|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
IHB100TC 100 Watt Triple Output Half Brick DC/DC Converter OBSOLETE PRODUCT Contact factory for replacement model RoHS Compliant 33 - 75V Input Range Each Channel Independently Current Limited High Efficiency: 88% Typical 1500VDC Isolation Between Input and Output Operation to 100 C Baseplate Temperature 50 S Transient Recovery, 0-90% Load Step Primary & Secondary Remote On/Off IHB100TC Series Approved to UL/CUL 1950, EN60950 ISO9001 CERTIFIED The IHB100TC series triple output standard half brick modules are designed for today's demanding industrial applications. Available in two wide range inputs, these isolated converters offer many features in the standard models. With a complement of safety agency approvals and low noise operations, the converters respond extremely fast to change in load conditions. Inherent in the design are very well-controlled output voltage and minimal need for minimum loading on main (V1) output. PRODUCT SELECTION CHART MODEL IHB100T480312C IHB100T480315C IHB100T480512C IHB100T480515C INPUT VOLTAGE (VDC) 48 (33-75) 48 (33-75) 48 (33-75) 48 (33-75) V1 () 3.3 3.3 5.1 5.0 RATED VOUT (VDC) V2 () V3 () 12 15 12 15 12 15 12 15 V1() 30 30 20 20 RATED MAXIMUM IOUT (A) V2() V3() 4.2 3.4 4.2 3.4 4.2 3.4 4.2 3.4 ABSOLUTE MAXIMUM RATINGS Output Short-Circuit Duration Continuous Baseplate Temperature Storage Temperature Input to Output Isolation +100C +125C 1500 VDC EFFICIENCY vs TEMPERATURE TCASE = +40C, nominal input voltage, nominal load, recommended external components applied, unless otherwise specified.* Change in Efficiency (%) Case Temperature (C) SPECIFICATIONS, ALL MODELS Specifications are at TCASE = +40C nominal input voltage unless otherwise specified. PARAMETER CONDITIONS Peak - Peak DC to 1KHz Output Power = 100W VIN = 30V POUT = 0, VIN, Min 33 50 TYP 48 60 MAX 75 370 UNITS VDC mA dB A W mC mA mA INPUT Voltage Range Reflected Ripple Current Input Ripple Rejection Maximum Input Current No Load Power Dissipation Inrush Charge Quiescent Operating Current Primary On/Off Disabled Secondary On/Off Disabled 5 6 0.247 7.5 15 10 20 PARAMETER ISOLATION Input to Each Output Input to Baseplate Channel to Channel Resistance, Input - Output Capacitance, Input - Output Leakage Current GENERAL Set Point Accuracy Turn-on Time Remote On/Off Control Inputs Primary Sink Current-Logic Low Vlow Vhigh Secondary Sink Current-Logic Low Vlow Vhigh External Synchronization Input Frequency Pulse Width Source Impedence Input High Voltage Input Low Voltage Input Impedance Switching Frequency Weight TEMPERATURE Operation/Specification Storage Shutdown Thermal Inpedance CONDITIONS Peak Test Any Channel to Any Channel MIN 1500 1500 500 10 TYP MAX UNITS VDC VDC VDC M pF A, rms VISO = 240VAC, 60Hz VIN = Nominal, 50% Load Within 1% of Nominal VOUT Open Collector/Drain VIN = VMAX 2000 180 1 5 3.5 % mSec GENERAL 7 0.8 Open Collector 100 0.4 Open Collector 440 150 4 0 470 470 480 520 320 47 5 1 490 3 (85) +100 +125 +115 8.2 mA V Open Collector/Drain A V KHz nSec V V KHz oz (g) C C C C/W Case Temperature -40 -55 +100 Case to Ambient PARAMETER Output Power CONDITIONS Total Combined O/P Power = 100 Watts Max IO Nom V1 Min Nom 50 3.3 15 100 .02 Max 100 30.0 200 3.80 .05 0 Min Nom 25 12.2 2.1 150 .02 Max 50 V2 Min Nom 25 12.2 2.1 150 .02 1.0 Max 50 4.2 500 .05 2.0 W V A mV V %/C % % A A mV Sec V % V3 IHB100T480312C OUTPUT Set Point Voltage Output Current, IOUT Output Ripple, p-p Output Adjust Range Output Temperature Drift Line Regulation Load Regulation Current Limit Inception Short-Circuit Current Transient Response Peak Deviation Settling Time Overvoltage Limit Efficiency 0.5 DC to 20MHz* * VIN, MinVINVIN, Max IO = IO, Nom Min Load to Rated Load Other Outputs Min Load 50 to 100% Load Step VOUT, 1% of VOUT, Nom IOUT1=15A, (IOUT2+IOUT3)= 4.2A F.L. VIN=Nominal 3.15 4.2 0 500 Dependent on V1 .05 0.05 0.50 38 30 150 35 4.2 85 86 0.10 1.0 2.0 1.00 See Regulation Curves 6.0 5.0 See Regulation Curves 6.0 5.0 38 250 50 5.0 6.0 6.0 * See Application Notes available on the web at www.murata-ps.com IHB100TC REV A (RoHS) 05/2006 2 SPECIFICATIONS, ALL MODELS Specifications are at TCASE = +40C nominal input voltage unless otherwise specified. PARAMETER CONDITIONS Total Combined O/P Power = 100 Watts Maximum IO Nom 0.5 DC to 20MHz* * VIN, MinVINVIN, Max IO = IO, Nom Min Load to Rated Load Other Outputs Min Load 50 to 100% Load Step VOUT, 1% of VOUT, Nom IOUT1=15A, (IOUT2+IOUT3) = 3.4A F.L. VIN=Nominal 4.2 85 150 35 86 250 50 5.0 mV Sec V % 3.15 .02 0.05 0.50 38 30 V1 Min Nom 50 3.3 15 100 Max 100 30.0 200 3.80 .05 0.10 1.0 38 0 Min Nom 25 15.85 1.66 125 .02 Max 50 V2 Min Nom 25 15.85 1.66 125 .02 Max 50 3.33 500 .05 W V A mV V %/C % % A A V3 U IHB100T480315C OUTPUT Output Power Set Point Voltage Output Current, IOUT Output Ripple, p-p Output Adjust Range Output Temperature Drift Line Regulation Load Regulation Current Limit Inception Short-Circuit Current Transient Response Peak Deviation Settling Time Overvoltage Limit Efficiency 3.33 0 500 Dependent on V1 .05 1.0 2.0 See Regulation Curves 5.0 4.0 5.0 1.0 2.0 See Regulation Curves 5.0 4.0 5.0 PARAMETER Output Power CONDITIONS Total Combined O/P Power = 100 Watts Combined IO Nom V1 Min Nom 50 0.5 5.1 10 100 .02 Max 100 20 150 5.50 .05 0.10 1.0 26.0 300 50 7.0 0 Min Nom 25 12 2.1 150 .02 1.0 Max 50 V2 Min Nom 25 12 2.1 150 .02 1.0 Max 50 4.2 500 .05 2.0 W V A mV V %/C % % A A mV Sec V % V3 U IHB100T480512C OUTPUT Set Point Voltage Output Current, IOUT Output Ripple, p-p Output Adjust Range Output Temperature Drift Line Regulation Load Regulation Current Limit Inception Short-Circuit Current Transient Response Peak Deviation Settling Time Overvoltage Limit Efficiency DC to 20MHz* * VIN, MinVINVIN, Max IO = IO, Nom Min Load to Rated Load Other Outputs Min Load 50 to 100% Load Step 4.75 4.2 0 500 Dependent on V1 .05 2.0 0.05 0.50 26.0 20.0 200 See Regulation Curves 6.0 5.0 6.0 See Regulation Curves 6.0 5.0 6.0 VOUT, 1% of VOUT, Nom IOUT1=10A, (IOUT2+IOUT3) = 4.2A F.L. VIN=Nominal 6.0 86 35 87 PARAMETER Output Power CONDITIONS Total Combined O/P Power = 100 Watts Max IO Nom V1 Min Nom 50 5.0 0.5 10 100 .02 Max 100 20 150 5.50 .05 1.0 1.0 26.0 300 50 7.0 0 Min Nom 25 15.3 1.66 125 .02 Max 50 V2 Min Nom 25 15.3 Max 50 3.33 500 .05 W V A mV V %/C % % A A mV Sec V % V3 U IHB100T480515C OUTPUT Set Point Voltage Output Current, IOUT Output Ripple, p-p Output Adjust Range Output Temperature Drift Line Regulation Load Regulation Current Limit Inception Short-Circuit Current Transient Response Peak Deviation Settling Time Overvoltage Limit Efficiency DC to 20MHz* * VIN, MinVINVIN, Max IO = IO, Nom Min Load to Rated Load Other Outputs Min Load 50 to 100% Load Step 4.60 3.33 0 1.66 500 125 Dependent on V1 .05 .02 0.05 0.05 26.0 20.0 200 1.0 2.0 See Regulation Curves 5.0 4.0 5.0 1.0 2.0 See Regulation Curves 5.0 4.0 5.0 VOUT, 1% of VOUT, Nom IOUT1=10A, (IOUT2+IOUT3) = 4.2A F.L. VIN=Nominal 6.0 86 35 87 * See Application Notes available on the web at www.murata-ps.com IHB100TC REV A (RoHS) 05/2006 3 MECHANICAL SIDE VIEW PIN SIDE DOWN PIN CONNECTIONS 1 2 3 4 5 6 7 8 9 10 11 12 PRIMARY ON/OFF -VIN +VIN SYNC IN -V2 +V2 TRIM +V1 -V1 SECONDARY ON/OFF +V3 -V3 PIN SIDE UP NOTES: All dimensions are in inches (millimeters). PIN PLACEMENT TOLERANCE: 0.005" MECHANICAL TOLERANCE: 0.015" Marked with: specific model ordered, date code, job code. MATERIAL: Units are encapsulated in a low thermal resistance molding compound which has excellent chemical resistance and electrical properties in high humidity environments and over a wide operating temperature range. The encapsulant and outer shell of the unit have UL94V-0 ratings. Lead material is solder plated to allow ease of solderability. THROUGH-HOLE SOLDERING INFORMATION These devices are intended for wave soldering or manual soldering. They are not intended to be subject to surface mount processes under any circumstances. The normal wave soldering process can be used with these devices where the device is subjected to a maximum wave temperature of 260C for a period of no more than 10 seconds. Within this time and temperature range, the integrity of the device's plastic body will not be compromised and internal temperatures within the converter will not exceed 175C. Care should be taken to control manual soldering limits identical to that of wave soldering. USA: Canada: UK: Mansfield (MA), Tel: (508) 339 3000, email: sales@murata-ps.com Toronto, Tel: (866) 740 1232, email: toronto@murata-ps.com Milton Keynes, Tel: +44 (0)1908 615232, email: mk@murata-ps.com Montigny Le Bretonneux, Tel: +33 (0)1 34 60 01 01, email: france@murata-ps.com Tokyo, Tel: 3-3779-1031, email: sales_tokyo@murata-ps.com Osaka, Tel: 6-6354-2025, email: sales_osaka@murata-ps.com Shanghai, Tel: +86 215 027 3678, email: shanghai@murata-ps.com Guangzhou, Tel: +86 208 221 8066, email: guangzhou@murata-ps.com Murata Power Solutions, Inc. 11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A. Tel: (508) 339-3000 (800) 233-2765 Fax: (508) 339-6356 www.murata-ps.com email: sales@murata-ps.com ISO 9001 & ISO 14001 REGISTERED Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without notice. (c) 2009 Murata Power Solutions, Inc. France: Japan: China: Germany: Munchen, Tel: +49 (0)89-544334-0, email: ped.munich@murata-ps.com Singapore: Parkway Centre, Tel: +65 6348 9096, email: singapore@murata-ps.com IHB100TC REV A (RoHS) 05/2006 4 |
Price & Availability of IHB100T480312C |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |