53RV Series * Three-phase Motor Reversing solid-state relay; * Ratings from 25A and 50A per phase @ 48-530 VAC * SCR output for heavy industrial loads * DC control * LED input status indicator PRODUCT SELECTION Control Voltage 4-32 VDC 25A D53RV25C 50A D53RV50C AVAILABLE OPTIONS OUTPUT SPECIFICATIONS (1) Description Operating Voltage (47-63Hz) [Vrms] Maximum Load Current (3) [Arms] Transient Overvoltage [Vpk] Maximum Off-State Leakage Current @ Rated Voltage [mArms] Minimum Load Current [Arms] Maximum Surge Current 50/60 Hz (16.6ms) [Apk] 1 Second Surge Current 50/60 Hz [Apk] Maximum On-State Voltage Drop @ Rated Current [Vpk] Maximum IT for Fusing (50/60 Hz, 1/2 cycle) [A sec] Thermal Resistance Junction to Case (Rjc) [C/W] Minimum Off-State dv/dt @ Maximum Rated Voltage [V/sec] (2) HP Ratings at 120V HP Ratings at 240V HP Ratings at 480V D53RV25C 48-530 25 1100 3 0.1 475/500 100 1.35 1130/1030 0.26 500 0.75 1 3 D53RV50C 48-530 50 1100 3 0.1 710/750 150 1.35 2520/2320 0.25 500 1.5 3 7.5 INPUT SPECIFICATIONS (1) Description Control Voltage Range Minimum Turn-On Voltage Minimum Turn-Off Voltage Minimum Input Current (for on-state) Maximum Input Current Input Resistance Maximum Turn-On Time [msec] Maximum Turn-Off Time [msec] Interlocking Time [msec] Parameters 4-32 VDC 4.0 VDC 1.0 VDC 17mA 25mA Current Regulated 150 1/2 Cycle 100 GENERAL SPECIFICATIONS Description Input to Output Isolation Input/ Output to Ground Isolation Maximum Capacitance, Input/Output Ambient Operating Temperature Range Ambient Storage Temperature Range Weight (typical) Housing Material Terminals Input Terminal Screw Torque Range:[in lbs/Nm] Output Terminal Screw Torque Range:[in lbs/Nm] Parameters 4000 Vrms 2500 Vrms 8 pF -40 to 80C -40 to 100 C 13.1 oz (370g) UL 94V0 (self extinguishing Screws and Clamps Furnished 16.8/1.9 21.2/2.4 GENERAL NOTES GENERAL NOTES 1) All parameters at 25C unless otherwise specified. 2) Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1 THERMAL DERATE INFORMATION MECHANICAL SPECIFICATIONS AGENCY APPROVALS Rev. 012010 ANNEX - ENVIROMENTAL INFORMATION |
Price & Availability of D53RV25C
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |