 XCS
Controller
Description
The Power-One XscendTM Controller System (XCS) provides comprehensive monitoring and control for Power-One's Xscend DC power systems. This digital controller monitors total system conditions including DC voltage, rectifier current, rectifier temperature, system capacity, battery parameters and circuit breaker status. The XCS enables data storage of system configuration information such as battery type, installation date and system commission date. Visual notification of alarm and warning conditions are indicated by front panel LEDs, while descriptions of the alarms are provided through an LCD, or as an option, may be accessed remotely through a modem or a Network Interface (PNI) module. To meet individual site requirements, the XCS contains a logic operator that can be programmed to monitor and control specified requirements. This allows actions to be set, alarms to be triggered, and outputs to be activated based on internal and external signal monitoring, comparing and processing.
Features
User controls and interfaces: Intelligent battery management:
* Simple menu-guided operation using front
panel mounted pushbuttons and an LCD
* Temperature compensation with
programmable compensation factor
* User-selectable alarm parameters * 40 event data logging * Password controlled environment * Multiple language options * RS232 Interface and Form "C" dry
alarm contacts
* Automatic and manual load testing * Battery voltage and symmetry monitoring * Capacity testing * Low voltage disconnect * Monthly data logging
www.power-one.com
XCS
Controller
Input
Voltage Current 18-72V DC <200 mA at 48V, <400 mA at 24V Weight 4.94kg (11lbs.) -40 to +65C -50 to +85C Storage: Transport: Operation: ETS 300 019-2-1 ETS 300 019-2-2 ETS 300 019-2-3
Other Technical Data
Dimensions (WxHxD) 483/584 x 44 x 274mm (19/23 x 1.75 x 10.8in.)
Interface
Display Internal Communication Internal Communication 2x20 character LCD with backlight RS485 Data Bus for communication with a maximum of 128 rectifiers and 128 sub-controllers RS232 Serial interface for remote control from a PC with PowCom software
Green LED Yellow LED Red LED Power ON System warning message System failure message
Operating Temperature Storage Temperature
Environment
Indications Controls Signal Collection Software Language
Battery
Battery Disconnection An optional feature that allows voltage controlled disconnection of batteries. Manual time controlled or automatic boost charging with adjustable time and voltage levels. Automatic or manual testing of batteries up to four times per year with a 10 test memory. Variables include: test duration, end voltage, and amount of Ah's to be discharged during test. Optional tool that measures batteries for early detection of thermal runaway. Allows for separate measurements of up to 12 parallel battery branches, each divided into four blocks. Allows continuous adjustment of output voltage according to battery temperature. Features include adjustable compensation factor and separate thresholds for high temperature alarms. Optional feature that allows voltage or time controlled disconnection of non-essential load. Monthly logging of essential battery parameters, including temperature, temp. hours, current, charging voltage, and symmetry voltage. Parameters are stored for 5 years.
Four pushbutton controls Wide range of interface units with analog and digital input/outputs Site upgradeable by EEPROM flash Multiple language options
Boost Charging
Battery Test
Alarms
Alarm History Alarm Contacts Alarms The last 40 events are saved and include a time and date stamp. 6 potential free change-over alarm contacts. Two open collector outputs for LVD operation. High System Voltage Low System Voltage Load/ Battery Disc. Mains Error Distribution Fuse Failure Battery Failure Module Failure Battery Temp. Alarm Symmetry Fault Battery Fuse Failure High Load Battery Fuse Disc. Urgent Module Failure Communication Failure Partial Load Disc. 1* 2* 4* 3* 4* 6* 5* 6* 6* 4* 5* 5* 4* 5* 4* Symmetry Measurement
Temperature Compensation Charging
PLD
* All alarms are indicated using an LED and displayed in the LCD. The numbers represent an example of alarm routing. Sixteen additional alarms are available and are configurable by changing the PCS EEPROM.
Enhanced Battery Monitoring
Note: All specifications are subject to change without notification.
11V0005-061 XCS V3.0
www.power-one.com


▲Up To Search▲   

 
Price & Availability of XCS

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X