 1GWJ42
TOSHIBA SCHOTTKY BARRIER RECTIFIER SCHOTTKY BARRIER TYPE
1GWJ42
HIGH SPEED RECTIFIER APPLICATIONS
* * * Average Forward Current: IF (AV)=1.0A (Ta=52C) Reverse Recovery Time: trr=35ns (MAX.) Low Forward Voltage: VFM=0.55V (MAX.) Unit: mm
MAXIMUM RATINGS (Ta = 25C)
CHARACTERISTIC Repetitive Peak Reverse Voltage Average Forward Current Peak One Cycle Surge Forward Current (Non-Repetitive) Junction Temparature Storage Temparature Range SYMBOL VRRM IF (AV) IFSM Tj Tstg RATING 40 1.0 40 (50Hz) -40~125 -40~125 UNIT V A A C C
JEDEC JEITA TOSHIBA
3-3E1A
Weight: 0.225 g (typ.)
MARKING
Part No. (or abbreviation code) Lot No. A line indicates lead (Pb)-free package or lead (Pb)-free finish. 1G WJ Abbreviation Code 1GWJ Part No. 1GWJ42
1
2004-08-10
1GWJ42
Handling Precaution
Schottky barrier diodes have reverse current characteristics compared to other diodes. There is a possibility SBD may cause thermal runaway when it is used under high temperature or high voltage. Please take forward and reverse loss into consideration during design. The maximum ratings denote the absolute maximum ratings, which are rated values and must not be exceeded during operation, even for an instant. The following are the general derating methods that we recommend when you design a circuit with a device. VRRM: Use this rating with reference to the above. VRRM has a temperature coefficient of 0.1%/C. Take this temperature coefficient into account designing a device at low temperature. We recommend that the worst case current be no greater than 80% of the maximum rating of IF(AV) and Tj be below 100C. When using this device, take the margin into consideration by using an allowable Tamax-IF(AV) curve. This rating specifies the non-repetitive peak current. This is only applied for an abnormal operation, which seldom occurs during the lifespan of the device. Derate this rating when using a device in order to ensure high reliability. We recommend that the device be used at a Tj of below 100C.
IF(AV):
IFSM:
Tj:
Thermal resistance between junction and ambient fluctuates depending on the device's mounting condition. When using a device, design a circuit board and a soldering land size to match the appropriate thermal resistance value. Please refer to the Rectifiers databook for further information.
2
2004-08-10
1GWJ42
ELECTRICAL CHARACTERISTICS (Ta = 25C)
CHARACTERISTIC Peak Forward Voltage Repetitive Peak Reverse Current Reverse Recovery Time Junction Capacitance Thermal Resistance (Junction to Ambient) Thermal Resistance (Junction to Lead) (Note 1) SYMBOL VFM IRRM trr Cj Rth (j-a) Rth (j-) TEST CONDITION IFM=1.0A VRRM=40V IF=1.0A, di / dt=-30A / s VR=10V, f=1MHz DC DC (Note 2) (Note 2) MIN TYP. 52 MAX 0.55 0.5 35 125 60 UNIT V mA ns pF C / W C / W
Note 1: trr TEST CIRCUIT
Note 2:
THERMAL RESISTANCE
tfr WAVEFORM
3
2004-08-10
1GWJ42
4
2004-08-10
1GWJ42
5
2004-08-10
1GWJ42
RESTRICTIONS ON PRODUCT USE
* The information contained herein is subject to change without notice.
030619EAA
* The information contained herein is presented only as a guide for the applications of our products. No responsibility is assumed by TOSHIBA for any infringements of patents or other rights of the third parties which may result from its use. No license is granted by implication or otherwise under any patent or patent rights of TOSHIBA or others. * TOSHIBA is continually working to improve the quality and reliability of its products. Nevertheless, semiconductor devices in general can malfunction or fail due to their inherent electrical sensitivity and vulnerability to physical stress. It is the responsibility of the buyer, when utilizing TOSHIBA products, to comply with the standards of safety in making a safe design for the entire system, and to avoid situations in which a malfunction or failure of such TOSHIBA products could cause loss of human life, bodily injury or damage to property. In developing your designs, please ensure that TOSHIBA products are used within specified operating ranges as set forth in the most recent TOSHIBA products specifications. Also, please keep in mind the precautions and conditions set forth in the "Handling Guide for Semiconductor Devices," or "TOSHIBA Semiconductor Reliability Handbook" etc.. * The TOSHIBA products listed in this document are intended for usage in general electronics applications (computer, personal equipment, office equipment, measuring equipment, industrial robotics, domestic appliances, etc.). These TOSHIBA products are neither intended nor warranted for usage in equipment that requires extraordinarily high quality and/or reliability or a malfunction or failure of which may cause loss of human life or bodily injury ("Unintended Usage"). Unintended Usage include atomic energy control instruments, airplane or spaceship instruments, transportation instruments, traffic signal instruments, combustion control instruments, medical instruments, all types of safety devices, etc.. Unintended Usage of TOSHIBA products listed in this document shall be made at the customer's own risk. * TOSHIBA products should not be embedded to the downstream products which are prohibited to be produced and sold, under any law and regulations.
6
2004-08-10


▲Up To Search▲   

 
Price & Availability of 1GWJ42Q

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X