Part Number Hot Search : 
TD62107P HGTG40N6 DS1869 UPD72 LSC2B TS6121E INTEGRA WRB4805
Product Description
Full Text Search
 

To Download UEP-33-6000-D48 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 Single Output UEP Models
Ultra-High Density, 2" x 1", 1.2-6 Amp,15-30 Watt DC/DC's
FEATURES
n
PRODUCT OVERVIEW
The UEP Series DC/DC Converters deliver the most power/current (up to 30W/6Amps) from a 1" x 2" package. And because of their footprint compatibility, they can be used as drop in replacements for their bigger brothers, the standard 2" x 2" and 1.6" x 2" devices, commonly used in the industry. By combining a high-frequency (340kHz), high-efficiency (to 89%), synchronous-rectifier topology with the newest components and time-tested, fully automated, SMT-on-pcb construction, these UEP Models are able to bring you 15-30W in the standard 2" x 1" package from which most competitors can only get 5-10W. All UEP's deliver their full output power over ambient temperature ranges from -40C to as high as +70C (model and input voltage dependent) without heat sinks or supplemental forced-air cooling. Devices derate to +100C. Output voltages are 3.3, 5, 12 or 15 Volts. Input voltage ranges are 10-18V ("D12" models), 18-36V ("D24" models) or 36-75V ("D48") models. All models feature input pi filters, input undervoltage and overvoltage lockout, input reverse-polarity protection, output overvoltage protection, output current
Choice of 3 input ranges: 10-18V, 18-36V, 36-75V Models Include 3.3V @ 4.5A or 6A 5V @ 3.5A or 6A 15V @ 1.2A 12V @ 1.4A Guaranteed efficiencies to 89% 15-30 Watts in 1" x 2" package 340kHz synchronous-rectifier topologies -40 to +60/70C ambient w/o derating Fully isolated (1500Vdc); I/O protected Trim and On/Off Control UL1950/EN60950 certified CE mark (75VIN models)
n
n n n n n n n n
limiting, and continuous short-circuit protection. Standard features also include on/off control and output-trim. All models are certified to IEC950, UL1950 and EN60950 safety requirements for OPERATIONAL insulation. "D48" models (36-75V inputs) are CE marked. UEP Series DC/DC's are packaged in low-cost, light-weight, diallyl phthalate (UL94V-0 rated) plastic packages with standoffs. EMC compliance is achieved via a lownoise design rather than through expensive metal shielding.
For full details go to www.murata-ps.com/rohs
+INPUT (1)
+OUTPUT (4)
SWITCH CONTROL
-OUTPUT (5)
-INPUT (2)
PWM CONTROLLER UVLO & OVLO COMPARATORS ON/OFF CONTROL (3)
OPTO ISOLATION
REFERENCE & ERROR AMP
TRIM (6)
3.3V and 5V-output models use the synchronous-rectifier configuration shown above.
12V and 15V-output models employ a standard, diode-rectification architecture.
Figure 1. Simplified Schematic Typical topology is shown.
www.murata-ps.com
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000
MDC_UEP Models.A02 Page 1 of 11
Single Output UEP Models
Ultra-High Density, 2" x 1", 1.2-6 Amp,15-30 Watt DC/DC's
Performance Specifications and Ordering Guide Output Model UEP-3.3/4500-D12 UEP-3.3/4500-D24 UEP-3.3/4500-D48 UEP-3.3/6000-D48 UEP-5/3500-D12 UEP-5/3500-D24 UEP-5/3500-D48 UEP-5/6000-D48 UEP-12/1400-D12 UEP-12/1400-D24 UEP-12/1400-D48 UEP-15/1200-D12 UEP-15/1200-D24 Vout (Volts) 3.3 3.3 3.3 3.3 5 5 5 5 12 12 12 15 15 Iout (mA) 4500 4500 4500 6000 3500 3500 3500 6000 1400 1400 1400 1200 1200 R/N (mVp-p) Typ. 85 85 85 85 85 85 85 85 85 85 85 85 85 Max. 100 100 100 100 100 100 100 100 100 100 100 100 100 Regulation (Max.) Line 0.2% 0.2% 0.2% 0.2% 0.2% 0.2% 0.2% 0.2% 0.2% 0.2% 0.2% 0.2% 0.2% Load 0.5% 0.5% 0.5% 0.3% 0.5% 0.5% 0.5% 0.3% 0.5% 0.5% 0.5% 0.5% 0.5% Vin Nom. (Volts) 12 24 48 48 12 24 48 48 12 24 48 12 24 Input Range (Volts) 10-18 18-36 36-75 36-75 10-18 18-36 36-75 36-75 10-18 18-36 36-75 10-18 18-36 Vout (mA) 80/1490 50/730 35/360 40/470 120/1760 65/850 40/430 35/710 60/1650 45/800 20/400 60/1760 45/860 Efficiency Min. 83.5% 85.5% 85.5% 86% 84% 86% 86% 88% 82.5% 85% 85% 82.5% 85% Typ. 84.5% 87.5% 87.5% 88% 86% 88% 88% 91% 85% 87% 87% 85% 87% Package (Case, Pinout) C15, P21 C15, P21 C15, P21 C15, P21 C15, P21 C15, P21 C15, P21 C15, P21 C15, P21 C15, P21 C15, P21 C15, P21 C15, P21
Typical at TA = +25C under nominal line voltage and full-load conditions, unless otherwise noted. Ripple/Noise (R/N) is tested/specifed over a 20MHz bandwidth. All models are specified with no external input/output capacitors.
Load regulation is specified over no load to 100% load conditions for 3.3 and 5Vout models, 25mA to 100% load conditions for 12 and 15 Vout models. Nominal line voltage, no-load/full-load conditions.
PART NUMBER STRUCTURE
MECHANICAL SPECIFICATIONS
2.00 (50.80) PLASTIC CASE 0.49 (12.45)
U EP - 3.3 / 4500 - D48 N - C
Output Configuration: U = Unipolar External Pinout ROHS-6 Hazardous Substance Compliance N Suffix Available for 12Vout and 15Vout Models Input Voltage Range: D12 = 10-18 Volts (12V nominal) D24 = 18-36 Volts (24V nominal) D48 = 36-75 Volts (48V nominal) Maximum Output Current in mA
1.00 (25.40)
Case C15
STANDOFF 0.020 (0.51)
0.20 MIN (5.08)
0.040 0.001 DIA. (1.016 0.025) 1.800 (45.72) 1 2 0.600 (15.24) 3 0.10 (2.54)
Nominal Output Voltage: 3.3, 5, 12 or 15 Volts
4 5 0.400 (10.16) 0.800 (20.32)
0.400 (10.16)
6 0.100 (2.54) BOTTOM VIEW
0.10 (2.54)
DIMENSIONS ARE IN INCHES (MM)
Optional Functions UEP converters are designed such that the 12 and 15Vout models can be configured for either positive logic on/off control (no suffix) or negative logic ("N" suffix). 3.3 and 5Vout models are available with positive logic only (no suffix). No Suffix On/Off Control function (positive polarity) on pin 3 N On/Off Control function (negative polarity) on pin 3. (12V and 15V models only.)
I/O Connections Pin 1 2 3 4 5 6 Function P21 +Input -Input On/Off Control +Output -Output Trim
www.murata-ps.com
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000
MDC_UEP Models.A02 Page 2 of 11
Single Output UEP Models
Ultra-High Density, 2" x 1", 1.2-6 Amp,15-30 Watt DC/DC's
Performance/Functional Specifications
Typical @ TA = +25C under nominal line voltage and full-load conditions, unless noted.
Input
Input Voltage Range: D12 Models D24 Models D48 Models Overvoltage Shutdown: D12 Models D24 Models D48 Models Start-Up Threshold: D12 Models D24 Models D48 Models Undervoltage Shutdown: D12 Models D24 Models D48 Models Input Current: Normal Operating Conditions Standby Mode (Off, OV, UV) Input Filter Type Reverse-Polarity Protection On/Off Control (Optional, Pin 3): D12, D24, & D48 Models D12N, D24N, & D48N Models 10-18 Volts (12V nominal) 18-36 Volts (24V nominal) 36-75 Volts (48V nominal) 18.5-21 Volts (20V typical) 37-40 Volts (38V typical) 77-81 Volts (78.5V typical) 9.3-9.8 Volts (9.6V typical) 16.5-18 Volts (17V typical) 34-36 Volts (35V typical) 7-8.5 Volts (8V typical) 15.5-17.5 Volts (16.5V typical) 32.5-35.5 Volts (34.5V typical) See Ordering Guide 5mA Pi Brief duration, 10A maximum On = open or 13V - +VIN, IIN = 50A max. Off = 0-0.8V, IIN = 1mA max. On = 0-0.5V, IIN = 50A max. Off = open or 2.4-10V, IIN = 3.7mA max. Switching Frequency 6A Models 1.2A-4.5A Models
Dynamic Characteristics (continued)
400kHz (20kHz) 340kHz (40kHz)
Environmental
Operating Temperature (Ambient): Without Derating With Derating Case Temperature: Maximum Allowable Storage Temperature Dimensions Shielding Case Material Pin Material Weight

-40 to +60/70C to +100C (See Derating Curves) +100C -40 to +105C
Physical
2" x 1" x 0.51" (51 x 25 x 12.95mm) None Diallyl phthalate, (UL94V-0 rated) Gold-plated copper alloy with nickel underplate 1.4 ounces (39.7 grams)
Output
VOUT Accuracy (50% load): Minimum Loading: 3.3V/5V Outputs 12V/15V Outputs Ripple/Noise (20MHz BW) Line/Load Regulation Efficiency Isolation Voltage: Input-to-Output Isolation Capacitance Isolation Resistance Current Limit Inception: 6A Models 4.5A Models 3.5A Models 1.4A Models 1.2A Models Short Circuit: Average Current VOUT Trim Range Overvoltage Protection Temperature Coefficient Transient Response (50-100% load) Start-Up Time: VIN to VOUT On/Off to VOUT 1.5%, maximum No load 25mA See Ordering Guide See Ordering Guide See Ordering Guide 1500Vdc minimum 470pF 100MW 7-8 Amps 5.5-7 Amps (6.25 Amps typ.) 5.5-6 Amps (5.25 Amps typ.) 1.9-2.7 Amps (2.3 Amps typ.) 1.5-2.1 Amps (1.8 Amps typ.) Hiccup, indefinite 3 Amps maximum 5% Zener/transorb clamp, magnetic feedback 0.02% per C.Dynamic Characteristics
All models are specified with no external input/output capacitors. See Minimum Output Loading Requirements under Technical Notes. See Technical Notes for details. The On/Off Control is designed to be driven with open-collector logic or the application of appropriate voltages (referenced to -Input (Pin 2)). Applying a voltage to the On/Off Control pin when no input voltage is applied to the converter may cause permanent damage. See Technical Notes. Output noise may be further reduced with the addition of external output capacitors. See Technical Notes. Operating temperature range without derating is model and input-voltage dependent. See Temperature Derating. UEP-3.3/600-D48 and UEP-5/6000-D48 do not have overvoltage shutdown. See Absolute Maximum Ratings for allowable input voltages.
Absolute Maximum Ratings
Input Voltage: Continuous: D12 Models D24 Models D48 Models Transient (100msec): D12 Models D24 Models D48 Models Input Reverse-Polarity Protection Output Overvoltage Protection: 3.3V Outputs 5V/12V/15V Outputs Output Current Case Temperature Storage Temperature Lead Temperature (soldering, 10 sec.)
22 Volts 44 Volts 88 Volts 22 Volts 44 Volts 88 Volts Current must be <10 Amps. Brief duration only. Fusing recommended. 4.5 Volts, unlimited duration 6.8/15/18 Volts, unlimited duration Hiccup. Devices can withstand sustained output short circuits without damage. +100C -40 to +105C +300C
Dynamic Characteristics
300sec max. to 1.5% of final value 50msec 30msec
These are stress ratings. Exposure of devices to any of these conditions may adversely affect long-term reliability. Proper operation under conditions other than those listed in the Performance/Functional Specifications Table is not implied.
www.murata-ps.com
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000
MDC_UEP Models.A02 Page 3 of 11
Single Output UEP Models
Ultra-High Density, 2" x 1", 1.2-6 Amp,15-30 Watt DC/DC's
TECHNICAL NOTES Floating Outputs Since these are isolated DC/DC converters, their outputs are "floating." Designers will usually use the -Output (pin 5) as the ground/return of the load circuit. You can, however, use the +Output (pin 4) as ground/return to effectively reverse the output polarity. Minimum Output Loading Requirements 3.3 and 5V models employ a synchronous-rectifier design topology. All models regulate within spec and are stable under no-load conditions. 12/15V models employ a traditional forward, diode-rectification architecture and require 25mA loading to achieve their listed regulation specs. Operation under 25mA load conditions will not damage the 12/15V devices; however they may not meet all listed specifications. Filtering and Noise Reduction All UEP Series DC/DC Converters achieve their rated ripple and noise specifications with no external input/output capacitors. In critical applications, input/output noise may be further reduced by installing external I/O caps. Input capacitors should be selected for bulk capacitance, low ESR and high rms-ripple-current ratings. Output capacitors should be selected for low ESR and appropriate frequency response. All caps should have appropriate voltage ratings and be mounted as close to the converters as possible. The most effective combination of external I/O capacitors will be a function of load and layout conditions. Our Applications Engineers can recommend potential solutions and discuss the possibility of our modifying a given device's internal filtering to meet your specific requirements. Contact our Applications Engineering Group for additional details. Input Fusing Certain applications and/or safety agencies may require the installation of fuses at the inputs of power conversion components. Fuses should also be used if the possibility of sustained, non-current-limited, input-voltage polarity reversals exists. For DATEL UEP Series DC/DC Converters, you should use slow-blow type fuses with values no greater than the following. VIN Range D12 Models D24 Models D48 Models (1.2-4.5A) D48 Models (6A) Fuse Value 3 Amps 2 Amps 1 Amp 2 Amp
1 +OUTPUT 4 +INPUT
2
-INPUT
TRIM
6
20k 5-22 Turns
LOAD
3
ON/OFF CONTROL
-OUTPUT
5
Figure 2. Trim Connections Using A Trim Pot
1
+INPUT
+OUTPUT
4 RTRIM DOWN
2
-INPUT
TRIM
6
LOAD
3
ON/OFF CONTROL
-OUTPUT
5
Figure 3. Trim Connections To Decrease Output Voltage Using Fixed Resistors
1
+INPUT
+OUTPUT
4
2
-INPUT
TRIM
6
LOAD RTRIM UP
3
ON/OFF CONTROL
-OUTPUT
5
Figure 4. Trim Connections To Increase Output Voltage Using Fixed Resistors
Model
UEP-3.3/4500-D12 UEP-3.3/4500-D24 UEP-3.3/4500-D48 UEP-3.3/6000-D48 UEP-5/3500-D12 UEP-5/3500-D24 UEP-5/3500-D48 UEP-5/6000-D48 UEP-12/1400-D12 UEP-12/1400-D24 UEP-12/1400-D48
Trim Equation
RTDOWN (k) = RTUP (k) = RTDOWN (k) = RTUP (k) = RTDOWN (k) = RT UP (k) = RTDOWN (k) = RTUP (k) = 2.49(VO - 1.27) 3.3 - VO 3.16 VO - 3.3 -16.9 -16.9
2.49(VO - 2.527) -15 5 - VO 6.292 VO - 5 -15
Trimming Output Voltages These converters have a trim capability (pin 6) that allows users to adjust the output voltage 5%. Adjustments to the output voltage can be accomplished via a trim pot, Figure 2, or a single fixed resistor as shown in Figures 3 and 4. A single fixed resistor can increase or decrease the output voltage depending on its connection. Fixed resistors should have an absolute TCR less than 100ppm/C to minimize sensitivity to changes in temperature. A single resistor connected from the Trim (pin 6) to the +Output (pin 4), see Figure 3, will decrease the output voltage. A resistor connected from the Trim (pin 6) to -Output (pin 5) will increase the output voltage. Trim adjustment greater than 5% can have an adverse effect on the converter's performance and is not recommended.
6.34(VO - 5.714) -49.9 12 - VO 36.23 VO - 12 -49.9
UEP-15/1200-D12 UEP-15/1200-D24 UEP-15/1200-D48
7.87(VO - 7.136) -63.4 15 - VO 56.16 VO - 15 -63.4
Accuracy of adjustment is subject to tolerances of resistor values and factoryadjusted output accuracy. Vo = desired output voltage.
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000
www.murata-ps.com
MDC_UEP Models.A02 Page 4 of 11
Single Output UEP Models
Ultra-High Density, 2" x 1", 1.2-6 Amp,15-30 Watt DC/DC's
Input Overvoltage/Undervoltage Shutdown and Start-Up Threshold Under normal start-up conditions, devices will not begin to regulate until the ramping-up input voltage exceeds the Start-Up Threshold Voltage (35V for "D48" models). Once operating, devices will not turn off until the input voltage drops below the Undervoltage Shutdown limit (34V for "D48" models). Subsequent re-start will not occur until the input is brought back up to the Start-Up Threshold. This built in hysteresis prevents any unstable on/off situations from occurring at a single input voltage. Input voltages exceeding the input overvoltage shutdown specification listed in the Performance/Functional Specifications will cause the device to shutdown. A built-in hysteresis of 0.6 to 1.6 Volts for all models will not allow the converter to restart until the input voltage is sufficiently reduced. The two 6 Amp models do not feature overvoltage shutdown and withstand surges to 100V without shutting down. For custom overvoltage protection, contact DATEL. Input Reverse-Polarity Protection If the input-voltage polarity is accidentally reversed, an internal diode will become forward biased and likely draw excessive current from the power source. If the source is not current limited (<10A) nor the circuit appropriately fused, it could cause permanent damage to the converter. On/Off Control The input-side, remote On/Off Control function (pin 3) can be ordered to operate with either polarity (negative polarity available for 12 and 15 Volt models only). Positive-polarity devices (standard, no part-number suffix) are enabled when pin 3 is left open or is pulled high (+13V to VIN applied with respect to -Input, pin 2, (see Figure 2). Positive-polarity devices are disabled when pin 3 is pulled low (0-0.8V with respect to -Input). Negative-polarity devices are off when pin 3 is open or pulled high (+2.4V to +10V), and on when pin 3 is pulled low (0-0.5V). See Figure 3.
1 +INPUT
3 ON/OFF CONTROL
2
-INPUT
Figure 3. Driving the Negative Polarity On/Off Control Pin
Dynamic control of the remote on/off function is best accomplished with a mechanical relay or an open-collector/open-drain drive circuit (optically isolated if appropriate). The drive circuit should be able to sink appropriate current (see Performance Specs) when activated and withstand appropriate voltage when deactivated. Applying an external voltage to pin 3 when no input power is applied to the converter can cause permanent damage to the converter. Start-Up Time The VIN to VOUT start-up time is the interval of time where the input voltage crosses the turn-on threshold point, and the fully loaded output voltage enters and remains within its specified accuracy band. Actual measured times will vary with input source impedance, external input/output capacitance, and load. The UEP Series implements a soft start circuit that limits the duty cycle of the PWM controller at power up, thereby limiting the Input Inrush current. The On/Off Control to VOUT start-up time assumes the converter has its nominal input voltage applied but is turned off via the On/Off Control pin. The specification defines the interval between the time at which the converter is turned on and the fully loaded output voltage enters and remains within its specified accuracy band. Similar to the VIN to VOUT start-up, the On/Off Control to VOUT start-up time is also governed by the internal soft start circuitry and external load capacitance. Current Limiting When output increases to 120% to 190% of the rated output current, the DC/DC converter will go into a current limiting mode. In this condition the output voltage will decrease proportionately with increases in output current, thereby maintaining a somewhat constant power dissipation. This is commonly referred to as power limiting. Current limit inception is defined as the point where the full-power output voltage falls below the specified tolerance. See Performance/Functional Specifications. If the load current being drawn from the converter is significant enough, the unit will go into a short circuit condition. See "Short Circuit Condition."
1
+INPUT 200k
13V CIRCUIT
3 ON/OFF CONTROL 5V CIRCUIT
2
-INPUT
Figure 2. Driving the Positive Polarity On/Off Control Pin
www.murata-ps.com
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000
MDC_UEP Models.A02 Page 5 of 11
Single Output UEP Models
Ultra-High Density, 2" x 1", 1.2-6 Amp,15-30 Watt DC/DC's
Short Circuit Condition When a converter is in current limit mode the output voltages will drop as the output current demand increases. If the output voltage drops too low, the magnetically coupled primary side voltages will also drop, thereby shutting down the PWM controller. Following a time-out period, the PWM will restart, causing the output voltage to begin ramping to its appropriate value. If the short-circuit condition persists, another shutdown cycle will be initiated. This on/off cycling is referred to as "hiccup" mode. The hiccup cycling reduces the average output current, thereby preventing internal temperatures from rising to excessive levels. The UEP is capable of enduring an indefinite short circuit output condition. Thermal Shutdown These UEP converters are equipped with Thermal Shutdown Circuitry. If environmental conditions cause the internal temperature of the DC/DC converter rises above the designed operating temperature (typically 118C case), a precision temperature sensor will power down the unit. When the internal temperature decreases below the threshold of the temperature sensor the unit will self start. Output Overvoltage Protection Output voltages are monitored for an overvoltage condition via magnetic coupling to the primary side. If the output voltage should rise to a level which could be damaging to the load circuitry, the sensing circuitry will power down the PWM controller causing the output voltages to decrease. Following a time-out period the PWM will restart, causing the output voltages to ramp to their appropriate values. If the fault condition persists, and the output voltage again climbs to excessive levels, the overvoltage circuitry will initiate another shutdown cycle. This on/off cycling is referred to as "hiccup" mode.
Typical Performance Curves
Temperature Derating Curves for UEP-3.3/4500 Output Models
17.5 VIN = 18V-27V (D24) 15 VIN = 36V-48V (D48)
12.5
Output Power (Watts)
10 VIN = 18V-30V (D24) VIN = 36V-60V (D48) 7.5 VIN = 12V (D12) 5 VIN = 18V-36V (D24) VIN = 36V-75V (D48) 2.5
0
-40
0
40
45
50
55
60
65
70
75
80
85
90
95
100
Ambient Temperature (C)
www.murata-ps.com
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000
MDC_UEP Models.A02 Page 6 of 11
Single Output UEP Models
Ultra-High Density, 2" x 1", 1.2-6 Amp,15-30 Watt DC/DC's
Typical Performance Curves
Temperature Derating Curves for UEP-3.3/6000-D48
21
UEP-3.3/4500-D48 Efficiency vs. Line Voltage and Load Current 90
18
VIN = 36V
85 80
15
Output Power (Watts)
Efficiency (%)
75 70 65 60 55
VIN = 48V VIN = 36V
12
VIN = 75V
9 VIN = 48V 6
3
50 45
-40 0 40 45 50 55 60 65 70 75 80 85 90 95 100
VIN = 75V
0
0.4
0.91
1.43
1.94
2.45
2.96
3.48
3.99
4.5
Ambient Temperature (C)
Load Current (Amps)
UEP-3.3/6000-D48 Efficiency vs. Line Voltage and Load Current 90 85 80 Efficiency (%) 75 70 65 60 55 50 45 1
VIN = 75V VIN = 48V VIN = 36V
2
3
4
5
6
Load Current (Amps)
www.murata-ps.com
7
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000
MDC_UEP Models.A02 Page 7 of 11
Single Output UEP Models
Ultra-High Density, 2" x 1", 1.2-6 Amp,15-30 Watt DC/DC's
Typical Performance Curves
Temperature Derating Curves for UEP-5/3500 Output Models
20 VIN = 18V-27V (D24) 17.5 VIN = 36V-48V (D48) 28 VIN = 36V-48V 32
Temperature Derating Curves for UEP-5/6000-D48
15
24
Output Power (Watts)
Output Power (Watts)
12.5 VIN = 18V-30V (D24) VIN = 36V-60V (D48)
20
10
16
7.5
12
VIN = 12V (D12) VIN = 18V-36V (D24) VIN = 36V-75V (D48)
VIN = 75V
5
8
2.5
4
0 -40 0 40 45 50 55 60 65 70 75 80 85 90 95 100
0 -40 0 40 45 50 55 60 65 70 75 80 85 90 95 100
Ambient Temperature (C)
Ambient Temperature (C)
www.murata-ps.com
8
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000
MDC_UEP Models.A02 Page 8 of 11
Single Output UEP Models
Ultra-High Density, 2" x 1", 1.2-6 Amp,15-30 Watt DC/DC's
Typical Performance Curves
UEP-5/3500-D48 Efficiency vs. Line Voltage and Load Current 90 85 80 75 70 65 60 55 50 45 40 0.3 0.7 1.1 1.5 1.9 2.3 2.7 3.1 3.5
VIN = 75V VIN = 48V VIN = 36V
Output Power (Watts)
18
Temperature Derating Curves for 12V Output Models
VIN = 18V-27V (D24) 16 14 12 10 8 6 4 2 0 -40 0 40 45 50 55 60 65 70 75 80 85 90 95 100 VIN = 12V (D12) VIN = 18V-36V (D24) VIN = 36V-75V (D48) VIN = 18V-30V (D24) VIN = 36V-60V (D48) VIN = 36V-48V (D48)
Efficiency (%)
Load Current (Amps)
Ambient Temperature (C)
UEP-5/6000-D48 Efficiency vs. Line Voltage and Load Current 95 90 85 Efficiency (%) 80 75 70 65 60 55
VIN = 75V VIN = 36V
VIN = 48V
1
2
3
4
5
6
Load Current (Amps)
www.murata-ps.com
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000
MDC_UEP Models.A02 Page 9 of 11
Single Output UEP Models
Ultra-High Density, 2" x 1", 1.2-6 Amp,15-30 Watt DC/DC's
Typical Performance Curves
UEP-12/1400-D48 Efficiency vs. Line Voltage and Load Current 90 85 80 Efficiency (%) 75 70 65 60 55
VIN = 75V VIN = 48V VIN = 36V
50 45 0.10 0.26 0.43 0.59 0.75 0.91 1.06 1.24 1.40
Load Current (Amps)
Temperature Derating Curves for 15V Output Models
20 18 16 14 VIN = 18V-27V (D24) VIN = 36V-48V (D48)
UEP-15/1200-D48 Efficiency vs. Line Voltage and Load Current 90 85 80
Output Power (Watts)
12 10 8
VIN = 18V-30V (D24) VIN = 36V-60V (D48)
Efficiency (%)
75 70 65 60 55 50 0.10
VIN = 75V VIN = 36V
VIN = 12V (D12) 6 4 2 0 VIN = 18V-36V (D24) VIN = 36V-75V (D48)
VIN = 48V
-40
0
40
45
50
55
60
65
70
75
80
85
90
95
100
0.24
0.38
0.51
0.65
0.79
0.93
1.06
1.2
Ambient Temperature (C)
Load Current (Amps)
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000
www.murata-ps.com
MDC_UEP Models.A02 Page 10 of 11
1 5 - 3 0 W, S I N G L E O U T P U T D C / D C C O N V E RT E R S
Single Output UEP Models
Ultra-High Density, 2" x 1", 1.2-6 Amp,15-30 Watt DC/DC's
Typical Performance Curves
Output Ripple and Noise (PARD)
(VIN = nominal, 3.3V @ 4.5A, no external capacitors.)
Output Ripple and Noise (PARD)
(VIN = nominal, 12V @ 1.4A, no external capacitors.)
20mV/div, 20MHz BW
20mV/div, 20MHz BW
Output Ripple and Noise (PARD)
(VIN = nominal, 5V @ 3.5A, no external capacitors.)
Output Ripple and Noise (PARD)
(VIN = nominal, 15V @ 1.2A, no external capacitors.)
20mV/div, 20MHz BW
20mV/div, 20MHz BW
USA: Canada: UK: France:
Tucson (AZ), Tel: (800) 547 2537, email: sales@murata-ps.com Toronto, Tel: (866) 740 1232, email: toronto@murata-ps.com Milton Keynes, Tel: +44 (0)1908 615232, email: mk@murata-ps.com Montigny Le Bretonneux, Tel: +33 (0)1 34 60 01 01, email: france@murata-ps.com Tokyo, Tel: 3-3779-1031, email: sales_tokyo@murata-ps.com Osaka, Tel: 6-6354-2025, email: sales_osaka@murata-ps.com Website: www.murata-ps.jp Shanghai, Tel: +86 215 027 3678, email: shanghai@murata-ps.com Guangzhou, Tel: +86 208 221 8066, email: guangzhou@murata-ps.com
Murato Power Solutions, Inc. 11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A. Tel: (508) 339-3000 (800) 233-2765 Fax: (508) 339-6356
www.murata-ps.com
ISO 9001 REGISTERED
Germany: Munchen, Tel: +49 (0)89-544334-0, email: ped.munich@murata-ps.com Japan:
email: sales@murata-ps.com
DS-0502B 2/14/08
China:
(c) 2008 Murata Power Solutions, Inc. Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without notice.
www.murata-ps.com
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000
MDC_UEP Models.A02 Page 11 of 11


▲Up To Search▲   

 
Price & Availability of UEP-33-6000-D48

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X