Part Number Hot Search : 
32F10 LN513 BPC5010 30PA60C E006945 TECHNO SMBJ22A BDY90S
Product Description
Full Text Search
 

To Download TMXW312 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 SAW Filters
TMX W312
SAW Bandpass Filter - GPS - RF
Specification (Rev 4)
Features................................................................................... P01 Package Drawing & Pin out.................................................... P01 Technical Characteristics ....................................................... P02 Matching Network.................................................................... P02 Nominal Response.................................................................. P03 Maximum Ratings.................................................................... P04 Marking & Packaging .............................................................. P04
TMX W312
SAW Bandpass Filter - GPS - RF
Specification (Rev 4) September 25 , 2005
th
Features
q q q q q
GPS Filter 1575,42 MHz Center Frequency 2,4 MHz useable Passband 50 Single Configuration Ceramic Package for Surface Mounted Technology
Package Drawing & Pin out The product is in conformance with the European RoHs Regulation 2002/95.
Pin Configuration Input Output Case ground B D A, C
1
TMX W312
SAW Bandpass Filter - GPS - RF
Specification (Rev 4) September 25 , 2005
th
Technical Characteristics Reference Temperature : +25C Electrical Parameters Source Impedance (single ended) Load Impedance (single ended) Center Frequency fo Bandwidth at -3 dB Absolute attenuation DC to 1400 MHz 1400 MHz to 1475 MHz 1475 MHz to 1525 MHz 1625 MHz to 1640 MHz 1640 MHz to 2000 MHz 2000 MHz to 3000 MHz Insertion Loss within 1574.22 MHz ~ 1576.62 MHz VSWR within 1574.22 MHz ~ 1576.62 MHz Ripple within 1574.22 MHz ~ 1576.62 MHz dB dB dB dB dB dB dB dB 35 30 25 30 32 32 37 34 37 45 34 34 1.5 1.2 0.1 2.2 2.0 1.0 Unit MHz MHz Minimum 2.4 Typical (1) 50 50 (2) (2)
Maximum -
1575.42
Notes : (1) Typical values are nominal performances at room temperature. (2) No external matching network is required. (3) The amplitude variation is defined as the maximum level - minimum level over the given bandwidth.
Matching Network
2
TMX W312
SAW Bandpass Filter - GPS - RF
Specification (Rev 4) September 25 , 2005
th
Nominal Frequency Response (Measurements) Frequency Response
Frequency Response
3
TMX W312
SAW Bandpass Filter - GPS - RF
Specification (Rev 4)
Maximum Ratings
September 25 , 2005
th
Operating Temperature Range Storage Temperature Range DC voltage between any two pins Input Power Level
C C V dBm
[-40C ; +85C] [-40C ; +85C] 5 10
Marking
LINE 1 LINE 2
Line 1: "P C" with P for the code product identification and C for the partner identifier Line 2: "Y W" with Y for the last digit of the year and W for the week code (A to Z for the week 1 to 26 and a to z for the week 27 to 52.
Packaging 1. 2. 3. Temex label ESD Prevention label Pb free label (if applicable)
3
Scanning Orientation
4


▲Up To Search▲   

 
Price & Availability of TMXW312

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X