![]() |
|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
ELECTRONIC COMPONENTS RSG RSG Electronic Components GmbH Sprendlinger Landstr. 115 D-63069 Offenbach/Germany Tel. +49 69 984047-0 Fax +49 69 984047-77 info@rsg-electronic.de www.rsg-electronic.de Anderungen vorbehalten / subject to change without notice 1000W Single Output Power Supply Features : RSP-1000 series Universal AC input / Full range AC input active surge current limiting Built-in 5V/0.5A auxiliary power Built-in active PFC function, PF>0.95 Protections:Short circuit/Over load/Over voltage/Over temperature Output voltage can be trimmed between 40 ~ 110% of the rated output voltage Forced air cooling by built-in DC fan 3 High power density 10.7w/inch 1U low profile 41mm Active current sharing up to 4000W(3+1) (Note.8) DC OK Signal Built-in remote ON-OFF control Built-in remote sense function 3 years warranty SPECIFICATION MODEL DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER OUTPUT RSP-1000-12 12V 60A 0 ~ 60A 720W RSP-1000-15 15V 50A 0 ~ 50A 750W 150mVp-p 13.5 ~ 16.5V 1.0% 0.5% 0.5% 16ms/115VAC at full load 127 ~ 370VDC 0.98/115VAC at full load 85% 6A/230VAC 40A/230VAC 88% 88% RSP-1000-24 24V 40A 0 ~ 40A 960W 150mVp-p 20 ~ 26.4V 1.0% 0.5% 0.5% RSP-1000-27 27V 37A 0 ~ 37A 999W 150mVp-p 24 ~ 30V 1.0% 0.5% 0.5% .. RSP-1000-48 48V 21A 0 ~ 21A 1008W 150mVp-p 43 ~ 55V 1.0% 0.5% 0.5% RIPPLE & NOISE (max.) Note.2 150mVp-p VOLTAGE ADJ. RANGE 10 ~ 13.5V VOLTAGE TOLERANCE Note.3 LINE REGULATION LOAD REGULATION SETUP, RISE TIME HOLD TIME (Typ.) VOLTAGE RANGE FREQUENCY RANGE POWER FACTOR (Typ.) 1.0% 0.5% 0.5% 300ms, 50ms at full load 16ms/230VAC Note.5 90 ~ 264VAC 47 ~ 63Hz 0.95/230VAC 83% 12A/115VAC 25A/115VAC <2.0mA / 240VAC 105 ~ 125% rated output power Protection type : Constant current limiting, recovers automatically after fault condition is removed 13.8 ~ 16.8V 17 ~ 20.5V 27.6 ~ 32.4V 31 ~ 36.5V 56.6 ~ 66.2V Protection type : Shut down o/p voltage, re-power on to recover 5 (TSW1 ) Detect on heatsink of power transistor 85 5 (TSW2 ) Detect on heatsink of O/P diode; 75 Protection type : Shut down o/p voltage, recovers automatically after temperature goes down 5V @ 0.5A (+5%, -8%) 90% INPUT EFFICIENCY (Typ.) AC CURRENT (Typ.) INRUSH CURRENT (Typ.) LEAKAGE CURRENT OVER LOAD PROTECTION OVER VOLTAGE OVER TEMPERATURE AUXILIARY POWER(AUX) Power off : open between on/off(pin6) & -S(pin2) on CN50 REMOTE ON/OFF CONTROL Note.6 Power on : short between on/off(pin6) & -S(pin2) on CN50 Open collector signal low when PSU turns on, Max. sink current :10mA FUNCTION DC OK SIGNAL OUTPUT VOLTAGE TRIM Note.6 Adjustment of output voltage is possible between 40 ~ 110% of rated output CURRENT SHARING(CS)Note.7 Please refer to function manual -20 ~ +60 (Refer to output load derating curve) WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE 20 ~ 90% RH non-condensing -40 ~ +85 , 10 ~ 95% RH 0.02%/ (0 ~ 50 ) 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes UL60950-1, TUV EN60950-1 Approved I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC SAFETY & ISOLATION RESISTANCE EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) EMC (Note 4) HARMONIC CURRENT Compliance to EN61000-3-2,-3 EMS IMMUNITY MTBF OTHERS NOTE Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, EN61000-6-2, EN61204-3 Heavy industry level, criteria A 35K hrs min. MIL-HDBK-217F (25 295*127*41mm (L*W*H) 1.95Kg; 6pcs/12.7Kg/0.99CUFT ) DIMENSION PACKING 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 5. Derating may be needed under low input voltages. Please check the derating curve for more details. 6. The power supply unit will have no output if the shorting connector is not assembled. It contains two shorting wires: one is from on/off(pin6) to -s(pin2) and the other is from Vco(pin8) to Vca(pin10). Please refter to function manual for details. 7. In parallel connection, maybe only one unit operate if the total output load is less than 5% of rated load condition. 8. Please consult MEAN WELL for applications of more units connecting in parallel. 1000W Single Output Power Supply Mechanical Specification 277.7 RSP-1000 Case No. 952B 7.8 series Unit:mm 6 20.5 3-M4 L=6 295 41 21 18.5 34.5 -V 127 21 59 +V 25.4 CN50 12 11 3 2 1 TB1 10 7 90 SVR51 Air flow direction 3-M4 L=4 20.5 3-M4 L=6 6 277.7 AC Input Terminal Pin. No. Assignment Pin No. 1 2 3 Assignment AC/N AC/L FG Control pin number assignment (CN50) : JST B12B-PHDSS or equivalent Pin No. 1 2 3 4 Assignment +S -S G-AUX 5V-AUX Pin No. 5 6 7 8 Assignment DC-OK ON/OFF CS Vco Pin No. 9 10 11,12 Assignment Vci Vca GND Mating Housing JST PHDR-12VS or equivalent Terminal JST SPHD-002T-P0.5 or equivalent 7.8 25.4 Block Diagram +S I/P EMI FILTER ACTIVE INRUSH CURRENT LIMITING PFC fosc : 110KHz PWM fosc : 90KHz RECTIFIERS & PFC PFC CONTROL O.T.P. POWER SWITCHING RECTIFIERS & FILTER O.V.P. DETECTION CIRCUIT REMOTE CONTROL FAN RECTIFIERS & FILTER +V -V -S O.L.P. PWM CONTROL LOAD SHARING DC-OK ON/OFF CS AUX POWER (5V/0.5A) AUX POWER Derating Curve 100 Static Characteristics 100 90 Ta=25 80 80 70 60 LOAD (%) LOAD (%) 60 50 40 40 20 -20 0 10 20 30 40 50 60 70 (HORIZONTAL) 90 95 100 115 264 AMBIENT TEMPERATURE ( ) INPUT VOLTAGE (VAC) 60Hz File Name:RSP-1000-SPEC 2006-11-21 ELECTRONIC COMPONENTS RSG RSG Electronic Components GmbH Sprendlinger Landstr. 115 D-63069 Offenbach/Germany Tel. +49 69 984047-0 Fax +49 69 984047-77 info@rsg-electronic.de www.rsg-electronic.de Anderungen vorbehalten / subject to change without notice 1000W Single Output Power Supply Function Description of CN50 RSP-1000 series Pin No. Function Description Positive sensing. The +S signal should be connected to the positive terminal of the load. The +S and -S leads should be twisted in pair to 1 +S minimize noise pick-up effect. The maximum line drop compensation is 0.5V. 2 3 4 5 6 7 8 9 10 11,12 -S Negative sensing. The -S signal should be connected to the negative terminal of the load. The -S and +S leads should be twisted in pair to minimize noise pick-up effect. The maximum line drop compensation is 0.5V. G-AUX Auxiliary voltage output ground. The signal return is isolated from the output terminals (+V & -V). Auxiliary voltage output, 4.6~5.25V, referenced to pin 3(G-AUX). The maximum load current is 0.5A. This output has the built-in oring 5V-AUX diodes and is not controlled by the "remote ON/OFF control". Open collector signal, referenced to pin11,12(GND). Low when PSU turns on. The maximum sink current is 10mA and the maximum DC_OK external voltage is 5.6V. ON/OFF Turns the output on and off by electrical or dry contact between pin 6 ( ON/OFF) and pin 2 (-S). Short: Power ON, Open: Power OFF. Current sharing signal. When units are connected in parallel, the CS pins of the units should be connected to allow current balance CS between units. Vco Vci Vca GND Short connecting between Vco (pin8) and Vca (pin10) if output voltage trim function is not used. Connect to external DC voltage source for output voltage triming, referenced to pin 2 (-S). Output voltage can be trimmed between 40 ~ 110% of the rated output voltage. Connect to external resistor (1/8W) for output voltage triming. Output voltage can be trimmed between 40 ~ 110% of the rated output voltage. Please refer to function manual for details. These pins connect to the negative terminal (-V). Return for DC_OK Signal output. Function Manual 1."Remote ON/OFF" and "Output voltage trim" functions are not used. The power supply unit will have no output if the shorting connector (accessory comes along with the PSU) is not assembled. It contains two shorting wires : one is from ON/OFF (pin6) to -S (pin2) and the other is from Vco (pin8) to Vca (pin10). +V 1 11 2 12 -V SVR51 CN50 TB1 1 CN50 AUXG DC_OK CS Vci Vca 11 GND GND 12 LOAD + - +S -S AUX ON/OFF Vco Fig 1.1 2 (Shorting connector) File Name:RSP-1000-SPEC 2006-11-21 ELECTRONIC COMPONENTS RSG RSG Electronic Components GmbH Sprendlinger Landstr. 115 D-63069 Offenbach/Germany Tel. +49 69 984047-0 Fax +49 69 984047-77 info@rsg-electronic.de www.rsg-electronic.de Anderungen vorbehalten / subject to change without notice 1000W Single Output Power Supply RSP-1000 series 2.Remote ON/OFF The PSU can be turned ON/OFF by using the "Remote ON/OFF" function Between ON/OFF(pin6) and -S(pin2) SW ON (Short) SW OFF (Open) Output Status ON OFF +V 1 11 2 12 -V SVR51 CN50 TB1 1 CN50 AUXG DC_OK CS Vci Vca 11 GND GND 12 LOAD + Fig 2.1 +S -S 2 AUX ON/OFF Vco SW 3.DC_OK signal "DC_OK" is an open collector signal. It indicates the output status of the PSU. It can operate in two ways : One is sinking current from external TTL signal ; the other is sending out a TTL voltage signal. 3-1 Sink current : The maximum sink current is 10mA and the maximum external voltage is 5.6V. 3-2 TTL voltage signal : Between DC- OK(pin5) and GND(pin11&12) 0 ~ 1V 3.3 ~ 5.6V Output Status ON OFF CN50 AUXG DC_OK CS Vci Vca +V 1 11 2 12 -V SVR51 CN50 TB1 Fig 3.1 1 +S -S 2 11 GND GND 12 AUX ON/OFF Vco 4.Remote Sense The remote sensing compensates voltage drop on the load wiring up to 0.5V. +V 1 11 2 12 -V SVR51 CN50 TB1 1 Sense lines should be twisted in pairs +S -S 2 CN50 AUXG DC_OK CS Vci Vca 11 GND GND 12 +S (pin1) LOAD + -S - (pin2) AUX ON/OFF Vco Fig 4.1 File Name:RSP-1000-SPEC 2006-11-21 ELECTRONIC COMPONENTS RSG RSG Electronic Components GmbH Sprendlinger Landstr. 115 D-63069 Offenbach/Germany Tel. +49 69 984047-0 Fax +49 69 984047-77 info@rsg-electronic.de www.rsg-electronic.de Anderungen vorbehalten / subject to change without notice 1000W Single Output Power Supply RSP-1000 series 5.Output Voltage TRIM Output voltage of RSP-1000 can be trimmed between 40% ~ 110% of its rated value by the following methods : (1)Using external voltage source between "Vci"(pin9) and "-S"(pin2) that is shown in Fig5.1 Vout 120 OVP 120%(Typ.) OUTPUT VOLTAGE (%) 100 80 60 40 20 Vci(Referenced to -S) Non-Linear +V 1 11 2 12 -V SVR51 CN50 TB1 1 2 3 4 5 6 1 +S -S 2 CN50 AUXG DC_OK AUX ON/OFF CS Vco Vci Vca 11 GND GND 12 EXTERNAL VOLTAGE (VDC) External Voltage Fig 5.1 (2)Connecting a resistor externally that in shown in Fig 5.2 & Fig 5.3 (A) O/P voltage goes down Vout 100 90 80 Non-Linear 70 60 50 40 390 560 820 1K2 2K2 4K7 open R1, 1/8W(Typ.) OUTPUT VOLTAGE (%) 1 +S -S 2 CN50 AUXG DC_OK AUX ON/OFF CS Vco Vci Vca 11 GND GND 12 R1 Fig 5.2 EXTERNAL RESISTOR ( ) (B)O/P voltage goes up Vout OVP 120%(Typ.) OUTPUT VOLTAGE (%) 110 Non-Linear 105 1 +S -S 2 CN50 AUXG DC_OK AUX ON/OFF CS Vco Vci Vca 11 GND GND 12 100 R2 open 18K 7K5 R2, 1/8W(Typ.) Fig 5.3 EXTERNAL RESISTOR ( ) File Name:RSP-1000-SPEC 2006-11-21 ELECTRONIC COMPONENTS RSG RSG Electronic Components GmbH Sprendlinger Landstr. 115 D-63069 Offenbach/Germany Tel. +49 69 984047-0 Fax +49 69 984047-77 info@rsg-electronic.de www.rsg-electronic.de Anderungen vorbehalten / subject to change without notice 1000W Single Output Power Supply RSP-1000 series 6.Current Sharing with Remote Sensing RSP-1000 has the built-in active current sharing function and can be connected in parallel to provide higher output power : (1)Parallel operation is available by connecting the units shown as below. (+S,-S and CS are connected mutually in parallel). (2)Difference of output voltages among parallel units should be less than 2%. (3)The total output current must not exceed the value determined by the following equation. (output current at parallel operation)=(Rated current per unit) (Number of unit) 0.9 (4)In parallel operation 4 units is the maximum, please consult the manufacturer for applications of more connecting in parallel. (5)The power supplies should be paralleled using short and large diameter wiring and then connected to the load. PSU 1 11 2 12 -V SVR51 CN50 PSU 1 11 2 12 -V SVR51 CN50 PSU 1 11 2 12 -V SVR51 CN50 PSU 1 11 2 12 -V SVR51 CN50 +V TB1 +V TB1 +V TB1 +V TB1 +S(pin1) -S(pin2) CS(pin7) +V LOAD -V Sense lines should be twisted in pairs Fig 6.1 1 +S -S 2 CN50 AUXG DC_OK AUX ON/OFF CS Vco Vci Vca 11 GND GND 12 Note : In parallel connection, maybe only one unit (master) operate if the total output load is less than 5% of rated load condition. The other PSUs (slaves) may go into standby mode and their output LEDs will not turn on. File Name:RSP-1000-SPEC 2006-11-21 ELECTRONIC COMPONENTS RSG RSG Electronic Components GmbH Sprendlinger Landstr. 115 D-63069 Offenbach/Germany Tel. +49 69 984047-0 Fax +49 69 984047-77 info@rsg-electronic.de www.rsg-electronic.de Anderungen vorbehalten / subject to change without notice |
Price & Availability of RSP-1000-48
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |