![]() |
|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
Specification Filter type : Parameter Issue: 01 QF1800 Front End ( Antenna) Crystal Filter min. 60 7,5 1 4 30 60 Date: 2003-03-10 typ. max. Unit 90 MHz kHz kHz dB dB kHz kHz kHz dB dB // pF // pF s mW mW C C C mm gram V Condition @ 3 dB @ fo 4,5 kHz ... dB / ... dB @ 20 dB @ 45 dB @ ... dB Frequency range Standard frequencies Pass bandwidth Pass band ripple Insertion / transducer attenuation Shape factor SF Selectivity Spurious response attenuation Ultimate attenuation Termination Input Output Group delay Input Power nominal Maximum (for 10 sec) Operating temperature range Operable temperature range Storage temperature range Enclosure (see drawing) Weight Packing ESD Sensitivity 45 50 50 // 0 50 // 0 0,1 1 0 +60 -20 +70 -40 +85 33,5 x 23,5 x 13 bulk 1500 HBM as in IEC 61000-42 Notes: 1. Terminology and test conditions are according to IEC standard IEC60368-1, unless otherwise stated Ordering Code: Model (Specification) QF1800 Frequency [MHz] 66,250 Products Buchfinkenweg 8 DE-74931 Lobbach Germany page 1(2) wwwAXTAL.com phone: +49 (6226) 9719689 fax: +49 (6226) 970133 E-mail: info@axtal.com Enclosure drawing Pin connections Terminal Symbol 1 IN 3 OUT 2,4 GND Function Input Output Ground, Case Environmental conditions Test Visual inspection, dimensions Sealing tests Solderability Resistance to soldering heat Shock Bump Free fall Vibration, sinusoidal Rapid change of temperature Dry heat Damp heat, cyclic Cold Climatic sequence Damp heat, steady state Endurance tests - ageing - extended aging IEC 60068 Part ... 2-17 2-20 2-27 2-29 2-32 2-6 2-14 2-2 2-30 2-1 1-7 2-3 IEC 61178-1 clause ... 4.5 4.6 4.8.2 4.8.3 4.8.8 4.8.6 4.8.9 4.8.7 4.8.5 4.8.11 4.8.12 4.8.13 4.8.14 4.8.15 4.9.1 4.9.2 Test conditions Enclosure styles as in IEC 60368-3, if applicable Gross leak: Test Qc, Fine leak: Test Qk Test Ta (235 5)C Method 1 Test Tb Method 1A, 5s Test Ea, 3 x per axes 100g, 6 ms half-sine pulse Test Eb, 4000 bumps per Axes, 40g, 6 ms Test Ed procedure 1, 2 drops from 1m height Test Fc, 30 min per axes, 10 Hz - 55 Hz 0,75mm; 55 Hz - 2 kHz, 10g Test Na, 10 cycles at extremes of operating temperature range Test Ba, 16 h at upper temperature indicated by climatic category Test Db variant 1 severity b), 55C/95% r.H., 6 cycles Test Aa, 2 h at lower temperature indicated by climatic category Sequence of 4.8.11, 4.8.12 st (1 cycle), 4.8.13, 4.8.12 (5 cycles) Test Ca, 56 days 30 days @ 85C 1000h, 2000h, 8000h @85C Products Buchfinkenweg 8 DE-74931 Lobbach Germany page 2(2) wwwAXTAL.com phone: +49 (6226) 9719689 fax: +49 (6226) 970133 E-mail: info@axtal.com |
Price & Availability of QF1800
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |