 Unit type
Ordering information
PAA
PAA600F
R
PAA 600
1 2 3
F
4
-5
5
-O
1Series name 2Output wattage 3Universal input 4Output voltage 5Optional C :with Coating G :Low leakage current R :Positive logic control W :with Alarm signal
Recommended Noise Filter NAC-16-472
High voltage pulse noise type : NAP series Low leakage current type : NAM series
*The Noise Filter is recommended *to connect with several devices.
MODEL MAX OUTPUT WATTAGE[W] DC OUTPUT
PAA600F-3 360 3V 120A
PAA600F-5 600 5V 120A
PAA600F-12 636 12V 53A
PAA600F-15 645 15V 43A
PAA600F-24 648 24V 27A
PAA600F-48 624 48V 13A
SPECIFICATIONS
MODEL VOLTAGE[V] CURRENT[A] FREQUENCY[Hz] EFFICIENCY[%] ACIN 100V POWER FACTOR ACIN 200V ACIN 100V INRUSH CURRENT[A] ACIN 200V LEAKAGE CURRENT[mA] VOLTAGE[V] CURRENT[A] LINE REGULATION[mV] LOAD REGULATION[mV] 0 to +50C *1 RIPPLE[mVp-p] -10 - 0C *1 0 to +50C *1 RIPPLE NOISE[mVp-p] -10 - 0C *1 0 to +50C TEMPERATURE REGULATION[mV] -10 to +50C *2 DRIFT[mV] START-UP TIME[ms] HOLD-UP TIME[ms] OUTPUT VOLTAGE ADJUSTMENT RANGE[V] OVERCURRENT PROTECTION OVERVOLTAGE PROTECTION OPERATING INDICATION REMOTE SENSING REMOTE ON/OFF INPUT-OUTPUT -RC INPUT-FG OUTPUT-RC-FG OUTPUT-RC OPERATING TEMP.,HUMID.AND ALTITUDE STORAGE TEMP.,HUMID.AND ALTITUDE VIBRATION IMPACT AGENCY APPROVALS CONDUCTED NOISE HARMONIC ATTENUATOR CASE SIZE/WEIGHT COOLING METHOD ACIN 100V ACIN 200V PAA600F-3 PAA600F-5 PAA600F-12 PAA600F-15 PAA600F-24 AC85 - 264 1f or DC120 - 340 5.4typ 8.2typ 2.7typ 4.1typ 50/60 (47 - 63) 70typ 76typ 80typ 81typ 83typ 0.99typ (Io=100%) 0.95typ (Io=100%) 20typ (Io=100%) 40typ (Io=100%) 0.75max (60Hz, According to UL, CSA, VDE and DEN-AN) 3 5 12 15 24 120 120 53 43 27 20max 20max 48max 60max 96max 40max 40max 100max 120max 150max 80max 80max 120max 120max 120max 140max 140max 160max 160max 160max 120max 120max 150max 150max 150max 160max 160max 180max 180max 180max 40max 50max 120max 150max 240max 50max 60max 150max 180max 290max 12max 20max 48max 60max 96max 500max (ACIN 85V, Io=100%) 20typ (ACIN 100V, Io=100%) 2.85 - 3.45 t10% Works over 105% of rating and recovers automatically 4.00 - 5.25V Works at 115 - 140% of rating LED (Green) Provided Provided AC3,000V 1minute, Cutoff current = 10mA max,DC500V 50MW min (At Room Temperature) AC2,000V 1minute, Cutoff current = 10mA max,DC500V 50MW min (At Room Temperature) AC500V 1minute, Cutoff current = 100mA max,DC500V 50MW min (At Room Temperature) AC100V 1minute, Cutoff current = 100mA max,DC100V 50MW min (At Room Temperature) -10 to +65C, 20 - 90%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000feet) -20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axis 196.1m/s2 (20G), 11ms, once each X, Y and Z axis UL60950-1, EN60950-1, EN50178, CSA C22.2 No.234 Complies with DEN-AN and IEC60950-1 Complies with FCC-B, CISPR22-B, EN55022-B, VCCI-B Complies with IEC61000-3-2 190X92X200mm (without terminal block and screw) (WXHXD) /4.0kg max Forced cooling (internal fan) PAA600F-48
INPUT
83typ
OUTPUT
48 13 192max 300max 150max 200max 200max 300max 480max 580max 192max
PROTECTION CIRCUIT AND OTHERS
ISOLATION
max
ENVIRONMENT
SAFETY AND NOISE REGULATIONS OTHERS
*1 According to 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN : RM101). *2 Drift is change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output. * Avoid prolonged use under over-load.
A-58
Distribution: RSG Electronic Components GmbH Sprendlinger Landstr. 115 D-63069 Offenbach/Germany Tel. +49 69 984047-0 Fax +49 69 984047-77 info@rsg-electronic.de www.rsg-electronic.de

Anderungen vorbehalten / subject to change without notice
PAA600F
External view
4-M4(Top) M4
Name plate Short piece
PAA
200 10 6.6 5 + 100-0.5 55 45 28max 19.5 + 150-0.5 + 160-0.5
(Top)
125
118
8.6
10
FG hole M4
Output (-) terminal
V.ADJ
AC (L) AC (N) FG RG RC CB VB -S -M +M +S
15.5
Output (+) terminal
9
9
Output voltage adjust
12
79.5
M5 LED Terminal cover
15 20
+ 100-0.5 75.5 47.5
4-M4
8-M4(Bottom)
+ 60-0.5 16
(Both sides)
92
+ 170-0.5 190
AIR FLOW Weight: 4.0kg or less Tolerance +1 -
+ 160-0.5
(Bottom)
20
7max
Performance data
RISE TIME & FALL TIME
(PAA600F-5 )
EFFICIENCY (PAA600F-5)
82 80
78
EFFICIENCY
76
DC Output AC Input ACIN 100V Io=100%
74
10
Mounting torque:1.5N . m(16kgf . cm)max
72
Load factor 100% Load factor 50%
70
50ms/DIV
0
100
140
180
220
260
300
INPUT VOLTAGE
V
HARMOINC CURRENT (PAA600F-5)
10
HARMONIC CURRENT (PAA600F-5)
10
Harmonic current standard class A,D(at odd number)
HARMONIC CURRENT
HARMONIC CURRENT
1
Load factor 100% Input voltage AC 100V
A
A
Harmonic current standard class A,D(at odd number)
1
Load factor 100% Input voltage AC 230V
0.1
0.1
0.01
0.01
0.001 0
10
20
30
40
0.001 0
10
20
30
40
HARMONIC ORDER
HARMONIC ORDER
Distribution: RSG Electronic Components GmbH Sprendlinger Landstr. 115 D-63069 Offenbach/Germany Tel. +49 69 984047-0 Fax +49 69 984047-77 info@rsg-electronic.de www.rsg-electronic.de

A-59
Anderungen vorbehalten / subject to change without notice