![]() |
|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
VER : A_0 update : 94.03.21 AC-DC Power Module 1 5 WaANCl tSERIES t t U r a m i niature Modular Switching Power Supplies KEY FEATURES Switching Power Module for PCB Mountable Fully Encapsulated Plastic Case Universal Input Range 90-264VAC, 47-440 Hz Regulated Output Low Ripple and Noise High Efficiency CE, cUL, TUV Approvals 2-Year Product Warranty ANC 15 s Wattse r i e s ELECTRICAL SPECIFICATIONS Model No. ( Single Output ) ANC-5S 15W 47-440 Hz 280 mA max. (115 VAC) / 170 mA max. (230 VAC) 10 A max. (115 VAC) /20 A max. (230 VAC) 0.75 mA max. 1.5 A slow blow type 5V 2% 3000 0.5% 0.5% 0% 470-23,000F depending on model <0.2% Vout +40mV max (Vp-p) <0.5% Vout +50mV max (Vp-p) 70% 15 ms min. 100 kHz Hiccup technique, auto-recovery Zener diode clamp Hiccup mode, indefinite (automatic recovery) 3000V 1500V 500V -25C...+70C (with derating) -40C...+85C 0.02%/C 95% RH >200,000 h @ 25C (MIL-HDBK-217F) 2.91 x 2.13 x 0.87 Inches 140 g Free air convection UL/cUL, CE, TUV EN 55022 class B EN 55024 All specifications valid at nominal input voltage, full load and +25C after warm-up time unless otherwise stated. ANC-12S 15W ANC-15S 15W ANC-24S 15W Max Output Wattage (W) Voltage Frequency (Hz) Input 90-264 VAC or 120-370 VDC Current (Full load) Inrush Current (<2ms) Leakage Current External Fuse (recommend) Voltage (V.DC.) Voltage Accuracy Current (mA) max Line Regulation (LL-HL) (typ.) Load Regulation (5-100%) (typ.) Minimum Load Maximum Capacitive Load Ripple Noise Efficiency Hold-up Time Switching Frequency Over Power Protection 12V 1250 15V 1000 24V 625 Output 73% 73% 77% Protection Over Voltage Protection Short Circuit Protection Input-Output (V.AC) Isolation Input-FG (V.AC) Output-FG (V.AC) Operating Temperature Storage Temperature Environment Temperature Coefficient Humidity MTBF Dimension (L x W x H) Case Material Weight Cooling Method Agency Approvals EMI (Conducted & Radiated Emission) EMS (Noise Immunity) ( 74.0 x 54.0 x 22.0 mm ) Tolerance 0.5 mm Physical Plastic resin with Fiberglass (flammability to UL 94V-0) Safety EMC http://www.archcorp.com.tw TEL: +886-2-26989508 FAX: +886-2-26981319 -1- WWW.ASTRODYNE.COM 300 Myles Standish Blvd., Taunton, MA 02780 Ph: 1-800-823-8082 Fax: 508-823-8181 VER : A_0 update : 94.03.21 1 5 Wa t t U l t r a m i niature Modular Switching Power Supplies ANC SERIES ELECTRICAL SPECIFICATIONS Model No. ( Dual* * riple Output ) T ANC-5D 15W 47-440 Hz 280 mA max. (115 VAC) / 170 mA max. (230 VAC) 10 A max. (115 VAC) /20 A max. (230 VAC) 0.75 mA max. 1.5 A slow blow type 5V 2% 1500 0.5% 3% 0% 470-23,000F depending on model <0.2% Vout +40mV max (Vp-p) <0.5% Vout +50mV max (Vp-p) 71% 15 ms min. 100 kHz Hiccup technique, auto-recovery Zener diode clamp Hiccup mode, indefinite (automatic recovery) 3000V 1500V 500V -25C...+70C (with derating) -40C...+85C 0.02%/C 95% RH >200,000 h @ 25C (MIL-HDBK-217F) 2.91 x 2.13 x 0.87 Inches 140 g Free air convection UL/cUL, CE, TUV EN 55022 class B EN 55024 AC-DC Power Modulei e s ser 15 Watts ANC ANC-12D 15W ANC-15D 15W ANC-5S12D 15W ANC-5S15D 15W Max Output Wattage (W) Voltage Frequency (Hz) Input 90-264 VAC or 120-370 VDC Current (Full load) Inrush Current (<2ms) Leakage Current External Fuse (recommend) Voltage (V.DC.) Voltage Accuracy Current (mA) max Line Regulation (LL-HL) (typ.) Load Regulation (5-100%) (typ.) Minimum Load Maximum Capacitive Load Ripple Noise Efficiency Hold-up Time Switching Frequency Over Power Protection 12V 650 15V 500 5/12 2000/200 1% / 5% 2% / 5% 5V 10% 5/15 2000/150 Output (200 mA) 76% 65% 68% 68% Protection Over Voltage Protection Short Circuit Protection Input-Output (V.AC) Isolation Input-FG (V.AC) Output-FG (V.AC) Operating Temperature Storage Temperature Environment Temperature Coefficient Humidity MTBF Dimension (L x W x H) Case Material Weight Cooling Method Agency Approvals EMI (Conducted & Radiated Emission) EMS (Noise Immunity) ( 74.0 x 54.0 x 22.0 mm ) Tolerance 0.5 mm Physical Plastic resin with Fiberglass (flammability to UL 94V-0) Safety EMC All specifications valid at nominal input voltage, full load and +25C after warm-up time unless otherwise stated. http://www.archcorp.com.tw TEL: +886-2-26989508 FAX: +886-2-26981319 WWW.ASTRODYNE.COM -2300 Myles Standish Blvd., Taunton, MA 02780 Ph: 1-800-823-8082 Fax: 508-823-8181 VER : A_0 update : 94.03.21 AC-DC Power Module 1 5 Wa t t U l t r a m i niature Modular Switching Power Supplies ANC SERIES MECHANICAL DIMENSION ( Top View ) PIN# 1 2 3 4 5 6 7 8 ANC 15 Watts series SINGLE FG AC IN (N) AC IN (L) NO PIN -DC OUT NO PIN +DC OUT NO PIN Dual FG AC IN (N) AC IN (L) NO PIN -DC OUT COMMON +DC OUT NO PIN Triple FG AC IN (N) AC IN (L) -DC OUT COMMON +DC OUT +5V RTN +5V OUT BLOCK DIAGRAM DERATING http://www.archcorp.com.tw TEL: +886-2-26989508 FAX: +886-2-26981319 -3- WWW.ASTRODYNE.COM 300 Myles Standish Blvd., Taunton, MA 02780 Ph: 1-800-823-8082 Fax: 508-823-8181 |
Price & Availability of ANC-15D
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |