Part Number Hot Search : 
MCP6L1 BCP6925 A30HEVM NTE1362 LA0224CS 33982B AUIRF CP566
Product Description
Full Text Search
 

To Download 900BT Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 Models 900CT & 900BT
Tunable Active Filter Instrument
Single Channel -
Certified
Description Frequency Devices' Models 900CT & 900BT instruments are single channel; 8-pole low-pass or high-pass, front panel tunable filter instruments. The controls allow the user to select a corner frequency between 0.1 Hz and 49.9 kHz with a resolution of 1:499 for each of the four selectable ranges. The instrument exhibits an input impedance of 1 M shunted by 47pF to a single ended signal source. When configured in the differential mode, the instrument has a common mode rejection ratio (CMRR), which exceeds 60dB; in this mode the instrument presents an input impedance of 2 M's shunted by 47pF to a double-ended single source. Front panel gain control also enables the operator to select a gain factor of 0, 10, or 20dB. Standard operational features include: 1) Adjustable Frequency Control 2) Differential Input Amplifiers 3) Adjustable Gain Control 4) Off-set Adjustment 5) Bypass Control 6) BNC Connectors for Signal I/O The optional battery powered 900BT is particularly well suited to applications requiring isolation from an electrically noisy primary power source. Compact size and manual rotary switch front panel controls make 900 instruments a popular, cost effective, easy-to-use solution for signal conditioning applications in the following areas: Anti-aliasing Filters Biomedical/Biotechnology Applications Data Recording/Playback Data Smoothing EKG/EEG Signal Filtering FDM/PCM Signal Filtering Medical Research Industrial Process Control Seismic Analysis Vibration Analysis
Models 900CT 900BT
Standard AC Powered AC Powered, with battery option
Available Low-Pass Filters: Part# #Poles 900L8B 8 900L8L 8 900L8E 8, 6 zero 900L8EY 8, 6 zero 900L8D80 8, 6 zero 900L8D100 8, 6 zero Available High-Pass Filters: Part# #Poles 900H8B 8 900H8E 8, 6 zero 900H8EY 8, 6 zero
Filter Type Page Butterworth 6 Bessel 6 Elliptic, 1.77 6 Elliptic, 2.00 6 Constant Delay 7 Constant Delay 7
Filter Type Butterworth Elliptic, 1.77 Elliptic, 2.00
Page 8 8 8 2 4&5 9 10
Block Diagram Front & Rear panel descriptions General Specifications: Ordering Information
1
1784 Chessie Lane, Ottawa, IL 61350 * Tel: 800/252-7074, 815/434-7800 * FAX: 815/434-8176 e-mail: sales@freqdev.com * Web Address: http://www.freqdev.com
Models 900CT & 900BT
Model 900 Series Instrument Block Diagram
BLOCK DIAGRAM
GAIN (dB)
Single Channel -
Certified
INPUT 10dB 0dB 20dB A-B
A
+
DIFF AMP OFFSET NULLED BYPASS CORNER FREQUENCY TUNING OFFSET TYPICAL ADJUSTMENT FUNCTION
OUT
A
8-POLE TUNABLE FILTER
OUTPUT AMP
B
TYPICAL FRONT PANEL BNC CONNECTOR
1 0
2
3
CORNER FREQUENCY HZ 5 5 4 4 6 4 3 2 1 0 9 7 8 3 2 1
6 7 0.1 8 9
MULTIPLIER 10 1 100
0 FRONT PANEL
2
1784 Chessie Lane, Ottawa, IL 61350 * Tel: 800/252-7074, 815/434-7800 * FAX: 815/434-8176 e-mail: sales@freqdev.com * Web Address: http://www.freqdev.com
Models 900CT & 900BT
Model 900 Series Initial Setup Procedure
The B, C and D switches combined can select base corner frequency values ranging from 1 to 499 Hz in 1 Hz steps with switch weightings as just described. The accuracy of the corner frequency is improved by selecting the largest possible base frequency and down scaling by the MULTIPLIER. The greatest accuracy is obtained with the largest base 400, and the 0.1X MULTIPLIER switch setting.
Relative accuracy of selected 40 Hz actual corner frequency for different multiplier switch settings.
BASE FREQ Msd C 0 4 0 X MULT Lsd E 0.1X 1X 10X
RELATIVE TUNING ACCURACY
Single Channel -
Initial Setup
Certified
Set the OFFSET control for a zero-volt reading on the scope or DVM. Subsequent changes of CORNER FREQUENCY and GAIN control settings will introduce a small dc output offset, which should be zeroed for critical applications. Leaving all other controls unchanged, set the Input Switch to (A-B) and apply a 5Vdc signal simultaneously to input BNCs (A) and (B). The voltage measured at the OUT BNC should be 5 - 5 = 0 Vdc. This completes preliminary test and adjustment.
Corner Frequency Selection To select a corner frequency, simply set the CORNER FREQUENCY switches and the MULTIPLIER switch for the desired numerical value.
Select desired operating voltage 115 Vac or 230 Vac. See note "Q" on Page 5. Set the POWER ON/OFF Switch to ON. A continuously lit POWER lamp indicates proper internal DC voltages, an essential requirement for battery-powered models. Allow the instrument a three-minute warm-up period to achieve thermal equilibrium. To perform initial adjustment and/or operational testing, set the remaining front panel controls as follows: a) The three base CORNER FREQUENCY switches and the MULTIPLIER to the desired corner frequency... b) The OFFSET control to approximately mid-range... c) The GAIN switch to the desired value... d) The BYPASS switch to OUT... e) The INPUT switch to ground ( ). Connect a dc-coupled oscilloscope, of vertical sensitivity 10mV/CM or better, or a digital voltmeter (DVM) to the instrument front panel BNC connector labeled OUT.
B 4 0 0
D 0 0 4
GREATEST LESS LEAST
The CORNER FREQUENCY switch weightings follow standard decimal positional conventions.
Circuit model illustrating the relationship between a filter's differential input and amplifier and external signal and error sources.
DIFFERENTIAL INPUT AMPLIFIER
0d
The differential input The instrument input utilizes a differential input amplifier to reject prevalent forms of electrical interference, while presenting desirable input characteristics to the signal source requiring filtering. The differential input configuration is ideal for measuring the difference between two values rather than the values themselves. Bridge circuits utilizing strain gages, thermocouples and a variety of other types of transducers generate differential full-scale output voltages in the order of millivolts that are often superimposed upon volt-level reference and noise values. The importance of CMRR In actual system environments, each signal and power return conductor can generate an interference voltage proportional to the net conductor resistance and the electrical current level. Any such interference voltages appear as common mode signals to the amplifier, and are rejected as such.
INPUT SIGNAL AND NOISE VOLTAGE SOURCES R SA
B
10 dB
A
(+)
20 dB
*
GAIN = K
+ DIFF AMP OUT
V A VCM
VB
RCM+ RD SIGNAL COMMON RSB RCM(-)
FILTER/ BYPASS
OUTPUT AMPLIFER
B
-Vs COM
Vo = K(VA - VB) + Vcm/CMRR : WHERE K = 1, 10 AND 10 FOR GAIN SETTINGS OF 0, 10 AND 20dB RESPECTIVELY. +Vs SEE TEXT FOR REMAINING TERMS. (+)
COUPLED POWER LINE NOISE VOLTAGE
(-)
* DENOTES FRONT PANEL ACCESS
AC POWER SUPPLY
VP
OR
INTERNAL BATTERIES
SIGNAL COMMON
3
1784 Chessie Lane, Ottawa, IL 61350 * Tel: 800/252-7074, 815/434-7800 * FAX: 815/434-8176 e-mail: sales@freqdev.com * Web Address: http://www.freqdev.com
Models 900CT & 900BT
Model 900 Series Front Panel Description
D E
Single Channel -
A B
Certified
C
Location of Front Panel Terminals and Controls
M
L
K
J
I
H
G
F
A. POWER Status Lamp: This red LED indicates whether or not the power to the analog filter circuitry of a Model 900CT/BT Series instrument is ON. With the power switch in the ON position, the LED glows continuously indicating internal DC power levels are correct. If LED does not light when power switch is in ON position, 1) reset instrument by cycling POWER switch OFF and ON, 2) Check line fuse.
D. CORNER FREQUENCY Selector Switch (0-9): This ten position rotary switch selects the 1's digit of the desired corner frequency between 0 and 9 in discrete increments of 1. E. MULTIPLIER Selector Switch: This fourposition rotary switch multiplies by a factor of either 0.1, 1.0, 10 or 100, the aggregate value set on the 3 CORNER FREQUENCY selector switches. (B, C & D) F. GAIN Switch: This three-position toggle switch selects an overall filter gain of 0, 10, or 20 dB. G. BYPASS Switch: OUT and IN setting of this two position toggle switch routes the input signal to the internal filter or around it, respectively. E.g. OUT position - no Bypass, the signal passes through the filter. In either case, the gain switch remains operational. H. INPUT Switch: This three position toggle configures the instrument for either differential inputs (A-B), a single-ended input (A), or input nulling ( ) which grounds both the (A) and (B) input terminals.
I. & J. (A) and (B) Input Terminals: This pair of shielded, female BNC connectors accept signal inputs (A) and (B). The instrument applies a non-inverting gain to input (A) and an equal but opposite inverting gain to input (B) while the GAIN switch sets the magnitude of differential gain to 0, 10, or 20 dB. The BNC shields have been internally connected to the instrument ground. K. GROUND ( ) Terminal: This "Banana" type test jack provides neat and secure access to the internal ground. This terminal is a convenient junction for grounding external system and measurement instrumentation and/or apparatus. L. OUT Terminal: This terminal is a female BNC connector. The shield on the BNC is internally connected to the instrument ground. M. OFFSET Adjust: This adjustment is intended to zero the offset that results from the instrument's own circuitry and does not provide for wide range offset to remove dc input signals.
For 900BT models only: If LED is flashing, recharge batteries, approximately 30 minutes of operation remains.
B. CORNER FREQUENCY Selector Switch (0-400Hz): This five position rotary switch selects the 100's digit of the corner frequency designator. The switch selectable values are 0, 100, 200, 300 and 400 in five discrete steps. C. CORNER FREQUENCY Selector Switch (0-90): This ten-position rotary switch selects the 10's digit of the desired corner frequency between 0 and 90, in discrete increments of 10.
4
1784 Chessie Lane, Ottawa, IL 61350 * Tel: 800/252-7074, 815/434-7800 * FAX: 815/434-8176 e-mail: sales@freqdev.com * Web Address: http://www.freqdev.com
Models 900CT & 900BT
Model 900 Series Rear Panel Description
Single Channel -
Certified
Location of Rear Panel Terminals, Controls and Labels
Model 900CT
Feb. 03 SELECT FUSE NOM. FREQ.
SN: 00101 115v (250v 1.0A) 60 Hz
900CT-9L8B 230v (250v 0.5A) 50 Hz
MADE IN U.S.A.
WARNING: Do not remove covers, no user serviceable parts inside. Contact : Frequency Devices for service, tech@freqdev.com
N
O
P
Model 900BT
Feb. 03 SELECT FUSE NOM. FREQ.
SN: 00102 115v (250v 1.0A) 60 Hz
900BT-9L8B 230v (250v 0.5A) 50 Hz
MADE IN U.S.A.
WARNING: Do not remove covers, no user serviceable parts inside. Contact : Frequency Devices for service, tech@freqdev.com
N. IDENTIFICATION LABEL: This label identifies the Model number, filter type, serial number, date of manufacture, operating power limits and fuse requirements of the instrument. O. AC POWER CONNECTION: Denotes plug and fuse location. P. POWER ON/OFF Switch: Is a twoposition toggle switch on the back panel that interrupts/completes the power circuit.
Q. VOLTAGE Selector Module: The power module window shows the operating voltage (115 Vac or 230 Vac). At time of shipment, the voltage window is set in the 115 Vac position. For 230 Vac operations, use a screwdriver blade to pry open the module door, remove the red fuse cartridge, turn it 180 degrees, reinsert and close the module door. The numerals 230 Vac will now show in the module window. Repeat procedure to change back to 115 Vac.
Q
F use h o ld e r
O p tio n a l s w itc h
5
1784 Chessie Lane, Ottawa, IL 61350 * Tel: 800/252-7074, 815/434-7800 * FAX: 815/434-8176 e-mail: sales@freqdev.com * Web Address: http://www.freqdev.com
Models 900CT & 900BT
8 Pole Low Pass Filters
900L8L 900L8E 900L8EY
8-Pole, 6 zero Elliptic 0.1 Hz to 49.9 kHz Appendix A Page 25 1 part in 499 within each decade -0.05 dB 0 0.1 dB typ. 0 0.2 dB max. -100 dB typ. fc 2% max. 0.5% typ. 2% max. 0.01%/C typ. 0.02%/C max. -0.05 dB -419 0.05 dB 3.01 dB 60.0 dB 80.0 dB 1.00 fr 1.06 fr 1.83 fr 2.00 fr
Single Channel -
Model
Transfer Function Range fc, fr Theoretical Transfer Characteristics Tuning Resolution Passband Ripple Pass Band Voltage Gain
(non-inverting)
Certified
900L8B
8-Pole Butterworth 0.1 Hz to 49.9 kHz Appendix A Page 9 1 part in 499 within each decade 0.0 dB 0 0.1 dB typ. 0 0.2 dB max. 48 dB/Octave fc 2% max. 0.5% typ. 2% max. 0.01%/C typ. 0.02%/C max. -3 dB -360 0.12 dB 3.01 dB 60.0 dB 80.0 dB 0.80 fc 1.00 fc 2.37 fc 3.16 fc
Filter Specifications 8-Pole 8-Pole, 6 zero Bessel Elliptic 0.1 Hz to 49.9 kHz Appendix A Page 4 1 part in 499 within each decade 0.0 dB 0 0.1 dB typ. 0 0.2 dB max. 48 dB/Octave fc 2% max. 0.5% typ. 2% max. 0.01%/C typ. 0.02%/C max. -3 dB -182 1.91 dB 3.01 dB 60.0 dB 80.0 dB 0.80 fc 1.00 fc 4.52 fc 6.07 fc 0.1 Hz to 49.9 kHz Appendix A Page 24 1 part in 499 within each decade 0.035 dB 0 0.1 dB typ. 0 0.2 dB max. -80 dB typ. fc 2% max. 0.5% typ. 2% max. 0.01%/C typ. 0.02%/C max. -0.035 dB -323 0.35 dB 3.01 dB 60.0 dB 80.0 dB 1.00 fr 1.13 fr 1.67 fr 1.77 fr
Stopband Attenuation Cutoff Frequency Accuracy
Stability Amplitude Phase Filter Attenuation
(theoretical)
Total Harmonic Distortion @ 1 kHz Wide Band Noise
(5 Hz - 2 MHz)
<-90 dB typ.
<-90 dB typ.
<-90 dB typ.
<-88 dB typ.
200Vrms typ. 50Vrms typ.
200Vrms typ. 50Vrms typ.
250Vrms typ. 75Vrms typ.
250Vrms typ. 75Vrms typ.
Narrow Band Noise
(5 Hz - 100 kHz)
6
1784 Chessie Lane, Ottawa, IL 61350 * Tel: 800/252-7074, 815/434-7800 * FAX: 815/434-8176 e-mail: sales@freqdev.com * Web Address: http://www.freqdev.com
Models 900CT & 900BT
8 Pole Low Pass Filters
900L8D10
8-Pole, 6 zero Constant Delay 0.1 Hz to 49.9 kHz Appendix A Page 22 1 part in 499 within each decade 0.15 dB 0 0.1 dB typ. 0 0.2 dB max. -100 dB typ. fc 2% max. 0.5% typ. 2% max. 0.01%/C typ. 0.02%/C max. -3 dB -311 3.01 dB 80.0 dB 100.0 dB 1.00 fc 4.45 fc 5.20 fc
Single Channel -
Model
Transfer Function Range fc Theoretical Transfer Characteristics Tuning Resolution Passband Ripple Pass Band Voltage Gain
(non-inverting)
Certified
900L8D80
Filter Specifications 8-Pole, 6 zero Constant Delay 0.1 Hz to 49.9 kHz Appendix A Page 21 1 part in 499 within each decade 0.15 dB 0 0.1 dB typ. 0 0.2 dB max. -80 dB typ. fc 2% max. 0.5% typ. 2% max. 0.01%/C typ. 0.02%/C max. -3 dB -306 3.01 dB 60.0 dB 80.0 dB 1.00 fc 3.08 fc 3.57 fc
Stopband Attenuation Cutoff Frequency Accuracy
Stability Amplitude Phase Filter Attenuation
(theoretical)
Total Harmonic Distortion @ 1 kHz Wide Band Noise
(5 Hz - 2 MHz)
<-90 dB typ.
<-88 dB typ.
200Vrms typ. 50Vrms typ.
200Vrms typ. 50Vrms typ.
Narrow Band Noise
(5 Hz - 100 kHz)
7
1784 Chessie Lane, Ottawa, IL 61350 * Tel: 800/252-7074, 815/434-7800 * FAX: 815/434-8176 e-mail: sales@freqdev.com * Web Address: http://www.freqdev.com
Models 900CT & 900BT
8 Pole High Pass Filters
900H8E 900H8EY
8-Pole, 6 zero Elliptic 0.1 Hz to 49.9 kHz Appendix A Page 38 1 part in 499 within each decade -0.05 dB
0 0.2 dB to.100kHz 0 0.5 dB to 120kHz.
Single Channel -
Model
Transfer Function Range fc, fr Theoretical Transfer Characteristics Tuning Resolution Passband Ripple Pass Band Voltage Gain
(non-inverting)
Certified
900H8B
Filter Specifications 8-Pole 8-Pole, 6 zero Butterworth Elliptic 0.1 Hz to 49.9 kHz Appendix A Page 29 1 part in 499 within each decade 0.0 dB
0 0.2 dB to.100kHz 0 0.5 dB to 120kHz.
0.1 Hz to 49.9 kHz Appendix A Page 37 1 part in 499 within each decade 0.035 dB
0 0.2 dB to.100kHz 0 0.5 dB to 120kHz.
Powert Bandwidth Stopband Attenuation Cutoff Frequency Accuracy
120 kHz 48 dB/Octave fc 2% max. 0.5% typ. 2% max. 0.01%/C typ. 0.02%/C max. -3 dB -360 80.0 dB 60.0 dB 3.01 dB 0.00 dB 0.31 fc 0.42 fc 1.00 fc 2.00 fc
120 kHz -80 dB typ. fc 2% max. 0.5% typ. 2% max. 0.01%/C typ. 0.02%/C max. -0.035 dB -323 80.0 dB 60.0 dB 3.01 dB 0.03 dB 0.00 dB 0.56 fr 0.60 fr 0.88 fr 1.00 fr 2.00 fr
120 kHz -100 dB typ. fc 2% max. 0.5% typ. 2% max. 0.01%/C typ. 0.02%/C max. -0.5 dB -419 100.0 dB 80.0 dB 3.01 dB 0.03 dB 0.00 dB 0.50 fr 0.55 fr 0.94 fr 1.00 fr 2.00 fr
Stability Amplitude Phase Filter Attenuation
(theoretical)
Total Harmonic Distortion @ 1 kHz Wide Band Noise
(5 Hz - 2 MHz)
<-88 dB typ.
<-88 dB typ.
<-88 dB typ.
400Vrms typ. 100Vrms typ.
400Vrms typ. 100Vrms typ.
500Vrms typ. 150Vrms typ.
Narrow Band Noise
(5 Hz - 100 kHz)
8
1784 Chessie Lane, Ottawa, IL 61350 * Tel: 800/252-7074, 815/434-7800 * FAX: 815/434-8176 e-mail: sales@freqdev.com * Web Address: http://www.freqdev.com
Models 900CT & 900BT
General Specifications
Single Channel -
Certified
Input Characteristics Input Impedance: Differential Single Ended Input Voltage: Linear Differential* Max Safe Differential Max Safe Common Mode Bias Current Common Mode Rejection ratio with 2k source unbalance and 0 dB Gain Output Characteristics Full Power Bandwidth** Related Output Short Circuit Output Current Output Protection Output Impedance Offset Voltage Power Supply AC Line Power Operation 900CT 900BT Voltage Frequency Range-Rear Panel: 115 V 230 V Fuse Battery Operation (900BT) Time for full Charge Battery Life Battery Charger Charge Status Indicator (Front Panel) Battery Operation Temperature Operating Temperature: Storage Temperature: Mechanical Dimensions Weight 900CT 900CT Case Material Color
2 M Shunted by 47pF 1 M Shunted by 47pF 20V p-p (Gain Set at 0 dB) Any Continuous Value between 100V Any Continuous Value between 50V 30 pA typ.; 175 pA max. > 60dB, DC to 50kHz DC to 600kHz 10V p-p for RL = 50 20V p-p for RL = 2k 100 mA continuous 200 mA without damage (Short Circuit to Ground Only) 50 Adjustable to Zero at Front Panel
(Range 500mV dc)
10 Watts max. 15 Watts max. 105 to 125Vac @ 50/60Hz 210 to 250Vac @ 50Hz 115 V=0.2 Amp., 230 V = 2X-0.1 Amp.
10 - 12 hours Approx. 500 Charge/Discharge Cycles Automatic Uninterruptible 3 Status Levels 6 Hours typ.
0 C to +50 C -25 C to +70 C
3.7"H x 8.66"W x 10.6"D 9.4cmH x 22.0cmW x 27.0cmD 3.5 lbs; 0.157 kgs 4.9 lbs; 0.219 kgs ABS plastic Light Gray
* Signal plus common mode voltage cannot exceed 20V peak to peak for a linear output. ** Output characteristics of input amplifier with filter in BYPASS mode.
9
1784 Chessie Lane, Ottawa, IL 61350 * Tel: 800/252-7074, 815/434-7800 * FAX: 815/434-8176 e-mail: sales@freqdev.com * Web Address: http://www.freqdev.com
Models 900CT & 900BT
Single Channel -
Certified
Ordering Information
A. AVAILABLE MODELS 1. 900CT 2. 900BT
Standard AC powered model 1 AC powered with battery powered option 1
FILTER TRANSFER FUNCTIONS AVAILABLE 2 B. LOW-PASS BUTTERWORTH 1. 900L8B BESSEL 2 900L8L ELLIPTIC 3. 900L8E 4. 900L8EY CONSTANT DELAY 5. 900L8D80 6. 900L8D10 C. HIGH PASS BUTTERWORTH ELLIPTIC
8-pole 8-pole 8-pole, 6 zero elliptic, 1.77, 80 dB 8-pole, 6 zero elliptic, 2.00, 100 dB 8-pole, constant delay 80 dB 8-pole, constant delay 100 dB
7. 8. 9.
900H8B 900H8E 900H8EY
8-pole 8-pole, 6 zero elliptic, 1.77, 80 dB 8-pole, 6 zero elliptic, 2.00, 100 dB
ORDERING INFORMATION
Filter Type L - Low - Pass H - High - Pass Transfer Function 2 B - Butterworth L - Bessel D80 - Constant Delay (-80dB) D10 - Constant Delay (-100dB) E - elliptic 1.77 (-80dB) EY - elliptic 2.00 (-100dB)
900CT/900L8L
Model
1
C - Standard AC Power B - AC Powered, with Battery Power Option
Poles 8
NOTE: 1.
2.
See page 5, item "Q" Voltage selector Module. At time of shipment, Voltage is pre-selected in the 115 VAC position. For 230 VAC operation, this module must be rotated 180 degrees and an additional fuse must be added. All filters tunable from 0.1 Hz to 49.9 kHz.
We hope the information given here will be helpful. The information is based on data and our best knowledge, and we consider the information to be true and accurate. Please read all statements, recommendations or suggestions herein in conjunction with our conditions of sale, which apply, to all goods supplied by us. We assume no responsibility for the use of these statements, recommendations or suggestions, nor do we intend them as a recommendation for any use, which would infringe any patent or copyright. IN-00900CT/BT-00
10
1784 Chessie Lane, Ottawa, IL 61350 * Tel: 800/252-7074, 815/434-7800 * FAX: 815/434-8176 e-mail: sales@freqdev.com * Web Address: http://www.freqdev.com
8-Pole
Bessel Appendix A Theoretical Transfer Characteristics 1 f/fc Amp Phase Delay (Hz) (dB) (deg) (sec) 0.00 0.00 0.00 .506 0.10 -0.029 -18.2 .506 0.20 -0.117 -36.4 .506 0.30 -0.264 -54.7 .506 0.40 -0.470 -72.9 .506 0.50 -0.737 -91.1 .506 0.60 -1.06 -109 .506 0.70 -1.45 -128 .506 0.80 -1.91 -146 .506 0.85 -2.16 -155 .506 0.90 -2.42 -164 .506 0.95 -2.71 -173 .506 1.00 -3.01 -182 .506 -3.67 1.10 -200 .506 -4.40 1.20 -219 .506 -5.20 1.30 -237 .506 1.40 -6.10 -255 .505 1.50 -7.08 -273 .504 1.60 -8.16 -291 .502 1.70 -9.36 -309 .498 1.80 -10.7 -327 .492 1.90 -12.1 -345 .482 2.00 -13.7 -362 .468 2.25 -18.1 -402 .417 2.50 -23.1 -436 .352 2.75 -28.3 -465 .291 3.00 -33.4 -489 .241 3.25 -38.3 -509 .201 3.50 -43.1 -526 .170 4.00 -51.8 -552 .126 5.00 -66.8 -587 .077 6.00 -79.2 -610 .052 7.00 -89.8 -626 .038 8.00 -99.0 -638 .029 9.00 -107 -647 .023 10.0 -114 -655 .018 Low-Pass Frequency Response 0 Amp (dB) -20 -40 -60 -80 -100 0.1
2
1.0 2 3 4 5 6 7 10.0 Normalized Frequency(f/fc)
3 4 5 6 78
Delay (Normalized) 1.0 Delay (sec)
0.5
0.0 0.1
0.15 2
3
4
5 6 7 89
Normalized Time (1/f sec)
1.0
1.5
Step Response Step Response (V/V) 1.2 1.0 0.8 0.6 0.4 0.2 -0.0 -0.2 0
1.Normalized Group Delay: The above delay data is normalized to a corner frequency of 1.0Hz.The actual delay is the normalized delay divided by the actual corner frequency (fc). Actual Delay = Normalized Delay Actual Corner Frequency (fc) in Hz
1
2
3
4
5
Normalized Time (1/f sec)
4
1784 Chessie Lane, Ottawa, IL 61350 * Tel: 800/252-7074, 815/434-7800 * FAX: 815/434-8176 e-mail: sales@freqdev.com Web Address: http://www.freqdev.com
Low-Pass
8-Pole Appendix A Theoretical Transfer Characteristics 1 f/fc Amp Phase Delay (Hz) (dB) (deg) (sec) 0.00 0.00 0.00 .816 0.10 0.00 -29.4 .819 0.20 0.00 -59.0 .828 0.30 0.00 -89.1 .843 0.40 0.00 -120 .867 0.50 0.00 -152 .903 0.60 -0.001 -185 .956 0.70 -0.014 -221 1.04 0.80 -0.121 -261 1.19 0.85 -0.311 -283 1.29 0.90 -0.738 -307 1.40 0.95 -1.58 -333 1.48 1.00 -3.01 -360 1.46 1.10 -7.48 -408 1.17 1.20 -12.9 -445 .873 1.30 -18.2 -472 .672 1.40 -494 .540 -23.4 1.50 -511 .448 -28.2 1.60 -526 .380 -32.7 1.70 -539 .328 -36.9 1.80 -550 .287 -40.8 1.90 -44.6 -560 .253 2.00 -48.2 -568 .226 2.25 -56.3 -586 .174 2.50 -63.7 -600 .139 2.75 -70.3 -611 .113 3.00 -76.3 -621 .094 3.25 -81.9 -629 .080 3.50 -87.1 -635 .069 4.00 -96.3 -646 .052 5.00 -112 -661 .033 6.00 -125 -671 .023 7.00 -135 -678 .017 8.00 -144 -683 .013 9.00 -153 -687 .010 10.0 -160 -691 .008 Butterworth Frequency Response 0 Amp (dB) -20 -40 -60 -80 -100 0.1
2 3 4 5 6 78 1.0 2 3 4 5 67
10.0
Normalized Frequency(f/fc) Delay (Normalized) 2.0 Delay (sec)
1.0
0.0 0.1
0.15 2
3
4
5 6 7 8 9 1.0 1.5
Normalized Time (1/f sec)
Step Response Step Response (V/V) 1.2 1.0 0.8 0.6 0.4 0.2 -0.0 0 1 2 3 4 Normalized Time (1/f sec) 5
1.Normalized Group Delay: The above delay data is normalized to a corner frequency of 1.0Hz.The actual delay is the normalized delay divided by the actual corner frequency (fc). Actual Delay = Normalized Delay Actual Corner Frequency (fc) in Hz
9
1784 Chessie Lane, Ottawa, IL 61350 * Tel: 800/252-7074, 815/434-7800 * FAX: 815/434-8176 e-mail: sales@freqdev.com Web Address: http://www.freqdev.com
8-Pole, 6-Zero
Constant Delay Appendix A Theoretical Transfer Characteristics 1 f/fc Amp Phase Delay (Hz) (dB) (deg) (sec) 0.00 0.00 .852 0.00 0.017 -30.7 .852 0.10 0.058 -61.3 .852 0.20 0.099 -92.0 .852 0.30 0.105 -123 .852 0.40 0.034 -153 .852 0.50 -0.157 -184 .852 0.60 -0.510 -215 .852 0.70 -1.07 -245 .851 0.80 -1.44 -261 .850 0.85 -1.89 -276 .849 0.90 -2.41 -291 .846 0.95 -3.01 -306 .841 1.00 -4.50 -336 .821 1.10 -6.39 -365 .783 1.20 -11.3 -417 .656 1.40 -17.1 -459 .512 1.60 -23.2 -492 .396 1.80 -29.1 -517 .312 2.00 -36.3 -542 .239 2.25 2.50 -43.4 -561 .189 2.75 -50.3 -576 .153 3.00 -57.6 -589 .127 3.25 -62.5 -599 .107 3.50 -75.4 -608 .092 3.75 -98.3 -616 .079 4.00 -86.3 -442 .069 4.25 -84.1 -448 .061 4.50 -85.1 -454 .054 4.75 -87.9 -458 .049 5.00 -92.8 -462 .044 5.25 -104 -466 .040 5.50 -101 -289 .036 5.75 -93.3 -293 .033 6.00 -89.9 -295 .030 -86.6 -300 .026 6.50 -85.1 -305 .022 7.00 -84.1 -312 .017 8.00 -84.3 -317 .013 9.00 -84.9 -321 .011 10.0
1.Normalized Group Delay: The above delay data is normalized to a corner frequency of 1.0Hz.The actual delay is the normalized delay divided by the actual corner frequency (fc). Actual Delay = Normalized Delay Actual Corner Frequency (fc) in Hz
Low-Pass (80 dB) Frequency Response 0 Amp (dB) -20 -40 -60 -80 -100 0.1
2
1.0 2 3 4 5 6 7 10.0 Normalized Frequency(f/fc)
3 4 5 6 78
Delay (Normalized) 1.0 Delay (sec)
0.5
0.0 0.1
0.15 2
1.0 1.5 Normalized Time (1/f sec)
3
4
5 6 7 89
Step Response Step Response (V/V) 1.2 1.0 0.8 0.6 0.4 0.2 -0.0 -0.2 0
1
2 3 4 Normalized Time (1/f sec)
5
21
1784 Chessie Lane, Ottawa, IL 61350 * Tel: 800/252-7074, 815/434-7800 * FAX: 815/434-8176 e-mail: sales@freqdev.com Web Address: http://www.freqdev.com
8-Pole, 6-Zero
Constant Delay Appendix A Theoretical Transfer Characteristics 1 f/fc Amp Phase Delay (Hz) (dB) (deg) (sec) 0.00 0.00 0.00 .865 0.10 0.015 -31.1 .865 .865 0.20 0.051 -62.3 .865 0.30 0.085 -93.4 .865 0.40 0.085 -125 0.50 0.010 -156 .865 0.60 -0.182 -187 .865 0.70 -0.532 -218 .865 0.80 -1.09 -249 .864 0.85 -1.45 -265 .863 0.90 -1.89 -280 .861 0.95 -2.41 -296 .857 1.00 -3.01 -311 .851 1.10 -4.50 -341 .828 1.20 -6.38 -370 .785 1.40 -11.2 -422 .650 1.60 -16.8 -464 .504 1.80 -22.5 -496 .389 2.00 -28.0 -520 .306 2.25 -34.5 -544 .235 2.50 -40.5 -563 .186 2.75 -46.1 -578 .151 3.00 -51.4 -591 .125 3.50 -61.5 -610 .090 4.00 -71.2 -624 .068 4.50 -81.3 -635 .054 5.00 -93.4 -643 .043 5.50 -142 -651 .036 6.00 -105 -476 .030 6.20 -105 -478 .028 6.50 -106 -481 .025 7.00 -110 -486 .022 8.00 -122 -312 .017 9.00 -109 -318 .013 10.0 -106 -322 .011 12.0 -105 -328 .007 14.0 -106 -333 .005 16.0 -107 -336 .004 18.0 -108 -339 .003 20.0 -109 -341 .003
1.Normalized Group Delay: The above delay data is normalized to a corner frequency of 1.0Hz.The actual delay is the normalized delay divided by the actual corner frequency (fc). Actual Delay = Normalized Delay Actual Corner Frequency (fc) in Hz
Low-Pass (100 dB) Frequency Response 0 -20 Amp (dB) -40 -60 -80 -100 -120 0.1
2 3 4 5 678
1.0 10.0 Normalized Frequency(f/fc)
2
3 4 5 67
Delay (Normalized) 1.0 Delay (sec)
0.5
0.0 0.1
0.15 2
1.0 1.5 Normalized Time (1/f sec)
3
4
5 6 7 89
Step Response Step Response (V/V) 1.2 1.0 0.8 0.6 0.4 0.2 -0.0 -0.2 0
1
2 3 4 Normalized Time (1/f sec)
5
22
1784 Chessie Lane, Ottawa, IL 61350 * Tel: 800/252-7074, 815/434-7800 * FAX: 815/434-8176 e-mail: sales@freqdev.com Web Address: http://www.freqdev.com
8-Pole, 6-Zero
Elliptic, 1.77 Appendix A Theoretical Transfer Characteristics 1 f/fc Amp Phase Delay (Hz) (dB) (deg) (sec) 0.00 0.00 0.00 0.713 0.10 -0.004 -25.7 0.716 0.20 -0.014 -51.6 0.724 0.30 -0.024 -77.9 0.740 0.40 -0.020 -105 0.767 0.50 0.007 -133 0.811 0.55 0.022 -148 0.840 0.60 0.033 -163 0.872 0.65 0.031 -179 0.908 0.70 0.014 -196 0.946 0.75 -0.015 -213 0.989 0.80 -0.041 -232 1.04 0.85 -0.046 -251 1.12 0.90 -0.016 -272 1.23 0.95 -0.025 -296 1.40 1.00 -0.035 -323 1.65 1.10 -1.76 -392 2.14 1.20 -8.28 -467 1.86 1.30 -18.4 -522 1.19 1.40 -29.3 -558 0.753 1.50 -40.1 -578 0.517 1.60 -51.5 -594 0.381 1.70 -65.2 -606 0.296 1.75 -75.0 -611 0.265 1.80 -113.0 -616 0.239 1.85 -83.6 -440 0.217 1.90 -82.0 -444 0.198 1.95 -83.7 -447 0.182 2.00 -87.8 -450 0.168 2.20 -85.8 -280 0.126 2.40 -82.0 -289 0.099 2.60 -83.5 -295 0.081 2.80 -88.2 -301 0.067 3.00 -99.9 -305 0.057 3.50 -87.2 -134 0.040 4.00 -83.1 -140 0.030 5.00 -82.1 -148 0.018 6.00 -83.1 -154 0.013 7.00 -84.6 -157 0.009 8.00 -86.2 -160 0.007 9.00 -87.8 -163 0.005 10.0 -89.3 -164 0.004
1.Normalized Group Delay: The above delay data is normalized to a corner frequency of 1.0Hz.The actual delay is the normalized delay divided by the actual corner frequency (fc). Normalized Delay Actual Delay = Actual Corner Frequency (fc) in Hz
Low-Pass Frequency Response 0 Amp (dB) -20 -40 -60 -80 -100 0.1
2
1.0 2 3 4 5 6 7 10.0 Normalized Frequency(f/fc)
3 4 5 6 78
Delay (Normalized) 4.0 Delay (sec)
2.0 0.8 0.0 0.1
0.15 2
1.0 1.5 Normalized Time (1/f sec)
3
4
5 6 7 89
Step Response Step Response (V/V) 1.2 1.0 0.8 0.6 0.4 0.2 -0.0 0 1 2 3 4 Normalized Time (1/f sec) 5
24
1784 Chessie Lane, Ottawa, IL 61350 * Tel: 800/252-7074, 815/434-7800 * FAX: 815/434-8176 e-mail: sales@freqdev.com Web Address: http://www.freqdev.com
8-Pole, 6-Zero
Elliptic, 2.00 Appendix A Theoretical Transfer Characteristics 1 f/fc Amp Phase Delay (Hz) (dB) (deg) (sec) 0.00 0.00 0.00 0.885 0.10 -0.001 -31.9 0.891 0.20 -0.015 -64.2 0.903 0.30 -0.040 -97.0 0.922 0.40 -0.042 -131 0.958 0.50 -0.001 -166 1.020 0.55 0.000 -185 1.057 0.60 -0.007 -204 1.099 0.65 -0.027 -225 1.140 0.70 -0.045 -245 1.193 0.75 -0.040 -268 1.269 0.80 -0.014 -291 1.377 0.85 -0.001 -317 1.513 0.90 -0.031 -346 1.677 0.95 -0.036 -378 1.960 1.00 -0.046 -419 2.681 1.10 -7.910 -525 2.127 1.20 -21.06 -573 0.856 1.30 -31.96 -597 0.509 1.40 -41.51 -612 0.357 1.50 -50.35 -623 0.271 1.60 -58.90 -632 0.216 1.70 -67.54 -639 0.177 1.75 -72.04 -642 0.162 1.80 -76.79 -645 0.149 1.85 -81.93 -647 0.138 1.90 -87.78 -650 0.128 1.95 -95.04 -652 0.119 2.00 -106.6 -654 0.111 2.20 -106.0 -481 0.087 2.40 -121.3 -307 0.070 2.60 -106.5 -311 0.058 2.80 -105.0 -315 0.049 3.00 -106.4 -318 0.042 3.50 -123.6 -325 0.030 4.00 -111.5 -149 0.022 5.00 -105.4 -156 0.014 6.00 -105.1 -160 0.010 7.00 -106.0 -163 0.007 8.00 -107.3 -165 0.005 9.00 -108.6 -167 0.004 10.0 -110.0 -168 0.003
1.Normalized Group Delay: The above delay data is normalized to a corner frequency of 1.0Hz.The actual delay is the normalized delay divided by the actual corner frequency (fc). Normalized Delay Actual Delay = Actual Corner Frequency (fc) in Hz
Low-Pass Frequency Response 0 -20 Amp (dB) -40 -60 -80 -100 -120 0.1
2
1.0 2 3 4 5 6 7 10.0 Normalized Frequency(f/fc)
3 4 5 6 78
Delay (Normalized) 4.0 Delay (sec)
2.0 0.8 0.0 0.1
0.15 2
1.0 1.5 Normalized Time (1/f sec)
3
4
5 6 7 89
Step Response Step Response (V/V) 1.2 1.0 0.8 0.6 0.4 0.2 -0.0 0 1 2 3 4 Normalized Time (1/f sec) 5
25
1784 Chessie Lane, Ottawa, IL 61350 * Tel: 800/252-7074, 815/434-7800 * FAX: 815/434-8176 e-mail: sales@freqdev.com Web Address: http://www.freqdev.com
High-Pass
8-Pole Appendix A Theoretical Transfer Characteristics 1 f/fc Amp Phase Delay (Hz) (dB) (deg) (sec) 0.10 -160 691 0.819 0.20 -112 661 0.828 0.30 -83.7 631 0.843 0.40 -63.7 600 0.867 0.50 -48.2 568 0.903 0.60 -35.5 535 .956 499 0.70 -24.8 1.04 459 0.80 -15.6 1.19 437 0.85 -11.6 1.29 413 0.90 -8.06 1.40 0.95 -5.15 386 1.48 360 1.00 -3.01 1.46 275 1.20 -0.229 0.873 226 1.40 -0.020 0.540 -0.002 194 1.60 0.380 170 1.80 0.00 0.287 152 0.00 2.00 0.226 0.139 120 0.00 2.50 0.00 99.2 0.094 3.00 0.052 0.00 74.0 4.00 5.00 0.00 59.0 0.033 49.0 0.023 6.00 0.00 0.00 42.1 0.017 7.00 0.00 36.8 0.013 8.00 0.00 32.7 0.010 9.00 10.0 0.00 29.4 0.008 Butterworth Frequency Response 0 Amp (dB) -20 -40 -60 -80 -100 0.1
2
1.0 2 3 4 5 6 7 10.0 Normalized Frequency(f/fc)
3 4 5 6 78
1.Normalized Group Delay: The above delay data is normalized to a corner frequency of 1.0Hz.The actual delay is the normalized delay divided by the actual corner frequency (fc). Actual Delay = Normalized Delay Actual Corner Frequency (fc) in Hz
29
1784 Chessie Lane, Ottawa, IL 61350 * Tel: 800/252-7074, 815/434-7800 * FAX: 815/434-8176 e-mail: sales@freqdev.com Web Address: http://www.freqdev.com
8-Pole, 6-Zero
Elliptic, 1.77 Appendix A Theoretical Transfer Characteristics 1 f/fc Amp Phase Delay (Hz) (dB) (deg) (sec) 0.10 -89.3 164 0.440 0.20 -82.1 148 0.459 0.30 -90.6 131 0.495 292 0.40 -82.4 0.559 -87.8 450 0.50 0.671 0.55 -90.0 0.761 437 -60.2 0.60 0.890 603 -32.4 0.70 1.37 563 -13.1 0.80 2.35 498 -6.28 0.85 2.77 451 0.90 -2.21 401 2.66 358 0.95 -0.51 2.15 324 1.00 -0.03 1.64 277 1.10 -0.01 1.04 225 1.20 -0.05 0.757 1.30 -0.03 221 0.596 1.40 0.01 201 0.486 1.50 0.03 185 0.409 1.60 0.03 172 0.347 1.70 0.03 160 0.299 1.80 0.02 150 0.260 1.90 0.01 141 0.229 2.00 0.01 133 0.203 2.50 -0.02 105 0.123 3.00 -0.02 86.9 0.083 4.00 -0.02 64.7 0.046 5.00 -0.01 51.6 0.029 6.00 -0.01 42.9 0.020 -0.01 0.015 7.00 36.8 -0.01 0.011 8.00 32.1 9.00 -0.01 28.6 0.009 10.0 0.00 25.7 0.007 High-Pass Frequency Response 0 Amp (dB) -20 -40 -60 -80 -100 0.1
2 3 4 5 6 78 1.0 2 3 4 5 67
10.0
Normalized Frequency(f/fc)
1.Normalized Group Delay: The above delay data is normalized to a corner frequency of 1.0Hz.The actual delay is the normalized delay divided by the actual corner frequency (fc). Normalized Delay Actual Delay = Actual Corner Frequency (fc) in Hz
37
1784 Chessie Lane, Ottawa, IL 61350 * Tel: 800/252-7074, 815/434-7800 * FAX: 815/434-8176 e-mail: sales@freqdev.com Web Address: http://www.freqdev.com
8-Pole, 6-Zero
Elliptic, 2.00 Appendix A Theoretical Transfer Characteristics 1 f/fc Amp Phase Delay (Hz) (dB) (deg) (sec) 0.10 -110 168 0.338 -105 0.20 156 0.348 -114 0.30 323 0.367 309 -110 0.40 0.397 654 -107 0.50 0.445 0.55 -78.6 646 0.480 0.524 0.60 -64.6 637 0.669 0.70 -44.1 615 1.001 0.80 -26.7 586 1.401 0.85 -18.2 565 0.90 -9.46 533 2.315 0.95 -2.16 478 3.604 1.00 -0.046 419 2.681 1.416 1.10 -0.038 352 1.018 1.20 -0.001 308 1.30 -0.032 277 0.773 1.40 -0.046 252 0.618 1.50 -0.034 231 0.514 1.60 -0.016 214 0.436 1.70 -0.004 200 0.376 1.80 0.000 187 0.328 1.90 -0.003 176 0.288 2.00 166 -0.010 0.255 131 2.50 -0.042 0.153 108 3.00 -0.045 0.103 4.00 -0.028 80.6 0.057 64.2 5.00 -0.015 0.036 53.4 6.00 -0.008 0.025 45.7 7.00 -0.005 0.018 40.0 8.00 -0.003 0.014 9.00 -0.002 35.5 0.011 31.9 10.0 -0.001 0.009 High-Pass Frequency Response 0 -20 Amp (dB) -40 -60 -80 -100 -120 0.1
2
1.0 2 3 4 5 6 7 10.0 Normalized Frequency(f/fc)
3 4 5 6 78
1.Normalized Group Delay: The above delay data is normalized to a corner frequency of 1.0Hz.The actual delay is the normalized delay divided by the actual corner frequency (fc). Normalized Delay Actual Delay = Actual Corner Frequency (fc) in Hz
38
1784 Chessie Lane, Ottawa, IL 61350 * Tel: 800/252-7074, 815/434-7800 * FAX: 815/434-8176 e-mail: sales@freqdev.com Web Address: http://www.freqdev.com


▲Up To Search▲   

 
Price & Availability of 900BT

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X