www.murata-ps.com
PRODUCT OVERVIEW
OKX T/10 & T/16-W5 Series
Adjustable DOSA 10/16-Amp SIP DC/DC Converters
Typical unit
The OKX-T/10 and -T/16 series are miniature SIP non-isolated Point-of-Load (POL) DC/DC power converters for embedded applications. The module is fully compatible with Distributed-power Open Standards Alliance (DOSA) industry-standard specifications (www.dosapower.com). Applications include powering CPU's, datacom/telecom systems, programmable logic and mixed voltage systems. The wide input range is 2.4 to 5.5 Volts DC. Two maximum output currents are offered, 10 Amps (T/10 models) or 16 Amps (T/16 models). Based on fixed-frequency synchronous buck converter
switching topology, the high power conversion efficient Point of Load (POL) module features programmable output voltage and On/Off control. An optional Sequence/Tracking input allows controlled ramp-up and ramp-down outputs. The Sense input provides load compensation. These converters also include under voltage lock out (UVLO), output short circuit protection, over-current and over temperature protections. These units are designed to meet all standard UL/EN/IEC 60950-1 safety certifications and RoHS6 hazardous substance compliance.
FEATURES
Non-isolated SIP POL DC/DC power module 2.4-5.5Vdc input voltage range Programmable output voltage from 0.7525-3.63Vdc 10 Amp (T/10) or 16 Amp (T/16) output current models Drives 1000 F ceramic capacitive loads High power conversion efficiency 95% at 3.3 Vout Outstanding thermal derating performance Over temperature and over current protection On/Off control, Sense and optional Sequence/ Tracking input UL/EN/IEC 60950-1 safety Industry-standard (DOSA) SIP format RoHS-6 hazardous substance compliance Connection Diagram
+Vin F1 +Vout
Contents of full data sheet Page Description, Connection Diagram, Photograph 1 Ordering Guide, Model Numbering 2 Mechanical Specifications, Input/Output Pinout 3 Detailed Electrical Specifications 5 Output Voltage Adjustment, Soldering Guidelines, Product Label 6 Application Notes 7 OKX-T/10-W5 Performance Data 10 OKX-T/16-W5 Oscillograms and Performance Data 11
On/Off Control
Sense Controller
External DC Power Source
Trim Open = On Closed = Off (Positive On/Off) Common Reference and Error Amplifier
Common
Sequence/Tracking (optional)
Figure 1. OKX2-T/10, -T/16 Note: Murata Power Solutions strongly recommends an external input fuse, F1. See specifications.
For full details go to www.murata-ps.com/rohs
www.murata-ps.com
19 Oct 2009
email: sales@murata-ps.com
MDC_OKX_T10T16-W5 Series.A01_short Page 1 of 4
This data sheet contains core information only. Please click here for the full data sheet.
OKX T/10 & T/16-W5 Series
Adjustable DOSA 10/16-Amp SIP DC/DC Converters
Performance Specifications and Ordering Guide
ORDERING GUIDE
Output Input Iin, no load (mA) Iin, full load (Amps) Efficiency Min. Typ. Pos. Neg. 6.91 5 2.4-5.5 94.0% 95.5% Pos. Neg 80 5 2.4-5.5 Pos. Neg. 11.12 5 2.4-5.5 93.0% 95.0% Pos. Neg. yes yes 2.0x0.5x0.37 (50.8x12.7x9.4) 2.0x0.5x0.37 (50.8x12.7x9.4) no no 2.0x0.5x0.37 (50.8x12.7x9.4) 2.0x0.5x0.37 (50.8x12.7x9.4) yes yes 2.0x0.5x0.37 (50.8x12.7x9.4) 2.0x0.5x0.37 (50.8x12.7x9.4) no no On/Off Sequence/ Polarity Tracking Package C86, Pinout P84 Case
Dimensions are in inches (mm)
Model Number OKX-T/10-W5P-C
VOUT (Volts)
0.7525-3.63
Regulation (Max.) IOUT R/N (Amps Power (mVp-p) Vin Nom. Range max) (Watts) Max. f Line Load (Volts) (Volts) 10 5 2.4-5.5
2.0x0.5x0.37 (50.8x12.7x9.4) 2.0x0.5x0.37 (50.8x12.7x9.4)
OKX-T/10-W5N-C
0.7525-3.63
10 33 25 0.2%
5
2.4-5.5
OKX2-T/10-W5P-C 0.7525-3.63
10
OKX2-T/10-W5N-C 0.7525-3.63
10 0.5%
5
2.4-5.5
OKX-T/16-W5P-C
0.7525-3.63
16
OKX-T/16-W5N-C
0.7525-3.63
16 52.8 30 0.3%
5
2.4-5.5
OKX2-T/16-W5P-C 0.7525-3.63
16
OKX2-T/16-W5N-C 0.7525-3.63

16
5
2.4-5.5

The input voltage range must be 0.5V greater than the output voltage. All specifications are at nominal line voltage, Vout=nominal (3.3V for W5 models) and full load, +25 deg.C. unless otherwise noted. Output capacitors are 1 F ceramic and 10 F electrolytic in parallel. Input cap is 22 F. See detailed specifications. I/O caps are necessary for our test equipment and may not be needed for your application.
Use adequate ground plane and copper thickness adjacent to the converter. Ripple and Noise (R/N) is shown at Vout=1V. See specs for details.
PART NUMBER STRUCTURE
OK X 2 - T / 16 - W5 P J - C
Okami Non-isolated PoL SIP Mount Sequence/Tracking Blank = Not installed, delete pin 9 2 = Installed, add pin 9 Trimmable Output Voltage Range W5 Models = 0.7525-3.63V Maximum Rated Output Current in Amps Reversed Pin Mounting (see pg. 4) J = Reversed Pins (special order) Blank = Standard Pins On/Off Polarity P = Positive Polarity N = Negative Polarity Input Voltage Range W5 = 2.4-5.5V Note: Some model number combinations may not be available. See Ordering Guide above. Contact Murata Power Solutions for availability. RoHS Hazardous Substance Compliance C = RoHS-6 (does not claim EU RoHS exemption 7b-lead in solder)
www.murata-ps.com
19 Oct 2009
email: sales@murata-ps.com
MDC_OKX_T10T16-W5 Series.A01_short Page 2 of 4
This data sheet contains core information only. Please click here for the full data sheet.
OKX T/10 & T/16-W5 Series
Adjustable DOSA 10/16-Amp SIP DC/DC Converters
MECHANICAL SPECIFICATIONS, STANDARD MODELS
51.3 2.02 48.26 1.900 12.70 .500 2.54 .100 TYP 4.45 .175 35.56 1.400 10.16 .400 .060 .060 1.02 .040 (x10 or 11*) 1.52 .060
Pin 1 2 3 4 5
10.16 .400
I/O CONNECTIONS Function Pin Function + Output 6 Common + Output 7 + Input +Sense In 8 + Input + Output 9* *Sequence/Tracking Common 10 Trim 11 On/Off Control
*Sequence/Tracking is optional. If not installed, Pin 9 is omitted.
11 10 9* 8 7 6 5 4 3 2 1
RECOMMENDED FOOTPRINT -TOP VIEW
50.8 2.00
9.4 .37 MAX 5.1 .20 REF
Dimensions are in inches (mm shown for ref. only).
Third Angle Projection
12.7 .50
11 10 9* 8 7 6 5 4 3 2 1
4.3 .17 2.54 .100 TYP 10.16 .400 35.56 1.400 1.27 .050 1.5 .06 0.76 .030 TYP
12.70 .500 MATERIAL: PINS: COPPER ALLOY FINISH: (ALL PINS) PINS: TIN
Tolerances (unless otherwise specified): .XX 0.02 (0.5) .XXX 0.010 (0.25) Angles 1 Components are shown for reference only.
SHIPPING LABEL
555.8 21.88
TUBE LENGTH
TEN (10) UNITS PER TUBE
20.975 BETWEEN BARRELS OF PINS (REF)
20.8 0.82 REF
SHIPPING TUBES
15.9 0.63 REF
www.murata-ps.com
19 Oct 2009
email: sales@murata-ps.com
MDC_OKX_T10T16-W5 Series.A01_short Page 3 of 4
This data sheet contains core information only. Please click here for the full data sheet.
OKX T/10 & T/16-W5 Series
Adjustable DOSA 10/16-Amp SIP DC/DC Converters
MECHANICAL SPECIFICATIONS, CONTINUED: "J" PACKAGE OPTION (REVERSED HEADERS)
51.3 2.02 48.26 1.900 12.70 .500 2.54 .100 TYP 35.56 1.400 10.16 .400 1.02 .040 (x10 or 11*) 1.52 .060
8.6 .34
7.9 .31
11 10 9* 8 7 6 5 4 3 2 1
Pin 1 2 3 4 5
I/O CONNECTIONS Function Pin Function + Output 6 Common + Output 7 + Input +Sense In 8 + Input + Output 9* *Sequence/Tracking Common 10 Trim 11 On/Off Control
*Sequence/Tracking is standard for OKX2. On OKX models, Pin 9 is omitted.
RECOMMENDED FOOTPRINT -TOP VIEW
9.7 .38 MAX 50.8 2.00 7.9 .31
Dimensions are in inches (mm shown for ref. only).
Third Angle Projection
12.7 .50
3.3 .13
11 10
9* 8
7
6
5
4
3
2
1
12.70 .500
2.54 .100 TYP
10.16 .400 35.56 1.400 1.27 .050
0.76 .030 TYP 1.27 .050
Tolerances (unless otherwise specified): .XX 0.02 (0.5) .XXX 0.010 (0.25) Angles 1 Components are shown for reference only.
MATERIAL: PINS: COPPER ALLOY FINISH: (ALL PINS) PINS: TIN
Murata Power Solutions, Inc. 11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A.
ISO 9001 and 14001 REGISTERED
Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without notice. (c) 2009 Murata Power Solutions, Inc.
www.murata-ps.com/locations
19 Oct 2009
email: sales@murata-ps.com
MDC_OKX_T10T16-W5 Series.A01_short Page 4 of 4


▲Up To Search▲   

 
Price & Availability of OKX2-T10-W5N-C

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X