If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
Millivolt Output Pressure Sensors Features Package A * Temperature Compensated * Calibrated Zero and Span Applications Package M * Non Invasive Blood Pressure General Description This data sheet describes two package configuration of pressure sensors for use in non invasive blood pressure maeasurement. The output voltager is ratiometric to the supply voltage and is offered in either millivolt or amplified output configuration. 0.50 (12.7) B-port A-port Pin 1 2 3 4 0.10 Typical (2.54) 0.30 (7.6) pin 1: +V supply pin 2: Ground 0.62 (15.7) pin 3: +Voutput pin 4: -N/C 0.080 O.D. (2.00) 0.380 pin 1: N/C pin 2: +V supply pin 3: +Voutput pin 4: -Vsupply pin 5: -Voutput pin 6: N/C All Sensors DS-0048 Rev A a 16035 Vineyard Blvd. Morgan Hill, CA 95037 p 408 225 4314 f 408 225 2079 e www.allsensors.com all sensors Pressure Sensor Characteristics Maximum Ratings Supply Supply Voltage VS Proof Pressure Lead Temperature (soldering 2-4 sec.) see below 1500mmHg 250C Environmental Specifications Temperature Ranges Compensated Operating Storage Humidity Limits 10 to 50 C -25 to 85 C -40 to 125 C 0 to 95% RH (non condensing) Standard Package Types Part Number-Side Port BP01-D-MV BP01-G-4V-MINI Package Type A M Nominal Span 15 mV 4.2 volts Supply Voltage 5 volts 5 volts Performance Characteristics for BP01-D-MV Parameter, note 1 Operating Range, gage pressure Output Span, note 4 Offset Voltage @ zero pressure Offset Temperature Shift (10C-50C), note 2 Linearity, hysteresis error 0 - 200 mmHg, note 3 Linearity, hysteresis error 0 - 300 mmHg, note 3 Span Shift (10C-50C), note 2 14.85 Minimum Nominal 300 15.0 0 15.15 05 0.2 0.1 0.2 0.5 Maximum Units mmHg m V mmHg mmHg/C %fs %fs %fs Performance Characteristics for BP01-G-4V-MINI Parameter, note 1 Operating Range, gage pressure Output Span, note 4 Offset Voltage @ zero pressure Offset Temperature Shift (10C-50C), note 2 Linearity, hysteresis error 0 - 200 mmHg, note 3 Linearity, hysteresis error 0 - 300 mmHg, note 3 Span Shift (10C-50C), note 2 4.1 0.18 Minimum Nominal 300 4.2 0.25 4.3 0.32 0.2 0.1 0.2 0.5 Maximum Units mmHg V V mmHg/C %fs %fs %fs Specification Notes NOTE 1: ALL PARAMETERS ARE MEASURED AT ROOM TEMPERATURE UNLESS OTHERWISE SPECIFIED. PRESSURE MEASUREMENTS ARE WITH POSITIVE PRESSURE APPLIED TO NOTE NOTE NOTE 2: SHIFT IS RELATIVE TO 3: MEASURED AT ONE-HALF FULL SCALE 4: THE VOLTAGE ADDED TO THE OFFSET PORT B. 25C READINGS TAKEN AT 10C AND 50C. RATED PRESSURE USING BEST STRAIGHT LINE CURVE FIT. VOLTAGE AT FULL SCALE PRESSURE. All Sensors reserves the right to make changes to any products herein. All Sensors does not assume any liability arising out of the application or use of any product or circuit described herein, neither does it convey any license under its patent rights nor the rights of others. Blood Pressure Sensors |
Price & Availability of BP01-D1-MV
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |