![]() |
|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
Preset counters electronic 2 presets, DIN rail housing Display LED, 6-digits, programmable NE230 Features - Preset counter with two presets - Display 6-digits - Mousing for control cabinet installation - Totalizer, hour counter - Operating mode, start count, scaling factor programmable - Connection: Incremental encoder or digital sensors - Preset mode programmable - Interface RS232 or RS422/RS485 NE230 - LED Preset counter Technical data - electrical ratings Voltage supply 14...28 VAC (50/60 Hz) 85...265 VAC (50/60 Hz) 10...30 VDC 5 VA, 4 W 18 VDC 15 % / 100 mA LED, 7-segment display 6-digits 7.6 mm Preset counter Main counter with 2 presets Totalizer Hour counter 0.0001...9999.99 Adding or subtracting A-B (difference counting) A+B total (parallel counting) Up/Down A 90 B phase evaluation 3 Hz, 25 Hz, 10 kHz programmable Step preset, Main preset, Parallel alignment, Trailing preset >10 years in EEPROM Button, electric or automatic Yes, electric (keylock) Normally open or closed, programmable 0.01...99.99 s RS232, RS422, RS485 Protection class II Overvoltage category II Pollution degree 2 DIN EN 61000-6-3 DIN EN 61000-6-2 1 www.baumerivo.com Weight approx. Approvals Technical data - electrical ratings Programmable parameters Operating modes Sensor logic Scaling factor Count mode Control inputs UL/cUL, CE conform Power consumption Sensor supply Display Number of digits Digit height Function Technical data - mechanical design Operating temperature Storing temperature Relative humidity E-connection 0...+50 C -20...+70 C 80 % non-condensing Plug-in screw terminals D-SUB-female connector, 9-pin (interface) IP 50 face DIN 0470-1 Membrane with softkeys Surface mount housing 70 x 89 x 58 mm 58 mm DIN rail housing EN 50022 Housing: GFV Polycarbonat Rear: PPO Keypad: Polyester 300 g Subject to modification in technic and design. Errors and omissions excepted. 30/10/2008 Scaling factor Count modes Core cross-section Protection DIN EN 60529 Operation / keypad Housing type Dimensions W x H x L Installation depth Mounting Materials 1.5 mm Counting frequency Operating modes Data memory Reset Keylock Outputs relay Output holding time Interfaces Standard DIN EN 61010-1 Emitted interference Interference immunity Preset counters electronic 2 presets, DIN rail housing Display LED, 6-digits, programmable NE230 Part number NE230. 1 AX01 Voltage supply 2 85...265 VAC 3 14...28 VAC / 10...30 VDC Outputs 1 Relay outputs Interface 0 Without interface 1 RS422 / RS485 2 RS232 Connection diagram 12 11 10 9 8 7 6 P2 5 4 3 2 1 Block circuit diagram Voltage supply + Signal input A B Control input 1 Reset Stop/Hold 2 9-pin SUB-D plug 1 2 Totalizer Main counter with 2 presets start count scaling factor 7 8 3 P1 4 5 P2 6 11 12 Operating time meter Interface RS485/RS422 RS232 Sensor supply + Output 9 10 A 90 B Trigger level Comparator inputs Supply voltage Input circuit PNP- / NPN- / AC-logic Programmable 0...2 VDC 3...40 VDC 3 k Output circuit 250 VAC / 110 VDC 1A 150 VA / 30 W 5 ms Inputs Input level Input level Low Input level High Input resistance Relay outputs Switching voltage max. Switching current max. Switching capacity max. Relay responding time Track B Track A 2 1 +18V 0V P1 Control input 1 2 3 Signal input 5 Sensor supply 1 max. 250 V terminal - terminal / - terminal 3 5 6 8 1 3 4 5 8 9 Shield Shield Shield GND TxD+ RxD+ RxD T,R+ RS232 RS485 RS422 70 65.8 D-SUB 9 29 48 58 2 www.baumerivo.com 30/10/2008 Subject to modification in technic and design. Errors and omissions excepted. Dimensions 24.7 35 41.8 RxD- TxD GND GND TxD- T,R- +5V 46 60 86 99 |
Price & Availability of NE230212AX01
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |