![]() |
|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
AP2186/AP2196 1.5A DUAL CHANNEL CURRENT-LIMITED POWER SWITCH Features * * * * * * * * * * * * * * * * Dual USB port power switches Over-current and thermal protection 2.1A accurate current limiting Reverse Current Blocking 90m on-resistance Input voltage range: 2.7V - 5.5V 0.6ms typical rise time Very low shutdown current: 1uA (max) Fault report (FLG) with blanking time (7ms typ) ESD protection: 6KV HBM, 300V MM Active high (AP2196) or active low (AP2186) enable Ambient temperature range -40C to 85C SOP-8L and MSOP-8L-EP (Exposed Pad): Available in "Green" Molding Compound (No Br, Sb) Lead Free Finish / RoHS Compliant (Note 1) UL Recognized, File Number E322375 IEC60950-1 CB Scheme Certified Description The AP2186 and AP2196 are integrated high-side power switches optimized for Universal Serial Bus (USB) and other hot-swap applications. The family of devices complies with USB 2.0 and available with both polarities of Enable input. They offer current and thermal limiting and short circuit protection as well as controlled rise time and under-voltage lockout functionality. A 7ms deglitch capability on the open-drain Flag output prevents false over-current reporting and does not require any external components. All devices are available in SOP-8L and MSOP-8L-EP packages. Applications * * * Consumer electronics - LCD TV & Monitor, Game Machines Communications - Set-Top-Box, GPS, Smartphone Computing - Laptop, Desktop, Servers, Printers, Docking Station, HUB Typical Application Circuit Power Supply 2.7V to 5.5V 10k 10k 10uF 0.1uF FLG1 FLG2 ON OFF EN1 EN2 GND OUT2 0.1uF 68uF IN OUT1 0.1uF 68uF Load Load Available Options Part Number AP2186 AP2196 Channel 2 2 Enable Pin (EN) Active Low Active High Current Limit (Typical) 2.1A 2.1A Recommended Maximum Continuous Load Current 1.5A 1.5A AP2186/AP2196 Rev 1 1 of 17 www.diodes.com APRIL 2009 (c) Diodes Incorporated AP2186/AP2196 1.5A DUAL CHANNEL CURRENT-LIMITED POWER SWITCH Ordering Information AP 21 X 6 XX G - 13 Enable 8 : Active Low 9 : Active High Device AP21X6SG-13 AP21X6MPG-13 Notes: Channel 6 : 2 Channel Package S : SOP-8L MP : MSOP-8L-EP Green G : Green Packing 13 : Tape & Reel Package Code S MP Packaging (Note 2) SOP-8L MSOP-8L-EP 13" Tape and Reel Quantity Part Number Suffix 2500/Tape & Reel -13 2500/Tape & Reel -13 1. EU Directive 2002/95/EC (RoHS). All applicable RoHS exemptions applied. Please visit our website at http://www.diodes.com/products/lead_free.html 2. Pad layout as shown on Diodes Inc. suggested pad layout document AP02001, which can be found on our website at http://www.diodes.com/datasheets/ap02001.pdf. Pin Assignment ( Top View ) EN1 FLG1 1 2 8 7 6 5 ( Top View ) OUT1 IN GND OUT2 EN1 FLG1 FLG2 EN2 1 2 3 4 8 7 6 5 OUT1 IN GND OUT2 FLG2 3 EN2 4 MSOP-8L-EP SOP-8L AP2186/AP2196 Rev 1 2 of 17 www.diodes.com APRIL 2009 (c) Diodes Incorporated AP2186/AP2196 1.5A DUAL CHANNEL CURRENT-LIMITED POWER SWITCH Pin Descriptions Pin Name EN1 FLG1 FLG2 EN2 OUT2 GND IN OUT1 Pin Number 1 2 3 4 5 6 7 8 Descriptions Switch 1 enable input, active low (AP2186) or active high (AP2196) Switch 1 over-current and over-temperature fault report, open-drain Switch 2 over-current and over-temperature fault report, open-drain Switch 2 enable input, active low (AP2186) or active high (AP2196) Switch 2 voltage output pin Ground Voltage input pin Switch 1 voltage output pin Functional Block Diagram FLG 1 T h e rm a l S ense D e g litc h EN1 D riv e r U VLO C u rre n t L im it GND CS R e v e rs e b lo c k in g OUT1 IN R e v e rs e b lo c k in g CS OUT2 U VLO D riv e r C u rre n t L im it D e g litc h FLG 2 EN2 T h e rm a l S ense GND AP2186/AP2196 Rev 1 3 of 17 www.diodes.com APRIL 2009 (c) Diodes Incorporated AP2186/AP2196 1.5A DUAL CHANNEL CURRENT-LIMITED POWER SWITCH Absolute Maximum Ratings Symbol ESD HBM ESD MM VIN VOUT VEN , VFLG Iload TJmax TST Notes: Parameter Human Body Model ESD Protection Machine Model ESD Protection Input Voltage Output Voltage Enable Voltage Maximum Continuous Load Current Maximum Junction Temperature Storage Temperature Range (Note 3) Ratings 6 300 6.5 VIN + 0.3 6.5 Internal Limited 150 -65 ~ 150 Units KV V V V V A C C 3. UL Recognized Rating from -30C to 70C Recommended Operating Conditions Symbol VIN IOUT TA Parameter Input voltage Output Current Operating Ambient Temperature Min 2.7 0 -40 Max 5.5 1.5 85 Units V A C AP2186/AP2196 Rev 1 4 of 17 www.diodes.com APRIL 2009 (c) Diodes Incorporated AP2186/AP2196 1.5A DUAL CHANNEL CURRENT-LIMITED POWER SWITCH Electrical Characteristics (TA = 25 C, CIN=10F, VIN = +5.0V, unless otherwise stated) o Symbol VUVLO ISHDN IQ ILEAK IREV Parameter Input UVLO Input Shutdown Current Input Quiescent Current, Dual Input Leakage Current Reverse Leakage Current RDS(ON) Switch on-resistance ISHORT ILIMIT ITrig Short-circuit current limit Over-Load Current Limit Current limiting trigger threshold TSHORT Short-circuit Response Time VIL VIH ISINK TD(ON) TR TD(OFF) TF RFLG IFOH TBlank TSHDN THYS JA Notes: EN Input Logic Low Voltage EN Input Logic High Voltage EN Input leakage Output turn-on delay time Output turn-on rise time Output turn-off delay time Output turn-off fall time FLG output FET on-resistance Error Flag Off Current FLG blanking time Thermal shutdown threshold Thermal shutdown hysteresis Thermal Resistance Junction-to-Ambient Test Conditions Rload=1k Disabled, IOUT= 0 Enabled, IOUT= 0 Disabled, OUT grounded Disabled, VIN = 0V, VOUT = 5V, IREV at VIN MSOP-8L-EP VIN = 5V, IOUT= 1.5A, -40oC TA 85oC SOP-8L MSOP-8L-EP VIN = 3.3V, IOUT= 1.5A, -40oC TA 85oC SOP-8L Enabled into short circuit, CL= 68F VIN = 5V, VOUT = 4.5V, MSOP-8L-EP CL=120F, -40oC TA SOP-8L 85oC VIN = VEN, Output Current Slew rate (<100A/s), CL=68F VOUT = 0V to IOUT = ILIMIT (short applied to output), CL = 68F VIN = 2.7V to 5.5V VIN = 2.7V to 5.5V VEN = 5V CL=1F, Rload=10 CL=1F, Rload=10 CL=1F, Rload=10 CL=1F, Rload=10 IFLG =10mA VFLG=5V CL=68F Enabled, Rload=1k SOP-8L (Note 4) MSOP-8L-EP (Note 5) Min 1.6 Typ. 1.9 0.5 95 1 90 100 120 2.1 Max 2.5 1 140 1 135 135 160 Unit V A A A A m m m A 1.6 2.1 2.5 20 2.6 A A s 0.8 2 1 0.05 0.6 0.01 0.05 20 4 0.01 7 140 25 125 60 1.5 0.1 40 1 15 V V A ms ms ms ms A ms C C o C/W o C/W 4. Test condition for SOP-8L: Device mounted on FR-4 2-layer board, 2oz copper, with minimum recommended pad layout. 5. Test condition for MSOP-8L-EP: Device mounted on FR-4 2-layer board, 2oz copper, with minimum recommended pad on top layer and 3 vias to bottom layer ground plane. AP2186/AP2196 Rev 1 5 of 17 www.diodes.com APRIL 2009 (c) Diodes Incorporated AP2186/AP2196 1.5A DUAL CHANNEL CURRENT-LIMITED POWER SWITCH Typical Performance Characteristics VEN 50% 50% VEN TD(OFF) TF 50% 50% TR TD(ON) VOUT 10% 90% TR TD(ON) VOUT 10% 90% TD(OFF) TF 90% 10% CL=1uF TA=25C RL=5 90% 10% Figure 1. Voltage Waveforms: AP2186 (left), AP2196 (right) All Enable Plots are for AP2196 Active High Channel 1 Turn-Off Delay and Fall Time Channel 1 Turn-On Delay and Rise Time Ven 1 5V/div Ven 1 5V/div Vout 1 2V/div Vout 1 2V/div CL=1uF TA=25C RL=5 CL=1uF TA=25C RL=5 400us/div Channel 2 Turn-On Delay and Rise Time 400us/div Channel 2 Turn-Off Delay and Fall Time Ven 2 5V/div Ven 2 5V/div Vout 2 2V/div Vout 2 2V/div CL=1uF TA=25C RL=5 CL=1uF TA=25C RL=5 400us/div 400us/div AP2186/AP2196 Rev 1 6 of 17 www.diodes.com APRIL 2009 (c) Diodes Incorporated AP2186/AP2196 1.5A DUAL CHANNEL CURRENT-LIMITED POWER SWITCH Typical Performance Characteristics Channel 1 Turn-On Delay and Rise Time (Continued) Channel 1 Turn-Off Delay and Fall Time Ven 2 5V/div Ven 2 5V/div CL=100uF Vout 2 2V/div CL=100uF TA=25C RL=5 Vout 2 2V/div TA=25C RL=5 400us/div Channel 2 Turn-On Delay and Rise Time 400us/div Channel 2 Turn-Off Delay and Fall Time Ven 2 5V/div Ven 2 5V/div CL=100uF Vout 2 2V/div CL=100uF TA=25C RL=5 Vout 2 2V/div TA=25C RL=5 400us/div Channel 1 Short Circuit Current, Device Enabled Into Short Ven 1 5V/div Ven 2 5V/div 400us/div Channel 2 Short Circuit Current, Device Enabled Into Short Iout 1 500mA/div VIN=5V TA=25C CL=68uF Iout 2 500mA/div VIN=5V TA=25C CL=68uF 500us/div 500us/div AP2186/AP2196 Rev 1 7 of 17 www.diodes.com APRIL 2009 (c) Diodes Incorporated AP2186/AP2196 1.5A DUAL CHANNEL CURRENT-LIMITED POWER SWITCH Typical Performance Characteristics Channel 1 Inrush Current Ven 1 5V/div CL=100uF CL=470uF VIN=5V TA=25C RL=3.3 (Continued) Channel 2 Inrush Current Ven 2 5V/div CL=100uF CL=470uF VIN=5V TA=25C RL=3.3 Iout 1 500mA/div Iout 2 500mA/div CL=220uF CL=220uF 1ms/div Channel 1 0.6 Load Connected to Enabled Device VIN=5V TA=25C Vflag 1 2V/div CL=68uF Vflag 2 2V/div 1ms/div Channel 2 0.6 Load Connected to Enabled Device VIN=5V TA=25C CL=68uF Iout 1 1A/div Iout 2 1A/div 2ms/div Channel 1 Short Circuit with Blanking Time and Recovery Vout 1 5V/div Vflag 1 5V/div 2ms/div Channel 2 Short Circuit with Blanking Time and Recovery Vout 2 5V/div Vflag 2 5V/div VIN=5V TA=25C CL=68uF VIN=5V TA=25C CL=68uF Iout 1 2A/div Iout 2 2A/div 20ms/div 20ms/div AP2186/AP2196 Rev 1 8 of 17 www.diodes.com APRIL 2009 (c) Diodes Incorporated AP2186/AP2196 1.5A DUAL CHANNEL CURRENT-LIMITED POWER SWITCH Typical Performance Characteristics Channel 1 Power On Vflag 1 5V/div (Continued) Channel 2 Power On Vflag 2 5V/div TA=25C CL=68uF Iout 1 500mA/div Ven 1 5V/div Vin 5V/div RL=3 Iout 2 500mA/div Ven 2 5V/div Vin 5V/div TA=25C CL=68uF RL=3 1ms/div Channel 1 UVLO Increasing 1ms/div Channel 1 UVLO Decreasing TA=25C CL=68uF Vin 2V/div RL=3 Vin 2V/div TA=25C Iout 1 500mA/div CL=68uF RL=3 Iout 1 500mA/div 1ms/div Channel 2 UVLO Increasing 10ms/div Channel 2 UVLO Decreasing TA=25C Vin 2V/div Vin 2V/div CL=68uF RL=3 Iout 500mA/div TA=25C CL=68uF RL=3 Iout 500mA/div 1ms/div 10ms/div AP2186/AP2196 Rev 1 9 of 17 www.diodes.com APRIL 2009 (c) Diodes Incorporated AP2186/AP2196 1.5A DUAL CHANNEL CURRENT-LIMITED POWER SWITCH Typical Performance Characteristics Channel 1 Enabled and Shorted with Channel 2 Disabled Vout 1 5V/div (Continued) Channel 1 Disabled and Channel 2 Enabled Ven1 5V/div Vout 1 5V/div Vout 2 5V/div Vflag 1 5V/div TA=25C CL=68uF Ven2 5V/div TA=25C CL=68uF Iout 2 500mA/div Vout 2 5V/div 100ms/div Turn-On Time vs Input Voltage 850 55 50ms/div Turn-Off Time vs Input Voltage 750 50 CL=1uF RL=10 TA=25C Turn-On Time (us) Turn-Off Time (us) 650 45 550 40 450 35 CL=1uF 350 RL=10 TA=25C 30 250 1.5 2 2.5 3 3.5 4 4.5 5 5.5 6 25 1.5 2 2.5 3 3.5 4 4.5 5 5.5 6 Input Voltage (V) Input Voltage (V) Rise Time vs Input Voltage 650 600 550 25 Fall Time vs Input Voltage 24 Rise Time (us) 500 450 400 350 300 2 2.5 3 3.5 4 4.5 5 5.5 6 Fall Time (us) 23 22 CL=1uF RL=10 TA=25C 21 CL=1uF RL=10 TA=25C 20 19 2 2.5 3 3.5 4 4.5 5 5.5 6 Input Voltage (V) Input Voltage (V) AP2186/AP2196 Rev 1 10 of 17 www.diodes.com APRIL 2009 (c) Diodes Incorporated AP2186/AP2196 1.5A DUAL CHANNEL CURRENT-LIMITED POWER SWITCH Typical Performance Characteristics Supply Current, Output Enabled vs Ambient Temperature 52 (Continued) Supply Current, Output Disabled vs Ambient Temperature 0.9 Supply Current, Output Disabled (uA) Supply Current, Output Enabled (uA) Vin=5.5V 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0.0 Vin=5.0V 47 Vin=5.0V Vin=5.5V 42 Vin=3.3V 37 Vin=2.7V 32 Vin=3.3V 27 -60 -40 -20 0 20 40 60 80 100 Vin=2.7V -60 -40 -20 0 20 40 60 80 100 Ambient Temperature (C) Ambient Temperature (C) Static Drain-Source On-State Resistance vs Ambient Temperature 2.60 Short-Circuit Output Current vs Ambient Temperature 180 Static Drain-Source On-State Resistance (m) 170 160 150 140 130 120 110 100 90 80 -60 -40 -20 Vin=2.7V Short-Circuit Output Current (A) 2.50 CL=100uF Vin=2.7V Vin=3.3V Vin=5.0V 2.40 Vin=3.3V 2.30 2.20 Vin=5V 2.10 Vin=5.5V 2.00 0 20 40 60 80 100 -60 -40 -20 0 20 40 60 80 100 Ambient Temperature (C) Ambient Temperature (C) Undervoltage Lockout vs Ambient Temperature 2.15 3.24 3.22 Threshold Trip Current vs Input Voltage Undervoltage Lockout (V) 2.10 UVLO Rising Threshold Trip Current (A) 3.20 3.18 3.16 3.14 3.12 3.10 2.05 2.00 TA=25C CL=68uF UVLO Falling 1.95 1.90 -60 -40 -20 0 20 40 60 80 100 3.08 2.8 3.3 3.8 4.3 4.8 5.3 Ambient Temperature (C) Input Voltage (V) AP2186/AP2196 Rev 1 11 of 17 www.diodes.com APRIL 2009 (c) Diodes Incorporated AP2186/AP2196 1.5A DUAL CHANNEL CURRENT-LIMITED POWER SWITCH Typical Performance Characteristics Current Limit Response vs Peak Current 45 40 (Continued) Current Limit Response (us) 35 30 25 20 15 10 5 0 0 2 4 6 8 10 12 VIN=5V TA=25C CL=68uF Peak Current (A) AP2186/AP2196 Rev 1 12 of 17 www.diodes.com APRIL 2009 (c) Diodes Incorporated AP2186/AP2196 1.5A DUAL CHANNEL CURRENT-LIMITED POWER SWITCH Application Note Power Supply Considerations A 0.01-F to 0.1-F X7R or X5R ceramic bypass capacitor between IN and GND, close to the device, is recommended. Placing a high-value electrolytic capacitor on the input (10-F minimum) and output pin(s) is recommended when the output load is heavy. This precaution reduces power-supply transients that may cause ringing on the input. Additionally, bypassing the output with a 0.01-F to 0.1-F ceramic capacitor improves the immunity of the device to short-circuit transients. Over-current and Short Circuit Protection An internal sensing FET is employed to check for over-current conditions. Unlike current-sense resistors, sense FETs do not increase the series resistance of the current path. When an overcurrent condition is detected, the device maintains a constant output current and reduces the output voltage accordingly. Complete shutdown occurs only if the fault stays long enough to activate thermal limiting. Three possible overload conditions can occur. In the first condition, the output has been shorted to GND before the device is enabled or before VIN has been applied. The AP2186/AP2196 senses the short circuit and immediately clamps output current to a certain safe level namely ILIMIT. In the second condition, an output short or an overload occurs while the device is enabled. At the instance the overload occurs, higher current may flow for a very short period of time before the current limit function can react. After the current limit function has tripped (reached the over-current trip threshold), the device switches into current limiting mode and the current is clamped at ILIMIT. In the third condition, the load has been gradually increased beyond the recommended operating current. The current is permitted to rise until the current-limit threshold (ITRIG) is reached or until the thermal limit of the device is exceeded. The AP2186/AP2196 is capable of delivering current up to the current-limit threshold without damaging the device. Once the threshold has been reached, the device switches into its current limiting mode and is set at ILIMIT. Note that when the output has been shorted to GND at extremely low temperature (< -30oC), a minimum 120-F electrolytic capacitor on the output pin is recommended. A correct capacitor type with capacitor voltage rating and temperature characteristics must be properly chosen so that capacitance value does not drop too low at the extremely low temperature operation. A recommended capacitor should have temperature characteristics of less than 10% variation of capacitance change when operated at extremely low temp. Our recommended aluminum electrolytic capacitor type is Panasonic FC series. FLG Response When an over-current or over-temperature shutdown condition is encountered, the FLG open-drain output goes active low after a nominal 7-ms deglitch timeout. The FLG output remains low until both over-current and over-temperature conditions are removed. Connecting a heavy capacitive load to the output of the device can cause a momentary over-current condition, which does not trigger the FLG due to the 7-ms deglitch timeout. The AP2186/AP2196 is designed to eliminate false over-current reporting without the need of external components to remove unwanted pulses. AP2186/AP2196 Rev 1 13 of 17 www.diodes.com APRIL 2009 (c) Diodes Incorporated AP2186/AP2196 1.5A DUAL CHANNEL CURRENT-LIMITED POWER SWITCH Application Note (Continued) Power Dissipation and Junction Temperature The low on-resistance of the internal MOSFET allows the small surface-mount packages to pass large current. Using the maximum operating ambient temperature (TA) and RDS(ON), the power dissipation can be calculated by: PD = RDS(ON)x I2 Finally, calculate the junction temperature: TJ = PD x RJA + TA Where: TA= Ambient temperature C RJA = Thermal resistance PD = Total power dissipation Thermal Protection Thermal protection prevents the IC from damage when heavy-overload or short-circuit faults are present for extended periods of time. The AP2186/AP2196 implements a thermal sensing to monitor the operating junction temperature of the power distribution switch. Once the die temperature rises to approximately 140C due to excessive power dissipation in an over-current or short-circuit condition the internal thermal sense circuitry turns the power switch off, thus preventing the power switch from damage. Hysteresis is built into the thermal sense circuit allowing the device to cool down approximately 25C before the switch turns back on. The switch continues to cycle in this manner until the load fault or input power is removed. The FLG open-drain output is asserted when an over-temperature shutdown or over-current occurs with 7-ms deglitch. Under-voltage Lockout (UVLO) Under-voltage lockout function (UVLO) keeps the internal power switch from being turned on until the power supply has reached at least 1.9V, even if the switch is enabled. Whenever the input voltage falls below approximately 1.9V, the power switch is quickly turned off. This facilitates the design of hot-insertion systems where it is not possible to turn off the power switch before input power is removed. Host/Self-Powered HUBs Hosts and self-powered hubs (SPH) have a local power supply that powers the embedded functions and the downstream ports (see Figure 2). This power supply must provide from 5.25V to 4.75V to the board side of the downstream connection under both full-load and no-load conditions. Hosts and SPHs are required to have current-limit protection and must report over-current conditions to the USB controller. Typical SPHs are desktop PCs, monitors, printers, and stand-alone hubs. Power Supply 3.3V 5V Downstream USB Ports AP2186 2 IN OUT1 7 0.1uF 68uF D+ DVBUS GND D+ DVBUS 0.1uF 68uF GND 0.1uF 8 FLG1 3 EN1 5 FLG2 4 EN2 USB Controller OUT2 GND 1 6 Figure 2. Typical Two-Port USB Host / Self-Powered Hub AP2186/AP2196 Rev 1 14 of 17 www.diodes.com APRIL 2009 (c) Diodes Incorporated AP2186/AP2196 1.5A DUAL CHANNEL CURRENT-LIMITED POWER SWITCH Application Note (Continued) Generic Hot-Plug Applications In many applications it may be necessary to remove modules or pc boards while the main unit is still operating. These are considered hot-plug applications. Such implementations require the control of current surges seen by the main power supply and the card being inserted. The most effective way to control these surges is to limit and slowly ramp the current and voltage being applied to the card, similar to the way in which a power supply normally turns on. Due to the controlled rise times and fall times of the AP2186/AP2196, these devices can be used to provide a softer start-up to devices being hot-plugged into a powered system. The UVLO feature of the AP2186/AP2196 also ensures that the switch is off after the card has been removed, and that the switch is off during the next insertion. By placing the AP2186/AP2196 between the VCC input and the rest of the circuitry, the input power reaches these devices first after insertion. The typical rise time of the switch is approximately 1ms, providing a slow voltage ramp at the output of the device. This implementation controls system surge current and provides a hot-plugging mechanism for any device. Marking Information (1) SOP-8L ( Top view ) 8 Logo Part Number 8 : Active Low 9 : Active High 7 6 5 6 : 2 Channel G : Green YY : Year : 08, 09,10~ WW : Week : 01~52; 52 represents 52 and 53 week X : Internal Code 4 AP21X X YY WW X X 1 2 3 (2) MSOP-8L-EP ( Top view ) 8 Logo Part Number 8 : Active Low 9 : Active High 1 7 6 5 A~Z : Green MSOP-8L-EP Y : Year : 0~9 W : Week : a~z : 1~26 week; A~Z : 27~52 week; Z represents 52 and 53 week 6 : 2 Channel YWXE AP21X X 2 3 4 AP2186/AP2196 Rev 1 15 of 17 www.diodes.com APRIL 2009 (c) Diodes Incorporated AP2186/AP2196 1.5A DUAL CHANNEL CURRENT-LIMITED POWER SWITCH Package Information (1) Package type: SOP-8L (All Dimensions in mm) 3.85/3.95 5.90/6.10 0.10/0.20 0.254 0.62/0.82 Gauge Plane Seating Plane Detail "A" 7~9 1.30/1.50 1.75max. 0.15/0.25 0.35max. 45 7~9 Detail "A" 0/8 1.27typ 4.85/4.95 0.3/0.5 8x-0.60 5.4 6x-1.27 8x-1.55 Land Pattern Recommendation (Unit: mm) (2) Package type: MSOP-8L-EP 8x-0.45 2.9/3.1 4.7/5.1 4.4 6x-0.65 1 0.75/0.95 1.10Max. 0.15Typ. 0.65Bsc. 0.22/0.38 8x-1.4 1 EXPOSED PAD (BOTTOM) Land Pattern Recommendation (Unit:mm) "A" 1 EXPOSED PAD (BOTTOM) 0.05/0.15 0.4/0.8 0.95Ref. DETAIL "A" 0.25 Gauge plane 0/8 0.05 2.9/3.1 1.65/1.95 1.35/1.65 AP2186/AP2196 Rev 1 16 of 17 www.diodes.com APRIL 2009 (c) Diodes Incorporated AP2186/AP2196 1.5A DUAL CHANNEL CURRENT-LIMITED POWER SWITCH IMPORTANT NOTICE DIODES INCORPORATED MAKES NO WARRANTY OF ANY KIND, EXPRESS OR IMPLIED, WITH REGARDS TO THIS DOCUMENT, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE (AND THEIR EQUIVALENTS UNDER THE LAWS OF ANY JURISDICTION). Diodes Incorporated and its subsidiaries reserve the right to make modifications, enhancements, improvements, corrections or other changes without further notice to this document and any product described herein. Diodes Incorporated does not assume any liability arising out of the application or use of this document or any product described herein; neither does Diodes Incorporated convey any license under its patent or trademark rights, nor the rights of others. Any Customer or user of this document or products described herein in such applications shall assume all risks of such use and will agree to hold Diodes Incorporated and all the companies whose products are represented on Diodes Incorporated website, harmless against all damages. Diodes Incorporated does not warrant or accept any liability whatsoever in respect of any products purchased through unauthorized sales channel. Should Customers purchase or use Diodes Incorporated products for any unintended or unauthorized application, Customers shall indemnify and hold Diodes Incorporated and its representatives harmless against all claims, damages, expenses, and attorney fees arising out of, directly or indirectly, any claim of personal injury or death associated with such unintended or unauthorized application. Products described herein may be covered by one or more United States, international or foreign patents pending. Product names and markings noted herein may also be covered by one or more United States, international or foreign trademarks. LIFE SUPPORT Diodes Incorporated products are specifically not authorized for use as critical components in life support devices or systems without the express written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: 1. are intended to implant into the body, or 2. support or sustain life and whose failure to perform when properly used in accordance with instructions for use provided in the labeling can be reasonably expected to result in significant injury to the user. B. A critical component is any component in a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or to affect its safety or effectiveness. Customers represent that they have all necessary expertise in the safety and regulatory ramifications of their life support devices or systems, and acknowledge and agree that they are solely responsible for all legal, regulatory and safety-related requirements concerning their products and any use of Diodes Incorporated products in such safety-critical, life support devices or systems, notwithstanding any devices- or systems-related information or support that may be provided by Diodes Incorporated. Further, Customers must fully indemnify Diodes Incorporated and its representatives against any damages arising out of the use of Diodes Incorporated products in such safety-critical, life support devices or systems. Copyright (c) 2009, Diodes Incorporated www.diodes.com AP2186/AP2196 Rev 1 17 of 17 www.diodes.com APRIL 2009 (c) Diodes Incorporated |
Price & Availability of AP2186MPG-13
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |