![]() |
|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
R/MER/F81A.500/A/11/10/2000 RELAIS REED A CONTACT MERCURE/ REED RELAY / MERCURY CONTACT Pour circuit imprime/ page 1 / 2 F/GB For printed circuit board Un contact normalement ouvert mercure/ F81A . 500 One normally open mercury contact sous capot metal/ In metal cover Fonctionnement vertical / vertical operating position 30 caracteristisques principales/ main characteristics tension maximale de commutation/ maximum switching voltage courant maximal de commutation / maximum switching current puissance maximale/ contact rating 500 VDC ou crete (or peak) 1A REF. Marquage/Marking F81A2500 F81A2500 F81A5500 F81A5500 F81A7500 F81A7500 courant traversant/ nominal current 3 A 50 VA materiau de contact/ contact material Mercure 30 9,5 10 HAUT/ UP dimensions en mm / dimensions in mm 3,3 bornage : vue de dessus pas de 2,54 mm wiring : top view step 2,54 mm F81A 25,4 5,08 == caracteristiques de controle/control data REF. tension max/ maximum voltage (V) tension nominale/ nominal voltage (V) tension d'action/ operate voltage to secure the function from -40 to + 85 C (V) tension de relachement/ release voltage (V) consommation nominale a 20 C/power dissipated on the coil at 20 C (mW) 0,2 O0,6 2,54 2 500 7,5 5 3,5 0,4 180 5 500 18 12 8,4 1 144 7 500 36 24 16,8 2 250 Proud to serve you All technical caracteristics are subject to change without previous notice. Caracteristiques sujettes a modifications sans preavis. r celduc e l a i s R/MER/F81A.500/A/10/10/2000 page 2 / 2 F/GB caracteristiques electriques/electrical data resistance initiale de contact/ Initial contact resistance ( 100 mA/ 12 VAC) 100 m resistance de bobine/coil resistance at 20 C F81A 2 500 5 500 7 500 -variation 10 % each 25 C 140 1000 2300 tension de tenue/ hold-on voltage - entre lames/ accross contacts - entre bobine et contact/ between coil and contacts - entre boitier et contact /between case and contacts - entre boitier et bobine/ between case and coil resistance d'isolement/ insulation resistance - entre lames/ accross contacts - entre bobine et contact/ between coil and contacts - entre boitier et contact /between case and contacts - entre boitier et bobine/ between case and coil 1000 Vac 2000 Vac 1000 Vac 1000 Vac 108 1010 1010 109 Temps de commutation maximum / Max switching time Methode de mesure / Test process ---> Alimentation de bobine /Coil voltage: V nominale / nominal voltage a l'action / max. operate time contact travail / normaly open 3 ms au relachement / max. release time contact repos / normaly closed 3 ms Duree de vie electrique/ Electrical life time Duree de vie mecanique/ mecanical life expectancy voltage current ( mA ) caracteristiqueslife expectancyphysical data physiques/ ( - x 106 op. ) rate of failure ( - x 10-9 defaut / op.) temperature de fontionnement/ operating temperature temperature de stockage/ storage temperature poids/ weight chocs/shocks (11ms) vibrations ( 10 to 500 Hz ) nous consulter/ consult us >1. 109 op 100 VAC 60 830 5V 10 200 5 30 V 200 180 5,6 1,2 - 40 a + 85 C - 40 a + 100 C 4,6 gr. max. 30 g 10 g celduc r e l a i s www.celduc.com Rue Ampere B.P. 4 42290 SORBIERS - FRANCE E-Mail : celduc-relais@celduc.com Fax +33 (0) 4 77 53 85 51 Service Commercial France Tel. : +33 (0) 4 77 53 90 20 Sales Dept.For Europe Tel. : +33 (0) 4 77 53 90 21 Sales Dept. Asia : Tel. +33 (0) 4 77 53 90 19 |
Price & Availability of F81A2500
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |