Filename: tfs 398h.doc Version 1.3 14.02.2007 VI TELEFILTER Measurement condition Ambient temperature: Input power level: Source and load impedances: Terminating impedance: * Input: Output: 23 0 200 C dBm Filter specification TFS 398H 1/5 320 || -4,6 pF 330 || -4,1 pF Characteristics Remark: The reference level for the relative attenuation arel of the TFS 398H is the minimum of the pass band attenuation. This value is defined as the insertion loss ae. The nominal frequency fN is fixed at 398 MHz without any tolerance. The values of relative attenuation arel are guaranteed for the whole operating temperature range. The frequency shift of the filter in the operating temperature range is included in the production tolerance scheme. Data Insertion loss (reference level) Nominal frequency Passband Pass band ripple Relative attenuation fN fN typ. value ae =amin fN PB p-p arel ... fN 16 MHz ... fN tolerance / limit max. 13,5 398 fN 10 0,2 dB dB MHz MHz dB 7,5 1 dB max. 7,5 50 MHz MHz 0,7 45 14 dB dB ns max. min. max. 1 40 60 dB dB ns Group delay ripple within PB Operating temperature range Storage temperature range Temperature coefficient of frequency TCf ** OTR -18 ppm/K - 40 C ... + 85 C - 40 C ... + 85 C - *) The terminating impedances depend on parasites and q-values of matching elements and the board used, and are to be understood as reference values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team. **) fc(Hz) = TCf(ppm/K) x (T - To) x fTo (MHz). Generated: Checked / Approved: Tele Filter GmbH Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 398h.doc Version 1.3 14.02.2007 VI TELEFILTER Filter characteristic 0 Filter specification TFS 398H 2/5 0 1.69 -6 -1 1.54 -12 -2 1.39 -18 -3 1.24 -24 magnitude in dB magnitude in dB -4 1.09 -30 -5 0.94 -36 -6 0.79 -42 -7 -48 0.64 -8 -54 0.49 -60 -9 0.34 348 358 368 378 388 398 408 frequency in MHz 418 428 438 448 -10 387 389.2 391.4 393.6 395.8 398 400.2 frequency in MHz 402.4 404.6 406.8 0.19 409 Construction and pin connection (All dimensions in mm) 1 2 3 4 5 6 7 8 Date code 7 5 398H V07 1 3 1,8 Max. Input Input Ground Ground Output Output Ground Ground 1 5 - 0,10 + 0,15 3 1,1 2,54 200 Ohm Test circuit 0,1 7 5 1,1 Date code: V W X ... Year + week 2007 2008 2009 120 0,64 1 L1 C1 L2 5 L3 2 SAW 6 L4 C2 3, 4, 7, 8 Tele Filter GmbH Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. delay in s Filename: tfs 398h.doc Version 1.3 14.02.2007 VI TELEFILTER Stability characteristics, reliability Filter specification TFS 398H 3/5 After the following tests the filter shall meet the whole specification: 1. Shock: 2. Vibration: 3. Change of temperature: 4. Resistance to solder heat (reflow): 500g, 1 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 10 Hz to 500 Hz, 0,35 mm or 5 g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 -55 C to 125C / 30 min. each / 10 cycles DIN IEC 68 part 2 - 14 Test N reflow possible: three times max.; for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4; This filter is RoHS compliant (2002/95/EG, 2005/618/EG) Packing Tape & Reel: IEC 286 - 3, with exception of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters per reel: reel of empty components at start: reel of empty components at start including leader: trailer: Pull Off Direction 3000 min. 300 mm min. 500 mm min. 300 mm Tape (all dimensions in mm) W : 12,00 0,3 Po : 4,00 0,1 Do : 1,50 +0,1/-0 E : 1,75 0,1 F : 5,50 0,05 G(min) : 0,75 P2 : 2,00 0,05 P1 : 8,00 0,1 D1(min) : 1,50 Ao : 5,30 0,1 Bo : 5,30 0,1 Ct : 9,5 0,1 P1 Date Code t Do Po P2 E G Ct Bo F Ko Typ PIN Marker D1 Ao W2 Reel (all dimensions in mm) A : 330 W1 : 12,4 +2/-0 W2(max) : 18,4 N(min) : 50 C : 13,0 +0,5/-0,2 C A N W1 The minimum bending radius is 45 mm. Tele Filter GmbH Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. G W Filename: tfs 398h.doc Version 1.3 14.02.2007 VI TELEFILTER Air reflow temperature conditions Filter specification TFS 398H 4/5 Conditions Average ramp-up rate (30C to 217C) > 100C > 150C > 217C Peak temperature Time within 5C of actual peak temperature Cool-down rate (Peak to 50C) Time from 30C to Peak temperature Exposure less than 3C/second between 300 and 600 seconds between 240 and 500 seconds between 30 and 150 seconds max. 260C between 10 and 30 seconds less than 6C/second no greater than 300 seconds Chip-mount air reflow profile Temperature / C max. 260C 217C max. 300 s 10 ... 30 s 30 ... 150 s Time / s Tele Filter GmbH Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 398h.doc Version 1.3 14.02.2007 VI TELEFILTER History Version 1.0 1.1 1.2 1.3 Reason of Changes Filter specification TFS 398H 5/5 Name Strehl Strehl Pfeiffer Pfeiffer Date 17.10.2006 26.10.2006 07.02.2007 14.02.2007 Generation of development specification Change insertion loss add of terminating impedances, typical values, filter characteristics and matching configuration new ceiling values of group delay ripple Tele Filter GmbH Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. |
Price & Availability of TFS398H |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |