![]() |
|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
S/INT/XKA.....D/A/11/12/2000 Relais Statique/Montage sur rail DIN Solid State Relay for DIN rail fixation * Gamme pret a l'emploi: Relais montable sur rail DIN . * Pour tout type de charge. * Visualisation de commande par LED. * Sortie AC synchrone. * Ecreteur de surtension integre. * Haute immunite aux perturbations exterieures. * Connecteurs debrochables * New generation of SSR for DIN rail fixation. * For all king of load. * Control visualization by LED. * Zero-cross AC Output. * Integrated clamping voltage. * High immunity level. * Pluggable connectors 54 0,4 49,7 page 1 / 2 F/GB XKA.....D AC, AC-DC control 4A/ 230VAC output Application typique/Typical application Ph 1~ 3 celduc France output 230Vac 4A 1 230VAC max 275VAC SKA 20420 4A AC/DC 76,4 0,4 1~ 2 10133 celduc France 3+ input 4-30Vdc XKA 20420D input 6-30VDC 2~ 4 2~ Charge / Load 4 - - + 28 59 0,4 12,2 0,2 N Types / Models Modeles / References Caracteristiques d'entree / Input characteristics (20C) Plage de tension de commande (Uc) / Input voltage range (Uc) Tension maximum de commande / Maximum control voltage Tension minimum de commande / Minimum control voltage Courant de fonctionnement/Operating current Courant maximum de commande / Maximum control current Tension de relachement/Release voltage Resistance interne / Input internal resistor AC OUTPUT XKA 20420D autre nous consulter other consult us Unit VAC/DC VDC VDC mADC mADC VDC DC input 6-30 30 6 3 30 0,8 1000 Caracteristiques generales /General characteristics Temperature de stockage / Storage temperature Temperature de fonctionnement /Operating temperature Tension d'isolement entree-sortie / Input-output isolation voltage Capacite entree-sortie/ Input-output capacity Poids/Weight Largeur / Width (fig. ) - 40 a/to +150 -40 a/to +80 4000 3 30 12,2 Unit C C VRMS pF g mm Proud to serve you All technical caracteristics are subject to change without previous notice. Caracteristiques sujettes a modifications sans preavis. r celduc e l a i s S/INT/XKA.....D/A/11/12/2000 page 2 / 2 F/GB Types / Models Modeles / References Caracteristiques de sortie/Output characteristics(20C) Types / Models Tension nominale / Nominal voltage Plage tension de fonctionnement / Operating range Tension crete (ecreteur de tension) / Peak voltage (clamping voltage) Niveau de synchonisation / Synchronizing level Courant nominal (voir les caracteristiques thermiques) / Nominal current (see thermal curves) Courant de surcharge accidentel admissible maximum (10ms) : / Maximum accidental overload current (10ms) : ITSM Chute tension directe (In) / On state voltage drop (IN) Courant de fuite etat bloque (@Un/50Hz) / Off state leakage current (@Un/50Hz) Courant de charge minimum / Minimum load current Courant de maintien / Holding current Temps de fermeture (50Hz) / Turn on time (50Hz) Temps d'ouverture (50Hz) / Turn off time (50Hz) Frequence d'utilisation / Operating frequency dv/dt etat bloque / Off state dv/dt I2t (<10ms) di/dt non repetitif / No repetitive di/dt Homologation / Approval AC OUTPUT XKA 20420D AC output Synchrone Zero cross autre nous consulter other consult us Unit 230 12 a/to 275 600 (450 @1mA) 12 4 100 1,6 0,3 5 50 10 10 10 a/to 440 500 50 20 Tous les elements sont UL/All components are UL Fig. 3 : Courant de surcharge non repetitif / Non repetitive surge current VRMS VRMS VPEAK V ARMS APEAK VPEAK mARMS mARMS mA ms ms Hz V/s A2s A/s Fig.2 Caracteristiques thermiques / thermal curves : 6 5 Courant commute (A eff) / Switched current (A RMS) 4 3 2 1 0 0 10 20 30 40 50 60 70 80 90 Temperature ambiante (C) / Ambient temperature (C) 100 Itsm (Apeak) Uc Uc min x Ucmin/max:Voir plage de tension de commande / See input voltage range 90 80 70 60 50 40 30 20 10 0 1 10 100 Nombres de cycles / Number of cycles ma XKA 1000 Precautions : * Les relais a semiconducteurs ne procurent pas d'isolation galvanique entre le reseau et la charge. * Dans le cas de plusieurs modules cote a cote, prevoir un derating en courant. Cautions : * Semiconductor relays don't provide any galvanic insulation between the load and the mains. * In case of many SSRs side by side, take a derating current in to account. celduc r e l a i s www.celduc.com Rue Ampere B.P. 4 42290 SORBIERS - FRANCE E-Mail : celduc-relais@celduc.com Fax +33 (0) 4 77 53 85 51 Service Commercial France Tel. : +33 (0) 4 77 53 90 20 Sales Dept.For Europe Tel. : +33 (0) 4 77 53 90 21 Sales Dept. Asia : Tel. +33 (0) 4 77 53 90 19 |
Price & Availability of XKA20420D
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |