Issue: 01 Date: 2005-12-08 Specification AXHV6007 Oscillator type : VCO - Voltage Controlled Oscillator in TO-8 package Parameter min. typ. max. Unit Condition 10600 12300 MHz @ 25C Frequency tuning range Frequency adjustment range EFC voltage VC 0 20 V 40 166 MHz/V Tuning sensitivity (f / VC) EFC slope positive RF output Signal waveform SINUS Amplitude +5.2 +11 dBm RL = 50 Harmonics -15 dBc -85 dBc/Hz @ 100 kHz Phase Noise Supply voltage VS 4.75 5 5.25 V Current consumption (steady state) 100 mA -40 +85 C Operating temperature range -45 +90 C Operable temperature range -55 +95 C Storage temperature range 12.7 O x 5.5 mm "TO-8" Enclosure (see drawing) DiameterxH 5 gram Weight bulk IEC 60286-3 Packing 1500 V HBM, IEC 61000-4-2 ESD Sensitivity Notes: 1. Terminology and test conditions are according to IEC standard IEC60679-1, unless otherwise stated Ordering Code: Model (Specification) AXHV6007 Frequency Range [MHz] 10600-12300 GmbH & Co. KG Wasemweg 5 D-74821 Mosbach Germany AXHV6007 page 1(4) www.axtal.com fon: +49 (6261) 939834 fax: +49 (6261) 939836 E-mail: info@axtal.com Enclosure drawing Pin connections Pin # 1 2 3 4 Symbol RF OUT VS VC GND Function RF Output Supply Voltage (Bias) Control Voltage (EFC) Ground bottom view Typical Performance f/GHz 12,5 HV6007 12 11,5 11 10,5 0 5 10 Vtune/V 15 20 GmbH & Co. KG Wasemweg 5 D-74821 Mosbach Germany AXHV6007 page 2(4) www.axtal.com fon: +49 (6261) 939834 fax: +49 (6261) 939836 E-mail: info@axtal.com Sensitivity(MHz/V) 200 HV6007 150 100 50 0 0 5 10 Vtune/V 15 20 Pout/dBm 15 HV6007 10 5 0 0 5 10 Vtune/V 15 20 GmbH & Co. KG Wasemweg 5 D-74821 Mosbach Germany AXHV6007 page 3(4) www.axtal.com fon: +49 (6261) 939834 fax: +49 (6261) 939836 E-mail: info@axtal.com Environmental conditions Test Visual inspection, dimensions Sealing tests (if applicable) Solderability Resistance to soldering heat Shock* Bump* Free fall* IEC 60068 Part ... IEC 60679-1 clause ... 4.3 4.6.2 4.6.3 Test conditions Enclosure styles as in IEC 60679-3 or 61837, if applicable Gross leak: Test Qc, Fine leak: Test Qk Test Ta (235 5)C Method 1 Test Tb Method 1A, 5s Test Ea, 3 x per axes 100g, 6 ms half-sine pulse Test Eb, 4000 bumps per Axes, 40g, 6 ms Test Ed procedure 1, 2 drops from 1m height Test Fc, 30 min per axes, 10 Hz - 55 Hz 0,75mm; 55 Hz - 2 kHz, 10g Test Na, 10 cycles at extremes of operating temperature range Test Ba, 16 h at upper temperature indicated by climatic category Test Db variant 1 severity b), 55C/95% r.H., 6 cycles Test Aa, 2 h at lower temperature indicated by climatic category Sequence of 4.6.14, 4.6.15 (1st cycle), 4.6.16, 4.6.15 (5 cycles) Test Ca, 56 days 2-17 2-20 2-58 2-27 2-29 2-32 4.6.8 4.6.6 4.6.9 4.6.7 Vibration, sinusoidal* 2-6 Rapid change of temperature Dry heat Damp heat, cyclic* Cold Climatic sequence* Damp heat, steady state* Endurance tests - ageing - extended aging 2-14 2-2 2-30 2-1 1-7 2-3 4.6.5 4.6.14 4.6.15 4.6.16 4.6.17 4.6.18 4.7.1 4.7.2 30 days @ 85C, OCXO @25C 1000h, 2000h, 8000h @85C GmbH & Co. KG Wasemweg 5 D-74821 Mosbach Germany AXHV6007 page 4(4) www.axtal.com fon: +49 (6261) 939834 fax: +49 (6261) 939836 E-mail: info@axtal.com |
Price & Availability of AXHV6007 |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |