Power PCB Relay RX 1 pole (12 or 16 A) or 2 pole (8 A) DC or AC-coil * * * * * * Features 1 C/O or 1 N/O or 2 C/O contacts DC- or AC-coil 4 kV / 8 mm coil-contact Reinforced insulation (protection class II) Height 15.7 mm transparent cover optional Applications Domestic appliances, heating control, emergency lighting VZ Contact data Configuration Type of contact Rated current Rated voltage / max.breaking voltage AC Maximum breaking capacity AC Contact material 1 C/O or 1 N/O 12 A single contact Approvals in process 2 C/O 1pole 16 A 8A 250 Vac / 440 Vac 3000 VA 4000 VA 2000 VA AgNi 90/10 Coil data Nominal voltage Nominal coil power Operate category DC coil AC coil DC coil AC coil 5...110 Vdc 24...230 Vac 500 mW 0.75 VA 2 Coil versions, DC-coil Coil Nominal Pull-in Release Maximum Coil code voltage voltage voltage voltage resistance Vdc Vdc Vdc Vdc c 005 5 3.5 0.5 9.8 50+5% 006 6 4.2 0.6 11.8 68+5% 012 12 8.4 1.2 23.5 274+5% 024 24 16.8 2.4 47.0 1095+5% 048 48 33.6 4.8 94.1 4380+5% 060 60 42.0 6.0 117.6 6845+5% 110 110 77.0 11.0 215.6 23010+5% All figures are given for coil without preenergization, at ambient temperature +20C Other coil voltages on request Edition: 10/2003 Coil current mA 100.0 87.7 43.8 21.9 11.0 8.8 4.8 Rights to change data / design reserved Power PCB Relay RX 1 pole (12 or 16 A) or 2 pole (8 A) DC or AC-coil Coil versions, AC-coil Coil Nominal Pull-in Release Maximum Coil code voltage voltage voltage voltage resistance Vac Vac Vac Vac c 524 24 18.0 3.6 36.0 350+10% 615 115 86.3 17.3 172.5 8100+15% 730 230 172.5 34.5 345.0 32500+15% All figures are given for coil without preenergization, at ambient temperature +20C Coil current mA 31.6 6.6 3.2 Insulation Dielectric strength Clearance / creepage Insulation to IEC 60664 Voltage rating Pollution degree Overvoltage category Insulation dimensions coil-contacts contact-contact across open contacts Tracking resistance of relay base coil-contacts open contact circuit 4000 Vrms 1000 Vrms 8 / 8 mm 250 V 3 III reinforced insulation basic / functional insulation micro-disconnection CTI 250 Rights to change data / design reserved Edition: 10/2003 Flammability class according to UL 94 standard / transparent cover V-0 / HB Coil insulation system according to UL 1446 Class F Min. ambient temperature -40 C Max. ambient temperature / mounting distance 1pole 2pole DC-coil 85 C 1) / 2.5 mm 70 C / 2.5 mm AC-coil 70 C / 2.5 mm 70 C / 5 mm Mechanical life DC-coil >5x106 operations AC-coil >1x106 operations Max. switching rate at rated- / minimum load 6 min-1 / 600 min-1 Operate- / release time DC-coil typ. 7 / 2 ms Bounce time N/O contact/N/C contact typ. 1 / 3 ms Vibration resistance N/O 20 g, 10...150 Hz Shock resistance (destruction) 100 g Category of protection (IEC 61810) RT II - flux proof, RT III - wash tight 2) Relay weight 13 g Packaging unit 500 pcs. 1) version with transparent cover: 70C 2) version with transparent cover: RTII only Other data Power PCB Relay RX 1 pole (12 or 16 A) or 2 pole (8 A) DC or AC-coil Dimensions Dimensions in mm S0272-AA PCB layout / terminal assignment 1 pole 12 A 1 pole 16 A 2 pole 8 A S0418-BB S0418-BA S0418-BA S0163-BG S0163-BE S0163-BJ View on solder pins Dimensions in mm *) With the recommended PCB hole sizes a grid pattern from 2.5 mm to 2.54 mm can be used. S0163-BH S0163-BF Edition: 10/2003 Rights to change data / design reserved Power PCB Relay RX 1 pole (12 or 16 A) or 2 pole (8 A) DC or AC-coil Rights to change data / design reserved Edition: 10/2003 |
Price & Availability of RX124024C
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |