![]() |
|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
BEAM200 and BEAM200S Single-ended Reflected Type Beam Smoke Detectors The BEAM200 and BEAM200S single-ended reflected beam smoke detectors are uniquely suited for protecting open areas with high ceilings where other methods of smoke detection are difficult to install and maintain. Features *16 to 328 foot protection range *Single-ended, reflective design *Easiest alignment in the industry with digital display *6 field selectable sensitivity levels *Optional integral NFPA 72 sensitivity test feature *Removable plug-in terminal blocks *Built-in automatic gain control compensates for signal deterioration from dust build-up *Remote test station available *Paintable cover *Optional heater kits available The System Sensor BEAM200 and BEAM200S intelligent reflected beam smoke detectors are designed to be used with UL Listed compatible control panels only. Since all of the wiring is connected to one side, the installation of the single-ended reflective design is much easier than dual-ended projected beam detectors. Alignment is accomplished quickly via an optical sight and a 2 digit signal strength meter incorporated into the product. Listed for operation from -22F to 131F, the BEAM200 detector can be used in open area applications to provide early warning in environments where temperature extremes exceed the capability of other types of smoke detection. The BEAM200 smoke detector includes one wired transmitter/ receiver unit and one reflector. When smoke enters the area between the unit and the reflector it causes a reduction in the signal. The alarm is activated when the smoke level reaches the predetermined threshold. The BEAM200 device has four standard sensitivity selections along with two AcclimateTM settings. When either of the two Acclimate settings are selected, the detector automatically adjusts its sensitivity using advanced software algorithms to select the optimum sensitivity for the specific environment. The BEAM200S model is equipped with an added feature, an integral sensitivity test feature that uses a test filter attached to a Servo motor inside the detector optics. Using the remote test station RTS451, the motor is activated and moves the filter in the pathway of the light beam, thereby testing detector sensitivity. This integral sensitivity test feature allows the user to quickly and easily meet the annual maintenance and test requirements of NFPA 72. 7260-1209:229 53-04-E 2165 Agency Listings S911 3017888 BEAM200 and BEAM200S Specifications Operational Specifications Protection Range 16 ft to 328 ft (5 m to 100 m) Adjustment Angle 10 Degrees horizontal & vertical (The optics move independent of the unit) Sensitivity Levels Level 1 - 25% Level 2 - 30% Level 3 - 40% Level 4 - 50% AcclimateTM Level 1 - 30 to 50% Acclimate Level 2 - 40 to 50% Fault Condition (Trouble) 96% or more obscuration blockage Inalignmentmode Improperinitialalignment Self-compensation limit reached Alignment Aid Optical gunsight Integralsignalstrengthindication 2 digit display Alarm Indicator Local red LED and remote alarm Trouble Indicator Local yellow LED and remote trouble Normal Indicator Local flashing green LED Test/Reset Features IntegralSensitivityTestFilter(BEAM200Sonly, requires additional external power supply) Sensitivityfilter(Incrementalscaleonreflector) Local test switch Local reset switch Remotetestandresetswitch(Compatiblewith RTS451 and RTS451KEY test station) Smoke Detector Spacing On smooth ceilings, 30 to 60 feet between projected beams and not more than one-half that spacing between a projected beam and a sidewall. Other spacing may be used depending on ceiling height, airflow characteristics, and response requirements. See NFPA 72. Environmental Specifications Temperature Humidity Electrical Specifications Voltage Avg. Standby Current (24VDC) Avg. Current During Testing Alarm Current (24VDC) Fault Current (24VDC) Alignment Mode Current (24VDC) Mechanical Specifications Detector Dimensions -22Fto131F(-30Cto55C) 10 to 93% RH Noncondensing 15to32VDC 2 mA Max 500 mA Max 8.5 mA Max 4.5 mA Max 20 mA Max Electrical Specifications (BEAMHKR) Voltage 15 to 32 V Current 450 mA Max at 32 V (per reflector) Power Consumption 7.7 W at 24 V; 15 W at 32 V (per reflector) BEAM200(S) Parts OPTICAL GUNSIGHT ALIGNMENT SIGNAL STRENGTH METER HORIZONTAL OPTICS ALIGNMENT KNOB ALIGNMENT SENSITIVITY TEST VERTICAL OPTICS ALIGNMENT KNOB T3 T2 T1 RESET LISTED REMOTE POWER SOURCE * Only used for BEAM200S. See electrical ratings. + - +- +- + - - + FROM PANEL OR PREVIOUS DEVICE COMMUNICATION LINE 32 VDC MAX. TWISTED PAIR IS RECOMMENDED. TO NEXT DEVICE Activated Test Feature (BEAM200S only) SERVO MOTOR TEST FILTER + + Ordering Information Part No. BEAM200 BEAM200S Accessories BEAMLRK BEAMMMK + + Description Intelligentbeamsmokedetectorwith8reflector Intelligentbeamsmokedetectorwith8reflector and integral sensitivity test Long range accessory kit (3) additional reflectors (Required for applications in excess of 230 ft [70 m]) Multi-mount kit (Provides ceiling or wall mount capability with increased angular adjustment for either the beam or the reflector. When installed with the transmitter/receiver unit, BEAMSMK must be used as well) Surface mount kit for use with BEAMMMK Heavy duty multi-mount kit (for installations prone to vibration or where there is difficulty in maintaining the set angle. When installed with the transmitter/ receiver unit, 6500-SMK must be used as well) Surface mount kit for use with the 6500-MMK Heater kit for transmitter/receiver unit (See electrical requirements above) Heater kit for reflector (See electrical requirements above) Remote test station with key lock Remote test station used to initiate the NFPA sensitivity test function 10 in H x 7.5 in W x 3.3 in D (254 mm H x 191 mm W x 84 mm D) Reflector Dimensions (16 to 230) 7.9 in x 9.1 in (200 mm x 230 mm) Reflector Dimensions 15.7 in x 18.1 in (400 mm x 460 mm) (beyond 230) Electrical Specifications (BEAMHK) Voltage 15 to 32 V Current 92 mA at 32 V Power Consumption 1.6 W at 24 V; 3 W at 32 V BEAMSMK 6500-MMK 6500-SMK BEAMHK BEAMHKR RTS451KEY RTS451 3825OhioAvenue*St.Charles,IL60174 Phone:800-SENSOR2*Fax:630-377-6495 (c)2008 System Sensor. Product specifications subject to change without notice. Visit systemsensor.com for current product information, including the latest version of this data sheet. A05-0364-004*11/08*#2048 |
Price & Availability of BEAM200
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |