Part Number Hot Search : 
GBU12J DT74ALV KBPC50 4HC25 DG202D 2SJ50 4R3ML S911201
Product Description
Full Text Search
 

To Download SPLPL900 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 Impuls-Laserdiode im Plastikgehause 4 W Spitzenleistung Pulsed Laser Diode in Plastic Package 4 W Peak Power Lead (Pb) Free Product - RoHS Compliant SPL PL90_0
Besondere Merkmale * Kostengunstiges Plastikgehause * Zuverlassiges InGaAs/GaAs kompressiv verspanntes Halbleiter-Material * Hochleistungslaser mit Large-Optical-Cavity" (LOC) Struktur fur ein schmales Fernfeld * Laterale Austrittsoffnung 60 m Anwendungen * * * * Entfernungsmessung Sicherheit, Uberwachung Beleuchtung, Zundung Test- und Messsysteme
Features * Low cost plastic package * Reliable strained InGaAs/GaAs material * High power large-optical-cavity (LOC) structure for a narrow far-field * Lateral laser aperture 60 m
Applications * * * * Range finding Security, surveillance Illumination, ignition Test and measurement systems
Sicherheitshinweise Je nach Betriebsart emittieren diese Bauteile hochkonzentrierte, nicht sichtbare InfrarotStrahlung, die gefahrlich fur das menschliche Auge sein kann. Produkte, die diese Bauteile enthalten, mussen gema den Sicherheitsrichtlinien der IEC-Norm 60825-1 behandelt werden. Typ Type SPL PL90_0
Safety Advices Depending on the mode of operation, these devices emit highly concentrated non visible infrared light which can be hazardous to the human eye. Products which incorporate these devices have to follow the safety precautions given in IEC 60825-1 "Safety of laser products".
Opt. Spitzenausgangsleistung Opt. Peak Power 4W
Wellenlange Wavelength 905 nm
Bestellnummer Ordering Code Q62702OP5270
2007-04-16
1
SPL PL90_0
Grenzwerte (TA = 25 C) Maximum Ratings Parameter Parameter Spitzenausgangsleistung Peak output power Durchlastrom Forward current Pulsbreite (Halbwertsbreite) Pulse width (FWHM) Tastverhaltnis Duty cycle Sperrspannung Reverse voltage Betriebstemperatur Operating temperature Lagertemperatur Storage temperature Lottemperatur (tmax = 10 s, 2 mm von Gehauseunterseite) Soldering temperature (tmax = 10 s, 2 mm from bottom edge of case) Symbol Symbol min. Werte Values max. 5 6 100 0.1 3 + 85 + 100 + 260 W A ns % V C C C - - - - - - 40 - 40 - Einheit Unit
Ppeak IF tp
d.c.
VR Top Tstg Ts
2007-04-16
2
SPL PL90_0
Optische Kennwerte (TA = 25 C) Optical Characteristics Parameter Parameter Zentrale Emissionswellenlange1) Emission wavelength1) Spektrale Breite (Halbwertsbreite)1) Spectral width (FWHM)1) Spitzenausgangsleistung1) Peak output power1) Schwellstrom Threshold current Betriebsspannung1) Operating voltage1) Minimale Anstiegs- und Abfallzeit (10% ... 90%) Minimum rise and fall time (10% ... 90%) Austrittsoffnung Aperture size Strahldivergenz (Halbwertsbreite) Beam divergence (FWHM) Temperaturkoeffizient der Wellenlange2) Temperature coefficient of wavelength2) Temperaturkoeffizient der opt. Ausgangsleistung Temperature coefficient of optical power Thermischer Widerstand Thermal resistance
1)
Symbol Symbol min. peak 895 - 3 0.15 2.7 -
Werte Values typ. 905 3 4 0.3 3.4 1 max. 915 - 5 0.5 4 -
Einheit Unit nm nm W A V ns
Pop Ith Vop tr , tr
wxh
|| x / T Pop/PopT - - -
60 x 2 11 x 25 - 0.28 -0.4 - -
m2 Grad deg. nm/K %/K
Rth JA
-
160
-
K/W
Standardbetriebsbedingungen beziehen sich auf eine Pulsbreite von 100 ns bei einer Pulswiederholrate von 1 kHz und einem Betriebsstrom von 5 A bei TA = 25 C. Standard operating conditions refer to pulses of 100 ns width at 1 kHz repetition rate with 5 A operating current at TA = 25 C.
2007-04-16
3
SPL PL90_0
Optical output power Popt and forward voltage VF vs. forward current IF (TA = 25 C)
VF
5 V 4
OHL00748
Optical spectrum, relative intensity Irel vs. Wavelength (TA = 25 C, Popt = 0.3 W)
1.00
OHF00565
10 WP opt 8
Irel
0.75
3
6
0.50
2
4
1
2
0.25
0
0
1
2
3
4
5
6
7A 8
0
0
880
890
900
910 nm 920
IF
Far-field distribution parallel to junction Irel vs. (TA = 25 C, Popt = 0.3 W)
1.00
OHL00749
Far-field distribution perpendicular to junction Irel vs. (TA = 25 C, Popt = 0.3 W)
1.00
OHL00753
Irel
0.75
Irel
0.75
0.50
0.50
0.25
0.25
0 -30
-20
-10
0
10
Deg 30
0 -40 -30 -20 -10 0
10 20 Deg 40
2007-04-16
4
SPL PL90_0
Mazeichnung Package Outlines
Chip position Cathode Area not flat
0.6 (0.024) 0.4 (0.016) 0.8 (0.031) 0.4 (0.016)
2.54 (0.100) mm spacing
X
Bottom view 5.9 (0.232) 5.5 (0.217) Y
1.8 (0.071) 1.2 (0.047) 29.0 (1.142) 27.0 (1.063)
5.0 (0.197) 4.2 (0.165)
0.6 (0.024) 0.4 (0.016)
Detail X
0.1 (0.004) ... 0.7 (0.028)
Detail Y
5.1 (0.201)
Chip position
o0.3 A A
GEOY6066
5
5 3.5 (0.138) 3.7 (0.146)
Mae in mm (inch) / Dimensions in mm (inch).
2007-04-16
5
1.7 (0.067) 1.9 (0.075)
4.8 (0.189)
SPL PL90_0
Published by OSRAM Opto Semiconductors GmbH Wernerwerkstrasse 2, D-93049 Regensburg www.osram-os.com (c) All Rights Reserved. The information describes the type of component and shall not be considered as assured characteristics. Terms of delivery and rights to change design reserved. Due to technical requirements components may contain dangerous substances. For information on the types in question please contact our Sales Organization. Packing Please use the recycling operators known to you. We can also help you - get in touch with your nearest sales office. By agreement we will take packing material back, if it is sorted. You must bear the costs of transport. For packing material that is returned to us unsorted or which we are not obliged to accept, we shall have to invoice you for any costs incurred. Components used in life-support devices or systems must be expressly authorized for such purpose! Critical components 1 , may only be used in life-support devices or systems 2 with the express written approval of OSRAM OS. 1 A critical component is a component usedin a life-support device or system whose failure can reasonably be expected to cause the failure of that life-support device or system, or to affect its safety or effectiveness of that device or system. 2 Life support devices or systems are intended (a) to be implanted in the human body, or (b) to support and/or maintain and sustain human life. If they fail, it is reasonable to assume that the health of the user may be endangered.
2007-04-16
6


▲Up To Search▲   

 
Price & Availability of SPLPL900

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X