![]() |
|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
Process displays electronic Analogue inputs and outputs for measured values Large 14 mm display LED, 6-digits, programmable PCD45 Features - Process display - Display 6-digits - Connection: Two one-channel analogue sensors - Two limits - Ratio display - Three analgue outputs - Programmable peak value memory (slave pointer) - Interface RS232 or RS422/RS485 PCD45 - Process display Technical data - electrical ratings Voltage supply Power consumption Sensor supply Display Number of digits Digit height Function 85...265 VAC (50/60 Hz) 18...30 VDC 7 VA, 5 W 18 VDC 10 % / 350 mA LED, 7-segment display 6-digits 14 mm Digital display of 2 analogue measured values Peak value memory (slave pointer) Analogue resolution 12 bit PNP 3 outputs Hold, Reset, Keylock, etc. >10 years in EEPROM 0(2)...10 V, 0(4)...20 mA Resolution 12 bit Temp. coeffic. typ. 20 ppm/C 3 analogue outputs 0...+10 V, -10...+10 V Resolution 12 bit Temp. coeffic. typ. 20 ppm/C Potential-free change-over contact RS232, RS422, RS485 Protection class II Overvoltage category II Pollution degree 2 DIN EN 61000-6-3 DIN EN 61000-6-2 Technical data - mechanical design Operating temperature Storing temperature Relative humidity Core cross-section Protection DIN EN 60529 Operation / keypad Housing type Dimensions W x H x L Cutout dimensions Installation depth Mounting Weight approx. Material 0...+50 C -20...+70 C 80 % non-condensing 1.5 mm IP 65 face with seal Membrane with softkeys Housing for control panel installation 96 x 48 x 124 mm 96 x 45 mm (+0.6) 123.75 mm Front panel installation by clip frame 350 g (AC), 250 g (DC) Housing: Makrolon 6485 (PC) Approvals Description Two analog inputs for connection of two sensors. This information can be indicated by F1 and F2. Both measured values F1 and F2 are calculated internally and output by F3. The measured values F1, F2 and F3 can be output as separate analogue signals -10...+10 V / 0...+10 V for process control. Two limits P1" and P2" that may be assigned at will enable monitoring of production processes. Technical data - electrical ratings Programmable parameters Analogue inputs and outputs 2 limits Control inputs Calculating functions Offset (maximum and minimum analogue limit) UL/cUL, CE conform Subject to modification in technic and design. Errors and omissions excepted. 30/10/2008 Measuring principle Input logic Control inputs Control functions Data memory Analogue input Analogue output Outputs relay Interfaces Standard DIN EN 61010-1 Emitted interference Interference immunity 1 www.baumerivo.com Analogue inputs and outputs for measured values Large 14 mm display LED, 6-digits, programmable Process displays electronic PCD45 Connection diagram 15 14 13 12 11 10 9 3 2 1 + F2 Control input Analog input + F1 Sensor supply 8 7 6 5 4 3 2 1 Supply voltage Block circuit diagram Voltage supply + Analog input F1 + F1 - F2 + 1 2 7 8 Sensor supply + Analog output 10 9 12 11 Measuring value F3 Control input 1 2 3 Calculation functions 13 14 15 Ratio F1 : F2 Difference F1 - F2 Stretching Shrinking Adding F1 + F2 3 Measuring value F1 / F2 / F3 RS485 T,R+ T,RRS422 TxD+ 16 TxD- 17 RxD+ 18 RxD- 19 TxD 16 RxD 18 GND 19 Interface RS232 Interface RS485/RS422 Limit P1 Limit P2 4 5 P2 6 Measuring value F2 Measuring value F1 25 10V 26 0V A2 A1 - +V 0V P2 P1 Limit value max. 250 V terminal - terminal / - terminal 19 18 17 16 RxD+ TxD+ RxDTxD- 27 10V 28 0V 30 29 28 27 26 25 F2 - 10V 10V 10V 0V 0V 0V 29 10V 30 0V A3 GND RxD Analog output RS232 T,R+ T,R- TxD A3 A2 A1 RS422 Output P1 RS485 Trigger level Comparator inputs Inputs Input level Input level Low Input level High Input resistance Relay outputs Switching voltage max. Switching current max. Switching capacity max. Relay responding time Input circuit PNP-logic Programmable 3...40 VDC 3 k Output circuit 250 VAC / 110 VDC 1A 150 VA / 30 W 5 ms Subject to modification in technic and design. Errors and omissions excepted. 30/10/2008 0...2 VDC 2 www.baumerivo.com Process displays electronic Analogue inputs and outputs for measured values Large 14 mm display LED, 6-digits, programmable PCD45 Part number PCD45. PX01 Voltage supply 2 85...265 VAC 3 18...30 VDC 0 1 2 3 Inputs / outputs 0...10 V input / -10...+10 V output 0...20 mA input / -10...+10 V output 0...10 V input / 0...+10 V output 0...20 mA input / 0...+10 V output Interface 0 Without interface 1 RS422 / RS485 2 RS232 Dimensions 96 123.75 7 48 109 19.75 1-10 3 www.baumerivo.com 30/10/2008 Subject to modification in technic and design. Errors and omissions excepted. Analogue inputs and outputs for measured values Large 14 mm display LED, 6-digits, programmable Process displays electronic PCD45 4 www.baumerivo.com 30/10/2008 Subject to modification in technic and design. Errors and omissions excepted. |
Price & Availability of PCD45102PX01
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |