If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
36-72VDC INPUT RANGE DC-DC CONVERTER HOT-SWAP CompactPCI QUAD OUTPUT 200 WATTS CURRENT SHARING SWITCHING POWER SUPPLIES TPDC200P-48B SERIES FEATURES: 200W IN 3U X 8HP EUROCARD PACKAGE CompactPCI DC-DC CONVERTER INTERNAL OR-ING DIODES FOR N+1 REDUNDANCY DROOP CURRENT SHARING HOT-SWAPPABLE EMI MEET EN55022/FCC CLASS B CE MARKING COMPLIANCE FULLY COMPLIANT WITH PICMG TOTAL POWER INT'L SPECIFICATION INPUT SPECIFICATION Input Voltage: Typ. 36-72Vdc nominal 48Vdc. Input Connector: Positronic 47-pin PCIH47M400A1. Inrush Current: Cold start 8A @ 72 Vdc. (Active) Input Current: 4.5A @ nominal 48Vdc. Dielectric Withstand: Meet IEC950 regulation. EMI: Meet CISPR EN55022 & FCC Class B. Remote ON/OFF: Available at [INH#] & [EN#] pins. Power Fail Signal: Available at [FAL#] pin. Status LED: OUTPUT SPECIFICATION Output Voltage: See Ratings Chart. Output Current: See Ratings Chart. Output Wattage: Typ. 200W continuous. Output Connector: Positronic 47-pin PCIH47M400A1. Line Regulation: Typ. 0.5% over DC input range. Load Regulation: Typ. 1.0-2.0%. Noise & Ripple: Typ. 1% peak to peak or 50mV, which is greater. OVP: Built-in at VO1 & VO2. Adjustability: Available at VO1 & VO2. VO3 factory set. Remote Sensing: Available at VO1,VO2 & VO3. Hot-Swap: Available. N+1 Redundancy: Installed with internal OR-ing diodes at all outputs for N+1 redundancy operation. Current Sharing: Droop current sharing method for all outputs. Operating Temperature: 0 to +50C at full load with specified air flow. Derates linearly to 50% at +70C. Storage Temperature: -40 to +85C. Temperature Coefficient: Typ. 0.02% /C. Cooling: At least 20 cfm (600 lfm) moving air is required to achieve full rating power. Power Density: 3.7 Watts / Cubic Inch. GENERAL SPECIFICATION Efficiency: Typ. 79%. Switching Frequency: 130 KHz. Circuit Topology: Forward circuit. Transient Response: Peak transient less than 200mV and recovers within 3mS after 25% load-change. Safety Standard: IEC950/ UL1950. Construction: Eurocard 3U x 8HP x 160mm CompactPCI format. Front Panel with either Ordinary handle or Extractor handle. Note: All measurements are at nominal input, full load, and +25C unless otherwise specifications. TOTAL POWER, INT. Tel: 877-646-0900 Fax: 978-453-7395 Email: sales@total-power.com http://www.total-power.com -1- OUTPUT VOLTAGE / CURRENT RATINGS CHART QUAD OUTPUT MAIN +VO1 @ #= MODEL NO. Min. Typ. Volt. Max. +5V +5V 35A 35A AUX. +VO2 @ #= Typ. 10A 10A Volt. +3.3V +3.3V Max. 20A 20A AUX. +VO3 =#(@) Typ. Volt. Max. Peak AUX. -VO4 = Typ. Volt Max. Peak TPDC200P-48B-490(E) 2.0A 25A TPDC200P-48B-490(O) 2.0A 25A 3.0A +12V 5.0A 6.0A 0.5A -12V 1.0A 1.0A 3.0A +12V 5.0A 6.0A 0.5A -12V 1.0A 1.0A Symbol: "" OVP built-in. "@" Adjustable. "(@)" Adjustable factory set. "#" Remote sensing. "=" Droop Current Sharing. "" Installed with Or-ing diode. "" Magnetic Amplifier. "" Installed with Post Regulator. "" Common Choke. Remark: Peak load less than 60sec. with duty cycle <10%. Max. load is the continuous operating load of each rail. But the max. load of each rail can't be drawn from all outputs at the same time. MECHANICAL DIMENSIONS: MM [INCHES] WEIGHT: 666.0g (23.5 Oz.) TPDC200P-48B-490(E) TPDC200P-48B-490(O) INPUT & OUTPUT CONNECTORS PIN ASSIGNMENT DC INPUT ASSIGNMENT -Vin +Vin G CNTR &PIN # 47 46 45 QUAD OUTPUT VO1 1,2, 3,4 S+ 30 S34 VO2 13,14,15,16,17,18 S+ 33 VO3 20 S+ 36 VO4 21 DC COM 5,6,7,8,9,10,11,12, 19,22,24 EN# 27 STATUS/CONTROL DEG# 38 INH# FAL# 39 42 Mating connector: PCIH47F400A1. TOTAL POWER, INT. Tel: 877-646-0900 Fax: 978-453-7395 Email: sales@total-power.com http://www.total-power.com -2- |
Price & Availability of TPDC200P-48B-490O
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |