - SOLDER/PLUG-IN WITH INDICATOR LAMP
DC OPERATED COIL - SOLDER/PLUG-IN STYLE
DC OPERATED COIL - SOLDER/PLUG-IN WITH INDICATOR LAMP AC OPERATED COIL -P.C. TERMINAL STYLE
DC OPERATED COIL -P.C. TERMINAL STYLE
PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIUBUTION.
SEE SECTION 10 FOR MATING SOCKETS
* Applies to Standard Cover
WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
PAGE 12
CLASS
67
MINIATURE ENCLOSED INDUSTRIAL RELAY
CONTACT MATERIAL: SILVER GOLD OVERLAY RATED 3 or 5 AMPS @ 32VDC/120VAC WIRING DIAGRAM 8PDT
The Class 67 Relays have combination solder/plug-in terminals with a 3-48UNC stud or printed circuit terminals.
6PDT
UL RECOGNIZED FILE NO. E52197
4PDT
DPDT
Standard Class 67 miniature industrial relays are designed for applications requiringDPDT to 8PDT contacts where space and weight are of prime importance. Shatter resistant, see-thru plastic covers are utilized to protect against dust, tampering and electrical shock. The 67T models have Bifurcated Contacts and are designed for low level switching applications. SEE SECTION 10 FOR MATING SOCKETS.
4
1 2 3 Bottom View
TYPICAL CONTACT LIFE EXPECTANCY FOR SWITCHING RESISTIVE LOADS @ 25C Number of Operations Standard adjustment 5 X 104 5 X 104 1.5 X 106 1.2 X 107 5 X 107 5 X 107 5 X 107
CLASS 67 TYPICAL TIMING VALUES
Load Current 5.0A 5.0A 2.0A 1.0A 0.5A 0.1A 0.1A 50mA 30mA 1mA 10A
Load Voltage 28 VDC 120VAC 28VDC/120VAC 28VDC/120VAC 28VDC/120VAC 28VDC/120VAC 6 VDC 6 VDC 6 VDC 6 VDC 10mVDC
POLES OPERATE TIME
DPDT 012
4PDT
.014 .008
6PDT
.016 .008
8PDT
.018 .008
RELEASE TIME .008
Measured at Nominal Voltage @ 25C
SPECIFICATIONS CLASS 67
COIL Pickup voltage: Dropout voltage: Coil resistance: Maximum coil dissipation: Coil Temperature rise: Maximum coil temperature: 80% of nominal voltage or less. 10% of nominal or more. 10% measured @ 25C 2.2 watts 30C per watt 105C DIELECTRIC STRENGTH Contact to coil: Across open contacts: Coil to frame: Contacts to frame: Insulation resistance: 1500 V rms 500 V rms 1000 V rms 1500 V rms 1000 megohms @ 25C & 50% R.H.
CONTACTS Contact material: Contact resistance:
Silver, Gold overlay 50 milliohms max. initial
TEMPERATURE Operating: Storage:
-55C to + 70C -55C to +105C
CAPACITANCE Between contacts: Contact to coil: Coil to frame:
2 pf, typ. 2 pf, typ. 30 pf, typ.
MISCELLANEOUS Solder-bath temperature: +525F (260C) 10 seconds max. Enclosure Material: Polycarbonate see thru plastic cover. Operating Position: Any Weight: 0.77 to 1.4 oz. (22 to 40 grams) OPTIONS: Other options such as other coil voltages, sensitivities, contact arrangements and epoxy sealing are available on special order. Consult Factory for special requirements.
PAGE 13
WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
CLASS
MINIATURE ENCLOSED INDUSTRIAL RELAY
OUTLINE DIMENSIONS Dimensions shown in INCHES and (MILLIMETERS) DIMENSIONS
Tolerances .010 Inches
67
"A"
CONTACT CONFIGURATION
"A"
DIM. .978 (24.8) 1.156 (29.4) 1.374 (34.9) 1.592 (40.4))
1.20 Max. (30.3)
DPDT
4PDT
6PDT
.094 (2.3) .170 (4.3) .200 Max. (5.1) 3-48UNC-2A Thd.
8PDT
Elongated Hole .100 x .040 ( 2 x .1) All Contact Terminals are .010 Thick all coil terminals are .018 Thick.
P.C RELAY PIN LAYOUT
SUGGESTED PRINTED CIRCUIT BOARD LAYOUT FOR RELAYS WITH PRINTED CIRCUIT TERMINALS
"A"
.400 (10.2) .200 (5.1)
1.20 Max. (30.3)
.053 (1.35)
.630 .740 (18.8) .530 (16.0) (13. 4) .320 (8.1) .420 (10.6)
.135 (3.42)
COIL TERMINALS .032 (0.80) .735 Max. (18.7)
.210 (5.3) .110 (2.7)
.060 .002 Dia. (1.5) (.05)
.550 (13..97)
.098 (2.48) Typ.
.225 (5.7) .450 (11.43)
.165 (4.19) Typ.
.040 (1.0) Typ.
CONTACT TERMINALS
All Contact Terminals are .010 Thick. All Coil Terminals are .018 Thick.
WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
PAGE 14
CLASS
67
MINIATURE ENCLOSED INDUSTRIAL RELAY
DC OPERATED - SOLDER TERMINAL or PLUG-IN STYLE STANDARD CONTACTS PART NUMBERS W67RCSX-1 W67RCSX-2 W67RCSX-3 W67RCSX-4 W67RCSX-5 W67RCSX-6 W67RCSX-7 W67RCSX-8 W67RCSX-9 W67RCSX-10 W67RCSX-12 W67RCSX-13 W67RCSX-17 W67RCSX-18 CONTACT RATING 5 AMPS 5 AMPS 5 AMPS 5 AMPS 5 AMPS 5 AMPS 5 AMPS 5 AMPS 5 AMPS 5 AMPS 5 AMPS 5 AMPS 5 AMPS 5 AMPS
COIL
NOMINAL INPUT VOLTAGE 5 12 24 48 115 5 12 24 48 115 12 24 12 24
Measured @ 25C NOMINAL POWER (WATTS) 1/2W 3/4W 1W 1W 1W 1/2W 3/4W 1W 1W 1W 1.5W 1.5W 2W 2W CONTACT CONFIGURATION DPDT DPDT DPDT DPDT DPDT 4PDT 4PDT 4PDT 4PDT 4PDT 6PDT 6PDT 8PDT 8PDT CROSS REFERENCE TO POTTER & BRUMFIELD R10E1(X or Y)2-V28 R10E1(X or Y)2-V185 R10E1(X or Y)2-V700 R10E1(X or Y)2-V2.5K R10E1(X or Y2-V15.0K R10E1(X or Y)4-V28 R10E1(X or Y)4-V185 R10E1(X or Y)4-V700 R10E1(X or Y)4-V2.5K R10E1(X or Y)4-V15.0K R10E1(X or Y)6-V185 R10E1(X or Y)6-V700 R10E1(X or Y)8-V185 R10E1(X or Y)8-V700
NOMINAL RESISTANCE (OHMS) 52 185 700 2500 15,000 52 185 700 2500 15,000 90 430 72 350
DC OPERATED - BIFURCATED CONTACTS - FOR LOW LEVEL SWITCHING APPLICATIONS W67TRCSX-2 W67TRCSX-3 W67TRCSX-7 W67TRCSX-8 W67TRCSX-12 W67TRCSX-13 W67TRCSX-17 W67TRCSX-18 3 AMPS 3 AMPS 3 AMPS 3 AMPS 3 AMPS 3 AMPS 3 AMPS 3 AMPS 12 24 12 24 12 24 12 24 185 700 185 700 90 430 72 350 3/4W 1W 3/4W 1W 1.5W 1.5W 2W 2W DPDT DPDT 4PDT 4PDT 6PDT 6PDT 8PDT 8PDT R10E1(P or Z)2-V185 R10E1(P or Z)2-V700 R10E1(P or Z)4-V185 R10E1(P or Z)4-V700 R10E1(P or Z)6V185 R10E1(P or Z)6-V700 R10E1(P or Z)8-V185 R10E1(P or Z)8-V700
DC OPERATED - PRINTED CIRCUIT STYLE STANDARD CONTACTS PART NUMBERS W67RPCX-2 W67RPCX-3 W67RPCX-7 W67RPCX-8 W67RPCX-12 W67RPCX-13 CONTACT RATING 5 AMPS 5 AMPS 5 AMPS 5 AMPS 5 AMPS 5 AMPS
COIL
NOMINAL INPUT VOLTAGE 12 VDC 24 VDC 12 VDC 24 VDC 12 VDC 24 VDC
Measured @ 25C NOMINAL NOMINAL POWER RESISTANCE (WATTS) (OHMS) 185 1W 700 1W 185 1W 700 1W 90 1.5W 430 1.5W
CONTACT CONFIGURATION DPDT DPDT 4PDT 4PDT 6PDT 6PDT
CROSS REFERENCE TO POTTER & BRUMFIELD R10E2(X or Y)2-V185 R10E2(X or Y)2-V700 R10E2(X or Y)4-V185 R10E2(X or Y)4-V700 R10E2(X or Y)6-V185 R10E2(X or Y)6-V700
CLASS 67 - AC OPERATED RELAYS - SOLDER TERMINAL or PLUG-IN STYLE 50/60 Hz STANDARD CONTACTS COIL Measured @ 25C CONTACT NOMINAL NOMINAL NOMINAL CONFIGUCONTACT PART NUMBERS POWER INPUT RESISTANCE RATION RATING (WATTS) VOLTAGE (OHMS) W67ARCSX-5 120 VAC 1.5VA 5 AMPS DPDT W67ARCSX-10 120 VAC 5 AMPS 2.5VA 4PDT W67ARCSX-15 120 VAC 2.5VA 5 AMPS 6PDT
CROSS REFERENCE TO POTTER & BRUMFIELD R10E1(X or Y)2-120V R10E1(X or Y)4-120V R10E1(X or Y)6-120V
Part numbers shown also available thru Stocking Distribution. STANDARD CONTACTS
(5 AMP CROSS BAR)
BIFURCATED CONTACTS
( LOW LEVEL APPLICATIONS)
SEE SECTION 10 FOR MATING SOCKETS PAGE 15 WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
OCTAL STYLE 10 AMP GENERAL PURPOSE RELAY
FEATURES Plug-in, 8 or 11 pin "Octal Style Base" with see thru plastic dust cover. Standard SPDT, DPDT or 3PDT contact arrangements. Other contact arrangements available on special order. Dielectric Strength to 1500 Vrms. 8 or 11 pin octal style plug-in are standard and Interchangeable with other general purpose relays of this type. Available with combinations of Indicator lamps, push to test button and Blow-out Magnets for DC switching applications. MANUFACTURED UNDER QUALITY SYSTEM
CLASS
A314 & 250
ISO 9002 & QS 9000
Recognized Component mark for Canada and the United States.
C
US
UL Recognized File No. E43641
WIRING DIAGRAM
VIEWED FROM PIN END
(-)
3PDT
(+)
(-)
DPDT
(+)
SPDT
ALL INDICATOR LAMP STYLE RELAY HAVE AN ADDITIONAL LAMP CIRCUIT INSTALLED ACROSS COIL. OBSERVE COIL POLARITY WHEN L.E.D. INDICATOR IS INSTALLED ACROSS COIL (DC STYLES TYP.).
OUTLINE DIMENSIONS
Dimensions are shown in Inch and (Millimeter).
Artwork marking side
2.81 max. (71.4) 2.25 max. (57.2) 4 3 1.37 (34.79)
5
6
1.37 (34.79)
2 1 8
7
CONTACT RATINGS TABLE
POLES SPDT DPDT 120 VAC 12 AMP 1/3 HP 12 AMP 1/3 HP 10 AMP 1/3 HP 240 VAC 12 AMP 1/2 HP 10 AMP 1/2 HP 10 AMP 1/2 HP 28 VDC 10 AMP
10 AMP
3PDT
10 AMP
SEE SECTION 10 FOR MATING SOCKETS WEBSITE: www.magnecraft.com - EMAIL:info@magnecraft.com - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100 PAGE 16
CLASS
A314 & 250
CLASS A314 & 250
OCTAL STYLE 10 AMP GENERAL PURPOSE RELAY
Recognized Component mark for Canada and the United States.
8 OR 11 PIN OCTAL PLUG-IN WITH SEE THRU DUST COVER. Enclosure is a clear high impact plastic (polycarbonate) dust cover that is screwed to the base to protect against dust, damage and tampering.
UL Recognized File No. E43641
C
US
SPECIFICATIONS SERIES A314 & 250 RELAYS
COIL Pull-in voltage: Drop-out: Coil resistance: Minimum sensitivity: Nominal power: Maximum coil dissipation: Duty: CONTACTS Contact material: Contact resistance: Minimum Load: TIMING Operate time: Release time: DIELECTRIC STRENGTH Contacts to coil: Across open contacts: Pole to pole: Contacts to frame: Insulation resistance: TEMPERATURE Ambient Temperature (Operating): Non operating storage: SHOCK RESISTANCE Operating: Non operating: VIBRATION RESISTANCE Operating: MISCELLANEOUS Enclosure: Insulation material: Operating Position: Terminals: Weight:
80% of nominal voltage or less. for DC coils 85% of nominal voltage or less for AC coils. 10% of nominal voltage or more. 10 % measured @ 25 C 125 milliwatts per pole 1.2 Watts for DC coils, 2 VA-2.75VA for AC coils Capability of DC coils 3.0 Watts max. Continuous
3/16" silver cadmium oxide, gold flashed Std. Gold Diffused also available. 50 milliohms maximum initial resistance at rated current 12 V @ 100 Milliamps
15 mS or less at nominal voltage. 10 mS or less at nominal Voltage.
1500 V rms 500 V rms 1500 V rms 1500 V rms 1,000 Megohms min. @ 500 VDC
-45C to +55C (AC), -45C to +70C (DC) -45C to +105C
5 G's, 20 G's
5 G's, 10 Hz to 55 Hz
Plastic dust cover with octal plug. Molded plastic Any 8 or 11 pin octal plug-in 3 1/2 ozs. 99.2 g approx.
SEE SECTION 10 FOR MATING SOCKETS PAGE 17 WEBSITE: www.magnecraft.com - EMAIL:info@magnecraft.com - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
OCTAL STYLE 10 AMP GENERAL PURPOSE RELAY
Struthers-Dunn
CLASS
A314 & 250
RELAYS CAN BE ORDERED EITHER BY MAGNECRAFT OR STRUTHERS-DUNN PART NUMBERS LISTED BELOW DUAL MARKED PART NUMBERS
Struthers-Dunn
SERIES A314 AC OPERATED A314XAX48P-24A A314XAX48P-120A A314XBX48P-24A A314XBX48P-120A A314XBX48P-240A A314XCX48P-24A A314XCX48P-120A A314XCX48P-240A CLASS 250CP W250ACPX-3 W250ACPX-4 W250ACPX-8 W250ACPX-9 W250ACPX-10 W250ACPX-13 W250ACPX-14 W250ACPX-15
CONTACT CONFIGURATION SPDT SPDT DPDT DPDT DPDT 3PDT 3PDT 3PDT
COIL Measured @ 25C NOMINAL NOMINAL NOMINAL RESISINPUT POWER TANCE VOLTAGE 24 VAC 120VAC 24 VAC 120VAC 240 VAC, 60 Hz 220 VAC, 50 Hz 24 VAC 120 VAC 240 VAC. 60 Hz 220 VAC, 50 Hz 2.0VA 2.0VA 2.75VA 2.75VA 2.75VA 2.75VA 2.75VA 2.75VA
CROSS REFERENCE TO POTTER & IDEC BRUMFIELD
*
KRPA5AG (or GF) -24 KRPA5AG (or GF) -120 KRPA11AG (or GF) -24 RR2P-U-AC24V KRPA11AG (or GF) -120 RR2P-U-AC120V KRPA11AG (or GF) -240 RR2P-U-AC240V KRPA14AG (or GF) -24 RR3PA-U-AC24V KRPA14AG (or GF) -120 RR3PA-U-AC120V KRPA14AG (or GF) -240 RR3PA-U-AC240V
AC OPERATED WITH INDICATOR LAMP A314XBX48PL-24A W250ANCPX-26 A314XBX48PL-120A W250ANCPX-27 A314XBX48PL-240A W250ANCPX-28 A314XCX48PL-24A W250ANCPX-29 A314XCX48PL-120A W250ANCPX-30 A314XCX48PL-24OA W250ANCPX-31 DC OPERATED A314XAX48P-12D A314XAX48P-24D A314XBX48P-12D A314XBX48P-24D A314XCX48P-12D A314XCX48P-24D W250CPX-2 W250CPX-3 W250CPX-6 W250CPX-7 W250CPX-10 W250CPX-11 SPDT SPDT DPDT DPDT 3PDT 3PDT 12 VDC 24 VDC 12VDC 24 VDC 12 VDC 24 VDC 120 472 120 472 120 472 472 472 1.2W 1.2W 1.2W 1.2W 1.2W 1.2W KRPA5DG (or GF) -12 KRPA5DG (or GF) -24 KRPA11DG (or GF) -12 KRPA11DG (or GF) -24 KRPA14DG (or GF) -12 KRPA14DG (or GF) -24 RR2P-U-DC12V RR2P-U-DC24V RR3PA-U-DC12V RR3PA-U-DC24V DPDT DPDT DPDT 3PDT 3PDT 3PDT 24 VAC 120 VAC 240 VAC. 60 Hz 220 VAC, 50 Hz 24 VAC 120 VAC 240 VAC. 60 Hz 220 VAC, 50 Hz 2.0VA 2.0VA 2.75VA 2.0VA 2.0VA 2.75VA KRPA11AN (or NF) -24 RR2P-UL-AC24V KRPA11AN (or NF) -120 RR2P-UL-AC120V KRPA11AN (or NF) -240 RR2P-UL-AC240V KRPA14AN (or NF) -24 RR3PA-UL-AC24V KRPA14AN (or NF) -120 RR3PA-UL-AC120V KRPA14AN (or NF) -240 RR3PA-UL-AC240V
DC OPERATED WITH INDICATOR LAMP A314XBX48PL-24D A314XCX48PL-24D W250NCPX-20 W250NCPX-21 DPDT 3PDT 24 VDC 24 VDC 1.2 W 1.2 W KRPA11DN (or NF) -24 KRPA14DN (or NF) -24 RR2P-UL-DC24V RR3PA-UL-DC24V
PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION
*F = GOLD FLASHED
CONTACT RATINGS WITH BLOW-OUT MAGNET POLES DPDT 120 VAC 12 AMP 1/3 HP 240 VAC 10 AMP 1/2 HP 30 VDC 10 AMP 150 VDC 3 AMP
RELAYS FOR DC SWITCHING
PART NUMBERS CONTACT NO. OF PINS CONFIGUOCTAL RATION STYLE
-
COIL Measured @ 25C NOMINAL NOMINAL NOMINAL INPUT RESISTANCE POWER VOLTAGE (OHMS)
AC OPERATED WITH BLOW-OUT MAGNET A314XBX48P69-24A A314XBX48P69-120A DPDT DPDT 8 PIN 8 PIN 24 VAC 120VAC 120 472 10,000 2.0 VA 2.0 VA
DC OPERATED WITH BLOW-OUT MAGNET A314XBX48P69-12D A314XBX48P69-24D A314XBX48P69-110D DPDT DPDT DPDT 8 PIN 8 PIN 8 PIN 12 VDC 24 VDC 110 VDC 1.2 W 1.2 W 1.2 W
RELAYS USING MAGNETIC BLOW-OUT MAGNETS ARE NOT AGENCY APPROVED.
WEBSITE: www.magnecraft.com - EMAIL:info@magnecraft.com - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
PAGE 18
SERIES
284
GENERAL PURPOSE 4 POLE 10 AMP PLUG-IN RELAY
The series 284 relay is a extension of the Class 388/283 style relay except it provides for 4PDT contacts, any one set of contacts capable of switching 10 Amps (total load of 30 Amps at 120 VAC and 20 Amps at 240 VAC). This relay has the 3 way terminal design for greater flexibility in making connections. The 0.187 Spade terminals can be soldered, plugged into sockets or connected using 3/16" Q.C. Female connectors. UL Recognized File No. E13224
OUTLINE DIMENSIONS
Dimensions shown are in INCHES and (millimeters)
1.50 (38.1) 1.31 (33.3)
0.218 (5.53)
1.93 (49.0)
MANUAL PUSH BUTTON ACTUATOR (OPTIONAL)
1.87 (47.4)
0.020 Typ. (.508)
0.28 (7.11)
0.187 Typ. (4.74)
Struthers-Dunn
ORDERING CODE Typical Type No.
WIRING DIAGRAM
(VIEWED FROM TERMINAL END)
284 XDX C GLM -240A
1 5 9 13 2 6 10 3 7 11 4 8 12 14
Series 284 3 way terminals 10 Amp, 4 pole Contact Arrangements XDX (4PDT) Construction Style Open, with tapped 6-32 hole - NO CODE Open, with 6-32 Stud - CODE S Enclosed, 3 way terminals - CODE C Options 10 Amp contacts Standard - NO CODE Gold diffused contacts - CODE G Indicator Lamp - CODE L Manual Actuator - CODE M Printed Circuit Terminals - CODE T 5 Amp contacts (Silver) - CODE Y Coil Voltage AC: 6, 12, 24, 48, 120, 240 (Add "A") DC: 6, 12, 24, 48, 115, 125 (Add "D") SEE NEXT PAGE FOR RATINGS & SPECIFICATIONS
PAGE 19
WEBSITE: www.magnecraft.com - EMAIL:info@magnecraft.com - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
GENERAL PURPOSE 4 POLE 10 AMP PLUG-IN RELAY
SERIES
284
UL Recognized File No. E13224 LOAD CONTACT RATINGS 120VAC 30VDC 10A 10A 1/3Hp 240VAC 10A 1/2Hp
Resistive Motor Load 80% pF.
Maximum total load for 4 pole relay is 30 Amps @ 120VAC, 20Amps @ 240VAC GENERAL SPECIFICATIONS COIL Pull-in Voltage: Dropout Voltage: Max. allowed voltage: Coil Resistance: CONTACTS Contact Material: TIMING Operate Time: Release Time: DIELECTRIC STRENGTH All Mutually Insulated Points: AC: 85%, DC: 75% of nominal voltage measured at 25C 10% of nominal voltage or more @ 25C 110% of nominal voltage 10% Measured @ 25C
Silver Cadmium Oxide.
15 mS Max. @ Nominal Voltage. 10 mS Max. @ Nominal Voltage.
Insulation Resistance: TEMPERATURE Temperature Rating:
500 V rms across open contacts 1500 V rms between current carrying parts 1000 Megohms.min. @ 500 VDC
AC: -45C to +50C @ Rated Operation. (+65C for open style) DC: -45C to +70 C +85C for open style) 10 Million Operations no load 100,000 Operations @ Rated Load.
LIFE EXPECTANCY Mechanical: Electrical: MISCELLANEOUS Enclosure: Weight:
Clear polycarbonate 5.0 oz. approx..
COIL SPECIFICATIONS @ 25C Nominal Voltage 6 12 24 48 120AC or 115-125DC 240AC* Current (MA) Resistance Resistance Ohms 10% Ohms 10% AC AC DC DC 3 30 200 560 120 12 100 230 48 480 50 115 1920 25 870 8200 13-15 31 4700 -* 12 -* Power Consumption AC DC 3.4VA 1.2W 3.4VA 1.2W 3.4VA 1.2W 3.4VA 1.2W 3.4VA 1.2W 3.4VA 1.2W
NOTE: * For 220-250VDC coils use a 8,200 , 5 Watt resistor in series with 110-125 VDC relays
WEBSITE: www.magnecraft.com - EMAIL:info@magnecraft.com - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
PAGE 20
CLASS
388 & A283
GENERAL SPECIFICATIONS
MANUFACTURED UNDER The Class 388 & 283 general purpose relays are available in a wide choice of AC or DC voltages with Indicator Lamp, Push to test QUALITY SYSTEM button and other options. Plug-in style relays have 3-way pierced ISO 9002 & QS 9000 terminals. While spaced for standard plug-in Socket mounting. The flat terminals (0.187 x 0.020) also accept quick connect receptacles or direct soldering.
Recognized Component mark for Canada and the United States.
*
COMPLIES WITH REQUIREMENTS OF IEC STANDARDS 947-4-1 AND 947-5-1 LOW VOLTAGE DIRECTIVE
UL Recognized File No. E43641
C
US
IEC = INTERNATIONAL * ELECTROTECHNICAL COMMISSION
NEW!
PLUG-IN
FLANGE MOUNT
P.C. MOUNT
TOP FLANGE MOUNT
CONTACT RATINGS TABLE POLES 1 POLE 2 POLE 120 VAC 13 AMP 1/3 HP 13 AMP 1/3 HP 13 AMP 1/3 HP 240 VAC 13 AMP 1/2 HP 12 AMP 1/2 HP 11 AMP 1/2 HP 28 VDC 13 AMP
TYPICAL OPERATING CHARACTERISTICS
(For DC Voltage types only).
POLES MIN. OPERATE mW (SENSITIVITY) OPERATE TIME (Milliseconds maximum.) RELEASE TIME (Milliseconds Maximum.)
SPDT 125
DPDT 250
3PDT 375
12 AMP
18.0
20.0
24.0
3 POLE
11 AMP
30.0
28.0
26.0
WIRING DIAGRAMS
Viewed from terminal end 1 4 7 A 2 5 8 3 6 9 B 1 4 7 A 2 5 8 3 6 9 B 1 4 7 A 2 5 8 3 6 9 B
SPDT
DPDT
3PDT
* RELEVANT IEC CONTACT UTILIZATION CATEGORIES
AC-1, AC-3, DC-1, AC-15
(SEE SECTION 11 FOR RELEVANT UTILIZATION CATEGORIES.)
SEE SECTION 10 FOR MATING SOCKETS PAGE 21 WEBSITE: www.magnecraft.com - EMAIL:info@magnecraft.com - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
GENERAL SPECIFICATIONS
CLASS
388 & A283
SPECIFICATIONS CLASS 388 & 283 RELAYS
COIL Pull-in voltage: Dropout voltage: Resistance: Coil power Insulation System: Maximum coil dissipation: Duty: CONTACTS Contact material: Contact resistance:
80% of nominal voltage or less. for DC coils. 85% of nominal voltage or less for AC coils. 10% of nominal voltage or more. 10 % Measured at 25C 1.2 Watts for DC coils, 2 VA to 2.75 VA for AC coils Class "B" (130C per UL std. 1446) Capability of DC coils 3.0 Watts max. Continuous
3/16" silver cadmium oxide, gold flashed. 50 Milliohms maximum initial resistance at rated current
DIELECTRIC STRENGTH Contacts to coil: Across open contacts: Pole to pole Contacts to frame: Insulation resistance: TEMPERATURE Operating: Storage LIFE EXPECTANCY Electrical: Mechanical: MISCELLANEOUS Operating Position: Insulation material: Enclosure: Terminals:
2000 V rms 500 V rms 2000 V rms 2000 V rms 1000 Megohms @ 500 VDC
-30C to +50C (AC), -30C to +65C (DC) -30C to 100C
100,000 Operations @ rated AC load 5,000,000 Operations @ No load
Weight:
Any Molded plastic Clear Polycarbonate dust cover 3/16" solder/plug-in, Printed Circuit terminals other terminals available: .205 x .032, .250 x .032 on special order. Consult Factory. 3.1 oz.. (88 g approx. with cover).
OPTIONAL
TOP FLANGE COVER IS AVAILABLE ON SPECIAL ORDER. CONSULT FACTORY.
1.41 (35.8)
2.53 (64.29)
1.90Max. (48.4)
1.40Max. (35.5)
.500 (12.7)
SEE SECTION 10 FOR MATING SOCKETS WEBSITE: www.magnecraft.com - EMAIL:info@magnecraft.com - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100 PAGE 22
CLASS
388 & A283
SQUARE BASE RELAY, SOLDER/PLUG-IN
Recognized Component mark for Canada and the United States.
CLASS 388 & 283 RELAY
13 AMP CONTACT RATING
OPTIONAL INDICATOR LAMP AND PUSH TO TEST BUTTON AVAILABLE ON SPECIAL ORDER. MANUFACTURED UNDER QUALITY SYSTEM
UL Recognized File No. E43641
C
US
*
COMPLIES WITH REQUIREMENTS OF IEC STANDARDS 947-4-1 AND 947-5-1 LOW VOLTAGE DIRECTIVE
ISO 9002 & QS 9000
IEC = INTERNATIONAL * ELECTROTECHNICAL COMMISSION
OUTLINE DIMENSIONS Dimensions shown are in "INCH" and (Millimeter)
1.53 Max. (38.8)
1.90Max. (48.4)
.187 x .020 (4.76 x 0.51) QC Terminals Typical 1 4 2 5 8 3 6 9
1.40Max. (35.5)
7
A .28 Typ. (7.1)
B
* RELEVANT IEC CONTACT UTILIZATION CATEGORIES
Struthers-Dunn
DUAL MARKED PART NUMBERS CONTACT CONFIGURATION
AC-1, AC-3, DC-1, AC-15
(SEE SECTION 11 FOR RELEVANT UTILIZATION CATEGORIES.)
RELAYS CAN BE ORDERED EITHER BY MAGNECRAFT OR STRUTHERS-DUNN PART NUMBERS LISTED BELOW
Struthers-Dunn
CLASS 388CP AC OPERATED W388ACPX-3 W388ACPX-4 W388ACPX-5 W388ACPX-8 W388ACPX-9 W388ACPX-10 W388ACPX-13 W388ACPX-14 W388ACPX-15 DC OPERATED W388CPX-2 W388CPX-3 W388CPX-6 W388CPX-7 W388CPX-8 W388CPX-10 W388CPX-11 A283XAXC-24A A283XAXC-120A A283XAXC-240A A283XBXC-24A A283XBXC-120A A283XBXC-240A A283XCXC-24A A283XCXC-120A A283XCXC-240A CLASS A283
NOMINAL INPUT VOLTAGE
COIL Measured @ 25C NOMINAL NOMINAL RESISTANCE POWER 2.0VA 2.0VA 2.0VA 2.0VA 2.0VA 2.0VA 2.75VA 2.75VA 2.75VA 2.75VA 1.2W 1.2W 1.2W 1.2W 1.2W 1.2W 1.2W
CROSS REFERENCE TO POTTER & BRUMFIELD IDEC
SPDT SPDT SPDT DPDT DPDT DPDT 3PDT 3PDT 3PDT
24 VAC 120VAC 240 VAC, 60 Hz 220 VAC, 50 Hz 24 VAC 120 VAC 240 VAC. 60 Hz 220 VAC, 50 Hz 24 VAC 120 VAC 240VAC, 60Hz 220 VAC, 50Hz
-
KUP5A15 (or F) - 24 KUP5A15 (or F) - 120 KUP5A15 (or F) - 240 KUP11A15 (or F) - 24 KUP11A15 (or F) - 120 KUP11A15 (or F) - 240 KUP14A15 (or F) - 24 KUP14A15 (or F) - 120 KUP14A15 (or F) - 240
RR1BA-U-AC24V RR1BA-U-AC120V RR1BA-U-AC240V RR2BA-U-AC24V RR2BA-U-AC120V RR2BA-U-AC240V RR3B-U-AC24V RR3B-U-AC120V RR3B-U-AC240V
A283XAXC-12D A283XAXC-24D A283XBXC-12D A283XBXC-24D A283XBXC-110D A283XCXC-12D A283XCXC-24D
SPDT SPDT DPDT DPDT DPDT 3PDT 3PDT
12 VDC 120 24 VDC 472 12 VDC 120 24 VDC 472 110VDC 10,000 12 VDC 120 24 VDC 472
KUP5D15 (or F) - 12 KUP5D15 (or F) - 24 KUP11D15 (or F) - 12 KUP11D15 (or F) - 24 KUP11D15 (or F) - 110 KUP14D15 (or F) - 12 KUP14D15 (or F) - 24
F = GOLD FLASHED
RR1BA-U-DC12V RR1BA-U-DC24V RR2BA-U-DC12V RR2BA-U-DC24V RR2B-U-DC110V RR3B-U-DC12V RR3B-U-DC24V
PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION. SEE GENERAL SPECIFICATIONS & WIRING DIAGRAMS FOR CLASS 388 & A283 RELAYS.
SEE SECTION 10 FOR MATING SOCKETS PAGE 23 WEBSITE: www.magnecraft.com - EMAIL:info@magnecraft.com - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
CLASS
SQUARE BASE FLANGE MOUNT RELAYS
Recognized Component mark for Canada and the United States. COMPLIES WITH REQUIREMENTS OF IEC STANDARDS 947-4-1 AND 947-5-1 LOW VOLTAGE DIRECTIVE
388 & A283
FLANGE MOUNT RELAY
13 AMP CONTACT RATING .187 Q.C. /SOLDER TERMINALS
TOP FLANGE COVER AVAILABLE ON SPECIAL ORDER. CONSULT FACTORY OPTIONAL INDICATOR LAMP AND PUSH TO TEST BUTTON AVAILABLE ON SPECIAL ORDER. MANUFACTURED UNDER QUALITY SYSTEM
UL Recognized File No. E43641
C
US
*
IEC = INTERNATIONAL * ELECTROTECHNICAL COMMISSION
ISO 9002 & QS 9000
2.90Max. (73.8) 2.50 (63.5) .187 x .020 (4.76 x 0.51) QC Terminals Typical
1.53 Max. .625 Typ. (38.8) (15.8) .156 (3.9) .187 (4.76) 1.90Max. (48.4)
1 4 2 5 8 3 6 9 B
1.40Max. (35.5)
7 A
.28 Typ. (7.1)
* RELEVANT IEC CONTACT UTILIZATION CATEGORIES
Struthers-Dunn
AC-1, AC-3, DC-1, AC-15
(SEE SECTION 11 FOR RELEVANT UTILIZATION CATEGORIES.)
RELAYS CAN BE ORDERED EITHER BY MAGNECRAFT OR STRUTHERS-DUNN PART NUMBERS LISTED BELOW CROSS REFERENCE TO COIL Measured @ 25C DUAL MARKED PART NUMBERS NOMINAL NOMINAL CONTACT POTTER & Struthers-Dunn RESIS- NOMINAL IDEC INPUT CONFIGURATION BRUMFIELD TANCE POWER W388CQ A283 VOLTAGE (OHMS) AC OPERATED RR1BA-US-AC120V KUP5A55 (or F) - 120 W388ACQX-4 A283XAXC1-120A SPDT 2.0VA 120 VAC RR1BA-US-AC240V KUP5A55 (or F) - 240 W388ACQX-5 A283XAXC1-240A SPDT 240 VAC, 60Hz 2.0VA 220 VAC, 50 Hz KUP11A55 (or F) - 120 RR2BA-US-AC120V W388ACQX-9 A283XBXC1-120A DPDT 2.0VA 120 VAC KUP11A55 (or F) - 240 RR2BA-US-AC240V W388ACQX-10 A283XBXC1-240A DPDT 240 VAC. 60 Hz 2.0VA 220 VAC, 50 Hz KUP14A55 (or F) - 120 RR3B-US-AC120V W388ACQX-14 A283XCXC1-120A 3PDT 2.75VA 120 VAC KUP14A55 (or F) - 240 RR3B-US-AC240V W388ACQX-15 A283XCXC1-240A 3PDT 240VAC, 60Hz 2.75VA 220 VAC, 50Hz DC OPERATED RR1BA-US-DC12V KUP5D55 (or F) - 12 A283XAXC1-12D W388CQX-2 SPDT 1.2W 12 VDC 120 RR1BA-US-DC24V KUP5D55 (or F) - 24 A283XAXC1-24D W388CQX-3 SPDT 1.2W 24 VDC 472 RR2BA-US-DC12V KUP11D55 (or F) - 12 A283XBXC1-12D W388CQX-6 DPDT 1.2W 12 VDC 120 RR2BA-US-DC24V KUP11D55 (or F) - 24 A283XBXC1-24D W388CQX-7 DPDT 1.2W 24 VDC 472 RR3B-US-DC24V KUP14D55 (or F) - 24 W388CQX-11 A283XCXC1-24D 3PDT 1.2W 24 VDC 472
F = GOLD FLASHED PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION. SEE GENERAL SPECIFICATIONS & WIRING DIAGRAMS FOR CLASS 388 & A283 RELAYS.
WEBSITE: www.magnecraft.com - EMAIL:info@magnecraft.com - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
PAGE 24
CLASS
388B & A283 SQUARE BASE RELAYS WITH MAGNETIC BLOWOUT
CLASS 388B & 388DB
SQUARE BASE PLUG-IN STYLE WITH MAGNETIC BLOWOUT FOR DC SWITCHING. RATED 3 & 10 AMPS AT 150 VDC
TOP FLANGE COVER AVAILABLE ON SPECIAL ORDER. CONSULT FACTORY MANUFACTURED UNDER QUALITY SYSTEM
Recognized Component mark for Canada and the United States.
UL Recognized File No. E43641 & E13224
C
US
*
COMPLIES WITH REQUIREMENTS OF IEC STANDARDS 947-4-1 AND 947-5-1 LOW VOLTAGE DIRECTIVE
IEC = INTERNATIONAL * ELECTROTECHNICAL COMMISSION
OUTLINE DIMENSIONS Dimensions shown are in "INCHES" and (Millimeters)
ISO 9002 & QS 9000
1.53 Max. (38.8)
1.90Max. (48.4)
.187 x .020 (4.76 x 0.51) QC Terminals Typical 1 4 2 5 8 3 6 9
1.40Max. (35.5)
7
A .28 Typ. (7.1)
B
The Class 388B/388DB style relays have the same load specifications as the 388/283 enclosed plug-in style relays plus the additional load ratings charted on this page. See 388& A283 General specifications.
WIRING DIAGRAM
Viewed from terminal end 1 4 7 A 3 6 9 B A B
DC LOAD RATINGS
DPDT FIG. "A" RESISTIVE 3 AMPS 150VDC SPDT-N.O. -DM FIG. "B" 10 AMPS 150VDC ALSO AVAILABLE RESISTIVE DPST-NO & DPST-NC CONTACT VERSIONS WITH BLOWOUT MAGNETS NOW UL APPROVED @ 5 AMPS, 150 VDC.
4
6
DPDT FIG. "A"
SPST-NO-DM FIG. "B"
* RELEVANT IEC CONTACT UTILIZATION CATEGORIES
Struthers-Dunn
AC-1, AC-3, DC-1, AC-15
(SEE SECTION 11 FOR RELEVANT UTILIZATION CATEGORIES.)
RELAYS CAN BE ORDERED EITHER BY MAGNECRAFT OR STRUTHERS-DUNN PART NUMBERS LISTED BELOW COIL Measured @ 25C DUAL MARKED PART NUMBERS WIRING CONTACT CROSS REFERENCE NOMINAL NOMINAL NOMINAL CONFIGUTO Struthers-Dunn DIAG. INPUT RESISTANCE RATION FIG. W388B A283 (OHMS) POWER P O T T E R / B R U M F I E L D VOLTAGE AC OPERATED WITH BLOWOUT MAGNET (3 AMP CONTACTS) W388ABCPX-5 A283XBX69C-120A "A" DPDT 120 VAC 2.0VA KUEP-11A15-120
DC OPERATED WITH BLOWOUT MAGNET (3 AMP CONTACTS) W388BCPX-2 W388BCPX-3 W388BCPX-5 A283XBX69C-12D A283XBX69C-24D A283XBX69C-110D "A" "A" "A" DPDT DPDT DPDT 12 VDC 24VDC 110 VDC 120 472 10,000 1.2W 1.2W 1.2W KUEP-11D15-12 KUEP-11D15-24 KUEP-11D15-110
AC OPERATED WITH BLOWOUT MAGNET (10 AMP CONTACTS) W388ADBCPX-5 A283HXX69C-120A 'B' SPST-NO (DM) 120 VAC 2.OVA KUEP-3A15-120
DC OPERATED WITH BLOWOUT MAGNET (10 AMP CONTACTS) W388DBCPX-2 W388DBCPX-3 W388DBCPX-5 A283HXX69C-12D A283HXX69C-24D A283HXX69C-110D 'B' 'B' 'B' SPST-NO (DM) 12 VDC SPST-NO (DM) 24 VDC SPST-NO (DM) 110 VDC 120 472 10,000 1.2W 1.2W 1.2W KUEP-3D15-12 KUEP-3D15-24 KUEP-3D15-110
PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION.
SEE SECTION 10 FOR MATING SOCKETS PAGE 25 WEBSITE: www.magnecraft.com - EMAIL:info@magnecraft.com - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
CLASS
GENERAL SPECIFICATIONS
The Class 389 relays are high quality general purpose relays, designed to switch larger loads without increasing overall size. One, two and three pole relays are available with a choice of Indicator lamp, Push to test button and various contact combinations. Double make and double break styles are available only with a one pole style but is capable of switching larger loads and are especially well suited for switching motor loads. These relays are available in the 30 Amp contact range.
COMPLIES WITH REQUIREMENTS OF IEC STANDARDS 947-4-1 AND 947-5-1 LOW VOLTAGE DIRECTIVE Recognized Component mark for Canada and the United States.
389
*
MANUFACTURED UNDER QUALITY SYSTEM
IEC = INTERNATIONAL * ELECTROTECHNICAL COMMISSION
UL Recognized File No. E43641
C
US
ISO 9002 & QS 9000
FLANGE MOUNT
WIRING DIAGRAMS
Viewed from terminal end 1 1 4 7 A 2 5 8 3 6 9 B 1 4 7 A 2 5 8 3 6 9 B 1 4 7 A 2 5 8 3 6 9 B 4 3 6 4 6
A
B
A
B
SPDT
DPDT
3PDT
SPDT-NC-NO(DB-DM)
SPST-NO-(DM)
CLASS 389 DIELECTRIC WITHSTANDING VOLTAGES (VRMS) 1, 2 & 3 POLE STYLE RELAYS POINTS WHERE VOLTAGE IS APPLIED ACROSS OPEN CONTACTS POLE- TO- ADJACENT POLE COIL TO FRAME COIL TO CONTACTS CONTACT TO FRAME CONTACTS TO METAL MOUNTING PLATE ( COVER INSTALLED) COIL TO METAL MOUNTING PLATE (COVER INSTALLED) SPDT 1000 1600 2200 1600 2200 2200 DPDT 1000 2200 1600 2200 1600 2200 2200 3PDT 1000 1600 1600 1600 1600 1600 2200
CLASS 389D DIELECTRIC WITHSTANDING VOLTAGES VRMS) SPDT-NC-NO (DB-DM), SPST-NO - (DM) POINTS WHERE VOLTAGE IS APPLIED ACROSS OPEN CONTACTS COIL TO FRAME COIL TO CONTACTS CONTACT TO FRAME CONTACTS TO METAL MOUNTING PLATE ( COVER INSTALLED) COIL TO METAL MOUNTING PLATE (COVER INSTALLED) ENCLOSED STYLE 1500 1600 2200 1600 2200 2200
NEW!
* RELEVANT IEC CONTACT UTILIZATION CATEGORIES
AC-1, AC-3, DC-1, AC-15
(SEE SECTION 11 FOR RELEVANT UTILIZATION CATEGORIES.)
TOP FLANGE MOUNT
WEBSITE: www.magnecraft.com - EMAIL:info@magnecraft.com - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
PAGE 26
CLASS
389
GENERAL SPECIFICATIONS
SPECIFICATIONS CLASS 389 RELAYS
COIL Pull-in voltage: Dropout voltage: Coil resistance: Nominal power: Maximum coil dissipation: Duty: Insulation System: CONTACTS Contact material: Contact Gap: Contact resistance: TIMING Operate time, (excluding bounce): Release time, (excluding bounce): DIELECTRIC STRENGTH Insulation resistance: TEMPERATURE Operating: Storage: LIFE Electrical: Mechanical: MISCELLANEOUS Enclosure: Operating Position: Insulation material: Terminals: Weight:
80% of nominal voltage or less. for DC coils. 85% of nominal voltage or less for AC coils. 10% of nominal voltage or more. 10 % Measured at 25C 1.44 Watts for DC coils, 2VA to 3.5VA for AC coils Capability of DC coils 2.5 Watts max. Continuous Class "B" coil system. (130C per UL std. 1446).
1/4" silver cadmium oxide, gold flashed. .015 min. is standard. 50 Milliohms maximum initial resistance at rated current
20 milliseconds max.at nominal voltage. 20 milliseconds max.at nominal voltage.
1,000 Megohms min. @ 500 VDC
-30C to +50C (AC), -30C to +65C (DC) -30C to 100C
100,000 at rated load. 5 Million Operations no load
Clear Polycarbonate dust cover Any Molded plastic 1/4" x .032 Q.C. Terminals suitable for solder or Q.C. connectors, also available with Printed Circuit terminals. (.090 x .032) 3.3 oz.. (94 g approx. with cover).
ALSO AVAILABLE
The 300 series was developed as a 600 Volt relay that would accept 1/4" booted terminals. Its extra spacing permits contact gaps to 2 millimeters when required. This increases dielectric strength across open contacts to 2500 Volts RMS. Consult factory for details or additional information. 2.53 (64.29) 1.90Max. (48.4)
OPTIONAL
TOP FLANGE COVER IS AVAILABLE ON SPECIAL ORDER. CONSULT FACTORY.
1.41 (35.8)
1.40Max. (35.5)
.500 (12.7)
PAGE 27
WEBSITE: www.magnecraft.com - EMAIL:info@magnecraft.com - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
CLASS
GENERAL CONTACT RATINGS
Recognized Component mark for Canada and the United States.
389
UL Recognized File No. E43641
C
US
1, 2 & 3 POLE NEMA PILOT DUTY CONTACT RATINGS
MAXIMUM CURRENT, AMPERES THERMAL NEMA 120 VOLTS CONTINUOUS CONTACT 50/60Hz TEST CURRENT CODE MAKE BREAK DESIGNATION AMPERES A600 B300 B600 10 5 5 60 30 30 6.00 3.00 3.00 240 VOLTS 50/60Hz MAKE 30 15 15 BREAK 3.00 1.50 1.50 480 VOLTS 50/60Hz 600 VOLTS 50/60Hz BREAK 1.20 0.06 MAXIMUM VOLT-AMPERES MAKE 7200 3600 3600 BREAK 720 360 360
MAKE BREAK MAKE 15 0.75 1.50 0.75 12 6
CLASS 389 LOAD RATINGS
ENCLOSED STYLE 1, 2 and 3 POLE NO. OF POLES CURRENT OR HORSEPOWER 13A 20A 25A 5A 1HP 1-1/2HP 1HP 660VA 915VA 960VA 765VA B600 13A 20A 25A 5A 1HP 1-1/2HP 1HP 660VA 915VA 960VA 765VA B600 13A 15A 20A 20A **15A *10A 1/2HP 1HP 3/4HP 470VA 445VA B300 LOAD VOLTAGE 28 15 300 600 120 208/240 480/600 120 208 240 480/600 LOAD VOLTAGE FREQUENCY DC DC 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60Hz DC DC 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60Hz DC DC (NO) DC 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60Hz 50/60 Hz 50/60 Hz 50/60Hz TYPE OF LOAD RESISTIVE RESISTIVE RESISTIVE RESISTIVE MOTOR MOTOR MOTOR PILOT DUTY PILOT DUTY PILOT DUTY PILOT DUTY PILOT DUTY RESISTIVE RESISTIVE RESISTIVE RESISTIVE MOTOR MOTOR MOTOR PILOT DUTY PILOT DUTY PILOT DUTY PILOT DUTY PILOT DUTY RESISTIVE RESISTIVE RESISTIVE RESISTIVE RESISTIVE RESISTIVE MOTOR MOTOR MOTOR PILOT DUTY PILOT DUTY PILOT DUTY
CLASS 389D LOAD RATINGS
ENCLOSED CURRENT OR NO. OF POLES HORSEPOWER 1 P O L E 30A 30A 10A 1HP 1-1/2HP 765VA 915VA 960VA A600 LOAD VOLTAGE 28 300 600 120 200 thru 600 120 208 240,480,600 STYLE LOAD VOLTAGE FREQUENCY DC 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz TYPE OF LOAD RESISTIVE RESISTIVE RESISTIVE MOTOR MOTOR PILOT DUTY PILOT DUTY PILOT DUTY PILOT DUTY
1 P O L E
2 P O L E
28 15 300 600 120 208/240 480/600 120 208 240 460/600
CLASS 389 BALLAST LOAD RATINGS
NO. OF POLES 1 2 3 POLE POLE POLE ENCLOSED STYLE
3 P O L E
28 28 15 150 250 300 120/208/240 240 120 120/240 208
20 AMPS, 277VAC, 50/60Hz 20 AMPS, 277VAC, 50/60Hz 20 AMPS,150VAC, 50/60Hz 6-2/3 AMPS, 277VAC, 50/60Hz
DOUBLE BREAK DOUBLE MAKE (1 FORM "X" & "Z") 1 POLE 25 AMPS, 277VAC, 50/60Hz
Not CSA rated with ** are UL Appliance rated. All other ratings not so marked are industrial rated * CSA rating only, not UL
WEBSITE: www.magnecraft.com - EMAIL:info@magnecraft.com - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
PAGE 28
CLASS
389
CLASS 389D
SQUARE BASE, 30 AMP POWER RELAY
Recognized Component mark for Canada and the United States.
1/4" Q.C. MALE TAB TERMINALS FOR USE WITH FEMALE QUICK CONNECT TERMINALS OR SUITABLE FOR SOLDERING.
TOP FLANGE COVER AVAILABLE ON SPECIAL ORDER. CONSULT FACTORY
OPTIONAL INDICATOR LAMP AND PUSH TO TEST BUTTON AVAILABLE ON SPECIAL ORDER. MANUFACTURED UNDER QUALITY SYSTEM
UL Recognized File No. E43641
C
US
*
COMPLIES WITH REQUIREMENTS OF IEC STANDARDS 947-4-1 AND 947-5-1 LOW VOLTAGE DIRECTIVE
IEC = INTERNATIONAL * ELECTROTECHNICAL COMMISSION
ISO 9002 & QS 9000
OUTLINE DIMENSIONS
Dimensions shown in Inches and (millimeters). 2.50 (63.5) 2.90Max. (73.8) .250 x .032 (6.35 x .891) QC Terminals Typical
FLANGE COVER
1.53 Max. .625 Typ. (38.8) (15.8) .156 (3.9)
.187 (4.76)
1.90Max. (48.4)
1 4 2 5 8 3 6 9 B
1.40Max. (35.5)
7 A
.28 Typ. (7.1)
* RELEVANT IEC CONTACT UTILIZATION CATEGORIES
AC-1, AC-3, DC-1, AC-15
(SEE SECTION 11 FOR RELEVANT UTILIZATION CATEGORIES.)
PART NUMBERS AC OPERATED W389ADCX-4 W389ADCX-5 W389ADZCX-3 W389ADZCX-4 DC OPERATED W389DCX-2 W389DCX-3 W389DZCX-2 W389DZCX-3
CONTACT CONFIGURATION SPST-NO-(DM) SPST-NO-(DM) SPDT-NO-NC (DM-DB) SPDT-NO-NC (DM-DB)
CONTACT RATING
COIL Measured @ 25C CROSS REFERENCE NOMINAL NOMINAL TO NOMINAL INPUT RESISTANCE POTTER & BRUMFIELD POWER VOLTAGE (OHMS) 120 VAC 240VAC, 60Hz 220 VAC, 50Hz 24 VAC 2.75VA 2.75VA KUMP6A5G-24 3.75VA KUMP6A5G-120 120VAC 3.75VA KUMP3A5G-120 KUMP3A5G-240
30 AMP 30 AMP 30 AMP 30 AMP
SPST-NO-(DM) SPST-NO-(DM) SPDT-NO-NC (DM-DB) SPDT-NO-NC (DM-DB)
30 AMP 30 AMP 30 AMP 30 AMP
12 VDC 24 VDC 12 VDC 24VDC
100 400 100 400
1.44W 1.44W 1.44W
KUMP3D5G-12 KUMP3D5G-24 KUMP6D5G-12 KUMP6D5G-24
1.44W
EXCEPTION TO CROSS REFERENCE: MAGNECRAFT RELAYS ARE RATED AT 3O AMPS , P&B 15 AMPS PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION. SEE CLASS 389 GENERAL SPECIFICATIONS AND WIRING DIAGRAMS.
PAGE 29
WEBSITE: www.magnecraft.com - EMAIL:info@magnecraft.com - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
CLASS
SQUARE BASE, 25 AMP POWER RELAY
Recognized Component mark for Canada and the United States.
389
*
COMPLIES WITH REQUIREMENTS OF IEC STANDARDS 947-4-1 AND 947-5-1 LOW VOLTAGE DIRECTIVE
UL Recognized File No. E43641
C
US
CLASS 389 RELAY
1/4" MALE TAB TERMINALS FOR USE WITH FEMALE QUICK CONNECT TERMINALS OR SUITABLE FOR SOLDERING
TOP FLANGE COVER AVAILABLE ON SPECIAL ORDER. CONSULT FACTORY
OPTIONAL INDICATOR LAMP AND PUSH TO TEST BUTTON AVAILABLE ON SPECIAL ORDER. MANUFACTURED UNDER QUALITY SYSTEM
IEC = INTERNATIONAL * ELECTROTECHNICAL COMMISSION
OUTLINE DIMENSIONS
Dimensions shown are in INCH and (Millimeter) 2.90Max. .250 x .032 (73.8) (6.35 x .891) 2.50 QC Terminals Typical (63.5)
ISO 9002 & QS 9000
1.53 Max. .625 Typ. (38.8) (15.8) .156 (3.9) .187 (4.76) 1.90Max. (48.4)
1 4 2 5 8 3 6 9 B
1.40Max. (35.5)
7 A
.28 Typ. (7.1)
* RELEVANT IEC CONTACT UTILIZATION CATEGORIES
AC-1, AC-3, DC-1, AC-15
(SEE SECTION 11 FOR RELEVANT UTILIZATION CATEGORIES.)
PART NUMBERS
FLANGE COVER
AC OPERATED W389ACX-4 W389ACX-8 W389ACX-9 W389ACX-10 W389ACX-14 W389ACX-15 DC OPERATED W389CX-2 W389CX-3 W389CX-7 W389CX-8 W389CX-12 W389CX-13
CONTACT CONFIGURATION
CONTACT RATING
COIL Measured @ 25C NOMINAL NOMINAL NOMINAL INPUT RESISTANCE POWER VOLTAGE (OHMS) 120 VAC 24VAC 120 VAC 240 VAC, 60 Hz 220 VAC, 50 Hz 120 VAC 240 VAC. 60 Hz 220 VAC, 50 Hz 2.75VA 2.75VA 2.75VA 2.75VA 2.75VA 2.75VA
CROSS REFERENCE TO POTTER & BRUMFIELD
SPDT DPDT DPDT DPDT 3PDT 3PDT
25 AMP 25 AMP 25 AMP 25 AMP 20 AMP 20 AMP
KUHP5A51-120 KUHP11A51-120 KUHP11A51-120 KUHP11A51-120 -
SPDT SPDT DPDT DPDT 3PDT 3PDT
25 AMP 25 AMP 25 AMP 25 AMP 20 AMP 20 AMP
12 VDC 24 VDC 12VDC 24VDC 12 VDC 24 VDC
100 400 100 400 100 400
1.44W 1.44W 1.44W 1.44W 1.44W 1.44W
KUHP5D51-12 KUHP5D51-24 KUHP11D51-12 KUHP11D51-24 -
PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION. SEE CLASS 389 GENERAL SPECIFICATIONS AND WIRING DIAGRAMS.
WEBSITE: www.magnecraft.com - EMAIL:info@magnecraft.com - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
PAGE 30
CLASS
97
25 AMPS METAL ENCLOSED POWER RELAY
UL Recognized File No. E43641
CLASS 97 POWER RELAY
PLUG-IN OR SIDE STUD MOUNT
OUTLINE DIMENSIONS Dimensions shown in Inch & (Millimeter)
STUD MOUNT
1.60 (40.6) 1.52 (38.6) 0.40 (10.1) 8-32 Stud
3 Standoffs on Stud Mount Covers only. (Typical)
1.52 (38.6)
PLUG-IN, PLAIN COVER, NO STUD
1.52 (38.6)
2.06 Max. (52.3) 1.21 (30.7)
.310 (7.8) 1.56 (39.7)
3 4 5 6 7 3 1 2 4 8
.250 x .030 Q.C. Terminal (Typical)
1.56 (39.7)
.110 x .010 Q.C. Coil Terminal (Typical)
1.56 (39.7)
1 7 8 2 9 10
1.56 (39.7)
9 10
5 6
COIL Measured @ 25C Nominal Nominal Nominal Input Resistance Power Voltage (Ohms) STUD MOUNTING STYLE W97ACSX-3 120 VAC 8 VA W97ACSX-4 240 VAC, 60 HZ 8 VA 220 VAC, 50 HZ W97CSX-1 12 VDC 50 2.5 W W97CSX-2 24 VDC 200 2.5 W PART NUMBERS PLAIN COVER, PLUG-IN (NO STUD) W97ACPX-2 W97ACPX-3 W97ACPX-4 W97CPX-1 W97CPX-2 24 VAC 120 VAC 240 VAC, 60 HZ 220 VAC, 50 HZ 12 VDC 24 VDC 50 200 8 VA 8 VA 8 VA 2.5 W 2.5 W
WIRING SCHEMATIC Viewed from Terminal End
3 4 5 6
1
2
7
8
9
10
PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION.
PAGE 31
WEBSITE: www.magnecraft.com - EMAIL:info@magnecraft.com - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
METAL ENCLOSED, 25 AMP - 2 FORM "Z" CONTACTS
CLASS
97
SPECIFICATIONS FOR CLASS 97
COIL Pull-in Voltage: Dropout Voltage: Max. allowed voltage: Maximum Power Minimum Power: Duty Resistance CONTACTS Contact Configuration: Contact Material: Contact Resistance: Contact Rating: AC, 85% of Nominal Voltage or less DC, 75% of Nominal Voltage or less 110% of nominal voltage 3 Watts 1.6 Watts Continuous 10%
DPDT-NC-NO (DB-DM) Silver Alloy 50 Milliohms max. (Initial) 25 Amps @ 240 VAC Resistive. 25 Amps @ 277 VAC Resistive. 1 HP @ 120 VAC, 2Hp @ 240 VAC 25 Amps Resistive @ 28 VDC. 35 mS Max. @ Nominal Voltage. 35mS Max. @ Nominal Voltage.
TIMING Operate Time: Release Time: DIELECTRIC STRENGTH Coil to Contacts: Across Open Contacts: Pole to Pole: Contact to Frame: Insulation Resistance: TEMPERATURE Operating: VIBRATION RESISTANCE Functional: SHOCK RESISTANCE Functional: LIFE EXPECTANCY Mechanical (No Load): Electrical (Rated Load): Max. Cycle Rate: MISCELLANEOUS Terminals:
2000 V rms 1500 V rms 2000 V rms 2000 V rms 500 VDC Exceeds 100 Megohms min.
-35C to +70C @ Rated Operation.
5g's; 10 to 55 Hz,
10 g's
1 Million Operations 100,000 Operations 1800 per hour
Enclosure: Operating Position: Weight:
All Terminals on Stud mounted relays are 1/4" x .032 Quick Connect Tabs. Plug-in relays have 1/4" x .032 Quick Connect Tabs and .110 Taper Coil Terminals. Plated Steel Any 259.4 grams
SEE SECTION 10 FOR MATING SOCKETS WEBSITE: www.magnecraft.com - EMAIL:info@magnecraft.com - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100 PAGE 32
SERIES
219
300 VOLT GENERAL PURPOSE PLUG-IN RELAY
THE SERIES 219 GENERAL PURPOSE INDUSTRIAL PLUG-IN RELAYS FEATURE 12 PIN AND 14 PIN BASES. THE COIL IS ENCAPSULATED FOR PROTECTION. NUCLEAR QUALIFIED VERSIONS ARE AVAILABLE. CONSULT FACTORY. UL Recognized
File No. E13224
OPTIONAL MANUAL ACTUATOR 2.625 (66.6) .250 (6.35)
WIRING DIAGRAMS BOTTOM VIEW
219XBXP (DPDT ) 6 1
2.593 (65.5) 3.406 (86.5) 7 12
219BBXP (DPDT + 2 N.O.) LOCKING CLIP .435 (11) 6 1
7
12
0.10 Dia. x .435 (2.54 x 11) Typical of all Pin Dimensions 12
1
2 11
3 10
4 9
5 8
6 7
1.468 (37.2) 219ABAP (DPDT + 1NO & 1 NC )
MODELS AVAILABLE
12 PIN CONTACTS 14 PIN
219XDXP 219FXXP 219DXBP
6
1
CONTACTS
4PDT 6P-NO 4P-NO + 2P-NC 7 12
DPDT + 2 NO 219BBXP DPDT 219XBXP 219ABAP DPDT + 1 NO & 1 NC
Make before break and other Contact configurations available limited only by the number of terminal pins.Contact Factory.
OPTIONAL MANUAL ACTUATOR 3.062 (77.77) .250 (6.35) 7 219FXXP (6P-NO ) 1
2.593 (65.5) 3.406 (86.5)
8
14
219XDXP (4PDT ) LOCKING CLIP .435 (11) 7 1
8
14
14 1
13 2
12 11 3 4
10 5
9 6
8 7
1.468 (37.2)
219DXBP (4P-NO + 2P-NC ) 7 1
0.10 Dia. x .435 (2.54 x 11) Typical of all Pin Dimensions
8
14
PAGE 33
WEBSITE: www.magnecraft.com - EMAIL:info@magnecraft.com - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
SERIES
300 VOLT GENERAL PURPOSE PLUG-IN RELAY
219 GENERAL SPECIFICATIONS
COIL Pull-in, min. AC Pull-in min. DC Overvoltage, max. CONTACTS Contact Material: TIMING Operate Time: Release Time: DIELECTRIC STRENGTH All Mutually Insulated Points: Insulation : TEMPERATURE Rated Operation: 85% of Nominal Voltage 80 % of Nominal Voltage 110% of nominal, voltage Silver Cadmium Oxide, Gold diffused (Standard) 25 mS Max. @ Nominal Voltage. 20 mS Max. @ Nominal Voltage.
219
1500 V rms 1/4" over surface, 1/8" thru Air
-10C to +60C
LIFE EXPECTANCY Mechanical: Electrical: MISCELLANEOUS Enclosure: Operating Position: Weight: COIL SPECIFICATIONS @ 25C
AC RELAYS 50/60 HZ (COIL DATA @ 60HZ Voltage
10 Million Operations no load 100,000 Operations @ Rated Load.
Clear polycarbonate. Vertical, Contacts Up 8.5 oz. (241 g) approx. CONTACT RATINGS BREAK MAKE CARRY RESISTIVE INDUCTIVE
30A 30A 30A 30A 30A 10A 10A 10A 10A 10A 10A 10A 5A 10A 0.5A 10A 3A 1A 3A 0.1A
DC RELAYS, 1.8 WATTS (2.5 W @ 125VDC)
Nominal Voltage 6 12 24 120 240
Resistance Milliamperes Impedance Nominal Resistance Milliamperes Ohms Cold Hot Voltage Ohms Cold Hot Ohms 10% 10% 1.1 6 15.5 1500 840 385 304 7.2 4.2 12 63.5 189 147 750 410 27 15.5 24 (28)* 250 77 375 200 96 120 540 40 32 375 62 86 75 2700 2100 17 16 32 20 13,400 115/125* 6200
VOLTS
24 VDC 120 VAC 240 VAC 28 VDC 125 VDC
For versions with suffix "69" Permanent Magnet Blowouts
125 VDC 125 VDC 250 VDC 250 VDC SM DM SM DM 30A 30A 30A 30A 10A 10A 10A 10A 1.5A 4A 0.5A 1.5A 0.5A 1.5A 150 mA 0.5A
* Note: Stock 24 Vdc and 115 Vac relays have nameplates stamped 24-28 and 115-125 Vdc respectively. These relays operate at 80% of the lower voltages and operate within allowable temperature rises at higher voltages. 250 Vdc - Use 125 Vdc relay and series resistor (6000 , 5 W) not supplied.
Struthers-Dunn
ORDERING CODE Typical Type No.
219 XBX
P L -24D
Series 219 Industrial plug-in style Contact Arrangements XBX (DPDT) ABA (DPDT + 1 Pole-NO & 1 Pole NC) BBX (2 Pole-NO & DPDT) XDX (4 PDT) FXX (6 Pole-NO) DXB (4 Pole-NO & 2 Pole-NC) Standard Features Polycarbonate Cover- CODE "P" Optional Features Indicator Lamp - CODE "L" Manual Actuator- CODE "M" 130C Coil - CODE "U" Bifurcated Contacts - CODE "33" Perm. Magnet Blowout- CODE "69" Coil Voltage AC: 6, 12, 24, 120, 240 (Add "A") DC: 6, 12, (24-28), 32, 115/125 (Add "D") Coil Voltages & Frequencies must be specified.
SEE SECTION 10 FOR MATING SOCKETS PAGE 34
WEBSITE: www.magnecraft.com - EMAIL:info@magnecraft.com - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
RSX 1800 INDUSTRIAL PLUG-IN ALARM RELAY 5 AMP, 2 POLE
The RSX1800 Series Alarm Relay consists of a pair of 2 pole or 3 pole relays enclosed in a clear plastic cover. Wired to a 12 Pin Industrial plug. The relay is wired so that it performs the basic functions of Interfacing between a alarm point and an alarm light and/or an acoustic sounding device. The RSX1800 operates from a normally closed trouble contact, while the RSX1800Z operates from a normally open trouble contact. Either a sustained or momentary alarm condition will energize the relay when signalled by an external trouble contact. The Alarm can be allowed to continue until the trouble has been corrected, at which time it automatically resets.
SERIES
2.625 (66.6)
2.593 (65.5) 3.406 (86.5)
0.10 Dia. x .435 (2.54 x 11) Typical of all Pin Dimensions LOCKING CLIP .435 (11)
12 1
11 2
10 3
9 4
8 5
7 6
1.468 (37.2)
COIL DATA
Measured at 25C
AC Coils, 50/60Hz AC Coils, 50/60Hz Ohms mA Volts Volts Ohms mA 6 6 35 170 10.7 200 12 12 150 80 41.1 100 24 24 59 560 43 170 120 10 115-125 11,000 10.5 4500
Struthers-Dunn
ORDERING CODE Typical Type No.
RSX1800 S 120A
Series 219 Industrial plug-in style Alarm relay 5 Amp, 2 Pole Design for Trouble Contacts Operate from N.C. trouble contact- CODE S* Operate from N.O. Trouble contact- CODE Z* Coil Voltage AC: 6, 12, 24, 120, (Add "A") DC: 6, 12, 24 110-125 (Add "D") * Codes "S" & "Z" are 120 VAC only. All other codes are "AD" for NC input or "ZZ" for NO input.
SEE SECTION 10 FOR MATING SOCKETS PAGE 35 WEBSITE: www.magnecraft.com - EMAIL:info@magnecraft.com - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
SERIES
INDUSTRIAL PLUG-IN ALARM RELAY 5 AMP, 2 POLE RSX 1800
GENERAL SPECIFICATIONS
CONTACTS Contact Material: Rating: Silver Cadmium Oxide. 5 AMP, 120Vac/30Vdc Resistive 20 mS Max. @ Nominal Voltage. 25 Milliseconds max. 20 milliseconds max.
LEGEND
K1 - Alarm/Silencing Relay. K2 - Alarm/Silencing Relay. A - Horn & optional Flasher. TT - Lamp test (optional). L1 - Line voltage. R - Reset (optional for manual reset only. S - Horn Silence (acknowledge). F - Flasher (Optional). N - Neutral. Relays are supplied only with the items and wiring shown within the rectangles in schematics. NOTE: For additional alarms, jumper to like terminals as shown.
TIMING Operate Time: Release Time: DIELECTRIC STRENGTH Across open contacts: Between all mutually insulated current carrying parts: TEMPERATURE Rated Operation: LIFE EXPECTANCY Mechanical: Electrical: MISCELLANEOUS Enclosure: Operating Position: Weight:
500 V rms
1500 V rms
-10C to +70C
20 Million Operations no load 500,000 Operations @ Rated Load.
Clear polycarbonate. Any 8.8 oz (250 g) approx.
* OMIT for RESET (RSX1800Z) MANUAL RESET (RSX1800S) Manual (Push-button) K1 K2 Flasher Horn Reset Sequence. 1- Normal ON ON OFF OFF 2- Alarm OFF ON ON ON 3- Acknowledge OFF OFF OFF OFF 4- Alarm Contact Recloses OFF OFF OFF OFF 5- Reset ON ON OFF OFF 6- Lamp Test ON ON OFF OFF Lamp OFF Flashing ON ON OFF ON AUTOMATIC RESET (RSX1800S) Automatic Reset Sequence. 1- Normal 2- Alarm 3- Acknowledge 4- Alarm Contact Recloses 5- Lamp Out K1 K2 Flasher Horn Lamp ON ON OFF OFF OFF OFF ON ON ON Flashing OFF OFF OFF OFF ON On On ON ON OFF OFF OFF OFF OFF ON Automatic or Manual K1 K2 Flasher Horn Lamp 1- Normal OFF ON OFF OFF OFF 2- Alarm ON ON ON ON Flashing 3- Acknowledge ON OFF OFF OFF ON 4- Trouble Contact Reopens. Auto reset OFF ON OFF OFF OFF Manual reset ON OFF OFF OFF ON 5- Reset OFF ON OFF OFF OFF 6- Lamp Test OFF ON OFF OFF ON * External Jumper supplied be Customer. AUTO or MANUAL RESET
RSX1800Z
N K1 1 K2 7 Acknowledge Horn 4 K1 K1 12 A Alarm Lamp DS N L1 Flasher Contact Lamp Test SF T K2 K2 9 5 K2 K1 K1 K2 3 2 6 K1 K2 K2 4 K1 12 A N L1 R Alarm Lamp DS Flasher Motor M L1 Reset No trouble contact 7 8 Acknowledge Flasher Contact Lamp Test K2 K2 9 5 K2 K1 K1 K2 3 2 6 SFT K1 K2 K2 4 K1 12 A N Alarm Lamp DS K1 K1 1 Flasher Motor M N
MANUAL RESET
L1
AUTOMATIC RESET
N L1
RSX1800S
NC Alarm contact K1 8 K2 7 K2 Acknowledge Flasher Contact Lamp Test 5 K2 K1 K1 K2 3 2 6 RS F T K2 K2 K2 9 K1 1
RSX1800S
External Jumper K1 8
Reset
Flasher Motor M
NC Alarm cont.
Horn
Horn
L1
WEBSITE: www.magnecraft.com - EMAIL:info@magnecraft.com - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
PAGE 36
CLASS
21
FLASH TRANSFER RELAY SWITCHES TUNGSTEN LOADS
CLASS 21
PLUG-IN BASE WITH POLARIZING PIN DPDT CONTACT CONFIGURATION SWITCHES TUNGSTEN LAMP LOADS UP TO 20 AMPS
MEETS NEMA STD. TS 2- 1992 APPROVED BY D.O.T FOR: California Minnesota Georgia New York Illinois Texas Oregon Colorado Missouri
Recognized Component mark for Canada and the United States.
UL Recognized File No. E43641
C
US
OUTLINE DIMENSIONS
DIMENSIONS SHOWN ARE IN INCHES AND (MILLIMETERS)
2.84 Max. (72.2) .500 (12.7) 1.85 Max. (46.9) .060 (1.5)
Polarizing Pin
.250 Typ. (6.35)
WIRING DIAGRAM
VIEWED FROM PIN END 7 8
2.12. (53.9)
2.47 Max. (62.7)
5
6
.437 Typ. (11.09)
3
4
3.90 Max. (99.2)
.600 (15.4) 1.00 (25.4)
.500 Typ. (12.7)
v1
2
Rectified Coil
SPECIFICATIONS CLASS 21 RELAY
COIL Pull-in Voltage: Dropout Voltage: Coil Insulation : AC: 70% of Nominal @ 20C or less 10% of Nominal Voltage or more Class "B" System (130C) per UL 1446 DIELECTRIC STRENGTH Across open contacts 500 V rms Contact to Coil: 1500 V rms Contact to Frame: 1500 V rms TEMPERATURE Operating: LIFE EXPECTANCY Electrical: Mechanical: MISCELLANEOUS Enclosure: Operating Position: Weight: -40C to +84C 200,000 Operations min. at 20 Amps Tungsten, 120VAC. 5 Million Operations MIN. (No Load) Clear Polycarbonate Vertical contacts up or horizontal 7.2 oz.. 204.7 Grams
CONTACTS Contact Material: Silver alloy 3/8" dia. Contact Configuration: DPDT Contact Rating: 20Amps, 28VDC (Resistive). 1-1/2 HP, 120VAC (Motor) 2HP, 240VAC (Motor) 20Amps, 120VAC (Tungsten Lamp) 10Amps, 240VAC (Tungsten Lamp)
Dual Marked Part Number W21ACPX-2 /W21ACPXD-5
Contact Configuration DPDT
Coil Measured at 25C Nominal Voltage Nominal Power 120VAC 4.0 VA
Type
* Rectified
* Rectified type coil provides:
1. Chatter Free operation in Brownout conditions down to 85VAC and will not overheat up to 130VAC. 2. Less Power consumption and less Heating. PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION.
PAGE 37
WEBSITE: www.magnecraft.com - EMAIL:info@magnecraft.com - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
CLASS
10 AMP, HERMETICALLY SEALED, STEEL CAN RELAY
CLASS 88HP
8 OR 11 PIN OCTAL BASE HERMETICALLY SEALED STEEL CAN Enclosure is filled with dry nitrogen,solder sealed and then electronically leak checked to prevent contamination of Internal parts. The case is painted gray to protect against the elements.
WIRING DIAGRAM
VIEWED FROM PIN END
88HP
CONTACT RATINGS TABLE
POLES 2 POLE 3 POLE 120 VAC 12 AMP 1/3 HP 10 AMP 1/3 HP 240 VAC 8 AMP 1/2 HP 6 AMP 1.2 HP 28 VDC 10 AMP
10 AMP
SPECIFICATIONS CLASS 88HP RELAY
DPDT 3PDT
COIL Pull-in voltage: Dropout: Coil resistance Nominal power: Max.coil Dissipation: Duty: CONTACTS Contact material: Contact resistance: TIMING Operate time: Release time: DIELECTRIC STRENGTH Contacts to coil: Across open contacts: Pole to pole Contacts to frame: Insulation resistance: TEMPERATURE Operating: Storage: SHOCK RESISTANCE Operating: Non operating: VIBRATION RESISTANCE Operating: Non operating: MISCELLANEOUS Enclosure:
OUTLINE DIMENSIONS
Dimensions are shown in Inch and (Millimeter).
1.53 (38.8)
80% of nominal voltage or less. For DC coils 85% of nominal voltage or less. For AC coils. 10% of nominal voltage or more. 10 % measured @ 25 C 1.5 Watts for DC coils, 3VA for AC coils DC coils 3.0 Watts max. Continuous 3/16" silver cadmium oxide, gold flashed. 50 Milliohms maximum initial resistance at rated current 25mS or less at nominal voltage. 20mS or less at nominal Voltage. 1500 V rms 1000 V rms 1500 V rms 1500 V rms 10,000 megohms min. @ 500 VDC -10C to +50C (AC), -10C to +60C (DC) -30C to 105C 5 G's 20 G's 5 G's, 10 Hz to 55 Hz 5 G's, 10 Hz to 55 Hz Hermetically Sealed Steel Can with octal plug. 8 or 11 pin octal plug-in Any 5 ozs. 141.7 g approx.
2.03 (51.5)
1.68 (42.8)
Terminals Operating Position: Weight:.
CONTACT NO. OF PINS CONFIGUOCTAL PART NUMBERS RATION STYLE AC OPERATED 50/60Hz Operation. 8 PIN W88AHPX-24 DPDT 11 PIN W88AHPX-36 3PDT DC OPERATED W88HPX-33 W88HPX-34 W88HPX-51 DPDT DPDT 3PDT 8 PIN 8 PIN 11PIN
COIL Measured @ 25C CROSS REFERENCE NOMINAL NOMINAL TO NOMINAL INPUT RESISTANCE POWER POTTER & BRUMFIELD* VOLTAGE (OHMS) 120VAC 120VAC 3.0VA 3.0VA KR11AGE (or GF) 120 KR14AGE (or GF) 120
12 VDC 24 VDC 24 VDC
100 400 400
1.5W 1.5W 1.5W
KR11DGE (or GF) 12 KR11DGE (or GF) 24 KR14DGE (or GF) 24
PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION
SPDT and other special contact combinations along with other coil voltages up to 240VAC are available. Consult Factory.
* GF = GOLD FLASHED
SEE SECTION 10 FOR MATING SOCKETS WEBSITE: www.magnecraft.com - EMAIL:info@magnecraft.com - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100 PAGE 38
Page 39
SECTION
2
2
PRINTED CIRCUIT BOARD RELAYS 1 TO 30 AMPERES
Magnecraft
Struthers-Dunn
HI-CURRENT P.C. BOARD RELAYS
RELAY SERIES 276 90 91
Pending
FEATURES
SUBMINIATURE EPOXY SEALED IMMERSION CLEANABLE STANDARD 0.1 GRID PATTERN SINGLE SIDE STABLE DESIGN 5KV SURGE RESISTANCE COIL TO FRAME. MEETS 4mm INTERNATIONAL SPACING COIL TO CONTACT.
EPOXY SEALED IMMERSION CLEANABLE. STANDARD 0.1 GRID PATTERN CLASS "B" OR "F" INSULATION SYSTEM MEETS UL 508 & UL 873 SPACING
EPOXY SEALED IMMERSION CLEANABLE. P.C. BOARD OR FLANGE MOUNT STYLES. CLASS "F" INSULATION SYSTEM. SPADE TERMINALS ACCEPT 1/4" Q.C. CONNECT TERMINALS. & 3/16'" COIL Q.C. TERMINALS.
CONTACT DATA
CONTACT
CONFIGURATION:
SPST-NO, SPDT (SPST-NO) 10A, 250 VAC/30 VDC (SPDT) 7 A, 250 VAC/30 VDC
SPST-NO
SPDT
SPST-NO
SPDT
MAXIMUM ALLOWABLE CONTACT LOAD:
30A, 240 VAC 20 A 240 VAC (NO) 20A, 30 VDC 15 A,240 VAC (NC) 10A, 30 VDC
30A, 240 VAC 20 A 240 VAC (NO) 20A, 30 VDC 15 A,240 VAC (NC) 10A, 30 VDC
CONTACT CONTACT
MATERIAL: RESISTANCE:
SILVER ALLOY 100 MILLIOHMS (INITIAL)
SILVER CADMIUM OXIDE 50 MILLIOHMS (INITIAL)
SILVER CADMIUM OXIDE 50 MILLIOHMS (INITIAL)
INSULATION CHARACTERISTICS
DIELECTRIC STRENGTH 2000 V rms NOT AVAILABLE 5, 6, 12, & 24VDC MILLIWATTS 1500 V rms NOT AVAILABLE 5, 12, 24 & 110 VDC MILLIWATTS 2500 V rms 24, 120 & 240 VAC NOT AVAILABLE 2 VA -
COIL DATA
AC - VOLTAGE: DC - VOLTAGE: POWER: VA,: (AC) WATTS,: (DC)
200
930
GENERAL DATA
AMBIENT TEMPERATURE OPERATIONAL: STORAGE: TIMING VALUES OPERATE: RELEASE: LIFE MECHANICAL: ELECTRICAL: - 40 C to + 70 C - 55 C to + 105 C - 55 C to + 130 C 15 MILLISECONDS 10 MILLISECONDS - 55 C to + 85 C - 55 C to + 130 C 20 MILLISECONDS 20 MILLISECONDS
10 MILLISECONDS 10 MILLISECONDS
20 MILLION OPERATIONS 100,000 OPERATIONS H W L .394 X .50 X .787
10 MILLION OPERATIONS 100,000 OPERATIONS H W L .805 X 1.08 X 1.30 C US
10 MILLION OPERATIONS 100,000 OPERATIONS H W L 1.10 X 1.08 X 1.27
DIMENSIONS APPROVALS PAGE NUMBER
PAGE 44
PAGE 45, 46
PAGE 47,48 PAGE 40
WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
Magnecraft
Struthers-Dunn
HI-CURRENT & MICRO MINIATURE P.C. RELAYS
RELAY SERIES 9A
NEW!
NEW!
92
7
FEATURES
EPOXY SEALED IMMERSION CLEANABLE WITH TAPE SEAL. P.C. BOARD OR FLANGE MOUNT STYLES. CLASS "F" INSULATION SYSTEM. SPADE TERMINALS ACCEPT INSULATED 1/4" Q.C. CONNECT TERMINALS. & 3/16'" COIL Q.C.TERMINALS.
EPOXY SEALED IMMERSION CLEANABLE WITH TAPE SEAL. PC BOARD OR FLANGE MOUNT STYLES. CLASS "F" INSULATION SYSTEM. 1/4" SPADE TERMINALS ACCEPT 1/4' Q.C. CONNECTORS.
MICRO MINIATURE SIZE CONFORMS TO FCC PART 68.302, 1500V SURGE RESISTANCE, FCC 68.304 1000V DIELECTRIC STRENGTH. EXCELLENT R.F. SWITCHING CHARACTERISTICS HIGH SHOCK & VIBRATION RESISTANCE PC BOARD MOUNTING ON 0.1 GRID PATTERN 94V-0 PLASTIC, EPOXY SEALED
CONTACT DATA
CONTACT
CONFIGURATION:
SPST-NO 30A, 240 VAC 20A, 30 VDC
SPDT 20 A 240 VAC 20A, 28 VDC (NO) 15A,240 VAC 10A, 28 VDC (NC)
SPST-NO 30A, 277 VAC 20A, 28 VDC
DPDT 30A, 277 VAC 20A, 28 VDC (NO) 3A, 277 VAC 3A, 28 VDC (NC)
SPDT, DPDT
MAXIMUM ALLOWABLE CONTACT LOAD:
2 A, 24 VDC 1 A, 100 VAC (DPDT) 2A, 120 VAC (SPDT) 50uA, 50mV MIN.
CONTACT CONTACT
MATERIAL: RESISTANCE:
SILVER CADMIUM OXIDE 75 MILLIOHMS (INITIAL)
SILVER CADMIUM OXIDE 100 MILLIOHMS (INITIAL)
GOLD CLAD SILVER PALLADIUM CROSS BAR 50 MILLIOHMS, (INITIAL)
INSULATION CHARACTERISTICS
DIELECTRIC STRENGTH 2500 V rms NOT AVAILABLE 5, 12, 24 48 & 110 VDC 2500 V rms 24, 120 & 240 VAC 12, 24 48 & 110 VDC 4 VA 1.7 WATTS 500 V rms NOT AVAILABLE 5, 12, & 24 VDC 330-370 MILLIWATTS
COIL DATA
AC - VOLTAGE: DC - VOLTAGE: POWER: VA,: (AC) WATTS,: (DC)
1 WATT
GENERAL DATA
AMBIENT TEMPERATURE OPERATIONAL: STORAGE: TIMING VALUES OPERATE: RELEASE: LIFE MECHANICAL: ELECTRICAL: - 55 C to + 85 C - 55 C to + 130 C 15 MILLISECONDS 15 MILLISECONDS DC,- 40 C to + 85C -AC,- +65C - 35 C to + 70 C
15 MILLISECONDS 10 MILLISECONDS
4.0 MILLISECONDS 5.0 MILLISECONDS
10 MILLION OPERATIONS 100,000 OPERATIONS H W L 1.10 X 1.08 X 1.27 C US
5 MILLION OPERATIONS 100,000 OPERATIONS H W L
100 MILLION OPERATIONS 100,000 OPERATIONS H W L
DIMENSIONS APPROVALS PAGE NUMBER PAGE 41
1.10 X 1.36 X 1.27 C US
.428 X .410 X .410 C US
PAGE 49, 50
PAGE 51, 52
PAGE 53, 54
WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
Magnecraft
Struthers-Dunn
MINIATURE P.C. BOARD RELAYS
60 178 49
MINIATURE SIZE CONFORMS TO FCC PART 68.302, 1500V SURGE RESISTANCE, FCC 68.304 1000V DIELECTRIC STRENGTH. EXCELLENT R.F. SWITCHING CHARACTERISTICS HIGH SHOCK & VIBRATION RESISTANCE PC BOARD MOUNTING ON 0.1 GRID PATTERN.
MINIATURE EPOXY SEALED. P.C. BOARD MOUNTING. SWITCHES UP TO 12 AMP LOADS. CLASS "B" OR "F" INSULATION SYSTEM IMMERSION CLEANABLE. DISPLACES APPROXIMATELY .43 CUBIC INCH.
DUST COVERED DISPLACES APPROXIMATELY 1.1 CUBIC INCH. VARIETY OF MOUNTING CONFIGURATIONS. TV-5 RATINGS AVAILABLE.
SPDT, DPDT 2 A, 24 VDC 1 A, 100 VAC (DPDT) 2A, 120VAC )SPDT) 50uA, 50mV MIN.
SPDT 5 AMP @ 125/250VAC, 30VDC (CLASS 178RE1-) 12 AMP @ 120VAC, 28VDC 10AMP @ 125/250 VAC, 30 VDC (CLASS 178URE1-)
SPDT 3 AMPS @ 120 VAC/ 28 VDC 5 & 10 AMP @ 240VAC/28VDC
GOLD CLAD SILVER PALLADIUM CROSS BAR 50 MILLIOHMS MAX (INITIAL)
SILVER CADMIUM OXIDE 100 MILLIOHMS (INITIAL)
SILVER, GOLD PLATED, SILVER CADMIUM OXIDE 100 MILLIOHMS (INITIAL)
500 V rms NOT AVAILABLE 5, 12, & 24 VDC 330-370 MILLIWATTS
1500 V rms NOT AVAILABLE 5, 12, & 24 VDC
1500 V rms NOT AVAILABLE 3, 5, 6, 12, & 24 VDC
400
MILLIWATTS
400 MILLIWATTS
- 35 C to + 70 C
- 40 C to +70 C (272)
- 55 C to + 85 C - 55 C to + 130 C 10 MILLISECONDS 7 MILLISECONDS
4.0 5.0
MILLISECONDS MILLISECONDS
20 MILLISECONDS 10 MILLISECONDS
100 MILLION OPERATIONS 100,000 OPERATIONS H W L
10 MILLION OPERATIONS 100,000 OPERATIONS H W L
50 MILLION OPERATIONS 100,000 OPERATIONS H W L 1.14 X .759 X 1.25
.570 X .895 X 1.10 C US
.620 X .650 X .890 C US
PAGE 55, 56
PAGE 57, 58
PAGE 59 , 60 PAGE 42
WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
Magnecraft
Struthers-Dunn
MINIATURE P.C. BOARD RELAYS
RELAY SERIES 76
NEW!
1330 & 1335
SEE SECTION 10 FOR MATING SOCKETS
FEATURES
EPOXY SEALED IMMERSION CLEANABLE. MEETS 8 MILLIMETER SPACING COIL TO CONTACTS MEETS 4KV DIELECTRIC WITHSTANDING VOLTAGE.
MINIATURE SIZE ENCLOSED SEE THRU COVER WITH P.C. TERMINALS. AC OR DC OPERATION 5 AMP RESISTIVE OR 3 AMP INDUCTIVE SWITCHING.
CONTACT DATA
CONTACT
CONFIGURATION:
SPDT, DPDT 10 AMPS @ 250 VAC/ 30 VDC
SPDT 16AMPS @ 240 VAC/ 24 VDC
DPDT UL RATED - 5A, 120VAC, NON UL RATED - 5A, 30 VDC 3A, 120VAC INDUCTIVE. 1/8 HP, 120 VAC
MAXIMUM ALLOWABLE CONTACT LOAD:
CONTACT CONTACT
MATERIAL: RESISTANCE:
SILVER CADMIUM OXIDE 50 MILLIOHMS (INITIAL)
SILVER CADMIUM OXIDE 100 MILLIOHMS MAX. (INITIAL) 1500 V rms 24, 120 VAC 12, 24 VDC 1.2 VA 1.2 W
INSULATION CHARACTERISTICS
DIELECTRIC STRENGTH
4000 V rms SPECIAL ORDER 5,6, 12, 24 & 48 VDC
COIL DATA
AC - VOLTAGE: DC - VOLTAGE: POWER: VA,: (AC) WATTS,: (DC)
520
MILLIWATTS
GENERAL DATA
AMBIENT TEMPERATURE OPERATIONAL: STORAGE: TIMING VALUES OPERATE: RELEASE: LIFE MECHANICAL: ELECTRICAL: - 20 C to + 70 C - 45 C to + 70 C
15 MILLISECONDS 10 MILLISECONDS
20 20
MILLISECONDS MILLISECONDS
20 MILLION OPERATIONS 150,000 OPERATIONS H W L .811 X .512 X 1.14 C
AC, 50 M. DC, 100M OPERATIONS 100,000 OPERATIONS H W L
DIMENSIONS APPROVALS PAGE NUMBER PAGE 43
.905 X .728 X 1.07 US LIMITED RATINGS
PAGE 61, 62
PAGE 63
WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
MINIATURE POWER RELAY 10 AMP, P.C. MOUNTABLE
ACTUAL SIZE
SERIES
276
SERIES 276
DTL COMPATIBLE SINGLE SIDE STABLE DESIGN 5KV SURGE RESISTANCE COIL TO CONTACT MEETS INTERNATIONAL SPACING -4 mm COIL TO CONTACT SPECIFICATIONS SERIES 276
COIL Pull-in Voltage: Dropout Voltage: Max. allowed voltage: Coil Resistance: Nominal Power: CONTACTS Contact Material: Contact Resistance: TIMING Operate Time: Release Time: DIELECTRIC STRENGTH Contacts to Coil: Across open contacts: Surge voltage resistance: Insulation Resistance:
75% of Nominal Voltage or less 10% of nominal voltage or more 110% of nominal voltage. 10% 200mW Approx. Silver Alloy 100 Milliohms initial @ 6VDC, 1 Amp 10 mS Max. @ Nominal Voltage. 10 mS Max. @ Nominal Voltage. 2000 V rms 1000 V rms 5000 V rms between coil and contacts 500 VDC Exceeds 1000 Megohms min..
TEMPERATURE Operating:: VIBRATION RESISTANCE Functional: SHOCK RESISTANCE Functional: LIFE Electrical (Rated Load): Mechanical ( No Load): MISCELLANEOUS Operating Position: Enclosure: Weight:
-40C to +70C 10g's 10 to 55Hz, .06" DA 100g's no damage 100,000 Operations 20 Million Operations Any Plastic Cover, Epoxy sealed, 0.2 oz. ( 5.5 grams) approx.
LOW LEVEL LOADS: NOT SUITABLE BELOW 20 WATTS
OUTLINE DIMENSIONS Dimensions shown are in "Inch" and ( Millimeter) WIRING DIAGRAM BOTTOM VIEW CIRCUIT BOARD SPACING Layout shown is on a 0.100 Grid BOTTOM VIEW
.787 Max. (20)
SPDT
+
.051 Dia. (1.3) 5 Places 0.50 (12.7)
SPST-NO
+
.394 Max. (10)
.138 (3.5)
.015 x .030 (.4 x .8) 3 Places 0.20 Dia. (0.5) 2 Coil Terminals
CONTACT LOAD RATINGS
LOAD CONDITION SPST-NO SPDT 7 AMPS @ 250 VAC 7 AMPS @ 30 VDC 210 WATTS (DC) 1750 VA (AC) 7 AMPERES 125 VDC 380 VAC 1/10 HP @ 120 VAC B300
Struthers-Dunn
Part Numbers 276AXXH-5D 276AXXH-6D 276AXXH-12D 276AXXH-24D 276XAXH-5D 276XAXH-6D 276XAXH-12D 276XAXH-24D COIL - Measured at 25C Nominal Nominal Nominal ResisContact Input power tance Configuration Voltage (mW) (Ohms) 200 5 VDC 125 SPST-NO 200 6 VDC 180 SPST-NO 200 12 VDC 720 SPST-NO 200 24 VDC 2880 SPST-NO 200 5 VDC 125 SPDT 200 6 VDC 180 SPDT 200 12 VDC 720 SPDT 200 24 VDC 2880 SPDT
10 AMPS @ 250 VAC 10 AMPS @ 30 VDC * MAX. SWITCHING POWER: 300 WATTS (DC) 2500 VA (AC) * MAX. SWITCHING CURRENT: 10 AMPERES * MAX. SWITCHING VOLTAGE: 125 VDC 380 VAC 1/6 HP @ 120 VAC MOTOR: B300 PILOT DUTY: RESISTIVE LOADS:
* Voltage current, and power ratings in the table above are independent maximums and no single value is to be exceeded.
PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION. NOTE: Coil polarity must be observed. Relay is polarized with a permanent magnet and will not be damaged with reverse polarity but will not operate with reverse polarity.
WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
PAGE 44
CLASS
90
30 AMP MINIATURE P.C. BOARD RELAY
CLASS 90 RELAY
SPST-N.O. or SPDT CLASS "B" OR "F" INSULATION EPOXY SEALED.
BREAKAWAY NIB OVER VENT HOLE (REMOVED AFTER CLEANING).
Class 90 printed circuit board relays provide an inexpensive means of switching loads up to 30 amps. Designed primarily for the appliance industry and HVAC markets, they are also well suited for load management, automotive and other applications.
Recognized Component mark for Canada and the United States.
C
US
UL Recognized File No. E13224
PC BOARD LAYOUT
(Bottom View )
Pending
ABA
.100 (2.54)
BA
.400 (10.1) .500 (12.7)
WIRING DIAGRAM
BOTTOM VIEW
.600 (15.2)
FIG. "A"
SPST-NO
FIG. "C"
SPST-NO
NOT USED ON CLASS "F" STYLES
.150 (3.8) .550 (13.9) .700 (17.8) .350 (8.9)
Drill "A" Holes .086 (2.19). Drill "B" Holes .046 (1.17).
FIG."B"
SPDT
FIG."D"
SPDT
OUTLINE DIMENSIONS
(Actual Size)
Dimensions are in Inchs and (Millimeters) VENT HOLE NIB 1.08 MAX. (27.4) .830 MAX. (21.08) .208 Max. (5.28) .031 x .062 (.8 x 1.6) .045 x .045 (1.1 x 1.1)
.693 (17.6)
.100 (2.54)
1.30. (33) Pin removed on Class "F" styles.
Stand0ff (qty.5)
.78 (19.8) .96 (24.3)
.150 (3.8)
.025 x .025 (.64 x .64)
PAGE 45
WEBSITE: www.magnecraft.com - EMAIL:info@magnecraft.com - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
30 AMP MINIATURE P.C. BOARD RELAY
SPECIFICATIONS CLASS 90
COIL Pull-in Voltage: Dropout Voltage: Coil Power: Duty: Insulation System: Coil Resistance: CONTACTS Contact Configuration: Contact Material: Contact Resistance: TIMING Operate Time: Release Time: DIELECTRIC STRENGTH Across open Contacts Contacts to Coil: Insulation Resistance: 75% of Nominal Voltage or less 10% of Nominal Voltage or more. 2.8 Watts Max. Continuous Class "B" (130C) or Class "F" (155C 10% measured at 25C SPST-N.O., SPDT Silver Cadmium Oxide. 50 Milliohms Max. Initial Value. 15 mS Max. @ Nominal Voltage. 10mS Max. @ Nominal Voltage. 1000 V rms 1500 V rms 500 Megohms under normal conditions 100 Megohms High Temp, High humidity. TEMPERATURE Operating: Storage: Relative Humidity: Atmospheric Pressure: VIBRATION RESISTANCE Functional: SHOCK RESISTANCE Functional: Mechanical: LIFE -55C to +105C -55C to +130C Up to 93% @ 40C. 650 to 800 mmHg.
CLASS
90
10 to 55 Hz @ Double Amplitude of 1 mm. 10 g's for 11 mS, no Contact Opening > 100uS, 100 g's
Electrical (Rated Load): Operations: See Table Below Mechanical (No Load): 10 million Operations . MISCELLANEOUS Operating position: Enclosure: Weight: Any 94V-0 Flammability rating, Epoxy sealed Immersion cleanable. 27 Grams approximately.
R
SILVER CADMIUM OXIDE CONTACT RATINGS Load Type Resistive Resistive Ind. & Res. SPST N.O. 30A @ 240VAC 20A @ 277 VAC 12A @ 277 VAC 1HP @ 125VAC 3/4 HP @ 125VAC 2HP @ 240/250VAC 470VA @ 125/240VAC 30FLA/96LRA, 125VAC 30FLA/80LRA, 240VAC 20FLA/60LRA, 277VAC 27FLA/82.8LRA,125VAC TV 3 @ 250VAC 6Amp @ 277VAC 20A @ 5-30VDC
FIGURE "C" & "D" MEETS UL 508 & UL 873 SPACING . SPDT N.C. OPERATIONS 100,000 2-10A @ 240VAC, (i&R) 15 AMP @ 240 (i) 100,000 6A @ 277VAC, I&R 6,000 1/4HP @ 125VAC 1/2HP @ 250VAC 275VA @ 125/240VAC 10FLA/33LRA, 125VAC 10FLA/33LRA,240VAC
Voltage
AC Motor
DC
Tungsten Ballast Resistive
SPDT N.O. OPERATIONS 20A @ 240VAC 100,000 20A @ 277 VAC 100,000 12A @ 277 VAC 6,000 30,000 1HP @ 125VAC 100,000 3/4HP @ 125VAC 1,000 2HP @ 240/250VAC 470VA @ 125/240VAC 100,000 30,000 30FLA/96LRA, 125VAC 30,000 30FLA/80LRA, 240VAC 20FLA/60LRA, 277VAC 100,000 27FLA/82.8LRA,125VAC 100,000 25,000 TV 3 @ 250VAC 6Amp @ 277VAC 6,000 20A @ 5-30VDC 100,000
30,000 30,000 30,000 100,000 100,000 6,000 100,000
TV 3 @ 250VAC 3 AMP@ 277VAC 10A @ 5-30VDC
COIL Measured @ 25C PART NUMBERS
NOMINAL NOMINAL INPUT RESISTANCE VOLTAGE (Ohms) NOMINAL POWER (mW)
CROSS REFERENCE POTTER & BRUMFIELD OMRON
SPST-NO , ( 30 AMP ) CLASS "B" INSULATION, FIG "A" WIRING W90S1D12-5 W90S1D12-12 W90S1D12-24 W90S1D12-110 5VDC 12VDC 24VDC 110VDC 27 155 660 13,450 930 930 870 900 T90S1D12-5 T90S1D12-12 T90S1D12-24 T90S1D12-110 G8P1114PB1USDC5 G8P1114PB1USDC12 G8P1114PB1USDC24 G8P1114PB1USDC110
SPDT, ( 20 AMP ) CLASS "B" INSULATION, FIG "B" WIRING W90S5D12-5 W90S5D12-12 W90S5D12-24 W90S5D12-110 5VDC 12VDC 24VDC 110VDC 27 155 660 13,450 930 930 870 900 T90S5D12-5 T90S5D12-12 T90S5D12-24 T90S5D12-110 G8P114PB1USDC5 G8P114PB1USDC12 G8P114PB1USDC24 G8P114PB1USDC110
SPST-NO, ( 30 AMP ) CLASS "F" INSULATION, FIG "C" WIRING W90S1D42-5 W90S1D42-12 W90S1D42-24 W90S1D42-110 5 VDC 12 VDC 24 VDC 110VDC 27 155 660 13,450 930 930 870 900 T90S1D42-5 T90S1D42-12 T90S1D42-24 T90S1D42-110 G8P1114PCFUSDC5 G8P1114PCFUSDC12 G8P1114PCFUSDC24 G8P1114PCFUSDC110
SPDT, ( 20 AMP ) CLASS "F" INSULATION, FIG "D" WIRING W90S5D42-5 W90S5D42-12 W90S5D42-24 W90S5D42-110 5 VDC 12 VDC 24 VDC 110VDC 27 155 660 13,450 930 930 870 900 T90S5D42-5 T90S5D42-12 T90S5D42-24 T90S5D42-110 G8P114PCFUSDC5 G8P114PCFUSDC12 G8P114PCFUSDC24 G8P114PCFUSDC110
PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION.
WEBSITE: www.magnecraft.com - EMAIL:info@magnecraft.com - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
PAGE 46
CLASS
91
30 AMP PC or FLANGE MOUNT MINIATURE RELAY
CLASS 91 RELAY
AC COIL VOLTAGES 30 AMP SWITCHING CLASS "F" INSULATION PC or FLANGE MOUNTED. * REMOVABLE TAPE SEAL OVER VENT HOLE (REMOVED AFTER PC BOARD DRILL PATTERN CLEANING).
BOTTOM VIEWS .250 Max. (6.35) A A .500 (12.7) A .250 Max. (6.35) .100 (2.54)
.300 (7.62)
B
B
.150 (3.81) HOLE "A" = .081 (005) Dia. HOLE "B" = .043 (003) Dia.
.550 (13.9) .700 (17.8)
OUTLINE DIMENSIONS (Actual Size)
Dimensions are in "inches" & (Millimeters)
*Tape over vent hole is only supplied on the P.C. terminal versions of this relay.
N.C. A1 N.O. A1
.032 x .62 (.81 x 1.57)
1.270 Max. (32.26)
A1 COM.
FIGURE "A" P.C. MOUNT
.045 x .046 (1.14 x 1.14) .025 x .025 (.63 x .63) 2 places
.130 .020 (3.30 .51)
1.080 Max. (27.43)
1.10 Max. (27.94)
WIRING DIAGRAM
BOTTOM VIEWS
N.C. A1 1.713 .010 (43.51 .25) N.O. A1 A1 COM. 1.980 Max. (50.29) 1.27 Max. (32.26)
FIGURE "B" FLANGE MOUNT
SPDT
SPST-NO
B1
B1
.071Rad. (1.80) For #6 screw ( 2 places) A1 = .250 x .032 (6.35 x .81) Quick Connect Terminal B1 = .187 x .020 (4.78 x .508) Quick Connect Terminal
PAGE 47
WEBSITE: www.magnecraft.com - EMAIL:info@magnecraft.com - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
30 AMP PC or FLANGE MOUNT MINIATURE RELAY
SPECIFICATIONS CLASS 91
COIL Pull-in Voltage AC: Dropout voltage: Max. coil voltage: Power consumption: Duty: Insulation System: Coil Resistance CONTACT Contact Configuration: Contact Material: Switching voltage: Contact Resistance: Minimum Load: TIMING Operate Time: Release Time: DIELECTRIC STRENGTH Between Open Contacts: Contacts to coil: Insulation Resistance 85% of Nominal Voltage or Less 10% of Nominal voltage or More 120% Max. 2.0VA max. AC Coils Continuous Class "F" (155C) 10% measured @ 25C TEMPERATURE Operating: Storage: VIBRATION RESISTANCE Functional: -55C to +85C -55C to +130C
CLASS
91
10 to 55Hz 1.5 mm max. No contact opening 100 uS >
SHOCK RESISTANCE Functional: SPST-N.O., SPDT Silver Cadmium Oxide 277 Vac, 30VDC max. 50 Milliohms @ 100mA, 6VDC Max. 1A, 5VDC, 12VAC Mechanical: LIFE Electrical (Rated Load) Mechanical (No Load): MISCELLANEOUS Operating Position: Enclosure:
10 g's for 11 mS, No contact Opening > 100 uS 100 g's
100,000 Operations 1 million Operations (AC) 10 million Operations (DC) Any Epoxy sealed immersion cleanable suitable for automatic circuit board processing. Max. exposure to temperature is 6 sec.@ 300C. 1/4" Q.C. Contacts, 3/16" Q.C. Coil 33 Grams, 1.2 oz approx.
20 mS max 20 mS max.
1500 V rms 2500V rms 1000 m min. @ 500 VDC
Terminals: Weight:
CONTACT RATINGS RATING SPST-NO 50/60Hz N.O. SPDT 50/60Hz N.O. 20A @ 240VAC 20A @ 28 VDC 1 HP @ 125VAC 2HP @ 240VAC TV-5, 120VAC 10A, 277VAC 50/20 @ 240AC N.C. 10A @ 240VAC 10A @ 28VDC 1/4HP @ 120VAC 1/2HP @ 240VAC TV-3, 120VAC 3A, 277VAC 20/7 @ 240AC
RESISTIVE 30A @ 240VAC 20A @ 28VDC LOAD 1 HP @120VAC hp 2HP @ 240VAC Tungsten TV-5, 120VAC 10A, 277VAC Ballast LRA/FLA 80/30 @ 240AC 98/22 @ 120AC
PART NUMBERS SPST-NO 30AMP P.C. MT. FIGURE "A" SPDT 20AMP P.C. MT. FIGURE "A" SPST-NO 30AMPFLANGE MT. FIGURE "B" SPDT 20AMP FLANGE MT. FIGURE "B"
Coil measured @ 25 C
NOMINAL NOMINAL NOMINAL RESIS- POWER INPUT TANCE (VA) VOLTAGE (Ohms) 2 VA 2 VA 2 VA
AC OPERATED COIL W91S1A22-24 W91S5A22-24 W91S1A32-24 W91S5A32-24 24 VAC W91S1A22-120 W91S5A22-120 W91S1A32-120 W91S5A32-120 120 VAC W91S1A22-240 W91S5A22-240 W91S1A32-240 W91S5A32-240 240 VAC
PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION.
WEBSITE: www.magnecraft.com - EMAIL:info@magnecraft.com - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
PAGE 48
CLASS
9A
! W NE
30 AMP PC or FLANGE MOUNT MINIATURE RELAY
CLASS 9A RELAY
Recognized Component mark for Canada and the United States.
30 AMP SWITCHING. C US UL Recognized CLASS "F" INSULATION. File No. E43641 PC or FLANGE MOUNTED. EPOXY SEALED WITH REMOVABLE TAPE SEAL OVER VENT HOLE (REMOVED AFTER CLEANING). PC BOARD DRILL PATTERN
BOTTOM VIEWS .140 Max. (3.56) A A .600 .500 (15.24) (12.7) A .250 Max. (6.35) .100 (2.54)
.300 (7.62)
B
B
.150 (3.81)
OUTLINE DIMENSIONS (Actual Size)
Dimensions are in "inches" & (Millimeters)
.550 (13.97) .700 (17.8)
HOLE "A" = .081 .005 Dia. (2.06 x .13) HOLE "B" = .043 .08 Dia. (1.09 x .08)
NO
A1
NC
A1 A1
.032 x .62 (.81 x 1.57)
1.270 Max. (32.26)
FIGURE "A" P.C. MOUNT
1.10 Max. (27.94)
.045 x .045 (1.14 x 1.14) .025 x .025 (.63 x .63) 2 places
.130 .020 (3.30 .51)
COM
1.080 Max. (27.43)
WIRING DIAGRAM
BOTTOM VIEWS
COM
1.713 .010 (43.51 .25)
NO
A1
NC
A1 A1 1.980 Max. (50.29) 1.27 Max. (32.26)
FIGURE "B" FLANGE MOUNT
SPDT
SPST-NO
B1
B1
B1
B1
.071Rad. (1.80) For #6 screw ( 2 places)
A1 = .250 X .032 (6.35 X .81) Quick Connect Terminal B1 = .187 x .020 (4.78 x .508) Quick Connect Terminal
PAGE 49
WEBSITE: www.magnecraft.com - EMAIL:info@magnecraft.com - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
30 AMP PC or FLANGE MOUNT MINIATURE RELAY
SPECIFICATIONS CLASS 9A
COIL Pull-in Voltage: Dropout voltage: Max. coil voltage: Power consumption: Duty: Insulation System: Coil Resistance CONTACT Contact Configuration: Contact Material: Switching voltage: Contact Resistance: Minimum Load: TIMING Operate Time: Release Time: DIELECTRIC STRENGTH Between Open Contacts: Contacts to coil: Insulation Resistance 75% of Nominal Voltage or Less 10% of Nominal voltage or More 120% Max. 2.8 Watts max. Continuous Class "F" (155C) 10% Measured @ 25C SPST-N.O., SPDT Silver Cadmium Oxide 277 VAC, 28VDC max. 75 Milliohms @ 1 min, rated current (switched) 1A, 5VDC, 12VAC DC:15 mS typ. including bounce DC:15mS typ. including bounce 1500 V rms 2500V rms 1000 m min. @ 500 VDC, 25C 50% RH TEMPERATURE Operating: Storage: VIBRATION RESISTANCE Functional: SHOCK RESISTANCE Functional: Mechanical: LIFE Electrical (Rated Load) Mechanical (No Load): MISCELLANEOUS Operating Position: Enclosure: -55C to +85C -55C to +130C
CLASS
9A
10 to 55Hz 1.65 mm max. No contact opening 100 uS > 10 g's for 11 mS, No contact Opening > 100 S 100 g's 100,000 Operations 10 million Operations Typical Any Epoxy sealed immersion cleanable suitable for automatic circuit board processing. Max. exposure soldering temperature is 4 sec.@ 500F. 94V-O Flammability rating. 1/4" Q.C. & safety wells accept insulated Female Q.C. terminals. 33 Grams, 1.2 oz approx.
Enclosure: Terminals: Weight:
CONTACT RATINGS
Meets UL 508, UL 873 and UL 1950 - 1/8" thru air - 1/4" over surface (See Foot notes) AC Measured @ 50/60Hz RATING GENERAL PURPOSE RESISTIVE RESISTIVE HEATER MOTOR (HP) MOTOR FLA/LRA TUNGSTEN BALLAST PILOT DUTY LOAD VOLTAGE 240 VAC 240 VAC 28 VDC 240 VAC 125 VAC 240 VAC 120 VAC 240 VAC 240 VAC 277 VAC 240 VAC SPST N.O. 30A 20A 20A 25A 1 HP 2 HP 22/98A 30/80A TV-5 10A 470 VA N.C. *15A 15A 10A 1/4 HP 1/2 HP 12/30A 3A 275 VA N.O. 20A 20A 20A 1 HP 2 HP 30/80A TV-5 10A 470 VA SPDT N.C. 10A 15A 10A 1/4 HP 1/2 HP 12/30A 3A 275 VA 100,000 100,000 100,000 100,000 1,000 1,000 30,000 30,000 25,000 6,000 6,000 OPERATIONS
* 15 Amp general purpose rating on SPST-NC contact valid only under UL 508 column B spacings and UL 873 columns B, C & D spacings. Derate to 10 Amps when used under UL 873 columns E & F spacings and UL 1950. 15 Amp resistive rating on SPST-NC contacts and SPDT contacts (Normally closed side only) valid only under UL 873 columns E & F spacings. Derate to 10 Amps when used under UL 508 Column B spacings, under UL 873 columns B, C & D spacings and UL 1950. The resistance heater rating is not a discreet UL heater rating but is a valid UL rating that is derived from the UL general purpose category in the above table of contact ratings. FLA = Full load Amps, LRA = Locked rotor Amps.
PART NUMBERS SPST-NO 30AMP P.C. MT. FIGURE "A" SPDT 30AMP P.C. MT. FIGURE "A" SPDT SPST-NO 30AMP 30AMPFLANGE MT. FLANGE MT. FIGURE "B" FIGURE "B" W9AS1D52-5 W9ASID52-12 W9ASID52-24 W9ASID52-48 W9ASID52-110 W9AS5D52-5 W9AS5D52-12 W9AS5D52-24 W9AS5D52-48 W9AS5D52-110
Coil measured @ 25 C
NOMINAL NOMINAL NOMINAL RESIS- POWER INPUT TANCE (Watts) VOLTAGE (Ohms) 5 12 24 48 110 25 144 576 2,304 12,100 1W 1W 1W 1W 1W
DC OPERATED COIL W9AS1D22-5 W9AS5D22-5 W9ASID22-12 W9AS5D22-12 W9ASID22-24 W9AS5D22-24 W9ASID22-48 W9AS5D22-48 W9ASID22-110 W9AS5D22-110
PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION.
WEBSITE: www.magnecraft.com - EMAIL:info@magnecraft.com - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
PAGE 50
CLASS
92
! W NE
30 AMP PC or FLANGE MOUNT 2 POLE RELAY
CLASS 92 RELAY
30 AMP SWITCHING. CLASS "F" INSULATION. PC or FLANGE MOUNTED. EPOXY SEALED WITH * REMOVABLE TAPE SEAL OVER VENT HOLE (REMOVED AFTER CLEANING).
Recognized Component mark for Canada and the United States.
C
US
UL Recognized File No. E43641
PC BOARD DRILL PATTERN
.162 (4.12) BOTTOM VIEWS .630 .005 (16.00) .203 TYP (5.16)
.309 .005 (7.85 .13)
.585 .005 (14.8 .13)
HOLE "B"
OUTLINE DIMENSIONS
Dimensions are in "inches" & (Millimeters) 1.33 Max. (33.78)
HOLE "A"
.185 TYP (4.70)
1.618 TYP (41.10 .51)
1.00 .010 (25.40) HOLE "A" = .072 x .050 typ. (1.83) HOLE "B" = .052 x .050 typ. (1.32)
.309 .005 (7.85 .13) 2.06 Max. (52.32)
.586 .005 (14.8 .13)
FIGURE "A" P.C. MOUNT
.047 TYP. (1.19) .250 TYP (6.35) .156 (3.96)
1.618 TYP (41.10 .51)
.032 TYP (0.81) .630 .005 (16.00) 1.00 .010 (25.40) 1.10 Max. (27.94) 1.04 Max. (26.42)
Note: An alternate P.C. Board layout Utilizes .076 .003 diameter holes on the layout above. Use of retangular holes is recommended for improved solderability. *Tape over vent hole is only supplied on the P.C. terminal versions of this relay.
WIRING DIAGRAM
TOP VIEW 6 8 7 1 2 4 3 0
.309 .005 (7.85 .13) 2.06 Max. (52.32) 2.35 .005 (59.7 .13)
2.70 Max. (68.58)
.585 .005 (14.8 .13)
FIGURE "B" FLANGE MOUNT
.250 TYP (6.35)
DPDT
6 8
2 4
1.618 TYP (41.10 .51)
1
0
DPST-NO
1.485 Max. (37.72) Only necessary terminals are present on single throw styles.
1.36 Max. (34.54)
.090 Rad (2.29) For #8 screws
PAGE 51
WEBSITE: www.magnecraft.com - EMAIL:info@magnecraft.com - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
30 AMP PC or FLANGE MOUNT 2 POLE RELAY
SPECIFICATIONS CLASS 92
COIL Pull-in Voltage: AC: 80% of Nominal Voltage or Less DC: 75% of Nominal Voltage or Less 10% of Nominal voltage or More Dropout voltage: 120% Max. Max. coil voltage: Max. Operating Frequency: 14 Operations per minute AC Coil: 4.0VA, DC Coil: 1.7W Nominal Power: Continuous Duty: Class "F" (155C) Insulation System: 10% Measured @ 25C Coil Resistance TEMPERATURE Operating:
CLASS
92
AC:-40C to +65C, DC:-40C to +85C
VIBRATION RESISTANCE 0.065 (1.65 mm) double amplitude-10 thru 55 Hz Functional: SHOCK RESISTANCE Functional: Mechanical: LIFE Electrical (Rated Load) Mechanical (No Load): MISCELLANEOUS Operating Position: Enclosure: Flammability: Weight:
10 g's for 11 mS, 1/2 sign wave pulse with no contact opening > 100s 100 g for 11 ms 1/2 sine wave pulse
CONTACT Contact Configuration: Contact Material: Contact Load Ratings: Contact Resistance: Minimum Load:
DPDT Standard Silver Cadmium Oxide SEE CONTACT LOAD RATINGS CHART 100 Milliohms @ Initial rated current (switched) N.O. 500 mA @ 12 VAC/VDC N.C. 100mA @ 6 VAC/VDC
100,000 Operations 5 million Operations Typical
Any Epoxy sealed immersion cleanable tape sealed plastic cover. 94V-O Flammability rating. 86 Grams, 3 oz approx.
TIMING Operate Time: Release Time: DIELECTRIC STRENGTH Between Open Contacts: Contacts to coil: Insulation Resistance
DC:15 mS typ. 25ms w/ bounce DC:10mS typ. 25 ms w/ bounce
1500 V rms 4000V rms 103 meg min. @ 500 VDC, 25C 50% RH
CONTACT RATINGS
Meets UL 873 and UL 508 spacing - (8mm) thru air, (9.5 mm) over surface. AC Measured @ 50/60Hz RATING Resistive Load DPST-N.O. & DPDT N.O. CONTACTS DPDT N.C. CONTACTS 3A @ 277VAC 3A @ 28VDC
30A @ 120/277 VAC 20A @ 28 VDC 1 HP @ 120VAC Hp 2.5 HP @ 240VAC Tungsten TV-10, 120VAC LRA/FLA* 96/22 @ 240VAC, AC Coil 110/25.3 @ 240VAC, DC Coil Pilot Duty 3A @ 240 VAC
Note: Vent tape must be removed to achieve listed ratings * FLA = Full load Amps, LRA = Locked rotor Amps. .
PART NUMBERS DPST-NO 30AMP P.C. MT. FIGURE "A" DPDT 30AMP P.C. MT. FIGURE "A" DPST-NO 30AMPFLANGE MT. FIGURE "B" DPDT 30AMP FLANGE MT. FIGURE "B"
CROSS REFERENCE TO OMRON The relay listed below are crossed to Magnecraft DPST-NO, 30 Amp, Flange mount, Figure "B" only. NOMINAL NOMINAL NOMINAL See Note below for Variations RESISPOWER between relays. INPUT VOLTAGE TANCE (Ohms) OMRON PART NUMBERS Coil measured @ 25 C 86 350 1,390 7,255 4 VA 4 VA 4 VA 1.7 W 1.7 W 1.7 W 1.7 W G7L-2A-TUBJ-CB-AC24 G7L-2A-TUBJ-CB-AC120 G7L-2A-TUBJ-CB-AC240 G7L-2A-TUBJ-CB-DC12 G7L-2A-TUBJ-CB-DC24 G7L-2A-TUBJ-CB-DC110 G7L REPLACES G5D22423T
AC OPERATED COIL W92S7A22-24 W92S11A22-24 24 VAC W92S7A22-120 W92S11A22-120 120 VAC W92S7A22-240 W92S11A22-240 240 VAC DC OPERATED COIL W92S7D12-12 W92S11D12-12 W92S7D22-12 W92S11D22-12 W92S7D12-24 W92S11D12-24 W92S7D22-24 W92S11D22-24 W92S7D12-48 W92S11D12-48 W92S7D12-110 W92S11D12-110 W92S7D22-110 W92S11D22-110 12 VDC 24 VDC 48 VDC 110 VDC
PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION. Note: The Class W92 Meets Fit and Function when replacing the Omron G7L relay. The case size ( width & lenght ) and mounting centers on flange are Dimensionally identical except the class 92 is lower in height. The W92 has a higher contact switching rating then the G7L and requires less coil power for operation. The 1/4" (.250) Q.C. terminals on top of the case of the Class 92 are not located in the same positions as the G7L, but wire hookup will work with existing wiring using Q.C. connectors..
WEBSITE: www.magnecraft.com - EMAIL:info@magnecraft.com - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
PAGE 52
CLASS
7
SUBMINIATURE PC MOUNTABLE, EPOXY SEALED
CLASS 7
2 AMP SWITCHING IN THE WORLDS SMALLEST PACKAGE. SPDT, DPDT.
ACTUAL SIZE
The Class 7 Subminiature high reliability industrial grade relay has excellent R.F. switching characteristics.
Recognized Component mark for Canada and the United States.
C
US
AVAILABLE WITH SPDT OR DPDT BIFURCATED GOLD CLAD SILVER-PALLADIUM CROSS BAR CONTACTS- RATED FOR LOW LEVEL TO 2.0 AMP SWITCHING. REQUIRES ONLY .155 SQUARE INCH OF CIRCUIT BOARD SPACE. TOTAL VOLUME OF LESS THAN A CUBIC CENTIMETER. CONFORMS TO FCC PART 68.302. 1500 V PEAK SURGE RESISTANCE. CONFORMS TO FCC PART 68.304. 1000 V DIELECTRIC WITHSTANDING VOLTAGE..
UL Recognized File No. E52197
TOP VIEW SHOWN AT ACTUAL SIZE ON A 0.1 GRID
DIP
CLASS 7
CLASS CLASS 7 7 SIZE COMPARISON OF STANDARD DIP RELAY TO CLASS 7 RELAYS
PC BOARD PATTERN
Drill Plan (TOP VIEW)
.100 (2.54) .100 (2.54) .300 (7.62)
The Class 7 relays can be densely packed together without magnetic interaction from adjacent relays.
.100 (2.54)
.300 (7.62)
.039 Dia. (1.0)
0.1 Grid Pattern
OUTLINE DIMENSIONS
Dimensions are in "INCHES" and ( MILLIMETERS ) .410 Max. PIERCE THRU (10.4) VENT HOLE .410 Max. (10.4)
WIRING DIAGRAM
BOTTOM VIEW
v
^
SPDT
.428 Max. (10.9)
v
^
v
^
.100 Typ (2.54) .125 (3.18) .024 x .012 (0.6 x 0.3 ) DPDT
PAGE 53
WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
SUBMINIATURE PC MOUNTABLE, EPOXY SEALED
COIL Coil Voltages Pull-in Voltage: Dropout: Max. allowed coil voltage: Nominal Power: Max. coil dissipation Coil Resistance range: CONTACTS Contact Configuration: Contact Rating: Contact Material: Contact Resistance:
CLASS
7
SPECIFICATIONS CLASS 7
80% of Nominal Voltage or less 10 % of Nominal Voltage or More 120% of nominal voltage, duty cycle: 100%. 327 Milliwatts max., min sensitivity: 200 milliwatts. 0.75 watts. 10% SPDT, DPDT SPDT: 50uA @ 50mV, 2A , 24VDC, 2A, 120VAC, DPDT: 50uA @ 50mV, 2A, 24VDC, 0.6A,100VAC, Gold Clad Silver Palladium. Initial 50 m 100 Milliohms max @ 6VDC 10 Milliamps. TEMPERATURE Operating: -35C to +70C
VIBRATION RESISTANCE Functional: 15 g's, 10 to 2000 Hz, No contact opening > 10 uS Max. contact chatter Destructive: 50 g'S. SHOCK RESISTANCE Functional 50g's 6mS half sine Mechanical: Destructive: 150 g's. LIFE Mechanical: Electrical: 100 Million Operations 100,000 Operations- 2 Amp 24VDC, 1.0 AMP 120VAC (Rated Load). Terminals are solder Coated and Epoxy free to provide excellent solderability. Max. exposure to soldering temperature is 5 seconds @ 250C. After cleaning process, pierce a small hole in cover for venting. Any UL, 94V-O Plastic, Epoxy Sealed. 2.7 Grams . (.095 oz.)
TIMING Operate Time: Release Time:
4.0 mS Max. @ Nominal Voltage. Typ. 5.0 mS Max. @ Nominal Voltage. Typ
MISCELLANEOUS Terminal Finish:
DIELECTRIC STRENGTH All Mutually Insulated Points: 500 VAC for 1 Minute, 1 Milliamp max. leakage, or 600VAC for 1 Second, 1 Milliamp leakage. Meets FCC 68.302 ( 1500V Surge ) Surge Test: and 68.304 ( 1000V Dielectric ). 500 VDC Exceeds 1000 Megohms. Insulation Resistance: 4 MILLISECONDS 3 2 1 RELEASE TIME 0 0.7 0.5 0.3 0.6 0.8 0.4 COIL APPLIED POWER (WATTS) R.F. PERFORMANCE Frequency Insertion Loss (dB) Common to N.O. or N.C. Contacts 0.05 0.10 0.30 0.50 0.60 0.65 0.75 VSWR Common to N.O. or N.C. Contacts 1.03:1 1.04:1 1.05:1 1.06:1 1.07:1 1.08:1 1.10:1 Isolation (dB) N.O. or N.C. Contacts to Coil 65 50 42 35 31 29 28 0.9 OPERATE/RELEASE TIME OPERATE TIME
Mounting Position: Enclosure: Weight:
After cleaning process, pierce 0.40 (1mm) hole in cover for venting. COIL TEMPERATURE RISE E2 Rt E2 R20
80 70 TEMP. RISE C 60 50 40 30 20 10 0
(MHz)
0.1 0.2 0.3 0.4 0.5 0.6 0 . 7 0.8 COIL POWER CONSUMPTION
COIL VOLTAGE COIL RESIST. VALUE AFTER TEMP. WAS RAISED COIL VOLTAGE COIL RESIST. VALUE AT 20C
10 50 100 200 300 400 500
E2 = Rt E2 = R20
COIL - Measured at 25C Part Numbers Contact Configuration Nominal Input Voltage 5 VDC 12 VDC 24 VDC 5 VDC 12 VDC 24 VDC Nominal Resistance (Ohms) 75 440 1550 75 440 1550 Nominal Power (mW) 330 330 370 330 330 370
CROSS REFERENCE
COMMUNICATIONS INSTRUMENTS INC / MIDTEX (CII / MIDTEX)
W7PCX-1 W7PCX-3 W7PCX-4 W7PCX-5 W7PCX-7 W7PCX-8
SPDT SPDT SPDT DPDT DPDT DPDT
MMS105 MMS112 MMS124 MMS205 MMS212 MMS224
PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION.
WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
PAGE 54
CLASS
60
MINIATURE P.C. BOARD RELAY MOUNTABLE ON 0.100 GRID
CLASS 60
BIFURCATED CROSS BAR CONTACTS LOW LEVEL SWITCHING TO 2 AMPS SPDT,DPDT CONTACTS
W60HE1S
W60HE2S
Recognized Component mark for Canada and the United States.
C
US
UL Recognized File No. E52197
The Class 60 Miniature high reliability industrial grade relay has excellent RF switching characteristics.
OUTLINE DIMENSIONS
DIMENSIONS SHOWN IN "INCHES" AND (MILLIMETERS)
1.10 Max (27.9)
ACTUAL SIZE
.570Max (14.4)
FIGURE "A"
TOP VIEW SHOWN AT ACTUAL SIZE ON A 0.1 GRID W60HE1S
.175 Max (4.45)
.010 (0.25) .025 SQ. PINS (0.64) .092 (2.34)
.040 DIA (1.01) TYP.
W60HE2S
.600 Max (15.2)
1.10Max (27.9)
.040 DIA (1.01) TYP.
CIRCUIT DIAGRAMS
.570Max (14.4)
FIGURE "B"
BOTTOM VIEW
SPDT
.010 (0.25) .175 Max (4.45) .025 SQ. PINS (0.64) .105Max (2.67)
DPDT
.895 Max (22.7)
PAGE 55
WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
MINIATURE P.C. BOARD RELAY MOUNTABLE ON 0.100 GRID
SPECIFICATIONS CLASS 60
COIL Pull-in Voltage: Dropout Voltage: Max. allowed voltage: Nominal power: Max. coil dissipation: Coil Resistance CONTACTS Contact Material: Contact Resistance: Contact Rating: 80% of Nominal Voltage or less 10% of nominal voltage or more 120% of nominal voltage, duty cycle 100% 327mW max. min. sensitivity: 200 mW 0.75 Watt 10% Measured @ 25C Gold Clad Silver Palladium. Initial 50 Milliohms @ 6VDC, 10mA 100 Milliohms max., After life: 200 m Low Level: 50uA- 50mV, SPDT: 2A-24VDC, 2A-120VAC, DPDT: 2A-24VDC, 0.6A-100VAC, 4.0 mS Max. @ Nominal Voltage. 10.0 mS Max. @ Nominal Voltage. 2.5 mS operate, 5.0 mS release 500 VAC for 1 Minute, 1 Milliamp max. leakage, or 600VAC for 1 Second, 1 Milliamp leakage. Meets FCC 68.302 ( 1500V Surge ) and 68.304 ( 1000V Dielectric ). 500 VDC Exceeds 1000 Megohms. -35C to +70C 15g's, 10 to 2000Hz, (No contact opening greater than 10S) 50g's, 6mS Max. Contact Chatter Destructive 50g's. 100,000 Operations Rated Load. 100 Million Operations Terminals are solder Coated to provide excellent solderability. Max. exposure to soldering temperature is 5 seconds @ 250C. Any Plastic. SPDT-5.5 g's, DPDT- 9 g's approx.
CLASS
60
TIMING Operate Time: Release Time: Contact bounce: DIELECTRIC STRENGTH All Mutually Insulated Points: Surge Test: Insulation Resistance: TEMPERATURE Operating: VIBRATION RESISTANCE Functional: SHOCK RESISTANCE Functional: Mechanical: LIFE Electrical (Rated Load): Mechanical (No Load): MISCELLANEOUS Terminal Finish:
Operating Position: Enclosure: Weight:
COIL Measured @ 25C
PART NUMBERS FIGURE "A" W60HE1S-5DC W60HE1S-12DC W60HE1S-24DC W60HE1S-48DC FIGURE "B" W60HE2S-5DC W60HE2S-12DC W60HE2S-24DC W60HE2S-48DC
Contact Nominal Configu- Input ration Voltage SPDT SPDT SPDT SPDT DPDT DPDT DPDT DPDT 5VDC 12VDC 24VDC 48VDC 5VDC 12VDC 24VDC 48VDC
CROSS REFERENCE Resis- Pull-in TO Power tance POTTER & BRUMFIELD (Ohms) (mW) 75 440 1550 5250 75 440 1550 5250 200 200 200 200 200 200 200 200 R50E2Y1-5V R50E2Y1-12V R50E2Y1-24V R50E2Y1-48V R50E2Y2-5V R50E2Y2-12V R50E2Y2-24V R50E2Y2-48V
PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION.
WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
PAGE 56
CLASS
178
MINIATURE 12 AMP EPOXY SEALED PC BOARD RELAY
CLASS 178
5 AMP AND 12 AMP SPDT CONTACTS. EPOXY SEALED. CLASS "B" INSULATION SYSTEM. WITHSTANDS THE VAPOR AND SPRAY CLEANING OF MOST FLUXING SYSTEMS. TERMINALS ARE SOLDER COATED TO PROVIDE EXCELLENT SOLDERABILITY.
Recognized Component mark for Canada and the United States.
C
US
UL Recognized File No. E164066
ACTUAL SIZE
UL CONTACT LOAD RATINGS
5 AMP RELAY STYLE OPERATIONS LOAD 100,000 5A @125V AC 100,000 5A @250V HP 25,000 1/4 @ 120V 25,000 N.C. 1/4 @ 120V 25,000 120V TV-3 TV-5 125VA @ 120V 25,000 VA DC 100,000 5A @ 30V DC MOTOR 5A,120VAC,pf=0.5 100,000 LOAD 12 AMP RELAY STYLE OPERATIONS LOAD 6,000 12A @ 120V 100,000 10A @ 125V 100,000 10A @ 250V 10A, 1/4 @ 120V 100,000 N.O. 10A, 1/4 @ 250V 25,000 10A, 1/4 @ 120V 90,000 N.C. 25,000 125V 6,000 12A @ 28V 100,000 N.C* 10A @ 30V PC BOARD LAYOUT ( BOTTOM VIEW )
.100 (2.54) .090 (2.29)
.472 (12.0 .236 (6.0)
.079 (2.0)
.480 (12.2) .044 Dia. (1.1) (5 Holes)
*N.0. CONTACT 25,000 @ 30 VDC
OUTLINE DIMENSIONS
Dimensions are in "INCH" and ( MILLIMETERS )
.650 Max (16.5)
WIRING DIAGRAM
( BOTTOM VIEW ) 2 v .620Max. (15.7) 1 3
PIERCE THRU VENT HOLE
^
5 4
.012 (.30)
SPDT
.012 (.30) .039 (.99) .890 Max (22.5) .140 Typical (3.6)
.039 (.99)
.016 (.40)
PAGE 57
WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957, Document 100
CLASS
MINIATURE 12 AMP EPOXY SEALED PC BOARD RELAY
SPECIFICATIONS CLASS 178
COIL Pull-in Voltage: Dropout Voltage: Maximum Voltage: Insulation system: Coil Resistance: Duty: CONTACTS Contact Configuration: Contact Material: Contact Resistance: Minimum Load: 75% of Nominal Voltage or less 10% of nominal Voltage or more. 110% of nominal voltage Class "B" (130C per UL std. 1446) 10% @ 25C Continuous
178
SPDT Silver Cadmium Oxide 100 Milliohms @ 5VDC & 1 Amp Max. 100mA @ 12VDC
TIMING Operate Time: Release Time: Bounce Time (typical): DIELECTRIC STRENGTH Contacts to Coil: Across open Contacts: Insulation Resistance: TEMPERATURE Operating: VIBRATION RESISTANCE Functional: SHOCK RESISTANCE Functional: LIFE EXPECTANCY Electrical (Rated Load): Mechanical (No Load): MISCELLANEOUS Terminal Finish:
20 mS Max. @ Nominal Voltage. 10mS Max. @ Nominal Voltage. Operate: 1ms, typ., Release: 4 ms, typ.
1500 VAC for 1 Minute or 1800 VAC 1 Sec 750 VAC for 1 Minute or 800 VAC 1 Sec . 100 Megohms M in. @ 500 VDC
-40C to +70C
10 to 55Hz Dual Amplitude -1.5 mm
10g's for 11mS (No Contact Opening >100 uS
100,000 Operations 10 Million Operations
Operating Position: Enclosure:
Weight:
P.C. Terminals are solder Coated and Epoxy free to provide excellent solderability. Max. exposure to soldering temperature is 6 seconds @ 300C. Any Plastic, Epoxy sealed, suitable for Automatic Circuit Board Processing. After cleaning process, pierce a small hole in cover for venting. 0.42 oz. (12) grams approximately.
PART NUMBERS W178RE1-5DC W178RE1-12DC W178RE1-24DC W178URE1-5DC W178URE1-12DC W178URE1-24DC
CONTACT RATING
COIL Measured @ 25C NOMINAL NOMINAL NOMINAL INPUT POWER RESISTANCE VOLTAGE (mW) (OHMS) 5VDC 12VDC 24VDC 5VDC 12VDC 24VDC 70 400 1600 70 400 1600 400 400 400 400 400 400
CROSS REFERENCE TO POTTER & BRUMFIELD T70L5D131-5VDC T70L5D131-12VDC T70L5D131-24VDC T70L5D164-5VDC T70L5D164-12VDC T70L5D164-24VDC IDEC RCN1V-5G-DC5V RCN1V-5G-DC12V RCN1V-5G-DC24V OMRON G5L-114P-PS-DC5 G5L-114P-PS-DC12 G5L-114P-PS-DC24
5 AMPS 5 AMPS 5 AMPS 12 AMPS 12 AMPS 12 AMPS
RCN1V-10G-DC5V G5LE-114P-PS-DC5 RCN1V-10G-DC12V G5LE-114P-PS-DC12 RCN1V-10G-DC24V G5LE-114P-PS-DC24
PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION.
WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957, Document 100
PAGE 58
CLASS
49
MINIATURE ENCLOSED PC BOARD RELAY - 3 TO 10 AMP
CLASS 49 RELAY
LOW LEVEL TO 10 AMPS. PRINTED CIRCUIT OR BRACKET MOUNTING. 49RE1C2UL Recognized File No. E52197
Only 1.1 cubic inches. Variety of mounting configurations. Printed circuit terminals. Tapped mounting holes (49R1C4). TV 5 rating available. Standard pilot duty 240 VAC. Magnetic motor controller rating 1/3 Hp at 120VAC.
49R1C4-
OUTLINE DIMENSIONS (Actual Size)
ALL DIMENSIONS ARE IN INCHES AND MILLIMETERS Recommended P.C. board holes .067 dia.(1.7)
49RE1C1STYLE RE1C2
.759 Max. (19.3) 1.25 Max. (31.7)
ALL TERMINALS ARE .056 X .025 (1.42 X 0.64)
STYLE RE1C1
.759 Max. (19.3) 1.25 Max. (31.7)
1.14 Max. (29.1)
1.14 Max. (29.1)
.186 typ. (4.72)
.210 (5.3)
.310 (7.8) .379 (9.63
.593 (15.0)
.453 (11.5)
.097 (2.5)
.210 (5.3)
.310 (7.8)
.313 (7.9)
.843 (21.4)
.150 (3.8)
.546 (13.8 1.015 (25.7)
.594 (15.0)
.915 (23.2) .687 (17.4)
STYLE R1C4
1.225 (31.1) .562 (14.2)
.131 (.33) .328 (8.3)
WIRING DIAGRAMS
(BOTTOM VIEW)
1.34 Max. (34.1)
STYLE RE1C1 R1C4
1.14 Max. (29.1)
STYLE RE1C2
.210 (5.3)
.310 (7.8) 4-40 Tapped holes (2 Req.)
.313 (7.9)
.843 (21.4)
.150 (3.8)
SPDT SPDT
.759Max. (19.3)
PAGE 59
WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
MINIATURE ENCLOSED PC BOARD RELAY - 3 TO 10 AMP
CLASS
49
SPECIFICATIONS CLASS 49
COIL Pull-in Voltage: Dropout voltage: Max. coil voltage Duty: Resistance: CONTACTS Contact Configuration: Contact Material: Contact Resistance: Contact Rating: VG, VW adj. (DC) = 75% , VF, VG adj. (AC) = 80%,of nominal coil voltage or less. 10% of actual pull-in or more 120% Max. Continuous 10% SPDT Silver Cad Oxide (5, 10 Amp), 3 Amp (Silver, Gold Plated). 100 Milliohms Max. initial Value @ 6 Vdc, 1 Amp 5 and 10 Amp @ 120/240 AC, 3 Amp @ 120 VAC, 28 VDC resistive. Motor load: 1/3 Hp @120VAC, 10 Amp only. TV 3 SPST-NO, SPST-NC, SPDT TV 5 SPST-NO, (10 Amp only). SPST-NO, SPST-NC, SPDT B300 10 mS typical (25 mS max.) 7mS typical (10 mS max.) DIELECTRIC STRENGTH Contacts to coil: Across open contacts: Coil to frame: Insulation Resistance: TEMPERATURE Operating: Storage: VIBRATION RESISTANCE Functional: SHOCK RESISTANCE Functional: Mechanical: LIFE Electrical (Rated Load): Mechanical No Load): MISCELLANEOUS Soldering temperature: Operating position: Enclosure: Weight: 1,500 V rms 500 V rms 1,500 V rms 1000 m min. @ 500 VDC -55C to +85C -55C to +130C 10 to 55 Hz @ 1.65mm Displacement 10 g's 100 g's 100,000 Operations. . 50,000, 000 Operations. 270C (518F) max. for 5 seconds max.. Any. Dust cover. 42 Grams, 1.5 oz approximately.
Pilot Duty: TIMING Operate: Release Time:
PART NUMBERS PRINTED CIRCUIT BOARD MOUNTING SPDT, 3 AMP STYLE RE1C1 W49RE1C1VG-3DC-SIL W49RE1C1VG-5DC-SIL W49RE1C1VG-12DC-SIL W49RE1C2VF-6DC-SIL W49RE1C2VF-12DC-SIL W49RE1C2VF-24DC-SIL SPDT, 5 AMP STYLE RE1C1 AND RE1C2 W49RE1C1VG-5DC-SCO W49RE1C1VG-12DC-SCO W49RE1C1VG-24DC-SCO W49RE1C2VF-6DC-SCO W49RE1C2VF-12DC-SCO W49RE1C2VF-24DC-SCO SPDT, 10 AMP STYLE RE1C1 W49RE1C1VW-5DC-SCO W49RE1C1VW-12DC-SCO W49RE1C1VW-24DC-SCO SOLDER TERMINALS, BRACKET MOUNTING SPDT, 5 AMP- STYLE R1C4 W49R1C4VG-5DC-SCO W49R1C4VG-12DC-SCO SPDT,10 AMP W49R1C4VW-5DC-SCO W49R1C4VW-24DC-SCO
COIL Measured @ 25C Nominal Input Voltage 3 VDC 5/6 VDC 12 VDC 6 VDC 12 VDC 24 VDC 5/6 VDC 12 VDC 24 VDC 6 VDC 12 VDC 24 VDC 5/6 VDC 12 VDC 24 VDC Nominal Resistance (Ohms) 90 235 1350 410 1640 6560 235 1350 5400 410 1640 6560 100 600 2400 Pull-in Power (mW) 60 60 60 56 56 56 60 60 60 56 56 56 135 135 135
CROSS REFERENCE GUARDIAN CORNELL DUBILIER 653-3K 653-6K 653-12K
1345-1C-5DC 1345-1C-12DC 1345-1C-24DC
603-6B 603-12B 603-24B
613-6B 613-12B 613-24B
5/6 VDC 12 VDC 5/6 VDC 24 VDC
235 1350 100 2400
60 60 135 135
PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION.
WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
PAGE 60
CLASS
76
MINIATURE EPOXY SEALED PC BOARD POWER RELAY
CLASS 76
5, 10 and 16 AMP. CONTACT RATINGS EPOXY SEALED, IMMERSION CLEANABLE MEETS 8mm SPACING 5KV DIELECTRIC
UL Recognized File No. E13224
CONTACT LOAD RATINGS
FIGURE "A" DPDT (5 AMP) 5AMP @ 250VAC RES. 5AMP @ 30VDC 1/4HP @ 250VAC FIGURE "C" SPDT (10AMP) 10AMP @ 250VAC RES. 10AMP @ 30VDC 1/3HP @ 250VAC FIGURE "B" SPDT (16AMP) 16AMP @ 240VAC RES. 16AMP @ 24VDC 1/2HP @ 250VAC
OUTLINE DIMENSIONS (Actual Size)
All Dimensions are in inches and (millimeters)
1.142 Max. (29.0)
.512 Max. (13.0)
PIERCE THRU VENT HOLE
.811Max. (20.6)
.138
(3.5)Max.
WIRING DIAGRAM
(BOTTOM VIEW)
FIGURE "A"
FIGURE "B"
FIGURE "C"
FOOT PRINT FOR 70-475 SOCKET
FOOT PRINT FOR 70-475 SOCKET
FOOT PRINT FOR 70-478 SOCKET
DRILLING PLAN
(BOTTOM VIEW)
.400 (10.1)
.059 (1.5)
.400 (10.1) .300 (7.62)
.059 (1.5)
.059 (1.5) .795 (20.19) .300 (7.62) .300 (7.62) .28 (7.11)
.795 (20.19)
FIGURE "A"
.039 Dia. (1.0)
.795 (20.19)
FIGURE "B"
.039 Dia. (1.0)
FIGURE "C"
.039 Dia. (1.0)
SEE SECTION 10 FOR MATING SOCKETS PAGE 61 WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
CLASS
MINIATURE EPOXY SEALED PC BOARD POWER RELAY
76
SPECIFICATIONS CLASS 76
COIL Pull-in Voltage: Dropout Voltage: Nominal Power: Coil Resistance CONTACTS Contact Material: Contact Resistance: Max.cycle rate: Minimum Switching Load: TIMING Operate Time: Release Time: Bounce Time: (Mean Value) DIELECTRIC STRENGTH Contacts to Coil: Across Open Contacts: Creepage & Clearance Insulation Resistance: DC-75% of Nominal Voltage or less 5% of Nominal Voltage or More 600 mW(1 pole) 800 mw (2 pole )Approx.. 10% Measured @ 20C TEMPERATURE Operating: Humidity: VIBRATION RESISTANCE Functional: SHOCK RESISTANCE Functional: Mechanical: LIFE Electrical (Rated Load): Mechanical (No Load): MISCELLANEOUS Operating position: Enclosure: -30C to +70C 45 - 85% RH
10 to 55 Hz Dual Amplitude 1.5mm
Silver Cadmium Oxide 100 Milliohms Max. 30 Operations per Minute @ rated Load. 10 VDC @ 10 mA
10 g's Min 100 g Min.
15 mS Max. @ Nominal Voltage. 10 mS Max. @ Nominal Voltage. 1.2 mS Approx.
100,000 Operations min. 10,000,000 Operations min.
5000 V rms, for 1 Minute 1000 V rms, for 1 Minute 8 Millimeters Min. Coil & Contacts 500VDC Exceeds 100 Megohms
Weight:
Any Epoxy sealed for protection during automatic wave soldering & cleaning process. After cleaning process, pierce a small hole in cover for venting. 13 Grams approx.
PART NUMBERS W76EURCPCX-14 W76EURCPCX-15 W76EURCPCX-16 W76EURCPCX-17 W76EURCPCX-18 W76EURCPCX-61 W76EURCPCX-62 W76EURCPCX-63 W76EURCPCX-64 W76EURCPCX-146 W76EURCPCX-147 W76EURCPCX-148 W76EURCPCX-149 W76EURCPCX-150
FIG. "C" "C" "C" "C" "C" "A" "A" "A" "A" "B" "B" "B" "B" "B"
COIL Measured @ 20C NOMINAL Nominal CONTACT CONTACT Resistance CONFIGUINPUT RATING (Ohms) RATION VOLTAGE 5 VDC 6 VDC 12 VDC 24 VDC 48 VDC 5 VDC 6 VDC 12 VDC 24 VDC 5 VDC 6 VDC 12 VDC 24 VDC 48 VDC 47 68 275 1,100 4,170 47 68 275 1,100 47 68 275 1,100 4,170 SPDT SPDT SPDT SPDT SPDT DPDT DPDT DPDT DPDT SPDT SPDT SPDT SPDT SPDT 10 AMP 10 AMP 10 AMP 10 AMP 10 AMP 5 AMP 5 AMP 5 AMP 5 AMP 16 AMP 16 AMP 16 AMP 16 AMP 16 AMP
CROSS REFERENCE POTTER & BRUMFIELD RKS-5DG-05 RKS-5DG-06 RKS-5DG-12 RKS-5DG-24 RKS-5DG-48 RKS-11DG-05 RKS-11DG-06 RKS-11DG-12 RKS-11DG-24 RKS-5DW-05 RKS-5DW-06 RKS-5DW-12 RKS-5DW-24 RKS-5DW-48 OMRON G2R-14-DC5 G2R-14-DC6 G2R-14-DC12 G2R-14-DC24 G2R-14-DC48 G2R-24-DC5 G2R-24-DC6 G2R-24-DC12 G2R-24-DC24 G2R-1-E-DC5 G2R-1-E-DC6 G2R-1-E-DC12 G2R-1-E-DC24 G2R-1-E-DC48 AROMAT JW1FEN-DC5V JW1FEN-DC6V JW1FEN-DC12V JW1FEN-DC24V JW1FEN-DC48V JW2EN-DC5V JW2EN-DC6V JW2EN-DC12V JW2EN-DC24V
PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION.
WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
PAGE 62
CLASS
1330 & 1335
! W NE
ENCLOSED MINIATURE 2 POLE RELAY
SPACE SAVING DPDT, P.C. BOARD RELAY AC OR DC OPERATED COIL. RATED: 5 AMPS RESISTIVE, 3 AMPS INDUCTIVE SPECIFICATIONS CLASS 1330 & 1335
COIL Pull-in Voltage: Dropout: Max. Voltage: Coil Resistance: Duty: CONTACTS Contact Configurations: Contact Material: Contact Resistance: 75% of Nominal Voltage or less for AC or DC Coils DC -10% min.or more. 110% 10% @ 25C Continuous DPDT Silver Cadmium Oxide, .93 Dia. (2.36). 100 Milliohms Max. UL RATED - 5 Amperers @ 120 VAC resistive NOT UL RATED - 30 VDC resistive, 3 Amperes Inductive, 1/8 Hp @ 120 VAC. 20mS Max. AC, 15 mS Max. DC @ Nominal Voltage, 25C. 20mS Max. AC, 15 mS Max. DC @ Nominal Voltage, 25C. 1500 V rms 500 V rms 1500 V rms 1500 Megohms Min. -45C to + 70C @ Rated Operation. AC operated Device in excess of 50 million operations DC operated devices, in excess of 100 million operations. 100,000 Operations Min. (at rated Resistive load). Any. Molded parts are diallyl phthalate for higher arc resistance. Clear heat resistant Polycarbonate Dust Cover. Approximately 3/4 oz.
Recognized Component mark for Canadian and the United States.
C
UL Recognized File No. E52197
US
PENDING
MANUFACTURED UNDER QUALITY SYSTEM
Contact Rating: TIMING Operate Time: Release Time: DIELECTRIC STRENGTH Coil to Frame: Across Open Contacts: Contact to Frame: Insulation Resistance: TEMPERATURE Ambient Temperature: LIFE EXPECTANCY Mechanical Electrical (rated Load): MISCELLANEOUS Operating Position: Insulating Material: Enclosure: Weight:
ISO 9002 & QS 9000
1.075 Max. (27.3)
.200 Max.
1
.728 Max. (18.5)
2 5 8 3 6 9 11
P.C. BOARD LAYOUT
.189 (4.8) .728 Ref (18.5) .350 (8.9) .123 (3.1)
CIRCUIT DIAGRAM
4 7 10
.905 Max. (23)
.157 (4)
.020 Max. (.5) Ref.
.052 Typ. (1.31)
.905 Ref (23)
.354 .197(5) (9) .551 (14) .197(5)
.067 Dia. (1.7) 8 PL
.231 Ref (5.9)
PART NUMBERS
Nominal Input Voltage
Coil Measured at 25C CROSS REFERENCE Nominal Nominal TO Resistance Power GUARDIAN (Ohms) 245 5400 125 500 1.2 VA 1.2 VA 1.2 W 1.2 W 1330P-2C-24A 1330P-2C-120A 1335P-2C-12D 1335P-2C-24D
AC OPERATED COILS W1330P-2C-24A 24 VAC W1330P-2C-120A 120 VAC DC OPERATED COILS W1335P-2C-12D 12 VDC W1335P-2C-24D 24 VDC
PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION.
PAGE 63
WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
SECTION
3
3
REED RELAYS FOR PRINTED CIRCUIT BOARD APPLICATIONS 4 VA TO 100 VA. COAXIAL RELAYS FOR R.F. SWITCHING. Page 64
Magnecraft
Struthers-Dunn
PRINTED CIRCUIT BOARD REED RELAYS
RELAY SERIES "SIP" "DIP" NEW!
DPDT DIP SPDT
UP
101
131 MERCURY
UP
DPDT SOCKET AVAILABLE SEE SECTION 10 SPDT - EPOXY MOLDED CONSTRUCTION. DPDT ENCAPSULATED CONSTRUCTION. STANDARD 0.1 GRID SPACING. AVAILABLE WITH SUPPRESSION DIODE ACROSS COIL. CLASS 107 PROVIDES 4 HOOK- UP PINS TO COIL.. ELECTROSTATIC SHIELD OPTIONAL. CONTACT CONFIGURATION: MAXIMUM CONTACT RATING: SPST-NO, SPST-NC MAX. SWITCHING 0.5 AMPS or 200 VDC @ 10 VA SPST-NO, or NC, SPDT, DPDT MAX. SWITCHING 0.5 AMPS or 100 VDC @ 4VA -10VA
FEATURES
EPOXY MOLDED CONSTRUCTION. STANDARD 0.1 GRID SPACING. AVAILABLE WITH OR WITHOUT SUPPRESSION DIODE ACROSS COIL.. .
ENCAPSULATED CONSTRUCTION OR EPOXY MOLDED WITH SIDE TERMINALS STANDARD 0.1 GRID OR OPTIONAL 0.15 SPACING. NON LATCHING SINGLE COIL OR SINGLE & DUAL COIL MAGNETIC LATCHING. ELECTROSTATIC SHIELD OPTIONAL.
ENCAPSULATED CONSTRUCTION. STANDARD 0.1 GRID OR OPTIONAL 0.15 SPACING. POSITION SENSITIVE VERTICAL MOUNTING. EXCELLENT FOR LOW LEVEL SWITCHING. ELECTROSTATIC SHIELD OPTIONAL.
1 to 3PST-NO, MAX. SWITCHING 0.5 AMPS or 200 VDC @ 10 VA
SPST-NO, DPST-N0 MAX. SWITCHING 2.0 AMPS or 500 VDC @ 50 VA
MAX.CARRY LOAD 1.5 AMPS MAX.CARRY LOAD 1.5 AMPS MAX.CARRY LOAD 2.0 AMPS MAX.CARRY LOAD 3.0 AMPS
CONTACT MATERIAL: CONTACT RESISTANCE:
RHODIUM 100 MILLIOHMS (INITIAL)
RHODIUM 100 MILLIOHMS (INITIAL)
RHODIUM 100 MILLIOHMS (INITIAL)
MERCURY (Hg) 50 MILLIOHMS (INITIAL)
INSULATION CHARACTERISTICS
DIELECTRIC STRENGTH: 1500 V rms 1000 V rms 500 VDC 1000 V rms
COIL DATA
DC - VOLTAGE RANGE: 5, 12, 24 VDC 5, 12, 24 VDC 5, 12, 24 VDC 5, 12, 24 VDC
NOMINAL POWER:
270 mW Max.
650 mW Max.
380 mW Max.
625 mW Max.
GENERAL DATA
AMBIENT TEMPERATURE OPERATIONAL: TIMING VALUES MAX. OPERATE: MAX. RELEASE: LIFE MECHANICAL: ELECTRICAL: - 40 C to + 85 C - 40 C to + 85 C - 40 C to + 85 C - 37 C to + 85 C
1 MILLISECONDS 1 MILLISECONDS
1 MILLISECONDS 1 MILLISECONDS
1 MILLISECONDS 1 MILLISECONDS
2 MILLISECONDS 2 MILLISECONDS
100 MILLION OPERATIONS 50 MILLION OPERATIONS H W L
100 MILLION OPERATIONS 50 MILLION OPERATIONS H W L .275 X .300 X .750 .338 X .393 X .750 (DPDT) ANY
100 MILLION OPERATIONS 50 MILLION OPERATIONS H W L
100 MILLION OPERATIONS 40 MILLION OPERATIONS H W L
DIMENSIONS: MOUNTING POSITION:
APPLICATION DATA:
.290 X .280 X .750 ANY
.355 X .400 to .900 X 1.15 ANY
.355 X PG.39 X 1.15 VERTICAL 15
PAGE NUMBER: PAGE 65
PAGE 68, 69 PAGE 70
PAGE 71 thru 75
MINIATURE REED SPECIFICATIONS:
PAGE 77
PAGE 76 PAGE 78
WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
Magnecraft
Struthers-Dunn
MINIATURE REED RELAYS
104 134 MERCURY 193 MR-Y MRR & RR
UP
DUST COVER STANDARD. DUST COVER STANDARD. ENCAPSULATED CONSTRUC- ENCAPSULATED CONTION OPTIONAL STRUCTION OPTIONAL STANDARD 0.1 GRID OR OPTIONAL 0.15 GRID SPACING AVAILABLE. STANDARD 0.1 GRID OR OPTIONAL 0.15 SPACING AVAILABLE. POSITION SENSITIVE. VERTICAL MOUNTED.
DUST COVER STANDARD. ENCAPSULATED CONSTRUCTION OPTIONAL STANDARD 0.1 GRID OR OPTIONAL 0.15 GRID SPACING. UP TO 4PDT OR 6PST CONTACT ARRANGEMENTS.
EPOXY MOLDED. STANDARD 0.1 GRID OR OPTIONAL 0.15 GRID SPACING AVAILABLE. MAGNETIC SHIELDING.
EPOXY MOLDED AXIAL LEAD REED RELAY EXTERNAL MAGNETIC SHIELDING FIXED TO BODY. SOLID LEADS
END TERMINALS. TTL COMPATIBLE.
SPDT, DPDT MAX SWITCHING 0.25 AMPS or 100VDC @ 4 VA MAX.CARRY LOAD 0.5 AMP
SPDT, DPDT MAX SWITCHING 1.0 AMPS or 500VDC @ 50 VA
1 to 4PDT, 1 to 6PST MAX SWITCHING 0.5 AMPS or 200VDC @ 10 VA
1 & 2PST-NO or NC SPDT, DPDT MAX SWITCHING 0.5 AMPS or 200VDC @ 10 VA
1 to 12PST-NO 0r NC MAX SWITCHING 0.5 AMP or 200VDC @ 10 VA
MAX.CARRY LOAD 2.0 AMP. MAX.CARRY LOAD 2.0 AMP MAX.CARRY LOAD 1.5 AMP MAX.CARRY LOAD 1.5 AMPS MERCURY 100 MILLIOHMS (INITIAL) RHODIUM 200 MILLIOHMS (INITIAL)
RHODIUM 200 MILLIOHMS (INITIAL)
RHODIUM 200 MILLIOHMS (INITIAL)
RHODIUM 200 MILLIOHMS (INITIAL)
500 V rms
1000 V rms
500 V rms
500 V rms
500 V rms
5, 12, 24 VDC
5, 12, 24 VDC
5, 12, 24 VDC
5, 12, 24 VDC
6 to 48 VDC
626 mW Max.
620 mW Max.
1030 mW Max.
450 mW Max.
400 mW Max.
-40C to + 85 C
-37 C to + 85 C
-40 C to + 85 C
-40C to + 85 C
-40 C to + 85 C
1 MILLISECONDS 1 MILLISECONDS
2 MILLISECONDS 3 MILLISECONDS
1 MILLISECONDS 1.5 MILLISECONDS
1 MILLISECONDS 1 MILLISECONDS
5 MILLISECONDS 5 MILLISECONDS
100 MILLION OPERATIONS 50 MILLION OPERATIONS H W L
100 MILLION OPERATIONS 40 MILLION OPERATIONS H W L
100 MILLION OPERATIONS 100 MILLION OPERATIONS 200 MILLION OPERATIONS 50 MILLION OPERATIONS 50 MILLION OPERATIONS 10 MILLION OPERATIONS H W L .355 X .4 to .9 X 1.15 ANY H W L DIAMETER .655 X 1.875 ANY
.355 X .5 to .7 X 1.15 ANY
355 X .5 to .5 X 1.15 VERTICAL 15
.312 X 0.4 X .950 ANY
PAGE 79
PAGE 80
PAGE 81, 82
PAGE 83, 84
PAGE 85, 86 PAGE 66
WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
Magnecraft
Struthers-Dunn
P.C. BOARD REED RELAYS & COAXIAL
RELAY SERIES RRN 102 120 COAXIAL
FEATURES
OPEN END CONSTRUCTION WITH METAL COVER MAGNETIC SHIELDING 0.2 GRID SPACING SINGLE PIECE GLASS FILLED BOBBIN AND TERMINALSUPPORT VARIOUS CONTACT ARRANGEMENTS.
OPEN END CONSTRUCTION DRY REED SWITCHING UP TO 3.0 AMPS @ 250 VDC. METAL COVER/SHIELD STANDARD 0.2 GRID SPACING.
150 WATT SWITCHING UP TO 470 MHz. RG58C/U CABLE, 12" LONG STANDARD. 50 OHM IMPEDANCE 1 FORM C (DPDT) R.F. SWITCHING CONTACTS.
CONTACT DATA
CONTACT CONFIGURATION: MAXIMUM CONTACT RATING: See Catalog Page MAX SWITCHING 0.5 or 1.0 AMP or 250VDC @ 10 or 15 VA SPST-NO MAX SWITCHING 1.0 or 3.0 AMPS or 250VDC @ 15 or 100 VA MAX.CARRY LOAD 2 or 3.5 AMPS
SPDT
150 Watts up to 470 MHz
CONTACT MATERIAL: CONTACT RESISTANCE:
RHODIUM 200 MILLIOHMS (INITIAL)
RHODIUM 200 MILLIOHMS (INITIAL)
SILVER ALLOY GOLD FLASHED 50 MILLIOHMS (INITIAL)
INSULATION CHARACTERISTICS
DIELECTRIC STRENGTH: 1500 V rms 1500 V rms 1,500 V rms
COIL DATA
DC - VOLTAGE RANGE: 6 to 48 VDC 12, 24 VDC 12 VDC
NOMINAL POWER:
700 mW Max.
800 mW Max
1.44 Watts
GENERAL DATA
AMBIENT TEMPERATURE OPERATIONAL: TIMING VALUES MAX. OPERATE: MAX. RELEASE: LIFE MECHANICAL: ELECTRICAL: -40 C to + 85 C -40 C to + 85 C - 55 C to + 65 C 15 MILLISECONDS 7 MILLISECONDS
6 MILLISECONDS 6 MILLISECONDS
5 MILLISECONDS 6 MILLISECONDS
200 MILLION OPERATIONS 10 MILLION OPERATIONS H W L .641 X 0.74 X 2.50 ANY
100 MILLION OPERATIONS 20 MILLION OPERATIONS H W L
100,000 OPERATIONS 5 MILLION OPERATIONS H W L .1.62 X.703 X 1.73 ANY
DIMENSIONS MOUNTING POSITION PAGE NUMBER PAGE 67
0.65 X 0.76 X 2.67 ANY
PAGE 87, 88
PAGE 89
PAGE 90
WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
APPLICATION DATA
HOW REED RELAYS WORK
REED RELAYS
MERCURY-WETTED CONTACT RELAYS. ( CONTINUED) The term reed relay covers dry reed relays and mercury-wetted contact relays, all of which use hermetically sealed reed switches. In both types, the reeds (thin, flat blades) serve multiple functions as conductor, contacts, springs, and magnetic armatures. DRY REED RELAYS Dry reed relays have become an important factor in the relay field. They have the advantage of being hermetically sealed and resistant to atmospheric contamination. They have fast operate and release times and when operated within their rated contact loads, have very long life. A typical dry reed switch capsule is shown in Figure 1. Mercury wetted contacts are fast in operation and have relatively good load carrying capacity and long life. The mercury films are reestablished at each contact closure and contact erosion is eliminated.. The mercury films are stretchable, there is no contact bounce and because it is a mercury contact, the contact resistance is very low and ideal for low level switching applications. The disadvantages of this type of reed relay are the freezing point of mercury (-38C), poor resistance to shock and vibration and the need to mount the relay in a near vertical position. These relays are used for a variety of switching applications such as found in computers, business machines, machine tool control systems, and laboratory instruments. CONTACT COMBINATIONS. The switches used in dry reed relays provide SPST-NO, SPST-NC, SPDT contact combinations. The SPST-NO corresponds with the basic switch capsule design (Fig.1). The SPST-NC results from a combination of the SPST-NO switch and a permanent magnet strong enough to pull the contacts closed but able to open when coil voltage is applied to the relay coil. In typical true SPDT designs, the armature is mechanically tensioned against the normally closed contact, and is moved to the normally open contact upon application of a magnetic field. The SPDT contact combination can also be achieved by joining a SPST-NO switch with an appropriately adjusted SPST-NC switch, and jumping one side of both switches together to form the movable contact system. Latching contacts, defined as contacts which remain in the position to which they were driven, and staying in that position when coil power is removed from the relay coil. Latching switches are manufactured by using a SPST-NO contact, and biasing it with a permanent magnetic that is strong enough to hold the contacts closed, but not strong enough to hold the contact closed when coil power is applied to the coil. The switching process is than reversed by simply reversing the relay coil polarity to close the switch. MAGNETIC FIELDS Reed relays in general can be characterized as susceptible to the influences of external magnetic fields. It is important to keep reed relays at a proper distance from each other because of the possibility of magnetic-interaction between them. Proper magnetic shielding must be used to contain stray magnetic fields. When installing reed relays into equipment, one should be aware of the devices within that equipment which can produce magnetic fields. The relays being installed into that equipment should be positioned as far away as possible from any stray magnetic fields and should be shielded to prevent false operations. ELECTRICAL CHARACTERISTICS SENSITIVITY: The input power required to operate dry reed relays is determined by the sensitivity of the particular reed switch used, by the number of switches operated by the coil, by the permanent magnet biasing (if used), and the efficiency of the coil and the effectiveness of its coupling to the blades. Minimum input required to effect closure ranges from the very low milliwatt level for a single sensitive capsule to several watts for multipole relays. OPERATE TIME: The coil time constant, overdrive on the coil, and the characteristics of the reed switch determine operate time. With the maximum overdrive voltage applied to the coil, reed relays will operate in approximately the 200 microsecond range. When driven at rated coil voltage, usually the relays will operate at about one millisecond. RELEASE TIME: With the coil unsuppressed, dry reed switch contacts release in a fraction of a millisecond. SPST-NO contacts will open in as little as 50 microseconds. Magnetically biased SPST-NC and SPDT switches reclose from 100 microseconds to 1 millisecond respectively.
Supporting Terminal
Figure 1. Construction of Switch Capsule of Typical Dry Reed switch (SPST-NO) In the basic SPST-NO design, two opposing blades are sealed into a narrow glass capsule and overlapped at their free ends. The contact area is plated typically with rhodium to produce a low contact resistance when contacts are drawn together. The capsule is made of glass and filled with a dry inert gas and then sealed. The capsule is surrounded by an electromagnetic coil. When the coil is energized, the normally open contacts are brought together; when the coil voltage is removed, the blades separate by their own spring tension. Some reeds contain permanent magnets for magnetic biasing to achieve normally closed contacts (SPST-NC) or SPDT contact combinations. The current rating, which is dependent upon the size of the blade and the type and amount of plating, may range from low level to 1 amp. Effective contact protection is essential when switching loads other then dry resistive loads. MERCURY-WETTED CONTACT RELAYS. Mercury wetted contacts consist of a glass-encapsulated reed with its base immersed in a pool of mercury and the other end capable of moving between one or two stationary contacts. The mercury flows up the reed by capillary action and wets the contact surfaces of the moving end of the reed as well as the contact surfaces of the stationary contacts. A mercury to mercury contact is maintained in the closed position. The capsule is surrounded by an electromagnetic coil and operates in the same manner as a dry reed. Supporting Leadwire
UP
OPERATING POSITION
Figure 2. Miniature Mercury-wetted contact switch (SPDT)
WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
656321 4 321 6565432109876543210987654654321 4321 321 6565432109876543210987654654321 45432109876543210987654654321 321 321 6565432109876543210987654654321 4321 321 6565432109876543210987654654321 4321 321 6565432109876543210987654654321 4321 321
Normally Open Contacts Glass Capsule Glass Capsule Mercury pool
Supporting Terminal
654321 54321 654321 654321 54321 654321 654321 654321 54321 54321 54321 54321 54321 54321 54321 54321 54321 54321 54321 54321 54321 54321 54321 54321 54321 54321 54321 54321 65432 65432 543211 654321 543211 654321 654321 654321
Movable contact blade
PAGE 68
REED RELAYS
APPLICATION DATA
NOISE Noise is defined as a voltage appearing between terminals of a switch for a few milliseconds following closure of the contacts. It occurs because the reeds (blades) are moving in a magnetic field and because voltages are produced within them by magnetostrictive effects. From an application standpoint, noise is important if the signal switched by the reed is to be used within a few milliseconds immediately following closure of the contacts. When noise is critical in an application, a peak-to-peak limit must be established by measurement techniques, including filters which must be specified for that particular switching application. ENVIRONMENTAL CHARACTERISTICS Reed relays are used in essentially the same environments as other types of relays. Factors influencing their ability to function would be temperature extremes beyond specified limits VIBRATION The reed switch structure, with so few elements free to move, has a better defined response to vibration than other relay types. With vibration inputs reasonably separated from the resonant frequency, the reed relay will withstand relatively high inputs, 20 g's or more. At resonance of the reeds, the typical device can fail at very low input levels. Typical resonance frequency is 2000 hz. SHOCK
ELECTRICAL CHARACTERISTICS (Continued) RELEASE TIME (Continued) If the relay coil is suppressed, release times are increased. Diode suppression can delay release times for several milliseconds, depending on coil characteristics, coil voltage, and reed release characteristics. CONTACT BOUNCE Dry reed contacts bounce on closure as with any other hard contact relay. The duration of bounce on a Dry reed switch is typically very short, and is in part dependent on drive level. In some of the faster devices, the sum of the operate time and bounce is relatively constant. As drive is increased, the operate time decreases with bounce time increasing. The normally closed contacts of a SPDT switch bounce more then the normally open contacts. Magnetically biased SPST-NC contacts exhibit essentially the same bounce characteristics as SPST-NO switches. CONTACT RESISTANCE The reeds (blades) in a dry reed switch are made of magnetic material which has a high volume resistivity, terminal-to-terminal resistance is somewhat higher than in some other types of relays. Typical specification limits for initial resistance of a SPST-NO reed relay is 0.200 ohms max (200 milliohms). INSULATION RESISTANCE A dry reed switch made in a properly controlled internal atmosphere will have an insulation resistance of 1012 to 1013 ohms or greater. When it is assembled into a relay, parallel insulation paths reduce this to typical values of 109 ohms. Depending on the particular manner of relay construction, exposure to high humidity or contaminating environments can appreciably lower final insulation resistance. CAPACITANCE. Reed capsules typically have low terminal-to-terminal capacitance. However, in the typicall relay structure where the switch is surrounded by a coil, capacitance from each reed to the coil act to increase capacitance many times. If the increased capacitance is objectionable, it can be reduced by placing a grounded electrostatic shield between the switch and coil. DIELECTRIC WITHSTAND VOLTAGE
Dry reed relays will withstand relatively high levels of shock. SPST-NO contacts are usually rated to pass 30 to 50 g's, 11 milliseconds, half sign wave shock, without false operation of contacts. Switches exposed to a magnetic field that keep the contacts in a closed position, such as in the biased latching form, demonstrate somewhat lower resistance to shock. Normally closed contacts of mechanically biased SPDT switches may also fail at lower shock levels. TEMPERATURE Differential expansion or contraction of reed switches and materials used in relay assemblies can lead to fracture of the switches. Reed relays are capable of withstanding temperature cycling or temperature shock over a range of at least -50C to + 100C. These limits should be applied to the application to prevent switch failure. CONTACT PROTECTION
With the exception of the High-Voltage dry reed switches ( capsules that are pressurized or evacuated), the dielectric strength limitation of relays is determined by the ampere turn sensitivity of the switches used. A typical limit is 200 VAC. The dielectric withstand voltage between switch and coil terminals is usually 500 VAC. THERMAL EMF
Tungsten lamp, inductive and capacitive discharge load are extremely detrimental to reed switches and reduce life considerably. Illustrated below are typical suppression circuits which are necessary for maximum contact life. FIGURE 3 Input R Input R
Since thermally generated voltages result from thermal gradients within the relay assembly, relays built to minimize this effect often use sensitive switches to reduce required coil power, and thermally conductive materials to reduce temperature gradients. Latching relays, which may be operated by a short duration pulse, are often used if the operational rate is not changed for longer periods of time because coil power is not required to keep the relay in the on or off position after the initial turn on or turn off pulse.
Initial turn-on current is generally 10 times higher than the rated operating current of the lamp. A current limiting resistor in series with the load, or a bleeder resistor across the contacts will suppress the inrush current. Thesesame circuits can be used with capacitive loads, as shown in Figure 3. FIGURE 4 Input Input
DC inductive loads call for either a diode or a thyristor to be placed across the load. These circuits are necessary to protect the contacts when inductive loads are to be switched in a circuit, as shown in Figure 4.
PAGE 69
WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
SINGLE IN-LINE PACKAGE REED RELAY
CLASS 117 "SIP"
0.5 AMP SWITCHING SPST-N.O. OR N.C. CONTACTS
SIP
SPECIFICATIONS CLASS 117SIP
Package Material: Contact Material: Ambient Temperature: Dielectric Strength: Epoxy, molded Rhodium - 40C to + 85C 150 V rms Across open contacts 500 V rms all other points Insulation Resistance: 1000 Megohms Min. Capacitance: 1.0 pF typical coil to contacts Shock Resistance: 50 G's Vibration Resistance: 20 G's to 200 Hz 1 Millisecond Max. Operate Time: 1 Millisecond Max. Release Time: 50 Million operations , 5-10V @ 10 mA Life 100 Million operations no load
OUTLINE DIMENSIONS
Dimensions shown are in "INCHES" & (Millimeters)
.290 Max. (7.36)
.750 Max. (19.5) .290 Max. (7.36).260 Max (6.60) .075 Max. (1.90) .020 Typ. (.51) Pin No. 1 Indicator
.110 (2.79)
.200Typ. (5.08) .600 (15.2)
.030 Max. (.762) .140 Max. (3.55)
.010 Typ. (.25)
CONSULT FACTORY FOR COMPLETE PART NUMBER WITH REQUIRED OPTIONS COIL Measured @ 25C CIRCUIT DIAGRAM TOP VIEW SPST - N.O. W117SIP-1 W117SIP-3 3 1 SPST - N.C. 5 7 W117SIP-5 5 12 24 4.0 9.6 19.2 0.5 1.0 2.0 500 1870 3200 50 77 180 3621A0500 3621A1200 3621A2400 JWS-117-1 JWS-117-3 JWS-117-5 PART NUMBERS NOMINAL INPUT VOLTAGE MAXIMUM CONTACT RATING CROSS REFERENCE TO HAMLIN POTTER & BRUMFIELD
NOMINAL NOMINAL MAXIMUM MINIMUM RESISSWITCHING CONTINUOUS POWER PULL-IN DROPOUT TANCE CARRY CURRENT LOAD (mW) (OHMS)
W117SIP-22 W117SIP-23 1 3+ 5 7 W117SIP-24
5 12 24
4.0 9.6 19.2
0.5 1.0 2.0
500 1200 2200
50 120 270 10VA 0.5 AMP 200VDC 1.5 AMPS
-
JWD-171-12 JWD-171-14 JWD-171-15
SPST - N.O. WITH CLAMPING DIODE W117SIP-6 W117SIP-8 5 12 4.0 9.6 19.2 0.5 1.0 2.0 500 1870 3200 50 77 180
3621A0510 3621A1210 3621A2410
JWS-117-6 JWS-117-8 JWS-117-10
24 W117SIP-10 7 3+ 1 5SPST - N.C. WITH CLAMPING DIODE W117SIP-18 W117SIP-25 1 3+ 57 W117SIP-26 5 12 24
4.0 9.6 19.2
0.5 1.0 2.0
500 1200 2200
50 120 220
-
JWD-171-17 JWD-171-19 JWD-171-30
NOTE: MAGNECRAFT FOOT PRINT IS IDENTICAL TO COMPETITOR PART NUMBERS SHOWN. COIL RESISTANCE MAY DIFFER SLIGHTLY FOR THE NOMINAL VOLTAGES SHOWN. PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION.
WEBSITE: www.magnecraft.com - EMAIL:info@magnecraft.com - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
PAGE 63
DIP
CLASS 107 DUAL IN-LINE PACKAGE REED RELAY
107 DIP RELAY
EPOXY MOLDED PROVIDES 4 HOOK-UP PINS TO COIL.
SPECIFICATIONS CLASS 107DIP
Package Material: Contact Material: Ambient Temperature: Dielectric Strength: Insulation Resistance: Capacitance: Operate Time: Release Time: Shock Resistance: Vibration Resistance: Life Operating Position: Weight: Epoxy, molded Rhodium - 40C to + 85C 150 V rms Across open contacts 500 V rms all other points 1000 Megohms Min. 2.0 pF typical coil to contacts 1 Milliseconds Max @ Nominal. 1 Milliseconds Max @ Nominal. 50 G's 20 G's to 200 Hz 50 Million operations at 5-10V @ 10mA 100 Million operations no load Any 1 gram approx.
14
.300 (7.62)
1
.100 typ. (2.54) .750 Max. (19.05)
.275 (6.98)
.020 (0.51) .020 typ. (0.51) .150 Typ. (3.81)
.010 (.254)
.400 (10.1) .600 (15.2)
CIRCUIT DIAGRAM TOP VIEW SPST - N.O. 14 13 9 8
COIL Measured @ 25C RELAY PART NOMINAL MAXIMUM MINIMUM INPUT NUMBERS PULL-IN DROPOUT VOLTAGE
MAX. CONTACT RATING
NOMINAL NOMINAL MAXIMUM MAXIMUM RESISPOWER SWITCHING CONTINUOUS TANCE (mW) LOAD (OHMS) CARRY CURRENT
CROSS REFERENCE TO POTTER & BRUMFIELD
W107DIP-1 W107DIP-3 W107DIP-4 1 2 6 7 8 W107DIP-5 W107DIP-7 SPST - N.O. WITH CLAMPING DIODE 14 13 9
5 12 24
3.8 9.0 18.0
0.5 1.0 2.0
500 1200 2200
50 120 260 10VA 0.5 AMP 100 VDC 1.5 AMPS
JWD-107-1 JWD-107-3 -
5 12 24
3.8 9.0 18.0
0.5 1.0 2.0
500 1200 2200
50 120 260
JWD-107-5 JWD-107-7 -
+
12 6 7
W107DIP-8
PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION. All DIP configurations are available with Magnetic Shielding (internal) and /or Low level applications on special order. Contact factory for special part numbers.
SEE SECTION 10 FOR MATING SOCKET PAGE 71 WEBSITE: www.magnecraft.com - EMAIL:info@magnecraft.com - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
SPECIFICATIONS CLASS 172 & 172 DIPS
SPECIFICATIONS 171DIP & 172 (SPDT)
Package Material: Contact Material: Ambient Temperature: Dielectric Strength: Insulation Resistance: Capacitance: Shock Resistance: Vibration Resistance: Operate Time: Release Time: Life Epoxy, molded Rhodium or Mercury (as selected) - 40C to + 85C 150 V rms Across open contacts 500 V rms all other points 1000 Megohms Min. 1.0 pF typical coil to contacts 50 G's 20 G's to 200 Hz 1 Millisecond max. 1 Millisecond max. 50 Million operations, 5-10V @ 10mA 100 Million operations Low Level
DIP
171 & 172 (SPDT)
OUTLINE DIMENSIONS
Dimensions shown are in "INCHES" & (Millimeters) 14
.300 (7.62)
1
.100 typ. (2.54) .750 Max. (19.05)
.275 (6.98)
.020 (0.51) .020 typ. (0.51) .150 Typ. (3.81)
.010 (.254)
.400 (10.1) .600 (15.2)
SPECIFICATIONS 172DIP (DPDT)
Package Material Contact Material: Coil Resistance: Contact Resistance: Ambient Temperature: Dielectric Strength:: Coil to contact: Insulation Resistance: Operate Time Release Time: Life: Dimensions shown are in "INCHES" & (Millimeters) Plastic Rhodium 10% @ 20C 150 M max. - 40C to + 85C 150 VDC min. 500 VDC min. 1000 Megohms Min. 0.7 Millisecond max. (including bounce) 1 Millisecond max. 50 million operations, 50V/50mA: 80 million operations, 10v/10mA: PACKAGE STYLE FOR W172 DIPS DPDT
PIN 1 LOCATION
.750 .003 (19.0) .338 .003 (8.60) .025 (.635) .393 .003 (10.0)
.125 .003 (3.20) 0.10 Typ (2.54) .600 .003 (15.24)
FOOTPRINT AND SCHEMATIC IS PIN FOR PIN EQUIVALENT TO FORMER DPDT MODELS
.082 Typ. (2.09)
.300 .003 (7.62)
.046 Typ. (1.19)
WHEN SPACING DIP RELAYS, EXCEPT FOR THE LATCH VERSION, THE RELAYS REQUIRE 3/4 INCH SPACING FROM THE SIDE OF THE ADJACENT RELAYS. LATCH RELAYS REQUIRE 1 INCH SPACING BETWEEN ADJACENT RELAYS FROM END TO END AND CENTER LINE TO CENTER LINE.
SEE SECTION 10 FOR MATING SOCKET WEBSITE: www.magnecraft.com - EMAIL:info@magnecraft.com - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100 PAGE 72
DIP
DUAL IN-LINE PACKAGE REED RELAY
MIL SPECIFICATION MIL-83516/1 AND /4 VERSIONS AVAILABLE CONSULT FACTORY COIL Measured @ 25C CIRCUIT DIAGRAM TOP VIEW SPST - N.O. 14 13 9 8 W171DIP-2 W171DIP-4 W171DIP-5 5 12 24 3.8 9.0 18.0 0.5 1.0 2.0 500 1200 2200 50 120 270 10VA 0.5 AMP 100VDC 1.5 AMPS
PART NUMBERS
MAXIMUM CONTACT RATING
NOMINAL NOMINAL SWITCHING CONTINUOUS NOMINAL MAXIMUM MINIMUM RESISPOWE LOAD CARRY CURRENT INPUT DROPOUT TANCE PULL-IN (mW) VOLTAGE (OHMS)
CROSS REFERENCE TO HAMLIN HE721A0500 721A1200 721A2400 JWD-171-5 POTTER & BRUMFIELD
12 67 SPST - N.O. WITH CLAMPING DIODE 14 13 9 8 W171DIP-7 W171DIP-9 5 12 24 3.8 9.0 18.0 0.5 1.0 2.0 500 1200 2200 50 120 270 10VA 0.5 AMP 100VDC 721A0510 1.5 AMPS 721A1210 721A2410 JWD-171-10 -
+
12 6 SPST - N.C. 14 13 9 7 8
W171DIP-10
W171DIP-12 W171DIP-14 W171DIP-15
5 12 24
3.8 9.0 18.0
0.5 1.0 2.0
500 1200 2200
50 120 270 10VA 0.5 AMP 100VDC 1.5 AMPS
721B0500 721B1200 721B2400
JWD-171-12 JWD-171-14 JWD-171-15
12 67 SPST - N.C. WITH CLAMPING DIODE 14 13 98 5 W171DIP-17 W171DIP-19 12 24
3.8 9.0 18.0
0.5 1.0 2.0
500 1200 22 00
50 120 270 10VA 0.5 AMP 100VDC 1.5 AMPS
721B0510 721B1210 721B2410
JWD-171-17 JWD-171-19 JWD-171-20
+
12 6 DPST - N.O. 14 13 9 7 8
W171DIP-20
W171DIP-21 W171DIP-23
5 12
3.8 9.0 18.0
0.5 1.0 2.0
125 500 2000
125 300 270
10VA 0.5AMP 100VDC
1.5 AMPS
722A0500 722A1200 722A2400
JWD-171-21 JWD-171-23 JWD-171-24
24 W171DIP-24 12 67 DPST - N.O. WITH CLAMPING DIODE 14 13 9 8 W171DIP-25 W171DIP-27 5 12 24
3.8 9.0 18.0
0.5 1.0 2.0
200 500 2200
125 290 270
10VA 0.5 AMP 100VDC
722A0510 1.5AMPS 722A1210 722A2410
JWD-171-25 JWD-171-27 JWD-171-28
+
12 6
7 W171DIP-28
PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION SEE SPECIFICATIONS AND OUTLINE DIMENSIONS FOR 171DIP
PAGE 73
WEBSITE: www.magnecraft.com - EMAIL:info@magnecraft.com - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
DUAL IN-LINE PACKAGE REED RELAY
DIP
NOMINAL MAXIMUM MINIMUM INPUT PULL-IN DROPOUT VOLTAGE MAGNECRAFT & STRUTHERS-DUNN - SPST-NO LATCHING 14 13
RESET
CIRCUIT DIAGRAM TOP VIEW
COIL Measured @ 25C
PART NUMBERS
MAXIMUM CONTACT RATING CROSS NOMINAL NOMINAL SWITCHING CONTINUOUS RESISPOWER TANCE LOAD CARRY CURRENT HAMLIN (mW) (OHMS) HE-
REFERENCE TO POTTER & BRUMFIELD
9
+
8 MRRDL1AS8-5D MRRDL1AS8-12D 5 12 24 3.8 9.0 18.0 0.5 1.0 2.0 750 1000 4600 35 145 125 10VA 0.5AMP 100VDC
1.5 AMPS
+
12 SPDT 14 13 9 8 6 7
OPERATE
MRRDL1AS8-24D
W172DIP-141 W172DIP-145 W172DIP-146 1 2 6 9 7 8 W172DIP-147 W172DIP-149 1 SPDT WITH CLAMPING DIODE 14 13
5 12 24
3.8 9.0 18.0
0.5 1.0 2.0
200 1000 2200
125 144 180
721C0500 4VA .25 AMP 100VDC 0.5AMPS 721C1200 721C2400
JWD-172-155 JWD-172-157 JWD-172-158
5 12 24
3.8 9.0 18.0
0.5 1.0 2.0
200 1000 2200
125 144 180 4VA .25 AMP 100VDC 0.5AMPS
721C0510 721C1210 721C2410
JWD-172-159 JWD-172-161 JWD-172-162
+
2
6 9
7 8
W172DIP-150
SPDT 14 13
W172DIP-31 W172DIP-33 W172DIP-34 67 12 SPDT WITH CLAMPING DIODE 14 13 98 W172DIP-35 W172DIP-37
5 12 24
3.8 9.0 18.0
0.5 1.0 2.0
500 1000 2200
125 290 270 4VA .25 AMP 100VDC 0.5AMPS
721E0500 721E1200 721E2400
-
5 12 24
3.8 9.0 18.0
0.5 1.0 2.0
500 1000 2200
125 300 270 4VA .25 AMP 100VDC 0.5 AMPS
721E0510 721E1210 721E2410
-
+
1 2 6 7
W172DIP-38
PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION
WEBSITE: www.magnecraft.com - EMAIL:info@magnecraft.com - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
PAGE 74
DIP
DUAL IN-LINE PACKAGE REED RELAY
171 & 172 (SPDT)
CIRCUIT DIAGRAM TOP VIEW SPDT 14 13 9 8
COIL Measured @ 25C PART NUMBERS
MAXIMUM CONTACT RATING
NOMINAL NOMINAL NOMINAL SWITCHING CONTINUOUS MAXIMUM MINIMUM RESISPOWER INPUT LOAD CARRY CURRENT PULL-IN DROPOUT TANCE (mW) VOLTAGE (OHMS)
CROSS REFERENCE TO HAMLIN HEPOTTER & BRUMFIELD
W172DIP-1 W172DIP-3 W172DIP-4 1 2 6 7
5 12 24
3.8 9.0 18.0
0.5 1.0 2.0
200 500 2200
125 300 270 4VA .25 AMP 100VDC 0.5 AMPS
721R0500 721R1200 721R2400
JWD-172-1 JWD-172-3 JWD-172-4
SPDT WITH CLAMPING DIODE 14 13 9 8 W172DIP-5 W172DIP-7 1 5 12 24 3.8 9.0 18.0 0.5 1.0 2.0 200 500 2200 125 300 270 4VA .25 AMP 100VDC 0.5 AMPS 721R2410 721R0510 721R1210 JWD-172-5 JWD-172-7 JWD-172-8
+
2
6
7
W172DIP-8
SEE SPECIFICATIONS AND OUTLINE DIMENSIONS FOR 172DIP (SPDT)
PACKAGE STYLE FOR W172 DIPS DPDT CIRCUIT DIAGRAM TOP VIEW DPDT 14 13 9 8 W172DIP-17 W172DIP-19 W172DIP-20 12 6 7 5 12 24 3.8 9.0 18.0 0.3 0.3 0.3 46 266 1066 540 540 540 10VA 0.5 AMP 100VDC 1.0 AMPS 172 DIPS WITH DPDT CONTACT ARRANGEMENTS HAVE A NEW PACKAGE STYLE. NEW PACKAGE SWITCHES HIGHER CURRENT UP TO 0.5 AMP @ 100 VDC COIL Measured @ 25C PART NUMBERS MAXIMUM CONTACT RATING
NOMINAL NOMINAL NOMINAL SWITCHING CONTINUOUS MAXIMUM MINIMUM RESISPOWER INPUT LOAD CARRY CURRENT PULL-IN DROPOUT TANCE (mW) VOLTAGE (OHMS)
DPDT WITH CLAMPING DIODE 14 13 9 8 W172DIP-21 W172DIP-23 W172DIP-24 5 12 24 3.8 9.0 18.0 0.3 0.3 0.3 46 266 1066 540 540 540 10VA 0.5 AMP 100VDC 1.0 AMPS
+ 12
6
7
SEE SPECIFICATIONS AND OUTLINE DIMENSIONS FOR 172DIP (DPDT) PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION
PAGE 75
WEBSITE: www.magnecraft.com - EMAIL:info@magnecraft.com - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
GENERAL SPECIFICATIONS MINIATURE REED RELAYS
OUTLINE DIMENSIONS
1.15 Max. (29.2) .355 (9.0) 1.00 (25.4) .125 (3.2) Typ. DIMENSIONS SHOWN ARE IN INCHES AND ( MILLIMETERS )
MINIATURE
REED
Slotted holes for Terminal Pins. SIZE IV
.900 (22.86)
SIZE I
.050 (1.27) Typ. .075 (1.9)
.400 (10.16)
SIZE II
.500 (12.7)
SIZE III
.700 (17.8)
.100 (2.54) Typ.
BOTTOM VIEW ALL SIZES
STANDARD PRINTED CIRCUIT RELAY HAS 1.00" X 0.1" GRID SPACING SIZE I RELAY CLASS CONTACT CONFIGURATION: 101/193 SPST-NO SPST-NO Latching (SPST-NO) 3PST-NO Latching up to 6PST-NO 10 VA 200DC/130 AC 0.5 AMPS 2 AMPS 104/193 SPDT, DPDT for 104 Series SPDT,DPDT, 3PDT,4PDT (193 Series) 4VA 100 VDC 0.5 AMPS 1 AMPS 131 SPST-NO or DPST-NO Mercury 134 Mercury (SPDT) Mercury DPDT
SIZE II CONTACT RATING MAX. (Resistive Load): SWITCHING VOLTAGE MAX. SWITCHING CURRENT MAX. CARRY CURRENT MAX. INITIAL CONTACT RESISTANCE ( IN MILLIOHMS ): INSULATION RESISTANCE (Ohms) TESTED AT 100 VDC: SIZE III DIELECTRIC STRENGTH: MIN. ACROSS OPEN CONTACTS: MIN. BETWEEN MUTUALLY INSULATED POINTS: CAPACITANCE: ( non-shielded relay) ACROSS OPEN CONTACTS: OPEN CONTACTS TO COIL: CLOSED CONTACTS TO COIL: TEMPERATURE: MAX. AMBIENT OPERATING (C ) TEMPERATURE: MIN. AMBIENT OPERATING ( C ) STORAGE TEMPERATURE: MOUNTING POSITION: LIFE AT RATED LOAD: With appropriate Contact protection ( End of life 1 Ohm ) OPERATE TIME: (Typical- in Micro-Sec.]).
50VA 500 VDC 2 AMPS 3 AMPS
50VA 500 VDC 2 AMPS 3 AMPS
200 Milliohms Max.
100 Milliohms Max. Contact resistance Stability 10% over Life. 1010 Min. 1010 Min.
109 Min.
200 VDC 500 VDC
1000 VDC 1000 VDC
1000 VDC 1000 VDC
.
3pf Typical Form "A" 2.0 pF Typ. Form "C" 3.0pF Typ.
.3pF 2.0 pF 3.0pF
.9pF 2.0 pF 2.5pF
SIZE IV
85 C or ( 120 C -70 x [ Coil Power]) whichever is lower - 40C - 60C to + 105C ANY 10 Million Operations 100 Million Operations at Low level 1.0 mS, for N.O. 1.0 mS, for N.C. - 37C - 40C to + 105C Vertical 15 40 x 108 3 x 108 at low level 2.0 mS, for N.O. 50 x 108 5 x 108 at low level 2300 S 2000 S
TYPICAL RELEASE TIME: (in Micro-Sec.) Diode Suppression: No Suppression: PACKAGING:
1.0 mS, for N.O. 1.5 mS, for N.C.
1.0 mS for NO 1.5 mS for NC
2.0 mS 2.5 mS
Dust covered, Epoxy Encapsulated is Standard.
WEBSITE: www.magnecraft.com - EMAIL:info@magnecraft.com - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
PAGE 76
MINIATURE
REED
SIZE I
CLASS 101 DRY MINIATURE REED RELAY
PIN SPACING OF 0.100" IS STANDARD. PIN SPACING OF 0.150 IS AVAILABLE ON SPECIAL ORDER. ALSO AVAILABLE ARE MODELS WITH ELECTROSTATIC SHIELDS. CONSULT FACTORY FOR PART NUMBERS. NON-STANDARD SCHEMATICS AND PIN-OUTS CAN ALSO BE PRODUCED FOR SPECIFIC CUSTOMER REQUIREMENTS. Spacing between filled in circles in schematics are on a .100 Grid Pattern. Pin omitted on unfilled circles.
.100 (2.54) Typ.
SIZE III
COIL MEASURED AT 25C CASE SIZE CIRCUIT DIAGRAM TOP VIEW PART NUMBERS
MAX. CONTACT RATING
NOMINAL MAXIMUM MINIMUM NOMINAL NOMINAL MAX. SWITCHING POWER SWITCHING CURRENT & CARRY INPUT PULL-IN DROPOUT RESISTANCE CURRENT (mW) VOLTAGE LOAD VOLTAGE (OHMS)
SPST-NO
5 6
I
1 2
W101MPCX-2 W101MPCX-3
12 24
9.0 18.0
1.0 2.0
1400 3300
102 175
10 VA
0.5 AMP 200 VDC
2 AMPS
3PST-NO
11 12
III
W101MPCX-5 W101MPCX-6 W101MPCX-7
5 12 24
4.0 9.0 18.0
0.5 1.0 2.0
90 430 1500
280 340 380
10 VA
0.5 AMP 200 VDC
2 AMPS
1
2
SPST-NO MAGNETIC LATCH
11 De-Latch (Reset) + 12
III
Latch (Set) 1
W101LMPCX-16 W101LMPCX-17
5/5 12/12
3.8 9.0 To Set or Reset
-
425/425 2500/2500
60 60
10 VA
0.5 AMP 200 VDC
2 AMPS
+ 2
PART NUMBERS SHOWN AVAILABLE THRU STOCKING DISTRIBUTION
PAGE 77
WEBSITE: www.magnecraft.com - EMAIL:info@magnecraft.com - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
CLASS 131 MERCURY
PIN SPACING OF 0.100" IS STANDARD. PIN SPACING OF 0.150 IS AVAILABLE ON SPECIAL ORDER. ALSO AVAILABLE ARE MODELS WITH ELECTROSTATIC SHIELDS. CONSULT FACTORY FOR PART NUMBERS. NON-STANDARD SCHEMATICS AND PIN-OUTS CAN ALSO BE PRODUCED FOR SPECIFIC CUSTOMER REQUIREMENTS.
MINIATURE
REED
SIZE I
Spacing between filled in circles in schematics are on a .100 Grid Pattern. Pin omitted on unfilled circles.
.100 (2.54) Typ.
SIZE II
SPST-NO MERCURY
5 UP 6
1
1 2
W131MPCX-3 W131MPCX-4
12 24
9.0 18.0
1.0 2.0
330 1400
435 410
50 VA
2.0 AMP 500 VDC
3 AMPS
DPST-NO MERCURY
UP 9 10
I I
W131MPCX-7 W131MPCX-8
12 24
9.0 18.0
1.0 2.0
230 1200
626 480
50 VA
2.0 AMP 500 VDC
3 AMPS
1
2
PART NUMBERS SHOWN AVAILABLE THRU STOCKING DISTRIBUTION
For Class 131 allow a minimum of 30 seconds after mounting for excess Mercury to clear from the contacts before using.
WEBSITE: www.magnecraft.com - EMAIL:info@magnecraft.com - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
PAGE 78
MINIATURE
REED
SIZE I
CLASS 104 DRY MINIATURE REED RELAY
PIN SPACING OF .100" IS STANDARD. PIN SPACING OF .150 IS AVAILABLE ON SPECIAL ORDER. ALSO AVAILABLE ARE MODELS WITH ELECTROSTATIC SHIELDS. CONSULT FACTORY FOR PART NUMBERS. NONSTANDARD SCHEMATICS AND PIN-OUTS CAN ALSO BE PRODUCED FOR SPECIFIC CUSTOMER REQUIREMENTS. Spacing between filled in circles in schematics are on a .100 Grid Pattern. Pin omitted on unfilled circles. SIZE III
.100 (2.54) Typ.
CASE SIZE
CIRCUIT DIAGRAM TOP VIEW
PART NUMBERS
COIL MEASURED AT 25C MAX. CONTACT RATING NOMINAL MAXIMUM MINIMUM NOMINAL NOMINAL MAX. SWITCHING POWER SWITCHING CURRENT & CARRY INPUT PULL-IN DROPOUT RESISTANCE CURRENT (mW) VOLTAGE LOAD VOLTAGE (OHMS)
SPDT
5 6
I
1 2
W104MPCX-3
24
18.0
2.0
2600
220
4 VA
0.25 AMP 100VDC
0.5 AMPS
DPDT
9 10
I I
W104MPCX-6
12
9.0
1.0
230
626
4 VA
0.25 AMP 100VDC
0.5 AMPS
1
2
DPDT
7 8
I I
1 2
W104MPCX-149 W104MPCX-150 W104MPCX-151
5 12 24
4.0 9.0 18.0
0.5 1.0 2.0
45 230 1200
556 626 480
4 VA
0.25 AMP 100VDC
0.5 AMPS
PART NUMBERS SHOWN AVAILABLE THRU STOCKING DISTRIBUTION
PAGE 79
WEBSITE: www.magnecraft.com - EMAIL:info@magnecraft.com - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
MINIATURE
CLASS 134 MERCURY
PIN SPACING OF .100" IS STANDARD. PIN SPACING OF .150 IS AVAILABLE ON SPECIAL ORDER. ALSO AVAILABLE ARE MODELS WITH ELECTROSTATIC SHIELDS. CONSULT FACTORY FOR PART NUMBERS. NONSTANDARD SCHEMATICS AND PIN-OUTS CAN ALSO BE PRODUCED FOR SPECIFIC CUSTOMER REQUIREMENTS. Spacing between filled in circles in schematics are on a .100 Grid Pattern. Pin omitted on unfilled circles.
.100 (2.54) Typ.
REED
SIZE I
SIZE II
DPDT MERCURY
UP 7 8
I I
1 2
W134MPCX-7 W134MPCX-8
5 12
4.0 9.6
0.5 1.0
45 230
560 620
50 VA
1.0 AMP 500 VDC
2.0 AMPS
DPDT MERCURY WITH CLAMPING DIODE
+ I I
1 2 UP 7 8
W134MPCX-10 W134MPCX-11 -
5 12
4.0 9.6
1.0 1.0
45 230
560 620
50 VA
1.0 AMP 500 VDC
2.0 AMPS
SPDT MERCURY
5 UP 6
I
1 2
W134MPCX-1 W134MPCX-2 W134MPCX-3
5 12 24
4.0 9.0 18.0
0.5 1.0 2.0
60 330 1400
417 435 410
50 VA
1.0 AMP 500 VDC
2.0 AMPS
PART NUMBERS SHOWN AVAILABLE THRU STOCKING DISTRIBUTION
For Class 134 allow a minimum of 30 seconds after mounting for excess Mercury to clear from the contacts before using.
WEBSITE: www.magnecraft.com - EMAIL:info@magnecraft.com - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
PAGE 80
MINIATURE
REED
SIZE I
CLASS 193 DRY MINIATURE REED RELAY
PIN SPACING OF 0.100" IS STANDARD. PIN SPACING OF 0.150 IS AVAILABLE ON SPECIAL ORDER. ALSO AVAILABLE ARE MODELS WITH ELECTROSTATIC SHIELDS. CONSULT FACTORY FOR PART NUMBERS. NONSTANDARD SCHEMATICS AND PIN-OUTS CAN ALSO BE PRODUCED FOR SPECIFIC CUSTOMER REQUIREMENTS.
Spacing between filled in circles in schematics are on .100 Grid Patterns. Pin omitted on unfilled circles.
.100 (2.54) Typ.
SIZE II
CASE SIZE
CIRCUIT DIAGRAM (Top View)
PART NUMBERS
COIL MEASURED AT 25C MAX. CONTACT RATING NOMINAL NOMINAL MAX. NOMINAL MAXIMUM MINIMUM SWITCHING CARRY POWER SWITCHING CURRENT & INPUT PULL-IN DROPOUT RESISCURRENT TANCE (mW) VOLTAGE VOLTAGE LOAD (OHMS)
SPST-N.O.
I
1 3 5 2 W193RE1A3-5S 4
W193RE1A3-12G 6 W193RE1A3-24G
5 12 24
4.0 9.0 18.0
0.5 1.0 2.0
500 420 2300
50 350 250
10 VA
0.5 AMP 200 VDC
2 AMPS
SPDT
I
1 3 5 2 4 6
W193RE1C3-5S W193RE1C3-12G W193RE1C3-24G
5 12 24 5 12 24
4.0 9.0 18.0
0.5 1.0 2.0
350 420 2300
70 350 250 4 VA
0.5 AMP 100 VDC
1 AMP
DPST-N.O.
I I
1 3 5 7 2 W193RE2A3-6G 4 6 W193RE2A3-12G 8
4.0 9.0 18.0
0.5 1.0 2.0
70 280 1500
360 500 390 10 VA 0.5 AMP 200 VDC 2 AMP
W193RE2A3-24G
DPDT
I I
1 3 5 7 2 W193RE2C3-6G 4 6 W193RE2C3-12G 8
5 12 24
4.0 9.0 18.0
0.5 1.0 2.0
70 280 1500
360 500 390 4 VA 0.5 AMP 100 VDC 1 AMP
W193RE2C3-24G
PART NUMBERS SHOWN AVAILABLE THRU STOCKING DISTRIBUTION
PAGE 81
WEBSITE: www.magnecraft.com - EMAIL:info@magnecraft.com - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
CLASS 193 DRY MINIATURE REED RELAY
PIN SPACING OF 0.100" IS STANDARD. PIN SPACING OF 0.150 IS AVAILABLE ON SPECIAL ORDER. ALSO AVAILABLE ARE MODELS WITH ELECTROSTATIC SHIELDS. CONSULT FACTORY FOR PART NUMBERS. NONSTANDARD SCHEMATICS AND PIN-OUTS CAN ALSO BE PRODUCED FOR SPECIFIC CUSTOMER REQUIREMENTS.
MINIATURE
REED
SIZE III
Spacing between filled in circles in schematics are on .100 Grid Patterns. Pin omitted on unfilled circles.
.100 (2.54) Typ.
SIZE IV
CASE SIZE
CIRCUIT DIAGRAM (Top View)
PART NUMBERS
MAX. CONTACT RATING COIL MEASURED AT 25C NOMINAL NOMINAL MAX. NOMINAL MAXIMUM MINIMUM SWITCHING CARRY POWER SWITCHING CURRENT & INPUT PULL-IN DROPOUT RESISCURRENT TANCE (mW) VOLTAGE VOLTAGE LOAD (OHMS)
3PST-N.O.
1 3 2 4 6 8 10
W193RE3A3-6G W193RE3A3-12G W193RE3A3-24G
5 12 24
4.0 9.0 18.0
0.5 1.0 2.0
50 210 1150
500 690 500 10 VA 0.5 AMP 200 VDC 2 AMP
III
5 7 9
3PDT
1 3
III
5 7 9 11
2 4 6 8 10 12
W193RE3C3-6G W193RE3C3-12G W193RE3C3-24G
5 12 24
4.0 9.0 18.0
0.5 1.0 2.0
50 210 1150
500 690 500 4 VA 0.5 AMP 100 VDC 1 AMP
4PST-N.O.
III
1 3 5 7 9 11 2 4 6 8 10 12
W193RE4A3-6G W193RE4A3-12G W193RE4A3-24G
5 12 24
4.0 9.0 18.0
0.5 1.0 2.0
50 210 1150
500 690 500 10 VA 0.5 AMP 200 VDC 2 AMP
4PDT
1 3 5 7 2 4 6 8 10 12 14 16
W193RE4C3-6G W193RE4C3-12G W193RE4C3-24G
5 12 24
4.0 9.0 18.0
0.5 1.0 2.0
35 140 770
720 1030 750 4 VA 0.5 AMP 100 VDC 1 AMP
IV
9 11 13 15
PART NUMBERS SHOWN AVAILABLE THRU STOCKING DISTRIBUTION
WEBSITE: www.magnecraft.com - EMAIL:info@magnecraft.com - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
PAGE 82
SERIES
MR-Y
P.C. TERMINAL, MOLDED MINIATURE REED RELAY
The MR-Y Series epoxy molded miniature reed relay has terminal pins on each end and spaced 1 inch apart. It is available with two grid spacings - 0.1 inch or 0.15 inch. Available contacts range from SPST-NO to DPDT configurations. As an option, Mercury reeds are available in limited contact configurations. Lower power coils are also available in addition to optional diode across the coil and electrostatic shielding.
WIRING DIAGRAM
Top View
+
SPST-NO MR30Y1A MR35Y1A
*
+
SPST-NC MR30Y1B MR35Y1B
+ * *
SPDT MR30Y1C MR35Y1C DPDT MR30Y2C MR35Y2C
+
*
DPST-NO MR30Y2A MR35Y2A
+
OUTLINE DIMENSIONS
Dimensions shown are in Inches and (Millimeter)
.950 (24.1)
.400 (10.1)
.550 (13.9)
.312 (7.9)
.130 (3.3) .010 (.254) .045 Typ. (1.14) .020 Typ. (.508) DIM. "A" SEE CHART DIM. "B" SEE CHART
Position Reference
.062 R x .032 Deep
DIMENSION CHART DIM "A" 0.100 0.10 Grid DIM."A" 0.150 0.15 Grid DIM "B" 0.200 0.10 Grid DIM."B" 0.300 0.15 Grid
1.00 (25.4)
PAGE 83
WEBSITE: www.magnecraft.com - EMAIL:info@magnecraft.com - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
SERIES
P.C. TERMINAL, MOLDED MINIATURE REED RELAY
SPECIFICATIONS MR-Y (Not all Data applies to HG Relays)
Package Material: Contact Material: Dielectric Strength:
MR-Y
Epoxy, molded Rhodium 200 V rms Across Open Contacts 1500 V rms All other points Insulation Resistance: 1000 Megohms Min. Capacitance: 0.4 pF typical coil to contacts Shock Resistance: 50 G's Vibration Resistance: 20 G's to 2000 Hz Operate & Release Time: 2 Milliseconds Max. Life: 10 Million operations at rated load SPST,DPST-NO & NC 100 Million operations no load SPST,DPST-NO & NC 5 Million operations at rated load SPDT, DPDT contacts. 50 Million operations no load, SPDT, DPDT contacts.
COIL DATA Power Consumption (mW) - Coil Resistance, Nominal Voltage 10% @ 25C SPST, DPST SPDT, DPDT VDC OHMS mW mW OHMS 167 5 313 150 80 12 250 450 575 320 24 268 384 2150 1500 Must operate at 80% of nominal voltage @ 25C Low Power Coils available: Single Pole - 25mW Double Pole - 65mW
CONTACT DATA Material - Rhodium on Dry Reeds Max. VDC Contacts 200 SPST-NO 200 SPST-NC 28 SPDT, DPDT 500 SPST-NO (HG) 200 SPDT, DPDT(HG) Max. mA 500 500 250 2000 1000 VA 10 10 3 50 28
Struthers-Dunn
ORDERING CODE Typical Type No.
MR30Y
2A
RV -12D
Series MR30Y- 0.1 grid, end terminal Min. P.C. Reed Relay MR35Y- 0.15 grid, end terminal Min. P.C. Reed Relay Contact Arrangements 1A - SPST-NO 2A - DPST-NO 1B - SPST-NC 1C - SPDT 2C - DPDT Options Electrostatic Shield (see wiring diagrams)- CODE E Low Power Coils (Dry Reeds Only) - CODE R Diode across Coil (Observe Polarity) - CODE V Mercury Reed Contact, position sensitive SPST-NO or SPDT - CODE Z Coil Voltage (DC only) DC: 5, 12, 24 (Add "D") + Polarity must be observed for models with Form "B" contacts or optional Diode.
*Terminal
HG
for optional Electrostatic Shield. Contact relays are position sensitive.
WEBSITE: www.magnecraft.com - EMAIL:info@magnecraft.com - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
PAGE 84
SERIES
MRR & RR
AXIAL LEAD, SHIELDED REED RELAY
The MRR and RR Series Axial lead epoxy molded reed relays have solid wire leads on each end. They are available with two grid spacings - 0.1 inch for the MRR series and 0.2 inch for the RR series. Available contacts - UP TO 12PSTNO for the MRR series, and 1 -4PST-NO or NC for the RR series. The MRR and RR series come with an external Half shield fixed to the body of the relay.
WIRING DIAGRAM (Terminal view )
MRR4A, RR4AF MRR3A, RR3A MRR2A, RR2A MRR1A, RR1A
RR1B
DIMENSIONAL CHART FOR MRR & RR SERIES RELAYS SERIES A MRR1A MRR2A MRR4A RR1A, RR1B RR2A RR4AF B C DIMENSIONS (Inches) D E F G H
1.062 .425 .425 .018 X .030 .005 .440 .515 .500 .500 .028 .028 .535 .810 .655 .655 .055 1.875 .670 .840 .875 .500 .035 .035 X .061 .810 1.385
To convert Inch dimensions to Millimeter use 25.4 x Dimension = Millimeters.
OUTLINE DIMENSIONS
See dimensional chart above F MRR4A, RR4AF
H
C
Max.
F H
MRR2A, RR2A
G
Max.
B
C
Max.
F H
MRR1A, RR1A, RR1B
G G
Max.
B
Min.
Min.
D
A
Typical Lead spacing .115" Typical Lead spacing .115"
E
Max.
B
PAGE 85
WEBSITE: www.magnecraft.com - EMAIL:info@magnecraft.com - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
SERIES
AXIAL LEAD, SHIELDED REED RELAY
SPECIFICATIONS MRR & RR
Contact Material: Ambient Temperature: Dielectric Strength: Rhodium - 40C to + 85C MRR 400 V rms Across open contacts RR 500 V rms Across open contacts 1500 V rms All other points 1000 Megohms Min. 0.4 pF typical coil to contacts 50 G's MRR - 20 G's to 2000 Hz RR - 10 G's to 450 Hz 2 to 10 Milliseconds based on the amount of contacts. 10 Million operations at rated load 200 Million operations no load
MRR & RR
Insulation Resistance: Capacitance: Shock Resistance: Vibration Resistance: Operate & Release Time: Life:
COIL DATA MRR SERIES Coil Resistance & Nominal Voltage Measured at 10% @ 25C. SPST-NO DPST-NO 4PST-NO 12PST-NO OHMS OHMS VDC OHMS OHMS 24 72 6 144 288 94 288 12 576 1152 384 1152 24 2300 4600 1536 3300 48
Must operate at 70% of nominal voltage @ 25C
COIL DATA RR SERIES Coil Resistance & Nominal Voltage Measured at 10% @ 25C. DPST-NO 4PST-NO SPST-NO or NC OHMS OHMS OHMS VDC 24 90 36 6 94 360 145 12 384 1440 580 24 1536 5760 2300 48
Must operate at 80% of nominal voltage @ 25C
Options RR only - Preformed leads welded lead extensions. CONTACT DATA MRR SERIES Material - Rhodium on Dry Reeds Contacts 1-4PST-NO Max. VDC 200 Max. mA 500 VA 10 CONTACT DATA RR SERIES Material - Rhodium on Dry Reeds Contacts 1-4PST-NO SPST-NC Max. VDC 250 250 Max. AMPS 1.0 1.0 VA 15 15
NOTE: Voltage, Current, and Power ratings in the tables above are independent maximums and no single value is to be exceeded. Ratings are based on noninductive, straight resistive, AC or DC loads without inrush. Other loads require contact protection and /or de-rating.
Struthers-Dunn
ORDERING CODE Typical Type No. Series MRR- 0.1" Lead spacing RR- 0.2" Lead spacing Contact Arrangements 1A - SPST-NO 2A - DPST-NO 3A - 3PST-NO 4A - 4PST-NO 1B - SPST-NC (RR series Only) Coil Voltage (DC only) DC: 6, 12, 24, 48 (Add "D") (5 volt and other voltages available)
MRR or RR 2A
-12D
WEBSITE: www.magnecraft.com - EMAIL:info@magnecraft.com - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
PAGE 86
series
RRN
OPEN STYLE, METAL COVER/SHIELD REED RELAY
The RRN Series is a open construction, one piece nylon bobbin, P.C. terminal assembly with a metal Cover/Shield (3 sided).
* WIRING DIAGRAMS (Top View) RRN1A
.740 Wide
RRN2A
.958 Wide
RRN3A
1.188 Wide
RRN1C
.740 Wide
RRN1B
.958 Wide +
RRN2B
1.188 Wide
+
RRN4A
1.418 Wide
RRN2C
1.418 Wide
RRN3C
1.418 Wide
OUTLINE DIMENSIONS
Shown in Inchs and (Millimeters)
2.50 Max. (63.5) .64 Max. (16.2)
* See Wiring Diagrams for Width. *
0.156 (3.9)
1.90 Max. (48.2)
.38 (9.6) .200 (5.0)
0.10 (2.54)
.800 (20.3) .500 (12.7)
2 POLE CASE SIZE Terminals on 0.2 Inch grid. The 1 and 3 pole units have the middle terminals on the center line.
PAGE 87
WEBSITE: www.magnecraft.com - EMAIL:info@magnecraft.com - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
series
OPEN STYLE, METAL COVER/SHIELD REED RELAY
RRN
SPECIFICATIONS RRN
Contact Material: Ambient Temperature: Dielectric Strength: Insulation Resistance: Capacitance: Shock Resistance: Vibration Resistance: Operate Time: Release Time: Life: Rhodium - 40C to + 85C 500 V rms Across open contacts 1500 V rms All other points 1000 Megohms Min. 0.4 pF typical coil to contacts 50 G's RR - 10 G's to 450 Hz 6 Milliseconds max. depending on 6 Milliseconds worst case. 10 Million operations at rated load 200 Million operations no load all 1-4PST-NO & SPST-NC 50 Million Operations at no load for all SPDT, DPDT Contacts.
COIL DATA Coil Resistance & Nominal Voltage Measured at 10% @ 25C NOM. VDC 6 12 24 48 1 POLE OHMS 150 600 2400 4000 2 POLE OHMS 100 400 1600 4000 3 POLE OHMS 50 200 800 3000 4 POLE OHMS 40 150 600 2300
CONTACT DATA Contacts Max. VDC 1-4PST-NO 250 1-2PST-NC 250 SPDT, DPDT 250
Max. Amps 1.0 1.0 0.5
VA 15 15 10
Must operate at 80% of nominal voltage @ 25C
NOTE: Voltage, Current, and Power ratings in the table above are independent maximums and no single value is to be exceeded. Ratings are based on noninductive, straight resistive, AC or DC loads without inrush. Other loads require contact protection or de-rating.
Struthers-Dunn
ORDERING CODE Typical Type No.
RRN
3A
EV
-12D
Series RRN- Semi open, 3 sided shield Contact Arrangements 1A - SPST-NO 2A - DPST-NO 3A - 3PST-NO 4A - 4PST-NO 1B - SPST-NC 2B -DPST-NC 1C - SPDT 2C - DPDT Options Electrostatic Shield (Consult Factory For Wiring Code E Diode Across Coil (Observe Polarity, Consult Factory) Code V Coil Voltage (DC only) DC: 6, 12, 24, 48 (Add "D") (5 volt and other voltages available)
SPECIAL OPTIONS
Special Wiring . Magnetic Latch Version . Consult Factory
WEBSITE: www.magnecraft.com - EMAIL:info@magnecraft.com - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
PAGE 88
CLASS
102
OPEN STYLE, METAL COVER/SHIELD REED RELAY
102MPCX/RMPCX
SPST-N.O. METAL SHIELD ON THREE SIDES. 0.2 GRID SPACING. OUTLINE DIMENSIONS
Dimensions shown are in Inch and (Millimeter)
2.67 Max. (16.5) .65 Max. (16.5) 1.90 Max. (48.2) .38 (9.6) .200 (5.0) .18 Max. (4.5) .760 Max. (19.3)
0.16 (4.0)
.400 (10.1)
1 POLE CASE SIZE
GENERAL SPECIFICATIONS 102
102 102R RELAY CLASS Contact Resistance Initial: 200 200 Dielectric Withstanding voltage: Across Open Contacts: 700 VDC 450 VDC Between all other mutually Insulated points.: 1000 VDC Operate Time (mS): Bounce Time No Diode (mS): 1.0 2 2.0 2 RELAY CLASS Capacitance, Non Shield, N.O.: Insulation Resistance: Coil Dissipation (mW) Mounting Position: Shock (Non operation): Vibration: Temperature Range (operating): Life At rated load: 102 102R 1.0 pf 1.5 pf 109 at 100 VDC 50 to 1.5W 600 Any 30 G's 11mS 1 mS 1/2 Sign 10 G"s 10 to 1000 Hz -40C to + 85C 200 Million 20 Million @1A, 115V rms
CIRCUIT DIAGRAM (TOP VIEW)
PART NUMBERS
COIL MEASURED AT 25C MAX. CONTACT RATING NOMINAL MAXIMUM MINIMUM NOMINAL NOMINAL SWITCHING SWITCHING CARRY RESISINPUT PULL-IN DROPOUT TANCE POWER CURRENT & LOAD CURRENT (mW) VOLTAGE VOLTAGE (OHMS)
SPST-N.O. 1 AMP
W102MPCX-7 W102MPCX-8 12 24 9.0 18.0 1.0 2.0 250 1000 580 mW 15VA 1 AMP 250VDC 2 AMPS
SPST-N.O. 3 AMP
W102RMPCX-2 W102RMPCX-3 12 24 9.0 18.0 1.0 2.0 250 580 mW 1000 100VA 3 AMP 250VDC 3.5 AMPS
PART NUMBERS SHOWN AVAILABLE THRU STOCKING DISTRIBUTION
PAGE 89
WEBSITE: www.magnecraft.com - EMAIL:info@magnecraft.com - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
150 WATT, COAXIAL R.F. SWITCHING RELAY
120 COAXIAL RELAY
PANEL MOUNT WITH RG58C/U CABLE (50 OHM ) SWITCHING UP TO 470 MHz
1.73 (44.0) RG58C/U 12.0 (304.8) .120 Dia thru holes (2 mounting holes) RG58C/U .671 (17.0)
CLASS
120
.312 (7.93)
1.106 (29.05)
12.0 (304.8)
.422 .770 (10.71) (19.5) .250 Typ. (6.35)
WIRING DIAGRAM
Side View Coil Down 2 1 3 4
.850 (21.59)
.078 (1.98)
.093 (2.38)
1.28 (32.5)
GENERAL SPECIFICATIONS CLASS 120
CONTACTS R.F. Load rating: Contact Configuration: Contact Resistance (Initial): VSWR ( Voltage Standing Wave Ratio) Cross Talk: TIMING Operate Time: Release Time: DIELECTRIC STRENGTH All Mutually Insulated current carrying parts to ground: Insulation Resistance: TEMPERATURE Rated Operation: LIFE EXPECTANCY Mechanical: Electrical: MISCELLANEOUS Mounting: Connectors: Cable Type: Cable Impedance: Weight: 150 Watts max. up to 470 MHz SPDT (1 Form "C") 50 Milliohms max. 1.25 to 1 max., up to 460 MHz 40 DB min., up to 470 MHz. 15 mS Max. @ Nominal Voltage. 7 mS Max. @ Nominal Voltage.
5
1000 V rms @ Sea level 1000 Megohms min. 500 V -55C to +65C
100,000 Operations @ Rated Load. 5 Million Operations no load Panel mount with 2 mount holes. None RG58C/U, 12" long, with stripped wire length of .250" 50 Ohms 3 ozs. 85.0 grams approx.
COIL Measured @ 25C PART NUMBER CONTACT CONFIGURATION DC OPERATED W120X-14 SPDT 12 VDC 100 NOMINAL INPUT VOLTAGE NOMINAL RESISTANCE (OHMS)
PART NUMBERS SHOWN AVAILABLE THRU STOCKING DISTRIBUTION
WEBSITE: www.magnecraft.com - EMAIL:info@magnecraft.com - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
PAGE 90
Page 91
SECTION
4
4
SOLID STATE RELAYS (SSR) 1.5 TO 75 AMPERES
Magnecraft
Struthers-Dunn
SOLID STATE RELAYS
RELAY SERIES
226
230E & 230T
231
CLASS 6 (DTX)
NEW!
L.E.D.
L.E.D INDICATES RELAY IS IN THE OPERATE MODE.
L.E.D. "ON" LAMP
5 OR 12 VDC INPUT AC, TRIAC OUTPUT UP TO 7 AMP LOADS PHOTO ISOLATED, RANDOM TURN-ON COMPATABLE WITH TTL GATES. MOUNTS ON TO-3 TRANSISTOR HEAT SINKS FOR ADDED CURRENT RATING. P.C. MOUNT STYLE. 5 OR 12 VDC INPUT AC OUTPUT TYPE 230E HAS 1.5 AMP LOAD RATING TYPE 230T HAS 3.0 AMP LOAD RATING ZERO VOLTAGE SWITCHING. TYPE 230T HAS BUILT IN HEAT SINK. SPST-NO 1.5 AMPS @ 140 OR 280VAC (230E) SPST-NO 3.0AMPS @ 140 OR 280 VAC (230T) SCR 25 MILLIAMPS SCR 25MILLIAMPS TRIAC 50 MILLIAMPS Q.C. TERMINAL, FLANGE MOUNT STYLE. 5 OR 12 VDC INPUT AC OUTPUT UP TO 4 AMP LOADS. ZERO VOLTAGE SWITCHING. FLANGE ALSO SERVES AS THE HEAT SINK. DC CONTROLLED INPUT, AC TRIAC OUTPUT UP TO 10 AMP LOADS PHOTO ISOLATED, ZERO VOLTAGE SWITCHING. 4000 V rms ISOLATION INPUT TO OUTPUT. INTERNAL RC (SNUBBER) NETWORK SPST-NO 10 AMPS @ 140 OR 280 VAC
FEATURES
OUTPUT DATA
OUTPUT CONFIGURATION: MAXIMUN ALLOWABLE OUTPUT VOLTAGE & LOAD:
SPST-NO 7 AMPS @ 260 OR 380 VAC
SPST-NO 4 AMPS @ 140 OR 280 VAC
OUTPUT DEVICE: MINIMUM LOAD:
TRIAC 50 MILLIAMPS
INSULATION CHARACTERISTICS
DIELECTRIC STRENGTH 2500 V rms NOT AVAILABLE 5 & 12 DC 4.3 & 10.3 VDC) 1.5 VDC 15 MILLIAMPS MAX 2500 V rms NOT AVAILABLE 5 & 12 VDCVDC 4.0 & 9.3 VDC 2.0 VDC 15 MILLIAMPS MAX. 2500 V rms NOT AVAILABLE 5 & 12 VDCVDC 4.0 & 9.3 VDC 2.0 VDC 16 MILLIAMPS MAX. 4000 V rms NOT AVAILABLE 3 TO 32 VDC 3 VDC 1 VDC 1500
INPUT DATA
AC - VOLTAGE: DC - VOLTAGE: MAXIMUM PULL-IN VOLTAGE: MINIMUM DROP-OUT VOLTAGE: INPUT IMPEDANCE:
GENERAL DATA
AMBIENT TEMPERATURE OPERATIONAL: STORAGE: RESPONSE TIME OPERATE MAX.: RELEASE MAX: INSULATION RESISTANCE: MOUNTING: - 40 C to + 65 C - 30 C to + 100 C 16 mS TURN ON 60 mS TURN OFF 1010 TO-3 H W L .780 X .670 X .990 - 30 C to + 80 C - 40 C to + 100 C 1/2 CYCLE - 30 C to + 80 C - 40 C to + 100 C 1/2 CYCLE - 30 C to + 80 C - 40 C to + 120 C 1/2 CYCLE
1010 P.C. H W L 0.25 X 0.5 X .875
1010 TO-3 H W L .700 X .860 X .860 H
1010 PANEL W L .78 X 1.75 X 2.25
C US
DIMENSIONS APPROVALS
SPECIFICATIONS PAGE:
PAGE 96 PAGE 94, 95 PAGE 102, 103 PAGE 101 PAGE104 PAGE NUMBER PAGE 97,98 PAGE 99, 100 WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957, DOCUMENT 100 PAGE 92
Magnecraft
Struthers-Dunn
SOLID STATE RELAYS & OPTO ISOLATORS
RELAY SERIES 6 (DSX)
DC Input - AC Output
6 (ASX)
AC Input - AC Output
6 (DDX)
DC Input - DC Output
301T
Opto-Isolators
NEW!
L.E.D.
L.E.D. INDICATES RELAY IS IN THE OPERATE MODE.
L.E.D. "ON" LAMP
L.E.D. "ON" LAMP
L.E.D. "ON" LAMP
DC CONTROLLED INPUT, DC OUTPUT AXIAL LEADS WITH SHRINK TUBE CASE
FEATURES
OPTIONAL SAFETY COVER FOR CLASS 6 AVAILABLE SEE PAGE 88
DC CONTROLLED INPUT, AC CONTROLLED INPUT, AC BACK TO BACK SCR AC BACK TO BACK SCR OUTPUT OUTPUT 2.5 TO 75 AMP LOADS PHOTO ISOLATED, ZERO VOLTAGE SWITCHING. 4000 V rms ISOLATION INPUT TO OUTPUT. INTERNAL RC (SNUBBER) NETWORK RFI SUPPRESSION. 2.5 TO 75 AMP LOADS PHOTO ISOLATED, ZERO VOLTAGE SWITCHING. 4000 V rms ISOLATION INPUTTO OUTPUT. INTERNAL RC (SNUBBER) NETWORK RFI SUPPRESSION.
12, 25 & 40 AMP LOADS AC & DC INPUTS AND OUTPUTS TRANSFORMER HIGH INPUT & OUTPUT ISOLATED, 2500 V rms ISOLATION ISOLATION INPUT TO OUTPUT. TURN ON 10K TURN OFF 100K. RFI SUPPRESSION. IDEAL FOR TRIGGERING SCR'S & TRIACS OR LOW VOLTAGE ON-OFF SWITCH. SPST-NO 12, 25 & 40 AMPS @ 0 TO 200 VDC SPST-NO 0.2 WATTS 250VAC/VDC
OUTPUT DATA
OUTPUT CONFIGURATION: MAXIMUN ALLOWABLE OUTPUT VOLTAGE & LOAD: SPST-NO 2.5 TO 75 AMPS @ 140 OR 280 VAC SPST-NO 2.5 TO 75 AMPS @ 140 OR 280 VAC
OUTPUT DEVICE: MINIMUM LOAD:
SCR 50 MILLIAMPS
SCR 50 MILLIAMPS
TRANSISTOR 20 MILLIAMPS
-
INSULATION CHARACTERISTICS
DIELECTRIC STRENGTH 4000 V rms NOT AVAILABLE 3 TO 32 VDC 3 VDC 1 VDC 1500
4000 V rms
2500 V rms
1000 V rms
INPUT DATA
AC - VOLTAGE: DC - VOLTAGE: MAXIMUM PULL-IN VOLTAGE: MINIMUM DROP-OUT VOLTAGE: INPUT IMPEDANCE: 90 TO 280 VAC 80 TO 140 VDC 90 VAC/80VDC 10 VAC/10VDC 60K NOT AVAILABLE 3.5 TO 32 VDC 3.5 VDC 1 VDC 1000 120 VAC 2.0 TO 120 VDC TO 10K 100k -
GENERAL DATA
AMBIENT TEMPERATURE OPERATIONAL: STORAGE: RESPONSE TIME OPERATE MAX.: RELEASE MAX: INSULATION RESISTANCE: MOUNTING: - 30 C to + 80 C - 40 C to + 120 C 1/2 CYCLE - 30 C to + 80 C - 40 C to + 120 C 10 mS 40 mS 1010 PANEL L H W L 0.78 X 1.75 X 2.25
C US
- 0 C to + 80 C - 40 C to + 120 C 100 uSec 1.0 mSec 1010 PANEL H W L
- 40 C to + 60 C
-
1010 PANEL H W 0.78 X 1.75 X 2.25
109 AXIAL LEADS/SOLDER H W L 0.45 X .438 X 1.4
DIMENSIONS APPROVALS PAGE NUMBER PAGE 93
0.78 X 1.75 X 2.25
C US
C
US
PAGE 105
PAGE 106
PAGE 107
PAGE 108
WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
APPLICATION DATA
CLASS
SSR
INTRODUCTION: SOLID STATE RELAY (SSR) is a relay with isolated input and output, whose functions are achieved by means of electronic components without the use of moving parts as found in Electromechanical relays. PRINCIPLE OF OPERATION: Solid State Relays are similar to Electromechanical relays, in that both use a control circuit and a separate circuit for switching the load. When voltage is applied to the input of the SSR, the relay is energized by a light emitting diode. The light from the diode is beamed into a light sensitive semiconductor which, in the case of zero voltage crossover relays, conditions the control circuit to turn on the output solid state switch at the next zero voltage crossover. In the case of nonzero voltage crossover relays, the output solid state switch is turned on at the precise voltage occurring at the time. Removal of the input power disables the control circuit and the solid state switch is turned off when the load current passes through the zero point of its cycle. APPLICATIONS: Solid State Relays are specially suitable in many applications. Listed below are some typical applications. Microprocessor-based Controls. Computers and Computer Peripherals. Process control Systems using PLCs Temperature Control Systems. Business Machines Medical Equipment Uninterrupted Power Supplies (UPS). Communication Traffic Signals, etc. APPLICATION AND SELECTION CRITERIA FOR SOLID STATE RELAYS: The Chart below indicates the areas in which SSR's (Solid State Relays) or EMR (Electromechanical Relays) has better capabilities. (X) Indicates the Better choice. SSR X X X X X X X X X X X X X X EMR X
LOAD CONSIDERATIONS (cont.) DC LOADS: All loads should be considered inductive and a Diode should be placed across the load to absorb any inductive surge on turnoff. RESISTIVE LOADS: Loads of constant value resistance are probably the simplest application of SSR's. Proper attention to the steady state current ratings and applied blocking voltage specifications normally will result in trouble-free operation. LAMP LOADS: Incandescent lamp loads, though basically resistive, present some special problems. Because the resistance of a cold tungsten filament is about five to ten percent of the heated value, a large inrush current can occur. The period of the inrush current can range from one half cycle to several cycles., depending on the thermal time constant of the filament. It is essential to verify that this inrush current is within the surge specifications of the SSR. Also check that the lamp rating of the SSR is not exceeded. This is a UL rating based on the inrush of a typical lamp. Because of the unusually low filament resistance at the time of turn-on, a zero voltage turn-on characteristic is particularly desirable with tungsten lamps.. It has been demonstrated that a zero voltage turn-on can extend the life of tungsten lamps by limiting inrush current. CAPACITIVE LOADS: Caution must be used with low impedance capacitive loads to verify that the di/dt capabilities are not exceeded. The di/dt of a discharged capacitive load with out external limiting impedance can approach infinity. Zero voltage turn-on is a particularly valuable means of limiting di/dt with capacitive loads.
Long Life Temperature Cycling Shock and Vibration Resistant Immunity to False Operation due to Transients Generation of RFI, EMI Multipole Multithrow (SPDT) Size (includes Heat Sink) for Equivalent Load Handling Contact Bounce Arcless Switching Acoustic Noise Zero Voltage Switching Ease Of Diagnosing Malfunction IC Compatibility Immunity to Humidity, Salt Spray & Dirt
LOAD CONSIDERATIONS A major portion of application problems with SSR's result from operating conditions which specific loads impose upon an SSR. The following types of loads point out the potential problems that can occur with SSR's.
MOTORS: Specifically, motors frequently have severe inrush currents during starting and can impose unusual voltages during turnoff. The inrush currents connected to mechanical loads having high starting torque or inertia should be carefully determined to verify that they are within the surge capabilities of the SSR. A current shunt and Oscilloscope should be used to examine the duration of the inrush current. Motor starting may frequently reoccur at short intervals and the affect of repetitive inrush currents on the thermal operating point of an SSR must be considered. Check the motor operating current and locked rotor current versus the SSR motor rating. The possibility of abnormally stalled rotor conditions which draw much higher than normal currents should be considered. An extended stalled rotor condition may require an oversized SSR or fuse protection. The generated EMF of certain motors can require an SSR to have a blocking voltage greater than might be expected from steady state line voltage. The voltage applied to an SSR by a motor circuit during turnoff should be examined with an oscilloscope to verify hat the applied voltages are safely below the specified SSR blocking voltages. Otherwise lock-on or erratic turnoff of the motor may occur. Some motor circuits may require higher than normal blocking voltage, transient limiting devices, or other techniques to control the voltage which must be blocked by an SSR during deceleration or direction reversal.
WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
PAGE 94
CLASS
SSR
TRANSFORMERS
APPLICATION DATA
PROTECTING THE OUTPUT SWITCH An SSR is a four layer semiconductor having 3 terminals: Cathode, Anode and Gate. Normally it blocks current in both the forward and reverse directions. The SCR is triggered on in the forward direction by a small gate current. The SCR remains on until load current decreases to a value less than necessary to maintain the SCR in the on state. When switching AC, two SSR's are connected in inverse parallel. A Triac also has 3 terminals, like the SCR, it normally blocks current in both directions; but may be triggered in either direction by a small gate current Both SCR's and Triacs are members of the thyristor family. Therefore, we use this term to denote both devices. There are 4 ways to put a thyristor into a conducting mode. Only one method is desirable and the other three are the source of most application problems. The 4 methods of Thyristor turn-on are A. Gate Turn-on: By injecting a controlled current into the gate (the desired method). B. Forward Breakover Turn-on: A voltage in excess of the Breakover (or Peak Blocking) voltage across Thyristor. C. DV/DT turn-on: A voltage which rises faster than the Thyristor can tolerate, and still remain in the off state. D. Thermal Turn-on: Allowing the temperature of the thyristor to go beyond the value sufficient to cause excessive leakage current, causing turn-on and possible thermal runaway. The last three methods can be protected against as follows. In those situations where high peak voltage transients occur, effective protection can be obtained by using metal oxide varistors (MOV). The MOV is a bidirectional voltage sensitive device that has low impedance when its design voltage threshold is exceeded. HEAT SINKING
In controlling transformers, the characteristics of the secondary load should be considered because it reflects the effective load on the SSR. Voltage transients from secondary load circuits, similarly, are frequently transformed and can be imposed on the SSR. Transformers present a special problem in that, depending on the state of the transformer flux at the time of turnoff, the transformer may saturate during the first half-cycle of subsequent applied voltage. This saturation can impose a very large current (Commonly ten to one hundred times rated primary current) on the SSR and exceed its half-cycle surge rating. SSR's having random turn-on may have a better chance of survival than a zero voltage turn-on device for they commonly require the transformer to support only a portion of the first half-cycle of the voltage. On the other hand, a random turn-on device will frequently close at the essentially zero voltage point (start of the half-cycle) and then the SSR must sustain the worst-case saturation current. A zero voltage turn-on device has the advantage that it turns on in a known, predictable mode and will normally immediately demonstrate (dependent on turnoff flux polarity) the worst-case condition. The use of an oscilloscope is recommended to verify that the half-cycle surge capability of the SSR is not exceeded. The severity of the transformer saturation problem varies greatly, dependent on the magnetic material of the transformer, saturated primary impedance, line impedance, etc. A safe rule of thumb in applying an SSR to a transformer primary is to select an SSR having a half-cycle current surge rating (RMS) greater than the maximum applied line voltage (RMS) divided by the transformer primary resistance. The primary resistance is usually easily measured and can be relied on as a minimum impedance limiting the first half-cycle of inrush current. The presence of some residual flux plus the saturated reactance of the primary will then further limit, in the worst case, the half-cycle surge safely within the surge rating of the SSR. SELECTING THE PROPER SSR NOMINAL LOAD CURRENT: Initially select a relay whose current rating exceeds the normal load current. Using the load current vs. temperature chart for that relay, check the actual current capacity at the ambient temperature to which the relay will be subjected. As an example, the chart below shows that a 25 ampere relay provided with a suitable heat sink can safely carry a maximum of 17 amperes continuously at 40C ambient. Since heat degrades the output semiconductor every effort should be made to keep the operating temperature of the SSR as low as possible
It is important to select the right size heat sink for your applications. SSR's will typically generate 1.2 watts per amp of load current. The maximum junction temperature of the output device is 115C. The total wattage is divided by the thermal resistance to get the temperature difference between the output device junction and the ambient temperature. For example a 25 Amp SSR with a 20 Amp load applied dissipates 24 watts when mounted on a aluminum plate 6" X 6" X 1/8" with thermal grease applied between the SSR base and aluminum plate. This combination produces a output junction temperature rise of 24 watts. 24W times (1 c/w relay + 1 c/w (heat sink) = a operating temperature of 48C. FUSING THE SSR has a I2T rating which is a measure of the amount of energy it can safely handle without damage. The I2T rating of the fuse is a measure of the amount of energy the fuse will pass to the SSR. To protect the SSR, the I2T of the Fuse should be less than that of the SSR. An SSR exposed to a surge greater than its nonrepetitive rating will normally fail as a shorted unit. EXPRESSIONS USED IN SPECIFICATIONS dv dt equals the maximum permissable rate of change of voltage in volts/microseconds Line Voltage Load Current Load Power Factor Line Frequency Inductance in Henrys Capacitance in microfarads Resistance in Ohms
25 Amp Styles 40 Load Current (Amps RMS) 35 30 25 20 15 10 5
6" x 6" x 1/8" Aluminum Plate Free Air Mounting Mounted on Heat Sink with 1c/w thermal resistance. (Sink to Ambient)
0 20 40 60 80 100 Max. Ambient Temperature (C)
V= I= (PF)= f= L= C= R 1 & R2 =
PAGE 95
WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
SPECIFICATIONS CLASS 226, 230, 231
TERMINALS PINS MATE WITH STANDARD PUSH-ON CONNECTORS. P.C. TERMINAL STYLE ALSO AVAILABLE. P.C. BOARD MOUNTABLE 1.5 AMP RATING
CLASS
SSR
FLANGED HEAT SINK STYLE WITH 3/16" SPADE STYLE TERMINALS FOR SOLDER OR Q.C. CONNECTORS
230E
226
P.C. BOARD MOUNTABLE WITH HEAT SINK 3.0AMP RATING
231
230T
MOUNTABLE ON STANDARD TO-3 TRANSISTOR HEAT SINK MOUNTABLE ON STANDARD TO-3 TRANSISTOR HEAT SINK
R
UL Recognized File No. E52197
CLASS 230/231 Maximum Average On-State Power Dissipation (Watts) 14 12 10 8 6 4 2 0 1 2 3 4 5 6 RMS On-State Current (AMPERES) 0
TYPICAL DERATING CURVES
CLASS 230E, 230T, 231D
4.0 3.0 Amp (230T) 6.7 c/w HEAT SINK
AMPERES
3.0 2.0 1.0 NO HEAT SINK 0 25 40 55 70 80 1.5 Amp (230E)
OPERATING TEMPERATURE (C)
CLASS 226 CURRENT RATINGS OUTPUT CURRENT RATINGS VS AMBIENT TEMPERATURE
7 Wakefield #401A 2C/Watt
CLASS 230/231 RMS ON STATE CURRENT (AMPERES)
PEAK SURGE CURRENT (NON-REPETITIVE) RMS AMPERES
SURGE CURRENT RATINGS
400 100 40
1.5 Amp series should not be operated above 1.5 Amps at duty cycle greater than 25%
CURRENT AMPS (AC)
6 5 Thermolloy 4 #6103 Base 14C/Watt 3 Integral 2 Heat sink 1 0 Wakefield #6908 6.7C/Watt
100 80 60
@25C 60 Hz
40
10 4 1 0.4
TJ = 105C
20
Thermal Joint compound used. 20 30 40 50
10 010 .10 1.0 10
60
70
AMBIENT TEMPERATURE (C)
SURGE CURRENT DURATION (SECONDS)
0.1 0 1 2 3 Maximum RMS On-State Voltage
WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
PAGE 96
CLASS
226
MINIATURE SOLID STATE RELAY
CLASS 226
UP TO 7 AMPS SPST--NO DC INPUTS AC OUTPUTS
1.50 (38.5)
RANDOM VOLTAGE TURN ON
COMPATIBLE WITH TTL GATES. PRINTED CIRCUIT AND PUSH-ON TERMINAL PIN VERSIONS.
UL Recognized File No. E52197
R
Dimensions shown in Inch and (Millimeters).
1.18 (30.2) .200 (5.1) .300 (7.5)
.155 (3.9)
.990 Typ. (25.1)
.670 (17.0)
INPUT
OUTPUT
.755 (19.1) .600 Max (15.2)
FIG. "A"
.050 (38.1)
.4.92 (12.5)
.4.92 (12.5)
.156 Dia. (3.8) 2 Places .340 (8.6) .940 (23.4) .600 Max (15.2) .062 Dia. (1.6) Typ. all Pins
Series 226 Schematic typical TTL input Connections TOP VIEW + 5V Supply 226R
Standard TTL Gate + 5V Supply Load Input 5 VDC 15 mA
R1
MAX. RNS LOAD CURRENT (AMPS)
FIG. "B"
.050 (1.3)
Output 120 or 240 VAC up to 7 Amps
THERMAL DERATING CURVE
8 6 4 2 0 10
Y
Z 20 30 40 50 60 70 80
AMBIENT TEMPERATURE (C)
Y= WITHOUT EXTERNAL HEAT SINK. Z= WITH HEAT SINK HAVING 0 SA= 3.2C/W.
INPUT CHARACTERISTICS Input Impedance Response Time Maximum Rate of Rise of Off State Voltage dv/dt OUTPUT CHARACTERISTICS Rated Load Current (Amps rms) Input Current (Typ.) 5VDC Maximum off State Leakage current ID (RMS) Non-Repetitive Surge Current one Cycle (Amps peak) Maximum rms Overload current for 1 second Max I2T For Fusing ( t= 8-3ms) A2 sec Thermal Resistance Junction To Case (TJ , Max.= 1150C) 0c/w
5 or 12 VDC 5V= 240 Ohms / 12V=820 Ohms Typ. Turn-on 10 mS max., Turn-off 60 mS max. 100V/uSec blocking 4V/uSec commutating 120 VAC or 240 VAC 7 Amperes 10 Ma 0.1 mA @ 25C 100 Amperes 18 Amperes 24 Amperes 3.4c/w
PAGE 97
WEBSITE: www.magnecraft.com - EMAIL:info@magnecraft.com - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
CLASS
MINIATURE SOLID STATE RELAY
226
SPECIFICATIONS CLASS 226
INPUT CHARACTERISTICS Reverse Polarity Protected: Input Filtered for transients less than one millisecond.: OUTPUT CHARACTERISTICS Rated Load Current: IT (RMS): Line Voltage Range (VAC): Maximum output voltage (VAC): Non-Repetitive Peak Voltage VDSM (Blocking Voltage): Minimum Load Current IT MIN (RMS) to maintain "On": Maximum Off State Leakage current ID (RMS): Maximum RMS On-State Voltage VT (RMS) Maximum Voltage drop across relay output @ rated current: Minimum off-state dv/dt: MISCELLANEOUS Contact configuration: Dielectric Strength VISO (Input-Output Isolation): Insulation Resistance RISO @ 500VDC: Operating temperature Range: Storage temperature Range: Life: Mounting: Weight:
NO NO 7 Amps W226R & RE-7 Models: 120 VAC, W226R & RE-8 Models: 240 VAC W226R & RE-7 Models: 260 VAC, W226R & RE-8 Models: 380 VAC W226R & RE-7 Models: 400 VAC, W226R & RE-8 Models: 700 VAC 50 mA 0.1 mA @ 25C, 1.0 mA @ 65C W226R & RE-7 Models: 1.8V, W226R & RE-8 Models: 3.6 V 100V/uSec blocking 4V/uSec commutating SPST-NO 2500 VAC 1010 -30C to +80C -40C to +100C Greater than 100 million operations TO-3 0.45 oz. (13 g)
PUSH-0N TERMINAL RECEPTACLES MOLEX FOR 18-22 AWG 02-06-1103 FOR 24-30 02-06-1132 WINCHESTER 156-10185 156-10245
INPUT (Over Operating Temperature Range) 0UTPUT (Over Operating Temperature Range) PART NUMBERS FIGURE INPUT VOLTAGE MIN. MAX. PULL-IN DROPOUT VOLTAGE VOLTAGE NOMINAL VOLTAGE MAX. VOLTAGE OUTPUT CURRENT
PUSH ON TERMINALS
W226R-7-5A1 W226R-7-12A1 W226R-8-5A1 W226R-8-12A1 W226RE-7-5A1 W226RE-7-12A1 W226RE-8-5A1 W226RE-8-12A1 A A A A B B B B 5 VDC 12 VDC 5 VDC 12 VDC 5 VDC 12 VDC 5 VDC 12 VDC 4.3 VDC 10.3 VDC 4.3 VDC 10.3 VDC 4.3 VDC 10.3 VDC 4.3 VDC 10.3 VDC 1.4 VDC 2.5 VDC 1.4 VDC 2.5 VDC 1.4 VDC 2.5 VDC 1.4 VDC 2.5 VDC 120 VAC 120 VAC 240 VAC 240 VAC 120 VAC 120 VAC 240 VAC 240 VAC 260 VAC 260 VAC 380 VAC 380 VAC 260 VAC 260 VAC 380 VAC 380 VAC 7 AMPS 7 AMPS 7 AMPS 7 AMPS 7AMPS 7AMPS 7 AMPS 7AMPS
PRINTED CIRCUIT TERMINALS
All current ratings are based on use of suitable thermally conductive compound (e.g. silicone grease between the SSR mounting base and mounting surface of suitable heat sink). Part Numbers shown also available thru Stocking Distribution.
WEBSITE: www.magnecraft.com - EMAIL:info@magnecraft.com - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
PAGE 98
CLASS
230
MINIATURE P.C. SOLID STATE RELAY
CLASS 230
1.5 & 3 AMP SWITCHING SPST--NO DC INPUTS, AC OUTPUTS ZERO VOLTAGE SWITCHING.
CLASS 230 E 1.5 AMP RATED
Dimensions Shown in Inches & (Millimeter) 0.296 0.875 (7.5) (22.3) 0.50 (12.7)
230E
0.6 (15.2) 10 Bottom 8 -1 0.7 (17.7) +16 0.30 0.50 (7.62) (12.7) 0.20 (5.1) .020 (.50) 0.30 (7.6)
CLASS 230T 4.0 AMP RATED
FIGURE A
.030 (.76) 0.335 (8.5)
230T
1.23 (31.4) 10 +16 DC AC Input Output 8 Bottom -1 .200 (5.1) .400 (10.1) 0.150 Dia. (3.8) Terminals .025, (6.3) Typical
FIGURE B
UL Recognized File No. E52197
R
PIN 16 = + DC INPUT PIN 1 = DC INPUT PIN 8 = AC LOAD OUTPUT PIN 10 = AC LOAD OUTPUT
INPUT CHARACTERISTICS Input Impedance (Current @ Nominal Voltage) Response Time Maximum Rate of Rise of Off State Voltage dv/dt OUTPUT CHARACTERISTICS Rated Load Current (Amps rms) Maxium off State Leakage current ID (RMS) Non-Repetitive Surge Current one Cycle (Amps peak) Maximum rms Overload current for 1 second Max I2T For Fusing ( t= 8-3ms) A2 sec Thermal Resistance Junction To Case (TJ , Max.= 1150C) 0c/w
5 or 12 VDC 13mA typical / 16 mA max. 1/2 Cycle 200V/uSec blocking 4V/uSec commutating 120 VAC or 240 VAC 230E 1.5 Amps, 230T 3.0 Amps 1 mA max. 20 Amperes 5 Amperes 4.5 Amperes 230T 8c/w
PAGE 99
WEBSITE: www.magnecraft.com - EMAIL:info@magnecraft.com - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
CLASS
MINIATURE P.C. SOLID STATE RELAY
230
SPECIFICATIONS CLASS 230
INPUT CHARACTERISTICS Reverse Polarity Protected: Input Filtered for transients less than one millisecond.: OUTPUT CHARACTERISTICS Rated Load Current: IT (RMS): Line Voltage Range (VAC): Maximum output voltage (VAC): Non-Repetitive Peak Voltage VDSM (Blocking Voltage): Minimum Load Current IT MIN (RMS) to maintain "On": Maximum Off State Leakage current ID (RMS): Maximum RMS On-State Voltage VT (RMS) @ rated current: Maximum rate of rise off-state voltage dv/dt: MISCELLANEOUS Contact configuration: Dielectric Strength VISO (Input-Output Isolation): Insulation Resistance RISO @ 500VDC: Operating temperature Range: Storage temperature Range: Life: Mounting Weight:
NO NO W230E Models: 1.5 Amps, W230T Models: 3 Amps 120 VAC or 240 VAC 140 VAC or 280 VAC 120V Models: 400 VAC, 240V Models: 500 VAC 20 mA @ 25C 1.0 mA max. 1.7 V 200V/uSec SPST-NO 2500 VAC 1010 -30C to +80C -40C to +100C Greater than 100 million operations P.C. 0.37 oz. (10.6 g)
PUSH-0N TERMINAL RECEPTACLES MOLEX FOR 18-22 AWG 02-06-1103 FOR 24-30 02-06-1132 WINCHESTER 156-10185 156-10245
INPUT (Over Operating Temperature Range) 0UTPUT (Over Operating Temperature Range) CROSS REFERENCE PART NUMBERS FIGURE INPUT VOLTAGE MIN. MAX. PULL-IN DROPOUT VOLTAGE VOLTAGE NOMINAL VOLTAGE MAX. VOLTAGE OUTPUT CURRENT CP CLARE/ THETA-J
PRINTED CIRCUIT TERMINALS
W230E-1-5 W230E-2-5 W230E-1-12 W230E-2-12 W230T-3-5 W230T-4-5 W230T-3-12 W230T-4-12 A A A A B B B B 5 VDC 5 VDC 12 VDC 12 VDC 5 VDC 5 VDC 12 VDC 12 VDC 4.0 VDC 4.0 VDC 9.3 VDC 9.3 VDC 4.0 VDC 4.0 VDC 9.3 VDC 9.3 VDC 2.0 VDC 2.0 VDC 2.0 VDC 2.0 VDC 2.0 VDC 2.0 VDC 2.0 VDC 2.0 VDC 120 VAC 240 VAC 120 VAC 240 VAC 120 VAC 240 VAC 120 VAC 240 VAC 140 VAC 280 VAC 140 VAC 280 VAC 140 VAC 280 VAC 140 VAC 280VAC 1.5 AMPS 1.5 AMPS 1.5 AMPS 1.5 AMPS 3 AMPS 3 AMPS 3 AMPS 3 AMPS 0FA1202 0FA2402 0FB1202 0FB2402 0FA1205D 0FA2405D 0FB1205D 0FB2405D
PRINTED CIRCUIT TERMINALS WITH HEAT SINK
All current ratings are based on use of suitable thermally conductive compound (e.g. silicone grease between the SSR mounting base and mounting surface of suitable heat sink). Part Numbers shown also available thru Stocking Distribution.
WEBSITE: www.magnecraft.com - EMAIL:info@magnecraft.com - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
PAGE 100
CLASS
231
MINIATURE SOLID STATE RELAY
CLASS 231
4 AMPS SPST--NO DC INPUTS, AC OUTPUTS ZERO VOLTAGE SWITCHING.
.340 Max (8.6)
,048 Max (1.2)
.600 Max (15.24)
1.40 (35.5) 1.19 (30.2) 1 AC LOAD .860 (21.8)
+3
INPUT .078 R (1.98) .250 (6.3) .250 x .032 Typ. (6.3) x .81 .187 x .032 Typ. (4.7) x .81
Top View
2 AC .595 (15.1) .860 (21.8)
-4
Dimensions Shown in Inches & (Millimeters)
UL Recognized File No. E52197
INPUT CHARACTERISTICS Input Impedance (Current @ Nominal Voltage) Response Time Maximum Rate of Rise of Off State Voltage dv/dt OUTPUT CHARACTERISTICS Rated Load Current (Amps rms) Maximum off State Leakage current ID (RMS) Non-Repetitive Surge Current one Cycle (Amps peak) Maximum rms Overload current for 1 second Max I2T For Fusing ( t= 8-3ms) A2 sec Thermal Resistance Junction To Case (TJ , Max.= 1150C) 0c/w
5 or 12 VDC 13mA typical / 16 mA max. 1/2 Cycle 200V/uSec blocking 10V/uSec commutating 120 VAC or 240 VAC 4 Amperes 1 mA @ 25C 20 Amperes 5 Amperes 4.5 Amperes 6c/w
THE W231 SSR HAS THE SAME ELECTRICAL SPECIFICATIONS AS LISTED FOR THE W230 SSR's. THE EXCEPTION IS THE CLASS W231 IS RATED AT 4.0 AMPS.
QUICK DISCONNECT TERMINALS WITH .060 DIA. HOLES TERMINALS 1 & 2, .250 X .032 BRASS TERMINALS 3 & 4, .187 X .032 BRASS INPUT (Over Operating Temperature Range) 0UTPUT (Over Operating Temperature Range) CROSS REFERENCE PART NUMBERS INPUT VOLTAGE MIN. MAX. PULL-IN DROPOUT VOLTAGE VOLTAGE NOMINAL VOLTAGE MAX. VOLTAGE OUTPUT CURRENT CP CLARE/ THETA-J
FLANGE MOUNT
W231D-3-5 W231D-4-5 W231D-3-12 W231D-4-12 5 VDC 5 VDC 12 VDC 12 VDC 4.0 VDC 4.0 VDC 9.3 VDC 9.3 VDC 2.0 VDC 2.0 VDC 2.0 VDC 2.0 VDC 120 VAC 240 VAC 120 VAC 240 VAC 140 VAC 280 VAC 140 VAC 280 VAC 4 AMPS 4 AMPS 4 AMPS 4 AMPS 0FA1205 0FA2405 0FB1205 0FB2405
All current ratings are based on use of suitable thermally conductive compound (e.g. silicone grease between the SSR mounting base and mounting surface of suitable heat sink). Mounting: TO-3 Style. Weight: .57oz. (16.2 grams). Part Numbers shown also available thru Stocking Distribution.
PAGE 101
WEBSITE: www.magnecraft.com - EMAIL:info@magnecraft.com - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
SPECIFICATIONS SOLID STATE RELAY
HI DV GH RA /DT TI NG
CLASS
6
UT LS TP INA OU RM TE
NEW!
L.E.D. "ON" LAMP
Recognized to Canadian safety requirements under the Component Recognition Program of Underwriters Laboratories Inc. UL Recognized File No. E52197
UT S INP MINAL R TE
CL
AS
S6
OUTLINE DIMENSIONS
Dimensions shown in Inch and (Millimeter).
SS
R
0.19 0.37 (4.8) (9.4)
2.25 (57.2) 1.87 (47.5)
RU CO GG NS ED TR UC T
IO
N
0.32 (8.1)
1.00 1.75 (25.4) (44.5)
4 OUTPUT 3
INPUT
2
1.10 (27.9)
RED L.E.D.
1
1.75 (44.45)
.49 Typ. (12.5) .175 Dia. (4.44) (2 Holes)
Clamping Plate 4 Places (Not used on models .996 high)
INPUT
.215 (5.46)
OUTPUT SEE CHART
.265 max. (6.73)
INPUT & OUTPUT SCREW SIZE (Shown in Millimeters) UP TO 40 AMP INPUT 3.5 mm ABOVE 40 AMP 3.5 mm OUTPUT 4 mm 6 mm
.996 max. (25.3) for 25 & 40 amp DDX models & for 75 Amp DSX & ASX models. .800 max (20.32) for models ASX, DSX & DTX models up to 40 Amps & DDX 12 Amp models.
SURGE: OUTPUT 120 & 240 VAC CLASS 6 TYPICAL INPUT CURRENT 40 35 Input Current (mA) 30 25 20 15 10 5 0 10 20 30 100 200 300 Input Voltage (Volts) DC Input Models AC Input Models AC INPUT DC INPUT 1000 500 200 100 50 20 10 5 2 1 .01 .02 .05 0.1 0.2 0.5 1.0 2.0 5.0 10.0 Time in Seconds
Surge: Curves represent relay tolerance to load surge currents as to magnitude and duration of both repetitive and non-repetitive surge currents.
2.5 Amps 75 Amps 40 Amps 25 Amps 10 Amps
Non- Repetitive Surge RMS Amps
WEBSITE: www.magnecraft.com - EMAIL:info@magnecraft.com - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
PAGE 102
CLASS
6
GENERAL SPECIFICATIONS
SPECIFICATIONS CLASS 6 SOLID STATE RELAYS
INPUT CHARACTERISTICS Input voltage range: Power indicator: Reverse Polarity Protected: Input Filtered for transients less than one millisecond.: Control current: OUTPUT CHARACTERISTICS Contact rating: Line Voltage Range (VAC) Maximum output voltage (VAC): Non-Repetitive Peak Voltage VDSM (Blocking Voltage) Minimum Load Current IT MIN (RMS) to maintain "On" Maximum Off State Leakage current ID (RMS) Maximum RMS On-State Voltage VT (RMS) Maximum Voltage drop across relay output @ rated current: Minimum off-state dv/dt: MISCELLANEOUS CHARACTERISTICS Contact configuration: Dielectric Strength VISO (Input-Output Isolation) Insulation Resistance RISO @ 500VDC Operating temperature Range Storage temperature Range Life: Weight
3-32 VDC, 90-280 VAC or 0 to 200VDC L.E.D. Lamp YES: DC Input with AC output styles only. No 12 mA @ 5Vdc, 10 mA @ 120 Vac 2 Amps to 75 Amps W61 Models: 24-120VAC, W62 Models: 40-240 VAC W61: 140VAC, W62: 280 VAC W61: 300VAC , W62: 600VAC Up to 40 amp Models: 50 ma, 50 to 75 Amp models: 250mA Up to 40 amp Models: 8 mA, 50 to 75 Amp models: 10mA Up to 40 amp Models: 1.6V, 50 to 75 Amp models: 1.8 V 500v/usec SPST-NO (1 FORM A) 4000 VAC, DDX models 2500 VAC 1010 -40C to +80C -40C to +100C Greater than 100 million operations 2.5 to 50 AMP Models: 4 oz. (110 g) 75 AMP Models: 6.8 oz. (192 g) 25 AMP & 40 AMP, DDX Models: 4.76 oz. (135 g)
Thermal Derating Curve & Load Characteristics
2.5 Amp Style Load Current (Amps RMS) Load Current (Amps RMS)
6" x 6" x 1/8" Aluminum Plate
16 14 12 10 8 6 4 2
10 Amp Styles Load Current (Amps RMS)
6" x 6" x 1/8" Aluminum Plate Heat Sink with 1c/w thermal resistance.
40 35 30 25 20 15 10 5
25 Amp Styles
Mounted on Heat Sink with 1c/w thermal resistance. (Sink to Ambient)
3
2
1 0
Free Air Mounting
Free Air Mounting
6" x 6" x 1/8" Aluminum Plate Free Air Mounting
20 40 60 80 100 Max. Ambient Temperature (C)
0 20 40 60 80 100 Max. Ambient Temperature (C) 75 Amp Styles 75
0 20 40 60 80 100 Max. Ambient Temperature (C)
90 Load Current (Amps RMS) 80 70 50 40 30 20 10 0 20 40 60 80 100 Max. Ambient Temperature (C)
Free Air Mounting 6" x 6" x 1/8" Aluminum Plate
-90 Load Current (Amps RMS)
Mounted on Heat Sink with 1c/w thermal resistance.
60
6" x 6" x 1/8" Aluminum Plate
-95 -100 -105 -110
45 40 30 20 10 0
0 10 20 30 40 50 60 70 80 Max. Ambient Temperature (C)
All current ratings in the following pages are based on use of suitable thermally conductive compound (e.g. silicone grease between the SSR mounting base and mounting surface of suitable heat sink).
PAGE 103
WEBSITE: www.magnecraft.com - EMAIL:info@magnecraft.com - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
Max. Allowable Case temperature (c)
40 & 50 Amp Styles
DC CONTROLLED INPUT TRIAC OUTPUT SSR
High Transient Capability--Single output features back to back SCR's and internally mounted RC (snubber) network for high dv/dt applications. Photo-Isolated, Zero Voltage Switching-- Optically coupled for 4000 VAC isolation between input and output and RFI suppression.
CLASS
6
CLASS 6
DC CONTROLLED INPUT WITH L.E.D. "ON" LAMP. AC TRIAC OUTPUT.
NEW!
L.E.D. "ON" LAMP
UL Recognized File No. E52197
Recognized to Canadian safety requirements under the Component Recognition Program of Underwriters Laboratories Inc.
INPUT CHARACTERISTICS Input Impedance Response Time Maximum Rate of Rise of Off State Voltage dv/dt OUTPUT CHARACTERISTICS Rated Load Current (Amps rms) U/L Incandescent Lamp Ampere Ratings U/L Motor Load Ampere Ratings Non-Repetitive Surge Current one Cycle (Amps peak) Maximum rms Overload current for 1 second Max I2T For Fusing ( t= 8-3ms) A2 sec Thermal Resistance Junction To Case (TJ , Max.= 1150C) 0c/w
SEE CLASS 6 GENERAL SPECIFICATIONS
3 to 32 VDC
1500 ohms minimum 1/2 Cycle Max. 200 Volts per microsecond
120 or 240 VAC
10.0 7.0 4.5 100 24 42 2.1
PART NUMBERS
MIN. CONTROL MAX. VOLTAGE PULL-IN DROPOUT RANGE VOLTAGE VOLTAGE
INPUT (Over Operating Temperature Range) 0UTPUT (Over Operating Temperature Range) CROSS REFERENCE TO: NOMINAL MAX. MAX. POTTER & VOLTAGE VOLTAGE CURRENT CRYDOM IDEC BRUMFIELD RANGE RATING
W6110DTX-1 3-32 VDC 3 VDC W6210DTX-1 3-32 VDC 3 VDC
1 VDC 1 VDC
24-120AC 140 VAC 48-240AC 280 VAC
10 AMPS 10 AMPS
TD1210 TD2410
-
SSRT120D10 SSRT240D10
All current ratings are based on use of suitable thermally conductive compound (e.g. silicone grease between the SSR mounting base and mounting surface of suitable heat sink). Part Numbers shown also available thru stocking distribution.
WEBSITE: www.magnecraft.com - EMAIL:info@magnecraft.com - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
PAGE 104
CLASS
6
DC CONTROLLED SOLID STATE RELAY
CLASS 6
DC CONTROLLED INPUT WITH L.E.D. "ON" LAMP. AC SCR OUTPUTS UP TO 75 AMPS.
High Transient Capability--Single output features back to back SCR's an internal mounted RC (snubber) network for high dv/dt applications. Photo-Isolated, Zero Voltage Switching-- Optically coupled for 4000 VAC isolation between input, output and RFI suppression.
NEW!
L.E.D. "ON" LAMP
UL Recognized File No. E52197
Recognized to Canadian safety requirements under the Component Recognition Program of Underwriters Laboratories Inc.
INPUT CHARACTERISTICS Input Impedance Response Time Maximum Rate of Rise of Off State Voltage dv/dt OUTPUT CHARACTERISTICS Rated Load Current (Amps rms) U/L Incandescent Lamp Ampere Ratings U/L Motor Load Ampere Ratings Non-Repetitive Surge Current one Cycle (Amps peak) Maximum rms Overload current for 1 second Max I2T For Fusing ( t= 8-3ms) A2 sec Thermal Resistance Junction To Case (TJ , Max.= 1150C) 0c/w Minimum Load current, (mA).
SEE CLASS 6 GENERAL SPECIFICATIONS
3 to 32 VDC 400 ohms @ 3 VDC Typical 1/2 Cycle Max. 500 Volts per microsecond 120 VAC or 240 VAC 2.5 2.0 1.0 100 5 72 8.5 50 10 8.0 4.5 100 24 72 1.78 50 25 16 8 250 40 800 1.02 120 40 30 14 350 80 1250 0.63 250 50 30 14 350 100 1250 0.63 250 75 39 25 1150 150 5000 0.63 250
200
INPUT (Over Operating Temperature Range) 0UTPUT (Over Operating Temperature Range) PART NUMBERS MIN. CONTROL MAX. VOLTAGE PULL-IN DROPOUT RANGE VOLTAGE VOLTAGE NOMINAL VOLTAGE RANGE MAX. VOLTAGE NAX. CURRENT RATING
CROSS REFERENCE TO: CRYDOM IDEC POTTER & BRUMFIELD
W6102DSX-1 W6110DSX-1 W6125DSX-1 W6140DSX-1 W6150DSX-1 W6175DSX-1 W6202DSX-1 W6210DSX-1 W6225DSX-1 W6240DSX-1 W6250DSX-1 W6275DSX-1
3-32 VDC 3-32 VDC 3-32 VDC 3-32 VDC 3-32 VDC 3-32 VDC 3-32 VDC 3-32 VDC 3-32 VDC 3-32 VDC 3-32 VDC 3-32 VDC
3 VDC 3 VDC 3 VDC 3 VDC 3 VDC 3 VDC 3 VDC 3 VDC 3 VDC 3 VDC 3 VDC 3 VDC
1 VDC 1 VDC 1 VDC 1 VDC 1 VDC 1 VDC 1 VDC 1 VDC 1 VDC 1 VDC 1 VDC 1 VDC
24-120AC 24-120AC 24-120AC 24-120AC 24-120AC 24-120AC 48-240AC 48-240AC 48-240AC 48-240AC 48-240AC 48-240AC
140 VAC 140 VAC 140 VAC 140 VAC 140VAC 140VAC 280 VAC 280 VAC 280 VAC 280 VAC 280 VAC 280 VAC
2.5 AMPS 10 AMPS 25 AMPS 40 AMPS 50 AMPS 75 AMPS 2.5 AMPS 10 AMPS 25 AMPS 40 AMPS 50 AMPS 75 AMPS
D1202 D1210 D1225 D1240
EOM1DA22-4-32 RSSD-10A EOM1DA42-4-32 RSSD-25A SSR240D25 RSSD-40A RSSD-50A SSR240D50 RSSD-75A SSR240D80 RSSD-10A EOM1DA44-4-32 RSSD-25A SSR240D25 RSSD-40A RSSD-50A SSR240D50 RSSD-75A SSR240D80
D2402 D2410 D2425 D2440 D2450 D2475
All current ratings are based on use of suitable thermally conductive compound (e.g. silicone grease between the SSR mounting base and mounting surface of suitable heat sink). Part Numbers shown also available thru stocking distribution.
PAGE 105
WEBSITE: www.magnecraft.com - EMAIL:info@magnecraft.com - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
AC CONTROLLED SOLID STATE RELAY
High Transient Capability--Single output features back to back SCR's and internally mounted RC (snubber) network for high dv/dt applications. Photo-Isolated, Zero Voltage Switching-- Optically coupled for 4000 VAC isolation between input and output and RFI suppression.
CLASS
6
CLASS 6
AC CONTROLLED INPUT WITH L.E.D. "ON LAMP" AC SCR OUTPUT.
NEW!
L.E.D. "ON" LAMP
UL Recognized File No. E52197
Recognized to Canadian safety requirements under the Component Recognition Program of Underwriters Laboratories Inc.
INPUT CHARACTERISTICS Input Impedance Response Time Maximum Rate of Rise of Off State Voltage dv/dt OUTPUT CHARACTERISTICS Rated Load Current (Amps rms) U/L Incandescent Lamp Ampere Ratings U/L Motor Load Ampere Ratings Non-Repetitive Surge Current one Cycle surge (Amps peak) Maximum rms Overload current for 1 second Max I2T For Fusing ( t= 8-3ms) A2 sec Thermal Resistance Junction To Case (TJ , Max.= 1150C) 0c/w Minimum Load current, (mA):
SEE CLASS 6 GENERAL SPECIFICATIONS
90 to 280 VAC or 80 to 140 VDC 13K ohms @ 120VAC typical 10 mS Turn ON, 40 mS Turn OFF. 200 500 Volts per microsecond
120 VAC or 240 VAC
2.5 2.0 1.0 100 5 72 8.5 50
10 8.0 4.5 100 24 72 1.48 50
25 16 8.0 250 40 800 1.02 120
40 50 30 30 14 14 350 350 80 100 1250 1250 0.63 0.63 120 120
75 39 25 1150 150 5000 0.63 120
INPUT (Over Operating Temperature Range) PART NUMBERS CONTROL VOLTAGE RANGE MAX. PULL-IN VOLTAGE MIN. DROPOUT VOLTAGE
0UTPUT (Over Operating Temperature Range)
CROSS REFERENCE TO: IDEC POTTER & BRUMFIELD
NOMINAL MAX. MAX. VOLTAGE VOLTAGE CURRENT CRYDOM RANGE RATING
W6110ASX-1 W6125ASX-1 W6140ASX-1 W6150ASX-1 W6175ASX-1 W6202ASX-1 W6210ASX-1 W6225ASX-1 W6240ASX-1 W6250ASX-1 W6275ASX-1
90 -280 VAC 90 -280 VAC 90 -280 VAC 90 -280 VAC 90 -280 VAC 90 -280 VAC 90 -280 VAC 90 -280 VAC 90 -280 VAC 90 -280 VAC 90 -280 VAC
90 VAC 90 VAC 90 VAC 90 VAC 90 VAC 90 VAC 90 VAC 90 VAC 90 VAC 90 VAC 90 VAC
10 VAC 10 VAC 10 VAC 10 VAC 10 VAC 10 VAC 10 VAC 10 VAC 10 VAC 10 VAC 10 VAC
24-120AC 24-120AC 24-120AC 24-120AC 24-120AC 48-240AC 48-240AC 48-240AC 48-240AC 48-240AC 48-240AC
140 VAC 140 VAC 140 VAC 140 VAC 140VAC
10 AMPS 25 AMPS 40 AMPS 50 AMPS 75 AMPS
A1210 A1225 A1240 A1250 A1275 A2402 A2410 A2425 A2440 A2450 A2475
RSSAN-10A RSSAN-25A RSSAN-40A RSSAN-50A RSSAN-75A RSSAN-10A RSSAN-25A RSSAN-40A RSSAN-50A RSSAN-75A
SSR240A25 SSR240A50 SSR240A80 SSR240A25 SSR240A50 SSR240A80
280 VAC 2.5 AMPS 280 VAC 10 AMPS 280 VAC 25 AMPS 280 VAC 40 AMPS 280 VAC 50 AMPS 280 VAC 75 AMPS
Part Numbers shown also available thru stocking distribution. All current ratings are based on use of suitable thermally conductive compound (e.g. silicone grease between the SSR mounting base and mounting surface of suitable heat sink).
WEBSITE: www.magnecraft.com - EMAIL:info@magnecraft.com - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
PAGE 106
CLASS
6
DC CONTROLLED INPUT DC OUTPUT
CLASS 6
DC CONTROLLED INPUT DC OUTPUT
Transformer-Isolated, for 2500 VAC isolation between input and output and RFI suppression.
NEW!
L.E.D. "ON" LAMP
UL Recognized File No. E52197
Recognized to Canadian safety requirements under the Component Recognition Program of Underwriters Laboratories Inc.
INPUT CHARACTERISTICS Input Impedance Response Time Maximum Rate of Rise of Off State Voltage dv/dt OUTPUT CHARACTERISTICS Rated Load Current (Amps rms) Minimum Load current to maintain "On" Non-Repetitive Surge Current (1 cycle surge) FW rectified current repetitive 60 Hz Amps peak Voltage drop across output @ rated current Max I2T For Fusing ( t= 8-3ms) A2 sec Thermal Resistance Junction To Case 0c/w Max. off state leakage current:
SEE COMPLETE SPECIFICATIONS PAGES 83 & 84
3.5 to 32 VDC 1000 ohms minimum 100 uS: On, 1.0 mS: Off 600 uS: On, 2.6 mS Off 200 Volts per microsecond 0 12.0 20 mA 27 17 2.83 2.1 1.06 12 mA to 200 VDC 25 20 mA 50 2.83 2.1 1.06 12 mA 40 20 mA 90 2.83 2.1 1.06 12 mA
PART NUMBERS
CONTROL VOLTAGE RANGE
INPUT (Over Operating Temperature Range) 0UTPUT (Over Operating Temperature Range) MAX. MIN. NOMINAL MAX. PULL-IN DROPOUT VOLTAGE CURRENT VOLTAGE VOLTAGE RANGE RATING
CROSS REFERENCE CRYDOM
W6212DDX-1 W6225DDX-1 W6240DDX-1
3.5 - 32 VDC 3.5 VDC 3.5 - 32 VDC 3.5 VDC 3.5 - 32 VDC 3.5 VDC
1 VDC 1 VDC 1 VDC
0 -200 VDC 0 -200 VDC 0 -200 VDC
12 AMPS 25 AMPS 40 AMPS
D2D12 D1D20* D1D40*
Part Numbers shown also available thru stocking distribution. All current ratings are based on use of suitable thermally conductive compound (e.g. silicone grease between the SSR mounting base and mounting surface of suitable heat sink). * Crydom relays only rated at 0 - 100 VDC.
PAGE 107
WEBSITE: www.magnecraft.com - EMAIL:info@magnecraft.com - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
301T OPTO-ISOLATOR
OPTICAL COUPLING PROVIDES HIGH INPUT TO OUTPUT ISOLATION. CAN BE USED AS AN ON/OFF SWITCH OR LOW VOLTAGE CONTROLLED RESISTOR. IDEAL FOR TRIGGERING SCR'S AND TRIACS.
CLASS
SSR
301T OPTO-ISOLATOR 0.2 WATT OUTPUT VAC OR VDC OUTPUTS
SPECIFICATIONS 301T
CONTACTS Output Voltage Max:. INSULATION RESISTANCE Dielectric Strength Across Open Contacts: Insulation Resistance: 250 VDC or VAC Peak 1.00 .125 (25.4 3.17)
OUTLINE DIMENSIONS
L 1.40 Max. (35.6)
Shrink Tube Case
PC
.438 (11.1) 1.00 .125 (25.4 3.17)
1000 V rms Between all insulated Points 9 10Ohms
ENVIRONMENTAL CAPABILITIES Ambient Temperature Operating: -40C to + 60C Miscellaneous Weight: 0.04 oz (1.1 g)
# 26 AWG Typical
.45 Max (11.4)
SCHEMATIC
+ If DC
NOT RECOMENDED FOR WAVE OR DIP SOLDERING. ALSO MAY BE AFFECTED BY CLEANING SOLVENTS
L
Lamp
PC
R
UL Recognized File No. E104675
INPUT PART NUMBERS W301T1-2A1 W301T1-2B1 W301T1-12B1 W301T1-120A1 LAMP TYPE VOLTAGE
OUTPUT CURRENT ON (mA) RESISTANCE (Ohms max.) 40 25 24 1.3 2000 1000 400 1200 POWER DISSIPATION Per pole (mW) 200 200 200 200
RESPONSE TIME TURN-ON TO 10K (mS max.) 10 5 150 35 TURN-OFF TO 100K (mS max.) 50 100 300 100
1.7 VDC LED 2.0 VDC LED INCAND. 12 VDC/AC 120 VDC/AC NEON
Add 47K Ohm external series resistor to limit current. PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION.
OUTLINE DIMENSIONS
1.93 Max. (49.2) 1.04 Max (26.5) .812 (20.6)
EMBOSSED SAFETY COVER
CLEAR COVER FOR CLASS 6 SOLID STATE RELAYS PREVENTS ELECTRICAL SHOCK HAZARDS FROM EXPOSED TERMINALS.
2.45 (62.3) 2.65 (67.4)
PART NUMBER
15-700
Weight:: 0.476 oz. (13.5 g)
NOT SUPPLIED WITH RELAY. TO BE ORDERED SEPARATELY IF REQUIRED.
WEBSITE: www.magnecraft.com - EMAIL:info@magnecraft.com - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
PAGE 108
Page 109
SECTION
5
5
TIME DELAY RELAYS AND SENSORS 5 TO 13 AMPERES
Magnecraft
Struthers-Dunn
TIME DELAY RELAYS
RELAY CLASS/SERIES 211 211 PROG 67 222
FEATURES
8 or 11 PIN OCTAL PLUG-IN. "ON DELAY" OR OFF DELAY" REPEATABILITY 0.1% FIELD ADJUSTABLE BY KNOB INTERVAL, FLASHER, ONE SHOT OR ON & OFF DELAY AVAILABLE
8 or 11 PIN OCTAL PLUG-IN. 4 PROGRAMMABLE FUNCTIONS 62 PROGRAMMABLE TIMING RANGES 4 INPUT VOLTAGE RANGES REPEATABILITY 0.1% FIELD ADJUSTABLE BY KNOB & DIP SWITCH DPDT 10 AMPS @ 120 VAC, 30VDC
MINIATURE PLUG-IN "ON DELAY" REPEATABILITY 2% FIELD ADJUSTABLE BY SCREW DRIVER 4 POLE STYLES AVAILABLE P.C. TERMINALS AVAILABLE..
8 PIN OCTAL PLUG-IN REPEAT CYCLE ON & OFF DELAY 0.1 % REPEATABILITY FIELD ADJUSTABLE TIMING USING KNOBS.
CONTACT DATA
CONTACT CONFIGURATION: CONTACT RATING:
DPDT 10 AMPS @ 120 VAC, 30VDC
DPDT 5AMPS @ 120 VAC, 28 VDC
DPDT 10 AMPS, 120VAC, 28 VDC
CONTACT MATERIAL CONTACT RESISTANCE:
Silver Cadmium Oxide 50 MILLIOHMS Max. Initial 1500 V rms 120 VAC 24 VDC AC - 90 to 130 DC - 20 to 32 DC MODELS ONLY
Silver Cadmium Oxide 50 MILLIOHMS Max. Initial 1500 V rms 120/24 VAC 24 VDC AC - 90 to 130 DC - 20 to 32 DC MODELS ONLY
Silver, Gold Overlay 50 Milliohms Max. Initial 1250 V rms AC On Special Order 12 & 24 VDC DC - 10 to 14, 20 to 32 DC MODELS ONLY
Silver cadimum Oxide 50 MILLIOHMS Max Initial 1500 V rms
INSULATION CHARACTERISTICS
DIELECTRIC STRENGTH:
COIL DATA
AC - VOLTAGE: DC - VOLTAGE: INPUT VOLTAGE RANGE REVERSE POLARITY PROTECTION: 120 VAC DC - SPECIAL ORDER 90 to 130 VAC
DC MODELS ONLY
GENERAL DATA
AMBIENT TEMPERATURE OPERATIONAL: STORAGE: TIMING VALUES OPERATE MAX.: RELEASE MAX: LIFE ELECTRICAL @ rated Load: MECHANICAL: - 30 C to + 55 C - 55 C to + 85 C 0.1 Seconds to 120 Minutes 0.1 Seconds to 15 Minutes 200,000 Operations 50,000,000 Operations H W L - 30 C to + 55 C - 55 C to + 85 C AS SELECTED AS SELECTED 200,000 Operations 50,000,000 Operations H W L - 30 C to + 80 C - 40 C to + 100 C 0.1 to 30 Seconds 50,000 Operations 50,000,000 Operations H W L 1.18 X .734 X 1.37 - 30 C to + 55 C - 55 C to + 85 C 0.1 Second to 30 Minutes 0.1 Second to 30 Minutes 200,000 Operations 50,000,000 Operations H W L .1.75 X 2.37 X 3.49
DIMENSIONS APPROVALS
APPLICATION DATA:
1.75 X 2..37 X 3.5"
1.75 X 2..37 X 3.5"
PAGE NUMBER
PAGE 113, 114 PAGE 115, 116
PAGE 117
PAGE 118
PAGE 119 PAGE 110
WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
Magnecraft
Struthers-Dunn
TIME DELAY RELAYS
388 SHORT BODY 388 KNOB ADJUSTMENT 388 TRUE OFF DELAY 286/287 326/327
SQUARE BASE PLUG-IN SQUARE BASE PLUG-IN OR FLANGE MOUNT ON DELAY OR OFF DELAY ON DELAY OR OFF DELAY 0.1 % REPEATABILITY 3 % REPEATABILITY FIELD ADJUSTABLE TIMING USING KNOB. FIELD ADJUSTABLE TIMING USING EXTERNAL RESISTOR INTERVAL, FLASHER, ONE SHOT OR ON & OFF DELAY AVAILABLE
SQUARE BASE PLUG-IN OFF DELAY 3 % REPEATABILITY FIELD ADJUSTABLE TIMING USING KNOB. POWER TO INPUT NOT REQUIRED DURING TIMING CYCLE.
RETANGULAR PLUG-IN 286 -ON DELAY, 287 0FF DELAY 3 % REPEATABILITY TIMING FIELD ADJUSTABLE BY KNOB OR EXTERNAL RESISTOR. 1, 2 & 3 POLE 10 AMP SWITCHING.
8 or 11 PIN OCTAL PLUG-IN. "ON DELAY" OR OFF DELAY" 3% REPEATABILITY FIELD ADJUSTABLE BY KNOB OR EXTERNAL RESISTOR. 1, 2 & 3 POLE 10 AMP SWITCHING.
DPDT 12 AMPS, 120VAC, 28 VDC
DPDT 12 AMPS, 120VAC, 28 VDC
DPDT 12 AMPS @ 120 VAC, 28 VDC
SPDT, DPDT, 3PDT 10 AMPS @ 120/240 VAC, 28 VDC
SPDT, DPDT, 3PDT 10 AMPS @ 120/240 VAC, 28 VDC
Silver cadimum Oxide 50 MILLIOHMS Max Initial 1500 V rms
Silver cadimum Oxide 50 MILLIOHMS Max Initial 2000 V rms
Silver Cadimum Oxide 50 MILLIOHMS Max.initial 2000 V rms
Silver Cadimum Oxide 50 MILLIOHMS Max.initial 1500 V rms
Silver Cadimum Oxide 50 MILLIOHMS Max.initial 1500 V rms
120 VAC 24 VDC 90 to 130 VAC 20 to 32 VDC DC MODELS ONLY
120 VAC 24 VDC 90 to 130 VAC 20 to 32 VDC DC MODELS ONLY
120 VAC 24 VDC 90 to 130 VAC 20 to 32 VDC DC MODELS ONLY
24 to 240VAC 12 to 115-125 VDC 85% Of Nominal 80% Of Nominal DC MODELS ONLY
24 to 240VAC 12 to 115-125 VDC 85% Of Nominal 80% Of Nominal DC MODELS ONLY
- 30 C to + 55 C - 55 C to + 85 C 0.1 to 120 Seconds 0.1 to 120 Seconds 100,000 Operations 5,000,000 Operations H W L 1.40 X 1.53 X 1.90
- 30 C to + 55 C - 55 C to + 85 C 0.1 to 120 Seconds 1.0 to 180 Seconds 100,000 Operations 5,000,000 Operations H W L 1.40 X 1.53 X 3.52 LG. 1.40 X 1.53 X 3.02 MED.
- 10 C to + 55 C - 55 C to + 85 C 0.6 to 60 Seconds 100,000 Operations 5,000,000 Operations H HW W L L 1.40 X 1.53 X 3.52
- 10 C to + 70 C 0.1 to 300 Seconds
- 10 C to + 70 C 0.1 to 300 Seconds
100,000 Operations 10,000,000 Operations H W L
100,000 Operations 10,000,000 Operations H W L
1.37 X .1.50 X 3.35
1.37 X 1.37 X 3.0
PAGE 120, 121 PAGE 111
PAGE 122, 123
PAGE 124
PAGE 125, 126
PAGE 127, 128
WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957, DOCUMENT 100 PAGE 91
Magnecraft
Struthers-Dunn
TIME DELAY RELAYS & SENSORS
236/237/238 246/247 235 CURRENT SENSOR 349 VOLTAGE SENSOR 236 VOLTAGE SENSOR
12 PIN STYLE PLUG-IN. WITH LOCKING CLIP
SEE SECTION 10 FOR SOCKETS
236 - ON DELAY, 237 OFF DELAY, 238 - ONE SHOT SCREWDRIVER OR EXTERNAL RESISTOR ADJUSTABLE. 10 % REPEATABILITY. 1,2 & 3 POLE 10 AMP SWITCHING SPDT, DPDT, 3PDT 10 AMPS @ 120/240 VAC, 28 VDC
SQUARE BASE PLUG-IN. 12 PIN STYLE PLUG-IN. WITH LOCKING CLIP 1.5 TO 15 AMP SENSING 85 to 135 VAC 50 TO 400 STYLE 246 - ON DELAY, RANGE. Hz SENSING RANGE. STYLE 247 - OFF DELAY 2% REPEATABILITY 1 AND 3 PHASE SENS3% REPEATABILITY. SPDT CONTACT ING. ARANGEMENTS 2 - 4 POLE CONTACT LARGE CHOICE OF ARANGEMENTS OPTIONS FIELD ADJUSTABLE WITH KNOB LARGE CHOICE OF OPTIONS 12 PIN STYLE PLUG-IN. WITH LOCKING CLIP
SQUARE BASE OR OCTAL PLUG-IN UP TO 552 VAC OR 30 VDC SENSING RANGE. 1% REPEATABILITY LED POWER INDICATOR FIELD ADJUSTABLE WITH SCREW DRIVER OR KNOB
SEE CATALOG PAGE 10 AMPS @ 120/240 VAC, 28 VDC
SPDT 10 AMPS @ 120VAC/ 28 VDC
SEE CATALOG PAGE 10 AMPS @ 120/240 VAC, 28 VDC
SPDT, DPDT 10 - 13 AMPS @ 120/240 VAC, 28 VDC
Silver Cadimum Oxide 50 MILLIOHMS Max.initial 1500 V rms
Silver Cadmium Oxide or Gold Diffused 50 MILLIOHMS Max. Initial 1500 V rms
Silver Cadmium Oxide 50 MILLIOHMS Max. Initial 2500 V rms
Silver Cadmium Oxide or Gold Diffused 50 MILLIOHMS Max. Initial 1500 V rms
Silver Cadmium Oxide 50 MILLIOHMS Max. Initial 2000 V rms
24 to 240VAC 12 to 115-125 VDC 85% Of Nominal 80% Of Nominal DC MODELS ONLY
24 to 240 VAC 12 TO 110-125 VDC DC MODELS ONLY
120 VAC -
120VAC N/A
120 to 480 VAC 24 VDC N/A
- 10 C to + 70 C 0.2 to 200 Seconds
- 10 C to + 70 C 0.1 to 300 Seconds
- 30 C to + 55 C - 40 C to + 85 C 1.5 to 15 Amps
- 10 C to + 60 C
- 30 C to + 55 C - 40 C to + 85 C SEE CATALOG PAGE
85 TO 135 VAC
100,000 Operations 10,000,000 Operations H W L
100,000 Operations 10,000,000 Operations H W L 1.46 X 2.62 X 4.42
200,000 Operations 5,000,000 Operations H W L 1.40 X 1.53 X 3.52
100,000 Operations 10,000,000 Operations H W L 1.46 X 2.62 X 4.56
100,000 Operations 5,000,000 Operations H W L 1.75 X 2.37 X 3.49 1.40 X 1.53 X 2.90
1.46 X 2.62 X 4.56
PAGE 129, 130
PAGE 131
PAGE 132
PAGE 133
PAGE 134, 135 PAGE 112
WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
DESCRIPTIONS OF TIME DELAY FUNCTIONS
WHAT A TIME DELAY RELAY IS:
APPLICATION DATA
TIMING FUNCTIONS (Continued) ONE SHOT (MOMENTARY ACTUATION) Continuous power must be applied to the input during all timing sequences. Upon closure of external control Switch, output contacts transfer and timing period begins. When timing period ends, output contacts return home. Once the timing period begins, the control switch may remain closed or opened without affecting timing. To repeat this cycle, the control switch must be open, or opened at the end of the timing period, and then closed to start timing period over again.
INPUT POWER CONTROL SWITCH OUTPUT CONTACTS DELAY DELAY ON OFF CLOSED OPEN TRANSFERRED HOME
A Time Delay relay is a combination of an electromechanical output relay and a control circuit. The control circuit is comprised of solid state components and timing circuits that control operation of the relay and timing range. Typical time delay functions include On-Delay, Off-Delay, Repeat cycle, One Shot, Batch Control Interval, On-Delay & Off Delay (Combination) and True Off Delay. Each function is explained below. Time delay relays have a broad choice of timing ranges from less than one second to hours. There is a choice of timing controls from calibrated external knob, screwdriver adjusted or internally fixed timing for specific applications. The output contacts on the electromechanical output relay are direct wired to the output terminals. The contact load ratings are specified for each specific type of time delay relay. TIMING FUNCTIONS: ON-DELAY- (SLOW OPERATE RELAY) Upon application of power to the input, the time delay period begins. At the end of the time delay period, output contacts transfer. Input power must be removed to return output contacts to home position and reset the control circuit. If input power is interrupted before a timing period ends, timing stops. When input power is restored , timing starts from the beginning. Special requirements for Class 211 programmable relays: To function as an On-Delay timer, as described above, a jumper wire must be connected in place of the external control switch.
INPUT POWER OUTPUT CONTACTS DELAY ON OFF TRANSFERRED HOME
Some typical Applications: Vending machines, dispensing controls, machine control, welding control, BATCH CONTROL (INTERVAL) Upon application of power to the input, the output contacts transfer and the delay period begins. At the end of the time delay period, the output contacts return home. Input power must be interrupted to recycle timer.
INPUT POWER OUTPUT CONTACTS DELAY ON OFF TRANSFERRED HOME
Some typical Applications: Cascade starting, Air Conditioning & heating controls, Burglar Alarms, Power Outage delay, instrument Control. OFF-DELAY (SLOW RELEASE RELAY) Continuous power must be applied to input during all timing sequences. Upon closure of external control switch, output contacts transfer. Upon opening control switch, the timing period begins. When timing period ends, output contacts return home. To repeat this timing cycle, the control switch must be re-closed and then opened. If input power is interrupted during timing cycle, the output contacts return to home position and the control switch must be closed and reopened to start the timing from the beginning. If the control switch closes during a timing period, timing stops and output contacts remain transferred. When control switch is opened, timing will start again from the beginning. The timing period can be extended, repeatedly using the control switch in this way until the last initiated timing period is permitted to end and output contacts return home.
INPUT POWER CONTROL SWITCH OUTPUT CONTACTS DELAY ON OFF CLOSED OPEN TRANSFERRED HOME
Some typical Applications: Machine control, End of process alarm, Welding control, Photographic timing. ON-DELAY & OFF-DELAY- (COMBINATION) Continuous power must be applied to the input during all timing sequences. Upon closure of the external control switch, first time delay period T1 begins. When T1 period ends, output contacts transfer. Then, When control switch is opened, second delay period T2 begins. When T2 ends, output contacts return home. To repeat this timing cycle, repeat this sequence from the beginning. If the prevailing open or closed status of the control switch is changed during either T1 or T2 Timing periods, timing stops. Position of output contacts remain as they were. Returning control switch to its pre-changed position restarts interrupted timing period from the beginning and normal timing resumes.
INPUT POWER CONTROL SWITCH OUTPUT CONTACTS T1 T2 T1 Interrupted ON OFF CLOSED OPEN TRANSFERRED HOME T2 Interrupted CLOSED OPEN
DELAY
CONTROL SWITCH OUTPUT CONTACTS T1 T2
TRANSFERRED HOME
Some typical Applications: Air Conditioning, automatic Door Controls, Lighting Controls, burglar alarms, Vending Machines, conveyor systems, instrument control. REPEAT CYCLE (FLASHER) - Upon application of power to the input, the Off time delay Period begins. The contacts transfer at the end of the Off time Delay Period and the ON time delay period begins. At the end of the ON time delay period output contacts return home and OFF time delay period begins again. This sequence will continue as long as input power is supplied to the Input Pins.
INPUT POWER OUTPUT CONTACTS ON DELAY ON DELAY ON OFF TRANSFERRED HOME
Some typical Applications: Cascade starting & stopping of heavy loads, laboratory equipment, machine control TRUE OFF DELAY- (SLOW RELEASE) Upon application of power to the input, output contacts transfer. The delay period begins when power is removed from the input. If power is supplied to input during the timing period, time is reset and time delay period starts over again when power is removed from the input.
INPUT POWER OUTPUT CONTACTS ON OFF TRANSFERRED HOME
OFF DELAY
DELAY OFF DELAY
Some typical Applications: Signs, Product testing, signal devices, machine control, Signal warning devices, conveyor control.
Some typical Applications: Loss of power alarm control, Burglar alarms.
PAGE 113
WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
APPLICATION DATA
SELECTING A TIMER'S MODE OF OPERATION
TIME DELAY RELAYS & SENSORS
Selecting the correct Mode of operation (Timing Function) can be easily done by following the ladder diagram below. When selecting the proper relay for your application, you must determine if the timer will be controlled by input power only, or the use of an external switch. The next item to take into consideration is the load status during the timing cycle(s), and the contact status after the timing cycle.
Timing Starts When?
Power is supplied to Input
Power is supplied to Input & External Switch ON/OFF
Output status During Timing cycle (s).
OFF
ON NOTE 1
ON/OFF
ON
ON
ON NOTE 3
OFF NOTE 4
Load Status at end of First Timing cycle.
ON
OFF
ON NOTE 2
OFF
OFF
OFF
ON
Load Status at end of Second Timing cycle.
OFF NOTE 2
OFF NOTE 5
Timer Type.
ON DELAY
TRUE OFF DELAY
REPEAT CYCLE
BATCH CONTROL (INTERVAL) 238ABX
OFF DELAY
ONE SHOT
ON/OFF DELAY
Applicable Time delay relays that apply to Mode of Operation
211PROGX 211 SOX 67 SOX 326X 388 SOX 236X 246XBX 286X
388 SRX
222 PFX
211PROGX 211 SRX 237X 327X 388 SRX 247XBX 287X
211PROGX 238X
211PROGX
NOTES: 1. Momentary power supplied to the input. Input power not required for timing cycle. 2. Continues to repeat timing cycles until power is removed from input 3. Upon closure of External switch, relay contacts switch and time period begins. The timing is not affected by the duration of the External switch closure. 4. External switch is maintained closed, relay contacts switch at the end of first timing cycle. 5. External switch is maintained open for second timing cycle.
Footnote: ON = Relay coil energized, contacts switched. OFF = Relay coil de-energized, contacts in normal position.
WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
PAGE 114
CLASS
211
OCTAL 8 & 11 PIN TIME DELAY RELAY
CLASS 211
0.1 % REPEATABILITY
DPDT, 10 AMP CONTACTS FIELD ADJUSTABLE TIMING
WHEN USED WITH SOCKET 70-464-1 (8PIN) 70-465-1 (11 PIN)
UL Recognized COMPLIES WITH File No: E43641 REQUIREMENTS OF * IEC STANDARDS 947-4-1 AND 947-5-1 LOW VOLTAGE DIRECTIVE. *1EC = INTERNATIONAL ELECTROTECHNICAL COMMISSION
THE CLASS 211 TIME DELAY RELAY MAKES USE OF HYBRID CIRCUITRY, COMBINING INTEGRATED CIRCUITS FOR A MULTITUDE OF TIMING FUNCTIONS, AND THE RELIABILITY OF RELAY TECHNOLOGY.
* RELEVANT IEC CONTACT UTILIZATION CATEGORIES
AC-1, AC-3, DC-1, AC-15
(SEE SECTION 11 FOR RELEVANT UTILIZATION CATEGORIES.)
SPECIFICATIONS CLASS 211 TIME DELAY RELAYS TIMING Operating Modes Available: Timing Adjustments Available: Repeatability (repeat Accuracy when Stabilized):
On Delay, Off Delay 0.1 to 1 Sec, thru 8 to 120 Minutes 0.1% max. or 33 mS AC min. or 10 mS DC. min.@ Constant voltage & temperature 10% - 0 to + 40% + 0 to - 40% 100 Milliseconds Max.
Timing change over temperature and voltage range: Timing Tolerance high end of range: Timing Tolerance low end of range:: Reset time: CONTACTS Contact Configuration:: Contact Rating:
DPDT (2 Form C) 10 Amps @ 120VAC/30VDC Resistive Load, 1/2 Hp @ 240 VAC, 1/3 Hp @120 VAC, NEMA B300 Pilot Duty. 200,000 Operations @ 120VAC, 10Amp resistive Load. 1,000,000 Operations @ 120 VAC,5 Amp Resistive Load 2,000,000 Operations @ 120VAC, 2 Amps Resistive Load. 50,000,000 Operations.
Contact Life:
Mechanical Life: INPUT Temperature Range (Operate): Temperature Range (Storage): Steady State Input Current:
- 30 C to + 55C - 55C to + 85C 20 mA @ 120 VAC, 40 mA @ 24 VDC, 20 mA @ 48 VDC 80 mA @ 24 VDC, 15 mA @ 230 VAC, 80 mA @ 12 VDC. DC models only UL 508 Surge test: 5000V for 50 uS NEMA ICS2-230 2500 VAC
PROTECTION Reverse Polarity: Transient: Noise Immunity: DIELECTRIC STRENGTH Coil to Contacts: Across Open Contacts: MECHANICAL Enclosure: Mounting: Operating Position: Weight:
1500 V rms 1000 V rms
Polycarbonate dust cover. Standard 8 or 11 Pin Octal Any 4 oz. (115 grams)
WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
PAGE 115
OCTAL 8 & 11 PIN TIME DELAY RELAY
CLASS
211
OUTLINE DIMENSIONS Dimensions shown in Inches and (Millimeters) WIRING DIAGRAMS VIEWED FROM PIN END
.562 (14.2)
w v w v
4
5 6 7
ON DELAY
3 2 1 8
2.93 (74.4)
INPUT
2.37 (60.3)
EXTERNAL TRIGGER SWITCH
q q
6 5 4
7 8 1
1.75 (44.4)
v
5
6
7 8 9 10
w v
OFF DELAY
w v
4 3 2 1 11
3
2
8 PIN OCTAL ON-DELAY
INPUT EXTERNAL SWITCH SHALL NOT BE CONNECTED TO ANY EXTERNAL LOAD OR VOLTAGE. DAMAGE TO INTERNAL COMPONENTS CAN OCCUR.
8 7 6 5 4
9
10 11
1.75 (44.4)
1 3 2
11 PIN OCTAL OFF-DELAY
PART NUMBERS ON DELAY W211ACPSOX-18 W211ACPSOX-5 W211ACPSOX-7 W211ACPSOX-8 W211ACPSOX-60 W211ACPSOX-61 W211ACPSOX-62 W211ACPSOX-63 W211CPSOX-1 W211CPSOX-3 OFF DELAY W211ACPSRX-5 W211ACPSRX-7 W211ACPSRX-8 W211ACPSRX-60 W211CPSRX-1 W211CPSRX-3 120 VAC 120 VAC 120 VAC 120 VAC 24 VDC 24 VDC 0.1 to 10 Seconds 1.0 to 180 Seconds 2.0 to 300 Seconds 1.0 to 15 Minutes 0.1 to 10 Seconds 1.0 to 180 Seconds CHB-38-70011 CHB-38-70013 CHD-38-30011 CHD-38-30013 120 VAC 120 VAC 120 VAC 120 VAC 120 VAC 120 VAC 120 VAC 120 VAC 24 VDC 24 VDC 0.1 to 1.0 Seconds 0.1 to 10 Seconds 1.0 to 180 Seconds 2.0 to 300 Seconds 1.0 to 15 Minutes 2.0 to 30 Minutes 4.0 to 60 Minutes 8.0 to 120 Minutes 0.1 to 10 Seconds 1.0 to 180 Seconds CDB-38-70001 CDB-38-70003 * CDB-38-70005 * CGB-38-70005M CGB-38-70010M CGB-38-70050M CB-1007B70 CDD-38-30003 * CDD-38-30005 * NOMINAL INPUT VOLTAGE TIMING RANGE CROSS REFERENCE TO POTTER & BRUMFIELD
* ADDITIONAL EQUIVALENTS
W211ACPSOX-5 CGB-38-70010S CHB-38-70001 CKB-38-70010 CB-1003B-70 W211ACPSOX-7 CKB-38-70180 CHB-38-70003 CB-1005B-70
TO P&B
W211CPSOX-1 CHD-38-30001 CB-1028D-30
W211CPSOX-3 CHD-38-30003 CB-1030D-30
SEE SECTION 10 FOR MATING SOCKETS
PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION.
WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
PAGE 116
CLASS
211PROGX
PROGRAMMABLE TIME DELAY RELAY
CLASS 211 PROGRAMMABLE TIME DELAY RELAY
0.1 % REPEATABILITY
3 INPUT VOLTAGE RANGES | 4 PROGRAMMABLE FUNCTIONS | 62 PROGRAMMABLE TIMING RANGES RATED AT 10 AMPS, DPDT CONTACTS
SEE SECTION 10 FOR MATING SOCKETS
| SELECTION OF TIMING RANGE AND TIMING FUNCTIONS ARE OBTAINED BY SETTING SWITCH POSITIONS IN A DIP SWITCH BANK
WHEN USED WITH SOCKET 70-465-1
THE CLASS 211 TIME DELAY RELAY MAKES USE OF HYBRID CIRCUITRY, COMBINING INTEGRATED CIRCUITS FOR A MULTITUDE OF TIMING FUNCTIONS, AND THE RELIABILITY OF RELAY TECHNOLOGY.
UL Recognized File No: E43641
* RELEVANT IEC CONTACT UTILIZATION CATEGORIES
AC-1, AC-3, DC-1, AC-15
(SEE SECTION 11 FOR RELEVANT UTILIZATION CATEGORIES.)
COMPLIES WITH REQUIREMENTS OF * IEC STANDARDS 947-4-1 AND 947-5-1 LOW VOLTAGE DIRECTIVE. *1EC = INTERNATIONAL ELECTROTECHNICAL COMMISSION
OUTLINE DIMENSIONS Shown in Inches and (Millimeters)
.562 (14.2)
SPECIFICATIONS CLASS 211PROG TDR TIMING Operating Modes Available: Timing Adjustments Available: Repeatability (repeat Accuracy when Stabilized): Timing change over temperature and voltage range: Timing Tolerance: Reset time: CONTACTS Contact Configuration: Contact Rating:
On Delay, Off Delay, One Shot, On & Off Delay 0.1 to 1 Sec, thru 12 to 120 Minutes 0.1% max. or 33 mS AC min., or 10 mS DC. 10% 20 % 100 mS Relay On (200 mS max Relay Off) DPDT (2 Form C) 10 Amps @ 120VAC/30VDC Resistive Load, 1/2 Hp @ 240 VAC, 1/3 Hp @ 120 VAC, NEMA B300 Pilot Duty. 200,000 Operations @ 120VAC, 10 Amp resistive Load. 1,000,000 Operations @ 120VAC, 5 Amp Resistive Load 2,000,000 Operations @ 120VAC, 2 Amps Resistive Load. 100,000,000 Operations. - 30 C to + 55C - 40C to + 85C 45 mA Max.. Yes UL 508 Surge test: 5000V for 50 uS NEMA ICS2-230 2500VAC 1500 V rms 1000 V rms Polycarbonate dust cover. Standard 11 Pin Octal Any 4 oz. (115 grams)
2.93 (74.4)
Contact Life:
2.37 (60.19)
9
3
q
Mechanical Life: INPUT Temperature Range (Operate): Temperature Range (Storage): Steady State Input Current: PROTECTION Reverse Polarity: Transient: Noise Immunity: DIELECTRIC STRENGTH Coil to Contacts: Across Open Contacts: MECHANICAL Enclosure: Mounting: Mounting Position: Weight:
10
4
2
11 PIN OCTAL PLUG-IN
WIRING DIAGRAMS VIEWED FROM PIN END ** EXTERNAL CONTROL
SWITCH
q
1
11
5
w v
4 3 2 1 11
INPUT 120VAC 50/60 Hz
To function as a On-Delay timer, a jumper wire must be connected in place of the external control switch.
PAGE 117
WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
8
7
1.75 (44.45)
6
5
v
+
6 7 8 9 10
w v
24VAC/VDC
-
NOMINAL TIMING INPUT RANGE VOLTAGE ON DELAY, OFF DELAY, ONE SHOT, ON & OFF DELAY 62 Programmable 120 VAC, 50/60Hz W211PROGX-1 Timing Ranges. 24VAC/VDC on Pin 7 PART NUMBER PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION. **EXTERNAL CONTROL SWITCH REQUIRED FOR OFF DELAY, ONE SHOT AND
ON & OFF DELAY FUNCTIONS. EXTERNAL SWITCH SHALL NOT BE CONNECTED TO ANY EXTERNAL LOAD OR VOLTAGE. DAMAGE TO INTERNAL COMPONENTS CAN OCCUR.
MINIATURE 5 AMP TIME DELAY RELAY
CLASS 67 TIME DELAY RELAY
2% REPEATABILITY
UL Recognized File No: E43641
CLASS
67
DC OPERATION PLUG-IN/SOLDER TERMINALS
SPECIFICATIONS CLASS 67 TIME DELAY RELAYS
TIMING Operating Modes Available: Timing Adjustments Available: Repeatability (repeat Accuracy when Stabilized): Reset time: CONTACTS Contact Configuration: Contact Rating: Contact Life:
On Delay, 0.1 to 240 Seconds 2% max. @ Nominal Voltage, 25C 100 Milliseconds Max DPDT ( 2 Form "C"). 5 Amps @ 120VAC/28 VDC Resistive 50,000 Operations @ 120 VAC 5 Amps Resistive 1,500,000 Operations @ 120VAC, 2 Amps resistive Load. 12,000,000 Operations @ 120 VAC 1Amp Resistive Load 50,000,000 Operations 12 VDC, 24 VDC -30C to + 55C -50C to +85C 40 mA @ 24 VDC, 80 mA @ 12 VDC DC models only Twice Nominal Voltage for 1 Millisecond 500 V rms 1250 V rms Polycarbonate dust cover. Socket Plug-in/Solder. Also Available with P.C. Terminals. 1.2 oz. 35.2 Grams Use 6 Pole Socket with plug-in style relays. . OUTLINE DIMENSIONS Dimensions shown are in Inches and ( Millimeters).
1.37 (34.9) .734 (18.6)
1.18 Max. (30.2)
Mechanical Life: INPUT Nominal Input Voltage: Temperature Range (Operate): Temperature Range (Storage): Steady State Input Current: PROTECTION Reverse Polarity: Transient: DIELECTRIC STRENGTH Coil to Contacts: Across Open Contacts: MECHANICAL Enclosure: Mounting: Weight: Special Note:
.094 (2.3) .170 (4.3) Elongated Hole .100 x .040 ( 2 x .1) All Contact Terminals are .010 Thick all coil terminals are .018 Thick. 3-48UNC-2A Thd.
.400 (10.1) .458 (11.6)
.200 Max. (5.1)
WIRING DIAGRAM
16 6 7
14
15
5
+ 1 4 VIEWED FROM PIN END
PART NUMBERS "ON" DELAY W67CPSOX-1 W67CPSOX-2
NOMINAL INPUT VOLTAGE 12 VDC 24 VDC
TIMING RANGE
CROSS REFERENCE TO POTTER & BRUMFIELD
.280 (7.11)
.56 (14.2)
CHASSIS CUTOUT for panel mounting.
.790 (19.8)
0.1 to 30 Seconds R12-3012X2E1 0.1 to 30 Seconds R12-3024X2E1
.352 (8.9)
.656 (16.7)
PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION
OTHER COIL VOLTAGES, TIMING RANGES, P.C. TERMINALS AND 4PDT CONTACT COMBINATION AVAILABLE ON SPECIAL ORDER. 120 VAC INPUT DESIGN AVAILABLE, CONTACT FACTORY.
.140 (3.5)
.109 DIA. (2.77)
SEE SECTION 10 FOR MATING SOCKETS
WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
PAGE 118
CLASS
222
OCTAL 8 PIN REPEAT CYCLE TIMER
CLASS 222
0.1 % REPEATABILITY
DPDT, 10 AMP CONTACTS FIELD ADJUSTABLE ON AND OFF TIME.
SEE SECTION 10 FOR MATING SOCKETS
UL Recognized File No. E43641
COMPLIES WITH REQUIREMENTS OF * IEC STANDARDS 947-4-1 AND 947-5-1 LOW VOLTAGE DIRECTIVE. *1EC = INTERNATIONAL ELECTROTECHNICAL COMMISSION
* RELEVANT IEC CONTACT UTILIZATION CATEGORIES
AC-1, AC-3, DC-1, AC-15
(SEE SECTION 11 FOR RELEVANT UTILIZATION CATEGORIES.)
SPECIFICATIONS CLASS 222 REPEAT CYCLE TIMER
THE CLASS 222 REPEAT CYCLE TIME DELAY RELAY CAN BE ADJUSTED TO ACHIEVE INDEPENDENT TIME SETTINGS FOR BOTH "ON" AND "OFF" TIMING RANGES.
TIMING Operating Modes Available: Timing Adjustments Available: Repeatability (repeat Accuracy when Stabilized): Timing change over temperature and voltage range: Timing Tolerance high end of range: Timing Tolerance low end of range:: Reset time:
Repeat cycle timing only. 0.1 to 1 Sec, to 24 hours 0.1% max. or 33 mS AC min. or 10 mS DC min. at constant voltage & temperature.. 10% - 0 to + 40% + 0 to - 40% 100 Milliseconds Max. DPDT (2 Form C) 10 Amps @ 120VAC/30VDC Resistive Load, 1/2 Hp @ 240 VAC, 1/3 Hp @ 120 VAC, NEMA B300 Pilot Duty. 200,000 Operations @ 120VAC, 10Amp resistive Load. 1,000,000 Operations @ 120 VAC 5 Amp Resistive Load 2,000,000 Operations @ 120VAC 2 Amps Resistive Load. 50,000,000 Operations. - 30 C to + 55C - 55C to + 85C 25 mA @ 120 VAC, 45 mA @ 24 VDC, 24 mA @ 48 VDC 85 mA @ 24 VDC, 25 mA @ 230 VAC. DC models only UL 508 Surge test: 5000V for 50 uS NEMA ICS2-230 2500VAC 1500 V rms 1000 V rms Polycarbonate dust cover. Standard 8 Pin Octal Any 5 oz. (132 grams)
.562 (14.2)
CONTACTS Contact Configuration: Contact Rating:
2.93 (74.4)
Contact Life:
Mechanical Life: INPUT Temperature Range (Operate): Temperature Range (Storage): Steady State Input Current:
2.37 (60.3)
6 5 4 3 2 7 8 1
1.75 (44.4)
PROTECTION Reverse Polarity: Transient: Noise Immunity: DIELECTRIC STRENGTH Coil to Contacts: Across Open Contacts: MECHANICAL Enclosure: Mounting: Mounting Position: Weight:
8 PIN OCTAL ON-DELAY
WIRING DIAGRAMS VIEWED FROM PIN END
w v w v
4 3 2 1
5 6 7 8
PART NUMBERS REPEAT CYCLE W222ACPFX-11 W222ACPFX-16 W222ACPFX-27
INPUT
NOMINAL INPUT VOLTAGE 120 VAC 120 VAC 120 VAC
TIMING RANGE "ON" (T1) TIMING
TIMING RANGE "OFF" (T2) TIMING 0.1 to 10 Seconds 3 to 300 Seconds 2 to 30 Minutes
CROSS REFERENCE TO POTTER & BRUMFIELD CRB-48-70010 -
0.1 to 10 Seconds 3 to 300 Seconds 2 to 30 Minutes
PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION.
OTHER VOLTAGES AND TIMING RANGES AND AVAILABLE THRU SPECIAL ORDER. CONTACT FACTORY.
PAGE 119
WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
12 AMP ADJUSTABLE TIME DELAY RELAY
CLASS 388 SHORT BODY EXTERNAL RESISTANCE ADJUSTABLE
3 % REPEATABILITY DPDT, 12 AMP CONTACTS FIELD ADJUSTABLE TIMING "ON" or "OFF" DELAY FUNCTIONS
CLASS
388
UL Recognized File No: E43641
COMPLIES WITH REQUIREMENTS OF * IEC STANDARDS 947-4-1 AND 947-5-1 LOW VOLTAGE DIRECTIVE. *1EC = INTERNATIONAL ELECTROTECHNICAL COMMISSION
* RELEVANT IEC CONTACT UTILIZATION CATEGORIES
AC-1, AC-3, DC-1, AC-15
(SEE SECTION 11 FOR RELEVANT UTILIZATION CATEGORIES.)
PLUG-IN STYLE
SPECIFICATIONS CLASS 388 TIME DELAY RELAYS TIMING Operating Modes Available: Timing Adjustments Available: Repeatability: Percent Timing change over temperature and voltage Range: Timing Tolerance high end Timing Tolerance low end: CONTACTS Contact Configuration: Contact Rating:
On Delay, Off Delay .1 to 1 Seconds to 24 Hours 0.1% max. or 33 mS AC min. or 10 mS DC.@ Constant Voltage & Temperature. 10% - 0 to + 40% + 0 to - 40%
FLANGE MOUNT STYLE
DPDT (2 Form C) 12 Amps @ 120 VAC/28 VDC Resistive 1/3 HP, 120 VAC, 1/2 HP, 240 VAC B300 Pilot Duty. 100,000 Operations @ 120 VAC 12 Amps Resistive Load. 1,000,000 Operations @ 28 VDC 5 Amps Resistive Load. 5,000,000 Operations
Contact Life: Mechanical Life: INPUT Temperature Range (Operate): Temperature Range (Storage): Steady State Input Current: PROTECTION Reverse Polarity: Transient: DIELECTRIC STRENGTH Coil to Contacts: Across Open Contacts: MECHANICAL Enclosure: Operating Position: Weight:
- 30 C to + 55C - 55C to + 85C 20 mA @ 120 VAC, 60 mA @ 24 VDC,
DC models only Twice nominal voltage for 1 millisecond
1500 V rms 1000 V rms
Polycarbonate dust cover. Any 3 oz. 96 grams
WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
PAGE 120
CLASS
388
12 AMP ADJUSTABLE TIME DELAY RELAY
OUTLINE DIMENSIONS
Dimensions Shown in "Inches " & (Millimeters). 2.90 Max. (73.8) 2.50 (63.5)
1.53 Max. (38.8)
1.90 Max. (48.4)
.187 (4.74) Q.C. Terminals
1 4 1.40 Max. (35.7) 7 A
2 5 8
3 6 9 B
THE PLUG-IN STYLE TIMER HAS THE SAME CASE DIMENSIONS AS THE FLANGE MOUNT STYLE EXCEPT IT HAS NO FLANGE AND IT IS ALSO SOCKET MOUNTABLE.
WIRING DIAGRAMS FOR FIXED STYLE TIME DELAY RELAYS Voltage must be applied to terminals "A" & "B" continuously.
EXTERNAL RESISTOR EXTERNAL RESISTOR
1 4
2 5
3 6
1 4
2 5
3 6
7 A
8
EXTERNAL SWITCH
9 B
7 A
8
9 B
+ INPUT OFF DELAY
+ INPUT ON DELAY
THE EXTERNAL TRIGGER SWITCH SHOULD NOT BE CONNECTED TO ANY EXTERNAL LOAD OR VOLTAGE SOURCE. DAMAGE TO INTERNAL COMPONENTS CAN OCCUR.
NOMINAL TIMING EXTERNAL INPUT RANGE RESISTOR VOLTAGE ON DELAY PLUG-IN STYLE 0.1 to 10 Seconds W388ACPSOX-1 120 VAC 20K OHMS 1.0 to 120 Seconds PER SECOND W388ACPSOX-2 120 VAC 16 K OHMS 0.1 to 10 Seconds W388CPSOX- 1 24 VDC 1.0 to 120 Seconds PER SECOND W388CPSOX-2 24 VDC ON DELAY SURFACE MOUNT FLANGE STYLE 0.1 to 10 Seconds W388ACQSOX-1 120 VAC 20 K OHMS 1.0 to 120 Seconds PER SECOND W388ACQSOX-2 120 VAC 1.0 to 120 Seconds W388CQSOX-2 24 VDC OFF DELAY PLUG-IN STYLE 1.0 to 120 Seconds 16K per Second W388CPSRX-22 24 VDC PART NUMBER
CROSS REFERENCE TO POTTER & BRUMFIELD CUF-41-70010 CUF-41-70120 CUH-41-30010 CUH-41-30120 CUF-42-70010 CUF-42-70120 CUH-42-30120 -
PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION.
SEE SECTION 10 FOR MATING SOCKETS PAGE 121 WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
12 AMP ADJUSTABLE TIME DELAY RELAY
CLASS 388 ADJUSTABLE
UL Recognized File No: E43641 COMPLIES WITH REQUIREMENTS OF * IEC STANDARDS 947-4-1 AND 947-5-1 LOW VOLTAGE DIRECTIVE.
CLASS
388
CHOICE OF LONG or MEDIUM BODY 0.1 % REPEATABILITY DPDT, 12 AMP CONTACTS FIELD ADJUSTABLE TIMING "ON" or "OFF" DELAY FUNCTIONS
*1EC = INTERNATIONAL ELECTROTECHNICAL ICOMMISSION * RELEVANT IEC CONTACT UTILIZATION CATEGORIES AC-1, AC-3, DC-1, AC-15
(SEE SECTION 11 FOR RELEVANT UTILIZATION CATEGORIES.)
SPECIFICATIONS CLASS 388 TIME DELAY RELAYS TIMING Operating Modes Available: Timing Adjustments Available: Repeatability: Timing change over temperature and voltage Range: Timing Tolerance high end: Timing Tolerance low end: Reset Time: CONTACTS Contact Configuration: Contact Rating:
On Delay, Off Delay .1 to 1 Seconds to 8 to 120 Minutes 0.1% 33 mS AC min. or 10 mS DC. @ Constant Voltage & Temperature. 10% - 0 to + 40% + 0 to - 40% 100 mS Max.
DPDT (2 Form C) 12 Amps @ 120 VAC/28 VDC Resistive 1/3 HP, 120 VAC, 1/2 HP, 240 VAC NEMA B300 Pilot Duty. 100,000 Operations @ 120 VAC 12 Amps Resistive Load. 1,000,000 Operations @ 120 VAC 5 Amps Resistive Load 2,000,000 Operations @ 120 VAC 2 Amps Resistive Load. 5,000,000 Operations
Contact Life:
Mechanical Life: INPUT Temperature Range (Operate): Temperature Range (Storage): Steady State Input Current:
- 30 C to + 55C - 55 C to + 85C 20 mA @ 120 VAC, 60 mA @ 24 VDC, 20mA @ 48 VDC, 80 mA @ 24 VAC, 15 mA @ 230 VAC, 120mA @ 12 VDC
PROTECTION Reverse Polarity: Transient: Noise Immunity: DIELECTRIC STRENGTH Coil to Contacts: Across Open Contacts: MECHANICAL Enclosure: Terminals: Mounting Position: Weight:
DC models only UL 508 Surge test: 5000V for 50 uS (Long Body Only). Twice Nominal for 1 Millisecond (Medium Body Only). NEMA ICS2-230: 2500 VAC (Long Body Only).
2000 V rms 1000 V rms
Polycarbonate dust cover. 3/16" Q.C. Terminals. P.C. Available. Any Aprox. 4 oz., 96 grams
WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
PAGE 122
CLASS
388
12 AMP ADJUSTABLE TIME DELAY RELAY
OUTLINE DIMENSIONS
Dimensions are Shown In Inches and (Millimeters).
1 4
2 5
3 6
7 A
8
9 B
1.40 (35.7)
1.53 (38.8)
.312 (7.9)
.625 2.90 Max. (Long Body) (15.8) (73.8) 2.40 Max. (Medium Body) (61.1)
WIRING DIAGRAMS FOR ADJUSTABLE STYLE TIME DELAY RELAYS Voltage must be applied to terminals "A" & "B" continuously.
EXTERNAL TRIGGER SWITCH
1 4
2 5
3 6
1 4
2 5
3 6
1 4
2 5
EXTERNAL TRIGGER SWITCH
3 6
7 A
8
9 B
7 A
+
8
9 B
7 A
8
9 B
+ INPUT OFF DELAY LONG BODY
INPUT
-
ON DELAY LONG & MEDIUM BODY
INPUT + OFF DELAY MEDIUM BODY
THE EXTERNAL TRIGGER SWITCH SHOULD NOT BE CONNECTED TO ANY EXTERNAL LOAD OR VOLTAGE SOURCE. DAMAGE TO INTERNAL COMPONENTS CAN OCCUR.
PART NUMBERS
NOMINAL INPUT VOLTAGE
TIMING RANGE
CROSS REFERENCE TO POTTER & BRUMFIELD CLB-51-70120 * -
ON DELAY - LONG BODY 0.1 to 10 Seconds 120 VAC W388ACPSOX-42 1.0 to 180 Seconds 120 VAC W388ACPSOX-44 OFF DELAY - LONG BODY W388CPSRX-2 24 VDC 0.1 to 10 Seconds W388CPSRX-4 24VDC 1.0 to 180 Seconds OFF DELAY - MEDIUM BODY W388ACPSRX-101 120 VAC 1.0 to 120 Seconds ON DELAY - MEDIUM BODY W388ACPSOX-101 120 VAC 1.0 to 120 Seconds OFF DELAY - MEDIUM BODY W388CPSRX-23 24 VDC 1.0 to 120 Seconds ON DELAY - MEDIUM BODY W388CPSOX-101 24 VDC 1.0 to 120 Seconds
* THE CASE LENGTH ON THE MAGNECRAFT MEDIUM BODY IS 2.40 LONG VS P&B, 2.156 LONG.
PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION.
SEE SECTION 10 FOR MATING SOCKETS PAGE 123 WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
ADJUSTABLE TRUE OFF DELAY RELAY
UL Recognized File No: E43641 COMPLIES WITH REQUIREMENTS OF * IEC STANDARDS 947-4-1 AND 947-5-1 LOW VOLTAGE DIRECTIVE. *1EC = INTERNATIONAL ELECTROTECHNICAL COMMISSION
CLASS
388
CLASS 388 TRUE OFF DELAY
DOES NOT REQUIRE CONTROL POWER DURING TIMING CYCLE 3% REPEAT TIMING ACCURACY FIELD ADJUSTABLE
* RELEVANT IEC CONTACT UTILIZATION CATEGORIES
AC-1, AC-3, DC-1, AC-15
(SEE SECTION 11 FOR RELEVANT UTILIZATION CATEGORIES.)
SPECIFICATIONS CLASS 388 TRUE OFF DELAY TIMING Operating Modes Available: Timing Adjustments Available: Repeatability: Reset time: INPUT Temperature Range Operate: Temperature Range Storage: Input Current: CONTACTS Contact Configuration: Contact Rating: Contact Life: True Off Delay 0.1 to 10 Seconds thru 0.5 to 5 Minutes 3% @ Nominal Voltage & 25C 100 mS Max. - 10C to + 55C - 40C to + 85C 10 mA @ 120VAC, 15 mA @ 24VDC fixed DPDT (2 Form C) 12 Amps @ 120 VAC/28 VDC Resistive 1/3 HP, 120 VAC, 1/2 HP, 240 VAC NEMA B300 Pilot Duty. 100,000 Operations @ 120 VAC 12 Amps Resistive Load. 1,000,000 Operations @ 120 VAC 5 Amps Resistive Load 2,000,000 Operations @ 120 VAC 2 Amps Resistive Load. 2000 V rms 1000 V rms 2000 VAC for 50 Microseconds (DC Models Only) Polycarbonate dust cover Square Base Plug-in 3/16" X .020" Quick Connect, P.C. Terminals Available 4 oz. 96 grams OUTLINE DIMENSIONS
Dimensions are Shown In Inches and Millimeter
The Class 388 Adjustable True Off Delay Relay combines a Solid State Timing circuit with a state of the art Magnetic Latching relay. This combination allows the relay to Pull-in when power is applied to the input. Timing starts when power is removed from the input and at the end of the preset timing period the relay will dropout.
WIRING DIAGRAM
Viewed from Pin End
1 4
2 5
3 6
DIELECTRIC STRENGTH Coil to Contacts: Across Open Contacts: Transient: Reverse Polarity Protection: MECHANICAL Enclosure: Mounting: Terminals: Weight:
7 A
8
9 B
+ INPUT Observe polarity on DC models
1.53 (38.8)
1 4 2 5 3 6
.312 (7.9)
2.90 Max. (73.8)
.625 (15.8)
7 A
8
9 B
1.40 (35.7)
PART NUMBERS AC OPERATED W388ACPSRX-29 W388ACPSRX-30 DC OPERATED W388CPSRX-35 W388CPSRX-36
NOMINAL INPUT VOLTAGE 120 VAC 120 VAC 24 VDC 24 VDC
TIMING RANGE
0.6 to 60 Seconds 0.1 to 10 Seconds 0.1 to 10 Seconds 0.6 to 60 Seconds
PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION.
SEE SECTION 10 FOR MATING SOCKETS
WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
PAGE 124
286/287 10 AMP SQUARE BASE TIME DELAY RELAY
SERIES 286 ON DELAY, 287 OFF DELAY
AC OR DC INPUT 1, 2 OR 3 POLE 10 AMP CONTACTS.
UL Recognized File No. E13224
SERIES
GENERAL SPECIFICATIONS SERIES 306 TIMER INPUT Coil Voltage Nominal Voltage: AC: 24 to 240, DC: 12 to 125 Minimum Oper. Voltage: AC - 85% of Nominal DC - 80% of Nominal Max. allowed voltage: 110% of nominal voltage CONTACTS Contact Material: Rating: Silver Cadmium Oxide. 10 Amps @ 120/240 VAC 10 Amps @ 28 VDC 1/3 Hp@ 120AC 1/2 Hp @ 240 VAC
The series 286 On Delay & 287 Off Delay Time Delay Relays have timing ranges from 0.1 to 300 Seconds. The 286 timer has up to three poles and the 287 timer has up to two poles. The 286 & 287 time delay relays are rated at 10 Amps, 120/240 Vac, 28 Vdc. SEE SECTION 10 FOR MATING SOCKETS
OPERATIONAL CHARACTERISTICS Repeatability: 3% @ 20C to 25C (AC +16 mS) Accuracy: Adjustable 10% Within temperature & voltage range. Fixed: 10% @ 25C Recycle Time: 100 mS up to 60 Seconds\ 150 mS, 60 to 300 Seconds INSULATION CHARACTERISTICS Dielectric Strength: All Mutually Insulated Points: Insulation Resistance: Transient Protection: False Contacting: Inverse polarity protection: ENVIRONMENTAL CAPABILITIES Ambient Temperature Rating: LIFE EXPECTANCY Mechanical: Electrical: MISCELLANEOUS Enclosure: Weight: 500 V rms across open contacts 1500 V rms between current carrying parts 1000 Megohms min. @ 500 VDC. 5 mS, 0 to 2000 V 20 uSec peak No false contacting is power is interupted during timing. DC coil are polarity protected. 10C to +70 C 10 Million Operations no load 100,000 Operations @ Rated Load. Clear Polycarbonate 5.0 oz approx. (142 g)
Struthers-Dunn
Typical Part Number
Series 286 - ON DELAY 287 - OFF DELAY Contact Arrangements XAX (SPDT) XBX (DPDT) XCX (3PDT) Mounting Options C Plug-in C1Note 1 Bracket Note 1 Top Stud CS1 C2 Side Tapped Hole CS2 Side Stud Timing Ranges 0.1 - 1.0 Sec - Code 001 0.2 - 2.0 Sec - Code 002 1.0 - 10 Sec - Code 010 3.0 - 30 Sec - Code 030 6.0 - 60 Sec - Code 060 18 - 180 Sec - Code 180 30 - 300 Sec - Code 300 Adjustment Options Adjustment Knob) - No Code Fixed Delay - Specify Fixed Time & Code F * Remote Adjustment - Code R ** Operating Voltage AC; 24, 48, 120, 240 (Add "A" ) DC; 12, 24, 48, 115-125 (Add "D")
286 XAX C 001 F 120A
EXTERNAL RESISTOR
WIRING DIAGRAM
Viewed from Terminal Side
EXTERNAL SWITCH 287 MODEL ONLY
EXTERNAL RESISTOR
1 4
2 5
3 6
1 4
2 5
3 6
7
+
8
INPUT
9 B
+
7 A
8
9 B
EXTERNAL - SWITCH 287 MODEL ONLY
A
INPUT 286XBX (DPDT) 287XBX (DPDT)
286XAX (SPDT) 287XAX (SPDT)
1 4
2 5
3 6
SEE SECTION 10 FOR MATING SOCKETS
-
7
+
8
INPUT ON DELAY 286XCX
9 B
A
(F * Models) - timing code does not apply. Specify single delay time requirement (R ** Models)- Available only for SPDT and DPDT models. External potentiometer required. Example of typical fixed time delay relay part number- 286XBXCS1-3.5F-120A (ON DELAY, DPDT, TOP STUD, 3.5 SEC FIXED, 120 VAC COIL INPUT)
Notes: Note 1: Bracket & top stud Not available with adjustable timing.
PAGE 125
WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
10 AMP SQUARE BASE TIME DELAY RELAY 286/287
OUTLINE DIMENSIONS
Dimensions shown are in INCHES and (millimeters)
SERIES
PLUG-IN, ADJUSTABLE TIMING
.625 (15.87)
SIDE STUD OR TAPPED HOLE, ADJUSTABLE TIMING
.125 (3.17) .625 (15.87)
Anti-rotation Tab Fits 0.177 dia. hole (No. 16 Drill)
CODE C
2.90 Max. (73.66)
CODE C2, CS2
.437 (11.1)
2.90 Max. (73.66)
6-32 Stud .281 typ. (7.14) 1.375 Max. (34.9) 1.50 Max. (38.1) .296 (7.54) 1.375Max. (34.9) 1.375Max. (34.9)
1.125 Max. (28.57)
1.50 Max. (38.1) 1.50 Max. .160 (38.1) (4.06)
PLUG-IN FIXED OR REMOTE TIMING
1.375Max. (34.9) 1.50 Max. (38.1)
BRACKET FIXED OR REMOTE TIMING CODE C
1.875 Max. (47.62)
CODE C1
.281 typ. (7.14) TERMINALS .187 X .020 (4.74 X .508) TERMINALS .187 X .020 (4.74 X .508)
SIDE STUD, FIXED OR REMOTE TIMING
.125 Max. (3.17) 1.375Max. (34.9) 1.50 Max. (38.1)
SIDE TAPPED HOLE, FIXED OR REMOTE TIMING
.125 Max. (3.17) Anti-rotation Tab Fits 0.177 dia. hole (No. 16 Drill) 1.375Max. (34.9) 1.50 Max. (38.1) Anti-rotation Tab Fits 0.177 dia. hole (No. 16 Drill)
CODE CS2
.437 (11.1)
CODE C2
.437 (11.1) 1.875 Max. (47.62)
1.875 Max. (47.62)
6-32 Stud 6-32 Tapped hole .296 (7.54) .281 typ. (7.14) 1.125 Max. (28.57) .281 typ. (7.14) 1.125 Max. (28.57)
6-32 STUD .125 Max. (3.17)
TOP STUD FIXED OR REMOTE TIMING
.375 (9.52) .281 (7.14) .437 (11.11) 1 4 1.875 Max. (47.62) 1.50 Max. (38.1) 7 A 1.375 Max. (34.9) ALL TERMINALS .187 X .020 (4.74 X .508) 2 5 8 3 6 9 B
CODE CS1
WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
21 21
6-32 tapped hole or 6-32 stud
.281 typ. (7.14)
1.90 Max. (48.26) 2.90 Max. (73.66) 2.50 (63.5) .281 typ. (7.14)
21 21
PAGE 126
SERIES
326/327
OCTAL 8 & 11 PIN TIME DELAY RELAY
SERIES 326 ON DELAY, & 327 OFF DELAY
AC OR DC INPUT 1, 2 OR 3 POLES 8 OR 11 PIN OCTAL BASES TIMING: FIXED, ADJUSTABLE OR REMOTE
GENERAL SPECIFICATIONS SERIES 306 TIMER INPUT Coil Voltage Nominal Voltage: Minimum Oper. Voltage: Max. allowed voltage: CONTACTS Contact Material: Rating:
UL Recognized File No. E13224
AC: 24 to 240, DC: 12 to 125 AC - 85% of Nominal DC - 80% of Nominal 110% of nominal voltage Silver Cadmium Oxide. 10 Amps @ 120/240 VAC 10 Amps @ 30 VDC 1/3 Hp@ 120AC 1/2 Hp @ 240 VAC
OPERATIONAL CHARACTERISTICS Repeatability: DC: 3% @ 20C. AC: 3% +16 mS @ 20C. Accuracy: Adjustable 10% Within temperature & voltage range. Switching time of output relay: 20 mS Min. waiting time before starting next cycle (reset time): 100 mS (for timing cycle up to 60 sec.) 150 mS (for timing cycle 60 to 300 sec) INSULATION CHARACTERISTICS Dielectric Strength: 500 V rms across open contacts All Mutually Insulated Points 1500 V rms between mutually insulated conductive elements. Insulation Resistance: 1000 Megohms min. @ 500 VDC. Transient Protection: 5 mS, 0 to 2000 V 20 uSec peak ENVIRONMENTAL CAPABILITIES Ambient Temperature Rating: LIFE EXPECTANCY Mechanical: Electrical: MISCELLANEOUS Enclosure: Weight: -10C to +70 C 10 Million Operations no load 100,000 Operations @ Rated Load. Clear Polycarbonate 5.0 oz approx. (142 g)
Struthers-Dunn
Typical Part Number
Series 326 - 0N DELAY 327 - OFF DELAY Contact Arrangements XAX (SPDT) XBX (DPDT) XCX (3PDT) Construction Style Octal style plug-in - Code 48P Non Standard Wiring - Code 48P-K Timing Ranges 0.1 - 1.0 Sec - Code 001 0.2 - 2.0 Sec - Code 002 1.0 - 10 Sec - Code 010 3.0 - 30 Sec - Code 030 6.0 - 60 Sec - Code 060 18 - 180 Sec - Code 180 30 - 300 Sec - Code 300 Adjustment Adjustment Knob) - No Code Fixed Delay - Specify Fixed Time & Code F * Remote Adjustment - Code R ** Operating Voltage AC; 24, 48, 120, 240 (Add "A" ) DC; 12, 24, 48, 115-125 (Add "D") (F * Models) - timing code does not apply. Specify single delay time requirement (R ** Models)- Available only for SPDT and DPDT models. External fixed or adjustable resistor required. Example of typical fixed time delay relay part number- 326XBX48P3.5F-120A (ON DELAY, DPDT, OCTAL PLUG, 3.5 SEC FIXED, 120 VAC POWER INPUT)
326 XAX 48P 001
F 120A
SEE SECTION 10 FOR MATING SOCKETS
PAGE 127
WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
OCTAL 8 & 11 PIN TIME DELAY RELAY
OUTLINE DIMENSIONS
Knob not on fixed or remote models
SERIES
326/327
.625 (15.87)
DIMENSION A ADJUSTABLE WITH KNOB STYLE 3.0 (76.2) FIXED OR REMOTE STYLE 326 Only 2.25 (57.15)
Dimensions shown are in INCHES and (millimeters)
A
4 3
5 6 7 4 3 2
5
6
7 8 9
10
8 PIN OCTAL BASE
2 1 8
1.375 (34.9)
11 PIN OCTAL BASE
1
11
1.375 (34.9)
1.375 (34.9)
WIRING DIAGRAMS
(VIEWED FROM PIN END) D D
MODELS WITH INTERNAL TIMING RESISTOR SLOW RELEASE SLOW OPERATE
4 3 2 5 6 7 1 8
w v w v
External Switch
5
w v
4 3 2
5 6 7
4 3 2
6
7 8 9 10
w v w v
5 4 3 2
6
7 9
w v
Jumper 8
10
+
-
+
1
8
|
+
1 11
|
+
1 11
||
| 326XAX48P
INPUT
INPUT
INPUT
INPUT
326XBX48P
326XCX48P
327XBX48P-K Non Standard
MODELS WITH EXTERNAL (REMOTE) TIMING RESISTOR SLOW OPERATE SLOW RELEASE D External D External D External Resistance Resistance Resistance D External
4 3 2 5 6 7 1 8
w v
Resistance
5 4 3 2
6
7 8 9 10
w v
4 3
5 6 7
w v
5 4 3 2
6
7 8 9 10
w v
+
-
+
1 11
-
+
2 1 8
-
INPUT
INPUT
External INPUT Switch
+
1 11
- External
Switch
INPUT
326XAX48P-R
326XBX48P-R
327XAX48P-R
327XBX48P-R
D External Resistor for remote timing adjustment on models 326 or 327 with code R. | This Diagram also applies to fixed time (code F) models. || Duplicates wiring of some similar relays made by others. D D Observe Polarity on DC input models
WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
PAGE 128
SERIES
236/237/238
12 PIN, 10 AMP, TIME DELAY RELAY
SERIES 236 ON DELAY, 237 OFF DELAY & 238 BATCH CONTROL INTERVAL (SEE NOTE 3)
AC OR DC INPUT DPDT OR DPDT WITH 1 N.O. CONTACT ON SERIES 236 & 238 12 PIN PLUG-IN WITH LOCKING CLIP TIMING: SCREWDRIVER ADJUSTABLE OR FIXED
GENERAL SPECIFICATIONS INPUT Nominal Voltage: Minimum Oper. Voltage: Max. allowed voltage: CONTACTS Contact Material: Rating: AC: 24 to 240, DC: 12 to 125 AC - 85% of Nominal DC - 80% of Nominal 110% of nominal voltage Silver Cadmium Oxide. 10 Amps @ 120 VAC res. 10 Amps @ 28 VDC
UL Recognized File No. E13224
The Series 236, 237 and 238 Time Delay Relay consists of a standard 219 industrial relay and a solid state timing module to provide delayed transfer of relay contacts after application of power or activation of control switch. The relay and timing module are enclosed in a flame resistant polycarbonate cover.
OPERATIONAL CHARACTERISTICS Repeatability: DC: 3%: @ 20C. AC: 3% +16 mS Accuracy: @ 20C. Adjustable: 10% Within temperature & voltage range. Fixed: 10% @ 25C Min. waiting time before starting next cycle (Reset Time): 100 mS (for timing cycle up to 60 sec. 150 mS for timing cycle 60 to 300 sec. INSULATION CHARACTERISTICS Dielectric Strength: Insulation Resistance: Transient Protection: False Contacting: Inverse polarity protection: 500 V rms across open contacts, 1500 V rms between output contacts and ground (Locking clip). (See note 4). 1000 Megohms min. @ 500 VDC. 5 mS, 0 to 2000 V 20 uSec peak No false contacting if power is interupted during timing. DC operated are polarity protected. but will not operate if polarity is reversed. - 10C to +70 C 10 Million Operations no load 100,000 Operations @ Rated Load. Clear Polycarbonate 8.6 oz approx. (244 g)
Struthers-Dunn
Typical Part Number
ENVIRONMENTAL CAPABILITIES Ambient Temperature Rating: LIFE EXPECTANCY Mechanical: Electrical: MISCELLANEOUS Enclosure: Weight:
236 ABX P 020
120A
Series 236 - ON DELAY 237 - OFF DELAY 238 - BATCH CONTROL INTERVAL Contact Arrangements ABX (DPDT & 1 N.O. Contact) 236 & 238 only). XBX (DPDT) Mounting Options P (Plug-in) Timing Ranges 0.2 - 12 Sec - Code 012** 0.2 - 20 Sec - Code 020 2.0 - 200 Sec - Code 200 Adjustment Options Adjustment Screw) - No Code Fixed Delay - Specify Fixed Time & Code F * Operating Voltage AC; 24, 48, 120, 240 (Add "A" ) DC; 12, 24, 48, 115-125 (Add "D")
Code 012**- 12 Second timing not available on 237 & 238 models. (F * Models) - timing code does not apply. Specify single delay time requirement. Example of typical fixed time delay relay part number- 236XBXP-3.5F-120A (ON DELAY, DPDT, 3.5 SEC FIXED, 120 VAC INPUT POWER). NOTES: 1. 236,237,238 - External resistor (to program time delay) or jumper (for built-in timing) must be connected to terminals 8 & 9. 2. 237 models require an external control switch between terminals 5 & 6. 3. 238 switches contacts when input power is applied and starts timing. Contacts switch back to original position at end of timing cycle. Power must be removed to reset timer. If input power is interupted during the timing cycle, timing ends immediately and the relay resets. 4. Dielectric withstanding voltage testing of the Control circuit may damage the solid state components.
SEE SECTION 10 FOR MATING SOCKETS
PAGE 129
WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
SERIES
12 PIN, 10 AMP, TIME DELAY RELAY
OUTLINE DIMENSIONS
Dimensions shown are in INCHES and (millimeters) Screwdriver adjust not on fixed models.
236/237/238
.313 (7.95)
3.75 (95.2)
| TIMING * RESISTANCE CHART 236 RANGE: O.2 TO 12 SEC 20K OHMS PER EA.3 SEC 100 K OHMS MAX. 236 RANGE: 0.2 TO 20 SEC 100K OHMS PER EA.7 SEC 500 K OHMS MAX 237/238 RANGE: 0.2 TO 20 SEC. 100K OHMS PER EA.6 SEC 500 K OHMS MAX. 236 RANGE: 2.0 TO 200 SEC 200K OHMS PER EA.60 SEC 1 MEG OHM MAX. 237/238 RANGE: 2.0 TO 200 SEC 200K OHMS PER EA.55 SEC. 1 MEG OHM MAX.
4.56 (115.8)
LOCKING CLIP
* USE RESISTOR RATED 1/4 WATT
1 12
2.625 (66.6)
6 7
1.468 (37.2)
OR MORE.
EXAMPLE WIRING DIAGRAMS
Viewed from Top of Relay
| Jumper or External Resistor | Jumper or External Resistor
12
TIMING MODULE
7-
12
7TIMING MODULE
INPUT
INPUT
76+
OFF DELAY
1
6+
1
6+
236ABXP
ON DELAY DOUBLE POLE DOUBLE THROW WITH NORMALLY OPEN CONTACT
237XBXP
External control switch DOUBLE POLE DOUBLE THROW
| If the jumper wire shown in each diagram is replaced by a resistor, delay time will be added to that which is produced by an internal fixed resistor on fixed time models (code F) or any setting on screwdriver adjustable models. See timing resistance chart above. Relay will not operate without a jumper or resistor. Also see note 1.
| Jumper or External Resistor
12
TIMING MODULE
1
DOUBLE POLE DOUBLE THROW
238XBXP
WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
INPUT
BATCH CONTROL INTERVAL (SEE NOTE 3)
PAGE 130
SERIES
246 & 247 INDUSTRIAL 10 AMP, ON-DELAY & OFF DELAY TIMER
SERIES 246 & 247
PLUG-IN WITH SELF LOCKING CLIP
UL Recognized File No. 13224 Listed when used with Type 29390 Socket
3% REPEATABILITY
OFF DELAY FUNCTION
1
EXT. TRIGGER
Dimensions shown are in INCHES and (millimeters) .678 (17.2)
6
TIME MOD
247XCXP
12 1
EXT. TRIGGER
7 6
TIME MOD
R
247XBXP
3.75 (95.2)
R
12
7
Series 246 CSA Certified ON DELAY FUNCTION
1 6
TIME MOD
4.56 (115.8)
The series 246 & 247 Time Delay Relays are a ON-Delay or Off Delay Function times, with timing ranges from 0.1 to 300 Seconds. The 246 Timer comes in either 2 - 4 poles, and the 247 comes in 2 & 3 Pole models. Both timers incorporate a class 219 relay along with a Solid State timing module. Both timers have a large choice of options and switch up to 30 amp loads.
CONTACT LOAD SPECIFICATIONS Make Carry Resistive Inductive Voltage
24 VDC 120 VAC 240 VAC 28 VDC 125 VDC 30A 30A 30A 30A 30A 10A 10A 10A 10A 10A 10A 10A 5A 10A 0.5A 10A 3A 1A 3A 0.1A
246BBXP
12 1
7 6
TIME MOD
246XBXP
1 12
2.625 (66.6)
6 7
1.468 (37.2)
12 1
7 6
TIME MOD
246ABAP
12
7
For Versions with suffix "69" Permant Magnet Blowouts
125 VDC (SM) 125 VDC (DM) 250 VDC (SM) 250 VDC (DM) 30A 30A 30A 30A 10A 10A 10A 10A 1.5A 4A 0.5A 1.5A 0.5A 1.5A 150mA 0.5A
GENERAL SPECIFICATIONS SERIES 246 & 247 TIMER INPUT Coil Voltage Minimum Operate Voltage: Max. allowed voltage:
Struthers-Dunn
Typical Part Number
AC - 85% of Nominal DC - 80% of Nominal 110% of nominal voltage Silver Cadmium Oxide. - Gold Diffused 3% @ 25C (AC +16 mS) Adjustable 10% Within temperature & voltage range. 100 mS up to 60 Sec., 150 mS 60 to 300 Sec. No false contacting if power is interrupted during timing cycle. DC inputs 500 V rms across open contacts 1500 V rms between current carrying parts & Parts to Ground. 5 mS 0 to 2000V, 20 uSec peak 1000 M min. @ 500 VDC AC: -10C to +45C @ Rated Operation. DC: -10C to +70 C 10 Million Operations no load 100,000 Operations @ Rated Load. 500,000 @ 1/2 Rated Load. Clear polycarbonate 8 oz. (227 g)
247 XBX P L - 010
- 120A
Series 246 - On Delay, Plug-in 2-4 Pole 247 - Off Delay, Plug-in, 2 & 3 Pole Contact Arrangements XBX (2 Form "C") XCX (3 Form "C") ABA (1 Form A & 2 Form C & 1 Form B). BBX (2 Form A & 2 Form C) 246 Only. Standard Features Plug-in With Polycarbonate Cover - Code P Options Indicator Lamp- Code L Manual Actuator - Code M Bifurcated Contacts (5 Amps max) - Code 33 Permanent Magnet, Blowout Code 69 Timing Ranges 0.1 - 1.0 Sec - Code 001 0.2 - 2.0 Sec - Code 002 1.0 - 10 Sec - Code 010 3.0 - 30 Sec - Code 030 6.0 - 60 Sec - Code 060 18 - 180 Sec - Code 180 30 - 300 Sec - Code 300 Adjustment Adjustment Knob) - No Code Fixed - Timing Code does not apply. Ex. 3F = 3 Sec Fixed) Code F Remote Adj. (Ext Pot Required) - Code R Operating Voltage AC; 24, 48, 120, 240 (Add "A" ) DC; 12, 24, 48, 110-125 (Add "D")
CONTACTS Contact Material: OPERATIONAL CHARACTERISTICS Repeatability: Accuracy: Recycle Time: False Contacting: Polarity Protection: INSULATION CHARACTERISTICS Dielectric Strength: All Mutually Insulated Points: Transient Protection: Insulation Resistance: ENVIRONMENTAL CAPABILITIES Ambient Temperature Rating: LIFE EXPECTANCY Mechanical: Electrical: MISCELLANEOUS Enclosure: Weight:
SEE SECTION 10 FOR MATING SOCKETS
PAGE 131
WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
ADJUSTABLE CURRENT SENSING RELAY
SPECIFICATIONS CLASS 235 CURRENT SENSOR CURRENT SENSING: Sense Current Range: Repeatability: 1.5 to 15 Amperes 2% at constant Voltage & Temperature 10% over Voltage & Temperature Range. 15 mA (1.7 VA) Input Current: Current Sensor Resistance: 5 Milliohms Temperature Range Operate: - 10C to + 55C Temperature Range Storage: - 40C to + 85C
CLASS
235
CLASS 235 CURRENT SENSOR
2 % REPEATABILITY SPDT, 10 AMP CONTACTS FIELD ADJUSTABLE CURRENT SETTINGS.
Ul Recognized File No. 62636
CONTACTS Contact Combinations: Contact Rating Transient: LIFE EXPECTANCY; Electrical Mechanical: DIELECTRIC STRENGTH Coil to Contacts: Across Open Contacts: MECHANICAL Terminals: Mounting: Mounting Bracket: Enclosure: Weight:
SPDT (1 Form C) 10 Amps @ 120 VAC, 6 Amps @ 28 VDC. 2000 V rms for 5 Microseconds
200,000 Operations @ Rated Load 5,000,000 Operations @ No Load
2500 V rms 500 V rms
The Class 235 Current Sensing Relay combines a Solid State Sensor with a SPDT, 10 Amp relay. The Sensor is field adjustable for detecting AC Current levels in equipment. The sensor is non-latching and has no time delay.
Choice of 1/4" or 3/16" Quick Connect terminals. 6-32 Tapped Hole & anti rotation Tab or Plug-in with 3/16" terminals. Optional. Polycarbonate dust cover. 4 oz. (113 g) approx.
OUTLINE DIMENSIONS
Dimensions are Shown In Inches and (Millimeters)
WIRING DIAGRAM
1 4
SUPPLY VOLTAGE
1.53 (38.8)
1 4 2 5 3 6
.312 (7.9)
2.90 Max. (73.8)
.625 (15.8)
2 5
3 6
7 A
8
9
LOAD
7 A
8
9 B
1.40 (35.7)
B
INPUT
Continuous Voltage must be supplied to Input. VIEWED FROM TERMINAL SIDE
1.31 (33.3) .875 (22.2)
ANTI-ROTATION TAB
SEE SECTION 10 FOR MATING SOCKETS
6-32 TAPPED HOLE (1/4" Terminal Style)
PART NUMBERS W235ACX-2 W235ACX-3
NOMINAL INPUT VOLTAGE 120 VAC 120 VAC
CURRENT RANGE
TERMINAL SIZE
1.5 to 15 Amps 1/4" (.250) 1.5 to 15 Amps 3/16" (.187)
PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION.
NOTE: 3/16" (.187) TERMINALS ARE SOCKET MOUNTABLE. 1/4" (.250) TERMINALS, NO SOCKET AVAILABLE FOR THIS STYLE.
WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
PAGE 132
SERIES
349
OVER/UNDER VOLTAGE SENSING, 10 AMP, 2-4 POLE
SERIES 349
FREQUENCY 50 to 400 Hz PULL-IN ADJUSTABLE BETWEEN 85 to 135 VAC 10 AMP CONTACTS
OUTLINE DIMENSIONS
Dimensions shown are in INCHES and (millimeters) Differential 4.0 volts 1 Volt nonadjustable .313 (7.95)
1
6
12
7
349 ABXP & XBXP Style the Differential Adjustment is Externally Adjustable from 3 to 14 Volts. CONTACT LOAD SPECIFICATIONS Make Carry Resistive Inductive Voltage
24 VDC 120 VAC 240 VAC 28 VDC 125 VDC 30A 30A 30A 30A 30A 10A 10A 10A 10A 10A 10A 10A 5A 10A 0.5A 10A 3A 1A 3A 0.1A
SINGLE PHASE -349ABXP A
1
SENSING MODULE
B
C
N RESISTOR
6 1 12 6 7
2.625 (66.6) 1.468 (37.2)
12
7
THREE PHASE -349XBXP
For Versions with suffix "69" Permanent Magnet Blowouts
125 VDC (SM) 125 VDC (DM) 250 VDC (SM) 250 VDC (DM) 30A 30A 30A 30A 10A 10A 10A 10A 1.5A 4A 0.5A 1.5A 0.5A 1.5A 150mA 0.5A
INPUT
SENSING MODULE
The Series 349 Under/Over Voltage Sensing Relay incorporates a Series 219 relay and an Electronic Module. Pull-in Voltage is adjustable between 85 and 135 VAC for frequencies from 50 to 400 Hz. Models available for Single and Three Phase sensing with differential (between pull-in and Dropout) Adjustable from 2 to 14 Volts by external fixed or adjustable resistor. Single Phase relays are also available with standard 3 volt fixed differential and other fixed values up to 14 volts, on special order.
12
7
INPUT
SENSING MODULE
SINGLE PHASE -349BBXP RESISTOR
1 6
3.75 (95.2)
4.56 (115.8)
Struthers-Dunn
Typical Part Number 349 BBX Series 349 Sensor -Plug-in, Over/Under Voltage Relay, 10A, 2 -4 poles
P L33- 85-135A
GENERAL SPECIFICATIONS SERIES 349 SENSOR INPUT Module Voltage: AC Current Drain: CONTACTS Contact Material: Adjustment 85 to 135 VAC, 50 to 400 Hz De-energized -15 mA, Energized - 50 mA Silver Cadmium Oxide. - Gold Diffused Contact Arrangement & Function BBX - 2 Form A & 2 Form C, (Single Phase) 4V 1V Fixed. ABX - 1 Form A & 2 Form C, (Single Phase) Ext. Adjustment, 3 to 14V XBX - 2 Form C, (3 Phase) External Adjustment, 3 to 14V Standard Features Plug-in With Polycarbonate Cover - Code P Options Indicator Lamp- Code L Manual Actuator - Code M Bifurcated Contacts (5 Amps max) - Code 33 Permanent Magnet, Blowout Code 69 Operating Voltage AC; 85 to 135 (Add "A" ) DC; Consult Factory Note: For non-Standard Differential Consult Factory
OPERATIONAL CHARACTERISTICS 25 Milliseconds Operate time: 25 Milliseconds Release Time: INSULATION CHARACTERISTICS Dielectric Strength Across Open Contacts: All Mutually Insulated Points: Insulation Resistance ENVIRONMENTAL CAPABILITIES Ambient Temperature Rating: LIFE EXPECTANCY Mechanical: Electrical: MISCELLANEOUS Enclosure: Weight:
500 V rms 1500 V rms 1000 Megohms min. @ 500VDC. -10C to +60C @ Rated Operation. 20 Million Operations no load 100,000 Operations @ Rated Load. 500,000 @ 1/2 Rated Load. Clear polycarbonate 10 oz. (284 g)
SEE SECTION 10 FOR MATING SOCKETS
PAGE 133
WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
ADJUSTABLE VOLTAGE SENSING RELAY
The Class 236 Voltage Sensing Relay combines a Solid State Sensor with a SPDT, 13 Amp or DPDT 10 Amp relay. The Sensor is field adjustable for Pull-in & Dropout . The 236 can be used either as a over or under voltage detecting relay. The sensor is non-latching and has no time delay. Applications: Brownout protection, warning of under voltage conditions and Over voltage protection. Prevents equipment burnout.
CLASS
236
CLASS 236 VOLTAGE SENSOR
Ul Recognized File No. 62636
SPECIFICATIONS CLASS 236 CURRENT SENSOR VOLTAGE SENSING: Nominal Input: 120,240,480 VAC 50/60Hz, 24VAC, 24 VDC. Other AC & DC Voltages Available. Pull-in 75% to 115% of Nominal Voltage. Adjustment Range: Dropout 75% to 95% of Pickup setting. 1% @ constant Voltage & Temperature Repeatability: 15 mA (1.7 VA) Input Current: Relay "Off" 2 mA max. Relay "On" 22 mA max. @ 120AC (2.7 VA) Current Sensor Resistance: 12 mA 240AC max. (2.9VA), 7 mA max. 480 AC (3.41 VA) Temperature Range Operate: - 30C to + 55C Temperature Range Storage: - 40C to + 85C
1 % REPEATABILITY SPDT, 13 AMP CONTACTS FIELD ADJUSTABLE
CONTACTS Contact Combinations: Contact Rating
Contact Life Electrical: Contact Life Mechanical: Transient: Noise Immunity: DIELECTRIC STRENGTH Breakdown: Coil to Contacts: Across Open Contacts: MECHANICAL Terminals: Enclosure: Power "ON" Indicator: Weight:
SPDT (1 Form C), DPDT (2 Form "C") SPST: 13 Amps @ 240 VAC, 28 VDC Res. 1/3 HP @ 120 VAC, 1/2 HP @ 240/480 AC, 3 AMPS @ 480 VAC, NEMA B300 Pilot Duty DPDT: 10 AMPS @ 240 VAC/28 VDC Res. 1/3Hp @ 120 VAC, 1/2 Hp 240 VAC NEMA B300 Pilot Duty. SPDT: 100,000 Operations @ 13 Amps, 240AC Res. DPDT: 100,000 Operations @ 10 Amps, 240AC Res. SPDT:5,000,000 Operations DPDT: 50,000,000 Operations. UL 508 Surge 5000 V for 50 microseconds NEMA ICS2-230, 2500 VAC
1 % REPEATABILITY DPDT, 10 AMP CONTACTS FIELD ADJUSTABLE
UL 508 Surge 5KV 1.2 x 50 Microseconds. 2500 V rms 1000 V rms
3/16" (.187) Quick Connect terminals. or 8 Pin Octal base Polycarbonate dust cover. L.E.D. ( Green) 4 oz. 124.4 g, 5 oz 155.5g (8 pin octal)
SEE SECTION 10 FOR MATING SOCKETS
WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
PAGE 134
CLASS
236
ADJUSTABLE VOLTAGE SENSING RELAY
OUTLINE DIMENSIONS
Dimensions are Shown In Inches and (Millimeters)
WIRING DIAGRAMS
VIEWED FROM PIN END
1.53 (38.8)
1 4 2 5 3 6
.312 (7.9)
2.90 Max. (73.8)
L.E.D
1 4
2
3 6
5
7 7 A
INPUT
8
9 B
1.40 (35.7)
FIGURE "B"
8
9 A B
Continuous Voltage must be supplied to Input.
L.E.D
Dropout
Pull-in
SQUARE BASE
L.E.D
Screw Driver Adjustable with Graduated scale.
OUTLINE DIMENSIONS
Dimensions are Shown In Inches and (Millimeters)
.562 (14.2)
L.E.D
WIRING DIAGRAMS
VIEWED FROM PIN END
FIGURE "A"
w v w v
2.93 (74.4)
4 3 2 1
5 6 7 8
+
INPUT
2.37 (60.3)
6 5 4 3 2 7 8 1
8 PIN OCTAL
Continuous Voltage must be supplied to Input.
1.75 (44.4)
PART NUMBERS W236ACX-1 W236ACX-2 W236ACX-4 W236ACPX-1 W236ACPX-4 W236CPX-1
FIG. B B B A A A
VOLTAGE DROP-OUT RANGE 120 VAC 90 to 138 VAC 75% to 95% 208/220 240 VAC 180 to 276 VAC of Pickup Voltage 480 VAC 360 to 552 VAC Setting 120 VAC 24 VAC 24 VDC 92 to 140 VAC 90 to 138 VAC 20 to 30 VAC 18 to 28VAC 20 to 30 VDC 18 to 28 VDC
NOMINAL INPUT VOLTAGE
VOLTAGE PULL-IN RANGE
CROSS REFERENCE TO POTTER & BRUMFIELD CSJ-38-70010 CSJ-38-30010 CSL-38-30010
PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION.
PAGE 135
WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
SECTION
6
6
POWER RELAYS AND CONTACTORS 15 TO 200 AMPERES Page 136
Magnecraft
Struthers-Dunn
POWER RELAYS & CONTACTORS
RELAY SERIES 199 425 88UKD 415
QUALIFIED
FEATURES
PANEL MOUNT, OPEN STYLE CONSTRUCTION MULTI CONTACT CONFIGURATIONS UP TO 50 AMPS SWITCHING. MAGNETIC BLOWOUT FOR DC SWITCHING CLASS "B" INSULATION SYSTEM SCREW & BOX TERMINALS
COMPACT OPEN STYLE PANEL MOUNT OPEN STYLE CONSTRUCTION RELAY WITH 6-32 TAPPED HOLE & ANTI-ROTATION 3PDT CONTACT TAB FOR PANEL MOUNT. CONFIGURATIONS UP TO 30 AMP SWITCH- SWITCHES UP TO 3O ING AMPS SCREW TERMINALS 1/4" SPADE LUG TERMIINSULATED ARMATURE NALS TO 600V AVAILABLE DOUBLE MAKE CONTACTS
PANEL MOUNT, COMPACT SIZE, OPEN STYLE CONSTRUCTION. MULTI CONTACT CONFIGURATIONS. SCREW TERMINALS. OPTIONAL HIGH VOLTAGE AND HIGH INRUSH CONTACTS, Q.C. TERMINALS, MAGNET BLOWOUT. SPECIAL LOW POWER COILS AVAILABLE. SEE CATALOG PAGE 15 AMPS @ 120VAC 1/2HP 10 AMPS @ 240VAC 1HP 15 AMPS @ 30VDC
CONTACT DATA
CONTACT CONFIGURATION: MAXIMUM ALLOWABLE CONTACT LOAD:
SEE CATALOG PAGE 30 AMPS UP TO 300 VAC, 28 VDC, (STD.) BOX TERMINAL SPST-DM -UP TO 50A. WITH MAGNETIC BLOWOUT UP TO 20AMP DC SILVER CADMIUM OXIDE, 50 MILLIOHMS (INITIAL)
3PDT 25 AMP @120-240VAC 17AMP @ 277VAC 10AMP @ 600VAC 30AMP @ 30VDC
SPST-N.0. (DM) 30 AMPS @ 300VAC/28VDC 5 AMPS 600VAC
CONTACT MATERIAL: CONTACT RESISTANCE:
SILVER CADMIUM OXIDE 50 MILLIOHMS (INITIAL)
SILVER ALLOY GOLD FLASHED 50 MILLIOHMS (INITIAL)
SILVER CADMIUM OXIDE 50 MILLIOHMS (INITIAL)
INSULATION CHARACTERISTICS
DIELECTRIC STRENGTH 2200 V rms 24, 120 & 240 VAC 6, 12, 24, 110 VDC 10 VA 2.0 WATTS 2500 V rms 6 to 480 VAC 6 to 220 VDC 11 VA 4.0 WATTS 3000 V rms 24, 120 & 240 VAC 12, 24 & 110 VDC 3 VA 1.5 WATTS 1500 V rms 6 to 240 VAC 6 to 125 VDC (Use power resistor for 250VDC) 6VA 3.5 WATTS
COIL DATA
AC - VOLTAGE: DC - VOLTAGE: POWER VA,: (VAC) WATTS,: (VDC)
GENERAL DATA
AMBIENT TEMPERATURE OPERATIONAL: STORAGE: TIMING VALUES OPERATE: RELEASE: LIFE MECHANICAL: ELECTRICAL: - 30 C to + 50 C (AC.) - 30 C to + 60 C (DC) - 30 C to + 100 C 40 MILLISECONDS 35 MILLISECONDS - 55 C to + 45 C (AC) - 55 C to + 80 C (DC) 30 MILLISECONDS 15 MILLISECONDS 5 MILLION OPERATIONS 100,000 OPERATIONS D W L - 10 C to + 50 C (AC) - 10 C to + 60 C (DC) - 45 C to + 55 C - 45 C to + 55 C 25 MILLISECONDS 10 MILLISECONDS
5 MILLION OPERATIONS 100,000 OPERATIONS D W L 2.53 X 2.50 X 2.43-3.12
10 MILLION OPERATIONS 100,000 OPERATIONS DW L 2.30 X 2.50 X 3.24
AC- 50M, - DC-100M OPER'S. 200,000 OPERATIONS D W L
DIMENSIONS APPROVALS PAGE NUMBER PAGE 137
.1.40 X 1.25 X 1.93
1.75 X 1.87 X 2.75
PAGE 140 THRU 146
PAGE 147
PAGE 148
PAGE 149, 150
WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
Magnecraft
Struthers-Dunn
CONTACTORS
275 575 101 102 103
2 COIL, COMPACT MOTOR REVERSING CONTACTOR. 1/4" DUAL Q.C. TERMINALS WITH UP TO 4 OPTIONAL AUXILIARY SWITCHES. ENCAPSULATED COIL USED FOR AC OR DC MODELS MECHANICAL INTERLOCK, CENTER OFF WHEN BOTH COILS NOT ENERGIZED. 6 POLE-DM (3 PER COIL) 15 AMPS @120VAC/1HP 10AMPS @ 240VAC/1.5HP 5AMPS @ 480/600/3HP 15AMPS @ 30VDC 5AMPS @ 125VDC 1AMP @ 250VDC SILVER CADMIUM OXIDE 100 MILLIOHMS (INITIAL)
2 COIL, MOTOR REVERSING CONTACTOR
HEAVY DUTY DC SOLENOID HEAVY DUTY DC SOLENOID STYLE CONTACTOR. STYLE CONTACTOR. CHOICE OF CONTACT CONFIGURATIONS RATED UP TO 100 AMPS CONTINUOUS CONTACTS ENCLOSED WITH MOLDED PLASTIC COVER. AC COILS AVAILABLE
HEAVY DUTY DC SOLENOID STYLE CONTACTOR. CHOICE OF CONTACT CONFIGURATIONS RATED UP TO 200 AMPS CONTINUOUS CONTACTS ENCLOSED WITH MOLDED PLASTIC COVER. AC COILS AVAILABLE
MECHANICAL INTERLOCK CHOICE OF CONTACT CONFIGURATIONS COILS RATED UP TO 50 AMPS SCREW TERMINALS WITH CONTINUOUS OPTIONAL 5A AUXILIARY CONTACTS ENCLOSED SWITCHES AVAILABLE. WITH MOLDED PLASTIC COVER. RATED UP TO 7.5 HP AC COILS AVAILABLE
6 POLE-DM (3 PER COIL) 30 AMPS @120 VAC, 1.5HP 30 AMPS @240VAC, 3HP 15 AMPS @480 VAC, 7.5HP 15 AMPS @600 VAC, 7.5HP 15 AMPS @ 115VDC 2 AMPS @ 230 VDC SILVER CADMIUM OXIDE 100 MILLIOHMS (INITIAL)
SEE CATALOG PAGE 50 AMPS @ 120/240VAC, 30 VDC
SEE CATALOG PAGE 100 AMPS @ 120/240VAC, 30 VDC
SEE CATALOG PAGE 200 AMPS @ 120/240VAC, 30 VDC
SILVER CADMIUM OXIDE 50 MILLIOHMS (INITIAL)
SILVER CADMIUM OXIDE 50 MILLIOHMS (INITIAL)
SILVER CADMIUM OXIDE 50 MILLIOHMS (INITIAL)
2500 V rms 12 to 240 VAC 12 to 120 VDC 16.7 VA 4.9 WATTS
2500 V rms 24 to 550VAC 12 to 240 VDC 22 VA 10 WATTS
1500 V rms 12, 28, 48 VDC 9 WATTS
1500 V rms 12, 28, 48 VDC 11.6 WATTS
1500 V rms 12, 28, 48 VDC 14 WATTS
- 45 C to + 50 C (AC) - 45 C to + 70 C (DC) 50 MILLISECONDS 30 MILLISECONDS
- 40 C to + 50 C (AC) - 40 C to + 50 C (DC) 60 MILLISECONDS 30 MILLISECONDS
- 45 C to + 65 C (DC) 60 MILLISECONDS 30 MILLISECONDS
- 45 C to + 65 C (DC) 60 MILLISECONDS 30 MILLISECONDS
- 45 C to + 65 C (DC) 60 MILLISECONDS 30 MILLISECONDS
500,000 OPERATIONS 100,000 OPERATIONS D W L
500,000 OPERATIONS 100,000 OPERATIONS D W L
500,000 OPERATIONS 100,000 OPERATIONS D W L
500,000 OPERATIONS 100,000 OPERATIONS D W L
500,000 OPERATIONS 100,000 OPERATIONS D W L
2.75 X 2.985 6 X 3.62
3.00 X 5.25 X 4.43
1.84 X 2.34 X 2.50
2.09 X 3.12 X 3.00
2.65 X 4.25 X 3.00
PAGE 151, 152
PAGES 153, 154
PAGES 155, 156
PAGES 155, 156
PAGES 155, 156 PAGE 138
WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
Magnecraft
Struthers-Dunn
POWER , GFI AND MDR RELAYS
RELAY SERIES 214 (GFI) MDR 102, 103
FEATURES
SMALL OPEN STYLE GROUND FAULT INTERRUPT RELAY. MAX. OVER LOAD 120 AMPS @ 120VAC PIERCED SOLDER LUG TERMINALS WITH #17 AWG SILICONE WIRE MOUNTING WITH 6-32 TAPPED HOLE & ANTIROTATION TAB
MERCURY DISPLACEMENT RELAY (MDR) UP TO 3 POLES, NO OR NC & COMBINATIONS OF NO & NC ENCAPSULATED COIL.. UP TO 100 AMPS SWITCHING LOW CONTACT RESISTANCE PANEL MOUNTED VERTICAL 15
HEAVY DUTY DC SOLENOID STYLE LIGHTING CONTACTOR, MOUNTS TO WATT HOUR METER ENCLOSURE. DPST-NO-DM CONTACT CONFIGURATION. RATED UP TO 50 & 100 AMPS CONTINUOUS DUTY. CONTACTS ENCLOSED IN MOLDED PLASTIC COVER. DC COILS AND AC FULL WAVE RECTIFIED COILS. DPST-NO-DM 50 & 100 AMPS @ 120/240VAC, 30 VDC
CONTACT DATA
CONTACT CONFIGURATION: DPDT (2 FORM C) 20 AMPS @ 120/240VAC 20 AMPS @ 30 VDC 120AMPS @ 120VAC (10 CYCLES) 1 to 3PST-NO or NC 35 TO 100 AMPS @ 120-480VAC. 25-50 AMPS @ 600VAC 100 AMPS, 24-48 VDC 80 AMPS, 120VDC MERCURY 2 MILLIOHMS MAXIMUM ALLOWABLE CONTACT LOAD:
CONTACT CONTACT
MATERIAL: RESISTANCE:
SILVER, CADMIUM OXIDE 50 MILLIOHMS (INITIAL)
SILVER CADMIUM OXIDE 50 MILLIOHMS (INITIAL)
INSULATION CHARACTERISTICS
DIELECTRIC STRENGTH: 2000 V rms 6, 12, 24, 120 VAC 6, 12, 24, 110-125 VDC 2650 V rms 120 & 240 VAC 24 VDC 33 VA 9 WATTS 1500 V rms 12 to 240 VAC 6 to 220 VDC 20 WATTS
COIL DATA
AC - VOLTAGE: DC - VOLTAGE: POWER VA, (VAC): WATTS, (VDC):
GENERAL DATA
AMBIENT TEMPERATURE OPERATIONAL: STORAGE: TIMING VALUES OPERATE: RELEASE: LIFE MECHANICAL: ELECTRICAL: - 45 C to + 65 C - 35 C to + 60 C - 45 C to + 65 C (DC) 15 MILLISECONDS 15 MILLISECONDS 50 MILLISECONDS 100 MILLISECONDS 60 MILLISECONDS 30 MILLISECONDS
10 MILLION OPERATIONS 100,000 OPERATIONS D W L
5 MILLION OPERATIONS 100,000 OPERATIONS D W L
500,000 OPERATIONS 100,000 OPERATIONS D W L
DIMENSIONS APPROVALS
1.37 X 1.00 X 2.10
3.36 X 3.75 X 5.06
3.0 X 6.0 X 6.0
GENERAL SPECIFICATIONS & APPLICATION DATA:
PAGE 158, 159 PAGE 160 THRU 164 PAGES 165
PAGE NUMBER PAGE 139
PAGE 157
WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
OPEN STYLE 30 AMP POWER RELAY
CLASS 199 SPDT
UL Listed File No. E43641 COMPLIES WITH REQUIREMENTS OF IEC STANDARDS 947-4-1 AND 947-5-1 LOW VOLTAGE DIRECTIVE
CLASS
199
*
30 AMP - 1-1/2 Hp CLASS "B" COIL INSULATION SYSTEM
IEC = INTERNATIONAL * ELECTROTECHNICAL COMMISSION
OUTLINE DIMENSIONS
Dimensions shown in Inch & (Millimeters)
2.18 Max. (55.37)
UP
.375 (9.5)
VERTICAL MOUNTING RECOMMENDED WITH CONTACTS UP
1.62 41.14 2.43 Max. (61.7)
2.50 (63.5)
1.87 (47.5) 0.187 Dia. (2 Places)
SPECIFICATIONS CLASS 199 COIL Pull-in Voltage: Dropout Voltage: Coil Resistance: Max. Coil Dissipation: CONTACTS Contact Combination: Contact Rating 80% DC Coils, 85% AC coils of nominal voltage or Less @ 25C 10% of Nominal Voltage or More @ 25C 10% @ 25C DC Coils-4 Watts Max. Continuous. SPDT 30 Amps up to 300VAC, 50/60Hz 5 Amps @ 480/600 VAC, 50/60HZ 0.75pF Inductive Load. 1-1/2 HP Motor Load @ 120 thru 600 VAC, 50/60 Hz. 30 Amps @ 28 VDC Resistive Load NEMA A 600 Pilot Duty 50/60Hz Silver Cadmium Oxide, Gold Flashed. 5/16" Diameter Standard. 40 Milliseconds Max. @ Nominal V 30 Milliseconds Max. @ Nominal V 1500 V rms 2200 V rms (AC) -30C to +50C, (DC) -30C +60C -30C to +100C 100,000 Operations 5,000,000 Operations 6-32 Binder Head Screws 8-32 Binder Head Screws Molded Phenolic, UL Recognized (QMFZ2) 8 oz. - 227 Grams approx. (SPDT) PART NUMBERS COIL Measured @ 25C NOMINAL NOMINAL NOMINAL RESISPOWER INPUT TANCE VOLTAGE (OHMS) 70 290 10 VA
* RELEVANT IEC CONTACT UTILIZATION CATEGORIES
AC-1, AC-3, DC-1, AC-15
SEE SECTION 11, FOR RELEVANT UTILIZATION CATEGORIES
Contact Material: TIMING Operate time: Release Time: DIELECTRIC STRENGTH Between Open Contacts: Mutually Insulated Conductive elements: TEMPERATURE Operating Range: Non-Operating Storage range: LIFE Electrical (Rated Load): Mechanical (No Load): MISCELLANEOUS Coil Terminals: Contact Terminals: Base Material: Weight:
CROSS REFERENCE POTTER & BRUMFIELD
W199AX-4
AC OPERATED (SPDT) 120 VAC DC OPERATED (SPDT) 12 VDC W199X-2 24 VDC W199X-3
PRD5AGO-120
2.0 W 2.0 W
PRD5DGO-12 PRD5DGO-24
PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION.
AUXILIARY CONTACTS AND OTHER COIL VOLTAGES ARE AVAILABLE ON SPECIAL ORDER. CONTACT FACTORY FOR SPECIAL REQUIREMENTS.
WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
PAGE 140
CLASS
199
OPEN STYLE 30 AMP POWER RELAY
CLASS 199 DPDT
30 AMP - 1-1/2 Hp CLASS "B" COIL INSULATION SYSTEM
UL Listed File No. E43641 COMPLIES WITH REQUIREMENTS OF IEC STANDARDS 947-4-1 AND 947-5-1 LOW VOLTAGE DIRECTIVE
*
IEC = INTERNATIONAL * ELECTROTECHNICAL COMMISSION
OUTLINE DIMENSIONS
Dimensions shown in Inch & (Millimeters)
2.31 Max. (58.67)
UP
1.87 (47.5) 0.187 Dia. (2 Places)
.375 (9.5)
2.50 (63.5)
1.62 3.12 (41.1) (79.2)
VERTICAL MOUNTING RECOMMENDED WITH CONTACTS UP
* RELEVANT IEC CONTACT UTILIZATION CATEGORIES
AC-1, AC-3, DC-1, AC-15
SEE SECTION 11, FOR RELEVANT UTILIZATION CATEGORIES
SPECIFICATIONS CLASS 199 COIL Pull-in Voltage: Dropout Voltage: Coil Resistance: Max. Coil Dissipation: 80% DC Coils, 85% AC coils of nominal voltage or Less @ 25C 10% of Nominal Voltage or More @ 25C 10% @ 25C DC Coils-4 Watts Max. Continuous.
PART NUMBERS
COIL Measured @ 25C CROSS NOMINAL NOMINAL NOMINAL REFERENCE RESIS- POWER INPUT POTTER & TANCE VOLTAGE BRUMFIELD (OHMS) 10 VA 10 VA 10 VA PRD11AGO-24 PRD11AGO-120 PRD11AGO-240
AC OPERATED (DPDT) 24 VAC W199AX-13 120 VAC W199AX-14 240 VAC, 60 Hz W199AX-15 220 VAC, 50 Hz DC OPERATED (DPDT) W199X-11 W199X-12 W199X-13 W199X-14 6 VDC 12 VDC 24 VDC 110 VDC
CONTACTS DPDT Contact Combinations: Contact Rating each Pole: 30 Amps up to 300VAC, 50/60Hz 5 Amps @ 480/600 VAC 50/60Hz, 0.75pF Inductive Load. 1-1/2 HP Motor Load (each Pole) @ 120 thru 600 VAC, 50/60 Hz. 2 HP Motor Load @ 200 thru 600 VAC, 50/60 Hz only when using two poles to switch both sides of Load. 30 Amps @ 28 VDC Resistive Each Pole. NEMA A600 Pilot Duty 50/60HZ Contact Material: TIMING Operate time Release Time: Silver Cadmium Oxide, Gold Flashed. 5/16" Diameter Standard. 40 Milliseconds Max. @ Nominal V 30 Milliseconds Max. @ Nominal V
18 70 290 6000
2.0 W 2.0 W 2.0 W 2.0 W
PRD11DGO-6 PRD11DGO-12 PRD11DGO-24 PRD11DGO-110
DIELECTRIC STRENGTH Between Open Contacts: 1500 V rms Mutually Insulated 2200 V rms Conductive elements: TEMPERATURE Operating Range: Non-Operating Storage range: LIFE Electrical (Rated Load): Mechanical (No Load): MISCELLANEOUS Coil Terminals: l Contact Terminals: Base Material: Weight: (AC) -30C to +50C, (DC) -30C +60C -30C to +100C 100,000 Operations 5,000,000 Operations 6-32 Binder Head Screws 8-32 Binder Head Screws Molded Phenolic, UL Recognized (QMFZ2) 11 oz. - 311 Grams approx. (DPDT)
RECTIFIED, AC OPERATED (DPDT) W199AXD-38 | 208, 240, 277 VAC See Note ||
PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION.
| ||
Built in Coil Diodes provide a wide range of Nominal Coil input voltages. This relay is suitable to Operate within a range of 208 Vac thru 277 Vac. 208 Vac = 2.3 VA, 240 Vac = 3.0 VA, 277 Vac = 4.0 VA.
AUXILIARY CONTACTS AND OTHER COIL VOLTAGES ARE AVAILABLE ON SPECIAL ORDER. CONTACT FACTORY FOR SPECIAL REQUIREMENTS.
PAGE 141
WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
OPEN STYLE POWER RELAY
CLASS 199 DPST-NO
UL Listed File No. E43641 COMPLIES WITH REQUIREMENTS OF IEC STANDARDS 947-4-1 AND 947-5-1 LOW VOLTAGE DIRECTIVE
CLASS
199
*
1-1/2 HP PER POLE 2 Hp - 2 POLE SWITCHING CLASS "B" COIL INSULATION SYSTEM
IEC = INTERNATIONAL * ELECTROTECHNICAL COMMISSION
OUTLINE DIMENSIONS
Dimensions shown in Inch & (Millimeters)
2.25 Max. (57.15) .375 (9.5)
UP
VERTICAL MOUNTING RECOMMENDED WITH CONTACTS UP
1.62 41.14 2.43 Max. (61.7)
2.50 (63.5)
1.87 (47.5 0.187 Dia. (2 Places)
SPECIFICATIONS CLASS 199 COIL Pull-in Voltage: Dropout Voltage: Coil Resistance: Max. Coil Dissipation: 80% DC Coils, 85% AC coils of nominal voltage or Less @ 25C 10% of Nominal Voltage or More @ 25C 10% Measured @ 25C DC Coils-4 Watts Max. Continuous.
CONTACTS Contact Combinations: DPST-NO Contact Rating each Pole: Each pole rated 30 Amps up to 300 VAC, 50/60Hz, 5 Amps @ 480/600VAC ,0.75pF Inductive load. 1-1/2 HP Motor Load (each Pole) @ 120 thru 600 VAC, 50/60 Hz. 2 HP Motor Load @ 200 thru 600 VAC, 50/60 Hz only when using two pole to switch both sides of Load 30 Amps @ 28 VDC Resistive load each Pole. NEMA A600 Pilot Duty 50/60Hz Contact Material: TIMING Operate time Release Time: Silver Cadmium Oxide, Gold Flashed. 5/16" Diameter Standard. 40 Milliseconds Max. @ Nominal V 35 Milliseconds Max. @ Nominal V
* RELEVANT IEC CONTACT UTILIZATION CATEGORIES
AC-1, AC-3, DC-1, AC-15
SEE SECTION 11, FOR RELEVANT UTILIZATION CATEGORIES
PART NUMBERS DPST-NO
COIL Measured @ 25C NOMINAL NOMINAL NOMINAL RESISPOWER INPUT TANCE VOLTAGE (OHMS) 10 VA 10 VA 10 VA
CROSS REFERENCE POTTER & BRUMFIELD
AC OPERATED (DPST-NO) W199AX-8 24 VAC W199AX-9 120 VAC W199AX-10 240 VAC, 60 Hz 220 VAC, 50 Hz DC OPERATED (DPST-NO) PRD7AGO-24 PRD7AGO-120 PRD7AGO-240
DIELECTRIC STRENGTH Between Open Contacts: 1500 V rms Mutually Insulated Conductive elements: 2200 V rms TEMPERATURE Operating Range: Non-Operating Storage range: LIFE Electrical (Rated Load): Mechanical (No Load): MISCELLANEOUS Coil Terminals: Contact Terminals: Base Material: Weight: (AC) -30C to +50C, (DC) -30C +60C -30C to +100C 100,000 Operations 5,000,000 Operations 6-32 Binder Head Screws 8-32 Binder Head Screws Molded Phenolic, UL Recognized (QMFZ2) 9 oz. - 255 Grams approx... (DPST-NO)
W199X-7 W199X-8
12 VDC 24 VDC
70 290
2.0 W 2.0 W
PRD7DGO-12 PRD7DGO-24
PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION.
AUXILIARY CONTACTS AND OTHER COIL VOLTAGES ARE AVAILABLE ON SPECIAL ORDER. CONTACT FACTORY FOR SPECIAL REQUIREMENTS.
WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
PAGE 142
C L A SS
199
OPEN STYLE POWER RELAY
CLASS 199DB
SPST-NO-DM WITH UL Listed MAGNETIC BLOWOUT File No. E43641 FOR DC ARC QUENCING
OUTLINE DIMENSIONS
Dimensions shown in Inch & (Millimeters)
COMPLIES WITH REQUIREMENTS OF IEC STANDARDS 947-4-1 AND 947-5-1 LOW VOLTAGE DIRECTIVE
*
IEC = INTERNATIONAL * ELECTROTECHNICAL COMMISSION
MAGNETIC Blowout
2.18 Max. (55.4) .375 (9.5)
UP
VERTICAL MOUNTING RECOMMENDED WITH CONTACTS UP
0.10 (2.54)
2.50 (63.5)
1.87 (47.5) 0.187 Dia. (2 Places)
1.62 41.14 2.43 Max. (61.7)
SPECIFICATIONS CLASS 199 COIL Pull-in Voltage: Dropout Voltage: Coil Resistance: Max. Coil Dissipation: CONTACTS Contact Combinations: Contact Rating : 80% DC Coils, 85% AC coils of nominal voltage or Less @ 25C 10% of Nominal Voltage or More @ 25C 10% Measured @ 25C DC Coils-4 Watts Max. Continuous. TIMING Operate time: Release Time: 40 Milliseconds Max. @ Nominal V 30 Milliseconds Max. @ Nominal V
SPST-NO-DM Double Make 30 Amps up to 300 VAC, 50/60Hz, 5 Amps @ 480/600Vac,0.75pFInductive Load. 1-1/2 HP Motor Load (each Pole) @ 120 thru 600 VAC, 50/60 Hz. 2 HP Motor Load @ 200 thru 600 VAC, 50/60 Hz only when using two poles to switch . 30 Amps @ 28 VDC Resistive Each Pole. NEMA A600 Pilot Duty 50/60Hz 20 Amps @ 110 VDC, Resistive; 8 Amps at 220 VDC, Resistive, 4 Amps @ 325VDC Resistive. 2 amps @ 500 VDC resistive. For Inductive Loads, contacts must be derated accordingly. Capacitive loads must be limited to insure that inrush current will not exceed 100 Amps. Silver Cadmium Oxide, Gold Flashed. 5/16" Diameter Standard.
DIELECTRIC STRENGTH Between Open Contacts: 1500 V rms Mutually Insulated Conductive elements: 2200 V rms TEMPERATURE Operating Range: Non-Operating Storage range: LIFE Electrical (Rated Load): Mechanical (No Load): MISCELLANEOUS Coil Terminals: Contact Terminals: Base Material: Weight: (AC) -30C to +50C, (DC) -30C +60C -30C to +100C 100,000 Operations 5,000,000 Operations 6-32 Binder Head Screws 8-32 Binder Head Screws Molded Phenolic, UL Recognized (QMFZ2) 8 oz. - 227 Grams approx. (SPST-NO-DM)
Additional Ratings, with Blowout Magnet for DC switching:
Contact Material:
* RELEVANT IEC CONTACT UTILIZATION CATEGORIES
AC-1, AC-3, DC-1, AC-15
SEE SECTION 11, FOR RELEVANT UTILIZATION CATEGORIES
COIL Measured @ 25C CROSS NOMINAL NOMINAL NOMINAL REFERENCE RESISPOWER POTTER & INPUT BRUMFIELD VOLTAGE TANCE (OHMS) AC OPERATED (SPST-NO-DM WITH MAGNETIC BLOWOUT) PART NUMBER W199ADBX-4 120 VAC 10 VA PRD3AJ0-120
PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION.
AUXILIARY CONTACTS AND OTHER COIL VOLTAGES ARE AVAILABLE ON SPECIAL ORDER. CONTACT FACTORY FOR SPECIAL REQUIREMENTS.
PAGE 143
WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
DOUBLE MAKE OR BREAK POWER RELAYS
UL Listed File No. E43641 COMPLIES WITH REQUIREMENTS OF IEC STANDARDS 947-4-1 AND 947-5-1 LOW VOLTAGE DIRECTIVE
CLASS
199
CLASS 199 SPST-NC-DB OR SPST-NO-DM
RATED 30 AMPS @ 2 HP CLASS "B" COIL INSULATION SYSTEM
*
IEC = INTERNATIONAL * ELECTROTECHNICAL COMMISSION
OUTLINE DIMENSIONS
Dimensions shown in Inch & (Millimeters)
2.25 Max. (57.15) .375 (9.5)
UP
VERTICAL MOUNTING RECOMMENDED WITH CONTACTS UP
1.62 41.14 2.43 Max. (61.7)
SPST-NC-DB
1.87 2.50 (47.5) (63.5) 0.187 Dia. (2 Places)
0.10 (2.54)
SPECIFICATIONS CLASS 199 COIL Pull-in Voltage: Dropout Voltage: Coil Resistance: Max. Coil Dissipation: CONTACTS Contact Combinations: Contact Rating SPST-NO-DM: 80% DC Coils, 85% AC coils of nominal voltage or Less. @ 25C 10% of Nominal Voltage or More @ 25C 10% @ 25C DC Coils-4 Watts Max. Continuous. SPST-NC (Double Break SPST-NO (Double Make 30 Amps up to 300 VAC, 50/60Hz 12 Amps @ 480, 10 Amps @ 600VAC,50/60 0.75pFInductive Load. 2 HP Motor Load @ 120 thru 600 VAC, 50/60 Hz. 30 Amps @ 28 VDC Resistive load. NEMA A600 Pilot Duty 50/60Hz Silver Cadmium Oxide, Gold Flashed. 5/16" Diameter Standard. 40 Milliseconds Max. @ Nominal V 30 Milliseconds Max. @ Nominal V SPST-NO-DM
:Contact Material: TIMING Operate time Release Time: DIELECTRIC STRENGTH Between Open Contacts: Mutually Insulated Conductive elements: TEMPERATURE Operating Range: Non-Operating Storage range: LIFE Electrical (Rated Load): Mechanical (No Load): MISCELLANEOUS Coil Terminals: Contacts Terminals: Base Material: Weight:
* RELEVANT IEC CONTACT UTILIZATION CATEGORIES
AC-1, AC-3, DC-1, AC-15
SEE SECTION 11, FOR RELEVANT UTILIZATION CATEGORIES
1500 V rms 2200 V rms (AC) -30C to +50C, (DC) -30C +60C -30C to +100C 100,000 Operations 5,000,000 Operations 6-32 Binder Head Screws 8-32 Binder Head Screws Molded Phenolic, UL recognized (QMz2) 8 oz. - 227 Grams approx.
COIL Measured @ 25C CROSS NOMINAL NOMINAL REFERENCE RESISPOTTER & POWER TANCE BRUMFIELD (OHMS) DC OPERATED (SPST-NC-DB WITH 30 AMP SCREW TERMINALS) PRD4DG0-12 70 2.0 W W199DYX-2 12 VDC AC OPERATED (SPST-NO-DM WITH 30 AMP SCREW TERMINALS) PART NUMBERS NOMINAL INPUT VOLTAGE W199ADX-4 120 VAC W199ADX-5 240 VAC, 60 Hz 220 VAC, 50 Hz 10 VA 10 VA PRD3AG0-120 PRD3AG0-240
DC OPERATED (SPST-NO-DM WITH 30 AMP SCREW TERMINALS) W199DX-2 W199DX-3 12 VDC 24 VDC 70 290 2.0 W 2.0 W PRD3DG0-12 PRD3DG0-24
PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION.
AUXILIARY CONTACTS AND OTHER COIL VOLTAGES ARE AVAILABLE ON SPECIAL ORDER. CONTACT FACTORY FOR SPECIAL REQUIREMENTS.
WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
PAGE 144
CLASS
199
DOUBLE MAKE POWER RELAYS
CLASS 199 SPST-NO-DM
RATED 50 AMPS - 2HP WITH BOX TERMINALS. CLASS "B" COIL INSULATION SYSTEM
UL Listed File No. E43641 COMPLIES WITH REQUIREMENTS OF IEC STANDARDS 947-4-1 AND 947-5-1 LOW VOLTAGE DIRECTIVE
*
IEC = INTERNATIONAL * ELECTROTECHNICAL COMMISSION
S BO HOW X T NW I ER MIN TH AL S
OUTLINE DIMENSIONS
Dimensions shown in Inch & (Millimeters)
50 AMP BOX TERMINALS ACCEPT NO.14 THRU NO. 6 AWG. WIRE
Box Terminal's 2.18 Max. (55.4) .375 (9.5)
UP
2.50 (63.5) 1.87 (47.5) 0.187 Dia. (2 Places)
2.43 Max. (61.7) 3.50 Max. (88.9)
1.62 41.14
0.10 (2.54) RECOMMENDED WITH
VERTICAL MOUNTING CONTACTS UP
SPECIFICATIONS CLASS 199 COIL Pull-in Voltage:
* RELEVANT IEC CONTACT UTILIZATION CATEGORIES
AC-1, AC-3, DC-1, AC-15
SEE SECTION 11, FOR RELEVANT UTILIZATION CATEGORIES
Dropout Voltage: Coil Resistance: Max. Coil Dissipation: CONTACTS Contact Combinations: Contact Ratings :
80% DC Coils, 85% AC coils of nominal voltage or Less. @ 25C 10% of Nominal Voltage or More @ 25C 10% @ 25C DC Coils-4 Watts Max. Continuous. SPST-NO Double Make 50 Amps up to 300 VAC, 50/60Hz 50 Amps @ 28 VDC Resistive load. Loads must be current limited as not to exceed 100 Amp inrush Currents. NEMA A600 Pilot Duty 50/60Hz Silver Cadmium Oxide, Gold Flashed. 5/16" Diameter Standard. 40 Milliseconds Max. @ Nominal V 30 Milliseconds Max. @ Nominal V
COIL Measured @ 25C CROSS NOMINAL NOMINAL NOMINAL REFERENCE RESISPOTTER & INPUT POWER TANCE BRUMFIELD VOLTAGE (OHMS) AC OPERATED (SPST-NO-DM WITH 50 AMP BOX TERMINALS) PART NUMBERS W199ADEX-4 120 VAC 10 VA PRD3AP4-120 DC OPERATED (SPST-NO-DM WITH 50 AMP BOX TERMINALS) W199DEX-3 24 VDC 290 2.0 W PRD3DP4-24
Contact Material: TIMING Operate time Release Time: DIELECTRIC STRENGTH Between Open Contacts: Mutually Insulated Conductive elements: TEMPERATURE Operating Range: Non-Operating Storage range: LIFE Electrical (Rated Load): Mechanical (No Load): MISCELLANEOUS Coil Terminals: Contacts Terminals: Base Material: Weight:
1500 V rms 2200 V rms (AC) -30C to +50C, (DC) -30C +60C -30C to +100C 100,000 Operations 5,000,000 Operations 6-32 Binder Head Screws 8-32 Binder Head Screws Molded Phenolic, UL Recognized (QMFZ2) 8 oz. - 227 Grams approx.
PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION.
AUXILIARY CONTACTS AND OTHER COIL VOLTAGES ARE AVAILABLE ON SPECIAL ORDER. CONTACT FACTORY FOR SPECIAL REQUIREMENTS.
PAGE 145
WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
DC SWITCHING POWER RELAY
CLASS 199B
UL Listed File No. E43641 COMPLIES WITH REQUIREMENTS OF IEC STANDARDS 947-4-1 AND 947-5-1 LOW VOLTAGE DIRECTIVE
CLASS
199
*
IEC = INTERNATIONAL * ELECTROTECHNICAL COMMISSION
DPDT WITH MAGNETIC BLOWOUT FOR DC ARC QUENCHING 10 AMP @ 110 VDC CLASS "B" COIL INSULATION SYSTEM
OUTLINE DIMENSIONS
Dimensions shown in Inch & (Millimeters) SPECIFICATIONS CLASS 199 COIL Pull-in Voltage: Dropout Voltage: Coil Resistance: Max. Coil Dissipation: CONTACTS Contact Combinations: Contact Rating :
MAGNETIC BLOW OUT
80% DC Coils, 85% AC coils of nominal voltage or Less @ 25C 10% of Nominal Voltage or More TM 25C 10% @ 25C DC Coils-4 Watts Max. Continuous. DPDT 30 Amps up to 300 VAC, 50/60Hz 5 Amps @ 480/600VAC ,0.75pFInductive Load. 1-1/2 HP Motor Load (each Pole) @ 120 thru 600 VAC, 50/60 Hz. 2 HP Motor Load @ 200 thru 600 VAC, 50/60 Hz only when using two poles to switch both sides of Load 30 Amps @ 28 VDC Resistive Each Pole. NEMA A600 Pilot Duty 50/60 Hz 10 Amps @ 110 VDC, Resistive; 4 Amps at 220 VDC, Resistive, 2 Amps @ 325VDC Resistive. For inductive Loads, contacts must be derated accordingly. Capacitive loads must have current limiting to insure that inrush current will not exceed 50 Amps Silver Cadmium Oxide, Gold Flashed. 5/16" Diameter Standard. 40 Milliseconds Max. @ Nominal V 30 Milliseconds Max. @ Nominal V
MAGNETIC BLOW OUT
2.53 Max. (64.3)
2.50 (63.5)
1.87 (47.5 0.187 Dia. (2 Places)
.375 (9.5)
3.12 (79.24
1.62 (41.14)
UP
VERTICAL MOUNTING RECOMMENDED WITH CONTACTS UP
DC Ratings:
Contact Material: TIMING Operate time: Release Time:
* RELEVANT IEC CONTACT UTILIZATION CATEGORIES
AC-1, AC-3, DC-1, AC-15
SEE SECTION 11, FOR RELEVANT UTILIZATION CATEGORIES
DIELECTRIC STRENGTH Between Open Contacts: 1500 V rms Mutually Insulated 2200 V rms Conductive elements: TEMPERATURE Operating Range: Non-Operating Storage range: LIFE Electrical (Rated Load) Mechanical (No Load) MISCELLANEOUS Coil Terminals: Contact Terminals: Base Material Weight: (AC) -30C to +50C, (DC) -30C +60C -30C to +100C 100,000 Operations 5,000,000 Operations 6-32 Binder Head Screws 8-32 Binder Head Screws Molded Phenolic, UL Recognized (QMFZ2) 11 oz. - 312 Grams approx.. (DPDT) PART NUMBERS
COIL Measured @ 25C NOMINAL NOMINAL NOMINAL RESIS- POWER INPUT TANCE VOLTAGE (OHMS)
CROSS REFERENCE POTTER & BRUMFIELD
AC OPERATED (DPDT WITH BLOW OUT MAGNET) PRD11AJ0-120 10 VA W199ABX-14 120 VAC DC OPERATED (DPDT WITH BLOW OUT MAGNET) W199BX-14 110 VDC 6000 2.0 W PRD11DJ0-110
PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION.
AUXILIARY CONTACTS AND OTHER COIL VOLTAGES ARE AVAILABLE ON SPECIAL ORDER. CONTACT FACTORY FOR SPECIAL REQUIREMENTS.
WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
PAGE 146
SERIES
425
OPEN STYLE - 3 POLE, 30 AMP POWER RELAY
The series 425 Power relay is capable of handling up to 30 Amps and 1 Hp Loads. The Series 425 has sufficient spacing to allow for 600 Vac contact ratings . The Design features a enclosed coil, Screw Terminals and Silver Cadmium Oxide contacts as standard. The Series 425 has a wide choice of options to choose from.
OUTLINE DIMENSIONS
Dimensions shown are in INCHES and (millimeters)
3PDT
CONTACT LOAD RATINGS 3 POLE RELAYS Load 30/DC 120-240/AC 208-240/AC 277/AC 600/AC General Duty 30A 17A 10A 25A 25A 1O 1HP Motor (45% PF) 1O 1HP 3O 3HP PER POLE 0.20 Dia.Typ.
3.24 (82.3) 1.675 (42.5)
COIL SPECIFICATIONS 3 POLE RELAYS @ 25C Nominal Voltage 12 24 48 120 * 240 ** 480 Resistance Ohms 10% AC 1.8 6.7 27 170 680 2720 Resistance Ohms 10% DC 35.5 142 568 2980 Current (MA) Power Consumption AC AC DC DC 11VA 4.0W 1600 333 11VA 4.0W 820 169 11VA 4.0W 410 84 85 18-21 11VA 4.0W 11VA 43 11VA 22 -
2.50 (63.5)
1.875 (47.6)
UP
VERTICAL MOUNTING RECOMMENDED WITH CONTACTS UP
* AC Coil is 120V, 50/60Hz, DC Coil is 110-125VD ** For 220 VDC use 3600 , 10 Watt resistor in series with 110 VDC relay.
1, 2, and 3 Pole Relays Min. Operate:
AC: 85% of nominal Voltage or less @ 25C DC: 75% of nominal Voltage or less @ 25C Max. Over Voltage: 110% of nominal
Struthers-Dunn
ORDERING CODE Typical Type No.
ULRecognized File No. E13224
GENERAL SPECIFICATIONS Silver Cadmium Oxide. 30 mS Max. @ Nominal Voltage. 15 mS Max. @ Nominal Voltage.
425 XCX
-120A
CONTACTS Contact Material: TIMING Operate Time: Release Time:
Series 425 Screw Terminal, 30A, 1-3 Pole Contact Arrangements Insulated Armature Types (600V) CXX 3PST-NO XCX 3PDT Options Tungsten Contacts (High Inrush) - CODE W 0.25 inch quick connect terminals- CODE 18 1 Aux. Contact (SPDT Snap Switch, 10A ) - CODE 90 2 Aux. Contact (SPDT Snap Switches, 10A ) - CODE 91 Coil Voltage AC: 6, 12, 24, 48, 120, 240, 480 (Add "A") DC: 6, 12, 24, 48, 110 -125 (Add "D")
INSULATION CHARACTERISTICS Dielectric Strength 2500 V rms between Mutually insulated current carrying parts and those parts to ground. Insulation Resistance: 500 VDC Exceeds 1000 Megohms. ENVIRONMENTAL CAPABILITIES Ambient Temperature Rating: AC: -55C to +45C @ Rated Operation. DC: -55C to +80 C LIFE EXPECTANCY Mechanical: Electrical: MISCELLANEOUS Enclosure: Weight: 10 Million Operations no load 100,000 Operations @ Rated Load. Open Style Small Base 9oz. large base 11 oz.approx.
PAGE 147
WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
OPEN STYLE 30 AMP POWER RELAY
CLASS 88UKD RELAY
SIDE COIL SOLDER TERMINALS UL Recognized File No. E43641 SPST-N.O. DM, RATED 30 AMPS 1/4"QUICK CONNECT /SOLDER TERMINALS SWITCHES UP TO 1 HP AT 600 VAC
1.25Max. (31.7)
CLASS
88UKD
1.937. (49.1)
1.406 (35.7) .250 (6.35)
.078 (1.98)
.062 (1.57) .437 (11.1)
6-32 tapped mt. hole x .312 deep
.156 (3.9)
SPECIFICATIONS 88UKD
COIL Pull-in Voltage (AC): Pull-in Voltage (DC): Dropout Voltage: Max. allowed voltage Coil Resistance: CONTACTS Contact Material: Contact Resistance: Contact Rating: 85% of Nominal Voltage or less 80% of Nominal Voltage or less 10% of nominal voltage or more 110% of nominal voltage 10% Measured @ 25C 1/4' silver alloy, gold flashed. Initial 50 Milliohms @ rated current. 30 Amps up to 300VAC/28VDC, Resistive Load 5 Amps @ 600VAC Resistive.Load 1 HP @ 120-600 VAC Motor load. 25 mS Max. @ Nominal Voltage. 20 mS Max. @ Nominal Voltage TEMPERATURE Operating: -10C to +50C @ Rated Operation. (AC ) -10C to +60C @ Rated Operation. (DC )
VIBRATION RESISTANCE Functional: 5g's 10 to 55Hz. SHOCK RESISTANCE Functional: LIFE EXPECTANCY Mechanical: Electrical: MISCELLANEOUS Contact Insulation: Style: Mounting: Weight: 5g's 11mS Max. 5 Million Operations 100,000 Operations @ Rated Load. Movable & stationary contacts are mounted on a molded plastic barrier insulator. Open style construction. 6-32 tapped hole and locating tab. 85 Grams, 3 oz. approx.
TIMING Operate Time: Release Time: DIELECTRIC STRENGTH Contacts to coil: Across open contacts: Contacts to frame: Insulation Resistance:
3000 V rms 1000 V rms 3000 V rms 1000 megohms min. @ 500 VDC
Coil Measured @ 25C
NOMINAL INPUT VOLTAGE AC OPERATED COIL 24VAC 120VAC 240VAC,60Hz 220VAC,50Hz DC OPERATED COIL 12 VDC W88UKDX-2 24 VDC W88UKDX-3 110 VDC W88UKDX-4 W88UKADX-3 W88UKADX-4 W88UKADX-5 PART NUMBERS NOMINAL NOMINAL RESISTANCE POWER (OHMS) 100 400 8000 3VA 3VA 3VA 1.5W 1.5W 1.5W
CROSS REFERENCE TO POTTER & BRUMFIELD
KR-3AH-24 KR-3AH-120 KR-3AH-240
KR-3DH-12 KR-3DH-24 KR-3DH-110
PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION. PART NUMBER SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION
WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
PAGE 148
SERIES
415
SCREW TERMINAL 15 AMP, 1 AND 2 POLE POWER RELAY
R
Listed (XBX Only)
file No. E13224
The Series 415 is a compact, 15 amp base mounted industrial relay. It is a versatile relay that offers a variety of contact configurations and options. Excellent contact life assures long mechanical life and contact reliability on low level loads. Screw terminals are standard. Options include: high voltage or high inrush contacts, quick connect terminals, permanent magnet blowout and low power DC coils.
OUTLINE DIMENSIONS
Dimensions shown in Inch and (Millimeters)
1.87 (47.4) 1.50 (38.1)
2.75 (69.85) 2.35 (59.69)
4 mtg.holes 0.181 .005 Dia.
UP
VERTICAL MOUNTING RECOMMENDED WITH CONTACTS UP
MAXIMUM DEPTH DIMENSION OF CONTACTOR 1.75", (44.45)
WIRING DIAGRAMS
TOP VIEW 415XAX 415BXX
Struthers-Dunn
ORDERING CODE Typical Type No.
415XBX
415HXX
415
XBX
18
-120A
Series 415 Screw Terminals, 15 Amp 1 and 2 pole Contact Arrangements BXX (DPST-NO. HXX (SPST-NO-DM XAX (SPDT) XBX (DPDT) XHX (SPDT-DB-DM XXH (SPST-NC-DB Options 0.25 inch quick connect terminals - CODE 18 Permanent Magnet Blowout - CODE 69 (Consult Factory for other options) Coil Voltage AC: 6, 12, 24, 48, 120, 240, (Add "A") DC: 6, 12, 24, 32, 48, 115-125 (Add "D") Special coils: Low Power (mW), series coils. High Inrush contacts: 10 Amps continuous, 150 Amp Inrush. High Voltage Contacts: Up to 4KV
415XXH
415XHX
PAGE 149
WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
SCREW TERMINAL 15 AMP, 1 AND 2 POLE POWER RELAY
SERIES
415
CONTACT RATINGS LOAD RESISTIVE MOTOR (80% pF) 30/VDC 15A 120VAC 15A 1/2HP 240VAC 10A 1HP
CROSS REFERENCE STRUTHERS-DUNN TO WARD LEONARD
STRUTHERS-DUNN WARD LEONARD DC COIL 2 POLE N.O. 415BXX-6D 105-1420 415BXX-12D 105-3420 415BXX-24D 105-4420 415BXX-110D 105-6420 DC COIL 2 POLE N.C.. 415XXB-6D 105-1421 415XXB-12D 105-3421 415XXB-24D 105-4421 415XXB-110D 105-6421 DC COIL DPDT 415XBX-6D 105-1422 415XBX-12D 105-3422 415XBX-24D 105-4422 415XBX-110D 105-6422 AC COIL 2 POLE N.O.. 415BXX-6A 105-1520 415BXX-12A 105-3520 415BXX-24A 105-4520 415BXX-120A 105-6520 AC COIL 2 POLE N.C.. 415XXB-6A 105-1521 415XXB-12A 105-3521 415XXB-24A 105-4521 415XXB-120A 105-6521 415XXB-240A 105-7521 AC COIL DPDT 415XBX-6A 105-1522 415XBX-12A 105-3522 415XBX-24A 105-4522 415XBX-120A 105-6522 415XBX-240A 105-7522 NOTE: THE 105 STYLE IS SLIGHTLY SMALLER WITH A DIFFERENT MOUNTING HOLE PATTERN.
AC COIL SPECIFICATIONS @ 25C (6VA) mA @ nominal voltage Nominal Voltage Resistance Inrush Sealed (60HZ) Ohms 10% Current Coil 6 1000 1.5 1800 12 500 6.3 900 250 24 25 450 48 125 100 225 120 50 620 90 240 25 2500 45
DC COIL SPECIFICATIONS @ 25C (3.5W) Nominal Voltage Resistance mA @ nominal voltage Coils Coils (VDC) Ohms 10% Cold Hot 6 500 10 600 12 250 40 300 24 125 155 150 32 95 390 112 48 62 620 75 *115/125 26 4000 31 * 220-250 VDC relays supplied with resistor in series with 115/125 VDC coil.
GENERAL SPECIFICATIONS
COIL Pull-in Voltage: Dropout Voltage: Max. allowed voltage: Coil Resistance: CONTACTS Contact Material: TIMING Operate Time: Release Time: 80% of nominal voltage or less measured at 25C 10% of nominal voltage or more @ 25C 110% of nominal voltage 10% Measured @ 25C Silver Cadmium Oxide. 25 mS Max. @ Nominal Voltage. 10mS Max. @ Nominal Voltage.
DIELECTRIC STRENGTH All Mutually Insulated Points: 1500 V rms between all mutually Insulated current carrying parts and those parts to ground. Insulation Resistance: 500 VDC Exceeds 1000 Megohms. TEMPERATURE Temperature Rating: LIFE EXPECTANCY Mechanical: Electrical: AC: -45C to +55C @ rated operation. DC: -45C to +70C @ rated operation 20 Million Operations no load 200,000 Operations @ Rated Load. 500,000 Operations @ 1/2 rated load. 4 oz. (113 g) approx.
MISCELLANEOUS Weight:
WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
PART NUMBER SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION
PAGE 150
SERIES
A275
MOTOR REVERSING CONTACTOR, 1 & 3 HP, 6 POLE
UL Recognized File No. E13224B
The Series A275 relay is a 2 coil, compact motor reversing contactor which finds extensive applications in the Industrial door operator Industry, the hoist Industry and electronic wheel balancers, to name a few. The A275 has Q.C. coil terminals extending out the back (opposite the contact terminals), mechanically interlocked armatures is a standard feature.
OUTLINE DIMENSIONS
Dimensions shown in Inch and (Millimeters)
2.985 (75.81 2.56 (65.0) 2.31 (58.9)
1.59 (40.3) 3.37 (85.6)
UP
.187 (4.76) 2 holes for #8 screws
RECOMMENDED MOUNTING POSITION
3.62 (91.9)
A U X
2.75 (69.8)
WIRING DIAGRAM
Struthers-Dunn
ORDERING CODE Typical Type No.
TOP VIEW Main contact terminals are numbered on contactor
A275
KXX
90
-24A
1 4 7
2 5 8
3 6 9
Series A275, 1/4" Terminals, motor reversing. Continuous , 1 & 2 Hp, 3 pole models Contact Arrangements KXX (3PDM-NO., per coil) Options 2 Aux. contacts, each SPDT (1 per coil) 1/4" Q.C. terminals - CODE 90 4 Aux. contacts, each SPDT (2 per coil) 1/4" Q.C. terminals - CODE 91 Rectified Coil - CODE V2 Coil Voltage AC: 12, 24, 110, 120, 220, 240 (Add "A") DC: 12, 24, 32, 48, 120 (Add "D") OPTIONS (CONSULT FACTORY)
Auxiliary contact Snap Switches
PAGE 151
WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
MOTOR REVERSING CONTACTOR, 1 & 3 HP, 6 POLE
SERIES
A275
GENERAL SPECIFICATIONS COIL Pull-in Voltage: Dropout Voltage: Max. allowed voltage: Coil Resistance: CONTACTS Contact Material: TIMING Operate Time: Release Time: AC: 85%, DC: 80% of nominal voltage measured at 25C 10% of nominal voltage or more @ 25C 110% of nominal voltage 10% Measured @ 25C Silver Cadmium Oxide. 50 mS Max. @ Nominal Voltage. 30 mS Max. @ Nominal Voltage.
DIELECTRIC STRENGTH All Mutually Insulated Points: 2500 V rms between all mutually Insulated current carrying parts and those parts to ground. Insulation Resistance: 500 VDC Exceeds 1000 Megohms. TEMPERATURE Temperature Rating: LIFE EXPECTANCY Mechanical: Electrical: AC: -45C to +50C @ rated operation. DC: -45C to +70 C @ rated operation. 5 Million Operations no load 100,000 Operations @ Rated Load. 500,000 Operations @ 1/2 rated load. 1 pound, approx..
MISCELLANEOUS Weight:
CONTACT RATINGS
AC CONTACTS: Rated with all contacts in use, not rated per pole.
DC COIL SPECIFICATIONS @ 25C Resistance Power Ohms 10% Consumption 31.0 4.5W 125 4.6W 210 4.9W 500 4.6W 3240 4.4W Polypropylene encapsulated coils Nominal Voltage 12 24 32 48 120
VOLTAGE (60HZ) 120 240 240 480/600
PHASE 1-2-3 1 2-3 2-3
MOTOR RESISTIVE LOADS (HP) LOAD (AMPS) 15 1 10 1.5 10 3 5 3
DC CONTACTS VOLTAGE (DC) 30 125 RESISTIVE LOAD (AMPS) 15 5
AC COIL SPECIFICATIONS @ 25C Resistance Power Nominal Ohms 10% Consumption Voltage 17VA 1.24 12V/50-60hz 16.7VA 4.63 24V/50-60hz 16.8VA 125 110V/50-120V/60hz 16.8VA 500 220V/50-240V/60hz
600 volt spacing to ground. 300 volt spacing for auxiliary contacts.
WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
PAGE 152
SERIES
A575
2 COIL MOTOR REVERSING CONTACTOR 1.5 - 7.5HP, 6 POLE
The Series A575 relay is rated to 7.5 HP. Two sets of 3 pole, double-make, N.O. contacts are mechanically Interlocked to prevent simultaneous closure. Front mounted auxiliary contacts are available for electrical lockup and lockout. All versions have silver cadmium oxide contacts. The A575 motor reversing contactor is widely used for control of overhead doors, elevators, hoists, machine tools, and other similar devices that requires frequent jogging.
UL Recognized File No. E13224
OUTLINE DIMENSIONS Dimensions shown in Inch and (Millimeters)
NO NC COM NC
NO COM
4.43 (112.5)
2.56 (65.0) 3.40 (86.3)
UP
4.75 (120.6) 5.25 (132)
MTG. HOLES .196 DIA. (4.97) 2 PLACES
MAXIMUM DEPTH DIMENSION OF CONTACTOR 3.00", (76.2)
RECOMMENDED MOUNTING POSITION
WIRING DIAGRAM
1
3 6 9
Struthers-Dunn
ORDERING CODE Typical Type No.
4 7
A575
KXX
90
-24A
Series A575, Screw Terminals, 2 coil motor rev. contactor, 1.5 - 7.5 HP Contact Arrangements KXX (3PDM-NO., per coil) Options 1 Form SPST-NO & SPST-NC Aux. contacts per coil, Rated 5 Amps - CODE 74 SPDT Aux. contact per coil Rated 5 Amps. - CODE 90 Coil Voltage AC: 12, 24, 120, 240, 440, 550 (Add "A") DC: 12, 24, 115-125, 240 (Add "D") Mechanical Interlock omitted, Consult Factory OPTIONS (CONSULT FACTORY)
AUXILIARY CONTACTS
PART NUMBER SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION
PAGE 153
WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
2 COIL MOTOR REVERSING CONTACTOR 1.5 - 7.5HP, 6 POLE
SERIES
A575
GENERAL SPECIFICATIONS COIL Pull-in Voltage: Dropout Voltage: Max. allowed voltage: Coil Resistance: CONTACTS Contact Material: TIMING Operate Time: Release Time:
AC: 85%, DC: 80% of nominal voltage measured at 25C 10% of nominal voltage or more @ 25C 110% of nominal voltage 10% Measured @ 25C Silver Cadmium Oxide. 60 mS Max. @ Nominal Voltage. 30 mS Max. @ Nominal Voltage.
DIELECTRIC STRENGTH All Mutually Insulated Points: 2500 V rms between all mutually Insulated current carrying parts and those parts to ground. Insulation Resistance: 500 VDC Exceeds 1000 Megohms. TEMPERATURE Temperature Rating: LIFE EXPECTANCY Mechanical: Electrical: -40C to +50C @ rated operation.
MISCELLANEOUS Weight:
5 Million Operations no load 100,000 Operations @ Rated Load. 250,000 Operations @ 1/2 rated load. 1.5 pounds, approx..
AC COIL SPECIFICATIONS @ 25C (22VA) Nominal Voltage 12 24 *120 240 440 550 Resistance Ohms 10% 1.00 5.30 92.0 420 2100 3100 Nominal Current 1.833 AMP 0.917 AMP 0.183 AMP 0.920 AMP 0.050 AMP 0.040 AMP
CONTACT RATINGS VOLTAGE LOAD (60HZ) 120 3PST-DM-NO 208/240 208/240 (per pole) 480/600 PHASE 1 1 2-3 2-3 MOTOR RESISTIVE LOADS (HP) LOAD (AMPS) 30 1-1/2 30 3 30 5 15 7-1/2
* AC coil is 120, 50-60HZ LOAD 3PST-DM-NO (per pole) DC COIL SPECIFICATIONS @ 25C (10 WATT) Nominal Voltage 12 24 **120 240 Resistance Ohms 10% 16.5 58.2 1,450 4,200 Nominal Current 0.727 0.412 0.083 0.055
DC CONTACTS VOLTAGE (DC) 115 230 RESISTIVE LOAD (AMPS) 15 2
AUXILIARY CONTACTS LOAD 1 FORM "A" "B" OR "C" VOLTAGE (AC) 120 240 RESISTIVE LOAD (AMPS) 5 5
** DC coil is 110-125 VDC
WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
PART NUMBER SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION
PAGE 154
SERIES
101-102-103 50,100 & 200 AMP SINGLE POLE DC CONTACTORS
The Series 101, 102 and 103 are DC solenoid-actuated, heavy duty contactors. Each contactor has a single pole, double-make normally open contact. Contacts are enclosed with a molded plastic cover. The series 101 is rated at 50 amps continuous duty. The series 102 is rated 100 amps continuous and the series 103 is rated at 200 amps continuous. Coils are rated for DC only, as standard. The powerful magnetic structure creates very high contact pressure which results in very reliable and low resistance contacts, making them suitable for power applications in telecommunications, elevator and rail mass transit as well as other Industries.
OUTLINE DIMENSIONS
A E B F
UP
C
RECOMMENDED MOUNTING POSITION
(DEPTH FRONT TO BACK)
D
UP
Dimensions shown in Inch and (Millimeters) Dim. A B C D E F 101HXX 2.69 (68.33) 1.87 (47.4) 2.50 (63.5) 1.84 (46.7) 0.40 (10.1) 0.43 (10.9) 102HXX 3.38 (85.73) 2.25 (57.1) 3.22 (81.79) 2.09 (53.0) 0.56 (14.2) 0.50 (12.7) 103HXX 4.25 (107.9) 2.40 (60.9) 3.53 (89.66) 2.65 (67.31) 0.92 (23.3) 0.56 (14.2)
RECOMMENDED MOUNTING POSITION
Mounting holes (2) - .265 (6.73) Inch Dia.
Struthers-Dunn
ORDERING CODE Typical Type No.
102
HXX
-28D WIRING DIAGRAM
Series 101 Screw Term., 50 Amp, 1 pole 102 Screw Term., 100 Amp, 1 pole 103 Screw Term., 200 Amp, 1 pole Contact Arrangements HXX- 1 Pole D.M.- N.O. Standard. HXH- 2 Pole D.B. -1 N.C. and 1 N.O.103 only. JXX- 2 Pole D.M. N.O XRX- SPDT-M-B (Make before break, 103 only) XXH- 1Pole-D.B. + 1NC (103 only) Coil Voltage DC: 12, 28, 48, (Add "D") Note: Contact arrangements other than the standard HXX will require a 3 digit suffix number to be added to the type number. This is done by the factory and will be shown after the contact arrangement code. Contact factory for suffix number. OPTIONS (CONSULT FACTORY) AC COIL INPUT VOLTAGES NON STANDARD DC COIL VOLTAGES
101HXX 102HXX 103HXX
PART NUMBER SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION
PAGE 155
WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
SERIES
50,100 & 200 AMP SINGLE POLE DC CONTACTORS 101-102-103
GENERAL SPECIFICATIONS COIL Pull-in Voltage: Dropout Voltage: Max. allowed voltage: Coil Resistance: CONTACTS Contact Material: TIMING Operate Time: Release Time: DC: 80% of nominal voltage measured at 25C 10% of nominal voltage or more @ 25C 110% of nominal voltage 10% Measured @ 25C Silver Cadmium Oxide. 60 mS Max. @ Nominal Voltage. 30 mS Max. @ Nominal Voltage.
DIELECTRIC STRENGTH All Mutually Insulated Points: 1500 V rms between all mutually Insulated current carrying parts and those parts to ground. Insulation Resistance: 500 VDC Exceeds 1000 Megohms. TEMPERATURE Temperature Rating: LIFE EXPECTANCY Mechanical: Electrical: -45C to +65C @ rated operation. 500,000 Operations no load 100,000 Operations @ Rated Load. Coil 101 - #6-32 102 - #8-32 103 - #8-32 Load Term. #10-32 #1/4-20 #3/8-18
TERMINALS
MOUNTING Weight
Clearance Holes, ea. .265 in dia. 13 oz., 370 Grams
AC CONTACT RATINGS RESISTIVE LOAD (AMPS) VOLTAGE AC (60HZ) Series 101 Series 102 Series 103 50 120 200 100 50 240 200 100 DC CONTACT RATING VOLTAGE (DC) 30 RESISTIVE LOAD (AMPS) 50 100 200
DC COIL SPECIFICATIONS @ 25C Nominal Voltage (VDC) 12 28 48 101HXX (9W Max) 102HXX 103HXX (10.5W Max) (13.3W Max) Resistance Resistance Resistance Ohms 10% Ohms 10% Ohms 10% 17 10.8 26 75 59 98 290 173 267
PART NUMBER SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION
WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
PAGE 156
SERIES
214
20 AMP GROUND FAULT INTERRUPT (GFI) RELAY
The Series 214 Ground fault interrupt relay (GFI) to our knowledge, the smallest relay ever, to pass Underwriters Laboratories 20 Amp overload test for ground fault interrupting devices. Both resistive and Inductive loads of 120 Amps at 120 volts must be switched ten times each without failure. The 214 GFI is most commonly found in portable (plug) GFI equipment. This relay is also appropriate for other applications where size, weight, and the ability to safely handle occasional severe overloads is of primary importance.
UL Recognized File No. E13224
OUTLINE DIMENSIONS Dimensions shown in inch and (Millimeters)
# 17 AWG Stranded tinned copper wire insulated with .032 thick wall gray silicone rubber
1.37 (34.7) .839 (21.3)
WIRING DIAGRAM
+.000
.900 - .010 (22.8)
.900 - .010 0.30 Max. (7.62) (22.8)
+.000
C L
1.00 (25.4)
.500 (12.7)
Mounting hole # 6-32 thd. .375 deep min. with .250 full form threads
0.70 x .150 slot (2 places) 0.62 x .093 slot (2 places)
COIL SPECIFICATIONS @ 25C AC COIL 50/60hZ Nominal Nominal Resistance Voltage Ohms 10% Power (mA) (VDC) 360 6 5 175 20 12 90 24 80 17 115 2000 DC COIL Nominal Resistance Ohms 10% Power (mA) 30 120 480 10,000 200 100 50 11.5
VOLTAGE AC (50/60HZ) 120 240 VOLTAGE (DC) 30
RESISTIVE LOAD (AMPS) CONTINUOUS MAX. OVERLOAD 20 120 * 20 DC CONTACT RATING RESISTIVE LOAD (AMPS) 20 -
* Normally open contact switched 10 times GENERAL SPECIFICATIONS COIL Pull-in Voltage: Dropout Voltage: Max. allowed voltage: Coil Resistance: CONTACTS Contact Material: TIMING Operate Time: Release Time: DC: 80% of nominal voltage measured at 25C 10% of nominal voltage or more @ 25C 110% of nominal voltage 10% Measured @ 25C Silver Cadmium Oxide. 15 mS Max. @ Nominal Voltage. 15 mS Max. @ Nominal Voltage.
NOTE: Other DC voltages available with or without rectifiers installed. AC versions without rectifiers can be supplied but not recommended. Consult Factory
Struthers-Dunn
ORDERING CODE Typical Type No.
214
HXX
-24D
Series Open Style, Tapped pole piece with antirotation tab. solder terminals on .Coil, # 17 AWG wire contacts. Contact Arrangements HXX (1 Pole double make N.O.) Standard BXX DPST-NO (2 Form A) Coil Voltages AC: 6, 12, 24, 120 ( Add A) DC: 6, 12, 24, 110-125 (Add "D") OPTIONS The 214 GFI is normally custom built to meet each Customers unique requirements. Consult Factory.
DIELECTRIC STRENGTH All Mutually Insulated Points: 2000 V rms between all mutually Insulated current carrying parts and those parts to ground. Insulation Resistance: 500 VDC Exceeds 1000 Megohms. TEMPERATURE Temperature Rating: LIFE EXPECTANCY Mechanical: Overload: Electrical: -45C to +65C @ rated operation. 10,000,000 Operations no load 120 VAC @ 120 Amps, 10 cycles 100,000 Operations @ Rated Load. Coil Load Terminals Pierced Solder lug # 17 AWG. Silicone Rubber. Tapped pole piece & anti rotation Tab. Any 2.5 oz. 71 Grams
TERMINALS MISCELLANEOUS Mounting position: Weight:
PAGE 157
WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
PART NUMBER SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION
GENERAL SPECIFICATIONS
CLASS
MDR
MDR'S ARE IDEAL FOR SWITCHING RESISTIVE, TUNGSTEN, AND MOTOR LOADS FOR BOTH AC AND DC APPLICATIONS.
PROTECTIVE CO IL COVERS
UL Listed File No. E52197
HERMETICALLY SEALED IN STEEL TUBES Every contactor tube is hermetically sealed to provide maximum life, protection to the user from arcing and the hazards of switching heavy loads with exposed contacts. LIQUID MERCURY CONTACT Liquid mercury means a new contact surface after every operation. Mercury is self-renewing, it cannot pit, weld, disintegrate or oxidize. The internal resistance of the contact surfaces typically measure only a few Milliohms and is ideal for switching large loads safely.
SPECIFICATIONS MERCURY DISPLACEMENT RELAYS COIL Frequency of Operation: Pull-in voltage Dropout voltage CONTACTS Material: Contact resistance:
60 per minute maximum 80% of nominal voltage, Typ. AC & DC coils. 78% of nominal voltage, typ. AC coils 65% of nominal voltage, typ. DC coils Mercury .002 ohm M60 & M100 .003 ohm M30 & M35
TIMING Operate (at nominal voltage) Dropout (at nominal voltage)
50 Milliseconds typical 80 Milliseconds typical
DIELECTRIC STRENGTH All mutually insulated points to ground: 2650 V rms TEMPERATURE Operating: LIFE Mechanical: (No load) Electrical (Rated load) MISCELLANEOUS Insulation Material:
- 35C to + 60C Under continuous load.
5,000,000 Operations 250,000 Operations
Mounting: Options:
Class B - 130C & M35 pressure connectors for AWG 6-14 wire; M60 pressure connectors for AWG 2 - 12 wire Vertical 10 Combination of SPST-NO & SPST-NC contact configurations. available. Other coil voltages available .
WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
PAGE 158
CLASS
MDR
APPLICATION DATA
MERCURY DISPLACEMENT TUBE
GLASS INSULATOR WELD
PLUNGER GUIDE CERAMIC LINER ELECTRODE ARC QUENCHING ATMOSPHERE MAGNETIC LINER PLUNGER GUIDE BUFFER SPRING MERCURY POOL STAINLESS STEEL CAN
PRINCIPLE OF OPERATION The sectional view shows our normally open style Mercury Displacement tube with the plunger assembly floating on the mercury pool. When the coil power is off, the mercury level is below the electrode tip. No electrical path exists between the electrode and mercury pool. When coil power is applied, the plunger is drawn down into the mercury by the pull of the magnetic field. This action raises the mercury level, so it covers the end of the electrode closing the circuit. When coil power is turned off, the buoyant force of the mercury causes the plunger assemble to rise, dropping the mercury level, and breaking the circuit. APPLICATION DATA Mercury Displacement relays are ideal for adverse environments....Where high inrushes are encountered ....Where hermetically sealed contact operation is required because of corrosive, dirty, or moist ambient conditions. ....Where use does not permit contact maintenance. ....Where reduced noise levels are required. ....where minimum weight and size are desired. DESIGN FEATURES Liquid Mercury Contact - provides a new contact surface with every actuation. Mercury is self-renewing and does not pit, weld, disintegrate or oxidize. Hermetic sealing - provides internal and external protection from arcing. Inert Gas atmosphere - contactor tube is evacuated, then pressurized with a combination of gases which extinguish arcing and contribute to long life. The pressurized gases provide for a high dielectric withstanding voltage between contact surfaces. Low Contact Resistance - Large electrode and mercury volume creates low contact resistance and provides high inrush current capability. Quiet Operation - Switch clacking normally associated with conventional hard contactors, is eliminated with mercury displacement tubes and the buffer spring assembly. APPLICATION OF "M" SERIES VS "ML" SERIES The series "ML" is physically the same as the "M" series except for the type of gases used in the contactor tubes. The "ML" series was developed for use with resistive and tungsten loads on AC power ONLY. The "ML" series will give much greater life than the "M" series for these types of loads and is intended for high activation use, such as molding machines or ovens. The "ML" series, however is not intended for use with motor loads on AC power, or for resistive, tungsten, or motor loads on DC power. The "M" series, which is our universal series is rated to be used on all types of loads resistive, tungsten, and motor for both AC and DC power
PAGE 159
WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
30 AMP MERCURY DISPLACEMENT RELAY
CLASS M30
RATED 30 AMPS SWITCHES RESISTIVE TUNGSTEN, AND MOTOR LOADS 1 POLE N.O. CONTACT
CLASS
MDR
CONTACTOR TERMINALS
.180 Dia. (4.6) 2 Holes
4.18 (106.4)
2.03 (51.6)
UL Listed File No. E52197
COIL TERMINALS
1.62 (41.3)
1.187 (30.2) 2.0 (50.8)
2.12 (58.7)
.531 (13.5)
UP
RECOMMENDED MOUNTING POSITION 10
FOR EXTENDED LOAD LIFE WHEN SWITCHING RESISTIVE AND TUNGSTEN LOADS ORDER THE ML30-STYLE. OTHER COIL VOLTAGE AND CONTACT COMBINATIONS AVAILABLE. CONSULT FACTORY. Construction in accordance with VDE 0660 and 0110 (Insulation group 380) Weigh: 13 ozs. 370 grams CONTACTOR RATINGS FOR M30A - M30B RESISTIVE MOTOR HP PHASE AMPS AMPS 1O 3O 1O 3O 24 1O 3O 2* 19.2 3* 30* 28 5* 19 7.5* 30* 1O 3O 1O 3O 14 5* 10* 14 30* 11.2 11 5* 10* 1O 3O 25 ** DC 1/2 30* 27 DC 1/2 30* 13.5 DC 1/2 16* 5.2 DC 1/2 12* 2.6 ** CSA only
VOLTAGE 120VAC 240VAC 480VAC 600VAC 24VDC 48VDC 125VDC 250VDC
TUNGSTEN AMPS 30* 15 7.5 6 30* 30* 16* 12*
* UL and CSA Listed
PART NUMBER WM30A-120A
NOMINAL INPUT VOLTAGE 120 VAC
COIL Measured @ 25C NOMINAL NOMINAL RESISTANCE CURRENT (OHMS) 700 .058
NOMINAL POWER 7VA
PART NUMBER SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION
WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
PAGE 160
CLASS
MDR
DIMENSION A
M35 AND M60 DIMENSIONS
M60A-ML60A M60B-ML60B M35A-ML35A M35B-ML35B 2.375 Max. (60.3) 5.06 Max. (128.52) 1.06 Max. (27) 3.250 Max. (82.6) 5.062 Max. (128.52) 1.812 Max. (46.0) 3.250 Max. (82.6) 5.062 Max. (128.52) 1.812 Max. (46) 1.50Max. * (38.1) 5.062 Max. (128.52) 1.937 Max. (49.2) 2.281Max. (57.9) 5.062 Max. (128.52) 2.781 Max. (70.6) 2.281 Max. (57.9) 5.062 Max. (128.52) 2.781 Max. (70.6) 2.312 Max. (58.7) 4.875 Max. (123.8) 0.937 Max. (23.8) 3.187 Max. (81.0) 4.875 Max. (123.8) 1.687 Max. (42.9) 3.187 Max. (81.0) 4.875 Max. (123.8) 1.687Max. (42.9) 1.375 Max. (34.9) 4.875 Max. (123.8) 1.875 Max. (47.6) 2.218 Max. (56.3) 4.875 Max. (123.8) 2.656 Max. (57.4) 2.218 Max. (56.3) 4.875 Max. (123.8) 2.656 Max. (67.4) * SPST-NC outline is not shown. The SPST-NC tube is positioned lower on the coil so Dimension A is lower, but the overall height remains the same.
1 POLE
2 POLE
B C D E F
3 POLE
3.12 (79.4) 2.28 (58)
G H J
DIMENSIONS SHOWN IN INCHES AND (MILLIMETERS)
CONTACTOR TERMINAL
CONTACTOR TERMINALS
D
.205 Dia. (5.2) 4 Holes
B COIL TERMINALS E
.180 Dia. (4.6) 2 Holes
A
COIL TERMINALS
1.93 (49.2)
2 POLE 35AMP OR 60 AMP
F
1.77 (45)
1 POLE 35AMP OR 60 AMP
1.62 (41.3)
C 1.187 (30.2) 2.0 (50.8)
3.50 (88.9)
2.06 (52.4)
2.312 (58.7)
2.312 (58.7)
3.75 (95.3) 3.12 2.75 (79.4)
(69.9) CONTACTOR TERMINAL
30
30
G
.205 Dia. (5.2) 6 Holes
COIL TERMINALS
1.93 (49.2)
H
3 POLE 35AMP OR 60 AMP
J
1.77 (45)
2.28 (58)
3.36 (85.5)
PAGE 161
WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
CLASS
35 AND 60 AMP MERCURY DISPLACEMENT RELAYS
CLASS WM35 and WM60
UL Listed File No. E52197
MDR
1 POLE Weight 13 Ozs., (370 Grams)
SWITCHES RESISTIVE, TUNGSTEN, AND MOTOR LOADS STAINLESS STEEL TUBE S HIGH INRUSH CAPACITY
RESISTIVE AMPS 35* 35* 35* 25 ** 35* 35* 16* 12* TUNGSTEN AMPS 35* 17 9 7 35* 35* 16* 12*
CONTACTOR RATINGS FOR M35A - M35B VOLTAGE 120VAC 240VAC 480VAC 600VAC 24VDC 48VDC 125VDC 250VDC PHASE 1O 3O 1O 3O 1O 3O 1O 3O DC DC DC DC HP 1O 3O 3* 5* 5* 7.5* 5* 10* 5* 10* 1/2 1/2 1/2 1/2 MOTOR AMPS 1O 3O 34 30 28 19 14 14 11.2 11 27 13.5 5.2 2.6
* UL and CSA Listed
** CSA only
2 POLE Weight 26 Ozs., (738 Grams)
CONTACTOR RATINGS FOR M60A - M60B VOLTAGE 120VAC 240VAC 480VAC 600VAC 24VDC 48VDC 125VDC 250VDC PHASE 1O 3O 1O 3O 1O 3O 1O 3O DC DC DC DC HP 1O 3O 3* 5* 5* 10* 7.5* 15* 7.5* 15* 3/4 3/4 3/4 3/4 MOTOR AMPS 1O 3O 34 30 28 28 21 21 16 17 39 19.5 7.4 3.7 RESISTIVE AMPS 60* 60* 60* 50 ** 60* 60* 40* 20* TUNGSTEN AMPS AMPS "B" (N.C.) "A" (N.O.) 45* 60* 22.5 30 11.2 15 9 12 50* 50* 50* 50* 40* 40* 20* 20*
* UL and CSA Listed ** CSA only SEE MDR GENERAL SPECIFICATIONS AND DIMENSIONS.
UP
3 POLE Weight 2Lbs. 6 ozs., (1078 Grams)
RECOMMENDED MOUNTING POSITION 10
COIL Measured @ 25C NOMINAL NOMINAL NOMINAL NOMINAL PART RESISINPUT CURRENT POWER NUMBERS TANCE VOLTAGE (AMPS) (OHMS) 1 POLE NORMALLY OPEN CONTACT WM35A-120A 700 7VA .058 120 VAC WM35A-240A 2,800 7VA .029 240VAC, 60HZ 220VAC, 50HZ WM35A-24D 186 3.5W .120 24VDC 2 POLE NORMALLY OPEN CONTACTS WM35AA-120A 218 16.5VA .135 120 VAC WM35AA-240A 1,200 16.5VA .063 240VAC, 60HZ 220VAC, 50HZ WM35AA-24D 98 6W .232 24VDC 3 POLE NORMALLY OPEN CONTACTS WM35AAA-120A 120 VAC 111 28VA .220 WM35AAA-240A 240VAC, 60HZ 430 28VA .117 220VAC, 50HZ WM35AAA-24D 24VDC 64 9W .375 1 POLE NORMALLY CLOSED CONTACT WM35B-120A 460 13VA .115 120VAC
COIL Measured @ 25C NOMINAL NOMINAL NOMINAL NOMINAL PART RESISINPUT CURRENT POWER NUMBERS TANCE VOLTAGE (AMPS) (OHMS) 1 POLE NORMALLY OPEN CONTACT WM60A-120A 700 7VA 120 VAC ..058 WM60A-240A 2,800 7VA 240VAC, 60HZ .029 220VAC, 50HZ WM60A-24D 186 3.5W 24VDC .120 2 POLE NORMALLY OPEN CONTACTS WM60AA-120A 120 VAC 218 16.5VA .135 WM60AA-240A 240VAC, 60HZ 1,200 16.5VA .063 220VAC, 50HZ WM60AA-24D 98 6W 24VDC .232 3 POLE NORMALLY OPEN CONTACTS WM60AAA-120A 120 VAC 111 28VA .220 WM60AAA-240A 240VAC, 60HZ 430 28VA .117 220VAC, 50HZ WM60AAA-24D 24VDC 64 9W .375 1 POLE NORMALLY CLOSED CONTACT WM60B-120A 460 13VA 120VAC .115
WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
PART NUMBER SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION
PAGE 162
CLASS
MDR
35 AND 60 AMP MERCURY DISPLACEMENT RELAYS
CLASS WML35 and WML60
UL Listed File No. E52197
RECOMMENDED FOR MUCH LONGER LIFE WHEN SWITCHING RESISTIVE AND TUNGSTEN LOADS. AVAILABLE FOR AC LOADS ONLY. NOT RECOMMENDED FOR SWITCHING DC LOADS.
UP
1 POLE Weight 13 Ozs., (370 Grams) 2 POLE Weight 26 Ozs., (738 Grams) RECOMMENDED MOUNTING POSITION 10 3 POLE Weight 2Lbs. 6 ozs., (1078Grams)
CONTACTOR RATINGS FOR ML35A - ML35B VOLTAGE 120VAC 240 VAC 480VAC 600VAC RESISTIVE AMPS 35* 35* 35* 25 ** TUNGSTEN AMPS 35* 17 9 7 ** CSA only
CONTACTOR RATINGS FOR ML60A - ML60B VOLTAGE 120VAC 240VAC 480VAC 600VAC RESISTIVE AMPS 60* 60* 60* 50 ** TUNGSTEN AMPS AMPS "B" (N.C.) "A" (N.O.) 45* 60* 22.5 30 11.2 15 9 12
* UL and CSA Listed
* UL and CSA Listed
** CSA only
COIL Measured @ 25C NOMINAL NOMINAL NOMINAL RESISCURRENT POWER TANCE (AMPS) (OHMS) 1 POLE NORMALLY OPEN CONTACT WML35A-120A 700 7VA ..058 120 VAC WML35A-240A 2,800 7VA .029 240VAC, 60HZ 220VAC, 50HZ 2 POLE NORMALLY OPEN CONTACTS PART NUMBERS NOMINAL INPUT VOLTAGE WML35AA-120A WML35AA-240A 218 .135 120 VAC 1,200 .063 240VAC, 60HZ 220VAC, 50HZ 3 POLE NORMALLY OPEN CONTACTS 111 430 .220 .117 16.5VA 16.5VA
COIL Measured @ 25C NOMINAL PART NOMINAL NOMINAL RESISNUMBERS CURRENT POWER TANCE (AMPS) (OHMS) 1 POLE NORMALLY OPEN CONTACT 120 VAC 700 7VA WML60A-120A ..058 240VAC, 60HZ 2,800 7VA WML60A-240A .029 220VAC, 50HZ 2 POLE NORMALLY OPEN CONTACTS NOMINAL INPUT VOLTAGE WML60AA-120A WML60AA-240A 120 VAC 240VAC, 60HZ 220VAC, 50HZ 218 1,200 16.5VA .135 16.5VA .063 . 28VA .220 28VA .117
3 POLE NORMALLY OPEN CONTACTS 28VA 28VA WML60AAA-120A 120 VAC WML60AAA-240A 240VAC, 60HZ 220VAC, 50HZ 111 430
WML35AAA-120A 120 VAC WML35AAA-240A 240VAC, 60HZ 220VAC, 50HZ
PART NUMBER SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION .
PAGE 163
WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
CLASS
100 AMP MERCURY DISPLACEMENT RELAYS
CLASS WM100
CAPABLE OF SWITCHING 100 AMP LOADS UP TO 480 VAC /48VDC
LOAD TERMINALS AWG #1 THRU #8 WIRE .187 Dia. (4.7) 2 Holes 5.87 Max. (149) 3.00 Max. (76.2) AVAILABLE IN 1 POLE N.O. CONTACTS ONLY.
UL Listed File No. E52197
MDR
1.87 (4.7)
UP
1.00 Max. (25.4)
2.09 Max. (53.0) 3.50 Max. (88.9) 3.37 Max. (85.59)
RECOMMENDED MOUNTING POSITION 10
SPECIFICATIONS FOR WM100 COIL 60 per minute max. Frequency of Operation: 80% of nominal voltage, Typ. AC & DC coils. Pull-in voltage: 78% of nominal voltage, typ. AC coils. Dropout voltage: 65% of nominal voltage, typ. DC coils. CONTACTS Mercury. Material: .,001 ohm Typical. Contact resistance: TIMING Operate (at nominal voltage): Dropout (at nominal voltage): DIELECTRIC STRENGTH Across open Contact: Coil to Contact: Contact to Frame: Coil to Frame: TEMPERATURE Operating: LIFE Mechanical (No load): Electrical (Rated load): MISCELLANEOUS Insulation Material: Terminals: Options: Weight:
50 Milliseconds typical. 100 Milliseconds typical.
2650 V rms. 2650 V rms. 2650 V rms. 2650 V rms. - 35C to + 60C Under continuous load. 5,000,000 Operations. 100,000 Operations. Class B - 130C. # 1 thru 8 AWG wire. Coil Voltages from 12VAC to 480VAC, 5VDC. thru 250VDC. Consult Factory. 15.87 ozs. 450 grams.
CONTACTOR RATINGS FOR M100 COIL Measured @ 25C NOMINAL NOMINAL NOMINAL NOMINAL RESISINPUT CURRENT POWER TANCE VOLTAGE (AMPS) (OHMS) POLE NORMALLY OPEN CONTACT 120 VAC 33VA .275 73.5 240VAC, 60HZ 33VA .138 300 220VAC, 50HZ 24VDC 10W .380 53 VOLTAGE 120VAC 240VAC 480VAC 600VAC 24VDC 48VDC 120VDC 250VDC RESISTIVE TUNGSTEN HORSEPOWER SINGLE PHASE AMPS AMPS 100 100 100 80* 100 100 80 40 100* 60 30* 24* 100 100 80 40 3 5 15 10* 1.5* 1.5* 1.5* 1.5*
PART NUMBERS 1 WM100A-120A WM100A-240A WM100A-24D
PART NUMBER SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION
WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957, DOCUMENT 100 PAGE 164
* NON UL RATING PART NUMBER SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION
SERIES
102,103
50 &100 AMP, 2-POLE LIGHTING CONTACTORS
The Series 102 and 103 are solenoid types utilizing a DC coils with a full wave bridge rectifiers which allows the device to operate from an AC supply. Coil power consumption is less than 10 watts for the series 102, less than 20 watts for the 103. The contacts are Double make type, each set capable of switching and continuously carrying at least 50 Amps for the series 102 and 100 Amps for the series 103 at up to 480 volts AC. The contactors are typically constructed and wired to be directly interchangeable with existing hour meter base with separate wire leads for connection to the controlling device. Because of their compact construction, these contactors can be adapted to retrofit almost any existing type. Contact our Factory for details.
WIRING DIAGRAM
6.0 .6) 2 (15
3.0 .2) (76
6.0 (152.6) 102JXX 103JXX
UP
VOLTAGE AC (60HZ) 120 240 VOLTAGE (DC) 30 AC CONTACT RATINGS RESISTIVE LOAD (AMPS) Series 102 Series 103 200 100 200 100 DC CONTACT RATING RESISTIVE LOAD (AMPS) 100 200
RECOMMENDED MOUNTING POSITION
UNITS WIRED FOR 50 & 100 AMP LAMP LOAD SERVICE GENERAL SPECIFICATIONS COIL Pull-in Voltage: Dropout Voltage: Max. allowed voltage: Coil Resistance: CONTACTS Contact Material: DC: 80% of nominal voltage measured at 25C 10% of nominal voltage or more @ 25C 110% of nominal voltage 10% Measured @ 25C Silver Cadmium Oxide. 60 mS Max. @ Nominal Voltage. 30 mS Max. @ Nominal Voltage.
Struthers-Dunn
ORDERING CODE Typical Type No.
TIMING Operate Time: Release Time:
102
JXX
-110D
Series 102 Screw Term., 50 Amp. 103 Screw Term., 100 Amp. Contact Arrangements JXX- 2 Pole D.M. N.O Coil Voltage DC: 6 to 220 (Add "D") AC, FULL WAVE RECTIFIED: 12 to 240 (Add "A") WATT HOUR METER BOX NOT SUPPLIED WITH 102/ 103 CONTACTOR.
DIELECTRIC STRENGTH All Mutually Insulated Points: 1500 V rms between all mutually Insulated current carrying parts and those parts to ground. Insulation Resistance: 500 VDC Exceeds 1000 Megohms. TEMPERATURE Temperature Rating: LIFE EXPECTANCY Mechanical: Electrical: -45C to +65C @ rated operation. 500,000 Operations no load 100,000 Operations @ Rated Load. Coil 102 - #8-32 103 - #8-32 Load Term. #1/4-20 #3/8-18
TERMINALS MISCELLANEOUS Mounting: Weight:
Wall Mounting.. 42 oz., 1.2 kg Grams>
PAGE 165
WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
SECTION
7
7
LATCHING, SEQUENCE AND STEPPER RELAYS 5 TO 30 AMPERES Page 166
Magnecraft
Struthers-Dunn
LATCHING RELAYS TO 10 AMP
RELAY SERIES 250ML 388ML/285 308 255
FEATURES
OCTAL 11 PIN PLUG-IN DUAL COIL LATCHING SELF-MAINTAINING SET AND RESET COILS MAINTAINS LAST POSITION WITHOUT POWER AC OR DC COILS
PERMANENT MAGNETIC LATCHING RELAY SINGLE OR DUAL COIL 3 WAY TERMINALS: SOLDER, 0.187" Q.C. OR PLUG IN. HIGH SENSITIVITY COILS AVAILABLE AC OR DC INPUT
PERMANENT MAGNETIC LATCHING RELAY 3 WAY TERMINALS: SOLDER, 0.187" Q.C. OR PLUG IN. AC OR DC INPUT
2 COIL MECHANICAL LATCHING. SINGLE LEVEL SOCKET WIRING CONTINUOUS DUTY COILS
BOTH COILS MAY BE NO FALSE TRANSFER ENERGIZED SIMULTAWITH 5 TIMES NOMINAL NEOUSLY WITHOUT VOLTAGE PULSE DAMAGE. 4PDT 10 AMPS @ 120, 1/3 HP 10AMPS @ /240, 1/2 HP 10 AMPS @ 28 VDC SPDT, 3PDT, OR UP TO 4 FORM A, OR FORM B . 30AMPS @ 120 CARRY 10A, BREAK 10A. 30AMPS @ /240 CARRY 10A, BREAK 5A. 30 AMPS @ 125 VDC CARRY 10A, BREAK 0.5A. SILVER CADMIUM OXIDE OR GOLD DIFFUSED 50 MILLIOHMS (INITIAL)
CONTACT DATA
CONTACT
CONFIGURATION:
DPDT 10 AMPS @ 120 VAC/ 30 VDC
DPDT 10 AMPS @ 120/240VAC 10 AMPS @ 28 VDC
MAXIMUM ALLOWABLE CONTACT LOAD:
CONTACT CONTACT
MATERIAL: RESISTANCE:
SILVER CADMIUM OXIDE GOLD FLASHED 100 MILLIOHMS (INITIAL)
SILVER CADMIUM OXIDE GOLD FLASHED 50 MILLIOHMS (INITIAL)
SILVER CADMIUM OXIDE 50 MILLIOHMS (INITIAL)
INSULATION CHARACTERISTICS
DIELECTRIC STRENGTH: 1500 V rms 24, 120, 240 12 , 24, 110 1500 V rms 120 12, 24 3.4VA 1.9 WATTS 1500 V rms 6 to 240 6 to 125 3.4 VA 1.2 -1.9 WATTS 1500 V rms 6 to 240 6 to 125 (250V WITH SERIES RESISTOR) 5 OP 3 RESET 1.8 OP 1.9 RESET
COIL DATA
AC - VOLTAGE: DC - VOLTAGE: POWER: VA,: (VAC) WATTS,: (VDC)
6 VA 1.64 WATTS
GENERAL DATA
AMBIENT TEMPERATURE OPERATIONAL: STORAGE: TIMING VALUES OPERATE: RELEASE: LIFE MECHANICAL: ELECTRICAL: - 45 C to + 70 C - 45 C to + 70 C - 45 C to + 70 C - 10 C to + 60 C
30 30
MILLISECONDS MILLISECONDS
25 ms AC/15 ms DC 25 ms AC/15 ms DC
25 ms AC/15 ms DC 25 ms AC/15 ms DC
25 MILLISECONDS 20 MILLISECONDS
10 MILLION OPERATIONS 100,000 OPERATIONS H W L 1.41 x 1.41 x 3.17 Pending
10 MILLION OPERATIONS 100,000 OPERATIONS H W L
10 MILLION OPERATIONS 100,000 OPERATIONS H W L 1.50 X 1.93 X 1.87
10 MILLION OPERATIONS 100,000 OPERATIONS H W L 2.62 X 1.46 X 4.56
DIMENSIONS APPROVALS
APPLICATION DATA:
1.40 X 1.53 X 1.90
C
US PAGE 173, 174 PAGE 175, 176
PAGE 169 PAGE 170
PAGE NUMBER: PAGE 167
PAGE 171, 172
WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
Magnecraft
Struthers-Dunn
LATCHING & STEPPING RELAYS
RELAY SERIES 88L& 88LCP 311 C85
FEATURES
OPEN STYLE OR ENCLOSED STYLE DUAL COIL, MECHANICAL LATCHING. UP TO 6 FORM "C", 3 POLES PER COIL AC 50/60HZ, & DC COILS AVAILABLE SOLDER TERMINALS OR 20 PIN OCTAL PLUG-IN
SEQUENCE (STEPPING) RELAY SINGLE COIL CONTINUOUS DUTY. CONTACT TRANSFER ON ENERGIZING OR DE-ENERGIZING STROKE OF RELAY SINGLE LEVEL SOCKET WIRING DPDT 5 AMPS @ 120VAC 5 AMPS @ 28 VDC 0.1 AMPS 125 VDC
HEAVY DUTY SEQUENCE RELAY POSITIVE ACTION SEQUENCING CAM FRONT CONNECTED TERMINALS ANY SEQUENCE UP TO 12 STEPS
CONTACT DATA
CONTACT
CONFIGURATION:
UP TO 6PDT 0AMP 120VAC 10AMP 240VAC 10 AMP 28VDC
DPST-NO or NC & 1SPST-NC 20AMP 120VAC 20AMP 240VAC 20 AMP 30VDC
MAXIMUM ALLOWABLE CONTACT LOAD:
CONTACT CONTACT
MATERIAL: RESISTANCE:
SILVER CADMIUM OXIDE 100 MILLIOHMS (INITIAL)
SILVER CADMIUM OXIDE 50 MILLIOHMS (INITIAL)
FINE SILVER 50 MILLIOHMS (INITIAL)
INSULATION CHARACTERISTICS
DIELECTRIC STRENGTH: 1500 V rms 120 12 6VA 2.5 1500 V rms 6 to 240 6 to 110-125 5VA 1.8 WATTS 1500 VAC 24 to 550 24 to 240
COIL DATA
AC - VOLTAGE: DC - VOLTAGE: POWER: VA,: (VAC) WATTS,: (VDC)
18VA 14 WATTS
GENERAL DATA
AMBIENT TEMPERATURE OPERATIONAL: STORAGE: TIMING VALUES OPERATE: RELEASE: LIFE MECHANICAL: ELECTRICAL: - 10 C to + 50 C (AC) - 10 C to + 60 C (DC) 25 MILLISECONDS 25 MILLISECONDS - 10 C to + 60 C - 45 C to + 65 C
35 MILLISECONDS 35 MILLISECONDS
50 MILLISECONDS 50 MILLISECONDS
5 MILLION OPERATIONS 100,000 OPERATIONS H W L 1.93 X 1.75X 2.87
5 MILLION OPERATIONS 100,000 OPERATIONS H W L 2.62 X 1.46X 3.406
500,000 OPERATIONS 100,000 OPERATIONS H W L 2.625 X 3.00 X 5.00
DIMENSIONS APPROVALS PAGE NUMBER
PAGE 177, 178
PAGE 179
PAGE 180 PAGE 168
WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
SEQUENCE & LATCHING RELAY APPLICATION NOTES
APPLICATION DATA
SEQUENCE APPLICATIONS CONTINUED: A typical example is remotely starting and stopping a conveyer from a single momentary push button. Several momentary push buttons might be wired in parallel to control the conveyer from a number of locations. Another common use for sequence relays is cascade starting of multiple HVAC or other high start-up load systems, to limit the high starting current. WHAT IS A LATCHING RELAY: Latch relays typically use a permanent magnet or mechanical catch to hold the contacts in their last energized position without the need for continued application of coil power. They are especially useful in applications where power must be conserved, such as a battery operated device, or where it is desirable to have a relay stay in one position if power is interrupted. They should not be used to control a device that could create a safety hazard if it were to restart after a power interruption. Mechanical latch relays are most often constructed in a way that will cause them to go to their operate position when the operate coil is energized regardless of whether the reset coil is energized or not. This "operate coil dominant" feature can be useful in applications where a relay should operate and release like a conventional relay unless a particular action takes place, at which time the release coil would drop out, latching the relay in the operate position. A pallet loader would be a good example of equipment which might utilize this type of operation. Magnetic latching relays are typically designed to be polarity sensitive. When voltage is momentarily applied to the coil with a predetermined polarity, the relay will operate. The relay will remain in the operate position after power is removed from the coil. A permanent magnetic is designed to hold the contacts in the operate position without the need for continued power to the coil. When the polarity is reversed, and momentarily applied to the coil, the armature will push away from the coil overcoming the holding affect of the permanent magnetic, causing the contacts to reset. Both single and dual wound coils use the same principle of operation.
WHAT IS A SEQUENCE RELAY: A Sequence relay is sometimes called an alternator, stepper, flip-flop, or impulse relay. The relay has the ability to open and close it's contacts in a preset sequence. All sequence relays use a ratchet or catch mechanism to cause their contacts to change state by repeated impulses to a single coil. Usually, but not always, one pulse will close a set of contacts, the next will open them, and so on back and forth. This alternating of open and closed states has many possible uses. A Sequence relay requires a pulsed voltage to the coil of approximately 50 milliseconds for each sequence to take place. When the coil is pulsed, the relay armature moves a lever that in turn rotates the ratchet and cams to the first position in the sequence. This position will remain as long as another pulse is not introduced to the coil. The relay is normally comprised of at least two sets of contacts to allow the contacts to alternate in combinations of open and closed states, with each pulse of voltage to the coil. One example of possible two pole combinations, would be where one pole remains open and the other pole is closed with the first pulse applied to the coil. The second pulse could then reverse the above sequence. The third pulse could have both poles closed and the fourth pulse could open both poles. The above example could also have other sequences, depending upon the amount of teeth in the ratchet and the amount of lobes on the cams. Figure 1 shows an example of how cam placement on the contact blades can change the position of the contacts as cams are rotated by the ratchet gear.
Cam 1 Open contact
Cam 2 Closed contact
FIGURE 1
SEQUENCE APPLICATIONS: Some typical applications for sequence relays is turning one device on and off from a single momentary contact. PAGE 169
WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
CLASS
DUAL COIL, 10 AMP LATCHING RELAYS
250 ML
MAGNETIC LATCHING RELAY WITH 11 PIN BASE. OPERATED BY PULSED INPUT AND MAINTAINS LAST POSITION. CONTACT ARRANGEMENT: DPDT
OUTLINE DIMENSIONS PENDING
2.89 Max. (73.4) 2.33 Max. (59.2) Dimensions are shown in Inch and (Millimeter).
250ML
11 PIN PLUG Artwork marking side
1.37 (34.79) 6 5 4
7 8 1.37 (34.79)
3 2 1 11 10
9
SPECIFICATIONS CLASS 250 ML COIL Operate Voltage:: Reset Voltage: Duty cycle @ nominal voltage: Coil resistance: Max. allowable voltage: See Table below. (Measured @ 25C) See table below. (Measured @ 25C) Dual coil are intermittent duty. 10 % measured @ 25 C 5 X nominal voltage with no false transfer of contacts during Operate or Reset pulse. Class "B" system (130C) per UL STD. 1446 Coil Insulation: Duration of Operate & reset pulse: 50 mS Minimum. 3/16" silver cadmium oxide, gold flashed. 50 milliohms maximum initial resistance at rated current 12 V @ 100 Milliamps 10 Amps @ 120/240 VAC, 28 VDC 1/3 Hp @ 120 VAC, 1/2 Hp @ 240 VAC. (AC) 30 mS Max. (DC) 20 mS Max. @ nominal voltage. (AC) 30 mS Max. (DC) 20 mS Max. @ nominal voltage. 1500 V rms 500 V rms 1500 V rms 1500 V rms 1,000 Megohms min. @ 500 VDC
HERMETICALLY SEALED VERSION AVAILABLE CONSULT FACTORY
CONTACTS Contact material: Contact resistance: Minimum Load: Contact Rating: TIMING Operate time: Release time: DIELECTRIC STRENGTH Contacts to coil: Across open contacts: Pole to pole: Contacts to frame: Insulation resistance:
WIRING DIAGRAM RESET (+)
5 4 6 7 8 9 2 1 11 10
(-)
3
TEMPERATURE Ambient Temperature (Operating): - 30C to +70C - 30C to +105C Non operating storage: SHOCK RESISTANCE Latched: VIBRATION RESISTANCE Operating: MISCELLANEOUS Enclosure: Insulation material: Operating Position: Weight: 10 G's,
(-)
(+)
OPERATE 5 G's, 10 Hz to 55 Hz Plastic dust cover with 11 pin octal base. Molded plastic Any 170 g ( approx.) Stock Part Numbers shown also available thru Stocking Distribution Coil Measured @ 25C
SEE SECTION 10 FOR MATING SOCKETS
NOMINAL OPERATE VOLTAGE VOLTAGE MIN. DC OPERATED COILS W250ML2CPX-6 12 VDC 8.4 VDC W250ML2CPX-7 24 VDC 16.7 VDC W250ML2CPX-8 110 VDC 77 VDC AC OPERATED COILS W250AML2CPX-8 24 VAC 19.2 VAC W250AML2CPX-9 120 VAC 96 VAC W250AML2CPX-9 240 VAC 192 VAC
PART NUMBERS
CROSS REFERENCE COIL RESET NOMINAL TO VOLTAGE RESISTANCE POWER IDEC ( EA. COIL) MIN. 8.4 VDC 16.7 VDC 77 VDC 19.2 VAC 96 VAC 192 VAC 88/88 350/350 4000/4000 52/52 1200/1200 3200/3200 1.64 W 1.64 W 1.64 W 6 VA 6 VA 6 VA RR2KP-U-DC12 RR2KP-U-DC24 RR2KP-U-DC110 RR2KP-U-AC24 RR2KP-U-AC120 RR2KP-U-AC240
WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
PAGE 170
CLASS
388ML/285
10 AMP MAGNETIC LATCH RELAY
CLASS 388ML/285
10 AMP MAGNETIC LATCH RELAY. SINGLE OR DUAL COIL LATCHING. 1/3HP @ 120VAC 1/2 HP @ 240VAC C
Recognized Component mark for Canada and the United States.
US
UL Recognized File No. E43641
OUTLINE DIMENSIONS
Dimensions shown are in "Inches" and (Millimeter)
1.53 Max. (38.8)
1.90Max. (48.4)
.187 x .020 (4.76 x 0.51) QC Terminals Typical 1 4 2 5 8 3 6 9
1.40Max. (35.5)
7
A .28 Typ. (7.1)
B
COIL Measured @ 25C CROSS REFERENCE COIL NOMINAL OPERATE RESET NOMINAL NOMINAL TO CONFIGUEQUIVALENT PART NUMBERS INPUT VOLTAGE VOLTAGE RESISPOWER POTTER & BRUMFIELD RATION TANCE VOLTAGE (Or Less) (Or Less) (OHMS) AC OPERATED, SINGLE COIL SINGLE 120 VAC 102 VAC 102 VAC 10,000 W388AMLCPX-9 KUL11A15S-120 285XBXC-120A 0.8VA DC OPERATED, SINGLE COIL W388MLCPX-6 SINGLE 12 VDC 9.0 VDC 9.0 VDC KUL11D15S-12 285XBXC-12D 120 1.2W SINGLE 24 VDC 18,0 VDC 18.0 VDC W388MLCPX-7 KUL11D15S-24 285XBXC-24D 470 1.2W DC OPERATED, DUAL COIL W388ML2CPX-6 DUAL KUL11D15D-12 285XBXCD-12D 12 VDC 9.0 VDC 9.0 VDC 88/88 1.64W DUAL W388ML2CPX-7 KUL11D15D-24 285XBXCD-24D 24 VDC 18.0 VDC 18.0 VDC 350/350 1.64W PART NUMBERS
STRUTHERS-DUNN
PART NUMBERS SHOWN AVAILABLE THRU STOCKING DISTRIBUTION
PAGE 171
WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
CLASS
10 AMP MAGNETIC LATCH RELAY
388ML/285
SPECIFICATIONS CLASS 388/285
COIL Pull-in Voltage: Duty Cycle (Nominal V) Pulse Duration Min. Max. allowed voltage: Coil Resistance: CONTACTS Contact Material: Contact configuration: Contact Rating TIMING Operate Time: (@ Nom. V) Release Time: (@ Nom. V) DIELECTRIC STRENGTH Across open contacts between current carrying parts to ground: Insulation Resistance: TEMPERATURE Temperature Rating: LIFE EXPECTANCY Mechanical: Electrical: MISCELLANEOUS Enclosure: Weight: AC: 85%, DC: 75% of nominal voltage measured at 25C Single coil are continuous duty dual coil are intermittent duty. 30 Milliseconds 5 x Nominal voltage with no false transfer of contacts during operate or reset pulse. 110% of nominal voltage 10% Measured @ 25C Silver Cadmium Oxide, Gold Flashed. DPDT, (3PDT available) 10 Amps @ 120/240VAC, 28VDC AC: 30 mS max., DC: 20 mS max. AC: 30 mS max., DC: 20 mS max. 500 V rms 1500 V rms 500 VDC Exceeds 1000 Megohms. AC: -45C to +70C @ Rated Operation. 10 Million Operations no load 100,000 Operations @ Rated Load. Clear polycarbonate 87 grams approx.
WIRING DIAGRAM
VIEWED FROM PIN END RESET 1 4 7 A 3 6 9 RESET B 1 4 7 COMMON 3 6 RESET 9 8 OPERATE B A 1 4 5 7 3 6
-
+
-
-
9 8+ A B OPERATE
+
-
+ OPERATE SINGLE COIL ( DC )
SINGLE COIL ( AC ) VIEWED FROM TERMINAL END
OPERATE DUAL COIL ( DC )
SEE SECTION 10 FOR MATING SOCKETS
WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
PAGE 172
SERIES
308
MAGNETIC LATCH 10 AMP, 4 POLE RELAY
The series 308 relay combines the basic features of the 284 series relay into a permanent magnet latch relay. It is available with a single wound AC or DC coil. To operate the single-wound DC coil, voltage of proper polarity is applied to the coil, and reset when the polarity is then reversed. For AC coils, power is applied through the operate diode or the reset diode to provide the required function.
OUTLINE DIMENSIONS
Dimensions shown are in INCHES and (millimeters)
1.50 (38.1) 1.31 (33.3)
0.218 (5.53)
MANUAL PUSH BUTTON ACTUATOR (OPTIONAL)
1.93 (49.0)
1.87 (47.4)
0.28 (7.11)
0.187 (4.74)
WIRING DIAGRAM
(VIEWED FROM TERMINAL END)
Struthers-Dunn
ORDERING CODE Typical Type No.
1 5 9
2 6
3 7
4 8 12 14
308 XDX C LMY -120A
Series 308 3 way terminals, Magnetic latch, 10 Amp, 4 pole Contact Arrangements XDX (4 Form "C") Construction Style Enclosed, 3 way terminals - CODE C Options 10 Amp contacts Standard - NO CODE Gold diffused contacts - CODE G Indicator Lamp - CODE L Manual Actuator - CODE M Printed Circuit Terminals - CODE T 5 Amp contacts (Silver) - CODE Y Coil Voltage AC: 6, 12, 24, 48, 120, 240 (Add "A") DC: 6, 12, 24, 48, 115, 125 (Add "D") Dual Coil Construction available. Consult Factory.
+
11 10 OPERATE
13
RESET SINGLE COIL DC OPERATED 1 5 9 13 2 6 10 3 7 11 4 8 12
+ -
OPERATE COMMON 14 RESET SINGLE COIL AC OPERATED
PAGE 173
WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
MAGNETIC LATCH 10 AMP, 4 POLE RELAY
SERIES
308
GENERAL SPECIFICATIONS
COIL Pull-in Voltage: Dropout Voltage: Max. allowed voltage: Coil Resistance: CONTACTS Contact Material: TIMING Operate Time: Release Time: AC: 85%, DC: 75% of nominal voltage measured at 25C 10% of nominal voltage or more @ 25C 110% of nominal voltage 10% Measured @ 25C Silver Cadmium Oxide. AC: 25mS, AC: 25mS, DC: 15mS @ nom. Voltage DC: 15mS @ nom. Voltage
DIELECTRIC STRENGTH All Mutually Insulated Points: 500 V rms across open contacts 1500 V rms between current carrying parts Insulation Resistance: 500 VDC Exceeds 1000 Megohms. TEMPERATURE Temperature Rating: LIFE EXPECTANCY Mechanical: Electrical: -45C to +70C @ Rated Operation. 10 Million Operations no load 100,000 Operations @ Rated Load. Clear polycarbonate 5.0 oz. approx..
MISCELLANEOUS Enclosure: Weight:
CONTACT RATINGS
LOAD Resistive Motor Load 80% pF. 30VDC 10A 120VAC 10A 1/3Hp 240VAC 10A 1/2Hp
Maximum total load for 4 pole relays is 30 Amps @ 120 VAC, 20 Amps @ 240 VAC.
COIL SPECIFICATIONS @ 25C
Nominal Voltage 6 12 24 48 120AC or 115-125DC 240AC* Resistance Resistance Ohms 10% Ohms 10% DC AC 3 30 12 120 48 480 1920 870 8200 4700 -* Current (MA) AC 560 230 115 31 12 DC 200 100 50 25 13-15 -* Power Consumption AC DC 3.4VA 1.2W 3.4VA 1.2W 3.4VA 1.2W 3.4VA 1.2W 3.4VA 1.9W 3.4VA 1.9W
NOTE: For 220 VDC to 250 VDC coils, use a 8,200 , 5 Watt resistor in series with 110 VDC to 125 VDC relay coils.
WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
PAGE 174
SERIES
B255
300 VOLT LATCHING PLUG-IN RELAYS
THE SERIES B255 IS A TWO COIL LATCHING VERSION OF THE GENERAL PURPOSE TYPE 219 RELAY. WHEN THE OPERATE COIL IS MOMENTARILY ENERGIZED, THE RELAY MECHANICALLY LATCHES IN THE ENERGIZED POSITION AND REMAINS IN THE ENERGIZED POSITION WITH THE POWER REMOVED FROM THECOIL. THE SECOND COIL WHEN MOMENTARLY ENERGIZED, PROVIDES ELECTRICAL RESET OF THE CONTACTS. ALL CONTACTS OPERATE FROM A COMMON ARMATURE TO PREVENT CONTACT OVERLAPPING. COILS ARE RATED FOR CONTINUOUS DUTY. NUCLEAR QUALIFIED VERSIONS ARE AVAILABLE. CONTACT THE FACTORY FOR DETAILS.
UL Recognized File No. E13224
R
R
OUTLINE DIMENSIONS
Dimensions shown Inch & (Millimeters)
3.75 (95.25) 4.56 (115.8) 1.468 (37.28)
LOCKING DEVICE
6
7
2.625 (66.67)
Struthers-Dunn
ORDERING CODE Typical Type No.
WIRING DIAGRAMS
(VIEWED FROM TERMINAL END)
B255 XCX
P LM 6
OPERATE RESET
B255XBXP (DPDT ) 1
Series B255 2 Coil Latch plug-in Contact Arrangements XBX DPDT XCX 3PDT ABX SPST-NO & 2 Form C BXB DPST-NO & 2 Form B Standard Features Polycarbonate Cover- CODE "P" Optional Features Indicator Lamp across both coils - CODE "L" Manual Actuator- CODE "M" Perm. Magnet Blowout- CODE "69" Coil Voltage Coil Voltages & Frequencies must be specified. Note: For time delay on energizing reset coil, specify 256 series in lieu of B255
TYPE
B255ABXP B255XBXP B255XCP B255BXBP
12
1
CONTACTS
DPDT + 1 NO DPDT 3PDT 2 NO + 2 NC
7 B255XCXP (3 PDT) 6
OPERATE RESET
12
1
SEE SECTION 10 FOR MATING SOCKETS
7 B255ABXP (DPDT + 1 N.O. ) 6
OPERATE RESET
12 B255BXBP (2 N.O. + 2 N.C. ) 1
OPERATE
6
RESET
1
DC RELAYS, 1.8 WATTS (2.5 W @ 125VDC) OPTIONS 130C Coil Coil Suppression Light & Actuator Fine Silver-Gold Diffused Bifurcated Contacts SUFFIX U V LM 33
7
12
7
12
PAGE 175
WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
300 VOLT LATCHING PLUG-IN RELAYS
GENERAL SPECIFICATIONS
COIL Pull-in, min. AC Pull-in min. DC Overvoltage, max. CONTACTS Contact Material: TIMING Operate Time: (operate coil) Release Time: (Reset coil energized) DIELECTRIC STRENGTH All Mutually Insulated Points: Insulation : TEMPERATURE Rated Operation: 85% of Nominal Voltage 80 % of Nominal Voltage 110% of nominal, voltage
SERIES
B255
Silver Cadmium Oxide, & Gold Diffused (Standard) 25 mS Max. @ Nominal Voltage. 20 mS Max. @ Nominal Voltage.
1500 V rms 1/4" over surface, 1/8" thru Air
-10C to +60C
LIFE EXPECTANCY Mechanical: Electrical: MISCELLANEOUS Enclosure: Weight:
10 Million Operations no load 100,000 Operations @ Rated Load. 500,000 Operations 1/2 Rated Load. Clear polycarbonate. 215 g (7.58 oz.) APPROX.
UL Recognized File No. E13224
R
R
COIL SPECIFICATIONS @ 25C *AC COIL, 50/60 HZ RESET COIL (3VA) OPERATE COIL (5VA) Nominal Resistance Coil Power Resistance Coil Power Ohms (mA) (mA) Voltage Ohms 10% 10% 1.10 3.0 6 840 800 4.20 14.5 12 256 410 15.5 52.0 24 150 200 540 1450 120 26.5 45.0 1815 5000 240 4.8 13.2 Current inrush on all AC coils is less than twice the listed milliamperes ratings as shown in the AC coil data table. *Currents shown in table measured at 60 Hz. DC COIL DATA RESET COIL 1.4W) Nominal Resistance Coil Power Voltage Ohms (mA) 10% 21.0 6 286 85.0 12 141 300 24 80 115/125 8000 14.4 OPERATE COIL (1.8W) Resistance Coil Power Ohms (mA) 10% 15.5 385 63.5 189 250 96.0 6200 20.0 DC relays, 1.8 Watts (2.5 W @ 125VDC) CONTACT RATINGS BREAK MAKE CARRY RESISTIVE INDUCTIVE
30A 30A 30A 30A 30A 10A 10A 10A 10A 10A 10A 10A 5A 10A 0.5A 10A 3A 1A 3A 0.1A
VOLTS
24 VDC 120 VAC 240 VAC 28 VDC 125 VDC
** For versions with suffix "69" Permanent Magnet Blowouts
125 VDC 125 VDC 250 VDC 250 VDC SM DM SM DM 30A 30A 30A 30A 10A 10A 10A 10A 1.5A 4A 0.5A 1.5A 0.5A 1.5A 150 mA 0.5A
**Relays with Code 69 feature ( Check with factory for UL & CSA Listing).
WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
PAGE 176
CLASS
88L
DUAL COIL, 10 AMP LATCHING RELAYS
CLASS 88L
OPEN STYLE DUAL COIL LATCHING RELAY RATED 10 AMPS
OUTLINE DIMENSIONS Dimensions shown Inchs & (Millimeters)
2.87 Max. (72.9)
1.37 Max. (34.8) 1.75 Max. (44.45)
NOTE: Applying a momentary pulse to that coil which was NOT LAST ENERGIZED, will cause a transfer of all contacts. The mechanical latch will maintain all contacts in the last transferred position even after the coil is deenergized or power is interrupted. Re-transfer of contacts can be accomplished by a momentary pulse to the other coil.
.156 Dia. (3.96)
1.00 Typ. (25.4) 2.37 Max. (60.2) 2.68 Max. (68.07)
1.93 Max, (49.0)
.130 (3.30)
.100 (2.54)
CLASS 88LCP
ENCLOSED STYLE DUAL COIL LATCHING RELAY RATED 10 AMPS
WIRING DIAGRAMS Shown from Pin End
2.375 (60.3)
11 7 9 10 13 8 12 6 14 54 15 16 2 20 17 3 18 1 19
3.562 (90.47)
1.75 (44.45)
20 Pin Octal Socket mates with Magnecraft chassis mount socket 70-454 or equivalent.
5PDT PART NUMBER 70-454, 20 PIN SOCKET AVAILABLE. CALL FACTORY FOR CURRENT QUOTE.
PAGE 177
WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
DUAL COIL, 10 AMP LATCHING RELAYS
CLASS
88L
SPECIFICATIONS CLASS 88L RELAYS
COIL Pull-in voltage: Coil resistance: Nominal power: Duty: 80% of nominal voltage or less. for DC coils 85% of nominal voltage or less for AC coils 50/60 Hz operation, Measured @ 25C 10 % measured @ 25 C 6VA for AC coils, 3 Watts for DC coils. Intermittent actuation. min. pulse time 50mS @ nominal voltage. Max. pulse time 2 Minutes for AC coils, 5 Minutes for DC coils. 3/16" silver cadmium oxide, gold flashed. 50 m max. initial resistance @ rated current 25 mS or less at nominal voltage. 25 mS or less at nominal Voltage. 1500 V rms 1000 V rms 1500 V rms 1500 V rms 1000 megohms min. 500 VDC -10C to +50C (AC), -10C to +60C (DC) -30C to 105C 5 G's 20 G's 5 G's, 10 Hz to 55 Hz 5 G's, 10 Hz to 55 Hz 6 holes, 5/32" dia.for mounting plate to flat surface or 20 pin style plug-in. Fiberglass melamine Open style are Solder type standard, will also accept Q.C. terminals size .110. (Amp "Faston" or equivalent) Enclosed styles have 20 nickel plated brass pins "See-through " clear, polycarbonate plastic. Any Open Style: 6-1/2 ozs. 184.3 grams approx.. Enclosed style: 8 ozs. 226.8 grams
CONTACTS Contact material: Contact resistance: TIMING Operate time: Release time: DIELECTRIC STRENGTH Contacts to coil: Across open contacts: Pole to pole Contacts to frame: Insulation resistance: TEMPERATURE Ambient Temperature (Operating): Non operating (storage): SHOCK RESISTANCE Operating: Non operating: VIBRATION RESISTANCE Operating Non operating: MISCELLANEOUS Mounting: Insulation material: Terminals Enclosure: Operating Position: Weight:.
COIL Measured at 25C CROSS REFERENCE CONTACT NOMINAL TO CONFIGU- NOMINAL RESISTANCE NOMINAL POWER POTTER & BRUMFIELD RATION VOLTAGE (OHMS) AC OPERATED, OPEN STYLE, SOLDER TERMINAL _ 4PDT 120 VAC KB-17AG-120 6 VA W88ALX-4 PART NUMBERS DC OPERATED, OPEN STYLE, SOLDER TERMINAL 50 4PDT 12 VDC 88LX-2 AC OPERATED, ENCLOSED 20 PIN OCTAL PLUG-IN _ 120 VAC 5PDT 88ALCPX-23 2.4W 6 VA KB-17DG-12 KBP-20AG-120
Stock Part Numbers shown below also available thru stocking distriubution Part Numbers without a "W" prefix are Non-Stock Relays . Other AC & DC coil voltages and contact combinations up to 6 poles are available on special order. Consult Factory
WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
PAGE 178
SERIES
A311
INDUSTRIAL PLUG-IN SEQUENCE (STEPPER), 5 AMP
The A311 Series Relay is a sequencing version of the 219 series general purpose relay. Contacts transfer on each Impulse to the coil. Models are available with contacts transferring when coil is energized or when de-energized. A double cam movement, one cam per snap switch, allows one or both contacts to be energized or de-energized with the cam rotating one half-step when the coil is energized and the other half step when the coil is de-energized assures reliable sequencing of the two SPDT snap switches. 2.625
(66.6)
2.593 (65.5) 3.406 (86.5)
LOCKING CLIP
.435 (11)
WIRING DIAGRAM Viewed from Pin Side
12 6
OPERATE
11 2
10 3
9 4
8 5
7 6
1
1
1.468 (37.2)
7 A311XBXP A311XBXPR * (DPDT )
12
UL Recognized File No. E7104
*Transfer on Release CONTACT RATINGS LOAD
Resistive Max. Inrush
COIL Pull-in, min. AC Pull-in min. DC Overvoltage, max. CONTACTS Contact Material:
GENERAL SPECIFICATIONS 85% of Nominal Voltage 80 % of Nominal Voltage 110% of nominal, voltage Silver Cadmium Oxide
120VAC
5A 12A
30VDC
5A 12A
115VDC
0.1A 0.25A
TIMING Operate Time: (operate coil) 35 mS Max. @ Nominal Voltage. Release Time: (Reset coil energized) 35 mS Max. @ Nominal Voltage. DIELECTRIC STRENGTH Across open Contacts: Between mutually insulated current carrying parts & those parts to ground: Insulation Resistance : TEMPERATURE Rated Operation: LIFE EXPECTANCY Mechanical: Electrical: MISCELLANEOUS Enclosure: Weight: 500 V rms 1500 V rms 1000 M min. @ 500 VDC -10C to +60C
Struthers-Dunn
ORDERING CODE Typical Type No.
A311 XBX P R L -120A
Series A311 Industrial plug-in , Sequence Relay, 5 Amp, DPDT Contact Arrangements XBX ( 2 Form C) Standard Features Plug-in with Polycarbonate Cover - CODE P Contact Transfer When coil is energized - NO CODE when coil is de-energized CODE R Options Indicator Lamp - CODE L Coil Suppression - CODE V Coil Voltage AC: 6, 12, 24, 120, 240 (Add "A") DC: 6, 12, 24, 48, 110-125 (Add "D")
5 Million Operations no load 100,000 Operations @ Rated Load. Clear polycarbonate. 190 g (6.70 oz.) approx.
COIL SPECIFICATIONS @ 25C AC COIL , 50/60Hz Nominal Resistance Voltage Ohms 10% 1.1 6 4.2 12 15.5 24 540 120 1815 240 DC COIL Nominal Voltage 6 12 24 48 110-125 Resistance Ohms 10% 15.5 63.5 250 970 6200
SEE SECTION 10 FOR MATING SOCKETS PAGE 179
NOTE: Relays with other coil characteristics may be supplied to meet specific application requirements. 250VDC operation may be obtained by wiring a 6,200 , 5 Watt resistor in series with the 110-125VDC coil. The resistor must be mounted external to the A311.
WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
SERIES
SCREW TERMINAL SEQUENCE RELAY, 20 AMP, 2 POLE
The C85 Series Relay is a base mounted, screw terminal, open style sequencing relay. This two pole relay has a single coil which operates a ratchet wheel. Control cams, on the ratchet wheel shaft, step from one position to the next on each Impulse to the coil. A 50 millisecond pulse will step the relay. Coils are for momentary duty only. The C85 may be supplied in any sequence up to 12 steps. Contacts are single throw.
C85
5.00 (127)
3.00 (76.2) 2.62 (66.5) 2.37 (60.1)
WIRING DIAGRAM
.312 (7.92)
4.37 (110.9)
.312 (7.92)
GENERAL SPECIFICATIONS
COIL Pull-in, min. AC Pull-in min. DC Overvoltage, max. CONTACTS Contact Material: 85% of Nominal Voltage 80 % of Nominal Voltage 110% of nominal, voltage Fine Silver
TIMING Operate Time: (operate coil) 50 mS Max. @ Nominal Voltage. Release Time: (Reset coil energized) 50 mS Max. @ Nominal Voltage. DIELECTRIC STRENGTH Across open Contacts: Between mutually insulated current carrying parts & those parts to ground: Insulation Resistance : TEMPERATURE Rated Operation: LIFE EXPECTANCY Mechanical: Electrical: MISCELLANEOUS Terminals: Mounting: Weight
STANDARD CONTACT SEQUENCES
1500 V rms 1500 V rms 1000 M min. @ 500 VDC -45C to +65C
STEP CONTACT A C85AXA CONTACT B CONTACT A C85BXX CONTACT B 0 = CONTACT OPEN
RELAY
1 2 3 4 (REPEAT) 0 X 0X X 0 X0 0 X 0X 0 X 0X X = CONTACT CLOSED
500,000 Operations no load 100,000 Operations @ Rated Load. # 10-32 Studs with Hardware 3 clearance holes for # 8 screws 325 g (11.46 oz.)
Struthers-Dunn
ORDERING CODE Typical Type No.
CONTACT RATINGS C85
AC DC
C85 AXA H3 -120A
24VAC
20A 20A
120VAC 240VAC
20A 1.0A 10A 0.25A
COIL SPECIFICATIONS @ 25C AC COIL , 50/60Hz Nominal Resistance Voltage Ohms 10% 27 24 771 120 110-125 3,290 240 14,700 440 22,000 550 DC COIL Nominal Voltage Resistance Ohms 10% 62 24 120 110-125 1,475 6,100 240 440 550
Series C85 Screw Terminal Sequence Relay, 20 Amp, 2 Pole Contact Arrangements AXA 1 S.B.-N.O. & 1 S.B.-N.C. BXX 2 S.B.-N.O. Options Open style construction - NO CODE Sheet Metal Housing (consult Factory) For Dimensions) -CODE H3 7, 9, 10, 11, 12 Tooth ratchet-Consult Factory Coil Voltage AC: 24, 120, 240, 440, 550 (Add "A") DC: 24,110-125, 240 (Add "D")
RATCHETS: 8 Tooth Standard. ( 7, 9, 10, 11, and 12 are Special Order). Consult Factory. Non-Standard Coils, Specify requirement, Consult Factory.
WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
PAGE 180
Page 181
SECTION
8
8
HIGH VOLTAGE ELECTROMECHANICAL AND REED RELAYS 5KV TO 10KV
Magnecraft
Struthers-Dunn
HI-VOLTAGE RELAYS 5KV TO 10KV
RELAY SERIES 158 102V 102HV
5000 V0LTS 5000 V0LTS FEATURES
SWITCHES LOADS UP TO 1KVA. @ 5000 VOLTS DESIGNED WITH A UNIQUE DOUBLE MAKE & BREAK CONTACT DESIGN WITH GAP OF 0.40". EXCELLENT HIGH VOLTAGE ARCOVER RESISTANCE BETWEEN CONTACTS. SOLDER TERMINAL DESIGN. EPOXY SEALED FOR EXTRA PROTECTION FROM HIGH VOLTAGE ARC- OVER CHASSIS MOUNTING WITH SOLDER TERMINALS. EXTRA WIDE SEPARATION BETWEEN COIL AND OUTPUT CONTACTS.
10,000 V0LTS
EPOXY SEALED FOR EXTRA PROTECTION FROM HIGH VOLTAGE ARC OVER CHASSIS MOUNTING WITH SOLDER TERMINALS. EXTRA WIDE SEPARATION BETWEEN COIL AND OUTPUT CONTACTS.
SWITCHES UP TO 10 MILLIAMP SWITCHES UP TO 5 MILLIAMP LOADS @ 10,000 V LOADS @ 5000 V SPST-NO SPST-NO
CONTACT DATA
CONTACT CONFIGURATION: SPDT-DB-DM MAXIMUM ALLOWABLE CONTACT LOAD: CAPACITANCE (No shield) Across open contacts: CONTACT MATERIAL: CONTACT RESISTANCE:
1 KVA, 5000 VDC 200 mA, 5000 V 1 Amp, 1000 V SILVER ALLOY GOLD FLASHED 100 MILLIOHMS (INITIAL)
50VA, 5000 VDC 10 mA 2.0 pf TUNGSTEN 200 MILLIOHMS (INITIAL)
50VA, 10,000 VDC 5 mA 2.0 pf TUNGSTEN 200 MILLIOHMS (INITIAL)
INSULATION CHARACTERISTICS
DIELECTRIC STRENGTH Across open contacts: Coil to ground: Between all mutually insulated points: 7,500 V rms & contacts to ground 3,000 V rms 8,500 V rms AVAILABLE 24 VDC 5 WATTS 6,000 VDC NOT AVAILABLE 6, 12, 24 VDC 500-580 mW 12,000 VDC NOT AVAILABLE 24 VDC 1.5 WATTS 6,000 VDC 12,000VDC
COIL DATA
AC - VOLTAGE: DC - VOLTAGE: WATTS,: (VDC)
GENERAL DATA
AMBIENT TEMPERATURE OPERATIONAL: STORAGE TIMING OPERATE: RELEASE: BOUNCE: SHOCK (Non-operating): VIBRATION: LIFE MECHANICAL: ELECTRICAL: - 40C to + 85 C -60C to + 105C 45 MILLISECONDS 20 MILLISECONDS 10 G's -11mS, 1/2 sinewave 10 G'S - 10 to 55 HZ 5 MILLION OPERATIONS 100,000 OPERATIONS H W L - 40C to + 85C (1 Form A) - 40C to + 40C (1 Form B) -60C to + 105C 3 MILLISECONDS 2 MILLISECONDS 2.0 MILLISECONDS 30 G's -11mS 1/2 sinewave 10 G's - 10 to 1000 HZ 10 MILLION OPERATIONS 1,000,000 OPERATIONS H W L - 40C to + 85 C -60C to + 105C 3 MILLISECONDS 2 MILLISECONDS 2 MILLISECONDS 30 G's - 11mS, 1/2 sinewave 10 G's -10 to 1000 HZ 10 MILLION OPERATIONS 1,000,000 OPERATIONS H W L
DIMENSIONS APPROVALS PAGE NUMBER
2.28 X 2.21 X 3.12
0.75 X .875 X 4.50
0.75 X .875 X .450
PAGE 183
PAGE 184
PAGE 184 PAGE 182
WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
CLASS
158
HIGH VOLTAGE SWITCHING RELAYS
CLASS 158
SPDT-DB-DM CONTACT CONFIGURATION SWITCHES LOADS UP TO 1KVA
SPECIFICATIONS CLASS 158
COIL Coil Dissipation: DC 5 Watts.
CONTACTS Contact Material: Silver alloy, Gold Flashed, 1/4" dia. Contact Configuration: SPDT-DB-DM Switching Voltage max.: 5000 VDC Contact Rating: 200 mA @ 5000 VDC 1 Amp @ 1000 VDC
DIELECTRIC STRENGTH Across open contacts: Contact to Coil: Contact to Frame: Insulation Resistance:
7500 V rms 8500 V rms 3000 V rms 500 VDC, Exceeds 100 M
OUTLINE DIMENSIONS
DIMENSIONS SHOWN ARE IN INCHES AND (MILLIMETERS)
TEMPERATURE Operating: LIFE EXPECTANCY Electrical: Mechanical: MISCELLANEOUS Mounting: Weight:
-40C to +85C
1.750 (44.45) 1.125 (28.58)
.196 ( 4.98) dia. 2 Holes
100,000 ( Rated Load) 5 Million Operations (No Load) Min.
Bracket with 2 Clearance holes 0.196 dia. 212.6 grams (7.48 oz.)
3.125 Max. (79.38)
WIRING DIAGRAM
VIEWED FROM PIN END
2.281 (56.34)
2.281 (57.94)
FIELD INSTALLABLE JUMPER WIRE
SPDT-DB-DM
SPDT
PART NUMBERS
Coil Measured at 25C CONTACT NOMINAL CONFIGURA- NOMINAL NOMINAL INPUT COIL TION VOLTAGE RESISTANCE POWER SPDT-DB-DM
W158HVX-1
24VDC
120
5 Watts
PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION.
PAGE 183
WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
CLASS
HIGH VOLTAGE SWITCHING RELAYS
CLASS 102V
EPOXY ENCAPSULATED HIGH VOLTAGE REED. SPST-NO TUNGSTEN CONTACTS SWITCHES LOADS UP 10 mA @ 5000 Volts DC
102V
CLASS 102HV
Same as above except: Switches 10,000 Volts with Loads up to 5 mA DC
OUTLINE DIMENSIONS
DIMENSIONS SHOWN ARE IN INCHES AND (MILLIMETERS)
4.50 (114.3) 4.12 (104.7) 0.875 (22.2) 3.40 (86.5) .156 dia. (3.9) 0.75 (19.0) 0.25 (6.35) 1.50 (38.1) Coil Terminals .125 x .025
.645 (16.3)
1.10 (27.9)
.125 0.28 (3.18) (7.1) 0.08 (2.03) DIA. Typical.
Do not hook wire heavier than #22 AWG. Excess stress on terminals could cause damage to internal components
PART NUMBERS
CONTACT NOMINAL CONFIGURAINPUT TION VOLTAGE
Coil Measured at 25C NOMINAL NOMINAL COIL POWER RESISTANCE
5,000 VOLTS NORMALLY OPEN 500 mW 70 W102VX-49 SPST-NO 6 VDC 580 mW 250 W102VX-50 SPST-NO 12 VDC 580 mW 1000 W102VX-51 SPST-NO 24 VDC 10,000 VOLTS NORMALLY OPEN 1.5 Watts 400 W102HVX-3 SPST-NO 24 VDC
PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION.
NOTE: Other voltages and contact combinations available. Contact Factory. Pull-in is measured at 75% of nominal voltage or less, at 25C Weight: 49.2 grams, (1.74 oz.)
WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
PAGE 184
Page 185
SECTION
9
9
SENSITIVE LOW INPUT POWER RELAYS 2 TO 5 AMPERES
Magnecraft
Struthers-Dunn
SENSITIVE RELAYS 2 TO 5 AMP
RELAY SERIES 112, 112PGF 67S 392 292
FEATURES
LOW POWER DESIGN REQUIRES AS LITTLE AS 11.4 mW or 51.7 mW OF DC COIL POWER. AVAILABLE WITH AC OR DC COILS. CAN WITHSTAND 5 TO 10 TIMES COIL RATING UP TO 300 VOLTS 219 STYLE PLUG-IN OR OPEN STYLE
SOLDER/PLUG-IN WITH A 3-38 UNC MOUNTING STUD. UP TO 4 POLES WITH STANDARD SILVER, GOLD OVERLAY CONTACTS CHASSIS OR PC STYLE SOCKETS. INDUSTRY STANDARD FOOTPRINTS. SPDT TO 4PDT
LOW POWER DC RELAY 125mW PER POLE.
LOW POWER DC RELAY 125 mW PER POLE
OPERATES OVER A 3 WAY SOLDER TERMIWIDE VOLTAGE RANGE. NALS, .187 Q.C./ PLUG-IN. OCTAL STYLE PLUG-IN OPERATES OVER A FITS STANDARD 8 OR 11 WIDE VOLTAGE RANGE. PIN OCTAL SOCKETS FITS STANDARD 283/388 STANDARD SOCKETS.
CONTACT DATA
CONTACT CONFIGURATION: SPDT, DPDT SPDT TO 3PDT SPDT TO DPDT 5 Amps @ 120/240 VAC, 28 VDC SILVER 50 MILLIOHMS (INITIAL) MAXIMUM ALLOWABLE CONTACT LOAD:
CONTACT CONTACT
MATERIAL: RESISTANCE:
2Amps @ 120 VAC 1 Amp @ 240 VAC 2 Amps @ 30 VDC FINE SILVER 50 MILLIOHMS (INITIAL)
3 AMP @ 120 VAC/30 VDC
5 Amps @ 120 VAC/30 VDC
SILVER, GOLD OVERLAY 50 MILLIOHMS (INITIAL)
SILVER 50 MILLIOHMS (INITIAL)
INSULATION CHARACTERISTICS
DIELECTRIC STRENGTH Across open contacts: Between all mutually insulated current carrying parts and those parts to ground: 500 V rms 1,500 V rms 1.0 to 225 0.08 to 21.0 mA 1 pole 0.2VA, 2 pole 1.0VA 1 pole 15mW, 2 pole 52mW 500 V rms 1,500 V rms NOT AVAILABLE 4.5 to 13.7 mA 85 to 200 mW 500 V rms 1,500 V rms NOT AVAILABLE 15 to 139 mA 11.1 to 35 mA 125 mW Per pole 500 V rms 1,500 V rms NOT AVAILABLE 15 to 139 mA 11.1 to 35 mA 125 mW Per pole
COIL DATA
AC - VOLTAGE: DC - CURRENT: POWER AC VA: MILLIWATTS DC:
GENERAL DATA
AMBIENT TEMPERATURE OPERATIONAL: TIMING OPERATE: RELEASE: LIFE MECHANICAL: ELECTRICAL: OPTIONS: - 45C to + 65 C 20 MILLISECONDS 20 MILLISECONDS 500,000 OPERATIONS 100,000 OPERATIONS Special Pick-up and Dropout adjustments. Series coils to 50 Amp. H W L - 55 C to + 70 C 18 MILLISECONDS 8 MILLISECONDS 10 MILLION OPERATIONS 100,000 OPERATIONS Up to 8PDT @ 50 mW per pole. P.C. Terminals, Bifurcated contacts. Epoxy H W L .735 X .1.158 X 1.20 - 45C to +70 C 20 MILLISECONDS 15 MILLISECONDS 10 MILLION OPERATIONS 100,000 OPERATIONS Indicator lamp (125 VDC only) Manual Actuator. - 45C to + 70 C 20 MILLISECONDS 15 MILLISECONDS 10 MILLION OPERATIONS 100,000 OPERATIONS Indicator lamp (125 VDC only) Manual Actuator. P.C. socket, Q.C. socket. Stud or bracket mount. Gold diffused contacts. H W L 2.813 X 1.37 X 1.37
DIMENSIONS APPROVALS PAGE NUMBER
H
W
L
3.62 X 1.46X 2.62
2.81 X .1.37 X 1.37
PAGE 187, 188
PAGE 189
PAGE 190
PAGE 191, 192 PAGE 186
WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
112, 112-PGF 2 AMP, LOW COIL POWER, 1 & 2 POLE PLUG-IN
The 112 and 112-PGF Series of very low coil power relays, perform the same function but differ in physical packaging and terminations. Each is available with SPDT or DPDT contact arrangements. The coils require as little as 11.4 mW or 51.7 mW of DC coil power respectively. All 112's are available with AC or DC coils. AC coils can withstand 5 times their minimum rating, while DC coils can withstand 10 times their minimum rating, up to 300 volts. One application for this relay is to detect high resistance grounds which could have low leakage current.
SERIES
OUTLINE DIMENSIONS
Dimensions are shown in INCHES and (MILLIMETERS)
WIRING DIAGRAMS Viewed from Pin end
112XAX-PGF (SPDT ) 6 1
Removable cover with top screw for field adjustment of pull-in.
2.625 (66.6)
2.593 (65.5) 3.406 (86.5)
7
12
112XBX-PGF (DPDT) 6 .435 (11) 7 12 1
LOCKING CLIP
12 1
11 2
10 3
9 4
8 5
7 6
1.468 (37.2)
112-PGF Relays have front removable covers. When cover is removed the relay can be adjusted without being plugged in.
0.10 Dia. x .435 (2.54 x 11) Typical of all Pin Dimensions
Struthers-Dunn
ORDERING CODE Typical Type No. Series A112 base mounted, low coil power, 1 Form "C" 112 Low coil power, 1 & 2 Form "C" plug-in , 2 Form "C" base mount. Contact Arrangements XAX-SPDT (use with A112 base mount or 112-PGF) XBX - DPDT AXX SPST-NO (use with A112 base mount or 112-PGF BXX- DPST-NO AXA - SPST-NO +SPST-NC Construction Style Base mounted open style - NO CODE Industrial Plug-in, Polycarbonate cover, front removable - CODE PGF Coil Voltage Because of the wide variety of coils, both voltage and current to choose from, specify as a separate item. OPTIONS (CONSULT FACTORY)
DIMENSIONS & WIRING DIAGRAMS Front View
A112XBXBase mounted open style (DPDT ) 2.125 (53.97) A112XAXBase mounted open style (SPDT ) 1.875 (47.62)
112 XBX PGF Specify Coil separately
2.125 (53.97) 2.625 (66.67)
1.375 (34.92)
.625 (15.87) 2.375 (60.32)
2.625 (66.67)
SEE SECTION 10 FOR MATING SOCKETS
PAGE 187
WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
SERIES
2 AMP, LOW COIL POWER, 1 & 2 POLE PLUG-IN 112, 112-PGF
GENERAL SPECIFICATIONS 112, 112-PGF
COIL Overvoltage, max. CONTACTS Contact Material: TIMING Operate Time: Release Time: DIELECTRIC STRENGTH Across open contacts: All Mutually Insulated current carrying parts to ground: TEMPERATURE Rated Operation: LIFE EXPECTANCY Mechanical: Electrical: MISCELLANEOUS Enclosure: Weight:
Approvals for A112XAX & XBX Only. UL Recognized File No. E7104
AC, 5 x min. voltage, DC, 10 x min. voltage (up to 300V) Fine Silver
20 mS Max. @ Nominal Voltage. 20 mS Max. @ Nominal Voltage.
500 V rms
1500 V rms
-45C to +65C
500,000 Operations no load 100,000 Operations @ Rated Load.
Clear polycarbonate. (112-PGF Only) 7.05 oz. (200 g) approx.
CONTACT RATINGS
LOAD
AC DC
OPERATING DATA: (All Types) Min. Voltage: Selected from coil tables Min. Current: Selected from coil tables Series Coils: Available for connection in series with loads up to 50 Amps for series 112, and 10 Amps for series 112-PGF.
30VDC
2A 2A
120VAC 240VAC
2A 0.25A 2A -
COIL SPECIFICATIONS Measured @ 25C TYPES A112XAX, 112XAXPGF
AC COILS, 50/60 HZ Minimum Minimum Impedance Voltage Milliamps Ohms
1.0 1.4 1.6 2.0 2.5 3.5 4.3 5.0 6.0 8.5 12.0 13.5 16. 20 23 33 43 55 67 87 103 130 146 168 225 177 143 116 91.0 74.0 52.5 41.5 38.0 31.5 23.0 19.0 15.7 11.8 9.65 7.65 6.00 4.66 3.85 2.98 2.25 1.93 1.53 1.22 0.95 0.74 6 9 13 22 34 60 100 130 190 370 630 860 1,350 2,070 3,000 6,500 9,230 14,300 22,500 38,500 53,000 85,000 120,600 177,000 300,000
TYPES 112XBX, 112XBXPGF
AC COILS, 50/60 HZ Minimum Minimum Impedance Ohms Voltage Milliamps
2.34 2.80 3.25 4.40 5.50 6.90 9.10 10.8 13.1 20.6 26.5 30.0 35.0 45.5 49.0 72.0 95.0 122 146 190 230 390 310 250 200 160 114 910 83.0 69.0 50.0 42.0 35.0 26.0 22.0 16.4 13.0 10.2 8.5 6.5 4.9 4.9 6 9 13 22 34 60 100 130 190 370 630 860 1,350 2,070 3,000 6,500 9,230 14,300 22,500 38,500 53,000
DC COILS Minimum Minimum Resistance Voltage Milliamps Ohms
0.08 0.10 0.12 0.15 0.19 0.25 0.30 0.39 0.49 0.62 0.78 0.95 1.30 1.60 2.00 2.50 3.20 3.90 4.80 6.40 8.00 9.70 11.7 16.0 21.0 145 117 95.0 73.0 60.0 43.0 33.0 31.0 26.0 18.8 15.5 12.8 9.70 7.90 6.30 4.90 3.80 3.15 2.43 1.84 1.58 1.25 1.00 0.84 0.61 0.55 0.84 1.26 2.10 3.10 5.80 9.00 12.5 19.0 33.0 50.0 74.0 129 197 312 504 840 1,220 1,990 3,450 5,050 7,700 11,700 19,000 34,000
DC COILS Minimum Minimum Resistance Voltage Milliamps Ohms
0.18 0.22 0.27 0.34 0.41 0.55 0.68 0.86 1.09 1.37 1.72 2.11 2.77 3.46 4.33 5.47 7.11 8.53 10.8 14.1 17.7 323 260 211 165 133 95.0 76.0 69.0 57.0 42.0 35.0 29.0 22.0 18.0 14.0 11.0 8.5 7.0 5.5 4.0 3.5 0.55 0.84 1.26 2.10 3.10 5.80 9.00 12.5 19.0 33.0 50.0 74.0 1219 197 312 504 840 1,220 1,990 3,450 5,050
WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
PAGE 188
CLASS
67S
3 AMP, LOW COIL POWER, 2 & 4 POLE PLUG-IN
UL RECOGNIZED FILE NO. E52197 TYPICAL CONTACT LIFE EXPECTANCY FOR SWITCHING RESISTIVE LOADS @ 25C Number of Operations Load Current 1.0A 0.5A 0.1A 1mA Load Voltage 28VDC/120VAC 28VDC/120VAC 6 VDC 6 VDC Tolerances .010 Inches Ultra sensitive 5 X 105 5 X 106 5 X 107 5 X 107 -
CLASS 67 TYPICAL TIMING VALUES POLES OPERATE TIME DPDT 012
4PDT
.014 .008
RELEASE TIME .008
Measured at Nominal Voltage @ 25C
"A"
DIMENSIONS
CONTACT CONFIGURATION
"A"
DIM. .978 (24.8) 1.156 (29.4)
1.20 Max. (30.3)
DPDT
4PDT
.094 (2.3)
.170 (4.3) Elongated Hole .100 x .040 ( 2 x .1) All Contact Terminals are .010 Thick all coil terminals are .018 Thick.
.200 Max. (5.1) 3-48UNC-2A Thd.
SPECIFICATIONS CLASS 67S
COIL Pickup voltage: Dropout voltage: Coil resistance: Maximum coil dissipation: Coil Temperature rise: Maximum coil temperature: 80% of nominal voltage or less. 10% of nominal or more. 10% measured @ 25C 2.2 watts @ 25C 30C per watt 105C DIELECTRIC STRENGTH Contact to coil: Across open contacts: Coil to frame: Contacts to frame: Insulation resistance: 1500 V rms 500 V rms 1000 V rms 1500 V rms 1000 megohms @ 25C & 50% R.H.
CONTACTS Contact material: Contact resistance:
Silver, Gold overlay 50 milliohms max. initial
TEMPERATURE Operating: Storage:
-55C to + 70C -55C to +105C
CAPACITANCE Between contacts: Contact to coil: Coil to frame:
2 pf, typ. 2 pf, typ. 30 pf, typ.
MISCELLANEOUS Enclosure Material: Operating Position: Mounting: Weight:
Polycarbonate see thru plastic cover. Any Socket or 3-48 UNC stud 0.77 to 1.4 oz. (22 to 40 grams)
CLASS 67 - DC OPERATED - ULTRA SENSITIVE - PLUG-IN STYLE WITH 3-48 UNC STUD. COIL Measured @ 25C CROSS REFERENCE CONTACT TO NOMINAL PULL-IN CONFIGU- POTTER & BRUMFIELD PULL-IN PART NUMBERS CONTACT NOMINAL INPUT RESISTANCE RATION MILLIAMPS DC WATTS RATING MILLIAMPS DC (OHMS) STANDARD CONTACTS W67SCSX-1 W67SCSX-2 W67SCSX-3 W67SCSX-6 W67SCSX-7 W67SCSX-8 3 AMPS 3 AMPS 3 AMPS 3 AMPS 3 AMPS 3 AMPS 9.4 mADC 6.4 mADC 4.5 mADC 13.7 mADC 9.1 mADC 6.5 mADC 1000 2500 5000 1000 2500 5000 9.2 mADC 6.3 mADC 4.4 mADC 13.5 mADC 8.9 mADC 6.3 mADC 85mW 100mW 100mW 200mW 200mW 200mW DPDT DPDT DPDT 4PDT 4PDT 4PDT R10SE1(X or Y)2-J1.0K R10SE1(X or Y)2-J2.5K R10SE1(X or Y)2-J5.0K R10SE1(X or Y)4-J1.0K R10SE1(X or Y)4-J2.5K R10SE1(X or Y)4-J5.0K
Part numbers shown also available thru Stocking Distribution. SEE SECTION 10 FOR MATING SOCKETS PAGE 189 WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
SENSITIVE PLUG-IN, 5 AMP, 1 - 3 POLES
The 392 series relay has been designed to operate at 125 Milliwatts per pole. Because of the coil sensitivity, the contacts are rated at 5 Amps. The Industry standard 8 pin octal plug is used with SPDT & DPDT contact configurations, and the 11 pin plug is used with 3PDT contact configurations. Silver contacts are standard on this 5 Amp Relay. OUTLINE DIMENSIONS
Dimensions are shown in INCHES and (MILLIMETERS).
SERIES
392
2.25 (57.1)
.40 (10.1)
.675 (17.1) 4 3
1.37 (34.9)
5
6
1.37 (34.9)
2 1 8
7
WIRING DIAGRAM
UL Recognized File No. E13224 VIEWED FROM PIN END
CONTACT RATINGS LOAD
Resistive
30VDC 120VAC
5A 5A
GENERAL SPECIFICATIONS 392
CONTACTS Contact Material: TIMING Operate Time: Release Time: Silver 20 mS Max. @ Nominal Voltage. 15 mS Max. @ Nominal Voltage. SPDT
DPDT
3PDT
DIELECTRIC STRENGTH Across open contacts: 500 V rms All Mutually Insulated current carrying parts to ground: 1500 V rms Insulation Resistance: 1000 Megohms min. 500 V TEMPERATURE Rated Operation: LIFE EXPECTANCY Mechanical: Electrical: MISCELLANEOUS Enclosure: Weight; -45C to +70C 10 Million Operations no load 100,000 Operations @ Rated Load. Clear polycarbonate 3-1/2 oz. (99.2 g approx.).
Struthers-Dunn
ORDERING CODE Typical Type No.
392 XBX 48P LM - 5.0M
COIL SPECIFICATIONS @ 25C DPDT Resistance SPDT 392XBX (Ohms) 392XAX mA Volts mA Volts
1,000 2,500 5,000 10,000 11.1 15-44 15.8 21-44 7.0 23-68 10.0 32-68 5.0 32-97 7.0 45-97 3.5 45-139 5.0 64-139
3PDT 392XCX mA Volts
19.3 25-44 12.0 39-68 8.5 55-97 6.0 77-139
NOTES: (1) Rates for continuous operation at 25C at voltages within listed ranges. (2) Must operate at min. currents listed. Specify current when ordering POWER CONSUMPTION: 125mW per pole @ currents listed in the coil table.
Series Series 392 enclosed plug-in, low power consumtion coil. Open Style (Consult Factory) Contact Arrangements XAX- SPDT XBX - DPDT XCX - 3PDT Construction Style Open Style: ( Consult Factory for mounting styles, special wiring etc.). Enclosed Plug-in - CODE 48P Options Indicator Lamp, (125 VDC coil only.see coil specifications) - CODE L Manual Actuator - CODE M Operating Current (DC Only) XAX: 11.1, 7.0, 5.0, 3.5 (Add M) XBX: 15.8, 10.0, 7.0, 5.0 (Add M) XCX: 19.3, 12.0, 8.5, 6.0 (Add M)
SEE SECTION 10 FOR MATING SOCKETS PAGE 190
WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
SERIES
292
SENSITIVE , 3-WAY TERMINALS, 5 AMP, 1 - 3 POLES
The 292 series relay has been designed to operate on 125 MILLIWATTS per pole. Because of this coil sensitivity, the contacts are rated at 5 Amps. The 3-way terminal design provides additional versatility in wiring. The 1 to 3 Form "C" contact configurations, are ideal for low current DC circuits that require up to a 5 Amp outputs. Silver contacts are standard on this 5 Amp Relay.
R
UL Recognized File No. E13224
OUTLINE DIMENSIONS
Dimensions shown are in INCHES and (MILLIMETERS) 2.50 (63.5) 2.90Max. (73.8) .187 x .020 (4.76 x 0.51) QC Terminals Typical
WIRING DIAGRAM
Viewed from terminal end 1 4 7 A 2 5 8 3 6 9 B 1 4 7 A 2 5 8 3 6 9 B
1.53 Max. .625 Typ.(38.8) (15.8) Top mount plate & Stud Manual Push Button .218 Actuator (5.56) .156 (3.9) 1.90Max. (48.4)
1 4 2 5 8 3 6 9 B
SPDT
DPDT
292XBX 2 5 8 3 6 9 B
292XAX 1 4 7 A
1.40Max. (35.5)
7 A
ENCLOSED STYLE Choice of 6-32 Stud or Tapped Core with anti-rotation tab. - OR 6-32 Stud with top mounting plate and 1/8" nominal length anti rotation tab.
ENCLOSED BRACKET MOUNT The Body dimensions for the Enclosed style Plug-in are the same as the Bracket Mount style.
.28 Typ. (7.1)
3PDT
292XCX CONTACT RATINGS LOAD
Resistive
Struthers-Dunn
GENERAL SPECIFICATIONS
CONTACTS Contact Material: TIMING Operate Time: Release Time: Silver 20 mS Max. @ Nominal Voltage. 15 mS Max. @ Nominal Voltage.
30VDC 120VAC 240VAC
5A 5A 5A
DIELECTRIC STRENGTH Across open contacts: 500 V rms All Mutually Insulated current carrying parts to ground: 1500 V rms Insulation Resistance: 1000 Megohms min. 500 V TEMPERATURE Rated Operation: LIFE EXPECTANCY Mechanical: Electrical: MISCELLANEOUS Enclosure: Weight: -45C to +70C 10 Million Operations no load 100,000 Operations @ Rated Load. Clear polycarbonate. 3 oz. (85.05 g) approx..
ORDERING CODE Typical Type No.
292 XBX CS1
L - 10D
COIL SPECIFICATIONS @ 25C Resistance (Ohms)
1,000 2,500 5,000 10,000
SPDT 392XACX mA Volts
DPDT 392XBX mA Volts
3PDT 392XCX mA Volts
19.3 25-44 12.0 39-68 8.5 55-97 6.0 77-139
11.1 15-44 15.8 21-44 7.0 23-68 10.0 32-68 5.0 32-97 7.0 45-97 3.5 45-139 5.0 64-139
NOTES: (1) Rates for continuous operation at 25C at voltages within listed ranges. (2) Must operate at min. currents listed. Specify current when ordering POWER CONSUMPTION: 125mW per pole @ currents listed in the coil table.
Series Series 292 , 3-Way Terminals 125 Milliwatts per pole. Contact Arrangements XAX- SPDT (1 Form C) XBX - DPDT (2 Form C) XCX - 3PDT ( 2 Form C) Construction Style Open Style ( Consult Factory for mounting styles, special wiring etc.) Enclosed Plug-in - CODE C Enclosed Bracket Mount - CODE C1 Enclosed with 6-32 Side tapped hole- CODE C2 Enclosed Bracket Mount - CODE C! Enclosed with 6-32 side stud - CODE CS2 Options Gold Diffused Contacts - CODE G Indicator Lamp (125VDC Only) -CODE L Manual Actuator - CODE M Printed Circuit Terminals - CODE T Coil Current (DC Milliamps Only). XAX: 11.1, 7.0, 5.0, 3.5 (Add M) XBX: 15.8, 10.0, 7.0, 5.0 (Add mA) XCX: 19.3, 12.0, 8.5, 6.0 (Add mA)
SEE SECTION 10 FOR MATING SOCKETS
PAGE 191
WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
S E C T I O N 10
10
SOCKETS AND ACCESS0RIES Page 192
Magnecraft
Struthers-Dunn
SOCKET SELECTION GUIDE
FEATURES USE SOCKET NO. SOCKET NO. OF TERMINAL PART WITH OF NO. TYPES PINS RELAY POLES MOUNTING HOLDDOWN CLIP INCLUDED CLIP PART NO. APPROVALS: PAGE
UL
CSA
CE NO.
Octal base, 8 or 11 Pin socket. Panel or DIN rail mount with Screw Terminals & pressure plates. Fits all standard 8 & 11 pin octal plugs.
70-464-1
8
250 314
1, 2 3
Screw Screw
70-465-1 11
Panel or Not DIN Required Mount
None None
Yes Yes
Yes Yes
Yes
195
Yes
70-459-1 Class 78 Panel Mount/DIN rail mount with screw Terminals, Chassis mount with solder terminals or P.C. mount for direct solder to P.C. board. 70-461-1
8 14
78R 78
1, 2 4
Screw Screw
Panel or DIN Mt. Panel or DIN Mt. Chassis Chassis P.C. P.C.
No No
16-1197 16-1197
Yes Yes
Yes Yes
Yes Yes
196
70-401-1 70-378-1 70-402-1 70-379-1
8 14 8 14
78R 78 78R 78
1, 2 4 1, 2 4
Solder Solder P.C. P.C.
No No No No
16-1197 16-1197 16-1197 16-1197
Yes Yes Yes Yes
Yes Yes
Yes Yes
197
Yes Yes Yes Yes 198
Class 388 & 283 Square Base 11 pin Panel/DIN rail Mount, with Screw Terminals.
70-463-1
11
235, 236, 388
1, 2 3
Screw
Panel or DIN Mount
No
16-1278 or 16-1239 Long Body
Yes
Yes
Yes
199
Class 388 & 283 Square Base Socket for blade style relays. Solder/ Plug-in, Quick connect or Printed Circuit terminals. P.C. Socket without mounting ears 70-178-2
70-124-1 70-124-2 70-178-1 70-178-2
11
235, 236, or 388,
1, 2 or 3
Solder, Chassis 3/16" Q.C. Chassis P.C. PC P.C. P.C.
No No No No
16-722-2 16-722-2 16-722-2 16-722-2
Yes Yes Yes Yes
Yes Yes Yes Yes Yes Yes Yes Yes
200
219 Style Front connected wiring on one level with Screw Terminals. Mating relays have Locking Clip that mates with clip receiver in socket. All Sockets are supplied with insulated backing plate. Fits 12 pin 219 style relays.
27390
12
219 T219 246, 247 B255, A311 349, 112-PGF RSX1800 101-112 RRX164
2 to 5 Pole
Screw
Panel
No
None
Yes
201
219 Style Front connected wiring on one level with Screw Terminals. Mating relays have Locking Clip that mates with clip receiver in socket. All Sockets are supplied with insulated backing plate. Fits 14 pin 219 style relays.
33377
14
219 14 Pin Versions
2 to 6 Pole
Screw
Panel
No
None
Yes
201
Class 76 Panel or DIN mount Socket. Screw Terminals with pressure plates
70-478-1 70-475-1
5 8
76EU
1 2
Screw
Panel or Din rail
No
16-1264
Yes
Yes
202
PAGE 193
WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
Magnecraft
HOLDDOWN CLIP INCLUDED
Struthers-Dunn
SOCKET SELECTION GUIDE
FEATURES USE NO. OF TERMINAL SOCKET NO. PART OF SOCKET POLES TYPES NO. PINS WITH RELAY MOUNTING CLIP PART NO. APPROVALS:
UL
CSA
CE
PAGE NO.
Class 67 Chassis Mount Socket has Solder terminals.
70-303-1 70-304-1 70-305-1 Printed Circuit Socket 70-306-1 pins are soldered directly to the P.C.Board. 70-307-1 All sockets have relay 70-308-1 grounding strip that 70-309-1 connects to stud on 70-310-1 plug-in style relays.
10 10 16 16 22 22 28 28
67
2 2 4 4 6 6 8 8
Solder P.C. Solder P.C. Solder P.C. Solder P.C.
Chassis P.C. Chassis P.C. Chassis P.C. Chassis P.C.
Yes Yes Yes Yes Yes Yes Yes Yes
16-875-1 16-875-1 16-875-2 16-875-2 16-875-3 16-875-3 16-1120-8 16-1120-8
No No No No No No No No
No No No No No No No No
No No No No No No No No
203 204
Class 97 Chassis Mount Socket with metal mounting flange.
70-312
10
97
2
Solder
Chassis
No
None
No
No
No
205
DIP P.C. style 14 Pin Socket. Fits 0.100 board spacing.
70-276
14
DIP
1 or 2
P.C.
P.C.
No
None
No
No
No
205
ACCESSORIES
DIN rail conversion kit for use on series 219 style sockets. 27390 (12 pin) and 33377 (14 pin)
CX-4092
DIN Rail
No
No
No
WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
PAGE 194
OCTAL
8 or 11 PIN SCREW TERMINAL SOCKETS
Compatible with European 35 mm DIN rail mounting. Time saving snap in installation. Non metallic spring mechanism eliminates mounting hardware. Pressure clamp screw terminals hold wires mechanically secure. Pressure clamp terminals provide excellent electrical connection. Terminals accept up to two # 12 AWG wires. One piece stamped metal interconnections. No welded or soldered connections. Fits all standard 8 and 11 pin relay plugs. Can also be surface mounted with 2 screws.
DESIGNED FOR PANEL OR DIN MOUNT RATED: 10 AMPS, 300V MOLDED BASE, BREAK RESISTANT BLACK THERMOPLASTIC WITH CLOSED BACK.
C
E70550
US
Recognized to Canadian safety requirements under the Component Recognition Program of Underwriters Laboratories Inc.
70-464-1 PANEL/DIN MOUNT SOCKET Struthers-Dunn Equivalent Part Number 75224
WIRING DIAGRAMS
3PDT
1 2 11 10 9
D IN R A IL
70-465-1 PANEL/DIN MOUNT SOCKET Struthers-Dunn Equivalent Part Number 75225
.165 Dia. Mounting Hole (2 Places) 2.33
6-32 x .312 Combination Head Screw & Pressure Clamp (11 Places)
PART NUMBERS 70-464-1 70-465-1
Part Numbers shown also available thru Stocking Distribution Cross Reference reflects compatibility with relay foot prints. Shape, mounting, method of relay hold down, and socket internal wiring can vary. * Track mountable but not compatible with Magnecraft mounting hole locations.
PAGE 195
D IN R A IL
3 4 5 6
(59.1) 2.05 (52.07) .125 - .156 (3.17 - 3.96) 2.06 (52.3)
SPDT, DPDT
2 1 8 7
8 7 3 4 5 6
OUTLINE DIMENSIONS
Dimensions shown in Inches and (Millimeters) .165 Dia. Mounting Hole (2 Places)
1.60 Max. (40.6)
2.020 (51.3)
Tolerances: .010 (0.25) Unless otherwise shown.
.580 (14.73) .770 (19.56) .970 (24.6)
.150 (3.6)
.125 - .156 (3.17 - 3.96) .150 (3.6) 1.29 (32.7) .610 (15.5)
.830 6-32 x .312 Combination (21.08) Head Screw & Pressure Tolerances: .010 Clamp (11 Places) (0.25) Unless otherwise shown.
STYLE
WEIGHT (GRAMS)
P&B
IDEC
CROSS REFERENCE CUSTOM CONNECTOR OMRON OT08-PC OT11-PC PF083A-E PF113A-E*
ALLEN-BRADLEY GRAINGER 700-HN125 700-HN126 5X852 6X156*
8 Pin Octal Socket, Panel/DIN mount, Screw Terminals 11 Pin Octal Socket, Panel/DIN mount,, Screw Terminals
23.8 75
27E891 27E122 SR2P-06 27E892* 27E123 SR3P-06*
WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
CLASS
SCREW TERMINAL SOCKETS - 1, 2 & 4 POLE
Compatible with European 35 mm DIN rail mounting. Time saving snap in installation. Non metallic spring mechanism eliminates mounting hardware. Pressure clamp screw terminals hold wires mechanically secure. Pressure clamp terminals provide excellent electrical connection. Terminals accept up to two # 14 AWG wires for the 70-461-1, and up to #12 AWG wires for the 70-459-1 sockets. One piece stamped metal interconnections. No welded or soldered connections. Can also be surface mounted with 2 screws.
78
DESIGNED FOR PANEL OR DIN MOUNT 4 POLE: RATED 7 AMPS @ 300 VOLTS 1 & 2 POLE: RATED 10 AMPS @ 300 VOLTS
Recognized to Canadian safety requirements under the Component Recognition Program of Underwriters Laboratories Inc.
C
E70550
US
70-461-1 PANEL/DIN MOUNT SOCKET 16-1197 Spring Clip Ordered separately. Struthers-Dunn Equivalent Part Number 75228
.240 (6.10) Typ.
.197 .015 (5.0 0.4)
WEIGHT PART NO. OF SOCKET STYLE (GRAMS) NUMBERS POLES
70-459-1 70-461-1
PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION.
Cross Reference reflects compatibility with relay foot prints. Shape, mounting, method of relay hold down, and socket internal wiring can vary. * Panel mount ** Panel mount with grounding screw.
WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
D
Dimensions shown in Inches and (Millimeters)
1.210 (30.7) 1.015 (25.78) 1.275 (32.4)
IN R AI L
WIRING DIAGRAMS
4PDT
8 4 7 3 6 2 5 1
SPDT, DPDT
4 2 3 1
70-459-1 PANEL/DIN MOUNT SOCKET 16-1197 Spring Clip Ordered separately. Struthers-Dunn Equivalent Part Number 75227
D IN R AI L
8 14 13 9 6
7 5
1.18 (30) .156 (4.0)
OUTLINE DIMENSIONS
12 11 10
.315 (8.0)
1.080 (27.4)
.170 (4.3) 2.550 (64.8)
.160 (4.0)
2.65 (67.3) 1.325 (33.6)
.895 (22.7)
.785 (19.9)
Tolerances: .010 (0.25) Unless otherwise shown.
1.00 (2.54)
1.02 (26)
.800 (20.3)
Tolerances: .010 (0.25) Unless otherwise shown.
CROSS REFERENCE
P&B P&B IDEC CUSTOM CONNECTOR OMRON ALLEN-BRADLEY GRAINGER
1 or 2 4
Screw Terminal Screw terminal
49.8 42.8
27E895 27E894
27E487* SH2B-05 27E166** SY4S-05
GT08-15 MT14-PC
PTF08A-E PYF14A-E
700-HN116 700-HN128
2A582 2A584
PAGE 196
CLASS
78
CHASSIS MOUNT SOCKETS - 1, 2 & 4 POLE
Sockets fit Class 78 style relays. The sockets are chassis mounted and snap into panels up to .0625 (1.56) thick. The 4 pole socket has an additional receptacle and solder terminal for grounding 4 pole relays.
Recognized to Canadian safety requirements under the Component Recognition Program of Underwriters Laboratories Inc.
SOLDER TERMINALS SNAPS INTO CHASSIS 4 POLE: RATED 5 AMPS @ 300 VOLTS 1 & 2 POLE: RATED 10 AMPS @ 300 VOLTS
C
E70550
US
70-378-1 SOLDER TERMINAL SOCKET 16-1197 Spring Clip Ordered separately. Struthers-Dunn Equivalent Part Number 32884
70-401-1 SOLDER TERMINAL SOCKET 16-1197 Spring Clip Ordered separately. Struthers-Dunn Equivalent Part Number 40051
OUTLINE DIMENSIONS
Dimensions shown in Inches and (Millimeters)
.860 (21.84) .850 (21.59) .844 (21.44)
.860 (21.8) 1.150 (29.21)
R PA ECO NE M L C ME UT ND OU ED T
1.015 (25.78)
R PA ECO NE M L C ME UT ND OU ED T
1.015 (25.8)
1.158 .010 (29.41) .072 x .140 typ. (1.83 x 3.56)
.075 (1.90)
.750 (19.05)
.623 (15.82) Ground lug .105 (2.67)
SNAP FITS INTO CHASSIS .0625 (1.56) THICK
.075 (1.90) .440 (11.18) .770 (19.56)
.148 x .014 (3.75 x 0.355)
Tolerances: .010 (0.25) Unless otherwise shown.
.180 (4.57) Typ.
PART WEIGHT NO. OF SOCKET STYLE (GRAMS) NUMBERS POLES 70-401-1 70-378-1 1 or 2 4 Solder Terminal Solder Terminal 6.5 6.2
CROSS REFERENCE
P&B IDEC CUSTOM CONNECTOR OMRON ALLEN-BRADLEY
27E488 27E006
SH2B-51 SY4S-51
GR108-SLD MR14-SLD
PT08 PY14
700-HN117 700-HN104
PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION.
Cross Reference reflects compatibility with relay foot prints. Shape, mounting, method of relay hold down, can vary.
PAGE 197
WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
PRINTEDP.C. TERMINAL SOCKETS - 2 & 4 1, 2 & 4 POLE CIRCUIT TERMINAL SOCKETS - POLE
Sockets fit Class 78 style relays. The sockets are manufactured with "floating" (loose) P.C. terminals that allow the terminals to aline with holes in the circuit board without binding or bending to get correct fit and alignment of terminals. The 4 pole socket has an additional receptacle and solder terminal for grounding 4 pole relays.
Recognized to Canadian safety requirements under the Component Recognition Program of Underwriters Laboratories Inc.
CLASS CLASS
7878
PRINTED CIRCUIT TERMINALS 4 POLE: RATED 5 AMPS @ 300 VOLTS 1 & 2 POLE: RATED 10 AMPS @ 300 VOLTS
C
E70550
US
70-379-1 SOLDER TERMINAL SOCKET 16-1197 Spring Clip Ordered separately. Struthers-Dunn Equivalent Part Number 39830
70-402-1 SOLDER TERMINAL SOCKET 16-1197 Spring Clip Ordered separately. Struthers-Dunn Equivalent Part Number 41463
OUTLINE DIMENSIONS
Dimensions shown in Inches and (Millimeters) RECOMMENDED PRINTED CIRCUIT LAYOUT Viewed from component side
.350 (8.89) .160 (4.06) .410 (10.4) .660 (16.7) .175 (4.45) .850 (21.5)
RECOMMENDED PRINTED CIRCUIT LAYOUT Viewed from component side
.185 .844 .010 (21.44)
.598 (15.19) .024 (0.61) .145 (3.68) .262 (6.67)
1.150 (29.21)
.417 (10.5) .672 (17.07)
1.158 .010 (29.41)
.070 Dia. (1.78) 14 Places
.525 (13.34) .600 (15.24)
.623 (15.82) Ground Lug .440 (11.18) .060 Typ. (1.52) .140 x .014 (3.55 x 0.355)
.620 (15.7) .086 Dia. (2.18)
.394 (10.0) .440 (11.18) .672 (17.07) .078 Typ. (1.98)
.175 x .010 typ. (4.44 x .254)
Tolerances: .010 (0.25) Unless otherwise shown.
PART NO. OF SOCKET STYLE WEIGHT NUMBERS POLES (GRAMS) 70-402-1 70-379-1 1 or 2 4 Printed Circuit Printed Circuit 5.8 5.9
CROSS REFERENCE
P&B IDEC CUSTOM CONNECTOR OMRON ALLEN-BRADLEY GRAINGER
27E489 SH2B-62 27E031 SY4S-61
GR108-PCB MR14-PCB
PT08-0 PY14
700-HN118 700-HN105
2A583 -
PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION.
Cross Reference reflects compatibility with relay foot prints. Shape, mounting and method of relay hold down can vary.
WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
PAGE 198
CLASS
388 & 283
SCREW TERMINAL SOCKET - 1, 2 & 3 POLE
Compatible with European 35 mm DIN rail mounting. Time saving snap in installation. Non metallic spring mechanism eliminates mounting hardware. Pressure clamp screw terminals hold wire mechanically secure. Pressure clamp terminals provide excellent electrical connection. Terminals accept up to two # 12 AWG wires. Break resistant thermoplastic. One piece stamped metal interconnections. No welded or soldered connections. Can also be surface mounted with 2 screws. Recognized to Canadian safety requirements under the Component Recognition Program of Underwriters Laboratories Inc.
FITS SQUARE BASE .187 (3/16") BLADE STYLE RELAYS RATED: 15 AMPS, 300 VAC
C
E70550
US
Part Numbers shown also available thru Stocking Distribution
* Order Part Number 16-1278 Hold Down Clip for relays with a case height of 1.90" using 3/16" (.187) terminals
PAGE 199
D
Cross Reference reflects compatibility with relay foot prints. Shape, mounting, method of relay hold down, and socket internal wiring can vary.
IN
PART NUMBERS 70-463-1 *
R A
Struthers-Dunn Equivalent Part Number-75226 OUTLINE DIMENSIONS
DIMENSIONS ARE SHOWN IN INCHES AND (MILLIMETERS).
6-32 X .312 Combination Head Screw and pressure clamp 1.03 (26.1) .390 (9.9)
IL
70-463-1 PANEL/DIN SOCKET 16-1278 Spring Clip Ordered separately.
1.70 (43.1) 1.435 (36.4)
WIRING DIAGRAM TOP VIEW 4 6 5 3 2 1
3.00 (76.2)
B 9 8
A 7
1.57 (39.9) .150 Dia. (3.8) (2 Places
.150 Retaining notch for (3.81) hold down clip (2 Places)
Tolerances: .010 (0.25) Unless otherwise shown.
STYLE 11 Pin, Panel/DIN rail mount, with Screw Terminals
WEIGHT (GRAMS)
P&B
IDEC
CROSS REFERENCE CUSTOM CONNECTOR ALLEN-BRADLEY GRAINGER ST11-PC 700-HN127 5X853
50.6
27E893 SR3B-05
WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
SOLDER, Q.C. OR P.C. TERMINALS - 1, 2 & 3 POLE
Sockets fit Class square base style relays with 3/16" (.187) terminals. The quick connect, solder terminal and printed circuit sockets have mounting tabs for mounting to panels using two screws. The 70-178-2 Printed circuit socket has no mounting tabs
Recognized to Canadian safety requirements under the Component Recognition Program of Underwriters Laboratories Inc.
CLASS
388 & 283
FITS SQUARE BASE .187 (3/16") BLADE STYLE RELAYS RATED: 15 AMPS, 300 VAC
C
E70550
US
RECOMMENDED CHASSIS CUTOUT BOTTOM VIEW
1.39 (35.4)
RECOMMENDED PRINTED CIRCUIT BOARD LAYOUT BOTTOM VIEW
.391 (9.94) .875 (22.2) .437 (11.1)
16-722-2 Spring Clip Ordered separately. Struthers-Dunn Equivalent Part Numbers 36580 = 70-124-1 36581 = 70-124-2 36579 = 70-178-1
1.68 1.27 (42.7) (32.3)
1.68 (42.7) .611 (15.5) .287 (7.54) Drill 11 .078 (1.98) dia.holes for P.C. terminals
.829 (21.0)
OUTLINE DIMENSIONS
DIMENSIONS ARE SHOWN IN INCHES AND (MILLIMETERS).
.257 (6.53)
FIG. "A"
.500 typ (12.7) .125 (3.17)
.875 (22.2)
.205 (5.21) .156 (3.96Dia. (2 holes)
Drill two .156 (3.96) dia. holes for mounting Tabs.
Note: Holes not required when using Fig. "B" style socket
FIG. "B"
P.C. MOUNT
2.03 (51.6) 1.687 (42.85) 1.25 (31.75) 1.37 (34.8) 1.50 (38.1)
.218 (5.54) .875 (22.2) .540 (13.72) .165 Dia.(4.19) 2 holes
1.37 (34.8)
Connectors are Brass, Tin Plated.
1.50 (38.1) .130 Solder Terminal or .187 (3/16" Q.C. Terminal
.297 (7.5) .156 (3.96) Printed Circuit mounting
.297 (7.5)
.156 (3.96)
Tolerances: .010 (0.25) Unless otherwise shown.
Printed Circuit mounting with mounting Tabs
PART NUMBERS 70-124-1 70-124-2 70-178-1 70-178-2
FIG FIG "A" FIG "A" FIG "A" FIG "B"
STYLE .130 SOLDER TERMINAL 3/16" (.187) QUICK CONNECT PRINTED CIRCUIT, WITH TABS PRINTED CIRCUIT, NO TABS
WEIGHT (GRAMS)
12.1 12.1 9.4 9.4
CROSS REFERENCE CUSTOM CONNECTOR ALLEN-BRADLEY GRAINGER 27E043 SR3B-51 CM11-SLD 5X854 27E067 700-HN107 CM11-QDC 27E304 CM11-PCB CM11-PCB-1S P&B IDEC
Part Numbers shown also available thru Stocking Distribution Order Part Number 16-722-2 Hold Down Clip (Struthers-Dunn Equivalent 37067) for relays with a case height of 1.90 (48.2) Cross Reference reflects compatibility with relay foot prints. Shape, mounting and method of relay hold down can vary.
WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
PAGE 200
SERIES
219
SCREW TERMINAL SOCKETS
These Industrial style sockets offer front-connected wiring on one level with screw terminals accessible and numbered for ease in installation, wiring and checkout. Sockets are polarized. The mating relay has a locking clip that snaps into the socket, eliminating any need for external holding devices. All sockets are supplied with an insulating paper back plate for greater dielectric strength.
Recognized to Canadian safety requirements under the Component Recognition Program of Underwriters Laboratories Inc.
12 and 14 PIN PANEL MOUNT SOCKETS FIT ALL 219 STYLE RELAYS WITH 12 OR 14 PIN PLUGS. RATED: 10 AMPS, 600 VAC
C
E13224
US
E70550
UL LISTED WHEN USED WITH SERIES 219 RELAYS
27390 - 12 PIN PANEL MOUNT SOCKET OUTLINE DIMENSIONS
DIMENSIONS ARE SHOWN IN INCHES AND (MILLIMETERS). Tolerances: .010 (0.25) Unless otherwise shown.
33377 - 14 PIN PANEL MOUNT SOCKET
14 PIN SOCKET
3.10 (78.74) 1.687 (42.84) .484 (12.29)
12 PIN SOCKET
2.65 (67.3) 1.687 (42.84)
.484 (12.29)
.687 (17.4)
2.18 (55.3)
.687 (17.4)
2.18 (55.3)
6-32 screws 12 Places
.173 (4.39) mounting Holes 2 Places
6-32 screws 14 Places
.173 (4.39) mounting Holes 2 Places
.780 (19.8)
INSULATING PAPER BACK PLATE INSULATING PAPER BACK PLATE
.780 (19.8)
Struthers-Dunn
PART NUMBERS 27390 33377 STYLE 12 PIN SOCKET 14 PIN SOCKET WEIGHT CROSS REFERENCE (GRAMS) CUSTOM CONNECTOR SD12-PC 102 SD14-PC 120
Part Number Shown also Available thru Stocking distribution Notes: Insulating Back Plate Included with Socket When Sockets are mounted end to end, the distance between adjacent mounting holes should be 1" minimum.
PAGE 201
WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
CLASS
SCREW TERMINAL SOCKETS - 1 & 2 POLE
Compatible with European 35 mm DIN rail mounting. Time saving snap in installation. Pressure clamp screw terminals hold wires mechanically secure. Pressure clamp terminals provide excellent electrical connection. Terminals accept up to two # 14 AWG wires. One piece stamped metal interconnections. No welded or soldered connections. Fits all standard Class 76 relays Can also be surface mounted with 1 screw.
76
PANEL/DIN RAIL MOUNT. DIELECTRIC STRENGTH 1500 V rms, 1 MINUTE. RATED: 15 AMPS, 250 VAC.
OUTLINE DIMENSIONS
DIMENSIONS ARE SHOWN IN INCHES AND (MILLIMETERS).
SOCKET PART NO. (SPDT) 70-478-1
70-475-1 PANEL/DIN SOCKET 16-1321 Spring Clip Ordered separately.
.615 (15.6) .150 Dia. (3.81) SOCKET PART NO. (DPDT) 70-475-1 .615 (15.6) .153 (3.89) 1.25 (31.7) .150 Dia. (3.81)
.75 (19) 2.765 (70.23)
Tolerances: .010 (0.25) Unless otherwise shown.
1.02 (26)
PART NUMBERS
STYLE
WEIGHT CROSS REFERENCE (GRAMS) P&B IDEC 19.3 19.5 27E1038 27E1039 RP 78 604 RP 78 605
STANDARD FOOT PRINT FOR STYLE 76EURCPCXSPDT, Panel/DIN mount, Screw Terminal 70-478-1 DPDT, Panel/DIN mount, Screw terminal 70-475-1
Part Numbers Shown also Available thru Stocking distribution Cross Reference reflects compatibility with relay foot prints. Shape, mounting, method of relay hold down, and socket internal wiring can vary.
WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
PAGE 202
CLASS
67
SOLDER TERMINAL SOCKETS - 2 TO 8 POLE
Sockets fit Class 67 style relays with solder/plug-in terminals. All sockets have an grounding strip that connects with the mounting screw to the chassis. Contact material used is spring brass, tin plated. The body material is phenolic. Dielectric strength: 1000 V rms. Insulation Resistance 10 9 megohms
.210 (5.33)
CHASSIS MOUNT SOCKETS RATED: 10 AMPS MAX.
OUTLINE DIMENSIONS
DIMENSIONS ARE SHOWN IN INCHES AND (MILLIMETERS). Tolerances: .010 (0.25) Unless otherwise shown.
.210 (5.33)
70-303-1
2 POLE
.978 (24.8)
.350 (8.89)
70-307-1 6 POLE
1.390 (35.3) .350 (8.89)
16-875-1 Spring hold down Clip included
16-875-3 Spring hold down Clip included 70-305-1
.210 (5.33)
4 POLE
1.184 (30.1)
.350 (8.89)
70-309-1
.210 (5.33)
16-875-2 Spring hold down Clip included
8 POLE
1.596 (40.54)
.350 (8.89)
16-1120-8 Spring hold down Clip included
CHASSIS CUTOUT for panel mounting.
.281 (7.14) .281 .015 (7.14) 0.38 .354 (8.99)
"B"
CHASSIS CUTOUT DIMENSION "B"
.656 .015 (16.66) 0.38
CHASSIS MOUNT
SPDT DPDT 4PDT 6PDT 8PDT .343 .562 .781 1.00 (8.71) (14.3) (19.84) (25.4)
.140 (3.5)
.109 DIA. (2.77)
.090 X .045 (2.3 X 1.14) Elongated Holes .210 (5.33)
.750 (19.05) .350 (8.89)
USE 3-48 SCREW & NUT FOR MOUNTING SOCKET
GROUND STRIP FOR 3-48 UN-2A STUD
PART NUMBERS
NO. OF POLES 2 4 6 8
SOCKET STYLE Solder Terminal Solder Terminal Solder Terminal Solder Terminal
WEIGHT CROSS REFERENCE (GRAMS) POTTER-BRUMFIELD 4.3 5.5 6.9 8.5 27E125 27E126 27E127 27E211
70-303-1 70-305-1 70-307-1 70-309-1
PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION.
RELAY HOLD DOWN CLIP IS INCLUDED WITH ALL SOCKETS
PAGE 203
WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
P.C. TERMINAL SOCKETS - 2 TO 8 POLE
Sockets fit Class 67 style relays with solder/plug-in terminals. All sockets have an grounding strip that connects with the mounting screw to the chassis. Contact material used is spring brass, tin plated. The body material is phenolic. Dielectric strength: 1000 V rms. Insulation Resistance 10 9 megohms
CLASS
67
PRINTED CIRCUIT SOCKETS RATED: 10 AMPS MAX.
OUTLINE DIMENSIONS 70-304-1
.180 (457)
DIMENSIONS ARE SHOWN IN INCHES AND (MILLIMETERS). Tolerances: .010 (0.25) Unless otherwise shown.
2 POLE
.978 (24.8)
.350 (8.89) .180 (457)
16-875-1 Spring hold down Clip included
70-306-1
4 POLE
1.184 . (30.1)
.350 (8.89)
16-875-2 Spring hold down Clip included
.180 (4.57)
70-308-1
6 POLE
1.390 (35.3)
.350 (18.9)
16-875-3 Spring hold down Clip included
70-310-1
.180 (457)
8 POLE
1.596 (40.54)
.350 (8.89)
16-1120-8 Spring hold down Clip included SUGGESTED P.C. BOARD LAYOUT TOP VIEW (Component side of board)
.500 (12.70)
.750 (19.05)
.100 (2.54) GRID typical
8 Pole 6 Pole 4 Pole
USE 3-48 SCREW & NUT FOR MOUNTING SOCKET
GROUND STRIP FOR 3-48 UN-2A STUD
.500 (12.7)
2 Pole
.056 + .004 Dia. - .000 Holes (1.42 + .10) - .00
.450 (11.43)
.150 (3.81)
.100 (2.54)
NOTE: WHEN INSTALLING SOCKET(S) INTO A PRINTED CIRCUIT BOARD, USE PLUG-IN STYLE RELAYS FOR MAXIMUM TERMINAL CONTACT WITH MATING SOCKETS. PLUG-IN STYLE RELAYS HAVE A GROUNDING STUD AND ARE RECOMMENDED FOR USE WITH ALL SOCKET STYLES.
PART NUMBERS 70-304-1 70-306-1 70-308-1 70-310-1
NO. OF POLES 2 4 6 8
SOCKET STYLE WEIGHT (GRAMS) P.C. Terminal P.C. Terminal P.C. Terminal P.C. Terminal 4.3 5.5 6.9 8.5
CROSS REFERENCE POTTER-BRUMFIELD 27E128 27E129 27E130 27E254
PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION.
RELAY HOLD DOWN CLIP IS INCLUDED WITH ALL SOCKETS
WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
PAGE 204
CLASS
97
SOLDER TERMINAL SOCKET
CHASSIS MOUNT SOCKET ACCEPTS .250 CONTACT TERMINALS AND .110 COIL TERMINALS. Recommended RATED: 25 AMPS Chassis Layout
OUTLINE DIMENSIONS
DIMENSIONS ARE SHOWN IN INCHES AND (MILLIMETERS). Tolerances: .010 (0.25) Unless otherwise shown.
3 4 5 6
1.65 (41.9)
2.126 + .004
1.57 (39.8)
1 7 8 2 9 10
.175 .005 (4.44) .127) 2 Holes
1.65 (41.9)
2.12 (53.8) 2.50 (63.5)
70-312
.988 (25.09) .098 Dia. (2.48) (2 Places)
1.57 (39.8) .118 Dia. (2.99) (8 Places)
Part Number 70-312
STYLE 10 Contact socket, Chassis Mounted, Solder Terminal
WEIGHT (GRAMS) 48
Part Number Shown also Available thru Stocking distribution
CLASS
DIP
P.C. TERMINAL, DUAL INLINE SOCKET
DIP (DUAL INLINE PACKAGE) PHOSPHOR BRONZE CONTACTS, TIN PLATED THERMOPLASTIC POLYESTER BODY 0.100 GRID SPACING OUTLINE DIMENSIONS
DIMENSIONS ARE SHOWN IN INCHES AND (MILLIMETERS). Tolerances: .010 (0.25) Unless otherwise shown.
70-276
Equal Spacing at .100 Centers .396 (10.06) .696 (17.7) .200 (5.08)
Suggested Layout
Part Number 70-276
STYLE 14 Pin DIP Socket, 0.100 Pin Spacingl
WEIGHT (GRAMS) 1
.035 Dia, (.889)
0.100 Grid Pattern
.015 (.38) .130 (3.30) .025 x .008 Terminals (.63 x .20)
Part Number Shown also Available thru Stocking distribution
PAGE 205
WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
S E C T I O N 11
11
UTILIZATION CATEGORIES Page 206
UTILIZATION CATEGORIES FOR LOW VOLTAGE SWITCHGEAR AND CONTROL GEAR Nature of Category Current AC
AC-1 AC-2 AC-3 AC-4 AC-5a AC-5b AC-6a AC-6b AC-7a AC-7b AC-8a AC-8b
Typical Applications
Non-inductive or slightly inductive Loads, resistance furnaces Slip-ring motors: Starting, switching off. Squirrel-cage motors: Starting, switching off motors during running. Squirrel-cage motors: Starting, plugging 1), inching 2) Switching of electric discharge lamp control Switching of incandescent lamps. Switching of transformers Switching of capacitor banks. Slightly inductive loads in household appliances and similar applications. Motor-loads for household applications. Hermetic refrigerant compressor motor control with manual resetting of overload releases. Hermetic refrigerant compressor motor control with automatic resetting of overload releases. Control of resistive loads and solid state loads with isolation by optocouplers. Control of solid state loads with transformer isolation. Control of small electromagnetic loads. Control of A.C. electromagnetic loads. Connecting and disconnecting under no-load conditions, Switching of resistive loads, including moderate overloads. Switching of mixed resistive and inductive loads, including moderate overloads. Switching of motor loads or other highly inductive loads. Protection of circuits, with no rated short time withstand current Protection of circuits, with a rated short time withstand current Non-inductive or slightly inductive Loads, resistance furnaces Shunt-motors, Starting, plugging 1), inching 2), dynamic breaking of motors. Series-motors, Starting, plugging 1), inching 2), dynamic breaking of motors. Switching of incandescent lamps. Control of resistive loads and solid state loads with isolation by optocouplers. Control of DC electromagnets Control of DC electromagnetic loads having economy resistors in circuit. Connecting and disconnecting under no-load conditions Switching of resistive loads, including moderate overloads. Switching of mixed resistive and inductive loads, including moderate overloads (e.g. shunt motors) Switching of highly inductive loads (e.g. series motors).
Relevant I.E.C. Product Standard
947-4
AC-12 AC-13 AC-14 AC-15 AC-20 AC-21 AC-22 AC-23
947-5
947-3
AC and DC DC
A B DC-1 DC-3 DC-5 DC-6 DC-12 DC-13 DC-14 DC-20 DC-21 DC-22 DC-23
947-2
947-4
947-5
947-3
1) By plugging is understood stopping or reversing the motor rapidly by reversing motor primary connections while the motor is running. 2) By inching (jogging) is understood energizing a motor once or repeatedly for short periods to obtain small movements of the drive mechanism
PAGE 207
WEBSITE: www.magnecraft.com - EMAIL:info@magnecraft.com - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
CUSTOMER SERVICE STAFF & SUPPORT
Tel: 843/393-5778 Fax: 843/393-4123 Pricing Delivery Cross-Reference Return Authorization Order Entry Bill Moody Shelby Hall Natalie Campbell Beverly Streett Gaye Register Tel: 843/393-5421 Product Quality Jim Berg Les Wynne Application Engineering Assistance Bill Brady Tom Mahaffey Tel: 847/441-2531 Gene Piskorz Chuck Johnson Tel: 843/393-5421 Invoices Marjorie Bacote Customer Service Manager Sr. Customer Service Coord. Customer Service Coordinator Customer Service Coordinator Customer Service Coordinator Fax: 843/393-4123 Q.C. Manager MIL Spec. Solid State & Time Delay Relays Industrial Relays Fax: 847/4412522 Industrial Relays P.C. Relays Fax: 843/393-7843
Credit Manager
Magnecraft/Struthers-Dunn Our Goal
is an innovator and provider of quality relay products with a hands on commitment to staying close to customers worldwide. is to deliver defect-free products on time, all the time.
We Pledge
ourselves to achieve these goals in a manner which assures profitability and resources to support growth.
We Encourage
an atmosphere where diligence and hard work can exist in harmony with warmth, laughter, continuing education and personal development. We will conduct business in a way that encourages integrity in every employee, supplier and customer relationship.
Magnecraft
Struthers-Dunn
LIMITED WARRANTY
MAGNECRAFT ELECTRIC COMPANY/ MSD, Inc. warrants its product to be free of defects in workmanship and materials for a period of one year from date of delivery to the purchaser buying direct from MAGNECRAFT ELECTRIC COMPANY/ MSD, Inc. or authorized Distributor. This warranty includes, but is not limited to those products manufactured to specifications supplied to us by the purchaser. Any defects appearing more than one year from the date of delivery to the purchaser, shall be deemed to be due to ordinary wear and tear. MAGNECRAFT ELECTRIC COMPANY/ MSD, Inc. assumes no risk or liability for the suitability or unsuitability or results of the use of its products, used in combinations with any electrical or electronic components, circuits, systems, assemblies, or any other material or substances, or environments. The purchaser's right under this warranty shall consist solely of requiring MAGNECRAFT ELECTRIC COMPANY/ MSD, Inc. to repair, or in MAGNECRAFT'S/ MSD's sole discretion, replace, free of charge, F.O.B., factory, any defective items received at its factory within said year, as determined by MAGNECRAFT ELECTRIC COMPANY/ MSD, Inc. to be defective. All products to be returned to MAGNECRAFT ELECTRIC COMPANY/ MSD, Inc. for evaluation under this warranty, shall first receive a Return Authorization Number and Shipping Label from our Sales Department. All products shall be shipped to MAGNECRAFT ELECTRIC COMPANY/ MSD, Inc. prepaid. All products received at MAGNECRAFT ELECTRIC COMPANY/ MSD, Inc. without written authorization and return label, shall be returned at the sender's expense. The failure to give or the giving of any advice or recommendations by MAGNECRAFT ELECTRIC COMPANY/ MSD, Inc. shall not constitute any warranty by, or impose any liability upon MAGNECRAFT ELECTRIC COMPANY/ MSD, Inc. The sole and exclusive remedy of the purchaser and the exclusive liability of MAGNECRAFT ELECTRIC COMPANY/MSD, Inc. are outlined and stated above, AND IS IN LIEU OF ANY AND ALL OTHER WARRANTIES, EXPRESSED, IMPLIED, OR STATUTORY AS TO MERCHANTABILITY, FITNESS FOR PURPOSE SOLD, DESCRIPTION, QUALITY, PRODUCTIVENESS, OR ANY OTHER MATTER. In no event shall MAGNECRAFT ELECTRIC COMPANY/ MSD, Inc. be liable for consequential or special damages, or for the delay in the performance of this warranty.
MAGNECRAFT & STRUTHERS DUNN 700 ORANGE STREET DARLINGTON, SC. 29532-3739 TEL.: (843) 393-5778 FAX: (843) 393-4123 WEBSITE: www.magnecraft.com EMAIL: info@magnecraft.com
EUROPE MAGNECRAFT & STRUTHERS-DUNN OFFICE MUNICH FORSTENRIEDER ALLEE 227 .. D 81476 MUNCHEN / GERMANY TEL.: 4989 75080310 FAX: 4989 7558344
PRINTED IN U.S.A. 981015K
Magnecraft
Struthers-Dunn
LIMITED WARRANTY
MAGNECRAFT ELECTRIC COMPANY/ MSD, Inc. warrants its product to be free of defects in workmanship and materials for a period of one year from date of delivery to the purchaser buying direct from MAGNECRAFT ELECTRIC COMPANY/ MSD, Inc. or authorized Distributor. This warranty includes, but is not limited to those products manufactured to specifications supplied to us by the purchaser. Any defects appearing more than one year from the date of delivery to the purchaser, shall be deemed to be due to ordinary wear and tear. MAGNECRAFT ELECTRIC COMPANY/ MSD, Inc. assumes no risk or liability for the suitability or unsuitability or results of the use of its products, used in combinations with any electrical or electronic components, circuits, systems, assemblies, or any other material or substances, or environments. The purchaser's right under this warranty shall consist solely of requiring MAGNECRAFT ELECTRIC COMPANY/ MSD, Inc. to repair, or in MAGNECRAFT'S/ MSD's sole discretion, replace, free of charge, F.O.B., factory, any defective items received at its factory within said year, as determined by MAGNECRAFT ELECTRIC COMPANY/ MSD, Inc. to be defective. All products to be returned to MAGNECRAFT ELECTRIC COMPANY/ MSD, Inc. for evaluation under this warranty, shall first receive a Return Authorization Number and Shipping Label from our Sales Department. All products shall be shipped to MAGNECRAFT ELECTRIC COMPANY/ MSD, Inc. prepaid. All products received at MAGNECRAFT ELECTRIC COMPANY/ MSD, Inc. without written authorization and return label, shall be returned at the sender's expense. The failure to give or the giving of any advice or recommendations by MAGNECRAFT ELECTRIC COMPANY/ MSD, Inc. shall not constitute any warranty by, or impose any liability upon MAGNECRAFT ELECTRIC COMPANY/ MSD, Inc. The sole and exclusive remedy of the purchaser and the exclusive liability of MAGNECRAFT ELECTRIC COMPANY/MSD, Inc. are outlined and stated above, AND IS IN LIEU OF ANY AND ALL OTHER WARRANTIES, EXPRESSED, IMPLIED, OR STATUTORY AS TO MERCHANTABILITY, FITNESS FOR PURPOSE SOLD, DESCRIPTION, QUALITY, PRODUCTIVENESS, OR ANY OTHER MATTER. In no event shall MAGNECRAFT ELECTRIC COMPANY/ MSD, Inc. be liable for consequential or special damages, or for the delay in the performance of this warranty.
U.S.A. MAGNECRAFT & STRUTHERS DUNN 700 ORANGE STREET DARLINGTON, SC. 29532-3739 TEL.: (843) 393-5778 FAX: (843) 393-4123 WEBSITE: www.magnecraft.com EMAIL: info@magnecraft.com
EUROPE MAGNECRAFT & STRUTHERS-DUNN OFFICE MUNICH FORSTENRIEDER ALLEE 227 .. D 81476 MUNCHEN / GERMANY TEL.: 4989 75080310 FAX: 4989 7559344
PRINTED IN U.S.A. 981015K


▲Up To Search▲   

 
Price & Availability of W172DIP-147

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X