If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
PPS 25 Power System Cabinet System Description PPS 25 modular DC power cabinet systems are designed to meet rigid telecom applications with very high reliability and flexibility for future expansion. These cabinet power solutions provide rectification, system management and power distribution while allowing configurable solutions within the same cabinet or through the use of external distribution cabinets. The PPS 25 systems are based on hot-swappable fan-cooled PMP 25 rectifier modules with constant output power available at 24V/110A or 48V/50A per module. System management is accomplished through messages and alarms displayed on the system controller's (PCS) LCD screen and can also be displayed remotely via the PC-based PowCom software package. TM Features * * * * * * * * * * * * High reliability Simple installation and operation LCD display for self-guided controller operation Interfaces standards include RS232, and Form "C" dry alarm contacts with grouped alarms Up to 1200A per cabinet Live expansion up to 6400A Plug-in ready for various DC distributions and subracks Inter-cabinet DC paralleling bus Site programmable supervision unit Intelligent battery management Optional Ethernet (SNMP compatible) interface module International standards compliance www.power-one.com System Configurations PPS 25 with integrated DC distribution PPS 25 with bulk outputs feeding remote DC distributions PPS 25 System The PPS 25 system offers flexible solutions that fit a large number of site requirements. Some of these features include: * Easy configuration with internal or remote DC distribution * Internal DC bus for simple plug-in of load distribution modules, battery breaker modules, and rectifier subracks * Inter-cabinet paralleling bus for live connection of expansion cabinets * Internal data bus for advanced system monitoring and control * Wide range of plug-in DC load distributions, low and high ohmic PPS 25 Power System Cabinet System System Components Rectifier Modules The PPS 25 system utilizes plug-in rectifier modules that are based on a soft-switching approach. Features include 3 LEDs for rectifier status indication, thermal shutdown, and input overvoltage disconnection with an automatic reset. Model PMP 25.24 SIC PMP 25.48 SIC Voltage 24V DC 48V DC Power (max.) 3080W 2800W Current (max.) 110A at 28V DC 50A at 56V DC PMP 25 Rectifier Supervision Module Advanced system supervision is accomplished using a microprocessor based control module that allows both local and remote system monitoring. PCS Features * * * * * * * * * * Menu guided operation RS232 interface for remote operation Enhanced battery management and testing Temperature compensation Site programmable flash EPROM Supervision for up to 128 rectifiers and 128 micro processors Multiple language choices Programmable alarms, logic functions, and operations Monthly data logging Optional Ethernet interface through SNMP and/or TCP/IP PCS Supervision Module 100mm Cable Duct Battery Breaker Modules Plugable battery breaker module, based on MCCB's, MCB's or knife fuses Cabinet Innovative and flexible cabinet design. Cabinet Features * In cabinet vertical DC bus allows live expansion of distribution and rectifier modules * * * * Separate cable duct for output load cables Inter cabinet DC bus for live cabinet expansion Top or bottom cable entry Matching DC distribution cabinets PPS 25 Cabinet DC Distribution Plugable load distribution module, based on MCB's, MCCB's or knife fuses. Low or high ohmic. PPS 25 Power System Cabinet System Input Model Input Inputs (max.) PPS 25 System 230/400V 3-phase (site configurable) Single input for each 6 rectifier positions (4 inputs for 24 rectifier cabinets) Output Rectifier Modules (max.) 24 (bulk output feed to battery and load) Several battery breaker modules are available and are based on: MCCB's: 1x1500A, 2x600A, 4x384A MCB's: 12x100A Knife fuses: 5xNH1-3 Several battery breaker modules are available and are based on: MCCB's: 1x1500A, 2x600A, 2x384A, 4x384A MCB's: 24x2-63A, 16x80-100A, 24x2-16A high ohmic Knife fuses: 5xNH1-3, 9xNH00 Yes (max. 1200A per cabinet) Yes Battery Outputs Load Outs - MCB (2-63A) 24V DC Version 48V DC Version Features Supervision PCS Expansion Expansion Rack Expansion Cabinet Up to six subracks per cabinet, each with four rectifier modules Expansion cabinet can be be placed to the left or right of existing cabinets, allowing up to 128 rectifier modules Battery Battery Symmetry Inputs Low Voltage Battery Disconnection (LVBD) 4 (expandable to 12 by adding the optional interface circuit board) Yes (through a trip coil in each MCCB or contactor) Mechanical Dimensions (WxHxD) Cable Entry Plug-in for multiple racks, subracks, and PDU's 600x2150x600mm Top and/or bottom for cables <50sq/mm (using cable duct) Top or bottom entry for cables >50sq/mm A total of 35U is available for rectifier subracks, distribution, and battery breaker modules (29U at bottom cable entry) Options Temp. Comp. Charge Partial Load Disconnect Hinged Door Access Ethernet Network Interface Modem Interface Yes Yes Yes Yes Yes Note: All specifications are subject to change without notification. 11V0005-039 PPS25 SY V3.0 www.power-one.com |
Price & Availability of PPS2524 |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |