Part Number Hot Search : 
MEDM2020 MPD400A NJU6679 GBL407 FAN6863R M5221 180CCP 1844F
Product Description
Full Text Search
 

To Download CE-150-1001 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 150 Watts
CE-150 Series
Features
* Universal 85-264 VAC Input * Harmonic Current per EN 61000-3-2 * Compact 4" X 7" X 1.75" Size * Standard "U" Shaped Chassis * Optional Perforated Cover * Optional Remote On/Off * Class B Conducted Emissions Per EN 55022,11 * EMC Compliant to EN 61000-4-2, 3, 4, 5, 6 & 11 and EN 60601-1-2 * Optional Power Fail Signal * 2 Year Warranty * EN 60950 ITE Certification * EN 60601-1 Medical Cert.
All specifications are maximum at 25C unless otherwise stated and are subject to change without notice.
Output Specifications
Total Output Power 100W Convection Cooled 125W Convection Cooled W/ 1 Sq. Ft. Baseplate 150W 300 LFM Forced Air Output 1: 0.25% Output 2: 0.25% (X0XX) (All Outputs Output 2: 3.0% (X1XX) 50% Load) Output 3: 2.0% Output 4: 2.0% Outputs 1-4: 0.5% Output 1: 0.5% (0-100% Load Change) Output 2: 0.5% (X0XX Models, 0-100%) 3.0% (X1XX Models, 10-100%) Output 3-4: 2.0% (0-100% Load Change) Output 2: 0.2% (X0XX) (Output 1 load Output 2: 5.0% (X1XX) varied 50-100%) Output 3-4: 2.0% Output 1-2: 95-105% (X0XX Models) Output 1: 95-105% (XIXX Models) Output 1: 85-105% (1001, 4001) Output 2: 85-105% (4002, 4003) 1% Outputs 1-4: 0.5% Outputs 1-4: 1% Outputs 1-4: 1% (Output under test at 100% rated load)
Output Voltage Centering
Source Regulation Load Regulation
Cross Regulation
Output Voltage Adjust Span Resolution Output Noise Source Freq. Switching Freq. Total (20MHz) Turn On Overshoot Transient Response Voltage Dev. Recovery Time Load Change Output Overvoltage Protection (Optional) Output Overpower Protection Output Overcurrent Protection Hold Up Time Start Up Time
MULTIPLE OUTPUT
SINGLE OUTPUT
Safety Specifications
General Protection Class: I Voltage Category: II Pollution Degree: 2 UL1950 Third Edition UL2601-1 Second Edition CB Report per IEC 950 (1991) Second Edition, A1, A2, A3, A4 All EN 60950 Deviations CB Report Per IEC 601-1 (1988) First Edition A1, A2 CAN/CSA-C22.2 No. 950-M95 CAN/CSA-C22.2 No. 601-1-M90 EN 60950/A4:1997 EN 60601-1/A2:1995 Low Voltage Directive
Underwriters Laboratories File E137708
None Outputs 1-4 5% 500 S 50% To 100% Output 1: 110% To 150% Shuts down all outputs. Cycle input to restart 165 Watts Min.,Outputs 1 and 2 Outputs cycle on/off, auto recovery 110% Min. Outputs 3 And 4 20 mS Min., 150W Output 120V Input 3 Seconds
UL Recognition Mark For Canada File E137708 TUV License B 98 05 30824 002
Input Specifications
Source Voltage Frequency Range Source Current True RMS Peak Inrush Peak Repetitive Harmonic Distortion Efficiency Power Factor 85 - 264 Volts AC 47-63 Hz 3A at 85V Input 30A 4.25A at 85V Input 0.05 .68 -.80 (Varies by model) 0.90 (150 watts, 230V)
Model Listing
MODEL CE-150-4001 CE-150-4002 CE-150-4003 CE-150-4004 CE-150-4005 CE-150-4006 CE-150-4007 CE-150-4101 CE-150-4102 CE-150-3001 CE-150-3002 CE-150-3003 CE-150-2001 CE-150-2002 CE-150-2003 CE-150-2101 CE-150-1001 CE-150-1002 CE-150-1003 CE-150-1004 CE-150-1005 CE-150-1006 CE-150-1007 OUTPUT 1 +3.3/15A +5V/15A +5V/15A +5V/15A +5V/15A +5V/15A +5V/15A +5V/15A +5V/15A +5V/15A +5V/15A +15V/5A +12V/7.5A +15V/5A +5V/15A +5V/15A 3.3V/30A (5) 5V/30A (5) 12V/12.5A 15V/10A 24V/6.25A 28V/5.4A 48V/3.1A OUTPUT 2 +5V/5A +3.3V/5A +3.3V/5A -5.2V/5A -5.2V/5A +12V/5A +12V/5A +24V/5A +24V/5A +12V/5A +15V/5A -15V/5A -12V/5A -15V/5A +12V/6A +24V/5A OUTPUT 3 OUTPUT 4 +12V/2A -12V/2A +12V/2A -12V/2A +15V/2A -15V/2A +12V/2A -12V/2A +15V/2A -15V/2A +12V/2A -12V/2A +15V/2A -15V/2A +12V/2A -12V/2A +15V/2A -15V/2A -12V/2A -15V/2A +5V/2A
Environmental Specifications
Ambient Operating Temperature Range Ambient Storage Temperature Range Temperature Coefficient Vibration Shock 0 C to +70 C Derating: See Power Rating Chart -40 C To +85 C Outputs 1-4: 0.02%/C MIL-STD-810E, Method 514.4 Category 1 Transit Drop per MIL-STD-810E Method 516.4 Procedure IV
General Specifications
Dielectric Strength 5656 VDC, Primary to Secondary, 1 Sec. 2121 VDC, Primary to Ground, 1 Sec. 500 VDC, Secondary to Ground, 1 Sec. <300 A Earth Leakage Current <100 A Patient Leakage Current Contact closure shuts off all outputs Logic low with input power failure 10 mS minimum prior to output one dropping 1% 250mV compensation of output cable losses 150,000 Hours min., MIL-HDBK-217F, 25 C, GB 2.0 Lbs.
Leakage Current Remote On/Off (Optional) Power Fail Signal (Optional) Remote Sense (Single Output Models Only) Mean-Time Between Failures Weight
Refer to "Applications Information" on page 17. Ph: (570) 824-4666 * Fx: (570) 824-4843
16
Electromagnetic compatibility specifications located on page 17.
CE-150 Series Mechanical Specifications
Electromagnetic Compatibility Specifications
Electrostatic Discharge Radiated Electromagnetic Field EFT/Bursts Surges Conducted Immunity Voltage Dips Voltage Interruptions Radiated Emissions Conducted Emissions Harmonic Current Emissions EN 61000-4-2 EN 61000-4-3 EN 61000-4-4 EN 61000-4-5 EN 61000-4-6 EN 61000-4-11 EN 61000-4-11 EN 55011 EN 55022 EN 55011 EN 55022 EN 61000-3-2 6kV Contact Discharge 3V/M, 26-1000 MHz 2kV 1kV Differential Mode 2 kV Common Mode 3V,150KHz-80MHz 30% Reduction, 10mS 60% Reduction, 100mS 95% Reduction, 5000mS Class B Class B Class B Class B
Applications Information
1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. Consult factory for alternate output configurations. Consult factory for positive, negative, or floating outputs. Specify optional overvoltage protection, remote on/off, power fail signal or cover when ordering. Each output can deliver its rated current but total output power must not exceed 100, 125 or 150 watts as determined by the cooling method. Rated 20 amps maximum when convection cooled only. Free air convection cooling, 100 watts maximum output power. Base plate cooled rating of 125 watts requires a one square foot .09" thick aluminum area attached to bottom four mounting holes. Forced air cooling rating of 150 watts requires an air speed of 300 linear feet per minute flowing past a point one inch above the main isolation transformer. This product is intended for use as a professionally installed component within medical and information technology equipment. A minimum load of 10% is required on output one to ensure proper regulation of remaining outputs. Remote sense terminals (Figure 1) may be used to compensate for cable losses up to 250mV (single output models only). The use of a twisted pair is recommended as well as a decoupling capacitor CD (0.1-10F) and a capacitor CL of 100F/Amp connected across the load side. Peak to peak output ripple and noise is measured directly at the output terminals of the power supply, without the use of the probe ground lead or retractable tip, 20 MHz bandwidth. This power supply has been safety approved and final tested using a DC dielectric strength test. Please consult factory before performing an AC dielectric strength test. The input circuit includes only one fuse in the "line" conductor. In consideration to paragraph 57.6 of UL 2601-1, when used in medical applications, a fuse should be added to the "neutral" conductor in the end product. Maximum screw penetration into chassis mounting holes is .250 inches.
12.
13.
AC Input Connector P1:
* .156 inch friction lock header mates with Molex 09-50-3031 or equivalent crimp terminal housing with Molex 08-50-0189 or equivalent crimp terminal.
14.
DC Output Connector P2: (Single Output)
* 6-32 screw down terminal mates with # 6 ring tongue terminal.
15.
DC Output Connector P2: (Multi Output)
* .156 inch friction lock header mates with Molex 09-50-3121 or equivalent crimp terminal housing with Molex 08-50-0189 or equivalent crimp terminal.
Maximum Output Power vs. Ambient Temperature
150 140 130 120 110 100 90 80 70 60 50 40 30 20 10 0 0 10 FORCED AIR COOLING BASEPLATE COOLING
Ground Connector
:
* Ground mates with .187 inch quick disconnect terminal.
Option/Sense Connector P3: (Single Output)
* .100 inch friction lock header mates with Molex 22-01-2067 or equivalent crimp terminal housing with Molex type 6459 or equivalent crimp terminal.
Output Power (Watts)
CONVECTION COOLING
Option/Sense Connector P3: (Multi Output)
* .100 inch friction lock header mates with Molex 22-01-2047 or equivalent crimp terminal housing with Molex type 6459 or equivalent crimp terminal.
20
30
40
50
60
70
Ambient Temperature, (C)
Optional cover increases height dimension from 1.75 to 1.92 inches. Figure 1 - Output sense connections
Ph: (570) 824-4666 * Fx: (570) 824-4843
17


▲Up To Search▲   

 
Price & Availability of CE-150-1001

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X