![]() |
|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
AC-DC DIN Rail 50-200 Watts DRF Series * THE XPERTS IN POWER Input 187-528 VAC 1O * Adjustable Output * High Peak Current Capability * Overvoltage Protection * Overcurrent Protection * International Safety Approvals Specification Input Input Voltage Input Frequency Input Current Inrush Current Power Factor Leakage Current * * * * * * 187-528 VAC single phase (264-746 DC) 47-63 Hz 1.1 A max @ 240 VAC 25/50 A typical @ 240/480 VAC cold start +25 C 0.98/0.93 typical at 240/480 VAC for DRF200 0.75 mA max (1.5 mA DRF200) General Efficiency Isolation * * 82% typical at 240 VAC 3000 VAC Input to Output 2000 VAC Input to Ground 500 VAC Output to Ground 120 kHz PWM, 50 kHz PFC (DRF200) Switching Frequency * Environmental Operating Temperature Storage Temperature Humidity Shock Vibration * * * * * -10 C to +70 C (+60 C DRF200) Contact Technical Sales for derating -20 C to +75 C 20-90% non condensing 20 G, 11 ms once on the X axis 2 G 10-55 Hz 3 axis Output Output Voltage Output Voltage Adjustment Minimum Load Start Up Time Hold Up Time Drift Line Regulation Load Regulation Ripple & Noise Overvoltage Protection Overcurrent Protection Temperature Coefficient Thermal Protection * * * * * * * * * * 24 VDC nominal 10% No minimum load required 800 ms max with 240 VAC 10 ms (100 ms DRF200) typical at 240 VAC & 100% load 100 mV max 96 mV max 150 mV 0-100% load, 480 mV max 0-peak load 680 mV pk-pk max 20 MHz bandwidth & 100% load 115-150% of nominal rating, recycle input to reset 240 VAC & 100% load >105% of peak current, auto recovery 0.04%/C Recycle input to reset EMC & Safety Emissions ESD Susceptability Radiated Susceptibility EFT/Burst Surge Safety Approvals * * * * * * EN55022 Level A conducted EN55022 Level A radiated EN61000-4-2 Level 2 (Level 4 DRF200) EN61000-4-3 Level 3 EN61000-4-4 Level 4 EN61000-4-5 Level 3 UL1950, cUL, EN60950, EN50178 * * * * * www.xpplc.com sales@xpplc.com OUTPUT VOLTAGE & CURRENT RATINGS Output Voltage 21.6 - 26.4 V 21.6 - 26.4 V 21.6 - 26.4 V Notes 1. Peak current for 150 ms in every 30 second period. Only available with an input voltage of 240 to 528 VAC. DRF Peak(1) 6.7 A 10.0 A 42.0 A Model Number DRF50US24-N1 DRF75US24-N1 DRF200PS24-N1 Output Current Nominal 2.1 A 3.1 A 8.4 A * Mechanical Details DRF50 Model Weight: <630g DRF200 Model Weight: <1700g DRF75 Model Weight:<750g Peak Loading Curves NOTE: ( ) for DRF200 models t 150 ms, 30 s T (t 50 ms, 30 s T DRF200) www.xpplc.com sales@xpplc.com Rev 3.0 |
Price & Availability of DRF50US24-N1
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |